1. Space to the floor 15 Tools for installation 1 Level meter 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 13 Inner hexagon spanner 12 Universal meter 14 Measuring tape e Please contact the local agent for installation e Don t use unqualified power cord Selection of installation location Basic requirement Installing the unit in the following pla ces maycause malfunction If it is un avoidable please consult the local dealer 1 The place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances 7 The appliance shall not be install ed in the laundry Indoor unit There should be no obstruction near air inlet and air outlet Select a location where the condensat ion water can be dispersed easily and won t affect other people Select a location which is convenient to connect the outdoor unit and near the power socket Select a location which is out of reach for childre
2. Step five connect the pipe of indoor unit 1 Aim the pipe joint at the corresponding OR bellmouth er pipe joint union nut 2 Pretightening the union nut with hand 3 Adjust the torque force by referring to the following sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tighten the union nut with torque wrench 19 Installation of indoor unit open end Hex nut diameter Tightening torque N m wench 6 1520 union nut 9 52 30 40 40 55 torque wrench pipe a indoor pipe 4 Wrap the indoor pipe and joint of con nection pipe with insulating pipe and then wrap it with tape insulating pipe Step six install drain hose 1 Connect the drain hose to the outlet pipe of indoor unit drain hose outlet pipe 2 Bind the joint with tape eae rid i tape Note drain hose e Add insulating pipe in the indoor N drain hose in order to prevent DD condensation SS e The plastic expansion particles are not provided MEAR PPE Step seven connect wire of indoor unit panel 1 Open the panel remove the screw on the wiring cover and then take down the cover k wiring cover 20 Installation of indoor unit 2 Make the power connection wire go through the cable cross ho
3. This button is used for setting Fan Speed in the sequence that goes from AUTO at af aad aal to De j p then back to Auto Auto gt a gt a al asi asl aa Low speed a Low Medium speed aMi Medium speed ad Medium High speed atil High speed swine Press this button to set up amp down swing angle which circularly changes as below Sb Was gt l gt l gt I I l A ve lt gt J lt zl This remote controller is universal If any command E or zl is sent out the unit will carry out the command as gt I N gt I indicates the guide louver swings as I gt l O FEEL Press this button to turn on FEEL function The unit automatically adjust temperature according to the sensed temperature Press this button again to cancel FEEL function Introduction for buttons on remote controller A Press this button to achieve the on and off of healthy and scavenging functions in operation status Press this button for the first time to start scavenging function LCD displays Press the button for the second time to start healthy and scavenging functions simultaneously LCD displays and Press this button for the third time to quit healthy and scavenging functions simultaneously Press the button for the fourth time to start healthy function LCD display Pressthis button again to repeat the operation above Air function is applicable for some
4. the parts Is electric wiring and pipeline installed correctly Is the unit grounded securely It may cause electric leakage It may cause malfunction or damaging the parts Does the power cord follow the speci fication Is there any obstruction in the air inlet It may cause insufficient cooling and outlet heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of It may cause insufficient cooling connection pipe are open completely heating capacity Test operation 1 Preparation of test operation e The client approves the air conditioner e Specify the important notes for air conditioner to the client 2 Method of test operation e Put through the power press ON OFF button on the remote controller to start operation e Press MODE button to select AUTO COOL DRY FAN and HEAT to check whether the operation is normal or not e f the ambient temperature is lower than 16 C the air conditioner can t start cooling 23 Configuration of connection pipe 1 Standard length of connection pipe e 5m 7 5m 8m 2 Min length of connection pipe is 3m 3 Max length of connection pipe and max high difference Cooling mee cus Max height Cooling Aa Aeng Max height of connec of connec capacity Honipipe difference capacity tion pipe difference 5000Btu h 24000Btu h 1465W Ue 7032W F 7000Bt
5. 3 At this time 1hour will be automatically increased at the timer postion on the remote control that are 2hours or 3hours or 8hours the place of setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink 4 Repeat the above step 2 3 operation until 8hours temperature setting finished sleep curve setting finished at this time the remote control will resume the original timer display temperature display will resume to original setting temperature Sleep3 the sleep curve setting under Sleep mode by DIY could be inquired The user could accord to sleep curve setting method to inquire the presetting sleep curve enter into user individuation sleep setting status but do not change the temperature press Turbo button directly for confirmation Note In the above presetting or enquiry procedure if continuously within10s there is no button pressed the sleep curve setting within 10s there is no button pressed the sleep curve setting status will be automatically quit and resume to display the original displaying In the presetting or enquiry procedure press ON OFF button Mode button Timer button or Sleep button the sleep curve setting or enquiry status will quit similarly Introduction for buttons on remote controller TEMP Press this button you can see indoor set temperature indoor ambient temperature on indoor unit s display The setting on remote controll
