Home

Manual Viper S

image

Contents

1. can destroy the electric parts of the machine Check the state of the air valve filter from time to time and clean or replace it when necessary Always replace the whole fluid canister rather than pouring new fluid into the old tank This reduces the changes of the machine clogging up If you install the Viper S make 100 sure that a permanent fog free air supply for the unit is guaranteed Cooling air with too high fog concentration very often in Clubs and Discos can condense inside the machine and cause moisture damage For cleaning the surface of the device use a suitable solvent free cleaner PLEASE NOTE The vaporizer of our machines does not have to be cleaned Cleaners available on the market can damage the vaporizer We cannot grant warranty in this case 15 7 Troubleshooting The fog machine does not fog Check external control signals Check mains supply Check fluid tank empty Check for correct connections at the fluid bottle Check for fluid in the fluid tube Check if fluid filter is clogged Check that pump setting on the machine is gt 1 The fog machine fogs uncontrollably Check mains supply e Check unit for moisture moisture inside the machine especially on the PCB can cause fogging The fog machine switches off suddenly The Temperature cutout has switched off due to overheating Remove external heat source for instance projector shining right onto the housing and or make sure sufficien
2. burnt e Occasionally very hot droplets of fluid may escape when in operation Thus never aim at persons directly and keep a minimum distance of 3 m 9 8 ft to the nozzle e Never touch the nozzle when in operation Danger of getting burnt e The location for the machine must be non flammable non combustible and not sensitive to heat It has to be twice as big as the machine e Keep a minimum distance of 60 cm 1 9 ft to all flammable combustible objects and objects sensitive to heat e Glycol is alcohol and burns with a slightly bluish almost invisible flame Never point the fog at strong sources of ignition like fire or pyrotechnic effects e Never open the machine and leave the machine unattended when connected to a power supply e The visibility has to be more than 2 m 6 5 ft in rooms where people walk around e Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor should you have accidentally swallowed some fluid e Spilled fluid or splashed fluid droplets can cause slip hazard Mop up the fluid and dispose of it according to regulations e Fog may activate smoke detectors Artificially made fog can be produced in many different ways The method used here to produce fog with a device which works according to the vaporizer principle is the most harmless one No case has so far been reported in which a sound human being has been harmed be cause of using o
3. is controlled via DMX 512 this data takes priority over 0 10 V DC and Stand alone operation 5 4 1 Operating via DMX 512 Connecting the Viper S to a DMX desk using the 5pin XLR socket 4 on the back of the machine As soon as the machine receives a correct DMX signal the yellow DMX LED 17 shines 5 4 1 1 Adjusting the DMX start address a Press the Mode button 14 at the control panel until three figures will appear on the LED display 18 b Adjust the requested start address by pressing the Up Down buttons 15 c Save the start address by pressing the Enter button 16 once The start address will also be saved when you disconnect the machine from the mains supply 5 4 2 0 10 Volt DC control Connect the Viper S to an analog desk or with the cable remote available as an optional extra using the 3pin XLR socket 3 at the back of the machine a Connect the cable from the desk or the cable remote into the XLR socket at the back of the machine 3 b Put the pump up to 99 by pressing the Up button c The knob on the cable remote or the fader on the analog desk will control the level of the pump d Pressing the On Off switch at the cable remote starts the fog process the green On LED 18 illuminates 11 5 Operating the Viper S 5 4 3 Stand alone The Viper S can be used in the Stand alone mode In this mode the control of the pump must be adjusted at the machine a Press and release the Mode b
