Home
( 4 in 1) USER MANUAL LED BAR
Contents
1. Safety Instructions WARNING Please read theseinstructions carefully which includes important information aboutthe installation usage and maintenance of this product The following symbols are used to identify important safety information on the product and inthis manual AA AAA DANGER DANGER WARNING WARNING WARNING Safety hazard Hazardous Fire hazard LED light Refer to user Risk of severe Voltage Riskof emission Risk injury or death lethal or severe of eye injury electric shock This light belongsto grade protection device therefore the light mustconnect to the earth excellently And the power connection mustbe operated bythe professional technician Make sure thatthe working voltage will not higheror lower thanthe rated value Make sure thatthe cable didn tbe damage orlacerated by sharp The light mustbe power off when it s standing idle orbefore clearing The cable mustwith plug andyou must pullout the cable by handle the plug Please be careful when installing the lighting Never touchthe bared cable or it will causethe deadly electricshock Please use the suitable and safe cable to connectthe light Please never remodelthe light randomly we will not take the guarantee for the faulty and damage which caused bydismantle repair or remodel of the nonprofessional person Maximum ambient temperature 40 C Do notoperate fixture attemperatures higher than this Never connect the device to adimmer pack
2. 3 PINTO 5PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin2 Pin2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use 4 OPERATING INSTRUCTIONS Control Panel Functions MODE ENTER UP DOWN BUTTON FUNCTION Exits from thecurrent menu orfunction Enables the currently displayed menu or sets the currently selected value in tothe selected function Navigates upwards through the menu list and increases the numeric value when ina function Navigates downwards through the menu list and decreases the numeric value when ina function Menu Map MAIN SUB FUNCTION FUNCTION SELECTION INSTRUCTION dMX doo 001 512 Set DMX startaddress RODO 6000 2 m aaa User can combineRED GREEN BLUE Colo booo o and WHITE togenerate a customcolor wood 5000 00 20 Select strobe frequency ATOO 01 50 SP00 20 auto programs available AUTO APOD 01 50 SP00 20 combine auto program CPOO 01 25 combine cartoon effects MAIN SUB FUNCTION FUNCTION SELECTION INSTRUCTION SLAN SLA Slaves 11CH 04CH 06CH 15CH Select 11 04 06 15 17 21 60 channel PERS 17cH Setting 21CH 60CH OF means select linear dimming or GET OFF choose dimmer 1 4to control thedimming diM speed dimming 1of the fastestdimming DIM1 2 3 4 curves 4 forthe most slowlydimming curve NER 1 00 Version number KEY ON OFF _ Enabl
3. Do not daisy chain power to more than 8units 120Vand 12 units 230V 2 INTRODUCTION Specifications Voltage Rating AC100V 240V 50 60Hz Power Rating 110W LED Quantity 15X4 in 1 RGBW LED 380mA Beam Angle 20 30 40 option Ingress Protection IP65 indoor option Product Size 990X120X145mm Package Size 1070X160X170 mm N W 5 7Kg Features RGBW color mixing with or without DMX controller special effect minimum 16psc onegroup 5 distinct dimming curves LED display with password protection Transfer custom programs between fixtures Operating Modes DMX512 Connection Master amp Slave DMX Channels 11 04 06 15 17 21 60 channels Product Overview DMX IN LED SIGNAL DMX OUT POWER IN INDOOR POWER OUT H power IN OUTDOOR E DMX OUT POOWER OUT LED SIGNAL a DMX OUT Dimensions 3 SETUP Installation Requirement This product can be used ina variety of situations can hang and put on the ground If hanging the fixture for over head use then please followthe below steps Please choose thesuitable location toput or hangthe light wheninstalling it You must use the exclusive clamp hanger and screw when hanging it and make sure the weight of the lig
