Home

Installation & Operating Manual

image

Contents

1. ADJUSTMENT The pilot flow is factory set to maximum The pilot flame should envelope 3 8 to 1 2 of the thermocouple See the illustration above The adjustment screw can be reached through the MAN knob See top illustration above 1 Turn the Man knob to the ON position 2 It is now possible to pierce through a film on the cover with a screwdriver to reach the adjustment screw beneath 3 Turn the adjustment screw clockwise to decrease or counterclockwise to increase the pilot flame 26 REMOTE CONTROL HANDSET OPERATION AND PROGRAMMING Setting C 24 hour or F 12 hour clock Display and timer Thermostat handsets 1 Press OFF and V down arrow until display changes from farenheit 12 hour clock to Celsius 24 hour clock and vice versa Setting the Time Display and Timer Thermostat handsets 1 The display will flash after either a Installing the battery or b Simultaneously pressing the A up arrow and Y down arrow 2 Press A up arrow to set the hour and the V down arrow to set the minutes 3 Press OFF to return to manual mode or simply wait and it will automatically return to manual mode Automatic Pilot Mode With Thermostat Remote If there is no transmission from the handset to the receiver within a 6 hour period the appliance will go to standby pilot mode Flame Height Adjustment In MAN mode Press A up arrow to increase the flame height Press Y down arrow to decrease
2. Also locate the ashlip and ashlip mounting hardware and set aside in a safe location It will be installed later First remove the cast iron stove top This is accomplished by simply lifting up on the top as it is a gravity fit The top is heavy and extra care should be taken when handling it especially if the stove is enameled Set the top aside on a padded surface A carpeted floor is a good choice Remove the top cooking grill and the cooking burner cover plate and set aside for now They are packed in bubble wrap or foam packing and are located on the now exposed top of the stove s firebox Remove the stove front by lifting it straight up to disengage the tabs that secure it to the sides Once it is disengaged you can move the front away from the stove body Note The front doors may have a tendency to swing open while you are handling the front Placing a small piece of masking tape around the two doors where they meet at the center will keep the doors from moving Set the front aside with the back side down taking extra care if it is enameled With these parts removed and set aside lift the stove up and off the pallet and set it near to its installation position Like any cast iron stove it is best to pick the stove up while adjusting its position rather than dragging it on its legs This reduces the chances of damaging a leg or chipping enamel or of damaging the hearth surface This is the best time to install the optional blower kit if bei
3. Example 3 Fuel Natural Gas Vertical Rise 22 feet Horizontal Run 0 feet Elbows 0 none Equivalent Horizontal Run 0 feet Air Restrictor Setting E72 Exhaust Restrictor Setting 7 Inlet Air Example 4 Fuel Propane LP j Vertical Rise 12 feet i Exhaust Horizontal Run 4 feet E Elbows 1 one in Equivalent Horizontal Run 4 feet Air Restrictor Setting E72 Exhaust Restrictor Setting 2 ny Inlet Air Natural Gas Venting 1994 uy uns IejuozuioH Lo 034 1 1 1 18380 CA Le Vie gro D EIE E 22 8 8 2 2 3 2 Vertical Rise In Feet 10 Propane LP Gas Venting QE 9 VENTING ALLOWED VENTING NOT ALLOWED Horizontal Run In Feet wa mn nib RCE an Vertical Rise In Feet 11 PLEASE NOTE If your specific venting configuration falls in a box in the venting charts on pages 10 amp 11 that is above the dotted line you must use one of the approved direct vent venting systems that utilizes a stainless steel inner liner The dotted line corresponds to a total vent length of 30 feet including vertical rise and horizontal run This requirement is part of the ANSI standards and is based on testing conducted to determine where the exhaust gas temperature drops to the point where condensation might occur in the ve
4. PRICE INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entreposer ni utilizer d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucan interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivezles instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindie L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz Cet appareil peut tre install dans une maison Attention Au moment de l entretien des pr fabriqu e mobile d j install e demeure commandes tiquetez tous les fils avant de les si kes r glements locaux le permettent d brancher Des erreurs de la c blage peuvent entrainer un fonctionnement inadequate et Cet appareil doit tre uniquement avec las type dangereux de gaz indiqu sur la plaque signal tique Ce
5. and observe the flames Repeat the process until flame tips shorten and become lighter in color No more than one full increment of adjustment should be used If no change in the flame appearance is noted after that consult with a Harman Stove Company representative P INLET AIR HESTRICTOR GIIIDE PLATE If after 20 30 minutes at high fire the flames are short or blue the fire is probably getting too much air You should first reduce the primary burner air by loosening the adjuster screw locknut and turning the adjuster screw in one turn See the illustration on page 21 for the location of the primary air adjuster screw Wait a few minutes and observe the flames again Make another one turn adjustment If the flame appearance has not changed after two turns of the adjuster screw it is likely that there is another cause for the short or blue flames Note Do not turn the primary air adjustment screw in more than two turns The flames should not have dark or sooty tips and should not be extending so high as to touch the baffle If adjusting the primary burner air doesn t improve the flame appearance a small adjustment of the inlet air restrictor can be made This can be done with the stove operating but care must be taken not to touch hot surfaces while making the adjustment Loosen the inlet air restrictor guide plate locking screw and move the setting up by increment For example move from a setting of E to a setting of E 74 Tighten the loc
6. are the closest to your feet feet b a ae E to C 4 10 A 0 your vent rise is eet use the 15 D 4 2 15 54 2 setings or 15 Tet if ihe vent 15 ove 6 16 o et rise is 18 feet use the settings for e Se 20 D 614 20 feet Note The vent rises are 2 ul 2552 pr j 6 1 4 30 C12 actual vent rise For example if ir C 1 2 measured from the centerline of NE NE 1 51 2 the rear vent starter 4 12 IM Vent Terminal e Ar supply inet pd where terminal is not permitted Vent Termination Clearances Canadian Installations US Installations A Clearance above grade veranda porch 12 inches 37 12 inches 30 cm ar halean B Clearance to window or door that may be 12 inches 3 cm 3 inches 23 cm opened Clearance to permanently closed window aee Footnotes 3 Eb aee Footnote 5 D Verbcal clearance to a ventilated soft lo See Footnotes 5 amp 5 See Footnote 5 gaad above the terminal within horizont al distance of Z teet 1 cem from the Lese of the terminal Clearance l inside comer See Footnote 5 G Clearance outside comer See Fontnotes 586 SeeFontnate tended above meter regulator a55embl 4 5 m above the regulator meter assembl l Clearance senice regulator vent outlet 3 feet 91 em let t building or the combustion eir inlet any other appliance k Clearance to a mechanical air supply
