Home
General Features
Contents
1. a LP Logic Panel m Basic operation flow a electric Requirements for using LP B optie PLC lt Refer to GP editer user manual and SmartStudio gt E Install drawing program GP Editor and KEES logic program Smart Studio on PC Eens lt Refer to communication manual gt E Connection PC with LP body Pressure XWhen LP turns on RUN STOP switch holds SS STOP position Wies g Resilgzeng i E EER Damm e F Rotary encoder lt Refer to the SmartStudio programming manual gt j e SARE Make Logic program with SmartStudio Socket Logic panel is created for integrated panel in most demanding industrial environments that have been a consisted of HMI PLC and I O The LP through integration controller realizes cost down wire reduction space saving and enhanced user friendliness The logic panel perfectly SSRI supports serial communication and editing display with GP geet H Editor and about 250 commands of SmartStudio invented on our own to edit PLC ladder mnemonic allowing accelerating product development and designing And also this device can control and monitor various output devices sensors button etc and output devices solenoid lamp w motor etc individually Create screen or download to LP body m Preparations for using LP LP S044 Disconnect Smart Studio with LP body a Connect GP Editor with LP body Counter Panel meter Test 1 LP body XRUN STOP switch holds RUN posi
2. devices Serial printer SS Autonics m Software GP Editor Drawing program e This drawing software is for GP LP series e GP Editor is the software that allows creating a screen and designs a tag layout and then transfer the data from screen to GP LP After download GP LP starts monitoring according to your screen data SmartStudio Logic program eae e Logic software is for LP series e Support multi project It is possible to open maximum 5 projects at a same time e Easy program editing Block of cell units can be edited Split screen editing is available It provides various editing screens such as variable screen describe screen variable describe screen etc e Various monitor functions It provides monitor functions such as variable monitor device monitor and system monitor time chart e Comfortable user interface It ensures easy operation with Microsoft windows layout e Wide range of Message windows It supports various message windows to edit and check program e Real time convert ladder to mnemonic Ladder and mnemonic can be written and read to edit simultaneously Visit our website www autonics com and download software or manuals lt System requirements gt tem Minimum requirements IBM PC compatible computer with Intel Pentium System Ill or above Operating system Microsoft Windows 98 NT XP Vista 7 Memory 256MB or more Hard disk More than 1GB of free hard d
3. gt GP LP connectable device list will keep updated according to the upgrade of GP Editor or additional patch It is recommended to use the latest version of Editor Applicable GP LP firmware version is determined by GP Editor version Whole GP system goes down if non compatible firmware version is used Visit our website www autonics com to check update of latest GP Editor and GP LP firmware and to get more detailed instructions Refer to the user manual to select proper communication cable between GP and controllers Sold separately Autonics A Photo electric sensor B Fiber optic sensor C Door Area sensor D Proximity sensor E Pressure sensor F Rotary encoder G Connector Socket controller I SSR Power controller J Counter K Timer L Panel meter M Tacho Speed Pulse meter N Display unit O Sensor controller P Switching mode power supply Q Stepper motor amp Driver amp Controller S Field network device T Production stoppage models amp replacement U Other
4. 7 dimension e Please check the pin number and connect to GP LP communication port e Please tighten bolt on terminal block with specified tightening torque e When liquid crystal from the broken LCD is smeared on your skin wash it for 15 minutes If it is gotten in your eye wash it for 15 minutes and contact a medical specialist for more information e Do not inflow dust or wire dregs into the unit e For cleaning do not use water or an oil based detergent use dry towels e t should be done away regarded as an industrial waste R 5 A Photo electric sensor B Fiber optic sensor IC Door Area sensor D Proximity sensor E Pressure sensor F Rotary encoder G Connector Socket H Temp controller SSR Power controller J Counter K Timer L Panel meter M Tacho Speed Pulse meter N Display unit O Sensor controller P Switching mode power supply Q Stepper motor amp Driver amp Controller ll Graphic Logic panel S Field network device T Production stoppage models amp replacement U Other General Features m Connectable device with GP LP Connectable GP LP GP LP MK 1081 CPU direct connection loader LJ b O MK 80S CPU direct connectionloader LJ Jk MK 1208 CPU direct connectionloader LJ Jk E MK 2008 CPU direct connectionloader o JJ MK 3008 CPU direct connection loader o MK 10008 ___ CP
