Home
User Manual
Contents
1. 2 and switch 3 is on and the left are off as above DMX address Value 2 4 6 Switch 1 Off 0 Switch 4 of 0 Swesor 9 Swin on oo Swen of 9 Swes Of 9 seno of 9 3 Multi fog machines connection Three pin instruction PIN1 GND ground PIN2 COLD negative pole PIN3 HOT positive pole 4 Multi fog machines connection method DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain 3 PY S242071 connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors DMX IN DMX OUTPUT DMX IN DMX OUTPUT DMX OUTPUT NO 1 Notes When it is not controlled by the controller only one fog machine can be set as MASTER with the other fog machines set as SLAVES All of blue LED indicators of Slaves will be on off regularly Connect the controller with the fog machines with 3 pin DMX signal cable and the DMX address of SLAVES ranging from 001 511 should be set uniformly The fog machine is distributed with one channel and channel value decides fog machine s output B Master Mode 1 Setting Master mode When
2. the 10 switch is off it is Master mode In Master mode fog machine is controlled either by a Z 6 controller box or a wireless receiver and transmitter 5Pin Connector for the z6 controller box orWireless receiver z 6 Controller Box Wireless Receiver 2 Wireless Receiver and Transmitter PY S242071 Button 1 4 on the wireless receiver corresponds to Button 1 4 on the wireless transmitter s The transmitter can control four fog machines with different DMX address Select the corresponding address in order to receive signal by setting the corresponding switch On Receiver Transmitter The using method as follows x Set different address for 4 fog machines Switch 1 4 correspond to different address Switch On means the address is set while Switch Off means the address is not set You can set the Switch as you need Example 1 For the Receiver x Switch 1 on the first fog machine is set On x Switch 2 on the second fog machine is set On x Switch3 on the third fog machine is set On 2 Switch4 on the fourth fog machine is set On For the Transmitter Press Buttoni on the transmitter to control the first fog machine and by analogy Button2 to control the second fog machine Button3 to control the third fog machine and Button4 to control the fourth fog machine Example2 For the Receiver x Switch 1 on the first fog machine is set On 25 Switch 1 on the second fog machine is set On x Switch1 on
3. the third fog machine is set On x Switch1 on the fourth fog machine is set On For the Transmitter Press Button1 on the transmitter to control all the fog machines PY S242071 3 Z 6 Controller Box Indicator 1 Red control indicator When Z6 controller box is connected to the mains power correctly the red indicator will light on 2 Yellow timer indicator Press Button Timer and the indicator lights on 3 Green heating indicator When the fog machine is being heat green LED indicator will light off When it is heat up green LED indicator will stay on When it is over heat green LED indicator will be on off regularly XTX e e Using Method For the Fog Output Volume Press MANUAL and the fog machine reaches the max output Release MANUAL button press CONTROL and adjust the fog output volume by rotating VALUE knob Or press TIMER button the yellow LED indicator will light on to let the fog machine work in fixed time Then rotate INTERVAL knob to adjust fixed the time up Notes In Master Slave Only one fog machine can be set as MASTER with the other fog machines set as DMX That is the other fog machines should be set to DMX Mode Set the DMX address correctly Connect all fog machines with 3 pin DMX signal cable The Master and the Slaves run in sync C Max Output Function In DMX mode or in Master Slave mode the max output function should always have the priority Trough manual adjustment of the fog volu