7. cooking burner off turn the knob to the OFF full clockwise 7 position FIG 4 24 Lighting amp Operation COOKING BURNER OPERATION The cooking burner on your FireLuxe functions like a cooking burner on any conventional kitchen range A battery powered flame sensing automatic ignition system lights the burner when you depress the control knob and rotate counterclockwise to the High H position You will hear a clicking sound and can observe the spark arcing from the igniter electrode to the burner body Once the burner is lit the flame sensor will shut off the spark If for any reason the sensor does not detect a flame the igniter will automatically resume sparking until the flame is detected again will occur when open burning with no cook pot or pan The flames should be blue and evenly distributed around the perimeter of the burner See the illustration below Adjust the flame for the desired heat level by rotating the knob To turn the burner off rotate the knob clockwise to the OFF position See fig 4 on page 24 Refer to the lighting instructions on page 24 and the lighting and operating instructions on the permanent metal label attached by cable to the rear of the stove WARNING THE COOKING BURNER IS FOR ATTENDED USE ONLY DO NOT LEAVE ON UNATTENDED FOR ANY REASON WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGN
8. hard wired carbon monoxide detector with an alarm and battery back up must be installed on the floor level of the dwelling building or structure where the appliance is to be installed Additionally a hard wired or battery operated carbon monoxide detector with an alarm must be installed on each additional level of the dwelling building or structure served by the appliance It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors In the event that the horizontally vented appliance is installed in a crawl space or attic the hardwired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level In the event that this requirement cannot be met at the time of completion of the installation of the appliance the owner shall have a period of thirty 30 days to comply with the requirement However during said thirty 30 day period a battery operated carbon monoxide detector with alarm must be installed Each carbon monoxide detector as required in accordance with the above provisions must comply with NFPA 720 and be ANSI UL 2034 and IAS certified In addition when the stove is horizontally vented and the vent termination is less than seven 7 feet above finished grade a metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height o
9. i RESET E Receiver Reset Button Dip Switch in Remote Handset Battery Compartment 2 Press and hold the receiver s reset button until you hear two 2 acoustic signals After the second longer signal release the reset button and within the next twenty 20 seconds press the V down arrow on the remote handset til you hear and additional long signal that confirms the new code is set above Maintenance qualified service agency should conduct an annual inspection and maintenance of your FireLuxe including the overall installation and venting to keep it running safely The following procedures should be performed only by a qualified service person The gas supply should be turned off and the stove should be completely cool whenever a maintenance procedure is performed All parts of the appliance that are removed for servicing must be replaced prior to operation WARNING Do not operate the appliance with the glass front removed cracked or broken Replacement of the glass should be done by a qualified service person WARNING Use only replacement glass part number 3 40 21001500 and glass gasket part number 3 44 00539 Do not use substitute materials Do not strike or slam the glass front REPLACING THE GLASS The glass mounting system consists of the glass panel special glass gasket and the metal glass frame Should the glass need to be replaced you must use the glass replacement parts that can be obtained from your author
10. leaving the factory Harman Stove Company and its agents assume no liability for resultant damages of any kind arising from the use of its products In addition the manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related to the operation proper or improper of the equipment THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user s manual THESE WARRANTIES WILL NOT APPLY if abuse accident improper installation negligence or use beyond rated capacity causes damage HOW TO MAKE A CLAIM Any claim under this warranty should be made to the dealer from whom this appliance was purchased Then contact is made with manufacturer giving the model and serial numbers the date of purchase your dealer s name and address plus a simple explanation of the nature of the defect Extra costs such as mileage and overtime are not covered Nuisance calls are not covered by these warranties THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS REPAIR AND OR REPLACEMENT AT HARMAN STOVE COMPANY S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH WARRANTY EXCLUSIONS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited
11. log next There is a recessed area on the top of the burner that corresponds to the shape of the base of the log Simply place the log in the recess The following illustration shows the proper positions for the two rear logs LEFT REAR LOG Em RIGHT REAR LOG Assembly Place the left front log next Again there is a recess on the burner top that corresponds to the shape of the flat base of the log Place the left end of the log in the recess and rest the right end on the left rear log using the illustration below as a guide Place the right front log last Again place the flat base of the log in the corresponding recess in the burner top per the illustration below There are three loose ember pieces Each ember piece has a specific location on the burner Refer to the illustration below to get the proper placement and orientation for each ember piece If you look carefully you will see that each ember has features that will help you in placement relative to the burner surface and the logs Assembly When correctly placed the logs and embers will look like the illustration below After the logs and embers have been placed the next step is to replace the glass panel and frame Carefully pick up the glass and glass frame assembly by grasping the sides of the frame and using your thumbs and fingers to hold the glass in place within the gasket and frame With the glass frame and glass at a slight angle leaving room for your fi
12. proper positions Install and tighten the LATE gt four screws Finally install the vent starter T section in the rear vent position Again OUTER make sure that the inner and outer gaskets are Se ST GASKET INNER CASKETS in their proper positions and install and tighten the four screws At this time you will also want to install the optional cast iron plate that fills in the top vent cutout on the stove top With the bottom of the top facing up place the filler plate in the cutout with the filler plate edge molding aligned with the edge molding on the top Using the bracket and three fasteners included with the filler plate kit secure the filler plate to the top See the illustration included with the optional filler plate kit for more information i STARTER SECTION It is now time to install the ashlip on the stove front and to install the stove E Ron stove top The ashlip is secured to the front using two brackets and four 1 4 20 hex head bolts With the front facing down on a padded surface align the mounting bosses on the ashlip with the mounting bosses on the front Install the two L shaped brackets with the slotted end on the ashlip Tighten the bolts to the front but leave the bolts to the ashlip finger tight Carefully turn the front over Adjust the ashlip so that it is tight against the lower molding on the front Tighten the ashlip bolts Take care wit
