IPL Treatment System
Contents
1. Dal SONU Ake IS re OHR 11 Oe ee ee cia Ree shine ee A E ae ee ee 15 o ssccccscsccccscsccccscsccccscsccccscsccocscsccccncsccccncsccccscsccccscsccocncsccccncsccocscsscccscsscccscssossnees 16 Al BEOIe CH Ve Seren een ee ea 17 IA NNN TS AE EI E OR E EURE E E A EEE A E DENE E EEA T T 17 4 3 Order the accessory ueeeeeeeeeeeeeeeeeeeeeensnnnnnnnnnnnnnsnnnnnnnnnnnnnnnnnnnnnnnsnnnnnnnnnnnnnnnnnennnnnssnsssssssnsnnsnnsnenennnnsnnnnn 17 This chapter introduces main parts of IPL the control system and parameters 1 1 Specifications Model HM IPL B2 Spectrum range 420 1200nm 510 1200nm 560 1200nm 640 1200nm Option 585 1200nm 690 1200nm 755 1200nm Energy density 10 50J cm2 Pulse sequence 1 2 3 4 5 pulse adjustable Pulse intermission 5 60ms Pulse width 2 15ms Repeat frequency 0 3 1Hz Delivery Sapphire Coupling Light spot 8x40mm2 Option 15x50mm2 Cooling system Water cooling forced air cooling and semiconductor cooling Cooling temperature 4 0 C Power supply 220V 50Hz or 110v 60Hz Net Weight 31kgs Size 490mmx320mmx600mm Gross Weight 42kgs Size 570mmx380mmx680mm 1 2 Parts and control Host Control panel Kelle The IPL treatment Ts head gt The IPL treatment system is mainly made up of the following parts Host Control panel The IPL treatment head This machine holds the micro processor which can continually to supervise and control the working of the system 1 3 Machine box
2. Machine box is the heart of IPL system It includes the following parts Power supply module Supply power to other module and cut off power when the system has malfunction The control module Control and assort with the whole module of system The display controller Display various information of the system and accept the instruction of users High voltage power supply Supply electricity to capacitance Capacitance Store energy that intense pulse light needs The Simmer power light the lamp and keep it in simmering state Cooling system Cool the IPL treatment head A N Caution Only the authorized engineer of the HUAMEI company can open the back cover board and maintain each internal module of this machine 1 4 Control panel The operator controls the system through the control panel which includes the following parts Key switch To be used to turn on and off the power supply Emergency Switch pressing this switch will shut off the whole power supply of system immediately It has priority over the system performance compared with the key switch Follow the arrowhead direction turn the emergency switch clockwise and immediately loosen it otherwise the machine will be kept on shut off The LCD The operator exchanges information by the LCD The system state operation interface hints and instructions are all on the LCD 1 5 The IPL treatment head The IPL treatment head contains electronics components emitting intense
3. treatment head was order bright Can emit light at this time Counter Record the shooting times after switch on each time After the treatment please put back head in the holder let the system return the Menu screen then switch it off by power key Danger 1 While entering the working interface The IPL head must aim at the target skin then the trigger switch shall be activated 2 When a stop is needed press SIMM to switch to Await orders This is in order to avoid touching trigger switch by accident and injuring the patient s eyes 3 No matter whether there is light output or not the IPL head can not aim at anybody 4 It s not allow to aim at light at frangible such as eyes etc Chapter 4 Accessory The accessories of this machine include e Protective glasses Eyepatch 16 Gel e Power cable e Funnel e Pipe e User s manual e CD 4 1 Protective glasses The protective glasses of the IPL can protect the eyes of the operatorsand patients 4 2 The Gel The gel is used to conduct the light and cool off the skin there are six bottles per box 250 grams per bottle 4 3 Order the accessory This machine has a complete set of accessories If the customer needs more accessories please order them from the dealer 17
4. IPL Treatment System User s Manual WeiF ang Huamei Electronics Co Ltd Chapter 1 System elucidation s sssesssesssessseosssosssosssesssesosessseosssosssosssesssesosesssesssessssosssosssosssesssessse 2 lol SDES IC ON a A AE E E O ee 2 Pae A on a tensed ee een 2 Io Machine WOK ee ae ee een innen 3 TS GME ON pane OWEN EEE REN E rir ea aiaa 3 My Te ET ee es re ern em rei 3 KO SySei io anne een A EATE 4 1 7 The environment requirements ccccccccccccccccececeeeeeeseesseseeeeeeeeeeeeeeeeeeaeeeeeeesseeeeeeeeeeeeeeeeeeeeeaeeeeneees 4 Chapter 2 Installation and Debugging ssscsssesssesssesssesssessssosssosssosssesosesssessseosssosssosssosssesssessso 5 2 1 Pompen Ce PA euere 5 2 2 Installation requireMenttS ccccseseeesssssesseeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeeaaaeeeeeeeeeeeeeeeeeeeeeeeeaaaaaeaeeeees 5 DD MESO ICC ROQUCSE EEA I A E TE TA E A T A T 5 22 2 Nee CER all regure MENS es sende een nein nie 3 223 Ey OPM Te gr NTN nenne see 6 253 1081 A100 2 ee A Renee ee 6 24 Replace 1 153 4 175 OURPRIURONEEREUENELEIENUERNELLUEUE EHE BERBEHEEUREAUEEETEUHNENETEN aos iniinis i ndera n anaiita RER 8 2 3 10 aT the TE een ee eu E ne 9 BE 200000000000000000000su00nansonnnnuuonanuonnnnunonanunonsnsonanunnnnssonanunonsnsonannunonensonnnnnonansonnsnnonansnnnsacen 11 3 1 Software operation explanation cccccccccecccecccecceeececeeeaeeseeesseeeeeeeceeeeeeeeeeesaeaeassessesseeseeeeeeeeeeaaaas 11
