Home
CV1800 and CVMAX Owner`s Manual
Contents
1. Clear Vue DA Cyclones CV1800 and CVMAX Owner s Manual Shown with 30 gallon collection drum not included and optional Clean Out Box Clear Vue i 4 Cyciones 145 Nix Road Liberty SC 29657 1 888 299 0221 www ClearVueCyclones com Disclaimer WARNING All persons by purchasing a motorized dust collection system motor or individual parts from CLEAR VUE CYCLONES or using these instructions which are provided as suggestions only agree to the following disclaimer Installing and or operating this motorized dust collection system or use of individual parts involves the risk of serious bodily injury or even death The buyer and user accept total responsibility for any and all operation or use that may lead to personal injury economic loss social distress other losses costs and damages Seller is not responsible for injuries and or damages of any kind resulting from operating this motorized dust collection system motor or use of individual parts or instructions All Rights Reserved June 2013 Duplication of any part of this manual without the expressed written permission from Bushey Enterprises Inc is prohibited IMPORTANT Minimum Recommended Ceiling Height A minimum floor to ceiling height of approximately 8 feet 96 inches is required The content of this manual is based upon the assembly of a CV 1800 cyclone under an 8 ceiling If your ceiling is lower than this recommended height please contact us to di
2. Cut a hole in the center of the lid about 1 2 smaller than the 6 flex house supplied with the cyclone The easiest way to do this is to draw a 3 radius 6 diameter circle centered on the top using a fine point marker Draw a 2 3 4 radius 5 Y diameter circle inside of it Cut on the inside line using snips jig saw or other appropriate tool b Using pliers bend a 4 lip up all the way around until you are able to screw the hose into the lid c Caulk the hose from both sides of the lid to seal it in place d Install a rubber weather strip approx 2 thick x 1 wide to the underside of the lip where it contacts the trash can This will provide a seal e Option For further reinforcement bungee cords may be stretched across the lid on either side of the flex hose and attached to the ends of the handles 2 Attach the lid to the cyclone a Place the 6 flex hose clamp over the top of the flex hose Make sure it is loose b Install the lid by placing the 6 flex hose over the base of the cyclone c Tighten 6 flex hose clamp to secure flex hose to the base of the cyclone To ensure an airtight seal caulk around the top of the flex hose la amp 1b 1c 1d 21 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 13 Wire Motor Clear Vue Cyclones recommends that you have a professional licensed electrician complete wiring on any electrical work Our Leeson Motor requires a 30 amp bre
3. Vue Cyclones 2013 Step 2 Build and Mount Wall Bracket Note Aluminum Hanging Brackets are available for purchase at www ClearVueCyclones com Instructions for installing Aluminum Hanging Brackets at located at the end of this document 1 Cut the L Bracket components CV1800 CVMAX 2 vertical members from 2 x 4 lumber 9 2 long 9 2 long 2 horizontal members from 2 x 4 lumber 18 long 20 long 1 Bracket back from 4 plywood 12 x 26 12 x 26 2 bracket sides from plywood 91 x 19 Y 9 x 21 2 Join the vertical and horizontal members a Using two 12 x 2 4 or longer screws join the vertical shorter members to the horizontal longer members by driving the screws through the vertical member into the end grain of the horizontal member 3 Attach the sides to the bracket a Glue the bracket sides to the L bracket Reinforce with 10 1 2 screws 4 Mount L brackets to the wall a The top of the bracket back should be at least 8 96 or more above the floor b Ifyou are using a collection bin that is higher than 28 you will need to increase the height of your L brackets accordingly c Attach the bracket back to the wall by driving at least 8 or more screws through the bracket into the wall studs Important These screws will be holding the weight of the entire unit so 12 x 3 or longer screws are recommended d Attach the assembled
