Home
FP-3710T Series Installation Guide - Pro
Contents
1. A TFT Color LCD Acts as a display monitor for your host B Touch Panel Allows you to switch screens or write data to the host C Power Connector Socket Provides the input and ground terminals for a power cable D Setting Switch By opening the cover the Dip switches and slide switch are seen Each switch can set a operation mode E Analog RGB Connector Connector for analog RGB interface F DVI D Interface Connector Connector for DVI D interface G Serial Connector Connector for serial RS 232C interface Used for sending touch panel data to the host H USB Connector Type B Connector for USB interface Used for sending touch panel data to the host or used as an upstream port for USB HUB I Front LED Used to indicate the condition of the power supply a backlight burnout or image signal input J Front USB Connector Type A FP3710 T42 U and FP3710 T42 24V U A downstream port for embedded USB HUB in conformity with USB2 0 1 1 standard which is used for connecting USB devices Connect the upstream port of the USB HUB H USB connector to the Host PC for Front USB connector use Dimensions Unit mm in pene 395 15 55 60 2 36 294 11 57 iy N f N Front View Side View Dip Switches and Slide Switch The Dip Switches and Slide Switch are located in the bottom of the FP unit Only the settings when the power supply is turne
2. Item Function Color Settings Adjusts the contrast and the brightness Screen Settings Adjusts the display position of the screen Custom Display Adjusts Sharpness and the backlight brightness System Settings Changes settings such as activating the click sound All Reset Resets the current OSD value to the default value Input Source Switches Analog RGB and DVI D A Automatically adjusts the display position of the screen Auto Adjust Analog RGB only Auto Gain Automatically adjusts the contrast and the brightness Analog RGB only ESC Cancels the setting and returns to the upper level SET Applies the setting and returns to the upper level Arrow KEY Changes the selection SELECT Selects icons or items SAVE Saves the current value and quits the OSD EXIT Quits the OSD E Starting the OSD To start the OSD and enter OSD mode press the three corners of the touch panel in turn upper left upper right and lower right within 5 seconds In OSD mode the setting screen is displayed in the center of the screen In this mode the touch panel cannot be used to export data to external devices unless the settings for the OSD are completed OSD is not displayed when a SW 1 2 is ON m Using the OSD Icons on the screen are used to operate the OSD After the OSD start up the top menu di
3. m Electrical Specification Item Specification DC TYPE AC TYPE Rated Voltage DC24V AC100 to 240V Allowable Voltage DC19 2 to 28 8V AC85 to 264V gt Rated Frequency 50 60HZ g Allowable Frequency Rangel 40 72Hz a 1 cycle Max Voltage drop 5 Allowable Voltage Drop 5ms or less interval must be 1s or more 3 AC100V 1 14 or less a A TYP0 75A Current Consumption 40W or less AC240V 0 7A or less TYP0 44A In Rush Current 30A or less 60A or less AC1000V 20mA for 1 minute AC1500V 20mA for 1 minute Voltage Endurance between charging and FG between charging and FG terminals terminals DC500V 10MA or more DC500V 10MQ or more Insulation Resistance between charging and FG between charging and FG terminals terminals 9 m Environmental Specification Item Specification Surrounding Air Temperature Storage Temperature 20 to 60 C Ambient Humidity 10 to 90 RH Storage Humidity No condensation Wet bulb temperature 39 C max 0 to 50 C The panel should not incline more than 30 Air Purity Dust 0 1mg m Max No electrically conductive dust is allowed Pollution Degree For use in Pollution Degree 2 environment 1 Wiring the DC type power supply cable Pa Accompanying DC type power m Power Cord Specifications supply connector is CA7 DCCNL Use copper conductors only 01 from Pro face or GFKC2 5 3 STF 7 62 is manufactured
4. eee Dsub 9 pin female Connector set screw Inch type 4 40UNC BING E SIO cable for FP manufactured by Pro face FP61V 1S00 O Concerning Signal Names Signal names used for the serial interface on FP units are designed to match the pin order used on most PC serial interfaces so that a straight cable can be used to connect the two Therefore connect each pin s signal to the same signal name on the PC side For example pin 2 RD should be connected to the RD input terminal on the PC s connector Refer to the FP3000 Series User Manual s section Cable Diagrams for each signal s direction m USB Interface Type B connector Up Stream Port Pin Assignments and Signal Names for USB Interface Pin No Signal Name Condition Pin Location USB1 5V 5VIN USBD1 USB data USBD1 USB data AJOJN GND Ground USB cable manufactured by Pro face FP US00 If a cable other than the specified USB cable is used product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit s operation Installation 1 According to the Panel Cut size make installation holes on the panel Also determine the panel thickness according to the panel thickness range with due consideration of panel strength Unit mm in Panel r lt 3 0 12 thickness