4. User Manual VPF 1500 Table of contents INTTOGUELOR dE Safety Informatio od ee re Panel ReVIeW dado ee ae rer OPERA Os Mess Aa a A ey te a a ei DMX MOC scare E der de e uda ud Master Mode ice n nee Max Output FUNGON soo oie San eco oes etu a ee ie OU eia e Indicators Instruction HII Techiniealsspecitle dile edu urs t emen cde chance ie tel ads PY S242071 INTRODUCTION Thanks for purchasing VPF 1500 Please read this manual carefully and thoroughly as it gives important information regarding safety and operation instruction Keep this manual in order to consult it in the future The quality of every set of the products is guaranteed in the factory before the shipment Please check the accessories as the packing list inside If the carton appears to be damaged please inspect the fixture carefuly In case damage has been found or some parts are missing please contact the after service department before shipping back the product Packing list Power cord User manual Maintenance card Wireless receiver Wireless transmitter Controller box VPF 1500 fog machine Tank SAFETY INFORMATION Always make sure that you are connecting to the proper voltage see parameters chart and the voltage can be allowed to fluctuate 10 Ground the power cord Use the professional fog oil otherwise it will affect fog machine s performance and sh
5. e green indicator on the Z6 controller box as well as green indicator above the dipswitches will flash TECHNICAL SPECIFICATION Model VPF 1500 fog machine Input voltage AC 110V 60Hz or 230V 50Hz Fuse 15 125V 10A 250V Power 1500W Dimension L530XW239XH215mm Weight 15kg PY S242071 PY S242071 10
6. me in DMX mode or through Z6 controller box max fog volume will be achieved The following operation will enable the max fog volume 1 Press 1 4 button on the wireless transmitter to enable PY S242071 2 Press MANUAL button on the Z 6 controller box to enable 3 Press green MANUAL button on the panel to enable D Indicators Instruction Blue DMX Indicator When fog machine is in Slave mode and receives the valid DMX signal the LED indicator will light on otherwise it turns off Fog Oil Indicator When the tank has no oil two red LED indicators will flash and two green indicators will light off When the tank has oil the two green LED indicators will stay on and the two red LED indicators will light off See the fog oil indicators position in the following picture e S lt S o Fog Aperture Temperature Indicators When oil is being heat the red indicator at the side of the tank will light on while green indicator at the side of the tank the green indicator on the Z6 controller box as well as green indicator above the dipswitches will light off When oil is heat up the red indicator at the sde of the tank will light off while green indicator at the side of the tank the green indicator on the Z6 controller box as well as green indicator above the dipswitches will light on When oil is over heat the red indicator at the side of the tank will light off while green indicator at the side of the tank th
7. orten its lifespan Put the fog machine in well ventilated place For indoor use only and do not use it in a humid and drenched place Do not heat fog oil and always keep it in normal ambient temperature PY S242071 Do not dilute oil with water or other liquids Unedible fog oil No drinking Do not put your hands close to aperture of the fog machine Keep the machine out of the children s reach Far away from flammable and explosive materials in case of hurt Put the fog machine on the ground or solid work areas instead of hanging on the shelf Keep at least 60 centimeters distance from people when fraying Nornc professionals should not dismantle fog machine in case of electrical shock or scald Do not change inner components and fixtures PANEL REVIEW PY S242071 o Oo O1 8 D gt Manual switch Temperature indicator Dipswitches DMX in DMX out Controller box output or wireless receiver output Switch on off Power socket Interval Timer Control Manual Value Notes 9 13 buttons are on the controller box OPERATION PY S242071 a E ei al a o A DMX Mode 1 Setting DMX mode When Switch10 is ON the system enters into DMX mode and DMX address can be set through Switch 1 9 Off On 1 2 3 45 6 7 8 9 10 2 Caculating DMX address a Qo Off O nn OD i 3 6 T B 9 10 PETER a For example If switch
Download Pdf Manuals
Related Search
Related Contents
Télécharger - Ville de Saint StarTech.com 6 ft DisplayPort to DVI Cable - M/M TEX1000 - 3 3D Network Blu-ray Disc™/ Lettore DVD Samsung SMART Camera NX Mini & 9 mm objektiv (svart) Käyttöopas Whirlpool UXT4030AAB User's Manual 14-15 Bulletin d`infos Châbles-Cheyres _v1 REPUBLIK ÖSTERREICH Copyright © All rights reserved.