4. and 2 Insert capscrews through drilled holes in bushing flange thread loosely into tapped holes in bushing flange and thread loosely into tapped holes in sheave hub 3 Position assembly on shaft and tighten capscrews 3 Position assembly on shaft and tighten capscrews progressively and uniformly progressively and uniformly TO REMOVE TO REMOVE 1 Remove capscrews and thread into tapped holes in 1 Remove capscrews and thread into tapped holes in sheave hub Tighten progressively until bushing is free bushing flange Tighten progressively until bushing is from sheave taper free from sheave taper 2 Remove assembly from shaft 2 Remove assembly from shaft CAPSCREWS ARE ALWAYS ACCESSIBLE FROM THE OUTSIDE QD BUSHINGS PROPER WRENCH TORQUE DRY MOUNTING DO NOT USE LUBRICANTS OR ANTI SEIZE COMPOUNDS ON TAPERED BORE OR BUSHING SUITCASE TIGHTENING IMPORTANT Tighten screws evenly and progressively Never allow the sheave to be drawn in contact with the flange of the bushing If extreme screw tightening forces are applied excess pressures will be created in the hub of the mounted sheave which may cause it to crack TEZENN SESERS SET SCREW TIGHTENING TORQUES ANO AXIAL LOADS RECOMMENDED SET SCREW AXIAL LOAD 230 SET SCREW SOCKET ALLEN KEY TIGHTNING TORQUE CUP POINT KNURLED POINT Note For adal loads in excess of the values listed a shouldered shaft agains the face of the inner ring 18 recommended 25 CV1800
5. bracket sides to the mounted bracket back using 12 x 2 4 screws The tops and outside edges of the components should align 3 x 4 1 2 8 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 3 Construct Motor Impeller Assembly 1 Attach threaded rod to motor plate a Set up 4 threaded rods with the items shown The box in yellow indicates items that will be set up later Set these aside for now Leave about 2 to 2 2 between item groups b The washer on the top of the shock mount should be approximately 4 high Leave the jam nuts loose They will be tightened later c Insert 4 threaded rod through each hole of the MDF motor plate d Thread rod into T nuts until they almost bottom out Important The T nuts are installed on the rabbet side which is facing down in the picture Make sure the T nuts are on the bottom side before inserting the threaded rod from the top Group 1 Order Flat Washer Lock Washer and Nut is Oo Group 2 Order Nut Nut Flat Washer Grommet Flat Washer 1b 1c la 2 Install the motor mount plate a Slide the motor mount plate onto the threaded rods Important The strips on the motor mount plate should be facing toward the ceiling during assembly and when mounted on the hanging brackets 3 Install the hanging bracket upper shock mounts a Slide the grouping from the yellow box onto the top of the threaded rod above the hanging bracket Ti
6. 013 Step 9 Assemble Filter Assembly Flangeless Filters zh az Stack the two filters together Run a bead of silicone caulk around the outside joint where the two filters meet Place a washer on the 4 20 x 1 hex bolt Wrap the band clamp around the joint Insert the bolt through the hole on the band clamp and tighten Place another 4 20 x 1 washer a 1 4 lock washer and a 1 4 20 wing nut on the hex bolt and tighten te a 200000009000 VOC 158 O P CONN SII E ONO 3 5 1 Finished product 18 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 10 Install Clean Out Box If you did not purchase our clean out box you may build your own The only requirement is that the box be airtight when closed and have an opening to remove residual dust from filters To build your clean out box 1 Determine the height of your clean out box a Place the filter assembly under the transition b Measure the distance from the top of the filters to the bottom of the transition The distance will be the overall height of the clean out box 2 Box suggestions and recommendations a The box can be made from plywood or MDF b It should be 14 x 14 x height measured in step 1 c Leave an access opening in the front of the box and build a gasketed cover plate F Example of box Example of cover plate To install your clean out box 1 Place the filter stac
7. Owner s Manual Clear Vue Cyclones 2013 26 PROPER WRENCH TORQUE TO TIGHTEN SCREWS OPEN END OR SOCKET WRENCH TORQUE TORQUE WRENCH LENGTH Ft Lbs Inches PULL LBS CV1800 Owner s Manual Clear Vue Cyclones 2013 Addendum Installing Aluminum Hanging Brackets Installing Aluminum Hanging Brackets 1 Assemble hanging brackets a Take 1 short leg and 1 long leg of the bracket and assemble using a bolt washer and nut b Mount supporting leg to the L bracket using bolt washer and nut c Follow procedure A and B for the second L bracket 2 Measure where the brackets will be mounted on the wall and mark accordingly Note some customers choose to mount the brackets to a piece of plywood before mounting to the studs 3 Drill mounting holes in L brackets using an appropriate sized drill bit 4 Using mounting hardware not included mount L brackets to the studs of the wall Important These screws will be holding the weight of the entire unit so 12 x 3 or longer screws are recommended 96 or 8 feet minimum 27 CV1800 Owner s Manual Clear Vue Cyclones 2013 Addendum Assemble Filter Assembly Flanged Filters a 1 Remove the rubber seal from one and only one of the filters before joining them together 2 Stack the two filters together 3 Drill 2 pilot holes through the filter brackets Size holes to fit the bolts you will be using Holes can be positioned in the corners or