4. switch settings on the controller Check cable connections Call service technician Note In the event of Display PCB failure areplacement PCB can be ordered directly from Ourcompany Loss of signal Use only DMX cables Install terminator Note Keep DMXcables separated frompower cables orblack lights COLOR CON Controller does not function or does not function properly Stand alone operation Make sure connectoris firmly connectedto device This fixture mustbe in the correct mode inorder to properly respond to the COLOR CON controller The correctmode is DMX in the onboard Control Panel This fixture has built in automatic programsthat may be triggered from theonboard Control Board The display is only showing The password lockouthas been enabled you can usethe password MODE UP MODE DOWN MODE UP MODE DOWN
5. 1 is forselecting the dimmer mode and dimmer speed When channel 11 is notactivated then RGBWand Master Dimmer are linear The dimmer modes 1 2 3 and 4 are different speeds of thenonlinear dimming curves 21 channels Channel Value Description LED 1 000 015 No Function LED 2 016 031 R LED 3 032 047 G LED 4 048 063 B LED5 064 079 R G LED6 080 095 G B LED 7 096 111 R B LED8 112 127 R G B LED9 128 143 Ww LED 10 144 159 R W LED 11 160 175 G W LED 12 176 191 B W 13 LED 13 192 207 R G W 14 LED 14 208 223 G B W 15 LED 15 224 239 R B W 240 255 R G B W 16 Module 1 17 Module 2 18 Module3 006 255 strobe 0 20HZ 19 Module 1 fade 000 255 DIMMER SPEED 20 Module 2 fade 000 255 DIMMER SPEED 21 Module 3 fade 000 255 DIMMER SPEED 000 005 No Function Att Module 1 iscomposed of 1 5LED Module 2 iscomposed of 6 10LED Module 3is composedof 11 15 LED 60 channels Channel Value Description LED1 000 255 RED 0 100 LED1 000 255 GREEN 0 100 LED1 000 255 BLUE 0 100 LED1 000 255 WHITE 0 100 LED2 000 255 RED 0 100 LED15 000 255 RED 0 100 58 LED15 000 255 GREEN 0 100 59 LED15 000 255 BLUE 0 100 60 LED15 000 255 WHITE 0 100 Master Slave Control Mode 1 Setting master machine Access control panel function by pressing MODE until AUTo is displayed Press ENTER select ATODI APODO CPOO by p
6. 15 channels Channel LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 LED 8 LED 9 LED 10 LED 11 LED 12 LED 13 LED 14 LED 15 Value 000 015 Description No Function 016 031 R 032 047 G 048 063 B 064 079 R G 080 095 G B 096 111 R B 112 127 R G B 128 143 Ww 144 159 R W 160 175 G W 176 191 B W 192 207 R G W 208 223 G B W 224 239 R B W 240 255 R G B W 17 channels Channel LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 LED 8 LED 9 LED 10 LED 11 LED 12 13 LED 13 14 LED 14 15 LED 15 Value 000 015 Description No Function 016 031 R 032 047 G 048 063 B 064 079 R G 080 095 G B 096 111 R B 112 127 R G B 128 143 Ww 144 159 R W 160 175 G W 176 191 B W 192 207 R G W 208 223 G B W 224 239 R B W 240 255 R G B W 16 strobe 000 255 strobe 0 20HZ 17 FADE 000 255 Dimmer speed fast toslow 11 channels Channel Value Description 1 Dimming 000 255 0 100 2 RED 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 white 000 255 0 100 6 Macro color 000 009 No Function control 010 255 Macro color control 7 Strobe 000 255 Strobe 00 20Hz 000 004 1 ON 2 ON
7. 3 ON 005 034 1 ON 035 064 2 ON 065 094 3 ON 8 Module 095 124 1 ON 2 ON Selection 125 154 1 ON 3 ON 155 184 2 ON 3 ON 185 214 1 ON 2 ON 3 ON 215 244 1 OFF 2 OFF 3 OFF 245 255 Convert to 11CH 2 000 005 No Function 006 025 AUTO AT01 50 10 000 255 Auto speed 11 000 255 Dimmer speed 9 AUTO MASTER DIMMER Channels 1 controls the intensity ofthe currently projected color When the slideris at the highest position 255 then the intensity of the outputis at themaximum RED GREEN BLUE AND WHITECOLOR SELECTION Channels 2 3 4and 5 controlthe intensity ratioof each ofthe Red Green Blue amp white LEDs 1 2 3 4 and 5channel can beused in combinationr COLOR MACROS Channel 6 selects the required Color Macro Channel 6 has priority over Channels 2 3 4 amp 5 Channel 1 isused to control the intensity ofthe current Color Macro STROBE Channel 7 controlsthe strobe of Channels 1 through6 Channel 7 has priority over Channels 2 3 4 58 6 Speed of thestrobe is adjustable from 0 to 20 Hz MODULE SELECTION Channel 8 providesindividual control ofthe three LED modules in each fixture 245 255 switchto the 11CH 2 mode AUTO PROGRAMS Chanel 9 selectsthe presetAuto programs 1 50 When activating the Auto programs then it is possible to control the auto speed by using Channels 10 Channel 9 has priority over channels 2 8 DIMMER SPEED Channel 1