4. Operating manual Viper S a Look Solutions product Set of Equipment supplied 1 Viper S 1750 ml 25 3 oz tank incl lid with Quick Connector 1 manual Please check whether all the products you ordered are supplied Contents Introduction Safety instructions Description of the parts Fluid 4 1 General Notes 4 2 Filling the fluid container Operating the Viper S 5 1 Selecting the location 5 2 Putting into operation 5 3 Switching the device off 5 4 Control choices 5 4 1 Control via DMX 512 5 4 1 1 Adjusting the DMX start address 5 4 2 Control via 0 10 Volt DC 5 4 3 Stand alone mode 5 4 4 Control via Radio remote 5 5 Operating with internal timer 5 5 1 Auto start 5 6 Wiring of the connectors Cleaning Care and Maintenance Troubleshooting Specifications Warranty Conditions 15 16 17 18 1 Introduction The Viper S is the perfect addition to the established Viper series The fog output of the machine is amazing although the machine has only 650 Watt Coincidental the Viper S features a low current consumption and also little fluid consumption Thus the cost of operation is low and the machine is energy saving Due to the handy dimensions and the low weight the machine can be transported very easy and can be used nearly everywhere Original manual version 01 2014 2 Safety instructions A fog machine is not a toy e Very hot steam escapes from the nozzle Danger of getting
5. al or mistakes by incorrect handling treating of the machine will lead to a loss of guarantee and also any faults and damages caused by undue force 4 Certain parts of the machine are consumable parts and are not covered by the warranty 5 Guarantee services do not cause an extension of the guarantee time or the start of a new guarantee time The warranty for replaced parts ends with the guarantee time of the whole unit 6 If a defect fault can not be repaired by us in a satisfactory time we will within 6 months after sale of the unit on choice of the customer either e replace the whole unit for free or e refund the lesser value or e take back the whole unit and refund the purchase price but not more than the usual market price at the time of the refund 7 Further claims especially for damages losses etc outside the unit are excluded Other guarantee regulations may be valid outside Germany Please check with your dealer If you should send the unit for service do not forget to remove any liquid from the fluid bottle 18 Konformitatserklarung H EC Declaration of Conformity Technology GmbH Declaration de Conformit Wir we nous OTTEC Technology GmbH Anschrift address adress Bunteweg 33 DE 30989 Gehrden Germany erkl ren in alleiniger Verantwortung da das Produkt declare under our sole responsibility that the product declarons sous notre seule responsibilit que le produit Bezeichnung name no
6. fluid container Disconnect the fluid tube from the lid by retracting the brass collar 7 and removing the coupling 6 Remove the container from the tank housing of the Viper S Unscrew the lid 8 of the empty container fill the container with fluid and screw the lid back on Place the full container into the tank housing Push the brass coupling 6 into the brass collar 7 until you hear a click The brass collar is now locked firmly 5 Operating the Viper S 5 1 Selecting the location The location in which the Viper S is to be operated must be dry be free from dusty or polluted air be free from vibrations be an non flammable place or surface be well ventilated with fog free air keeping the ambient operating temperature between 5 C and 45 C and the relative air humidity below 80 5 Operating the Viper S The Viper S is a powerful fog generator producing every desired effect from a tiny puff of smoke to the thickest fog Digital technology makes fine adjustments of the pump possible In steps of 1 the output can be adjusted from 1 99 5 2 Putting into operation a Connect to the mains supply Make sure the correct voltage is selected 230 V 50 Hz A P and two figures appear on the display After a warm up time of approx seven minutes the Viper S is ready to start The green Ready Led 20 blinks if the working temperature is reached As soon as the final temperature is reached the LED i