5. ed to provide the saved treatment parameters displays the current energy value The system state displays the system state the red shows that the system has not been started or is in trouble the yellow shows that the system is under preparation the green shows that the system is ready in the meantime if you step the foot switch the system will shine for treatment displays the energy value The key for energy output adjustment is to be used to increase or decrease the energy The cooling system meter displays the cooling intensity of the system The key for cooling system adjustment lis to be used to increase or decrease the cooling intensity of the system displays the total shots of the lamp displays the current shots of the lamp after switching on the machine Reset the current counter is to be used to clear the current shots number of lamp after switching on the machine displays the current treatment parameters when touching this area the system enter the adjustment to the treatment parameters interface The key for start amp stop to touch this key the system try to light the lamp touch this key again and the lamp is switched off when the lamp is ignited if this key is touched the system will enter pause state meantime if you press the manual switch or the foot switch the treatment head will not flash but the lamp is still on During this time you can adjust the energy and cooling The key for return t
6. ge the electric wire the electric component and optical component surfaces The dust in the air should be as little as possible or it can absorb the energy of light and be heated up When the dust falls on the surface of the filter it may damage the filter Metal particles also could damage the electric component Temperature In order to guarantee the IPL system in the best working state the indoor temperature should be kept at 20 C 25 C relative humidity should be less than 80 The working power of this machine is about 2 KW therefore it is better for the treatment room to have air condition installed 2 3 Installation Take out the machine from the box and place it carefully in the appointed room where the indoor temperature is at 10 C 28 C and the humidity is not over 80 Keep the operation room and treatment bed clean all the time Screw off the water infusion plug Notice use infusion plug with hole during operation use infusion plug without hole during transportation Infuse distilled water from the water infusion hole until the water line reaches the 2 3 place of the water level observation window Install the treatment head Requirement keep the connection part dry and install it correctly Link the power supply Switch on After completing the above installation insert the key and turn it left the machine is switched on at once at this time water begin to circulate and the cooling system starts au
7. n the head at this time then can carry on the treatment After a shot the number of counter will add one the system starts recharged automatically repeating the above mentioned process 3 To check the cleanness of the filter If it looks unclear please wipe with wet soft cloth 4 spread gel of 2 3mm on the treatment area The intense pulse light will be conducted into the skin through gel which should be spread before treating 15 5 Hold the treatment head vertically on the skin press lightly the treatment head should get in touch with gel well 6 Press the button to shoot an intense pulse light the system will refresh again automatically it takes about 2 seconds 7 Wipe off the gel check the treated skin to evaluate patient s instant reaction 8 Treat the next skin area and allow 1mm between the next area and the treated one 9 Record the treatment parameters to provide information and reference for next treatment Caution We suggest the patient return the hospital to check after several weeks In order to confirm if treatment is needed to continue After the treatment use soft cloth with alcohol to clean the treatment head gently Await orders After pressing SIMM The system enters waiting state The intense light lamp in the IPL treatment heads turned off can t shoot the intense pulse light at this time After pressing the STR again The system enters the working interface The intense light lamp in the
