Home

Installation Guide & User Manual

image

Contents

1. ONote The initial administrator password is 1234 Change Administrator Password 1 The administrator N 2 Press 8 You can 3 Enter a new password is authenticated _ change the password administrator password Failed Y The indicator turns red KE and makes three beeps 6 Exit Ge turns 5 Succeed The 4 Enter the new ee ano makes a long Il t indicator turns blue and administrator password eep then automatically the makes a long beep again for authentication exit ONote Four digit passwords are automatically verified For passwords with less than four digits press to enter the verification process Open the Door by Entering the Administrator Password E 2 Press 0 The 3 Press 0 The EE gt indicator turns blue and gt indicator turns blue and p makes a long beep makes a long beep 5 Exit The indicator turns red and makes a long beep then automatically exit 4 The door is opened The indicator turns blue and makes a long beep ONote This function can be used to open the door lt Administrator Password is Forgotten If the administrator password is forgotten please dismantle the device and wait 30 seconds when there is a long beep then press the Optical Tamper Switch three times to reset to the initi
2. 5 Exit The indicator turns red and makes a long beep then automatically exit i successful The indicator m turns blue and makes a 4 The configuration is long beep Configure Alarm Delay for the Door Status Sensor DSen Delay Door Sensor Delay It is to configure the time how long would the door sensor would do check the door status 1 The administrator password is authenticated 2 Press 0 The indicator turns blue and makes a long beep 3 Press 4 The indicator turns blue and makes a long beep 6 Exit The indicator turns red and makes a long beep then automatically exit 5 The configuration is successful m The indicator turns blue and makes a long beep N 4 Configure the alarm delay range 1s to 254s ONote Three digit values are automatically verified For values with less than three digits press to confirm Values greater than 254 are considered invalid 2 6 SRB Security Relay Box SRB is a relay switch to control electric lock exit button to provide higher security level for access control It is installed on a secured place and connected with standalone access control devices by Wiegand out ONote For electrical parameters and connection guide please consult SRB Simple Access Controller Connection Guide 2 7 Factory Reset 1 The administrator
3. 4 Configure the concealed mode 0 enable 1 disable Note An indicator blinks to indicate the status of this function when users are authenticating their cards or passwords 2 4 Configure Door Sensor Mode The door sensor has three modes e NONE The door sensor is disabled e NO The door sensor will send an alarm signal if it detects the door is closed e NC The door sensor will send an alarm signal if it detects the door is open 1 The administrator password is authenticated 2 Press 0 The indicator gt turns blue and makes a long beep 3 Press 5 The indicator turns blue and makes a long beep 6 Exit The indicator turns red and makes a long beep then automatically exit 5 The configuration is successful The indicator turns blue and makes a long beep 1_ sensor mode 0 Normally 4 Configure the door Open 1 Normally Closed 2 Disabled ONote The door sensor mode configured here is used as the basis for the door sensor alarm 2 5 Configure Alarm Configure Alarm Switch The alarm switch is turned on by default When it s disabled then Error Operation Triggered Alarm and the Alarm Delay for the Door Status Sensor will be disabled but Tamper Alarm still works 1 The administrator password is authenticated 2 Press 0 The indicator turns blue and makes a long
4. Installation Guide amp User Manual Standalone Metal RFID Series Version 2 1 Date January 2015 Important Note Document Privacy Note Firstly thank you for purchasing the product Before use please read this manual carefully to avoid the unnecessary damage The company reminds you that the proper user will improve the use affect and authentication speed No written consent by company any unit or individual isn t allowed to excerpt copy the content of this manual in part or in full also spread in any form Document use statement Due to the constant renewal of products the company can not undertake the actual product in consistence with the information in the document also any dispute caused by the difference between the actual technical parameters and the information in this document Please forgive any change without notice Reserve the final rights of modification and interpretation Contents Installation Guide i Equipment Installation ora aran l 2 Str ct r and FUNCOM EE Il A PR E OE EE EEE EEEE R Ea Ill 4 Connected with Other Parts i IV 5 Connect with Power IV User Manual 1 User Ee Enn TE 1 1 1 Administrator Operatons nn nnnnnnrnnnnnnn na nccnnnnn 1 12 AO USCIS aura a 2 1 3 Register Eight Passwords for Opening the Door 3 1 4 Authenticate USer iii 3 15 Delete USCIS irritante basano 4 2 Access Control Management EE 5 2 1