5. 5 m gt FP DV01 100 lt 10 m gt Ifa cable other than the specified DVI D cable is used product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit s operation Only when the FP 3710T series is connected with PS 2000B or PL 3000B Revision B or more FP DV01 100 can be used Please turn on PS 2000B s internal dipswitch 4 when you use FP DV01 100 with PS 2000B The resolution that can be displayed is 1024 x 768 only XGA Please turn off dipswitch 4 when you use FP DV01 50 Please set PL 3000B s internal dipswitch 5 to sign side when you use FP DV01 100 with PL 3000B We will recommend the resolution of PL 3000B to change to the maximum display resolution of FP additionally Please set it on the opposite side of e sign when you use FP DV01 50 E Serial Interface Baud rate 9600 bps Data length 8 bits RS 232C Serial Interface Parity None Stop bit 21 Flow Control None Pin Assignments and Signal Names for Serial Interface Pin No Signal Name Condition Pin Location 1 cD Carrier Detect 2 RD Receive Data FP gt Host 3 SD Send Data FP lt Host 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RS Request to Send FP lt Host 8 cs Clear to Send FP gt Host 9 NC Used internally 1 The CD DTR and DSR are connected together inside of the FP Connector uu
6. FP X Y Panel thickness di 1 0 as 388 597 28259 lie 0 06 to eries 15 104004 11 124004 10 0 0 39 2 Check that FP has installation fasteners Insert the FP from the front Installation gasket must be used even though it is not necessary for its environment For installation refer to FP3000 Series User Manual Check that the installation panel or cabinet s surface is flat in good condition and has no jagged edges Also if desired metal reinforcing strips can be attached to the inside of the panel near the Panel Cut to increase the panel s strength 8 he 3 The following figures show the eight 8 fastener insertion slot locations Insert each fastener s hook into the slot and tighten it with a screwdriver Top Installation fastener Panel FP Hook Left side Bottom Right side Tightening the screws with too much force can damage the FP unit s case The necessary torque is 0 5 Nem 4 4 Ib in Wiring WARNING To avoid an electric shock when connecting the FP s power cord terminals to the power terminal block confirm that the FP s power supply is completely turned OFF via a breaker or similar unit To avoid the dangers of fire electric hazards and equipment damage be sure to use only the specified voltage when operating the FP Since there is no power switch on the FP unit be sure to attach a breaker type switch to its power cord
7. N ae O DFG S 4 After inserting all three pins insert the Power Plug into the Power Con nector at FP Fix the plug with two 2 minus screws IMPORTANT Confirm that all wires are connected correctly The torque required to tighten these screws is 0 5 to 0 6 Nem 4 4 to 5 3 Ib in To prevent the possibility of a termi nal short use a pin terminal that has an insulating sleeve Using the USB Cable Clamp m USB Cable Clamp Attachment Procedure Installation to USB cable 1 Connect the USB cable to the connector 2 Insert the cable clamp into the cable clamp holder as shown in the following figure and tighten the clamp until the cable is secured in place USB USB cable Cable clamp Stopper USB cable clamp holder 0 USB Cable Clamp Removal Feature Push in the cable clamp s stopper until the cable clamp is unlocked then remove the clamp Disconnect the USB cable 1 2 Power Supply Cautions Please pay special attention to the following instructions when connecting the power cord terminals to the FP unit Ifthe power supply voltage exceeds the FP unit s specified range connect a voltage transformer Between the line and the ground be sure to use a low noise power supply If there is still an excessive amount of noise connect a noise reducing transformer Input and Output signal lines must be separated from the power control cables for operat