13. the flame height or set the appliance at pilot flame For fine adjustments tap the up down arrows Lighting amp Operation me TEMP MODE Daytime Temperature Mode appliance must be in standby mode pilot ignited The room temperature is measured and compared to the set temperature The flame height is automatically adjusted to achieve the daytime set temperature setting J TEMPMODE Nighttimesetbacktemperature mode appliance must be in standby mode pilot ignited The room temperature is measured and compared to the setback temperature The flame height is automatically adjusted to achieve the night time setback temperature setting nues TIMER MODE appliance must be in the standby mode pilot ignited The timer setting allows you to set two 2 burner ON times and two 2 burner OFF times for every 24 hours NOTE The display shows the set temperature every 30 seconds Changing the Mode of Operation Briefly pressing the SET button changes the mode of operation in the following order man nes and back to NOTE mode can also be reached by pressing either the A up arrow or the V down arrow MAN Mode Manual Flame Height Adjustment 1 Press up arrow to turn on the main burner 2 Press A up arrow to increase the flameheight 3 Press W down arrow to decrease the flame height or to go to pilot standby NOTE While pressing either button a sy
14. the valve See Fig 1 Once the pilot flame is observed continue to hold in the manual pilot valve operator for about one 1 minute Release the manual pilot valve operator If the pilot does not stay lit repeat steps 2 through 5 Note If the pilot does not stay lit after several tries turn the main valve knob to OFF and proceed to step 7 Turn the MAN knob to the ON full counterclockwise position If the appliance will not operate follow the instructions TO TURN OFF GAS TO MAIN BURNER and call your service technician or gas supplier TO TURN OFF GAS TO MAIN BURNER 1 Press the OFF button on the remote if available Turn the main valve knob to the OFF full clockwise 7 position LIGHTING INSTRUCTIONS COOKING BURNER 1 Stop Read the safety information shown on the top of page 23 Locate the cooking burner gas control knob at the top right rear of the appliance Refer to Fig 4 below for more information With the valve the OFF position push down on the knob and turn counterclockwise to the H High position The cooking burner has a built in electronic ignition system and the burner will ignite automatically If the burner does not light within five 5 seconds turn the knob to the OFF full clockwise 4 amp position and call your service technician or gas supplier Adjust the burner for the desired cooking heat level TO TURN OFF GAS TO COOKING BURNER To turn the
15. to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners combustion packages door packing tile ceramic log sets paint batteries or battery backups and related duct work are not covered Also excluded from this warranty are consumable or normal wear items including but not limited to flame guides grates coal bars afterburner hoods fire brick gaskets Additional exclusions for corn stoves are burn pot housing weldment burn pot grate weldment pellet or corn burnpot front plate pellet or corn burnpot front plate lock grain caps corn auger extension ceramic insert and ceramic insert plate Additional or unusual utility bills incurred due to any malfunction or defect in equipment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not covered Maintenance needed to keep the stove in good operating condition is not covered This includes but is not limited to cleaning adjustment of customer controls and customer education Labor materials expenses and or equipment needed to comply with law and or regulations set forth by any governmental agencies are not covered This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state In the event of change in ownership the remaining portion ofthis warranty may be transferred to the new owner by sending the new owner information and a transfer fee
16. 2 psi 3 5kPa The FireLuxe must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psi 3 5kPa After the gas supply has been connected apply a soapy water solution to all the fittings to check for gas leaks Never use a flame to test for leaks 20 Assembly PRIMARY AIR ADJUSTER 1 1 T Your FireLuxe gas stove was shipped from the factory equipped for the fuel type indicated on the rating 11 plate that is attached to the rear of the stove and the primary burner air adjuster was set at the factory at the recommended position for that fuel If you will be using the alternate fuel please see the instructions included with the optional fuel conversion kit This includes instructions for the proper setting for the primary air adjuster The recommended setting for propane is the fully open position This corresponds to the adjuster screw fully backed out The recommended setting for natural gas is the fully closed position This corresponds to the adjuster screw fully screwed in PRIMARY AIR ADJUSTER Making small adjustments to the primary air setting will SCREW let you adjust the way the flames look for your particular installation See the reference to primary air adjustment in the section below that discusses the air inlet and exhaust outlet restrictors AIR INLET AND EXHAUST OUTLET
17. ITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE WARNING BASED ON SAFETY CONSIDERATIONS THE COOKING BURNER FLAME SHOULD BE ADJUSTED SO IT DOES NOT EXTEND BEYOND THE EDGE OF THE COOKING UTENSIL WARNING BASED ON SAFETY CONSIDERATIONS DO NOT USE THE COOKING BURNER FOR SPACE HEATING UNDER ANY CIRCUMSTANCES ERMO CODITPLE FLAME BURNER IGNITION FLAME CORRECT COOKING BURNER F LA CURRECI PILOT FLAMES PILOT AND MAIN BURNER OPERATION Follow the lighting instructions on pages 23 24 When the pilot is lit and operating properly it should look like the illustration above One flame will be directed at the pilot thermocouple and the other will be emanating toward the burner If the pilot flames do not resemble the illustration above see the instructions on page 26 for pilot flame adjustment After the main burner ignites and has been in operation for a few minutes the flames should look like the illustration on the top of page 26 Flame height will vary depending on the firing rate but flames should be burning in all of the indicated areas 25 Lighting amp Operation CORRECT MAIN BURNER FLAMES Pilot Gas adjustment Screw turn with screwdriver MAN knob PILOT FLAP ADJUSTMENT Main Valve Knob CORRECT PILOT FLAMES THERMOCOUPLE FLAME PILOT FLAME
18. Installation amp Operating Manual The Harman FireLuxe Direct Vent Gas Stove With Top Cooking Burner System Wa seges ul F ge prO oh Di alle a Gand wo m in bu LS Mabon Free i Hol CILE oscuras WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Report 135 8 15 5 This appliance may be installed an aftermarket permanently located manufactured home USA only or in a mobile home where not prohibited by local codes This appliance is for use only with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified conversion kit is used Ce manual est disponsible en Francais sur demande HARMAN BUILT TO A STANDARD NOT