8. aker Motor Rotation and Wiring Instructions 1 Use the CW wiring diagram from the motor plate LT connects to Pl b L2 connects to T4 amp T8 c P3 amp Tl amp T5 wire together d The ground wire bare wire goes to a green screw inside the motor connection box This is a typical two pole single throw relay The contact should be rated for at least 30 amps and the coil voltage should be 110V This allows for the ability to switch the coil on and off with a regular light switch or a remote control that turns lights on and off Physical Wiring Diagram Neutral 110 V White Wire Black Switch Box or Remote From ACE hardware A see link below TO Y Coll Relay Contacts Va Li 2 E Po Fo Pie oe 220 Veep Fe e a Ground Bare Wire gt 22 CV1800 Owner s Manual Clear Vue Cyclones 2013 Electrical Diagram Neutral NO Y Ll L2 White Wre Black Wire 220 V Relay Coll Switch Bare Ground Wire Please note the ground wire should never be used as a current carrying conductor Rather it should be connected to the motor body as well as other metal parts of the motor in order to dissipate stray electrical currents The proper way to wire this using a 110 volt relay coil is to run a four conductor cable from the electrical panel L1 black and L2 red are hot legs Ground bare or green and Neutral white The Neutral conductor will allow
9. e enough to allow for rotation of the cyclone if the intake chute needs to be installed If the intake chute has been installed then position the cyclone and lock the 6 clips down Note the motor plate may not sit flush to the blower housing This is normal 9 Use a level to ensure that the cyclone is level Adjust the nuts up to the bushings on the motor mounting rods if necessary 10 Once the system is mounted secure the motor mount assembly to the L brackets using either 1 1 4 sheet rock screws or 1 4 20 x 1 4 bolts Pre drill holes using drill bits so the assembly does not crack 6 amp 7 3 16 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 8 Install Intake Chute lt A gt _ gt L _ _ _ __ E _ L_ gt gt I i gt gt S gt S gt E anDh Ah hO EHE_E _ _ E__ SSSSa9 9BnDBDDA7 EH EEE Rotate the cyclone if necessary so the chute is accessible Attach the chute to the cyclone using 4 6 x 3 8 long screws provided Seal the intake chute with clear silicone caulk Rotate the cyclone if necessary into position and tighten the 6 clips on the top of the blower housing oe 2 You may notice a small black grommet near the intake chute This serves to prevent dust from collecting in the dead space of your cyclone If you did not purchase filters with your CV1800 or CVMAX system please skip to Step 12 17 CV1800 Owner s Manual Clear Vue Cyclones 2
10. e larger opening of the blower housing The following are assembly instructions for the 90 transition Using a 7 16 wrench loosen the front 4 bolts on the blower housing and open it slightly Slip the transition into the blower assembly Tighten the bolts on the blower housing to clamp the transition in place When the transition is positioned drill through the 4 holes in the MDF sides using an appropriately sized bit 5 Insert a bolt and washer in each dedicated hole from the inside with the ends going to the exterior of the assembly 6 Secure the transition using a washer lock washer and nut on each bolt 7 Seal the transition to the blower using clear silicone caulk being sure to cover all seams Important Sealing the transition is very important If there are any leaks the unit will blow fine dust into your shop oo 4 5 6 14 CV1800 Owner s Manual Clear Vue Cyclones 2013 The following are assembly instructions for the straight transition 1 Using a 7 16 wrench loosen the front 4 bolts on the blower housing and open it slightly 2 Place the dedicated pieces of wood on the blower housing and tighten the bolts on the blower housing 3 Place the straight transition over the opening of the blower housing and line up the holes 4 Insert a washer and bolt from the inside with the end of the bolt going outside the blower housing 5 Secure the bolt from the exterior with a washer
