PBR-310C EBERT Operation Manual

image

Contents

1. Y introduction CHI Data Time Error Count bit Bit Error Rate Actual Time 7 252000 10 0 000000 0 2013 3 19 FF 04 7 751000 0 0 000000E 0 8 250000 0 0 000000E 0 8 750000 0 0 000000F 0 9 247000 0 0 000000E 0 9 750000 lo 0 000000E 0 CH2 Data Time Error Count bit Bit Error Rate Actual Time 000000 o 0 000000E 0 0 206000 0 0 000000E 0 0 706000 0 0 000000E 0 1200000 0 0 000000 0 1706000 o 0 000000 0 2 206000 0 0 000000 0 2 706000 0 0 000000E 0 3 203000 0 0 000000E 0 3 609000 0 0 000000E 0 MAIWAN f A A Ammannin X P gt n Figure 13 Error BER information Table Item Description the no of checking interval over the measuring period Error Count Accumulation no of error from start test to current state Bit Error Rate Accumulation BER from start test to current state Actual Time Indicate the corresponding date and time on your PC Table 4 BER Information history 22 Innovative Transmission Tech hytrex SERIAL E BERT B Observe the Eye Diagram EyeTrex Here are some quick tips to guide the user quickly access the EyeTrex mode to observe the Eye Diagram of DUT E P m 2 v Setting BER History Eye Irex Timer 0 Rate 10 3125 Pattren Channel 1 PRBS31 Channel 2 PRBS31 1 Dee EyeTrex Eye Monitor 5 gt 3 2 gt
2. UL IEC Safety This product is UL and cUL Listed to the requirements of Standard 61010 1 Second Edition Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements FDA IEC Laser Safety The E BERT is classified by the manufacturer as a Class 1 Laser product under the requirements set by FDA CDRH 21 CFR 1040 10 and IEC 60825 2 CE Mark This product has been tested for compliance with the applicable Harmonized Standards under the European Commission EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC including amendments to both Directives Modification of a certified product The modification of a laser product previously certified under Sec 1010 2 by any person engaged in the business of manufacturing assembling or modifying laser products shall be construed as manufacturing under the act if the modification affects any aspect of the product s performance or intended function s for which this section and Sec 1040 11 have an applicable requirement The manufacturer who performs such modification shall re certify and re identify the product in accordance with the provisions of Title 21 Sections 1010 2 and 1010 3 40 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Software License Agreement Phytrex Corp Phytrex agrees to license to you Licensee Phytrex s Software provided with the PBR 310 upon the terms and
3. File Clicking this button pops up a dialog window including the save load system configuration and prompts the user to enter the name of a file under specified directory Innovative Transmission Tech Phytrex SERIAL E BERT Use extension to make the file readable by Microsoft Notepad Save to database is completion of each measuring time error count and error ratio results are appended to database the and it was readable through Microsoft Access If an existing filename 15 used results will be appended to the end of that file The file has 8 columns viz date time gating time seconds gating time BER gating time errors gating time Opening the file while the E BERT PBR 310 GUI is recording data could stop GUI operation or corrupt data To use the file while the GUI is running copy the file into another name or directory If the measuring time is set to its default value of 1 the GUI will not prompt for a file name or record data Error Detect EyeTrex Bit Error Test Start Measuring Time s 10 Criteria Stop Measure Mode BER Threshol E 8 singe Check Interval s 0 5 EXIT Figure 11 Bit Error Test Mode left Error detect setting criteria right PBR 310 has an intelligent pattern synchronization algorithm and typically does not require the user to use this button The PBR 310 may display a high error rate for 1 or 2 seconds when this button 1
4. Setup S ps Single 5 1 Figure 18 9 953Gb s PRBS31 30 Mask Margin Setting BER History Timer CHI Error Detect EyeTrex Eye Monttor mV 5 mV EXIT Figure 19 10 3125Gb s PRBS31 30 Mask Margin EyeTrex 26 PHY TRESS Phytrex SERIAL E BERT Setting BER History EyeTrex x Tuner CHI CH 0 10 518 Channel 1 PRBS31 Channel 2 PRBS31 Error Detect EyeTrex Eye Monitor Get Eye ps div mV Setup Single EXIT Figure 20 10 518Gb s PRBS31 30 Mask Margin Setting BER History EyeTrex x Tme CHI CH2 0 Bit Rate 10 7 Pattren Channel 1 Error Detect EyeTrex Eye Monitor Get Eye Gai Figure 21 10 709Gb s PRBS31 30 Mask Margin Setting BER History EyeTrex Error Detect EyeTrex Eye Monitor Gb s 2 8 mV DS EXIT Figure 22 11 1Gb s PRBS31 30 Mask Margin 21 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT gt Eye Diagram Measuring Flow Chart Launch the GUI Stop Acquisition Select EyeTrex Mode Loading Data Set Pattern Set PPG ON OFF Export test data etup Eye Diagram Parameter Mask Test Eye Contour Parameter Setup Page Press OK Button Set Acquisition Mode Sing Repeat Get Eye Start Acquisition Figure 23 Basic Eye Diagram testing procedure 28 Innovativ