19. N BURNER Natural Gas Propane LP Input Rating Btu hr 36000 36000 Min Input Btu hr 23000 23000 Orifice DMS 34 50 COOKING BURNER Input Rating Btu hr 12000 12000 Min Input Btu hr 3500 3500 Orifice DMS 52 58 GAS SUPPLY Manifold Pressure 4 5 w c 1 1kPa 10 0 w c 2 5kPa Min Supply Pressure 5 0 w c 1 3kPa 11 0 w c 2 8kPa Max Supply Pressure 10 0 w c 2 5kPa 13 0 w c 3 3kPa Annual Fuel Utilization Efficiency AFUE 72 7 74 996 Steady State Efficiency 73 496 75 696 It is recommended that the pilot flame be turned off if the appliance will not be in use for an extended pe riod of time This appliance is equipped for use with the fuel type indicated on the rating plate Fuel conversion kits that include the necessary parts and instructions are available from your installer dealer or Harman Stove Co This appliance has been certified by OMNI Test Laboratories Inc to ANSI Z21 88 2005 CSA 2 33 2005 Vented Gas Fireplace Heaters and CAN1 2 17 M91 Gas Fired Appliances for Use At High Altitudes The FireLuxe is approved for installation at elevations up to 2000 feet in the U S and 1370 meters 4500 feet in Canada without change If your installation is at an elevation greater than these consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations 2077 52 cm Installation Several issues must be addressed when selecting a sui
20. RESTRICTORS The FireLuxe is equipped with externally adjustable restrictors for both the inlet air and the exhaust outlet This makes it possible to fine tune the direct vent system for the specific conditions of your installation The recommended settings are keyed to the specific details of your venting configuration To access the restrictor adjustment guide plates you must first remove the access plate Looking at the stove from the front this plate is located on the upper left rear of the stove If you have the optional blower the access plate also contains the blower speed control Remove the single fastener that secures the access plate Set the plate aside or if the blower is installed let the plate hang on the wiring Next remove the heat shield This is held in place with a single fastener located at the lower front corner of the shield With the fastener removed tilt the heat shield as needed and remove Refer to the illustrations below iQ ES 2 28 xO OD T RER Kad es FAS TENER HEAT SHIELD FASTENER us WM ACCESS COVER FE DE weg cows Rt o 21 Assembly You will now see the two guide plates The guide plates have a pointer that corresponds to a letter scale for the air adjustment and number scale for the exhaust adjustment These are the letters and numbers that are referenced in the venting charts on pages 10 and 11 and shown in detail in the example
21. after WY on off Servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut the grounding prong from this plug Check the blower for any build up of dust lint or pet hair during the annual service appointment 29 HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED HARMAN WARRANTY Residential GOLD 1 YEAR LIMITED WARRANTY Commercial MOI Harman Stove Company warrants its products to be free from defects in material or workmanship in normal use and service for a period of 6 years from the date of sales invoice and for mechanical and electrical failures in normal use and service for a period of 3 years from the date of sales invoice If defective in material or workmanship during the warranty period Harman Stove Company will at its option repair or replace the product as described below The warranty above constitutes the entire warranty with respect to Harman Stove Company products HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE No employee agent dealer or other person is authorized to give any warranty on behalf of Harman Stove Company This warranty does not apply if the product has been altered in any way after
22. d Recreational Vehicles and Mobile Housing CSA Z240 4 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5kPa The installation must provide for adequate ventilation air to the appliance This gas appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 f When the appliance is installed directly on carpeting or non ceramic tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance A commercially available hearth pad meets this requirement The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids The flow of combustion and ventilation air must not be obstructed Do not use this appliance if any part has been under water Immediately call a qualifed service
23. f eight 8 feet above grade directly in line with the exhaust vent terminal The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH INCLUDE PARTS LISTS AND OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT THE COMPLETION OF THE INSTALLATION ATTENTION INSTALLERS Mark below which venting system was used in the installation These instructions must remain with the FireLuxe Installation amp Operation Manual Simpson DuraVent GS _ AmeriVent Direct Security Secure Vent Selkirk DT Excel Direct The FireLuxe Gas Stove has been tested and listed for installation with 4 X 6 5 8 Simpson DuraVent GS AmeriVent Direct Security Secure Vent ICC Excel Direct and Selkirk DT direct venting components The total vent length may not exceed 40 feet including vertical rise and horizontal run The vent lengths are measured from the stove not the floor The minimum vertical rise required is 2 feet The maximum allowed horizontal vent run is 20 feet when the venting includes at least 5 feet of vertical rise The maximum allowed horizontal vent run for vertical rises of less than 5 feet is shown in the venting charts No more than three elbows may be used in any installation The venting charts include the use of one elbow For the second or third elbows that are included in the installati
24. h an enamel stove to prevent chipping Replace the stove front by aligning the outer edges with the stove sides while the front is about 72 to 1 above its final position This is to allow the sheet metal tabs that secure it to the sides to be above the mating cast iron tabs on the sides Carefully push the front in while allowing it to slide down All four tabs two top and two bottom should engage with the sides Once the front has reached the proper position check the vertical alignment by looking at the alignment of the edges of the front to the casting details on the side They should be parallel If they are not simply push or pull on the front until a good visual alignment is obtained Take extra care with this procedure if your stove is enameled Just move in small increments as you line up the tabs and lower the front into place If you take your time you will avoid chipping Remove any masking tape used to secure the doors Next install the brass diffuser ring and top burner cover on the cooking burner This is a small round disk that sits on top of the brass diffuser ring on the top burner If you look at the back side of the diffuser you will see alignment tabs They correspond to alignment locations on the burner The cover is simply centered in the diffuser 18 Assembly Next reinstall the top This is a gravity fit Carefully align the inner edge of the top with the outer edges of the sides and front Lower the to