8. RGB only gt H size Analog RGB only gt Phase Analog RGB only gt Display Clock Clock for output to TFT color display can be finely adjusted according to 9 levels Default 50 E eae Adjustment button Adjustment button A _ Please use to the default value normally Applies the setting and then returns to the top menu p Cancels the setting and then returns to the top menu ce Custom Display Selection of the change item Ly Sharpness gt Dimmer 13 Auto Adjust Enable Ly OSD Transparent Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu Adjustment button 14 mu System Settings gt Ti Selection of the change item Adjustment button 2 Click Tone Enables disables the click sound With this i parameter the sound level can also be adjusted Default value OFF lt Click sound disabled gt I 720x400 Mode When an input data resolution of 720 x 400 is used in the VGA text mode set this parameter to ON For other resolutions set this parameter to OFF Default ON P A ff Di Enables disables the screen display Auto OFF ee function and sets the time when the Auto OFF function is enabled Default OFF lt Auto OFF function disabled gt The Auto OFF function automatically turns off the display to prevent the screen f
9. The FP 3710T Series unit needs the following software for operation As FP user manual provided by PDF media describes its details download the manual below and get the further information Visit Pro face website below and get both software De ee ee FP 3710T Series Installation Guide et Caution Be sure to read the Warning Caution Information on the attached sheet before using the product Package Contents E FP unit 1 E Installation Guide 1 this manual m Warning Caution Information 1 E Installation Gasket 1 attached to the FP unit E Installation Fasteners 4 set 2sets m USB Cable Clamp 1 mPower Plug 1 attached to the FP unit DC type This unit has been carefully packed with special attention to quality However should you find anything damaged or missing please contact your local FP distributor immediately Required software Reference manual and reference manual URL http www pro face com otasuke Software Mouse Emulation Software FP3000 Series User Manual Manual Installation prerequisites for standards For the detailed certification s information refer to the Pro face Home page lt Cautions gt Be aware of the following items when building the FP into an end use product For indoor use only This unit should be installed in the front face of a metal panel If this unit is installed so as to cool
10. aka 559 0031 Japan losses resulting from the use of this URL http www pro face com product The information in this document is subject to change without notice PFX122672K FP3710 MT23E BTH 2012 3 SS B 2011 Digital Electronics Corporation 16 Addendum Anexo Annexe PHA99478 08 2018 California Proposition 65 Warning Lead and Lead Compounds Advertencia de la Proposicion 65 de California Plomo y compuestos de plomo Avertissement concernant la Proposition 65 de Californie Plomb et compos s de plomb AXWARNING This product can expose you to chemicals including lead and lead compounds which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov All trademarks are the property of Schneider Electric SE its subsidiaries and affiliated companies Schneider Electric USA Inc 800 Federal Street Andover MA 01810 USA 888 778 2733 www schneider electric us ADVERTENCIA Este producto puede exponerle a qu micos incluyendo plomo y compuestos de plomo que es son conocido s por el Estado de California como causante s de c ncer y defectos de nacimiento u otros da os reproductivos Para mayor informaci n visite www P65Warnings ca gov Todas las marcas comerciales son propiedad de Schneider Electric SE sus filiales y compa as afiliadas Importado en M xico por Sch
11. al type DVI D On un pedia DIMMER BACKLIGHT SHARPNESS ALL RESET DEFAULT Display Area Size H Sync V Sync DotClock Screen Resolution Expansion Display kHz Hz MHz H Horizontal V Vertical Resolution 640x400 24 827 56 000 21 053 x1 6 H 640x400 31 469 70 000 25 175 x1 92 V 640x480 31 469 59 992 25 175 640x480 35 000 66 667 30 240 16 640x480 37 500 75 000 31 500 720x400 1 31 469 70 000 28 320 erat 1024x768 800x600 37 879 60 317 40 000 PeR 800x600 46 875 75 000 49 500 i 1024x768 48 363 60 004 65 000 1024x768 56 476 70 069 75 000 x1 0 1024x768 60 023 75 029 78 750 Tl When you use this resolution set ON for 720 x 400 Mode in the OSD On Screen Display System Settings Pin Assignments and Signal Names for DVI D Pin Signal Name Pin Signal Name Pin Signal Name Pin Location 1 TMDS DATA2 9 TMDS DATA1 17 TMDS DATAO 2 TMDS DATA2 10 TMDS DATA1 18 TMDS DATAO 3 TMDS DATA2 11 TMDS DATA1 19 TMDS DATAO SHIELD SHIELD SHIELD oo 4 NC 12 NC 20 NC E 5 NC 13 NC 21 NC EA 6 DDCClock 14 NC 22 TMDS CLOCK hal 7 DDC Data 15 GND 23 TMDS CLOCK 8 NC 16 Hot Plug Detect 24 TMDS CLOCK Connector ccioconionicmcino DVI D 24 pin male Connector set screw Inch type 4 40UNC DVI D cable manufactured by Pro face FP DV01 50 lt