5. su 4 gt singe Figure 14 Operation sequence to observe the eye diagram Switch to the EyeTrex Mode from left side menu Switch to Eye diagram test screen Setting the measuring items eye diagram parameters Setting single repeat mode for waveform acquisition the measuring result will be clear and reset when it start an new acquisition Start the waveform acquisition gt Setting Items Here 1s the setting items under the EyeTrex mode I Eye Diagram measurement parameters Amplitude P P Jitter RMS Jitter Rising Time 20 80 Falling Time 20 80 Data Rate Eye SNR I Eye Mask Test 23 Innovative Transmission Tech Phytrex SERIAL E BERT Standard Mask Selection Ethernet OGbE WAN o 9 953Gb s lOGbE WAN e 9 953Gb s lOGbE LAN 0 10 3125Gb s lOGbE LAN e 10 3125Gb s SONET SDH STM64 OC 192 9 953Gb s FEC1066 10 664Gb s FEC1071 10 709Gb s Infiniband Fiber Channel 8GFC 8 5Gb s OGFC 10 3125Gb s 10 11 096 HI Mask Margin Positive 0 10090 O default IV Histogram Vertical Horizontal Axis ON OFF V Contour ON OFF gt Waveform Parameter Mask Test and Contour Measurement Setup x File Edit Operate Tools Window Help T 9 le D J 4 n LO J Eye Contour oki D PBR310 10G BERT Masks Eye Diagram Test Parameters Standard Eye Mask Margin 0 100 Figure 15 Eye Diagram Parameters Setu
6. 1 2 1 2 patterns NRZ data signal that can be output to the electrical or Optical from the front panel The pattern generator also outputs the 1 64 data rate clock and trigger signal to facilitate observing the data signal using an sampling oscilloscope or communication analyzer The generator has LEDs indicating the power status of the system Analyzer The electrical or optical signal to be tested for bit errors 1s provided to the PBR 310 via the 500 SMA connector Unlike most commercial bit error rate testers the analyzer does not require externally clock signals Power Input Requirement AC power input requirement is 100 240 V AC 50 60Hz Innovative Transmission Tech Phytrex SERIAL E BERT A CAUTION Supplying power exceeding the above range may result in electrical shock fire failure or malfunction Front Panel Figure 2 Front Panel Overview Definition 1 Channel Pattern Generator Differential Data Output 2 Channel 2 Pattern Generator Differential Data Output 3 Channel 1 Error Checker Differential Data Input 4 Channel2 Error Checker Differential Data Input 5 Channel 1 Scope Differential Data Input 6 Channel2 Scope Differential Data Input Rear Panel Rec Clock Clock 4 K IClock 9 ie gen In A W 2 e IClock Clock In Out 7 110 240 50 60Hz Figure 3 Rear Panel Overview Innovative T
7. 2 2 The software installation process is same as single type introduced at beginning of this chapter Figure 30 Four Channel PBR 310C system Users can set the polarity of testing pattern on output or input side by clicking the Pattern Invert bottom Figure 31 Multiple PBR 310C connection 22 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT gt lt Hollo Phytrex_dual_0625 vi File Edit Operate Tools Window Help 1 4 hale esie tting BER History EyeTrex Cha x Time Data Rate Test Value 233 963 Bit Rate 10G Ethernet 103125Gbps Measuring Time 300 103125 Bit Rate 10 3125 Gbps Sync Criteria off Pattren 2 BER Threshol Recover Clock IES 31 a a Check Interval 5 4 05 31 7 PRBS31 Chanel PRBS31 Check Pattern gt PRBS3I Check Pattern gt x Check Pattern Pattern Invert gt ERSE Check Pattern CHI CH2 w a 4 CH3 Measure Mode CH4 Pattern Invert Figure 33 Four Channel Mode Operation GUI 33 Innovative Transmission Tech Phytrex SERIAL E BERT Timer on Bit Rate 8533 0 Pattren Channel 1 PRBS31 Channel A PRBS31 Channel 3 PRBS31 Channel 4 Error Detect EyeTrex Single Figure 34 Four Eye Diagram Measureme
8. conditions of this license 1 DEFINITIONS a GUI means Phytrex s E BERT GUI b Software means GUI and any and all other software and firmware provided with Phytrex s hardware copies of such software provided electronically or on disks or other media user documentation packaging and any enhancements modifications updates bug fixes releases patents patent rights copyrights trade secrets know how and other intellectual property related thereto c Derivative Works means any revision modification product specific application abridgement condensation expansion collection agglomeration or other form in which the Software may be recast transformed or adapted d Designated System means any computer hardware or operating system designated on Purchase Order s resulting from the MOU 2 GRANT OF LICENSE Phytrex hereby grants to Licensee a perpetual non sub licensable non exclusive license the License to internally use reproduce and create Derivative Works of the Software or portions thereof for internal business purposes only and not on behalf of any third party Phytrex reserves the right to exploit the Software and or any Derivative Works commercially or to license others to make use or sell the same for any purpose commercial or otherwise Licensee shall not a remove any product identification copyright notices or other notices or proprietary restrictions from the Software b transfer sell as
9. interface An USB Virtual COM serial communication interface is provided through an USB connector jack on the front panel Use the USB cable provided with the System to connect the unit to the desktop or laptop PC There is no hardware flow control provided on the PBR 310 s serial interface The USB COM port settings are shown in Chapter 2 No other special serial port settings such as FIFO buffer sizes are required on the computer PC running the E BERT GUI Figure 4 USB Connector on rear panel BEER ESA MAMA AW EEH gH css 4 2 user PC gt Bluetooth gt DVD CD ROM gt lt lt IDE ATA ATAPI 288 b Jungo gt da AMEN BRE gt lt gt EREHE gt iil ERE gt 4 9 422 8 28 COM A LPT hu USB Serial FO UN A nagp BG pU ps 238 gt BEB gt p 2 gt i Figure 5 Virtual COM display on Device Manger in Windows Control Panel 11 Innovative Transmission Tech Phytrex SERIAL E BERT Chapter 2 System Installation Introduction This chapter provides information necessary for the proper installation of the PBR 310 Hardware installation The PBR 310C package has the following items Mainframe a chassis DC to 18GHz Broadband Terminator USB Jack to Jack cable for Serial interface to PC terminal AC power cable grounded M Software in