7. llumates permanently Adjust the required output via the control panel and press the Enter button 16 once to start the fogging process see point 5 4 Press the Enter button again to stop the fogging process 5 3 Switching the device off a Press the Mode button 14 til OFF appears on the display After 15 seconds the machine will switch off automatically On the right bottom edge of the display a red decimal point appear You can also switch off the machine within these 15 seconds by pressing the Enter button 16 When you switch off the DMX signal the machine will be switched off automatically after 15 seconds 5 Operating the Viper S Control panel Standard Menu 17 DMX LED yellow 20 Ready LED green 19 Timer LED red 18 LED display 15 Up Down buttons 16 Enter button Fig 1 14 Mode button Display shown at adjusting the pump output Fig 2 Display shown at adjusting the DMX start address Fig 3 Display shown at switching off the device 10 5 Operating the Viper S 5 4 control choices Please note You can t use the Mode button for scrolling through the Menu The Mo de button has to be pressed momentarily If the Mode button is pressed and hold more than two seconds the machine will change into the Timer Mode see point 5 5 You may control the Viper S externally through the XLR sockets 3 and 4 Please note DMX takes priority That means when the machine
8. m Nebelmaschine Fog machine G n rateur de fum e Typ type type Viper S mit den Anforderungen EN 55014 Teil 1 Part 1 Generic emission standard der Normen Ubereinstimmt EN 55014 Teil 2 Part 2 Generic immunity standard fulfills the requirements of the standard EN 60335 1 Electrical safety satisfait aux exigences des normes VDE 0700 Teil 245 Part 245 Electrical safety Das Produkt erf llt somit die Forderungen der EG Richtlinie Therefor the product fulfills the demands of the following EC Directive Le produit satisfait ainsi aux conditions des directives suivantes de la CE 2004 108 EG Richtlinie Uber die elektromagnetische Vertraglichkeit Directive relating to electromagnetic compatibility Directive relatives la compatabilit lectromagn tique 2006 95 EG Niedrigspannungsrichtlinie Low Voltage Directive Directive Basse tension Gehrden 01 10 2012 Ort Datum der Ausstellung Name und S chrift des Befugten Place and Date of Issue Name and Sig ature of authorized person Lieu et date d tablissement Nom et signature de la personne autoris e 19 a Look Solutions product
9. machines made in Germany B nteweg 33 DE 30989 Gehrden 17 9 Warranty Conditions For the fog machine Viper S Look guarantee is 1 Free of charge subject to the following conditions No 2 6 we will repair any defect or fault in the unit if it is caused by a proven factory fault and has been advised immediately after appearance and within 24 months of delivery to the end user Insignificant deviations of the regular production quality does not guarantee replacement rights nor do faults or defects caused by water wrong fog fluid by generally abnormal environment conditions or Force Majeure 2 Guarantee Service will be done in the following way Faulty parts will be repaired or replaced our choice with correct parts Faulty units have to be brought to us or our service centres or to be sent to us or our service centres at customer s expense The invoice and or receipt showing the purchase date and the serial number has to come with the faulty unit otherwise this will not be guarantee service Replaced parts become our property 3 The customer loses all rights for guarantee services if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are not approved by us The right of guarantee service is also lost if fluids other than original Look fog fluids have been used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manu
10. output fog time or wait time is the same as in the Standard Menu That means you have to press the Mode button until you reach the required function With the Up Down buttons you can adjust the output Pxx fog time F xx and wait time P xx then press the Enter button to start the timer The timer cycle starts with the time last shown on the display i e P xx Starts with wait time F xx Starts with fog time You can switch back to the Standard Menu by pressing the Mode button 14 for more than 2 seconds or by switching to ESC Escape in the Timer Mode and then press the Enter button 5 5 1 Auto start If the timer is in operation and you disconnect the machine from the mains cable the Viper S will re start in the Timer Mode as soon as it s reconnected to the mains To stop this press and hold the Mode button 14 for more than 2 seconds or switch to ESC in the Timer Mode and then press the Enter button 13 5 Operating the Viper S 5 6 Wiring of the connectors 5pin XLR DMX Pin 1 Ground Pin 2 DMX Pin 3 DMX 3pin XLR analog Pin 1 Ground Pin 2 0 10 V DCin Pin 3 12 V DC out max 50 mA 14 6 Cleaning Care and Maintenance Ensure the air vents are not clogged by dust If necessary remove the dust Take care that the machine can not get overheated Do not run the Viper S without any fluid as the pump will run dry Wipe up spiled Fluid immediately Moisture also fluid