5. Register Cards in Batches 3 Swipe the first card once 1 The administrator 5 2 Press 6 Registering Swipe the card once password is authenticated _ Cards in Batches Failed Yes The indicator turns red and makes three beeps 6 Exit The indicator turns red 5 Cards are registered 114 Enter the total number and makes a long beep Ges in batches successfully NY of cards then automatically exit ONote 1 In the process of entering the total number of cards three digit numbers are automatically verified For numbers with less than three digits press to enter the verification process Press to reenter the total number of cards 2 IDs of to be registered cards must be consecutive numbers 1 3 Register Eight Passwords for Opening the Door This device supports 8 passwords each password has a Group ID ranges from 1 8 The default password value is O for all groups which means passwords are disabled You can modify the passwords under 8 groups to open the door 1 The administrator 2 Press 3 password is x The indicator turns blue Soa at CG SR 8 authenticated and makes a long beep H Paso E 7 Exit Press the 6 Register successfully 4 Enter the password indicator turns red and di _ twice k The indicator turns blue makes a long beep then and makes a long beep The passwor
6. ENT A UX I device output current ULock lock voltage ILock lock current 4 Connect with Other Parts lt e 5 Connect with Power oND no DC 12V Sor DC12V DC 12 Y Smoke Detector D m Leg e Input DC12V lt 110mA lt 80mA standby Positive is connected with 12V negative is connected Voltage output lt DC 12V for Alarm mi GND do EHS the polarities gt cim x oie Bell y IV Recommended procedure Step 1 Power on after the device is completely installed on the wall Step 2 Change the administrator password and configure access control parameters including unlocking duration authentication mode concealed mode door sensor mode and alarm etc Step 3 Register users cards or eight passwords 1 User Management 1 1 Administrator Operations To ensure data security of the device you can operate the device only after the administrator password is authenticated Authenticate the Administrator Password 1 Press 2 Press 3 Enter the administrator The indicator is off and m gt You can authenticate gt password The initial makes a long beep the password password is 1234 Yes 5 Exit Press or do not operate the device within 20 seconds The indicator turns red and makes a long beep then automatically exit 4 The authentication is successful The indicator turns blue
7. password is authenticated 2 Press 0 The indicator turns blue and makes a 3 Press 9 The indicator turns blue and makes a beep then automatically exit The indicator turns blue and makes a long beep long beep long beep 6 Exit The indicator turns 5 The configuration is red and makes a long 1 successful 4 Press 9 a short beep The Factory Default Settings 3 Switch Working Mode This device could work as a standalone controller or as a wiegand reader which offers flexibility to use depending on actual needs It is a standalone controller by default setting but you could switch the working mode by the following instruction If the indicator blinks blue indicates that the device is set to Controller Mode If the indicator stays in red indicates that the device is set to Reader Mode ONote For wiring diagram of reader mode please consult Appendix 3 1 Controller Mode Switch to Reader Mode 1 The administrator password is authenticated 2 Press 0 The indicator turns blue and makes a long beep long beep 3 Press 6 The indicator m gt turns blue and makes a red and makes a long beep then automatically exit 6 Exit The indicator turns 5 Set mode successfully The indicator turns blue and makes a long beep 4 Press 1 K Th
8. Configure Unlocking Duration miei 5 2 2 Configure Authentication Mode ciororoiiniamninta ir 5 2 3 Configure Concealed Mode cuco rare 6 2 4 Configure Door Sensor Mode AAA 6 2 5 COMIQUIS Alina is 7 ad Sip IO E ee ere en meee ee tT etree rarer errr 8 2 7 Factory E 9 3 Switch Working Mod ui 9 3 1 Controller Mode Switch to Reader Mode Akne 9 3 2 Reader Mode Switch to Controller Mode 10 APP ira 11 Packing adas 11 lt e 1 Equipment Installation Fix the back cover on the wall Exposed wire I Remove the screw on the bottom of device Fix the device to the back cover Take away the back cover i Please pick off the plastic when TI wire G Ba 2 Structure and Function Access Control System Function 1 If a registered user is verified the device will send a signal to unlock the door 2 Door Sensor will detect the door is open or not If the door is unexpectedly opened or improperly closed the alarm will be triggered 3 It supports Exit Button it is convenient to open the door inside 4 It supports Smoke Detector etc it will alarm and open the door when receives the signal of detector 5 It supports Door Bell visitors could call by the door bell 6 If the device is dismantled it will send an alarm signal O Linkage Function This device has an Auxiliary Input interface AUX which allows it to be connected with an ext
