1.       CALYS 50    Field multifunction calibrator for basic  use    CALYS 50 field multifunction calibrator is the perfect tool for advanced  process maintenance and use on test bench in all industries  Suitable for all  field and lab measurements  it can simultaneously measure and generate  over two isolated channels various signals of temperature  resistance   process and frequency in one single instrument     SD 1928    OJD CALYS 50  i 19 01 2015    Description    CALYS 50 is a basic multifunction calibrator within CALYS range  It is the perfect tool for  advanced process maintenance and use on test bench in all industries  Suitable for all field and  lab measurements  it can simultaneously measure and generate over two isolated channels  various signals of temperature  resistance  process and frequency in one single instrument     It provides extended functionalities  temperature simulation  scaling  steps  synthesizer   statistical functions      easily accessible through quick menus by function     The instrument simultaneously measures and simulates     e Temperature  Up to 0 014  RDG   e Resistance  Up to 0 012  RDG  4 KQ range   e Current  Up to 0 0175  RDG  50 mA range   24 V loop supply   e Voltage  Up to 0 013  RDG  50 V range   e Frequency  Up to 0 005  RDG  20 KHz range  10 KHz in simulation     IP 54  fully protected by an antichoc rubber holster  CALYS 50 integrates  easyconnect   terminals and a wide backlite display that makes it easy to use in any severe or 
2.  Res  Accuracy   lan Nota  lext  40 Q 1 mQ 0 014  RDG   3 mQ 10 mA    0 014  RDG   10 mQ 1mA    400 Q 10 mQ 0 014  RDG   20 mQ 10 mA  0 014  RDG   30 mQ 1mA    4000 Q 100 mQ 0 014  RDG   300 mQ 0 1 1 mA    Temperature coefficient   lt  5 ppm   C beyond reference domain  Current establishing time   lt  1 ms  lext  Current received by the calibrator    Further features       50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38 8              Scaling in measurement and simulation modes    Relative measurement    Simulation menu  Square root  Statistical functions    Ramps generation    Steps simulation    Synthesizer    Transmitter function    CALYS 50    19 01 2015    Scaling allows process signals to be displayed in    of FS or in all other units  This function also  allows sensors to be corrected after a calibration     The features allows the following      e Programming a reference value  different from the one of the  instrument  NUL function     e Subtracting of constant value by  measuring or programming it from a  measured value  TARE function      Simulation value is set by entering value on  keypad or by changing the specific digit with the  cursor     In current measurement and simulation  this  function allows taking into account a quadratic  signal coming from transmitter of type AP     Continuous display of average  minimum and  maximum value of the signal under monitoring  as  well as number of measurements     Starting 
3.  ending and length time values of simple  or cyclic ramps can be set to do simulation   Number of ramps can also be adjusted in case of  cyclic ramps for any signals     2 modes are available     e Program mode  Starting value  number  of steps and the length time have to be  set   e Manual mode  User has about a  hundred preset values    In current simulation  user will have some  additional preset values in function of range  and according to 0   25   50   75  and  100  from selected gauge  Choice is done  between gauges    0 20 mA  linear or quadratic   4 20 mA  linear or quadratic    With 100 values manually set  CALYS 50 enables  users to draw a generation curve     CALYS 50 is able to be used as a transmitter   Measurement input is copied on the output with  scaling     50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38    General specifications    Size  Weight  Display    Power supply    Battery  Communication ports    Environmental specifications    Reference range  Operating reference range    Limit operating range    Storage temperature limits  Maximum height    IP protection    Safety specifications    Protections    Class    Rated voltage  Chocks and vibrations    EMC conformity    CALYS 50    19 01 2015    210 x 110 x50 mm  900g    240 x 320 pixel liquid crystal graphical display  with backlite and contrast control  Display of result as table of values or trend curve    230 V   10    50 60 Hz    Type   Temps de charge 