11. t fresh air supply After 15 to 30 minutes the unit should switch back to on again Loud droning sound during fogging The pump is running dry Avoid this absolutely Refill or better replace fluid bottle Double check connection fluid tube and fluid bottle E 4 appears on the LED display The machine is getting too hot The heating switches off and the machine cools down Solution Disconnect the machine from the main supply for a moment and then re connect it E 1 appears on the LED display Please send the machine to the service station or your local dealer 16 E 4 EI Procedure Power requirement Voltage Warm up time Fluid consumption Fluid tank capacity Fog output Output projection Fogging time Control Temperature control Overheating protection Dimensions L x W x H Weight without tank Manufactured for 8 Specifications vaporizing fog generator 650 Watt 230V 50Hz or 120 V 60 Hz approx 7 min 60 ml 2 0 oz min at max output 15 ml 0 5 oz min at continuous output 750 ml 25 3 oz adjustable in 99 steps steps a 1 max 8 m 26 2 ft at 100 output approx 22 sec at lt 25 output continuous output DMX 512 0 10 V analogue Timer Stand alone mode Radio remote option XLR remote option Microprocessor controlled Heater block with thermostat Pumpe with temperature switch 35 x 18 x 19 cm 13 7 x7 x 7 5 in 5 4 kg 11 9 lb Look Solutions Fog
12. ur device to produce artificial fog However this can only be guaranteed if the professional fog generators are used accordingly i e at the correct vaporization temperatures as well as with the correctly mixed fog fluid We however recommend People with health problems or problems of the respiratory tract or with an inclination for allergies should avoid any contact with artificially made fog 3 Description of the parts Front view 1 Nozzle Rear view 2 Control panel for adjusting the DMX start address and the output 3 XLR socket for 0 10 V DC 4 DMX in out 5 Brass collar for fluid tube 3 Description of the parts Tank lid ES 6 Brass coupling 6 7 Brass collar 8 Tank lid a 9 Check valve 10 Fluid filter 8 4 Fluid 4 1 General Notes The Viper S has been designed to be used with Look fog fluids The following Look fog fluids are available Quick Fog thick quick disappearing fog fluid Regular Fog thick long lasting fog fluid Slow Fog thick extremely long lasting fog fluid If fluids have been used other than Look fog fluids we can t grant warranty on parts that have been in contact with the fluid PLEASE NOTE The vaporizer of our machines does not have to be cleaned Cleaners available on the market can damage the vaporizer We cannot grant warranty in this case 4 2 Filling the
13. utton 14 until a P and two figures appear on the display 18 b Adjust the pump output with the Up Down buttons 15 and press the Enter button 16 once to start the fogging process The machine now produces fog until the Enter button is pressed again The output can be changed during the fogging process 5 4 4 Control via Radio remote A radio remote is available as an option It will be delivered with a 3pin XLR plug Connect the receiver of the radio remote to the machine using the 3pin XLR socket 3 on the back of the machine Adjust the requested pump output at the machine see point 5 4 3 Press and hold the first button at the transmitter of the radio remote as long as you want fog to be produced see manual Radio remote Control panel Timer Menu the red Timer LED 19 shines Adjusting of the output pump Adjusting of the wait time in steps of 1 1 99 in minutes 0 1 99 12 5 Operating the Viper S Adjusting of the fog time Escape to switch back to the in seconds 1 99 Standard Menue with the Enter button 5 5 Operating the internal timer With the internal timer the fog time and wait time as well as the output can be adjusted To start the Timer Mode press and hold the Mode button 14 for more than 2 seconds The red Timer LED 19 shines as soon as the machine has switched to the Timer Mode As long as the timer is in operation the red Timer LED blinks The adjusting of the

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  Asrock H61M-S motherboard  MEN Mikro P602 Manual  Cellular Line FRUTTASWEAT1 mobile phone case  USER MANUAL OF FELIX 0.2 - The Stanford University InfoLab  Instruction Manual for Kick Starter Arm  5月10日(PDF:1153KB)  MX8 User`s Guide - Honeywell Scanning and Mobility  Edital republicado RP 105 7075 2011 RP PSDM  HP laserJet Enterprise 500 MFP and LaserJet Enterprise Flow MFP  