12. by Power Coid hngatowemie Phoenix Contact Diameter 18 to 12 AWG m Connecting the Power Cord 1 Confirm that the power is not sup Conductor Simple or Stranded plied to the FP unit Type Wire 2 Push the Opening button with a small and flat screw driver to open 10mm Conductor pe the desired pin hole Length 3 Insert each pin terminal into its each hole Release the Opening button to clamp the pin in place If the Conductor s end individual wires are Opening Button not twisted correctly the end wires may either DC power supply cord N short against each other or against an elec D each other or against an elec Oy D vn m Wiring 3 Flee When connecting the power cord use the S 7 following items when performing wiring 4 After inserting all three pins insert Items are made by Phoenix Contact 4 the Power Plug into he Poner Con Recommended nector at FP Fix the plug with two Driver SZS 0 6x3 5 1205053 2 minus screws Al 0 75 10GY 3201288 IMPORTANT Recommended Al 1 10RD 3200182 MRCRTANTI Pin Terminals Al 1 5 10BK 3200195 The torque required to tighten these Al 2 5 12BU 3200962 an is 0 5 to 0 6 Nem 4 4 to 5 3 in Recommended Pin Terminal CRIMPFOX ZA3 To prevent the possibility of a termi Crimp Too 1201882 nal short use a pin terminal that has an insulating sleeve 10 2 Wiring the AC type power s
13. d on is effective to the Dip Switches and the Slide Switch Turn off the power before changing the settings of this unit Bottom View EE Dip Switches SW1 Slide Switch SW2 m SW1 Switch Setting SW1 1 Reserved Always OFF SW1 5 Reserved Always OFF 12345678 ON SW1 2 Display Hide the OSD SW1 6 Reserved Always OFF lal lalo lolo lol lola SW1 3 Reserved Always OFF SW1 7 Reserved Always OFF SW1 4 Reserved Always OFF SW1 8 Reserved Always OFF e SW1 2 Dip Switch SW1 2 is used to display or hide the OSD To hide the OSD set the switch to ON To display the OSD set the switch to OFF The default setting is OFF OSD is displayed m SW2 Switch Setting st Slide Switch is used to switch the data input output command control method on the touch panel between a USB and RS 232C Serial The default setting is RS gt 232C Interfaces m Analog RGB Interface Input signal type Analog RGB Image signal analog RGB Input signal Synchronous signal TTL level negative true or positive true Scanning type non interlace CONTRAST A E H POSITION V Setting by OSD mare S PHASE On Screen Display DIMMER BACKLIGHT SHARPNESS ALL RESET DEFAULT The number of dots pixels displayed are as follows H Sync V Sync Dot Cloc
14. h Panel ID Set the touch panel ID number using the number 0 to 3 when connecting to USB Default 0 gt Applies the setting and then returns to the top menu gt Cancels the setting and then returns to the top menu 15 FA All Reset Resets all the settings and then returns to the top menu gt Cancels the setting and then returns to the top menu p Switches Analog RGB and DVI D and quits the OSD A Cancels the setting and then returns to the top menu ma Auto Adjust Analog RGB only i Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu a m IMPORTANT Be sure to perform the auto adjust while things except that black are shown on sides of the display ER Auto Gain Analog RGB only gt Ea Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu IMPORTANT Be sure to perform the auto gain control when the screen has both 100 black and 100 white areas displayed Icon decision Icon selection Saves the setting and quits the OSD Saves all the adjusted settings in the EEPROM End of OSD Note Regardless of the above clause Digital Digital Electronics Corporation Electronics Corporation shall not be i held responsible for any damages or 8 2 52 Nanko Higashi Suminoe third party claims for damages or ku Os
15. ional circuits The FP unit s power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal lines Connect a surge absorber to handle power surges To reduce noise make the power cord as short as possible The temperature rating of field installed conductors 75 C only 12 Must be used with a Class2 Power Supply FP3710 T42 24V U Grounding Caution When attaching a wire to the FP unit s rear face FG terminal on the AC Connector be sure to create an exclusive ground Use a grounding resistance of 1000 a wire of 2mm or thicker or your country s applicable standard Input Output Signal Line Cautions All FP Input and Output signal lines must be separated from all operating circuit power cables If this is not possible use a shielded cable and ground the shield Calibration of OSD Display Position m OSD Functions You can operate the FP screen menus via the touch panel and even if FP is operating adjust screen image display to a minute level The feature is called OSD On Screen Display The items that can be set with OSD and the functions are shown Example of OSD screen Eg Color Settings EERAABB a Bl Ver indicates tozex768ns0hz anaros The version of the redes OSD ee A e sme ext