6. a normal phenomenon e The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon e This is the sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature Malfunction analysis e When air conditioner status is abnormal temperature indicator on indoor unit will blink to display corresponding error code Please refer to below list for identific ation of error code Bor code Above indicator diagram is only for reference Please refer to indoor actual product for the actual display indicator and position Below listed error codes are only part error codes Please refero to error code list in serive manual for more information Error code Troubleshooting Defrosting indicator NO E5 U8 H6 C5 F1 F2 Warning m When below phenomenon occurs please turn off air conditioner and discon nect power immediately and then contact the dealer or qualified professionals for service e Power cord is overheating or damaged e There s abnormal sound during operation e Circuit break trips off frequently e Air conditioner gives off burning smell e Indoor unit is leaking m Do not repair or refit the air conditioner by yourself m f the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Installation dimension diagram i Space to th
7. and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby Step three open piping hole 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame shown as below OOK 12K Wall Y 1Space to the wall above 150mm gt G he Us D rife N i 0 z 9 gt 1 Es l a _ 2 55mm 55mm Rear piping hole Rear piping hole Rear piping hole Rear piping hole 2 Open a piping hole with the diameter of 55 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 18 Installation of indoor unit outdoor Note e Pay attention to dust prevention and take relevant safety measures when opening the hole e The plastic expansion particles are not provided and should be bought locally Step four outlet pipe 2 When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case left right I I I I rear left I cut off the hole 1 The pipe can be led out in the direction of right rear right left or rear left
8. clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommended to use a soft dry cloth or wet cloth to wipe it Note e Do not remove the panel when cleaning it Clean and Maintenance Clean filter Open panel Clean filter Pull out the panel to a certain e Use dust catcher or water to angle as shown in the fig clean the filter e When the filter is very dirty use the water below 45 C to clean oe it and then put it in a shady _ eR ee es and cool place to dry Remove filter Remove the filter as in dicated in the fig Install filt nstall Titer Install the filter and then close the panel cover tightly SSS TES m The filter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased m After removing the filter do not touch fins to avoid injury m Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard Clean and Maintenance Checking before use season Check whether air inlets and air outlets are blocked Check whether air switch plug and socket are in good condition Check whether filter is clean Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dea
9. displayed T ON T OFF Press T ON button to initiate the auto ON timer To cancel the auto timer program simply press this button again After press of this button O disappears and ON blinks 00 00 is displayed for ON time setting Within 5 seconds press or button to adjust the time value Every press of either button changes the time setting by 1 minute Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes Within 5 Seconds after setting press TIMER ON button to confirm Press T OFF button to initiate the auto off timer To cancel the auto timer program simply press the button again TIMER OFF setting is the same as TIMER ON TURBO Press this button to activate deactivate the Turbo function which enables the unit to reach the preset temperature in the shortest time In COOL mode the unit will blow strong cooling air at super high fan speed In HEAT mode the unit will blow strong heating air at super high fan speed LIGHT Press LIGHT button to turn on the display s light and press this button again to turn off the display s light If the light is turned on 0 is displayed If the light is turned off W disappears Introduction for buttons on remote controller 15 X FAN Pressing X FAN button in COOL or DRY mode the icon is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit
10. to ensure they are away from the appliance This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from un controlled waste disposal recycle it responsibly to promote the sustainable reuse of mate rial resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for envi ronmental safe recycling Precautions e Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard e Do disconnect power supply when cleaning air conditioner Otherwise it may cause electric shock e Do not spray water on indoor unit It may cause electric shock or malfunction e Do not spill water on the remote controller otherwise the remote controller may be broken e Do not repair air conditioner by yourself It may cause electric shock or damage Please contact dealer when you need to repair air conditioner e Do not block air inlet It may cause malfunction e If you need to relocate the air conditioner to another place only the qualified person can perform the work Otherwise it may cause personal injury or damage e Do not extend fingers or objects into air inlet or It may cause personal injury or damage e Air Conditioner should be properly grounded Incorrect grounding may cause electricshock e D