4.  h  Endurance   5 000 mesures    10 A    USB    23  C   5  C  RH  45 to 75   w o condensing    10 to 50  C  RH  20 to 80   w o condensing      15  C to  55  C  RH  10 to 80   w o condensing    70  at 55  C      30  C to  60  C  0 to 2000 m  IP54 according to EN60529    e Electronic protection up to 250 V for     voltage    wires   e Fuse protection for    current    wires   e Protection against    current    circuit  breaking during inductive resistance  measurements    In accordance with EN 61010 1  Category Il  pollution 2    60 V  EN 61010 1    Immunity     e EN 61000 4 2  EN 61000 4 3  EN 61000 4 5  EN 61000 4 6    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38 10              e EN 61000 4 11    EN 61000 4 4  Conducted and radiated emissions     e EN 55022  class B    e EN 61000 3 2  e EN 61000 3 3    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38    CALYS 50    19 01 2015    11    OJD CALYS 50  i 19 01 2015    Models and accessories    Instrument   CALYS50 On site documenting multifunction calibrator    Delivered in standard with     User manual   Battery charger   Set of 6 testing leads  Carrying strap  Factory test report    Accessories   AN6050 Transport case for CALYS series  ACL9311 Set of 6 measuring cables with removable crocodile clips    ER 49504 000 USB cable    Certification   QMA11EN COFRAC certificate of calibration    With all relevant data points where the dev
5.  treatment AMS    2750    Advanced data exploitation  Scaling  relative measurement   simulation of ramps and steps  synthetizer  square root  statistical    functions  Transmitter function    Switch test  Calibration of transmitters    Comparison calibration  HART  Digital calibration and    data transfer    Calibration of thermistors    DATACAL calibration software for configuration    and data management    10 000 data stored and recalled on screen as    curve or list    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38    CALYS 50    19 01 2015    Specifications    Specifications and performances in temperature  23  C  5  C  Uncertainty is given in   of reading  CALYS 50 display    fixed value     Resistive probes  Measurement and simulation       Sensor Range  Input Resolution Accuracy   1 Accuracy   1  and Output  year year   Measurement   Simulation   Pt50  a   3851   220  C to 0 01  C 0 012  RDG   0 014  RDG    le OORE 0 06  C onge  Pt100  a   3851    220  C to oronge 0 012  RDG   0 014  RDG     1200  C 0105    0125     Pt100  a   3916    200  C to  510  C   0 01  C 0 012  RDG   0 014  RDG    0 05  C 0124     Pt100  a   3926    210  C to  850  C  0 01  C 0 012  RDG   0 014  RDG    0105    OnE  Pt200  a   3851    220  C to  600  C  0 01  C 0 012  RDG   0 014  RDG    OMG 033     Pt500  a   3851     220  C to 080086 0 012  RDG   0 014  RDG    cle OORE 01072 0182     Pt1000  a   3851     220  C to 0 01  C 0 012  RDG   0 014  R
6. 2C    08586    OJD CALYS 50  l 19 01 2015     660  C  600  C   E  200 to OLO52E 08226  200 to 0 05  C 022      900  C  900  C      20 to OnE 0252     20 to 08086 02580   900  C 0 1  C 0 013  RDG  900  C OLE 0 013  RDG   900 to   0 15  C  900 to   0 15  C  2B 102C 2310  C   N  240 to ORE ODE  240 to 06286 0 3  C   190  C ONE OMS 2E  190  C OE LSG   190 to 0 05  C 0 08  C  190 to 010526 0 08  C   110  C 01052 0 013  RDG    110  C 0 052    0 015  RDG   110 to  0  C   0 06  C  110 to  0  C   0 06  C   0 to  0 to   1300  C  1300  C   Platinum  100 to 0105    08326  100 to 060058  06396   1400  C  1400  C   Mo  0 to 01052 0 013  RDG  0 10 01052 0 013  RDG   1375  C   0 06  C  1375  C   0 06  C   NiMo NiCo  50 to OLO52E 0 013  RDG  50 to O1052E 0 013  RDG   1410  C   0 30  C  1410  C   0 3  C    Thermocouples  D and G  for specifications  refer to the instruction manual  Available on  request    Accuracy is given for reference   0  C    When using the internal reference junction  except couple B  add an additional uncertainty of  0 2   C at 0   C    It is possible  thermocouple B excepted  to choose by programming the cold junction  localization  External at 0  C  internal  temperature compensation of instrument   s terminals  or  manually entered    Temperature coefficient   lt 10  of accuracy    C   Display unit    C and F    Specifications and performances in process  23  C  5  C    DC current  Measurement  With or without loop supply    Range Res  Accuracy   lan Rin   0 20 mA 1 