16. it s front modules used in Class Division 2 Groups A B C and D hazardous locations from Doc No 35016429 FP s Front Module USB Pin Description 1Nec Nonincendive Field 2D Wiring Apparatus 3 D 4 GND See note 1 for detail Shield Gnd LL 12 34 Notes 1 Nonincendive Circuit Parameters Front USB I F Voc 5 0 V Isc 1 25 A Ca 10 uF La 16 pH 2 Selected Associated Nonincendive Field Wiring Apparatus shall satisfy the following Nonincendive Field Front module Wiring Apparatus of FP unit Voc lt Vmax Isc lt Imax Ca gt Ci C cable La gt Li L cable 3 If the electrical parameters of the cable are unknown the following values may be used Capacitance 60pF ft Inductive 0 20 1 H ft 4 Nonincendive Field Wiring must be installed in accordance with article 501 10 B of the National Electrical Code ANSI NFPA 70 5 Nonincendive Field Wiring Apparatus shall not contain or be connected to another source of power CE Marking Notes For the detailed information be downloaded and refer the Declaration of Conformity from Pro face Home Page The FP3710 T42 U and FP3710 T42 units are CE marked products that conform to EMC directives and Low Voltage directives e The FP3710 T42 24V U unit is CE marked products that conform to EMC directives Part Names Front View Rear View
17. itself naturally be sure to install it in a vertical panel Also be sure that the FP unit is mounted at least 100 mm away from any adjacent structures or equipment If these requirements are not met the heat generated by the FP unit s internal components may cause the unit to fail to meet UL c UL standard For use on a flat surface of a Type 4X Indoor Use Only and or Type 12 Enclosure Type 4X Indoor Use Only and or 12 Enclosure when the hatch for Front USB Port is secured by screw Type 1 Enclosure when the hatch for Front USB Port is open FP3710 T42 U FP3710 T42 24V U only Receivable signals are only from isolated secondary source All interface ports except for Front USB Connector Type A are not intended to be directly connected to a signal source greater than 30 volts and available current greater than 5mA lt Hazardous Locations Compliance and Handling Cautions gt WARNING Suitable for use in Class Division 2 Groups A B C and D Hazardous Locations or Nonhazardous Locations only WARNING Explosion hazard substitution of components may impair suitability for Class Division 2 Hazardous locations WARNING Explosion hazard do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations lt Control Drawing of USB I F on FP s Front Module gt The information below concerns the use of the USB I F located on the FP un
18. k Screen Resolution Display sie KHz H2 MHA Bo Horizontal V Vertical Resolution 640x400 24 827 56 000 21 053 x1 6 H 640x400 31 469 70 000 25 175 x1 92 V 640x480 31 469 59 992 25 175 640x480 35 000 66 667 30 240 aie 640x480 37 500 75 000 31 500 720x400 1 31 469 70 000 28 320 os KE 1024x768 800x600 37 879 60 317 40 000 i38 800x600 46 875 75 000 49 500 1024x768 48 363 60 004 65 000 1024x768 56 476 70 089 75 000 1 0 1024x768 60 023 75 029 78 750 1 When you use this resolution set ON for 720 x 400 Mode in the OSD On Screen Display System Settings Pin Assignments and Signal Names for Analog RGB A Signal Name de Signal Name Ne Signal Name Pin Location 1 Analog R 6 ReturnR 11 Reserved 2 AnalogG 7 ReturnG 12 DDC DATA 5 3 Analog B 8 Return B 13 H SYNC 4 Reserved 9 Reserved 14 V SYNC 4 5 Digital grounding 10 Digital grounding 15 DDC CLOCK Connector Connector set screw Mini Dsub 15 pin male Inch type 4 40UNC RGB cable manufactured by Pro face FP CV02 45 lt 4 5m gt 5 If a cab e other than the specified RGB cable is used product performance cannot be guaranteed due to the possibility of noise interferi m DVI D Interface ng with the FP unit s operation Input sign
19. neider Electric M xico S A de C V Av Ejercito Nacional No 904 Col Palmas Polanco 11560 M xico D F 55 5804 5000 www schneider electric com mx AVERTISSEMENT Ce produit peut vous exposer des agents chimiques y compris plomb et compos s de plomb identifi s par l tat de Californie comme pouvant causer le cancer et des malformations cong nitales ou autres troubles de l appareil reproducteur Pour de plus amples informations pri re de consulter www P65Warnings ca gov Toutes les marques commerciales sont la propri t de Schneider Electric SE ses filiales et compagnies affili es Schneider Electric Canada Inc 5985 McLaughlin Road Mississauga ON L5R 1B8 Canada 800 565 6699 www schneider electric ca 2018 Schneider Electric All Rights Reserved Reservados todos los derechos Tous droits r serv s Schneider