8. Access control panelfunction by pressing MODE until AUTO is displayed Press ENTER select AT AP or CP by pressing UP DOWN buttons Setting slave machine Access control panelfunction by pressingMODE until SLAV is displayed Press ENTER GROUP WORKING DMX512 MODE 11CH 2 Channel Value 000 015 Description No Function 016 031 R 032 047 G 048 063 B 064 079 R G 080 095 G B 096 111 1 Module 1 112 127 R B R G B 2 Module 2 128 143 W 3 Module 3 144 159 160 175 R W G W 176 191 B W 192 207 208 223 R G W G B W 224 239 R B W 240 255 000 005 R G B W No Function 006 255 strobe 0 20HZ 000 005 006 255 No Function combine auto program AP 1 50 000 009 No Function 010 255 000 255 combine cartoon effects CP 1 25 No Function 000 244 Convert to 11CH 1 8 Mode selection 245 255 000 005 Convert to 11CH 2 No Function 006 255 AUTO AT 1 50 000 255 000 255 CH5 6 9 auto speed Dimmer speed AUTO PROGRAMS Chanel 5 selects the preset combine auto program AP 1 50 Chanel 6 selects the preset combine cartoon effects CP 1 25 Chanel 9 selects the presetAuto program AT 1 50 When activating the Auto programs then it is possible to controlthe auto speed by using Channels 10 Channel 9 has priority over channels 2 8 Channel 5 haspriori
9. LED BAR 4 in 1 USER MANUAL s gt 1 a 2 8 1 BEFORE YOU BEGIN What isincluded 1 x Fixture 1 x Powercable with plug 1 x UserManua Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the cartonand all packing materials In the event that a fixture mustbe returned tothe factory it isimportant that the fixture be returned in the originalfactory box andpacking AC POWER This fixture hasan auto switching switch mode power supply thatcan accommodate a wide range of inputvoltages The only thing necessary to do before powering onthe unit isto make surethe line voltage you are applyingis within the rangeof accepted voltages This fixture will accommodate between 100V and 240VAC 50 60 Hz Each lightis connected endto end bythe power socket POWER IN and POWER OUT on the light or use the waterproof power cord Please ensurethe head andthe tail tighteningwhen connect the lights to prevent the powerleakage occurred bywater seepage tothe plug Help preserve the environment Ensure thatthis product is recycled at the end of itslife Your supplier can give details of local arrangements for the disposalof products
10. es or Disables password lockout C SUM 01 16 amount set of combined lights Cid 01 16 number set ofcombined lights CoMP Operating instructions 1 Enable password lock KEY ONJ OFF ENTER ON enable lock OFF disable lock Enable the password lock control panelin the bootor go into standby automatically take effect this time to operate lamps needto enter your password MODE UP MODE DOWN MODE UP MODE DOWN ENTER DMX512 ControllerMode 1 Setting DMX512 Address dMX 001 512 Access control panelfunction by pressing MODE until dMx is displayed Press ENTER addor reduce channels by pressing UP DOWN between 001 and512 Press MODE toexit 3 Setting Channels PERS 11CH 04CH 06CH 15 CH 17 CH 21CH 60 CH Access control panelfunction by prekssing MODE until PERS is displayed Press ENTER button select DMX channel by pressing UP DOWN Press MODE toexit DMX512 Channel Values 4 channels Channel Value Description 1 000 255 Red 000 255 Green 2 3 000 255 Blue 4 000 255 White 6 channels Channel Value Description 1 000 255 Red 000 255 Green 2 3 000 255 Blue 4 000 255 White 000 005 No Function 5 006 255 strobe auto speed 000 005 No Function 6 006 255 AUTO AT01 50 Channel 6 haspriority over channels 1 5 When activating the Auto programs then it is possible to controlthe auto speed by using Channels 5