9. al administrator password each press shall take 2 5 seconds and it comes a beep each time note this operation must be done within 30 seconds It is successfully reset when it has a long beep after the third press the Red LED blinks and quits the operation by itself ONote The initial administrator password is 1234 1 2 Add Users Register the card of a user or register cards in batches d Add Users 4 Register cards Swipe the card once 1 The administrator 2 Press 1 password is E The indicator turns blue authenticated and makes a long beep SODA The indicator turns blue EN 4 Register cards and makes a long beep Swipe the card once 6 Exit Press the indicator 5 Adding users successfully turns red and makes a long The indicator turns blue and beep then automatically exit makes a long beep Note 1 Nine digit user ID is automatically verified For user ID with less than nine digit press to confirm 2 If the user ID is not available the ID number increases automatically It continues to register new one once a user is successfully registered 3 The registration fails if the user ID or the card has been registered the indicator turns 2 red and makes three short beeps When the indicator turns blue you can register the user again If you fail in swiping card or entering user ID three times the device will enter the standby state
10. and makes a long beep ONote 1 You can swipe the card or input user ID to delete a user Nine digit user ID is automatically verified For user ID with less than nine digit press to confirm 2 The device automatically enters the process of deleting the next user when a user is deleted or press to exit Delete All Users 1 The administrator password is authenticated 2 Press 9 The indicator turns blue and makes a long beep 3 Press 9 The indicator turns blue and makes a long beep ONote Press 9 for automatic confirmation Other values are considered invalid If an 5 Exit The indicator turns red and makes a long beep then automatically exit 4 Deleting All Users is __ successful The indicator turns blue and makes a long beep invalid value is entered the device indicator turns red and the device makes a long beep and exits the process 2 Access Control Management 2 1 Configure Unlocking Duration 1 The administrator password is authenticated 2 Press 4 The indicator turns blue and makes a long beep 3 Enter the unlocking duration range 1s to 254s 5 Exit The indicator turns red and makes a long beep then automatically exit 4 The unlocking duration is modified The indicator turns blue and mak
11. beep 3 Press 1 The indicator turns blue and makes a long beep 6 Exit The indicator turns red and makes a long beep then automatically exit 5 The configuration is successful The indicator turns blue and makes a long beep 4 Configure the alarm setting 0 enable 1 disable Configure Error Operation Triggered Alarm Alarms will be generated if the administrator fails the authentication upon three attempts under this function enabled and it is not allowed to continue within 20 seconds 1 The administrator password is authenticated m 2 Press 0 The indicator turns blue and makes a long beep 3 Press 2 The indicator turns blue and makes a long beep 6 Exit The indicator turns red and makes a long beep then automatically exit 5 The configuration is _ successful m The indicator turns blue and makes a long beep _ operation triggered 7 alarm switch 0 enable 4 Configure the error 1 disable Configure Tamper Alarm If this function is enabled alarms will be generated when device is dismantled from the wall 1 The administrator password is authenticated 2 Press 7 The indicator turns blue and makes a long beep 3 Configure whether to enable the tamper alarm 0 enable 1 disable
12. d consists of automatically exit four digits ONote If a password is successfully changed enter the Group ID to change next one 1 4 Authenticate User Card Password Authentication After the device is powered on it enters the authentication state for unlocking the door 1 The device is in the 2 Swipe the card or enter the password Press e 3 The authentication is L N successful The indicator lt o authentication state Y after entering the turns blue and makes a password long beep Failed The indicator turns red and makes two short beeps ONote Press after entering a password for authentication The door opens if the entered password is identical with one of the eight passwords for opening the door 1 5 Delete Users Delete a user whose card is registered or delete all users lt Delete a User 1 The administrator 2 Press 2 The indicator 3 Swipe the user card or turns blue and makes a input user ID once which password is authenticated long beep io be deleted Failed The indicator turns red Yes and makes three beeps 6 Exit Press or do not operate the device within 20 5 The user is deleted See aun GR seconds the indicator turns The indicator turns blue red and makes a long beep then automatically exit and makes a long beep indicator turns blue