11. After energization X FAN OFF is defaulted X FAN is not available in AUTO FAN or HEAT mode Combination of and buttons About lock Press and buttons simultaneously to lock or unlock the keypad If the remote controller is locked is displayed In this case pressing any button m blinks three times 17 Combination of MODE and buttons About switch between Fahrenheit and centigrade At unit OFF press MODE and buttons simultaneously to switch between C and F 18 Combination of TEMP and CLOCK buttons About Energy saving Function Press TEMP and CLOCK simultaneously in COOL mode to start energy saving function Nixie tube on the remote controller displays SE Repeat the operation to quit the function 19 Combination of TEMP and CLOCK buttons About 8C Heating Function Press TEMP and CLOCK simultaneously in HEAT mode to start 8 C Heating Function Nixie tube on the remote controller displays and a selected temperature of 8 C 46F if Fahrenheit is adopted Repeat the operation to quit the function 2 0 About Back lighting Function The unit lights for 4s when energizing for the first time and 3s for later press Replacement of batteries in remote controller 1 Remove the battery cover plate from the rear of the remote controller As shown in the figure 2 Take out the old batteries 3 Insert two new AAA1 5V dry batteries and pay attention
12. USER S MANUAL SINCLAIR AIR CONDITIONING Original instructions Content Operation Notices FS CONN sarees eaace carters tearndevavncestnte seer tie ccersraanpirsionttens acini ai aAa iS a E 1 FAG SS IN ANON cesar accent cts ns sors ho E E anna E E A E EATA 2 Screen Operation Guide Buttons on remote Controller ccc ccc ccc eceseeseceeseceeeueeaueueesauseeeusaueauaeeevaneaeens 3 Introduction for buttons on remote controller pp 4 Replacement of batteries in remote controller pp 7 Emergency operation pp 8 Maintenance Cleah and Nalnienanee saeerste cigs inniinn aniani E iaie 8 Malfunction WAT CTCF analysis sstestntodasniieeedaninesersecnedsienacedatiacundieBeneigabanadaiiendadinatnenacekedeaaienstaannents 11 Installation Notice Installation dimension diagram pp 15 TOOIS for instalat OM go peisat acco catesadaccecesancaa neen eaaa iiaii 16 Selection of installation location pp 16 Requirements for electric connection pp 17 Installation HS TANATIOT OP ndoor UMs iaria eA Eiin 18 Check after installation 7 23 Test and operation TS SEO OM we 23 Attachment Configuration OF connection pipe pp 24 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised
13. e crossed or winding e The drain hose should be bound at the bottom 2 Reserve a certain length of drain hose and power cord for installation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose i Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and closed to the wall indoor outdoor upper hook wall pipe LAFE ELLA K f lower hook of wall mounting frame Note e Do not bend the drain hose too excessively in order to prevent blocking 22 Check after installation e Check according to the following requirement after finishing installation Items to be checked Possible malfunction Has the unit been installed firmly The unit may drop shake or emit noise Have you done the refrigerant leakage It may cause insufficient cooling test heating capacity It may cause condensation and water dripping It may cause condensation and water dripping Is heat insulation of pipeline sufficient Is water drained well Is the voltage of power supply accord ing to the voltage marked on the nameplate It may cause malfunction or damaging the parts It may cause malfunction or damaging
14. e properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comply with national electric safety regulations 4 The appliance must be positioned so that the plug is accessible 5 An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring 6 Including an air switch with suitable capacity please note the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit ile Installation of indoor unit Step one choosing installation location Recommend the installation location to the client and then confirm it with the client Step two install wall mounting frame 1 Hang the wall mounting frame on the wall adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall 2 Drill the screw fixing holes on the wall with impact drill the specification of drill head should be the same as the plastic expansion particle and then fill the plastic expansion particles in the holes 3 Fix the wall mounting frame on the wall with tapping screws ST4 2X25TA
15. e valuable natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of later regulations In case of incorrect disposal of this waste a fine can be imposed according to national regulations Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purkynova 45 612 00 Brno Czech Republic www hnepa Ccz Toll free info line 420 800 100 285 CE
16. er is selected circularly as below no display pa Y D When selecting A with remote controller or no display temperature indicator on indoor unit displays set temperature When selecting Q with remote controller temperature indicator on indoor unit displays indoor ambient temperature 3s later or within 3s it receives other remote control signal that will return to display the setting temperature Caution e This model hasn t outdoor ambient temperature display function While remote controller can operate Q and indoor unit displays set temperature e Its defaulted to display set temperature when turning on the unit e Only for the models with temperature indicator on indoor unit Press this button the Quiet status is under the Auto Quiet mode display 4 signal and Quiet mode display Gp singal and Quiet OFF there is no signal of G displayed after powered on the Quiet OFF is defaulted Note the Quiet function cannot be set up in Fan and Dry mode Under the Quiet mode Display G Under the Quiet mode the fan speed is not available CLOCK Press CLOCK button blinking Within 5 seconds pressing or button adjusts the present time Holding down either button above 2 seconds increases or decreases the time by 1 minute every 0 5 second and then by 10 minutes every 0 5 second During blinking after setting press CLOCK button again to confirm the setting and then C will be constantly