11. ey using a 3 32 to 7 64 allen wrench 4 Hang motor impeller assembly a With the help of your installation partner slide the assembly onto the wall bracket The clear span in the front will have the additional MDF rail for added strength b Secure the motor impeller assembly to the wall assembly before operation of the cyclone This is best done after finishing cyclone assembly If needed move the motor impeller assembly in or out a couple of inches to make installation of the cyclone easier c Securing the assembly as well as height adjustments will be completed later If 2i 2111 4 12 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 5 Assemble Transition Begin by inserting the plastic parts in the grooves to form the transition chute Slip the transition chute into the slot of the transition bottom Drill 4 small pilot holes in the transition bottom Attach the transition chute to the transition bottom using four transition screws Apply clear silicone caulk to the exterior seams of the plastic and transition sides The caulk will go on white and dries clear It can be easily cleaned up with water oe AS 1 2 3 4 Completed Transition 13 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 6 Attach Transition to Blower Housing Important Do not remove the white piece of wood located in your blower housing This wood counters the sound as the blade passes by th
12. ghten the jam nuts so they are snug without causing the bushings to bulge Important The top nuts will be used to level the cyclone after itis hung Afterward the bottom nuts will be used to compress the bottom rubber grommets 4 Stand the motor on end Group 3 Order Flat Washer Grommet Flat Washer Nut Nut 3a 4 9 CV1800 Owner s Manual Clear Vue Cyclones 2013 5 Attach the motor to the mounting assembly a Turn the mounting assembly over and set it on the motor with the bracket holes and motor mounting holes aligned b Install 4 motor bolts 1 2 13 into the holes using a washer and lock washer on each bolt 6 Tighten each motor bolt securely Completed Motor Impeller Assembly 10 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 4 Install Motor Impeller Assembly WARNING Improper installation of your impeller can lead to the impeller coming off during use Significant damage to your system and or bodily harm can result It is imperative that you read and follow these directions closely Detailed assembly videos can be found under the Education Center Assembly Instruction section of our website at www clearvuecyclones com 1 Position the impeller a Remove the MDF shipping protector and discard It is unnecessary for installation b You will find the taperlock and screws in a small box inside of the materials box The motor key will either be included in this box or
13. k on top of the box 2 Attach the clean out box to the bottom of the filter assembly using a bead of clear silicone caulk where the filter meets the clean out box The silicone caulk will hold the filters securely in place and can be removed easily by cutting the bead with a razor knife 3 If you purchased a clean out box from our web page caulk the seams of the clean out box 4 Note If you are installing your system higher than 96 you will need to support the Clean Out Box from below Example of the clean out box available for purchase at www clearvuecyclones com 19 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 11 Filter Cleanout Assembly to Cyclone 1 Slide the filter cleanout assembly under the transition The fit should be exact 2 Attach the filter cleanout assembly to the transition a Screws Drill pilot holes in the MDF Attach the filter cleanout unit using 1 4 6 sheet metal screws b Duct Tape Use high quality HVAC silver duct tape around the seam between the filter and the transition 3 Caulk where the transition meets the filter assembly unless you used the tape Example 20 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 12 Modify and Install Trash Can These instructions show the modification and installation of a 30 gallon corrugated metal trash can A different type of container may be used however it must be air tight upon completion 1 Modify the lid a
14. lock washer and nut 6 Seal the seams with clear silicone caulk 2 3 4 15 CV1800 Owner s Manual Clear Vue Cyclones 2013 Step 7 Attach Blower Housing to Cyclone 1 Before you begin it is important to caulk the seams of your blower housing Determine the desired orientation of the blower housing and cyclone inlet chute Note the blower discharge can be rotated and positioned in any direction to suit the needs of your shop 3 Place the cyclone in a drum or bin in order to keep the unit from tipping over as the blower housing is attached If a drum or bin is not available you will need another person to assist you in the attachment 4 Option the next section of the installation manual will discuss attaching the intake chute This may be installed now or after the blower housing is attached to the cyclone In this installation manual we will be installing the intake chute after the blower housing is attached to the cyclone 5 Attach the blower housing to the top of the cyclone using 6 1 5 8 screws Be sure not to over tighten as the plastic will crack 6 In this next step remove the cyclone and place a piece of plywood on the top of the trash can Lift the cyclone blower housing into place around the impeller 7 Slip a board or series of boards under the cyclone to lift the unit until the blower house is close to the motor plate 8 Install the 6 clips on the blower housing Leave the clips loos