10. relief nor will such termination relieve Licensee s obligation to pay all fees that have accrued or are otherwise owed by Licensee under any Order Form The parties rights and obligations pursuant to Sections 2 3 4 5 6 7 10 11 and 14 and all other provisions that by their terms or nature are intended to survive shall survive any termination of this Agreement 9 EXPORT The Software is subject to United States export control laws and may be subject to export or import regulation in other countries Licensee agrees to comply with all such regulations and acknowledges it has the responsibility to obtain any licenses as may be required to export the Software 10 VERIFICATION At Phytrex s written request Licensee shall furnish Phytrex with a signed certification verifying that the Software 15 being used pursuant to the provisions of this Agreement and applicable invoices Phytrex may audit Licensee s use of the Software Any such audit must be conducted during regular business hours at Licensee s facilities and shall not unreasonably interfere with Licensee s business activities Audits may be conducted no more than once per quarter 11 GOVERNING LAW ARBITRATION This Agreement shall be governed by the laws of the State of California U S A without reference to conflict of laws principles or statutory rules of arbitration disputes arising out of this Agreement shall be settled by binding arbitration in Sunnyvale California under the Comm
11. 3 3 PBRS31 4 User Edit Timer The period of Error Detect time unit sec ED on off set true to start Error Detect But _EDPatternInvert set true to invert the electrical signal that ED receive error in Check number that indicate whether the sub viis Work normal Output Result VISA resource out COM Port release for next sub vi error out Check number that indicate whether the sub vi is work normal DAPBR31OXLabviewAPBR310 lIbXPATCHK 0403 vi error out VISA resource in cad set 1 But EDPatternInvert error in error out Set error checker Start or Stop Set your error check Pattern not include User Edit Pattern Channel string 1 2 Pattern string PRBS PRBSS PRBS23 PRBS31 ED on off string on off Description Start or Stop error detecting Set the pattern for pattern checker 4 1 5 Get Pattern Check Result Input Variable VISA resource in COM Port connecting to PBR305 channel ch1 channel 1 ch2 channel 2 set Datarate 8 5 11 2 Gbps Timer The period of Error Detect time unit sec 37 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT error in Check number that Indicate whether the sub viis work normal Output Result VISA resource out COM Port release for next sub vi Result Total Bits Detector check bit count Error Count error count Detector has detected Timer the time last to finish test BER Bit Error Rate Status Not Synch
12. 5 clicked Measuring Mode Setting testing mode into Single or Repeat The measurement modes are defined below 1 REPEAT mode Unit measurement is repeated continuously during the set gating time measuring time 2 SINGLE mode Unit measurement is performed once during the set gating time Start Stop When pressing the Start it clears the previous testing result and begin the new testing event with respective gating time error count and BER until pressing the Stop 19 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Folder BER Measurement Result CHI CH2 Error Count 0 Error Count 0 Timer 55 5702 BitErrorRate 060 Bit Error Rate 00 Figure 12 Bit Error information for Channel 1 and Channel 2 Time Indicates the time that has elapsed within the current gating interval Error Count Indicates the number of bit errors in the previously elapsed second This display 1s refreshed every half second Bit Error Rate Displays the BER graphical up to the last elapsed second within the current gating interval The graphical display plots the gating time BER versus time in half second unit The scrollbar allows viewing the BER over 24 hours Drag and hold the scroll button along the scroll bar at the desired location Once the scroll button is released the graph scrolls forward automatically to display the latest BER result Status Indicate the pattern checker status there are sev
13. OPERTY RIGHTS AND ANY OTHER THIRD PARTY CLAIMS OF ANY KIND ARISING FROM THE SOFTWARE OR DERIVATIVE WORKS 8 TERMINATION If not otherwise specified on the Order Form this Agreement and each license granted under this Agreement will continue perpetually unless terminated under this Section 7 THIS LICENSE SHALL AUTOMATICALLY TERMINATE WITHOUT NOTICE TO LICENSEE if Licensee a transfers sells assigns sublicenses or otherwise conveys the Software to another party or b causes or permits reverse engineering disassembly or decompilation of the Software Upon termination however caused Licensee shall return all copies of the Software to Phytrex and shall certify in writing that all components of the Software have been returned made unreadable or erased from the memory of Licensee s computers Either party may terminate this Agreement in the event the other party 1 terminates or suspends its business 11 becomes subject to any bankruptcy or insolvency proceeding under federal or state statute or iii becomes insolvent or becomes subject to direct control by a trustee receiver or similar authority In addition either party hereto or may terminate this Agreement at any time by giving written notice to the other party at least sixty 60 days prior to the effective date of the termination set forth in the notice Termination of this Agreement or any license will not limit either party from pursuing other remedies available to it including injunctive
14. PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT PBR 31 0C E BEHT User Guide All rights reserved PHYTRESS PBR 310 Copyright 2014 Phytrex Technology Corp All rights reserved Statement of Conditions Phytrex Corp reserves the right to revise the information in this document without notice Phytrex Corp provides this documentation without warranty of any kind either implied or expressed including but not limited to the implied warranties of merchantability and fitness for a particular purpose Phytrex Technology Corp reserves the right to make changes or improvements in the products and or the services described in this documentation at any time If there is any software on removable media described in this documentation it 15 furnished under a license agreement included with the product as a separate document or in the hard copy documentation Version 2 3 2014 03 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Contents CSAS Sale PISI E E E sa 3 SYA SPEC ICATONS 5 eerte oett aeter aor 6 Handling Precautions 6 Chapter 1 System OvervIew 7 Chapter 2 System Installation 12 Chapter 3 E BERT Graphical User Interface GUI 16 Chapter 4 E BERT Labview Programming Guide 20 C
15. Phytrex and Licensee shall cooperate in any legal process concerning alleged infringement of any third party s alleged rights arising from Phytrex s or Licensee s use of the Software Phytrex shall have sole control over any litigation with respect to indemnifiable Losses hereunder and any settlement thereof 6 LIMITATIONS OF PHYTREX S OBLIGATIONS Any modification or attempted modification of the Software by Licensee or any failure by Licensee to implement improvements and updates to the Software as supplied by Phytrex shall void the obligations of Phytrex under this License terminate this License and entitle Phytrex to seek appropriate legal remedies unless License has obtained prior written authorization from Phytrex permitting such modification attempted modifications or failure to implement 7 LIMITATIONS ON LIABILITY UNDER NO CIRCUMSTANCES AND UNDER NO LEGAL THEORY TORT CONTRACT OR OTHERWISE SHALL PHYTREX BE LIABLE TO LICENSEE OR ANY OTHER PERSON FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY CHARACTER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF GOOD WILL WORK STOPPAGE COMPUTER FAILURE OR MALFUNCTION OR ANY AND ALL OTHER COMMERCIAL DAMAGES OR LOSSES EVEN IF PHYTREX SHALL HAVE BEEN INFORMED OF THE POSSIBILITY THEREOF THIS 41 Innovative Transmission Tech Phytrex SERIAL E BERT ARTICLE STATES THE ENTIRE LIABILITY OF THE PARTIES TO EACH OTHER WITH RESPECT TO INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PR
16. Time Engine and the PBR 310 GUI To Install the NI Run Time Engine and the PBR 310 GUI on the PC connected to the PBR 310 place the Software installation disk in the CD drive Double click the SETUP file The installer will automatically install the NI Run Time and PBR 310 GUI Windows XP S2K3 Vista 7 BED EO KAO BOREU IAW HAM O ss i AbD GREEAKLIF C9 CUM ES ane EE C3 PBR310 O umen 4 888 Lass 14 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Destination Directory Select the primary installation directory All software will be installed in the following locations To install software into a different locations click the Browse button and select another directory Directory for PER310 C Program FileaPBR 310A Directory for National Instruments products D Program Files Wational Instrumente Figure 8 Installing the PBR 310 GUI and NI Run Time PHITRE Running the PBR 310 GUI Launch the PBR 310 Graphical User Interface by double clicking on the PBR 310 icon Click the arrow at the top left hand corner of the screen to operate the PBR 310 l Windows NT and Windows XP are trademarks of Microsoft Corp LabVIEW is a trademark of National Instruments Corporation 15 PHYTRE amp s Innovative Transmission Tech Phytrex SERIAL E BERT Chapter 3 Graphical User Interface GUI Introduction The GUI prese
17. e Transmission Tech Phytrex SERIAL E BERT Clock Recovery option 08 PBR 310 embedded the clock recovery circuit the recovery clock can be output from the rear panel Figure 24 Rec Clock Note The recovery clock is 1 64 of input data rate 3 110 240 750 60 2 Figure 24 Clock Recovery Output 1 64 Procedure 1 Press Setting Folder 2 Press The recover clock pull down menu 3 Select the recovery channel Channel 1 or Channel 2 Setting History EyeTrex Channel 1 clock divided by 64 han Channel 2 clock divided by 64 Figure 25 Clock Recovery Setup Screen 29 Innovative Transmission Tech Phytrex SERIAL E BERT e XM SE PAO NAN ey M Weer wt be ous ede pod 1 2842 Norm Delay 25 6262 ns 2 mv Figure 27 Recovery Clock Output Waveform 10 3Gb s Re drive Data Output option 07 PBR 310C provides re drive data out from data input on error detector side Figure 24 This function can support the data output range from 8 5 11 1Gb s with 3 tap equalizer to pre compensate the channel loss on the media e g PCB or Fiber cable etc 30 PHYTREES Innovative Transmission Tech Phytrex SERIAL E BERT 31 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT B Four Channel Mode option 02 PBR 310 GUI can support multiple system 2 sets via two USB cables Figure 29 and run the software ver