7. 805526    05226   0 05  C  0105     0 05  C    0105     0105     0 05  C    OnE   0 05  C  0 05  C  0 05  C    One    O 052       Accuracy    1 year  Me  asurement     0 8  C  0825 26  OMG  0 013  RDG    00896    05      6  0825526  OnE  0 013  RDG    0 08  C    0825 26  0 09  C  0 013  RDG  ar 0072C    0 45  C  00526  0508 26  0 013  RDG  T 005E    06886  0 013  RDG  ap OSHE  0 013  RDG  ap O  72 XE    0 80  C  0 013  RDG  oP  815  1C  0 013  RDG  10252    0 013  RDG    0 4  C  0 013  RDG  ap O2    08596    Output  range     240 to   50  C    50 to  0  C   0  C to   1372  C     240 to   100  C   100 to  0  C   0 to   400  C     210 to  0  C   0 to   1200  C     240 to   100  C   100 to   40  C   40 to  1000  C     50 to    350  C   350 to   900  C   900 to  17 682        50 to   120  C   120 to   450       450 to   1768  C     400 to   850  C   850 to   1820  C     200 to    Resolution    025    0 05  C    06226  00056  0 05  C    01052     0 05  C    OnE  OnE  0 05  C                       C   E                i     E   N    OEE    0 05  C    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38    CALYS 50    19 01 2015    Accuracy    1 year   Simulation       00606   One  0 013  RDG    0 08  C    0 4  C   Once  0 013  RDG    0 08  C    Ore  0 013  RDG  tO  OME    025C  OnE  0 013  RDG  t 01052C    052     0 013  RDG    03526  0 013  RDG  Ona    0182     0 013  RDG  02526  0 013  RDG  0252C    0 013  RDG    0 4  C  0 013  RDG  ar 0
8. DG    1200C OLS aE 0 08  C  Ni100  a   618   60  C to 180  C oronge 0 012  RDG   0 014  RDG    OLO32E 0 08  C  Ni120  a   672   40  C to  205  C ORO E 0 012  RDG   0 014  RDG    0 03  C 0 08  C  Ni1000  a   618     60  C to  180  C 0 01  C 0 012  RDG   0 014  RDG    OLOS2E 0 08  C  Cul10  a   427   50  C    to 150  C OLO1EE 0 012  RDG   0 014  RDG    0 18  C OE  Cu50  a   428     SOLE tor 0E ORO E 0 012  RDG   0 014  RDG      0 06  C    0715       Resistive probes measurements in 2  3 or 4 wires  automatic recognition of number of    connected wires  with indication on screen   Accuracies are given for 4 wire mounted probes   Take into account particular error of temperature sensor used and implementation conditions  Measuring current  0 25 mA  Measurement  or from 0 1 to 1 mA  Emission    Temperature coefficient   lt  10  of accuracy    C    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38           Ip    Thermocouples  Measurement and simulation       Type    Input range Resolution     250 to   200  C    200 to   120  C    120 to  0  C  0  C to   1372  C     250 to   200  C   200 to   120  C   120 to   50  C    50 to    400  C     210 to   120  C    120 to  0  C   0 to   1200  C     250 to   200  C   200 to   100  C   100 to  0  C   0 to   1000  C     50 to    150  C   150 to   550  C   550 to  1768  C     50 to   150  C   150 to   550  C   550  to   1768  C     400 to   900  C   900 to   1820  C     200 to    MZE    0 05  C  0
9. dark conditions     Easy connection system       Connect your probes by simply pushing on the terminal top and insert  wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors     Wires are held tight between two brass plates ensuring thermal stability and a very good cold  junction compensation for thermocouples     This system also enables 4 mm banana plugs and security connectors to be connected on the  terminal top     CALYS series  4 models from basic use to advanced  performances    Specifications CALYS 50 CALYS 75 CALYS 100 CALYS 150  Top accuracy 200 ppm 130 ppm 50 ppm  Temperature Thermocouples 0 013  RDG for Tc K 0 01  RDG for 0 005  RDG  accuracy  14  0 012  RDG Tc K for Tc K    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38 2              RTDs  12     DC current