15. nnnnnnnnnnnnoo 14 Step 7 Attach Blower Housing to Cyclone cccc cece cece ence eee eee eee eee e nnn es 16 Stee Install intake CIU arial prep E REEE EE E 17 Step 9 Assemble Filter Assembly cc 02c0csccscsiesceaececedeacesereauesesscedanecedeucesases 18 Step 10 Install Client marine esine rre aseos orense 19 Step 11 Attach Filter Cleanout Assembly to Cyclone oooocccccccccccccccccnncnnnaoo 20 Step 12 Modify and Install Trash Cad ooooooccccccccnnnnnncnnnnnnnnccccccnn nnn n nea eses 21 Sip Las BURN Ke 0 Cae tr ets 22 Exhibit A Maska Taperlock Installation Instructions 0 c cece cece eee ee snn 25 Addendums Installing Aluminum Hanging Brackets cc cece cece cece cece cece eee e es 2 Assemble Filter Assembly Flanged Filters 0 0 cece cece eee e eee eees 28 3 CV1800 Owner s Manual Clear Vue Cyclones 2013 There are certain items that are needed for successful installation of your Clear Vue Cyclone System Below you will find a listing of those items Tools 9 16 Wrench 7 16 Wrench 3 32 Hex Key Drill Bits Drill Level 6 Foot Ladder Tape Measure Box Cutter Items to Purchase if you don t already own 30 Gallon Trashcan with Lid or other desired collection bin 1 tube DAP Alex Plus Clear Silicone Caulk Y thick by 1 wide gasket Y Sheet of 34 Plywood 8 12 x 3 1 2x4x8 20 14 screws These i
16. on the sides 4 Assemble the two filters using bolts washers lock washers and nuts Py a UNAS 1 A 0110 IO AI A d ny eee My 1 1 SOO RS OOO OOO RAE OLA UAC OOOO OOO OME OOOO OR OOOO SOA he OOOO ORE OA O 3 4 28 CV1800 Owner s Manual Clear Vue Cyclones 2013
17. scuss your unique situation and possible options Leaks In order to maximize performance of your dust collection system it will be imperative to check for leaks Leaks on the suction side of the system will reduce the CFM cubic feet per minute performance levels We recommend the sealing of all connections in your ducting and on the intake side of the cyclone Leaks in the collection bin or at the bottom of the cyclone are major problems Such leaks will cause an up flow of air through the cyclone and prevent the dust from entering into the collection bin This will affect the separation efficiency of the cyclone and more dust will advance through to your filters which may cause blockage Leaks found anywhere after the dust reaches the blower may be blown back into your shop This is a hazardous situation and these leaks should be sealed immediately 2 CV1800 Owner s Manual Clear Vue Cyclones 2013 Table of Contents Getting to Know Your Cicle 5 Step l Check Box e E PPOOO UOU Oo0 NU NU O 2P e _ e ENEE 6 Step 2 Build and Mount Wall Bracket oooooooococccccccccncnnnccnccrcnannrnnnoos 8 Step 3 Construct Motor Impeller Assembly oooooocccccccccccccccccccccra rra 9 Step 4 Install Motor Impeller Assembly 0 0 cece cece cece cece eee eeeeeeeeeeeeees 1 Step SZ Assemble Transi ari 13 Step 6 Attach Transition to Blower HOUSIN8 oooocccccccccccccncncnnnnnnnn
18. t the time of delivery and there is visible damage to the boxes please note this with the carrier 3 Open the boxes empty the contents and check for any hidden damage If anything is damaged or missing please contact our office as soon as possible by phone or email Shipped Boxes Please note if you purchased filters with your Clear Vue Cyclone system they will be shipped directly from the manufacturer Materials Box Filter Boxes Motor Box 6 CV1800 Owner s Manual Clear Vue Cyclones 2013 Cyclone Box Contents Cyclone Body Please note If you purchased blast gates with your system they will be included in this box Blast Gates sold separately Cyclone Hardware 4 3 8 x 1 2 Motor Bolts 4 3 8 Flat Washer motor 4 3 8 Lock Washer motor 8 Rubber Grommets 4 Pan Head intake chute 6 15 8 Blower Housing Screws 4 1 Transition Screws 8 x 20 Lock Washers 28 x 20 Flat Washers 24 x 20 Nuts 4 x 20 x 7 Threaded rods 4 Ya x 20 x 1 Hex bolts transition bolts 2 6 Band Clamps Materials Box Contents Viotor Mount impeller ve Blower Housing 90 Transition t ina sembied Note If there is a key taped to your motor please do not discard You will need this key as part of your installation If the key is not present it will be packed with the taperlock bushing CV1800 Owner s Manual Clear