25. inlet B feet 1 563 m 3 feet 81 cm above if within 10 feet 3 m horizontall divway located on public property balcon Footnotes 1 In accordance wih the CSA P419 1 Natural Gas and Propane Installation Code 2 In accordance with the cument ANSI 7223 1 NFPA 54 National Fuel Gas Code 3 Avent shall not terminate directly above a sidewalk or paved driveway that ks located between two single family dwellings and senes both dwellings 4 Permitted only f veranda porch deck or balcony ts fully open on minimum of two sides below the floor 5 Clearance in accordance with local installation codes and the requirements ofthe gas cupplior b D gagement conforme aux codes dinstallstion locaux et aux exigences du foumisseur de gaz Venting terminals shall not be recessed into a wall or siding 13 Assembly UNPACKING AND PLACING THE FIRELUXE By now you will have removed the shipping carton from the base pallet The FireLuxe is shipped on specially designed shipping supports that keep the weight of the stove off the legs to avoid damaging them during transit Cut the strapping that secures the stove to the pallet The stove must be lifted straight up to disengage it from the shipping brackets The best place to lift is at the base of the stove sides The stove top and front have to be removed in order to unpack and install the logs and top cooking burner parts Removing them now will reduce the weight and make it easier to lift the stove
26. ized Harman dealer When replacing the glass you must use a new glass gasket Use the following procedure and refer to the illustrations on pages 14 and 17 of this manual 1 Turn the stove completely off and allow it to cool completely 2 Remove the Stove Top and Stove Front See instructions on page 14 3 If the glass is broken be sure to wear gloves and eye protection 4 Unlatch the three glass frame latches by pulling forward on the latch finger tabs while lifting up This will allow the glass frame to tip slightly forward The glass is loose in the frame held in place only by friction from the gasket so it is very important to support both the glass and the frame when handling Place your thumbs on the outside of the glass frame and wrap your fingers around the frame and onto the glass Squeeze the frame and glass while moving Carefully lift the glass frame and glass up and off the stove Set the glass and frame aside on a padded surface If the glass is broken do this over spread out newspaper to catch all loose material The outside of the frame should be facing down to give access 5 Carefully remove the old glass and gasket material If the glass is broken wear gloves and eye protection 6 Be sure to remove any broken glass from the burner and logs 7 Install the new glass gasket onto the glass panel following the instructions included with glass panel 8 With the thin section of the glass gasket facing the inside of the glass frame caref
27. king screw and observe the flames Repeat the process until flame tips begin to extend and become more yellow in color Note DO NOT OVER ADJUST THE INLET AIR RESTRICTOR The flames should not have dark or sooty tips and should not be extending so high as to touch the baffle Once all adjustments are made make sure the inlet air and exhaust restrictor guide plate locking screws are tight and replace the heat shield heat shield fastener and the access plate and fastener If an adjustment was made to the primary burner air tighten the locknut on the adjustment screw to lock in the new setting 22 Lighting amp Operation FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life THIS APPLIANCE HAS TWO SEPARATE BURNER AND GAS CONTROL SYSTEMS ONE SYSTEM IS FOR THE MAIN HEATING BURNER AND THE SECOND IS FOR THE TOP COOKING BURNER A BEFORE OPERATING EITHER BURNER SYSTEM smell around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light the appliance Do not touch any electric switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions f you cannot reach your gas supplier call the fi
28. lkaline battery and reinstall the cover 19 Assembly The main heating valve battery pack is located at the center rear of the stove removable valve access panel covers the valve components and simply lifts up and off the stove back The batteries are located in the control module next to the actual valve The battery access cover lifts and slides off to expose the four AA batteries Note the orientation of each battery as you replace the old with new as this is critical to the operation of the control Use only high quality long life alkaline batteries Replace the battery cover and the valve access panel Refer to illustrations below NOTE The control module is secured to the valve bracket with hook and eye strips and can be pulled away from the bracket if necessary to gain better access to the battery cover and compartment Be certain not to dislodge the wiring from the control module and be sure to place the module back it its original position after the batteries and cover are installed GAS CONNECTION The FireLuxe is shipped from the factory with a flexible gas connector that has a 1 2 NPT female connection The gas supply piping should have a separate gas shut off valve and a 1 8 NPT plugged tapping upstream of the valve The FireLuxe and its inlet regulator Main burner valve and cooking burner valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1
29. lly lift the glass frame and glass up PILL FORWARD AND gt 2 and off the stove Set the glass and frame aside on a padded TO UNHOOR LATCH y FROM GLASS FRAME surface The outside of the frame should be facing down so the glass will stay in place 14 Assembly LOGS AND EMBERS Slide the logs and packing out of the firebox and set on the floor Carefully unpack each of the four logs and three loose ember pieces The logs and embers are somewhat fragile and will not survive being dropped from any significant height Remove the protective cover material from the top of the burner Each of the four logs is unique and must be placed in a precise location on top of the burner The burner and log system is designed to facilitate correct placement of the logs Flat recessed areas on the burner top are keyed to each of the four main logs The rear logs also have locating pins with corresponding sockets in the logs The following illustration highlights these features 5 RIGHI REAR LOG RECESSES LEFT REAR LO JG RECESS _ BA 1 LT res 4 1 A m LETT FRONT rm RL e Fih Du N k AS ponai gt Te 9 RIGHT FRONT LOG RECESS F Place the left rear log first There is a recessed area in the burner top as well as a locating pin and a corresponding socket in the log Line up the socket over the pin and place the log in the recess Place the right rear
30. manual to insure proper placement of the logs and embers on the burner AIR FLOW The FireLuxe utilizes a convection air heat exchange system to maximize heat delivered from the stove It is important that air flows freely through the convection air system and out the front and side air grills Do not place objects under the stove that will block the convection air inlet flow or in front of any air grill If the optional convection air blower is installed check the blower during the annual service appointment for any build up of dust lint or pet hair COOKING BURNER SYSTEM As with any conventional range top the FireLuxe cooking burner will require routine cleaning The porcelain enameled drip pan should contain most normal cooking spills To clean simply remove the cooking grate and wipe the drip pan with a moist sponge or paper towel Be sure that the stove is cool before cleaning The cooking grate also has a porcelain enamel finish for easy cleaning We recommend handwashing rather than the dishwasher Spills on the top of the stove should be wiped up immediately to prevent them from baking on OPTIONAL CONVECTION AIR BLOWER SYSTEM Part No 1 00 05895 For additional information please see instructions included with the blower kit FiraLuxe Optional Blower CAUTION Label all wires prior to disconnection Wiring Diagram when servicing Wiring errors can cause improper and Blower Speed Control dangerous operation Verify proper operation