8. nfuse distilled water into the water tank Connect the power supply Test all functions of the IPL Install and use 2 1 Equipments detailed list The following is the detailed list of equipments of this machine Host The IPL treatment head Protective glasses Gel The plastics cover of filters Funnel Pipe Power wire Manual DVD 2 2 Installation requirements Before tearing down the packing of the IPL system should check whether the position conform to the requirements of this chapter 2 2 1 Space request The IPL system should be kept away from the hot place with a draught and should be kept a distance over 60 cm from other objects It s good for avoiding radiation and collision 2 2 2 Electrical requirements Before the IPL leaves the factory it has already been marked the local rated voltage according to the customers request It corresponds to the electricity requirement as follows AC220V 10 10A 50Hz or AC110V 10 16A 60Hz Input electric current can t have momentary change electric voltage or electric current peak sink The HUAMEI Company strongly suggests that the IPL system use separate wire and air switches The main safty device in the machine is the 10 A chopper Caution Please confirm the voltage AC220V or ACIIOV that you use agrees with the rated voltage of IPL system 2 2 3 Environment requirements Air quality No caustic particle such as acid in the air which can dama
9. o the last interface if you touch this key the system will return to the last interface Parameter display amp adjustment To show the treatment parameters of current treatment mode Adjust the treatment parameters 13 Adjustable treatment parameters area Pulse cycle the parameter to Save the storage area amp return The keyboard is for the parameter adjustment area to be used to adjust the pulse number between 1 and 5 to be used to adjust the pulse cycle between 1s and 4s after adjusting the parameters if you don t want to save please exit from the interface after adjusting the parameters save them in and exit from the interface Firstly please touch the Adjustable treatment parameters area the digital get underlined to show that this digital is adjustable and then touch the digital key board and set the parameters and last touch the digital underlined again the setting of the parameter is finished First pulse width When single pulse is used the time it takes is regarded as the pulse width when multi pulse is used it width is the first pulse width Adjust range 1 20ms when increasing a pulse its pulse width should be increased by 0 1ms First pulse delay The interval between the first pulse and assistant pulse second pulse range 10 60ms when increasing a pulse its pulse delay should be increased by 14 1ms Second pulse width Assistant pulse width
10. ove steps then start the system 3 Use the distilled water or purified water only The water temperature can not be lower than 5 degrees centigrade 2 5 Installing the filter lf you choose the hand piece with interchangeable filters Please install the filter as following pictures pay attention to the direction of the filter i e the direction of the arrow on the head should be in the direction of the arrow of the filter A N Attain Maybe it is caused by incomplete connection between the filter and the head if the cooling effect of the filter is not good You can improve it as the instructions of the following pictures please loosen the screw on the filter and press the filter gently and then screw on the filter tightly Chapter 3 Operation This chapter describes the operation steps of the IPL system A N Warning There is high voltage in the IPL please make sure all front panels are well covered When the IPL starts please place the treatment head in its holder All personnel need to wear protection glasses or eye patch in the treatment room Even wearing the protective glasses do not look straight at the intense light emitted from the treatment head The treatment head shall not point to any other place besides the target Excessive energy toward the area to be treated may hurt skin 3 1 Software operation explanation 3 1 Software instruction Switch on the machine and then the optional interface ap
11. pears Language setting Select treatment Hair removal mode Skin Rejuvenation P gmentation Therapy gt Vascular Therapy aid 4 I I Sci ee Bw u N Instruction to set the language of the system Choose the treatment mode and enter the main menu see the picture below 11 The total counter The current counter Reset the current The energy value counter The energy meter Parameter display amp adjustment The key for start amp stop The key for pause The key for return The key for energy output adjustment The cooling system The key for cooling meter system adjustment to the last interface Instruction The system hint area to show the functions of the system displays that the charge is finished and the system is ready for working wi i BS displays the recharge trouble 7 13 displays the water system is okay displays the water system in trouble the system is in shortage of water or the water current is not circulating smoothly displays that the Xenon lamp shines Ea displays that the simmer fails zor displays the temperature of the system it still shows the temperature of 20 C when the temperature of it is below 20 C Ehi displays that the system 12 temperature is too high and the system has broken off displays the current treatment mode to be us