19. taped to the motor with blue tape Do not discard the key you will need this as part of your installation c Slip on impeller onto the motor shaft d Place the taperlock on the shaft of the motor lining up the key holes of the shaft to the taperlock 1d le le e Insert the key and lightly tighten the setscrew against the key using a 3 32 to 7 64 allen wrench until 1t cannot fall out f Insert the 3 bolts included with the taperlock through the large non threaded holes on the taperlock Thread them into the three threaded holes on the impeller 2 Tighten taperlock bolts a Lift the impeller so that the taperlock is flush with the tip of the shaft Tighten the bolts one at a time around in a circle until they are all tight 1 Snug one bolt down then a second then a third As you tighten the impeller is drawn up towards the motor ii When you return to the first bolt it will be loose This is due to the other bolts having pulled the taperlock closer to the hub 11 Repeat this process until the bolts are all torqued to the specifications outlined in the Maska s Installation Instruction sheet Exhibit A pg 25 Upon completion there should be a minimum of 4 clearance between the impeller and mounting plate bolt head Note We are using a JA 11 CV1800 Owner s Manual Clear Vue Cyclones 2013 bushing with a reverse mount The torque requirement is 5 ft Ibs 3 Tighten the setscrew against the k
20. tems are not necessary if you have 8 12 x2 4 purchased the Aluminum Mounting Brackets Single Phase Systems Only Installation Time Installing your CV1800 cyclone takes approximately 4 6 hours to assemble with two people Ducting your shop tends to be more time consuming and varies based on the size of the shop design and labor 4 CV1800 Owner s Manual Clear Vue Cyclones 2013 Getting to Know Your Cyclone Motor Motor Mount bia Blower Housing _______ Impeller 90 Transition Intake Chute we Cyclone Body Filters 6 Flex Hose Clean Out Box in Collection Bin Items are not included and may be purchased separately CV1800 Footprint 24 x 53 MAX air flow through 6 pipe 1442 CFM CVMAX Footprint 24 x 53 MAX air flow through 8 pipe 1935 CFM 5 HP Leeson Motor 230 volts 1 Phase 20 8 FLA 7 8 shaft 50lbs 1 year manufacturer s warranty Wynn 9L300BL Filter 12 75 x 34 300 sq ft lock bushing wrapper transition 5 CV1800 Owner s Manual Clear Vue Cyclones 2013 Assembly Instructions Step 1 Check Box Contents 1 Prepare the site where you will be installing your cyclone If there are any space or placement issues please contact our office so that we may help resolve them before you begin unpacking your boxes 2 The cyclone components are shipped in three boxes Note If you are present a
21. you to run a 110 volt relay or other device if connected between the neutral and one of the hot legs as shown above Pre wired Electrical Box with remote available for purchase at www ClearVueCyclones com Note Once the motor 1s wired the motor shaft and impeller blade should be turning counter clockwise when viewing from below 1e looking up at the motor and impeller from the floor A rotation sticker on the blower housing points in the direction the curved part of the impeller blades should be spinning 23 CV1800 Owner s Manual Clear Vue Cyclones 2013 Option The diagram below uses a 220 to 24 volt step down transformer to power a relay with a 24 volt coil This gives the ability to use the existing wiring with the advantage of running low voltage wiring and switches around your shop L Er Ground 220 v Relay Contacts 220 v Primary Transformer 24 v Secondary 94 v Relay Coil switch 24 CV1800 Owner s Manual Clear Vue Cyclones 2013 Exhibit A Maska Taperlock Installation Instructions QD BUSHING MOUNTING AND PROPER WRENCH TORQUE STANDARD MOUNT EITHER REVERSE WAY MOUNTING BUSHING FLANGE TOWARD MACHINE OR MOTOR BUSHING FLANGE AWAY FROM MACHINE OR MOTOR 1 Align tapped holes in bushing flange with drilled holes in 1 Align drilled holes in bushing flange with tapped holes in sheave hub sheave hub 2 Insert capscrews through drilled holes in sheave hub
Download Pdf Manuals
Related Search
Related Contents
700.082G ASUS B53S User's Manual Miele UltraPhase 2 Cisco 1605R Installation guide Whirlpool Refrigerator ET1FHTXMB01 User's Manual Rosen Entertainment Systems DP-1001 GPS Receiver User Manual Typhoon TV PVR Universal Traité de savoir-vivre à l`usage des jeunes générations Copyright © All rights reserved.
Failed to retrieve file