13. e indicator turns blue and makes a long beep ONote The device makes three short beeps when fails in setting then the indicator turns red and makes a long beep then automatically exit 9 Set Weigand Format When the device is in Reader Mode hold and press five seconds press when the red indicator turns off then input administrator password to enter the device lt can be set to Weigand 26 or Weigand 34 1 The administrator password is authenticated 2 Press 0 The indicator turns blue and makes a long beep 3 Press 7 The indicator turns blue and makes a long beep 6 Exit The indicator turns red and makes a long beep then automatically exit 5 Set format successfully The indicator turns blue and makes a long beep lt 4 Set Weigand format 0 WG26 1 WG34 ONote The device makes three short beeps when fails in setting then the indicator turns red and makes a long beep then automatically exit 3 2 Reader Mode Switch to Controller Mode When the device is in Reader Mode hold and press five seconds press when the red indicator turns off then input administrator password to enter the device 1 The administrator password is authenticated 2 Press 0 The indicator H gt turns blue and makes a long beep 3 Press 6 The indicator turns blue and makes a 6 Exit The indicator
14. ernal source for instance a smoke detector gas detector infrared sensor or emergency switch Trigger Linkage Once detectors or sensors are connected to AUX and are triggered the system receives the linkage signal and would generate an alarm and open the door the door keeps open and alarm keeps on until the linkage is canceled Cancel Linkage The linkage can be canceled when a user is verified or the Administrator opens the door with password lt e 3 Lock Connection A Warning No operation when power on 1 The system supports NO LOCK and NC LOCK For example the NO LOCK normally open by power on is connected with NO terminal and the NC LOCK is connected with NC terminal 2 When the Electrical Lock is connected to the Access Control System you need to parallel one FR107 diode equipped in the package to prevent the self inductance EMF affecting the system do not reverse the polarities 1 Share power with the lock O ULOCK 12V IDevice ILock The maximum operating current of device is 100mA and the rated current is 60mA And the lock is near to the device DC12V NO Lock II Does not share power with the lock Device does not share power with the lock O Utock 12V lt IDevice ILock The maximum operating current of device is 100mA and the rated current is 60mA ULock 12V The lock is far from the device DC12V DC12V NC Lock 4 4 y a DC12V NO Lock Frane Ch Kat DC12V
15. es a long beep ONote The unit of Unlocking Duration is second Three digit values are automatically verified For values with less than three digits press to enter the verification process 2 2 Configure Authentication Mode 1 The administrator password is authenticated 2 Press 5 The indicator turns blue and makes a long beep 3 Enter the authentication mode 5 Exit The indicator turns red and makes a long beep then automatically exit successful The indicator 4 The configuration is turns blue and makes a long beep ONote 1 When the authentication mode is RF amp password swipe card and then enter the passwords please 2 Details about the authentication modes are as follows Authentication Mode PW RF RF PW default 2 3 Configure Concealed Mode If the Concealed Mode is enabled the indicator is off Only password verification Only RF Card verification RF or password verification RF and password verification 1 The administrator password is authenticated PT 2 Press 0 The indicator turns blue and makes a long beep 3 Press 3 The indicator turns blue and makes a long beep 6 Exit The indicator turns red and makes a long beep then automatically exit 5 The configuration is successful The indicator turns blue and makes a long beep
16. turns red and makes a long beep then automatically exit 5 Set mode successfully The indicator turns blue and makes a long beep if long beep SS 4 Press 0 The indicator turns blue and makes a long beep ONote The device makes three short beeps when fails in setting then the indicator turns red and makes a long beep then automatically exit 10 Appendix Wiring Diagram of Controller Mode Red DC 12V Light Blue SEN Black GND Gray BUT Yellow NC Purple BELL Bell Pink COM Brown BELL Bell Blue NO Weigand Output Linkage Function Green WDO Orange AL Alarm White WD1 Light Green AUX Packing List 0 O o gt alclalolols SEH Access Device 8 1 Card Mounting Plate Y W 1 Star shaped Screw 1 Installation Guide 4 Screws 4 Wall Plugs Wiring Diagram of Reader Mode Red DC 12V Black GND Green WDO White WD1 Gray BEEP Light Blue LED Purple BELL Bell Brown BELL Bell 600 4 Diodes FR107 Screwdriver

Download Pdf Manuals

image

Related Search

Related Contents

  第3編 再発防止に向けて GPSをより有効に利用するために 1 GPSの  NB 011-04_Rev2 folheto de Instruções Eletronico Notebbok I43.cdr  Explosionsgeschützte Kettenzüge Zone 1, II 2 G - STAHL  IPM3300 Multi-Function Power Meter User guide  Bayonet 2の取扱説明書はこちら  User Manual - UniqueSquared.com  Cables Direct 6m Cat5e  APPENDIX A  Samsung 204B Felhasználói kézikönyv  