20. rom burning out when the touch panel is not used for some period of time With this parameter you can set the time interval to turn off the screen display how much time passes before the screen display is turned off when the touch panel is not used If the touch panel is not touched over the set time the backlight will automatically turns off Select the time period from 1 min 3 min 5 min 10 min and OFF Auto OFF function disabled gt BL Alarm Enables disables the Backlight burnout detect function Default ON When a burned out backlight is detected the status LED flashes alternately green and red or a steady orange Touch operation will be disabled when the backlight burns out which prevents the FP from sending input signals to the PLC IMPORTANT Normally the FP unit detects a backlight burnout b monitoring the packlight s current fow however the FP may fail to detect this condition depending on the type of backlight problem I Detect 2 Point Touch Enables to halt the data output procedure when two points of the touch panel are pressed Default OFF lt Disable gt IMPORTANT When doing the touch operation on a screen like the desktop of Windows disable this function Depending on the conditions it may not be able to be detected that the two points were pressed gt Power on Buzzer Enables disables the buzzer sound in turning the power Default ON lt Buzzer sounds enabled gt 55 USB Touc
21. splays Touching the icon you want to adjust displays its submenu or setting change screen In the setting change screen icons are used to change the setting To apply the setting press the pe art Press the button to save the defined settings m Quitting the OSD To quit the OSD press the En or button in the top menu or leave the OSD as it is for at least 30 seconds 13 MEAN Inthe OSD pressing the button applies the set value and enables the setting The set value won t be canceled unless the power is turned OFF or the value is reset If the power is turned OFF without saving the set value that data will disappear The last saved data will be read into the system when the FP starts To enable the changed value be sure to press the SAVE button All the setting values even though in process of the OSD settings will be retained in condition of letting the OSD leave more than 30 seconds or by pressing the button The OSD will keep those values and make them effective until power off or a Reset command input Em Top Main of Color Settings GB 5 ity Selection of the change item an s gt Contrast Koa gt R Contrast L G Contrast B Contrast Brightness _ Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu 7 Screen Settings gt Selection of the change item gt H Position Analog RGB only gt V Position Analog
22. upply cable When the FG terminal is connected be sure the wire is grounded Not grounding the FP unit will result in excessive noise Use your country s applicable standard for grounding m Power Cord Specifications Use copper conductors only Power Cord 0 75 to 2 5mm Diameter 18 to 12 AWG Conductor Simple or Stranded Type Wire 10mm 0 39in Conductor Length If the Conductor s end individual wires are not twisted correctly the end wires may either short against each other or against an electrode m Wiring When connecting the power cord use the following items when performing wiring Items are made by Phoenix Contact Recommended Dri SZS 0 6x3 5 1205053 river Al 0 75 10GY 3201288 Al 1 10RD 3200182 Al 1 5 10BK 3200195 Al 2 5 12BU 3200962 Recommended Pin Terminals Recommended CRIMPFOX ZA3 Pin Terminal 1201882 Crimp Tool 11 e Accompanying AC type power supply connector is CA7 ACCNL 01 from Pro face or FKC2 5 3 STF 5 08 is manufactured by Phoenix Contact E Connecting the Power Cord 1 Confirm that the power is not sup plied to the FP unit 2 Push the Opening button with a small and flat screw driver to open the desired pin hole 3 Insert each pin terminal into its each hole Release the Opening button to clamp the pin in place Opening Button AC power supply cord S L A ON RE a D
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 プロジェクターヘルパーの使い方 パーソナルコンピューター md300cf3 operator ma.. 29 Machine à café automatique «Caffè Caruso - Migros Les chartes d`utilisation de l`Internet dans le contexte éducatif Moodle User Manual for Instructors Origin Storage 500GB TLC SATA 2.5" Embedded SDK (Software Development Kit) Operating instructions Samsung Samsung C3520 User Manual Copyright © All rights reserved.