31. mbol indicating transmission appears on the display The receiver confirms transmission with an acoustic signal or beep Setting The Temperature 1 Select either the mode or the by briefly pressing ir T button 2 Hold the SET button until the TEMP display flashes 3 Set the desired temperature with A or V up or down arrow button s NOTE 4 5 C 40 F is the min temperature setting 4 Press OFF or simply wait and the display will go to the temperature control mode NOTE To turn off the night setback temperature control decrease the night time temperature until appears on the display mode Setting The Timer 1 Select timer mode by briefly pressing the SET button 2 Press and hold SET until TIMER is displayed on the lower right hand side 3 Press and hold SET until the P1 3 sun symbol and the time display flashes Set the hour by pressing the A up arrow and set the minutes by pressing the down 4 Briefly press SET for the next burner cycle time EXAMPLE P1 J moon symbol continue through P2 5 symbol and P2 J moonsymbol 5 Once all four 4 times are set press OFF or simply wait to complete programming HANDSET fr UP DoW Radio Frequency Inteference A frequency code is preset for the valve receiver and remote handset but can be changed if you are experiencing interference from other devices To change the code 1 Change DIP switch position pamm
32. ng used See the instructions included with the blower kit The legs have leveling screws that will allow you to compensate for irregularities on the surface under the stove Using as little adjustment as possible for each leveling screw adjust them as needed to get the stove as level as possible both side to side and front to back This is important since the FireLuxe includes a top cooking burner and having the stove level will reduce the likelihood of spillage while cooking The FireLuxe is shipped set up for the fuel type indicated on the rating plate attached to the rear of the stove Note If you need to switch fuels please see the instructions included with the appropriate fuel conversion kit The logs are shipped in protective material inside the firebox and do need to be unpacked and installed on the burner With the stove top and front removed and safely set aside during the unpacking process unlatch each of the three glass frame latches by pulling forward on the latch finger tabs while lifting up See the adjacent illustration This will allow the glass frame to tip slightly forward The glass is loose in the frame held in place only by friction from the gasket so it is very important to support both the glass and the frame when handling Place your thumbs on the outside of the glass frame and wrap your fingers around the frame and onto the glass Squeeze the frame and glass A UNLATCHING DETALL while moving Carefu
33. ngers between the frame and the firebox insert the bottom edge of the frame into the frame retainer located on the bottom front of the firebox Take care to center the frame from left to right Once the bottom edge is in place move your CH Jin fingers out of the way and press the top of the frame LATCHING DETAIL k against the firebox while pushing down to be sure the PULL FORWARD AND eR frame is fully engaged in the frame retainer Hold the DOWN TO HOGE LATCH s frame in place with one hand and engage the three OVER GLASS FRAME TM glass frame latches by pulling out and down while hooking them over the frame Top or Rear Vent The FireLuxe has provisions for either top or rear venting but is shipped from the factory set up for top venting The rear position is sealed with a special cover plate If your installation requires rear venting you will need to reverse the positions of the starter section and the cover plate Remove the four screws that secure the vent starter section flange to the stove and remove the starter There are two ceramic fiber gaskets that seal the starter to the stove These gaskets are very important Take care in handling these gaskets as they are somewhat fragile and will tear Remove the vent cover plate from the rear of the stove following the same procedure as the starter Install the cover plate on the top vent opening 17 Assembly Be sure that the inner and outer gaskets are in their
34. nt pipe The standards require the use of corrosion resistant liner materials if that specific total vent length is exceeded VENTING INTO AN EXISTING MASONRY OR CLASS A CHIMNEY The FireLuxe has been tested and found to be in compliance when using an existing chimney as the air conduit for the direct venting system However before proceeding check with the local authority having jurisdiction to see if this type of installation is allowed in your area This type of installation is used when replacing an existing wood burning stove with a FireLuxe direct vent gas stove Check with the installer or venting manufacturer to see if they have the needed components or kits for this type of installation Also check the vent manufacturer s installation instructions for the specific details and requirements for this type of installation The chimney must be in good condition with no cracks or leaks for this type of installation including the cleanout door and the venting components must be completely sealed where they meet the existing chimney The chimney must not be connected to any other appliances Note If your chimney has been problematic when using your woodstove low draft backdrafts etc performance problems may also occur when the chimney is used with a gas appliance VENTING INTO AN EXISTING FIREPLACE The FireLuxe may be vented through an existing fireplace chimney The fireplace opening must be at least 28 high All clearances to adjacent comb
35. of 25 00 US to the Harman Stove Company PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DEVICES THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES NOT HARMAN STOVE COMPANY OR THEIR WARRANTY ADMINISTRATOR FURTHERMORE THESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFACTURER REMEDIES The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or anything done in connection therewith whether in Contract in tort under any warranty or otherwise shall not except as herein expressly provided exceed the price of the equipment or part of which such liability is based CLARIFY The above represents the complete warranty which is given in connection with stoves manufactured by Harman Stove Company No other commitments verbal or otherwise shall apply except by a written addendum to this warranty For replacement parts and customer service contact your Harman Stove Dealer Manufactured by HARMAN BUILT TO A STANDARD NOT PRICE 352 MOUNTAIN HOUSE ROAD HALIFAX PA 17032 R5 ver 06 23 12
36. on add 4 feet to the actual horizontal run for each elbow to determine the equivalent horizontal run for the installation The venting charts allow a simple way to determine the recommended initial settings for both the air inlet and exhaust restrictors These settings have been determined by extensive testing and will be a good starting point while setting up the stove Small adjustments from these settings may be needed to account for specific installation variables Please see the instructions on pages 21 22 for how to adjust the restrictors The letters A E designate the position of the air inlet restrictor When is added to the letter designation this indicates that the position is halfway between adjacent letters The numbers 0 8 indicate the position of the exhaust restrictor When 7s 74 75 is added to the number designation this indicates that the position is fractionally between adjacent numbers For example 5 is one fourth the way between 5 and 6 To use the charts determine the horizontal run length and vertical rise length in feet for your installation If more than one elbow is used add 4 feet to the actual horizontal run length for each additional elbow to get the equivalent horizontal run for the chart Note Remember that a maximum of three elbows is allowed Select the venting chart for the fuel type Natural Gas or Propane LP Gas and find the box on the chart that corresponds to the vertical rise and act