18. e are provided with the installation disk Installing USB Driver Gs Windows XP S2K3 Vista 7 HA FW KAN AN Qia 2 we Gum Im AED 3 DAPhyrextBREEEHLAPER310 Windows XP S2K3 Vis 7 DES VCP Win EP Sees Vis ReleaseNote GEREARLIF ES s x E AME _ tibia tam Acres Software Inc aaa 9 EB C9 EXT gt EDS eR IRL US ASAE E PBR310 ABE KAEN TE Nurs Figure 6 USB COM Driver installation Folder 1 Power on your computer and make sure that the USB port is enabled and working properly 2 During installation please don t link USB Serial cable with your computer 3 Double click CP210x VCP Win XP S2K3 Vista 7 exe then it will start installation Figure 3 After installation click Plug in the USB Serial cable into the USB port 6 You can to check the Device Manager and see the Silicon Labs Dual CP210x USB to UART Bridge Standard Enhanced COM Port oe 13 PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT C ATAS See BRED ATO RAD NAM 5 a DVDICD ROM 368218 IDE 1255 88 SCSI amp RAID 12 588 Abs mes Y HES 299 MAR BRS de 523925 SFA PE PRES ERA Y 364218 COM fU LPT 11 44 i tt itt le lt o HE dier uno 39 gt RH 2 Fb o tti idm Emi lb le Figure 7 Check the COM port from Device manager Installing the Run
19. e data rate 1s changed or the Analyzer signal is interrupted PBR 310 records the results of bit error rate measurements in a spreadsheet format for analysis and archiving No programming knowledge 15 required to enable the recording feature PBR 310 E BERT Features The PBR 310 is a versatile unit possessing a wide variety of features summarized below B Allin one BERTS and Eye Diagram Analysis B Bit Error Ratio BER measurement for NRZ PRBS 2 1 2421 2 1 B Multi rate operation covering from 8 5 11 3Gb s function is support from 8 5 11 1Gb s Full Duplex Dual Differential 100 Q SMA electrical interface to double the testing throughput Built in clock recovery function from 8 5 1 1 3Gb s with 1 64 rate clock output Accumulated error count and error ratio statistics Graphical display of BER and Error Count Eye Diagram and Mask Test Histogram and Contour User programming library for sequential control Measurement result export option PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Physical features Y MM WA 1979 AN T fme AR gt Figure 1 310 E BERT The physical features of the PBR 310C E BERT are shown in Figure 1 System The chassis provides DC power and cooling for the PBR 310 The chassis has LEDs that indicate the status of the electrical power supply and the fan Generator 9 23 31 The pattern generator produces PRBS 2 1 2
20. e is a risk of personal injury In addition the performance of this equipment may be reduced Moreover this alert mark is sometimes used with other marks and descriptions indicating other dangerous 2 When supplying the power to this equipment please make sure the 3 pin power cable to 3 pin grounded power outlet is well connected If a grounded power outlet is not available before supplying power to the equipment use a conversion adapter and ground the green wire or connect the frame ground on rear panel of this equipment to ground If power is supplied without grounding the equipment there is risk of receiving a severe or fatal electric shock 3 This equipment cannot be repaired by user DO NOT attempt to open the cabinet or disassemble internal parts without authorization Only Phytrex well trained service people or staff who get the authorization could service this equipment In addition there is a risk of damage to precision parts inside the equipment CAUTIONS 1 Before changing the fuse ALWAYS remove the power cord from the power outlet and replace the fuses Always use new fuses of the same type and rating specified on the fuse marking on the rear panel of cabinet 2 Keep the power supply and cooling fan free of dust Clean the power inlet regularly If dust accumulates around the power pin there is a risk of fire Keep the cooling fan clean and the ventilation holes are not obstructed If the ventilation is obst
21. eral status for pattern checker Table3 Status amp _ Not Synchronized Checking pattern No error yet Checking pattern Error detected 4 ing Finish checking No bit error 5 Finish checking Error detected 6 Error counter full Table 3 Pattern Checker Status and Lamp display 20 Innovative Transmission Tech Phytrex SERIAL E BERT Lamp Indicator SYNC Loss Indicates the synchronization was fail please check the pattern type and polarity on Error Detector if it is same as Generator or adjust the sync criteria threshold to more looser level Error The lamp will light on when error occur during the measuring period PASS No error occur or the bit error ratio BER is below the threshold during the measuring period Fail Error bit occur or bit error ratio BER is over the threshold during the measuring period Status The lamp will display in different color for different status under the measuring process Note Error Ratio Number of Error bit under the specified measuring time Number of total bits over the measuring period Error Count Number of error bits under the specified measuring period 21 PHYTRE Innovative Transmission Tech Phytrex SE RIAL E BERT Folder History This folder indicates the BER history expressed as table or histogram type Fig 10 shows the BER and relative information versus time hereafter we will make the brief