5. General Features m GP Graphic Panel GP S044 GP S070 GP S057 Graphic panel is HMI Human Machine Interface device that parameter monitors or changes via graphic interface by communication with PLC temperature controller or other control units Graphic interface of GP is very effective to indicate value or status of parameter with visual interface that enables the communication between controller and user GP is able to monitor parameters virtually with LCD screen switch screen by touching screen set or change parameters GP connecting with controller via serial communication method translates data and displays various control parameters with graphic For example in case of the target of parameters is the temperate the numerical value of temperature is shown with a tag and the change in temperature for time can be graphed on the screen m Preparation for using GP Graph of temperature The numerical value of temperature 1 GP body 2 PC 3 GP Editor Software for drawing GP screen 4 Manual GP editor user manual LP GP Communication manual GP S044 S057 GP S070 user manual 5 Communication cable Communication cable for PC connection Communication cable for controller connection 6 Access devices PLC or controller built in communication ports wa Basic operation flow Requirements _ Install GP Editor for using GP on PC Design data Connection between with GP Editor PC and GP body lt R
6. Udirectconnectionloader o Jk Lk M4 CPU direct connectionloader LJ Jk M6 CPU direct connection loader LJ Jk GM7U CPU direct connection loader LJ ITT i lt O D LS CNET Cnet integrated CPU LS CNET For Cnet unit ESXGT For Gnetuni xek Pus foe booo Goo SSS TE xm o e ooo p S SSS Chetintegrated cpu ec ng Se xm e oo po o SSS For Cnet unit xo e oo po o oS a wu C A T E e Kee ve CPU direct connection toader LL Oe ae a O OO FX1S CPU direct connection toader LL Exin CPU direct connectionloader LL MITSUBISHI FX EXON CPU direct connection leader 1 Lk Doug CPU direct connectionloader LL FXGU_ CPU direct connectionloader LL aos eg SC or pe ooo p e SSS oe a CC For Cnet unit CC oe eg og EE e ke gen ng kk ke FPO C10 CPU direct connection loader LL FPO C14 CPU direct connection loader LL FPO C16 CPU direct connection loader LL FPO C32__ CPU direct connection loader LL FPG c24R2 CPU direct connection loader LL FPG C32T CPU direct connection loader LL NAIS FP FPG C32T2 CPU direct connection toader LL FPOR C10 CPU direct connection loader LL FPOR C14 CPU direct connection loader LL FPOR C1 CPU direct connection loader LL FPOR C32 CPU direct connection loader LL FPOR T32 CPU direct connection loader LL FPOR F32 CPU direct connection loader LL CPU221 CPU direct connection loader off CPU222 CPU direct connection loader Jo e e CPU224 CPU direct connection loader Jo fof CPU224XP_ pu direct connection load
7. device function makes it possible to monitor the operation element device parameter etc by connecting in a 1 N configuration Up to 32 units GP Editor SmartStudio Drawing data Control program Other input devices Download upload data Other output devices Controls Temperature controller etc 1 1 1 configuration GP LP Series The device function makes it possible to monitor control and the operation element device parameter etc between different devices using two separate communication port GP Editor SmartStudio Control program Other input devices Other output devices Z Download 18888 A Controls PLC type B Controls Temperature controller etc 1 1 N configuration GP LP Series The device function makes it possible to monitor control and the operation element device parameter etc between different devices using two separate communication port In case of RS 422 port 1 N is available only Up to 31 units Control program Other input devices Download upload data Other output devices B Controls Temperature controller etc Bar code printer connection GP LP Series It can read bar code and print a history using printer Download upload data Ya Fad Bar code deader Other input devices Other output