37. or turns automatically to maximum Flame height Note If the pilot does not stay lit after several tries turn the main valve knob to OFF full clockwise position Proceed to step 8 7 Set the thermostat to the desired setting or use the remote control to adjust flame In standby mode press A up arrow to increase the flame height press V down arrow to decrease flame height or to set appliance at pilot flame See page 26 for remote handset programming instructions 8 If the appliance will not operate follow instructions TO TURN OFF GAS TO MAIN BURNER on the next page and call your service technician or gas supplier 23 Lighting amp Operation MANUAL IGNITION 1 2 STOP Read the safety information on the top of page 23 Locate the valve on the back of the stove Turn the main valve knob to the OFF full clockwise 4 Ts position Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow A in the safety information on page 23 If you don t smell gas proceed to Step 4 Visually locate the pilot at the center rear of the firebox Refer to Fig 3 below With the MAN knob in MAN position a manual pilot valve operator is accessible Refer to Fig 1 Fully push down the manual pilot valve operator using a small screwdriver or pen tip and hold in to start pilot gas flow Immediately light the pilot by rapidly depressing the piezo igniter button on
38. orner Ceiling Mantel Installation NOTE If you will be installing the optional warming shelves make sure to plan for the additional width that they occupy For the details see the information included with the warming shelf kit The gas stove is shipped with a flexible connector that has a 1 2 NPT female connection The gas supply piping should have a separate gas shutoff valve and a 1 8 NPT plugged tapping upstream of the valve The stove and its main control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The stove must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psi 3 5 kPa After the gas supply has been connected apply a soapy water solution to all the fittings to check for gas leaks Never use a flame to test for leaks REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts If this appliance is installed in a dwelling building or structure used in whole or in part for residential purposes and the installation includes a horizontal vent termination that is less than seven 7 feet above the finished grade in the area of the venting including but not limited to decks and porches a
39. p down into place Check to see if it is level and push down as needed to get the proper alignment relative to the aesthetic details on the front and sides Finally install the top cooking grate This simply sits over the burner A raised border on the stove top defines the cooking grate position BATTERY INSTALLATION OR REPLACEMENT The batteries used to power the burner control systems on the FireLuxe should last a full season or more with normal use Battery life for the main burner control system will be reduced if you are manually modulating the flame up and down on a frequent basis There are three battery locations The electronic ignition module for the cooking burner is located behind an access panel located on the right rear of the stove when looking from the stove front A single fastener secures the panel Simply remove fastener and the panel to access the single 9 volt battery Unsnap the old battery from the module and replace with a fresh one Use a high quality long life alkaline battery Replace the access panel and fastener Refer to the illustrations below xam roo r1 F r ke xri ue ACCESS COVER Pal celis eae o SYBATTERY The remote control handset is powered by a 9 volt battery There is a low battery indicator on the handset display panel To replace the battery remove the access cover from the rear of the handset and unsnap the old battery Replace with a high quality long life a
40. re department B Use only your hand to operate the gas controls Never use tools If a knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion C Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water LIGHTING INSTRUCTIONS Main Burner AUTOMATIC IGNITION 1 STOP Read the safety information above 2 This appliance is equipped with an igntion device that automatically lights the pilot When using the remote handset do not try to manually light the pilot 3 Push the OFF button on the remote handset to insure the appliance is off 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow A in the safety information above If you do not smell gas proceed to step 5 5 Turn the MAN knob to the ON full counterclockwise position Refer to Fig 1 on page 24 6 Simultaneously press and hold the star and A up arrow on the remote control unit see Fig 2 until a short acoustic signal confirms the start sequence has begun release the buttons Continuing sig nals confirm the ignition sequence is ili Once pilot ignition is confirmed there is gas flow to the burner WARNING When pilot ignition is confirmed the valve mot
41. s shown on pages 8 and 9 To change the setting loosen the guide plate locking screws Next rotate each guide plate to the recommended setting for your installation shown in the appropriate venting chart for natural gas or for propane LP gas Once the settings are correct tighten the locking screws EXHAUST RESTRICTOR GUIDE PLATE LOCKING SCREWS It is a good idea to test fire the stove before you replace the heat shield and access cover Follow the lighting and operation instructions starting on page 23 Allow the stove to burn for at least 20 30 minutes at high fire while observing the flame Although the flames will become more luminescent as the stove heats up the tips of the flames should not be dark or sooty or extending so high as to touch the baffle If they are some additional adjustment is needed First check the position of the primary burner air adjuster For propane the primary air adjuster should be in the fully open position If it is not loosen the adjuster screw locknut back out the adjuster screw If no difference in the flame appearance is noted a small adjustment of the exhaust restrictor should be tried next This can be done with the stove operating but care must be taken not to touch hot surfaces while making the adjustment Loosen the exhaust guide plate locking screw and move the setting down by increment For example move from a setting of 6 1 2 to a setting of 6 74 Tighten the locking screw
42. t appareil ne peut tre converti d autres gaz S assurer que l appareil fonctionne ad quatement sauf si une trousse de conversion est utilis e une fois l entretien termin Ne pas utiliser cet appareils il a t plong meme partiellement dans l eau Appeler un AVERTISSEMENT Ne pas utiliser l appareil technician qualifi pour inspecter l appareail et si le panneau frontal en verre n est pas en place remplacer toute partie du systeme de commande est craqu ou bris Confiez le remplacement du et toute commande qui a t plong e dans eau panneau un technician agree INSTALLATEUR Laissez cette notice avec l appareil COMSOMMATEUR Conservez cette notice pour consultation ult rieur Table Of Contents IMPORTANT SAFETY INFORMATION SPECIFICATIONS INSTALLATION MASSACHUSETTS REQUIREMENTS VENTING ASSEMBLY LIGHTING AND OPERATION REMOTE CONTROL HANDSET OPERATION amp PROGRAMMING MAINTENANCE WARRANTY Important Safety Information The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 or the Canadian Installation Code CAN CGA B149 A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the Standard for Manufactured Home Installations ANSI BCSBCS 225 1 or Standard for Gas Equippe