17. is reached to set temperature the plug after about 3min and then turn on the unit again e Signal receiving range is 8m e Remove obstacles e Select proper angle and point the remote controller at the re ceiving window on indoor unit e Check the batteries If the power of batteries is too low please replace them e Check whether remote cont roller appears to be damaged If yes replace it e Take the remote controller close to indoor unit e Turn off the fluoresent lamp and then try it again e Eliminate obstacles e After reaching to set temper ature indoor unit will stop bl owing out air e Heating mode is turned on just e In order to prevent blowing now 11 out cold air indoor unit will be started after delaying for sev eral minutes which is a nor mal phenomenon Malfunction analysis Phenomenon Check items Solution e Power failure e Wait until power recovery e Is plug loose e Reinsert the plug e Air switch trips off or fuse is e Ask professional to replace burnt out air switch or fuse ES o Wiring has malfunction e Ask professional to replace it ioner can t operate e Unit has restarted immediately after stopping operation e Wait for 3min and then turn on the unit again e Whether the function setting for remote controller is e Reset the function correct e Because indoor air is cooled rapidly After a while indoor temperature and humidity
18. le at the back of indoor unit and then pull it out from the front side 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip wiring board grounding wire 07 09 12 18K Heat Pump Type outdoor unit connection wire clip Note the wiring board is for reference only please refer to the actual one 4 Put wiring cover back and then tighten the screw 5 Close the panel Note e All wires of indoor unit and outdoor unit should be connected by a professional e f the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself e For the air conditioner with plug the plug should be reachable after finishing installation e For the air conditioner without plug an air switch must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm 21 Installation of indoor unit Step eight bind up pipe 1 Bind up the connection pipe power cord and drain hose with the band connection pipe drain hose band indoor and outdoor power cord indoor unit J SG indoor power cord 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end Note e The power cord and control wire can t b
19. ler Check whether drainage pipe is damaged Checking after use season Disconnect power supply Clean filter and indoor unit s panel Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner please contact local dealer or consultant service center for the correct disposal method 10 Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance If the malfunction still can t be eliminated please contact local dealer or qualified professionals Phenomenon Indoor unit can t receive remote controller s signal or remote controller has no action No air emitted KOAA indoor unit Check items Solution e Whether it s interfered severely e Pull out the plug Reinsert such as static electricity stable voltage e Whether remote controller is within the signal receiving range e Whether there are obstacles e Whether remote controller is pointing at the receiving window e Is sensitivity of remote contro ller low fuzzy display and no display e No display when operating remote controller e Fluorescent lamp in room e Air inlet or air outlet of indoor unit is blocked e Under heating mode indoor temperature
20. models SLEEP e Press this button can select Sleep 1 Sleep2 Sleep 3 and cancel the Sleep circulate between these after electrified Sleep Cancel is defaulted e Sleep 1 is Sleep mode 1 in Cool mode after run for one hour in sleep mode the main unit setting temperature will increase 1 C after 2 hours the setting temperature will increase 2 C but the maximal setting temperature is 30 C then the unit will run at this setting temperature all along In Heat mode after run for one hour in sleep mode the setting temperature will decrease 1 C after 2 hours the setting temperature will decrease 2 C but the minimal setting temperature is 16 C then the unit will run at this setting temperature all along e Sleep 2 is sleep mode 2 that is air conditioner will run according to the presetting a group of sleep temperature curve Sleep 3 the sleep curve setting under Sleep mode by DIY 1 Under Sleep 3 mode press Turbo button for a long time remote control enters into user individuation sleep setting status at this time the time of remote control will display 1hour the setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of original factory 2 Adjust and button could change the corresponding setting temperature after adjusted press Trubo button for confirmation
21. n The location should be able to withstand the weight of indoor unit and won t incr ease noise and vibration The appliance must be installed 2 5m above floor Don t install the indoor unit right above the electric appliance Please try your best to keep way from fluorescent lamp 16 Requirements for electric connection Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supply circuit and air switch 3 Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Please install proper power supply cables before using the air conditioner 4 Properly connect the live wire neutral wire and grounding wire of power socket 5 Be sure to cut off the power supply before proceeding any work related to electricity and safety 6 Do not put through the power before finishing installation 7 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations Grounding requirement 1 The air conditioner is the first class electric appliance It must b