8. efer to GP editer lt Refer to GP LP user manual gt communication manual gt Download display _ data to GP GP connect device lt Refer to GP LP communication manual gt Start monitoring R 2 m Advantages of using GP Complicated environment of operation and control It graphicalizes mechanical control components such as button switch and lamps so that saves cost and space and improves the preservation of devices dia bininin i Control part GP S044 Setting and change of production process It graphicalizes mechanical control components such as button switch and lamps so that saves cost and space and improves the preservation of devices Alarm alert Preservation of history Alarm is occurred PLC GP S044 Convenient setting by user It sets complicated or non displaying controller Thermometer hygrometer temperature controller etc 1 Temperature Humidity without display device rT eee eee aif Display temperature 2 Temperature controller humidity RS485 t Easy to set and adjust parameter Effective data control It prints alarm history of controller using printer It reads the data from barcode reader and save it in PLC 1 PLC Printer PLC GP S044 2 Barcode reader PLC Printer GP S044 Communication between heterogeneous controllers eeeaeveebeeee Thermometer hygrometer GP S044 Autonics General Features
9. er Jo e e CPU224XPsi ru direct connection loader Jo kk CPU226 CPU direct connection loader Jo e e i RD Autonics General Features m Connectable device with GP LP GP LP GP LP cPus12 CPU direct connection ader o CPU312C CPU direct connection loader o fo fo CPU313C_ CPU direct connection loader o fo fe CPU313C 2 CPU direct connection loader o fo Pp CPU314 CPU direct connection loader o fo p CPU314C 2 CPU direct connection loader o fo fe CPU315 2 CPU direct connection loader o fo p CPU317 2 CPU direct connection loader o fo fe CPU319 3 CPU direct connection loader ee O O O l MicroLogicx 1000 CPU direct connection loader Allen Bradley MicroLogicx 1200 MicroLogicx 1500 CPU direct connection loader OMRON SYSMAC C CPU direct connection loader CPU direct connection loader Modbus OMRON Temperature controller Private communication o de Je MT Series Modbus Le le Je Modbus TYPE A e e Je MP Series Private communication 1 Le Modbus ff Je THD Series THO Seres VEE A off AUTONICS Private communication Modb mee K WEEN Modb Modb orses ETEEN DS DA Series Modbus TYPE A ARM Series Modbus TYPE A LP S044 LP S070 SES Modbus DPU Series Modbus TYPEA KONICS R s odbus KRN50 ben V Ze A Modbus DELTA DTB Seri peca Ems Modbus TYPE A Modbus DANFOSS FC Series panross res Modbus TYPE A UNIVERSAL UNIVERSAL Modbus Slave MODBUS MASTER MODBUS MASTER Modbus Master
10. isk space GA 1024x768 or higher resolution display RS 232 serial port 9 pin USB port Autonics General Features m Manual GP LP common manual e GP Editor user manual This section describes how to make screen data and use HMI function with GP Editor e Communication manual For more information of serial connection with external devices such as PLC refer to manual before connecting e GP S044 S057 GP S070 user manual The manual describes installation and system organization and menus LP manual e SmartStudio manual This section describes how to install and use SmartStudio e Programming manual The manual has command and instruction e LP S044 LP S070 user manual The manual describes installation and system organization and menus e LP Series instruction manual The manual has LP installation system configuration and instruction m Precaution for using e Do not press touch panel with hard and sharp object e Please store the device in the recommended temperature range or LCD panel can be damaged e Please check pin number shown in Communication manual when connect communication port e Do not block the ventilating opening of this product e Do not use or store it in a place with direct ray of light or dust e Do not use or store it in a place with shock or vibration e The ground wire of GP LP should be grounded separately The ground resistance should be max 100Q please use the wire of min 1 25mm
11. tion Tacho 2 PC SE 3 Software GP Editor Software for drawing LP screen SmartStudio Software for logic program 4 Manual GP Editor user manual GP LP Communication manual SmartStudio user manual SmartStudio programming manual LP S044 LP S070 user manual LP series command manual 5 Communication cable Communication cable for PC connection Communication cable for controller connection 6 Access device PLC or controller built in communication ports Display Debugging or editing program unit O Sensor controller Control or start monitoring P Switching mode power supply X Refer to the manual for details on website www autonics com resources T Production stoppage models amp replacement U Other General Features m System configurations Stand alone LP Series Stand alone system in LP series controls a variety of O without adding other devices and monitors and control operation element through direct touch of screen device parameter etc Logic program Download upload data Other input Other output devices devices 1 1 configuration LP GP Series The device function makes it possible to monitor the operation data Device parameter etc Download upload data Other input devices Other output devices pip er Bd SS type 1 N configuration LP GP Series The
Download Pdf Manuals
Related Search