22. ercial Arbitration Rules of the American Arbitration Association by three arbitrators Each party shall appoint one arbitrator and together their appointees shall select a third arbitrator who shall have recognized expertise in communications technology Notwithstanding the foregoing the parties may apply to any court of competent jurisdiction for injunctive relief pending arbitration of substantive claims Costs of arbitration excluding attorneys fees shall be shared equally by the parties If any provision of this Agreement is be held by a tribunal of competent jurisdiction to be contrary to law the remaining provisions of this Agreement shall remain in full force and effect 12 ASSIGNMENT Licensee may not assign this Agreement or transfer a Software license to a legal entity separate from Licensee 42 Innovative Transmission Tech Phytrex SERIAL E BERT Customer Service and Contact Information Please contact Phytrex Technology Corp for customer service or sales support using the following Information World wide web www Phytrex com Sales information sales Phytrex com Contact Information Taiwan Phytrex Technology Corp Taipei 110 3F 2 189 Sec 2 Keelung Rd Xin Yi District Taipei Taiwan Tel 886 2 27352700 Hsinchu 300 8F 16 81 Shuli Rd Hsinchu Taiwan Tel 886 3 5169331 China Phytrex Technology Wuhan Corp Wuhan Tel 86 27 87259852 Fax 86 27 87810356 Email jerryyan Q phytrex co
23. g Firmware Input Variable VISA resource in COM Port connecting to PBR310 error in Check number that indicate whether the sub V1 1s work normal Output Result VISA resource out COM Port release for next sub vi error out Check number that indicate whether the sub vi is work normal DAPBR310XLabviewAPBR310 llbXSet EDC vi VISA resource in VISA resource out HOE error in no error Description Initialize the register variable in PBR 305 to make it ready to work 4 1 3 Set Pattern Generator Input Variable VISA resource in COM Port connecting to PBR305 User Edit 64bit user edit pattern set channel ch1 channel 1 ch2 channel 2 Data rate 8 5 11 2 Pattern 0 PRBS7 1 PRBS9 2 PRBS23 3 PBRS31 error out 4 User Edit PG on off Set true to start Pattern Generation error in Check number that indicate whether the sub viis work normal Output Result VISA resource out COM Port release for next sub vi 36 Innovative Transmission Tech Phytrex SERIAL E BERT error out Check number that indicate whether the sub viis work normal DAPBR310 Labview PBR310 b PATGEN_0403 vI User Edit VISA resource In VISA resource out set ad But PG PatternInvert error in no error Configuration for Pattern Generation 4 1 4 Set Pattern Checker Input Variable VISA resource in COM Port connecting to PBR310 set ch1 channel 1 ch2 channel 2 Pattern O PRBS7 1 PRBS9 2 PRBS2
24. in page of the GUI are illustrated In Fig 7 and it can be divided into four regions each folder will explained as belowing PT a ane ss Test Value _ ll Figure 10 PBR 310 GUI Show the BER history record according to the checking interval express as histogram and table versus time line EyeTrex M Eye diagram test mode Measuring the eye diagram parameters mask test and eye contour Item Description 1 Setting summary table providing user take a quick view about the setting parameters including Bit Rate Timer and Test Pattern 2 Testing Mode Select BER mode and Eye Diagram mode Table 2 Main page unction description 17 Innovative Transmission Tech Phytrex SERIAL E BERT Folder Setting User Interface BERT parameters On Off Set the generator output enable disable The default is On Channel 1 and Channel 2 can be active simultaneously Note Channel output disable will also shot down the error detector Pattern Invert Set the polarity of data pattern PBR 310C provide this function both on PPG side or ED side Data rate The Data Rate menu can set the bit stream data rate Select the desired data rate from the list OC 192 192 FEC 9 953 Gb s and 10 66 10 71 Gb s 8G 10G Fibre Channel FEC 8 533 Gb s 10 518 Gb s and 11 3125 Gb s 10Gigabit Ethernet FEC 10 3125Gb s 11 097Gb s Manual C
25. iodically with lint free wipes Texwipes 9 or Kimwipe and talcum free swabs soaked in optical grade 1sopropyl alcohol and then blown dry with inert dusting gas Tech Spray Duster 1671 Do not use freon based cleaners Follow ESD precautions when removing or inserting pluggable optics modules Although the modules can be removed or installed when the unit is powered up it is recommended that the System be powered down for changing optical modules 7 Use the USB adapter cable provided with the system to connect the serial interface to the standard USB COM port of a desktop or laptop PC PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Chapter 1 System Overview Introduction E BERT 310 15 an easy to use bit error ratio tester PBR 310 suited for research development and manufacturing environments The PBR 310 16 a very compact unit that incorporates electrical interfaces to a pattern generator and bit error analyzer It comes with an intuitive graphical user interface GUI and a comprehensive single screen display The E BERT PBR 310 has been designed to operate with few user settable parameters and with minimal training The System has a built in clock recovery mechanism that is typically not available in an integrated form in commercial bit error rate testers The System also has an intelligent data pattern synchronization feature that automatically initiates pattern synchronization when th