11. ht is within limits of the hanger Please make sure without any flammable objects within 0 5m when installing the light The installation should be operated by professional person any irregular installation will cause the body injury or equipment damage Block access belowthe work areaand use suitable and stable platform when installing or servicing fixture Safety Cable Note the cablemust be i secured through the heat Hanging Clamp sink ventilation Note sold passagewa separately gewoy Connection of DMX Signal Wire Please use the fixture controller wire specially when use the DMX512 Controller Connectthe male 3pin connector side of the DMX cable to the output female 3 pinconnector of the first fixture Connect the endof the cable coming fromthe first fixture which willhave a male 3pin connector tothe input connectorof the next fixture consisting of a female 3 pin connector Then proceed to connect from the output asstated above tothe input ofthe following fixture and so on This product can be connected numerous lamps in series without the need forthe signal amplifier the signal will not be weakened 3 PIN TO 5 PIN CONVERSION CHART Note If you use a controller with a 5 pin DMX output connector you will need to usea 5 pinto 3 pinadapter 2 DMX
12. ressing UP DOWN buttons Press ENTER andthen press MODE to exit Youcan choose ATOO pre set programs therange is o1 50 Or you canchoose APOD custom programs therange is o1 50 2 Setting slave machine Access control panel function by pressing MODE until SLAY is displayed Press ENTER GROUP WORKING o N wo ENANOS ENS SS gt 6023069009000 0 0 4 4 Po oo og0oo gt ooo gt go OOO OF Poo 90005 9000o0Ol 60 gogo ooo 93 Eras arar oo IEA EILINEN Fo SS SS SoS aS e Se Sas SS SS SS SS SS oo osos po oo ogoooo OOOO OD Soo So gogo oJ ooo g900o 900003 Po oo g9gy0oooo yo OO OD E JA 1 Amount set ofcombined lights Access control panelfunction by pressing MODE until COMP is displayed Press ENTER select C SUM by pressing UP DOWN buttons Press ENTER Amount set ofcombined lights by pressing UP DOWN between01 and 16 Press MODE toexit 2 Number set ofcombined lights Access control panelfunction by pressing MODE until COMP is displayed Press ENTER select C ID by pressing UP DOWN buttons Press ENTER Amount set ofcombined lights by pressing UP DOWN between01 and 16 Press MODE toexit Att the numberof the lightcould not biggerthan the amountof the combinedlights 3 Setting master machine
13. ty over channels 2 6 Channel 6 haspriority over channels 2 4 5 APPENDIX Service Maintenance Guide Symptom s Possible Solution s Clean the fixture regularly to avoidany such failure This fixture is convection cooled which means that ifthe surface iskept clean 1 or moreLED s are and free ofdebris then propercooling will be allowed to occur not illuminating An LED may have failed resultingin an opencircuit In this event all of thered green orblue in asingle module willno longer illuminate This does not meanthat all ofthe LEDs have failed but the circuitis wired inseries An LED mayhave failed resultingin a shortcircuit In thisevent only the single LEDwhich has failedwill no longerfunction This does not mean that allof the LEDshave failed butthe circuit iswired in series Note In the event of LED failure a replacementLED PCB assembly may bepurchased directly from Our company Symptom s Breaker Fuse keeps blowing Possible Solution s Check total load placed on the electrical circuit Check for ashort in the electrical wiring internal and or external Device has nopower Check for poweron Mains Note In the event of autoswitchingtransformer failure the unit can be sentin for repair however areplacement part canbe ordered directly from Our company Fixture is not responding to DMX Check Control Panelsettings for correctaddressing Check DMX cables Check polarity
Download Pdf Manuals