43. table location for your FireLuxe The minimum clearances to combustible construction are listed below In addition access to the gas supply and electrical supply must be considered The location of the stove will also affect the venting requirements and you must be certain the location will allow compliance with the venting requirements shown on pages 8 13 You must also insure that your installation provides adequate accessibility clearance for servicing and proper operation When the appliance is installed directly on carpeting or tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that the control compartments burners and circulating air passageways of the appliance be kept clean MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION Stove to Left Side Wall 6 150mm Stove to Corner Wall 6 150mm Stove to Right Side Wall 6 150mm Stove to Ceiling 30 760mm Stove to Rear Wall 6 150mm Stove to 10 Deep Mantel 30 760mm Max Alcove Depth 24 610mm F 30 760 mm G 3 H 1 760 mm 0 0 250 mm Max Sidewalls C
44. technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not be placed on or near the appliance Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that the control compartments burners and circulating air passageways of the appliance be kept clean WARNING Do not operate the appliance with the glass front removed cracked or broken Replacement of the glass should be done by a qualified service person WARNING Use only replacement glass part number 3 40 21001500 and glass gasket part number 3 44 00539 Do not use substitute materials Do not strike or slam the glass front Do not use abrasive cleaners Do not clean when hot Specifications MAI
45. tor operates The cooking burner Ignition Module will stop sparking See the instructions on pages 19 20 for details on changing batteries 28 Maintenance INSPECTING THE VENTING An inspection of both the inner and outer vent pipes and the vent terminal should be made as part of the annual service appointment The venting must have no blockage and be in good repair The vent manufacturer s instructions may provide specific details on vent inspection Any vent sections that are disassembled must be reassembled and sealed as required This appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive dust or lint from carpeting bedding materials pets etc It is imperative that control compartments and circulating air passageways of this appliance be kept clean CLEANING THE LOGS BURNER AND FIREBOX During the annual inspection and maintenance appointment the service person should clean the logs embers burner and firebox To gain access to the firebox logs and burner follow the instructions on page 14 of this manual An extra soft brush should be used to gently clean the logs embers and burner as they are extremely fragile DO NOT USE A VACUUM CLEANER TO CLEAN THE LOGS EMBERS OR BURNER A vacuum cleaner may be used to clean the metal parts of the firebox Replace the logs and embers after cleaning Follow the instructions on pages 15 17 of this
46. ual horizontal run or equivalent horizontal run if two or three elbows are used and read the settings for the inlet air restrictor A E and exhaust restrictor 0 8 Examples are shown below and on page 9 The FireLuxe is shipped with a Simpson DuraVent GS starter section that is specifically designed for the FireLuxe Regardless of the venting brand you chose you must use the provided DuraVent starter section All of the venting brands listed for use with the FireLuxe are compatible with the provided starter section For venting system installation details refer to the instructions provided with the venting system you have chosen Each brand has specific installation requirements that must be followed to insure a safe and functional venting system for your FireLuxe Note The FireLuxe is shipped from the factory with restrictor settings for 2 feet of vertical rise and 1 foot of horizontal run and for the fuel type listed on the rating plate attached to the rear of the stove Example 1 Fuel Propane LP QS Vertical Rise 15 feet M Exhaust Horizontal Run 8 feet ox Elbows 1 one Equivalent Horizontal Run 8 feet Air Restrictor Setting E72 Exhaust Restrictor Setting 6 Example 2 Fuel Propane LP Vertical Rise 6 feet Horizontal Run 7 8 feet Elbows 3 three if Equivalent Horizontal Run 16 feet 8 4 4 e 3 Air Restrictor Setting C Exhaust Restrictor Setting amm Exhaust Inlet Air
47. ully press the new glass panel gasket assembly into the glass frame by first inserting the top edge under the two gasket retainers and then pressing the sides and bottom edge into the frame 9 Carefully pick up the glass and glass frame assembly by grasping the sides of the frame and using your thumbs and fingers to hold the glass in place within the gasket and frame 10 With the glass frame and glass at a slight angle leaving room for your fingers between the frame and the firebox insert the bottom edge of the frame into the frame retainer located on the bottom front of the firebox Take care to center the frame from left to right Once the bottom edge is in place move your fingers out of the way and press the top of the frame against the firebox while pushing down to be sure the frame is fully engaged in the frame retainer Hold the frame in place with one hand and engage the three glass frame latches by pulling out and down while hooking them over the frame 11 Replace the Stove Front and Stove Top See instructions on page 18 CLEANING THE GLASS WARNING Never clean the glass while it is hot Do not use abrasive cleaners or cleaners containing ammonia NOTE A micro fiber cleaning cloth and plain water is recommended by the glass manufacturer BATTERY REPLACEMENT When the batteries need replacement the remote handset shows a low battery indicator BATT The Ignition and Control Module will give three short beeps when the valve mo
48. ustible materials including the mantel must be in conformance with the clearances shown on Page 6 of this manual A special adapter and components are required to convert the co axial rear vent starter to a co linear configuration that will allow separate 3 diameter flexible metal ducts one for the air and one for the exhaust to pass through the damper opening in the fireplace and to run to the top of the chimney A second special adapter is required at the top of the chimney to rejoin the flexible ducts back to a co axial configuration and allow the use of standard vertical vent caps This chimney top adapter must be sealed to the top of the chimney to prevent air leakage Check with the installer or venting manufacturer to see if they have the needed components or kits for this type of installation Also check the vent manufacturer s installation instructions for the specific details and requirements for this type of installation Note Some gas stove manufacturers allow the air duct to terminate a few feet above the fireplace damper This is not allowed for the FireLuxe Both the air duct and the exhaust duct must run the full length from the stove adapter to the chimney top adapter When venting through a fireplace the air and exhaust restrictors should be set using the charts below The minimum vent rise allowed is 10 feet The maximum vent rise is NATURAL GAS PROPANE LP GAS 35 feet Use the settings on the Vert Rise Vert Rise charts that