Range    Loop supply   Accuracy  24V    DC voltage Range  Accuracy  Frequency Range  Accuracy  Resistance Range  Accuracy  Pressure Range  Accuracy    Compliance to standards    Additional functions    Additional functions    Additional functions    Software    Memory    CALYS 50    19 01 2015    0 006  RDG    100 mA  0 007  RDG    50 V  0 005  RDG    100 KHz  0 01  RDG    50 KO  0 006  RDG    0 01  RDG  50 mA  0 0175  RDG  50VIN 20V 50V  OUT 0 010  RDG  0 013  RDG  20 KHz IN   10 KHz OUT  0 005  RDG  4000 Q 4000 Q  0 012  RDG 0 010  RDG  Relative pressure  30 bar   Absolute pressure   1 000 bar  0 05  RDG    ZEERERaneeel    NADCAP Heat
10. ice has been tested    Packing information   Size 210 mm x 110 mm x 50 mm    Weight without packing 900g    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38    
11. inuity test  Open circuit for R  gt  1000 Q and closed circuit for R  lt  1000 Q  Measurement current  0 25 mA    DC current  Emission       With or without loop supply    Range Resolution Accuracy   lan   24 mA 1 pA 0 0175  RDG   2 pA  4 20 mA 1 pA 0 0175  RDG   2 pA  0 20 mA 1 pA 0 0175  RDG   2 HA    Temperature Coefficient  lt  10 ppm   C beyond reference domain  Settling time   lt  5 ms  Specifications given for CALYS configurations in     50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38 7    OJD CALYS 50  l 19 01 2015      Active mode   24V ON  1 Meter in passive mode   24 V OFF     Passive mode   24 V OFF  1 Meter in active mode   24 V ON   Pre programmed steps   0  25  50  75  100        4 20 mA linear 4 8 12 16 20   0 20 mA linear 0 5 10 15 20   4 20 mA quad 4 5 8 13 20   0 20 mA quad 0 1 25 5 11 25 20   4 20 mA valves 3 8 4   4 2 12 19  20  21   DC voltage  Emission   Range Res  Accuracy   lan Min load  100 mV 1 uv 0 013  RDG   3 uV HKO  2V 10 uV 0 013  RDG   20 uV 2 kQ  20 V 100 uV 0 015  RDG   200 uV   4 kO  50 V 1 mV 0 015  RDG   2 mV 4 kQ    Noise  3 ppm  for 0 1 Hz to 10 Hz  and 5 ppm  for 10 Hz to 100 Hz   Temperature coefficient   lt  7 ppm   C beyond reference domain  Settling time   lt  5 ms    Frequency  pulse  Emission       Range Resolution Accuracy   lan  1000 Hz 0 01 Hz 0 005  RDG  10 kHz 0 1 Hz 0 005  RDG    Temperature coefficient  lt  5 ppm   C beyond reference domain    Resistance  Emission       Range
12. pA 0 0175  RDG   2 pA  lt 25Q  4 20 MA 1 pA 0 0175  RDG   2 pA  lt 25Q   50 mA 1 pA 0 0175  RDG   2 pA  lt  2510    Temperature coefficient   lt  10 ppm   C beyond reference domain  Loop supply  24 V  10    HART   compatibility  Input impedance Rin   280 Q   Display with linear or quadratic scaling    50 52 Avenue Paul Langevin  F 91130 Ris Orangis   T  l    01 69 02 88 88   Fax   01 69 02 04 38    l 19 01 2015    DC voltage  Measurement       Range Res  Accuracy   lan Rin   100 mV 1 uV 0 013  RDG   3 uV  gt 10MQ  1V  1  10 uV 0 013  RDG   20 uV  gt  10 MQ  10 V 100 uV 0 015  RDG   200 uV   gt 1MQ  50 V 1 mV 0 015  RDG   2 mV  gt  1 MQ    Temperature coefficient  lt  7 ppm   C beyond reference domain   1  Specification domain   0 8 V to  1 V    Frequency  counting  Measurement       Range Resolution Accuracy   lan  20 kHz 0 01 Hz 0 005  RDG    Temperature coefficient  lt  5 ppm   C beyond reference domain  Scale unit  Pulse   min and Hz   Trigger level  1 V   Measurement on frequency signals or dry contacts   Counting will be performed on defined time or infinite time     Resistance  Measurement    Range Resolution Accuracy   lan  400 Q 1mQ 0 012  RDG   10 mQ  400 Q 10 mQ 0 012  RDG   100 mQ    Resistance measurement in 2  3 or 4 wires  automatic recognition of number of connected  wires  with indication on screen   Accuracies are given for 4 wire mounted probes   Temperature coefficient   lt  7 ppm   C beyond reference domain   Open circuit terminal voltage   lt  10 V   Cont
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
EndNote Handout ITC  Samsung XL2370HD Vartotojo vadovas  Bedienungsanleitung Operating Instructions    User Manual - Sensor Platform EVK  TANDBERG CODIAN MSE 8220 User's Manual  アフターサービス  Detector Extreme de Seben Manual de instrucciones  Ultra Mini GSM Bug User Manual (SBRGSMB)  Guía de instalación 2 Conecte    Copyright © All rights reserved. 