12. pulse It connects the system through a set of cable there is a filter with filmed at the end of treatment head Pressing the red key on the IPL treatment head can emit intense light which is delivered to the area to be treated through the 8x40 mm filter in the head It is very important to keep the filter clean Inside the IPL treatment head there is the thermoelectricity type semi conductor refrigeration system used to cool down the filter Then the temperature of the skin surface can be lowered down so as to reduce the patient s discomfort 1 6 System program The program of the IPL mainly has four functions Allow the doctor to choose the best characteristic parameters for the patients according to the concrete diagnosis Control the working process of the system in order to prevent unexpected trouble Examine the system energy Choose the treatment ranges 1 7 The environment requirements Working temperature scope 10 C 30C Relative humidity scope lt 80 Atmospheric pressure barometric 86kpa 106kpa The store environment temperature 0 C 55C Power supply AC220V 22V AC110V 11V 50Hz 60Hz 1 Hz Chapter 2 Installation and Debugging The IPL treatment system can be used in the hospitals and the beauty salon Before installation the preparation is very simple The installation process includes Dismantle the packing and place the IPL system in the pre chosen location Check if the whole of system and parts I
13. tomatically Check Observe instrument to make sure that no water leaks If it is leaks shut off the power supply and contact the dealer Add water When the water in the machine begins circulating the water level inside will drop so you should add some water to the 2 3 place of water level observation 2 4 Replace the water Replace the water inside every 2 to 3 months and please do it according to the following steps strictly Drain water in the machine Screw off drain plug lift up the front of the device to drain water completely Infuse water again following the above mentioned steps Link the power supply according to the above mentioned steps Attention 1 In order to guarantee the safety of operation please increase the distilled water up to 2 3 place of the water level 2 Please use the distilled water not pure water only 3 if the machine has been in the room with its inside temperature below OC for a long time there may be frost inside the machine and the machine may be damaged Method place the machine in a room with a temperature at 20 C for 24 hours then you can carry on operation AN Caution 1 In order to guarantee the machine operated safely please increase the distilled water to the cooling system in time We are not responsible for the damage to the treatment head because of the shortage of cooling water 2 While adding the distilled water for the first time please carry on according to the ab
14. won t be shown when using single pulse range 1 20ms when increasing a pulse its pulse delay should be increased by 0 1ms Second pulse delay The interval between the assistant pulse second pulse and repeat pulse third pulse and the late pulse won t be shown when using a single pulse range 10 60ms when increasing a pulse its pulse delay should be increased by ims Repeat pulse width Repeat pulse the third pulse and late pulse width won t be shown when using single pulse range 1 20ms when increasing a pulse its pulse delay should be increased by 0 1ms Press MENU to enter treatment parameters interface Press Aup for increase or V down for decrease Press ENTER will return to the treatment interface Pulse output First pulse Tl AssistantpulseT2 Repeat pulse T3 First pulse d d First delay Assistant delay Repeat delay Pulse interval The interval is to avoid damaging skin by dividing light to several parts 3 2 Treatment 1 Insert the plug of this machine Insert the key and turn the key around to switch on the machine Almost immediately the Introduction screen is shown it will automatically switch to Picture 2 Then you can choose treatment mode and so on We suggest starting the treatment by using the lower energy density emitting a test light spot to evaluate the patient s reaction 2 After entering the working interface the capacitance starts refresh Press the button o