Home

MINUTEMAN - PowerCenter for Linux User`s Manual

image

Contents

1. MINUTEMAN PowerCenter for Linux User s Manual Copyright 2005 Para Systems Inc Document Version 1 3 Attention root authority is required for rpm and upsm commands NOTE This UPS daemon does not save open documents The Options saved_file and auto_save on off pertain only to the UPS data log Install Red Hat compatible system Command rpm ivh PowerCenter_Linux 1 0 3 1 i386 rom Description The UPS daemon will automatically startup after installation and every time the system boots up You can use upsm command to control and monitor this UPS daemon Other Linux systems Command tar zxvf PowerCenter_Linux 1 0 3 1 tar gz cd PowerCenter_Linux 1 0 3 install sh Description Command tar will extract the compressed file into a folder name PowerCenter_Linux 1 0 3 enter this folder then type install sh The UPS daemon will automatically startup after installation and every time the system boots up Uninstall Red Hat compatible system Command rpm e PowerCenter_Linux 1 0 3 1 Description This command will uninstall the UPS daemon Other Linux systems Command uninstall sh Description This command will uninstall the UPS daemon Operation Command upsm status information log configure test help Description The upsm command allows users to monitor and control the UPS Command upsm help options Description Displays all detailed instructions under each option The options include stat
2. s section can be configured Options auto_save on off Enable or disable the auto save function for the UPS data log port dev Set communication port value of dev should be one of upsm information port list shutdown on off Enable or disable shutdown function when power fails shutdown_delay hour minute second Set shutdown delay time the value of seconds must be assigned the values of hour and minute are optional after power fails poweroff_delay hour minute second Set delay time the value of seconds must be assigned the values of hour and minute are optional before UPS powers off Command upsm test options Description Performs a UPS self test If you do not specify the options the UPS will perform a self test within 10 seconds Options t sec Indicates testing time in seconds value of sec c Cancels the current UPS test
3. us information log configure test help Command upsm status options Description Displays current UPS status If you do not specify which option the status information of each option will be shown Options utility_state Displays the utility condition normal fail charger_state Displays the output condition discharging charging bypass battery_state Displays the battery condition normal critical low Command upsm information options Description Displays the UPS service device information and configuration If you do not specify which option all items will be shown All exhibited data appears with mark to signify the current setting Options port Displays all configurable communication ports and the current setting shutdown Displays the current setting of the shutdown function on off shutdown_delay Displays the values of delay seconds before the UPS shuts down your computer and auto save the log files poweroff_delay Displays the values of the delay seconds before the UPS powers off Command upsm log options Description Displays or erases with e the UPS data log specified by options Options e Erase log listing event Displays the Event log saved _file Displays the auto saved Log files status Displays the Status record Command upsm configure options Description Allows the user to configure UPS services and unit Only the items shown in the upsm information option

Download Pdf Manuals

image

Related Search

Related Contents

User`s Manual - PLANET Technology Corporation.    Manual PDF  取扱説明書 - アルケア  Philips Softone Lustre  取扱説明書 - 日産自動車  Vosstronics Primus Elegans  Nokia 2128i Cell Phone User Manual  TC522-528.indd - Scandic Tools  Collection Bibliothèque – Lab`AU Pajol  

Copyright © All rights reserved.
Failed to retrieve file