22. o install the air switch If not it may cause malfunction e Installation and maintenance must be performed by qualified professionals Otherwise it may cause personal injury or damage Working temperature range FL Indoor side DB WB C_ Outdoor side DB WB C 32 23 43 26 Maximum heating 24 18 e The operating temperature range outdoor temperature for cooling only unit is 18 C 43 C for heat pump unit is 10 C 43 C Parts Name Indoor Unit air inlet filter air outlet heating indicator defrosting indicator horizontal louver temp indicator cooling indicator drying indicator power indicator Display content or position may be different from above remote controller graphics please refer to actual products Actual product may be different from above graphics please refer to actual products Buttons on remote controller Operation mode i Auto mode Cool mode Dry mode Fan mode a ray a E e es Heat mode ON OFF button button MODE button FAN button SWING button FEEL button 4 button SLEEP button TEMP button QUIET button CIOCK button Note This remote controller is universal and can be used for multi functional air conditioning If the button on the remote contr
23. oller with the function which the air conditioner doesn t have is pressed the unit remains in its original operating mode T ON T OFF button TURBO button X FAN button LIGHT button Pee i Send signal e Healthy mode Scavenging functions 8 C heating function a Set temperature X FAN function Set time TIMER ON TIMER OFF Introduction for buttons on remote controller ON OFF Press this button to turn on the unit Press this button again to turn off the unit Press this button to decrease set temperature Holding it down above 2 seconds rapidly decreases set temperature In AUTO mode set temperature is not adjustable a Press this button to increase set temperature Holding it down above 2 seconds rapidly increases set temperature In AUTO mode set temperature is not adjustable MODE Each time you press this button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT as the following AUTO B COOL gt DRY P FAN PHEAT i Note Only for models with heating function After energization AUTO mode is defaulted In AUTO mode the set temperature will not be displayed on the LCD and the unit will automatically select the suitable operation mode in accordance with the room temperature to make indoor room comfortable As for cooling only unit it won t have any action when it receives the signal of heating operation FAN
24. to the polarity 4 Reinstall the battery cover plate Notes When replacing the batteries do not use old or different types of batteries otherwise it may cause malfunction r e Ifthe remote controller will not be used for a long time please remove batteries to prevent batteries from leaking The operation should be performed in its receiving range It should be kept 1m away from the TV set or stereo sound sets Sketch map for Ifthe remote controller does not operate normally please take the replacing batteries batteries out and reinsert them after 30 seconds If it still can t operate properly replace the batteries Emergency operation lf remote controller is lost or damaged please use auxiliary button to turn on or turn off the air conditioner The operation in details are as below As shown in the fig Open panel press aux button to turn on or turn off the air conditioner When the air conditioner is turned on it will operate under auto mode panel aux button Clean and Maintenance m Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock m Do not use volatile liquid to
25. u h 28000Btu h 2051W 8204W 30 10 9000Btu h 36000Btu h T 2637W 10548W 12000Btu h 42000Btu h a 3516W 12306W 48000Btu h 48000Btu h 5274W 14064W 4 The additional refrigerant oil and refrigerant charging required after prolonging connection pipe e After the length of connection pipe is prolonged for 10m at the basis of standard length you should add 5ml of refrigerant oil for each additional 5m of connection pipe e The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe x additional refrigerant charging amount per meter e When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet 24 Configuration of connection pipe Additional refrigerant charging amount for R410A Take back of electrical waste Information for Users to Disposal of electrical and electronic equipment private households Icon on the product or in the accompanying documentation means that used electric or electronic products must not be disposed together with domestic waste For the correct disposal of the product hand it over to a place for take back where it is collected free of charge By correct disposal of the product you can help to preserv
26. will be decrease and mist will disappear Mist is em itted from e Indoor temperature and hum indoor unit s idity is high air outlet e Temperature can t be adju sted under auto mode de Please switch the operation Set temper RFI mode if you need to adjust ature can t temperature be adjusted e Unit is operating under auto e Your required temperature exceeds the set temperature range e Set temperature range Wee S10 e Wait until the voltage e Voltage is too low resumes normal Cooling e Filteris dirty e Clean the filter heating effect is not good e Set temperature is in proper e Adjust temperature to proper range range e Door and window are open e Close door and window 12 Malfunction analysis Phenomenon Odours are emitted Air conditioner operates abno rmally Outdoor unit has vapor Water flowing noise Cracking noise Check items e Whether there s odour source such as furniture and cigarette etc e Whether there s interference such as thunder wireless devices etc e Heating mode is turned on e Air conditioner is turned on or turned off just now e Air conditioner is turned on or turned off just now 13 Solution e Eliminate the odour source e Clean the filter e Disconnect power put back power and then turn on the unit again e During defrosting under he ating mode it may generate vapor which is