26. m Room 1701 Nan Fang Di Yuan Mansion No 568 Wuluo Rd Wuhan P R China 43
27. n a manner not specified by the manufacture may impair built in safety protection mechanisms provided by the equipment The E BERT system should be used in accordance with local and national electrical codes The power plug must be connected to a properly wired earth ground outlet receptacle An improperly wired power outlet could place hazardous voltages on accessible metal parts of the chassis The E BERT PBR 310 has electrical and optical ports Follow appropriate electrostatic discharge and optical eye safety precautions when using the PBR 310C ELECTRICAL CLASS I EQUIPMENT THIS EQUIPMENT MUST BE EARTHED Power plug must be connected to a properly wired earth ground outlet An improperly wired socket outlet could induce hazardous voltages on accessible metal parts Use the power cord supplied with the equipment ELECTRICAL AC MAIN CIRCUIT OVERLOADING When installing product consideration must be given to the accumulative nameplate rating when connecting the equipment to the AC supply wiring ELECTRICAL AUTOMATIC PRIMARY INPUT VOLTAGE ADJUSTMENT This product will automatically adjust to any voltage between the ranges shown on the datasheet Innovative Transmission Tech Phytrex SERIAL E BERT Safety Notification WARNING 1 Always refer to this manual when working near environment which the alert mark show on the left If operation is performed without heeding the advice in this operation manual ther
28. nt and Result Display 34 Innovative Transmission Tech Phytrex SERIAL E BERT Chapter 4 Labview Driver Programming Guide Introduction This chapter describes the functionality of the PBR 310 Labview Driver The main intention of the software is provided to support for the control of the to make the test and measurement programs Figure 35 Remote access and custom application development with PBR 310C VISA Driver for Labview Installation Installation the Labview diver must be under NI Labview 7 0 environment Step 1 Select E BERT Labview Diver exe to start installation LJ ihvtrex E BER Diver Setup E BERT datasheet pdf Ca setup exe ps Adobe Acrobat 7 0 Document Male 1 029 KB DT PHYTREX PBR 3D5 SETUP Setup C Step 2 Installation result in under the following folder Function panel gt gt Functions gt gt User Libraries gt gt E BER Figure 19 BER Labview Diver exe 35 Innovative Transmission Tech Phytrex SERIAL E BERT 4 Sub VI 4 1 1 COM Port Open Input Variable VISA resource in COM Port connecting to PBR10 Output Result VISA resource out COM Port release for next sub vi error out Check number that indicate whether the sub 1 1s work normal DAPBR310 Labview PBR310 lIb Open_0426 vi VISA resource in error out Open Com Port to start operating the PBR 310 4 1 2 Loadin
29. nts a simple and intuitive way of operating the PBR 310C It allows the user to easily set parameters and displays a comprehensive set of measurement results as well as module status on a single screen Components of the GUI PHITRE Access PBR 310 double click the PBR 310 icon to launch the system software the COM port setting screen will pop up to guide the user insert the COM port Please check the windows system device manager and insert the COM port properly Fig 8 PBR 310 system was required dual COM ports denote as Standard and Enhanced respectively From Fig 6 the Standard COM type is designed for BERT system control and sampling oscilloscope mode is occupied the Enhanced COM type Note PBR 310 software ver 1 9 4 will integrate Standard COM and Enhance into ID to simplify the process PHYTREES PHYTREEE Innovative Transmission Tech Innovative Transmission Tec Figure 9 Insert the Standard and Enhanced COM for version 1 9 3 1 Insert the ID number for version 1 9 4 2 and Quad Channel Mode for version 2 3 Version Version 1 9 3 Version 2 0 2 1 Version 1 9 4 COM Port Standard COM 1 Standard COM 2 ID 1 ID 2 Display Enhanced COM 1 Enhanced COM 2 Channels Dual Single Set Quad Dual Sets Dual Single Set Quad Dual Sets nci 1 Software Version Comparison Refer to Figure 9 16 Innovative Transmission Tech Phytrex SERIAL E BERT The ma
30. ompliance and Certification 34 Software License Aereement 40 Customer Service and Contact Information 42 Innovative Transmission Tech Phytrex SERIAL E BERT General Safety Intended Audience This document is intended for trained personnel in either telecommunications or networking environments who have a solid understanding of safety procedures around electricity and lasers WARNING ONLY TRAINED AND QUALIFIED PERSONNEL ARE ALLOWED TO OPERATE THIS EQUIPMENT Safety on Electricity Do not perform any action that creates a potential hazard to personnel or makes the equipment unsafe Observe the following guidelines when working with any electrical equipment Carefully examine the entire work area for possible hazards such as wet floors ungrounded power extension cables and missing safety grounds before beginning work e Disconnect the power cords from the equipment whenever possible Make sure that power cord is readily identifiable and easily reached Disconnect all external cables before installing or removing Failure to ensure adequate grounding can cause product damage and can make the product dangerous Never install equipment that appears damaged e Never position the equipment where it is difficult to operate the disconnecting device appliance coupler Use of this equipment i
31. ontinuous rate from 8 5G s 11 3Gb s Data rates can be changed at any time during operation Allow 1 2 seconds for a rate change to take effect The default is 10 Gb s Test Pattern This pull down list allows selection of one of the PRBS data patterns 7 23 31 31 PRBS 2 1 2 1 2 1 the default is PRBS 2 1 Sync Criteria Sync Success Sync Loss state judgment is performed by Sync Criteria value In the sync success state when the error ratio less than the Sync Criteria value if the error ratio exceed the criteria the sync loss state 1s judged In the sync loss state pattern synchronization 15 not established and measurements cannot be made However when the error ratio 1s smaller than the Sync Criteria value pattern synchronization is established As Sync Criteria is either of 1 to 1E 10 can be selected BER Threshold The pass fail criteria judgment 1s achieved through this level setting Under the fail condition 1s judged if the bit error ratio is exceed the BER Threshold BERT Threshold range can be set from1E 0 to 1E 15 Measuring Time This window allows the user to indicate the time over which the BER is to be accumulated The default value 1s one The measuring time can be changed at any time during operation Checking Interval This window allows the user to set the checking time of error detector The default value is 0 55 500ms Exit Program To stop and quite the PBR 310 GUI when pressing the bottom
32. p Screen 24 Innovative Transmission Tech Phytrex SERIAL E BERT Measuring Channel 1 Waveform acquisition Process Status Standard Mask Polygon w o Mask Margin Time Base Scale Div Vertical Scale Div Eye Amplitude pp Jitter pp Jitter RMS Rising Time 20 80 Fall Time 20 80 Data Rate Eye SNR Mask Violation Hit No Figure 16 Eye Diagram Display and Test Result gt Perform the Self Test Cable Connection 1 Channel 1 Data Data Output Scope Data Data Input 2 Channel 2 PPG Data Data Output Scope Data Data Input Please add 50Ohm load with non use port when perform with single end connection GUI Operation 1 Setting Data Rate and Pattern Type enable the Channel Channel 2 PPG Y 2 Select EyeTrex Mode and EyeTrex Folder to perform the Eye Diagram Test 3 Press Setup button select the Eye Diagram testing parameters and enable the mask test Y 4 Press Single Repeat button to switch the testing mode 5 Press Get Eye button to acquire the Eye diagram 25 PHY TRESS Phytrex SERIAL E BERT Setting BER History Pattren Channel 1 PRBS31 Channel 2 PRBS31 Error Detect EyeTrex Eye Monitor Get Eye ps div Setup Single EXIT EyeTrex Figure 17 8 533Gb s PRBS31 30 Mask Margin BER Setting NEL CHI CH History EyeTrex Error Detect EyeTrex Eye Monitor Get Eye mV div ps
33. ransmission Tech Phytrex SERIAL E BERT 1 Reference Clock Output 1 64 to synchronize with external PBR 310C Master 2 Reference Clock Input 1 64 to synchronize from external PBR 310C Slave 3 Recovery Clock Output from Error Check Data Input 4 Re drive Data Output from Channel 1 Error Checker 5 Re drive Data Output from Channel 2 Error Checker I Note 1 Ch 2 or Ch4 is available when system installs option 01 2 Scope eyetrex function is available when system installs option 05 06 Electrical Specification Differential AC coupled Data Amplitude 320m Vpp Single Ended Output ee Fall Time 8 5 11 1Gb s 20 80 8 5 11 1Gb s 25 ps No 5 ED Differential AC coupled ror Checker Data 8 5711 3Gb s Data In wo Input Sensitivity lt 60 mVpp Single ended a Error Checker 60 400 mVpp Single ended Y Differential AC coupled u lt 6omvpp Single ended ks ss 60 400 mVpp Single ended Data In Data In Re driver Differential AC coupled Auxt 2 Data DataRoute Route From ED Data Input o Data Dala Output Rise Fall Time 8 5 11 1Gb s lt 42 In In 2066 8090 Jitterp p Jitterp p p 8 5 11 1Gb s L Out Out Recovery Differential AC Couple 64 of Data Rat e Hd o PS Data In Data In EM lt a 10 Innovative Transmission Tech Phytrex SERIAL E BERT PC
34. ronized Checking pattern No error yet Checking pattern Error detected Finish checking No bit error Finish checking Error detected Error counter full error out Check number that indicate whether the sub viis work normal DAPBR3lOWXLabview PBR310 lIbxGet Patchk1 vi VISA resource in VISA resource out Channel p 2 Result set m error out error in set Datarate Timer Result Total Bits Error Count Timer BER Status Get Pattern Check Result 38 PHYTREES Innovative Transmission Tech Phytrex SERIAL E BERT Sample code PBR310_STD_4 Foss Pus TE E jo 7 1 Tu2 N3S1vd B Innovative Transmission Tech Phytrex SERIAL E BERT Compliance and Certification FCC Part 15 Compliance This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense
35. ructed the cabinet may over heat Innovative Transmission Tech Phytrex SERIAL E BERT System Specifications The PBR 310 is intended for indoor controlled environment use only Environmental Acoustic Noise Relative Humidity Electrical Electrical Rating Mains voltage fluctuations Transient Physical Dimensions Net Weight 60 dBA maximum Operating 5 to 40 Storage 0 C to 70 C Operating non condensing 5 to 85 continuous Storage non condensing 5 to 95 100 to 240 VAC 1 4A 50 60 Hz 10 Transient Overvoltage Category II L 375mm X W 275mm X H 85mm PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Handling Precautions 1 310 is intended for operation at an ambient temperature of 25 degrees Centigrade 2 Adequate airflow should be provided to the PBR 310 to maintain the required ambient thermal conditions 3 Ensure that the PBR 310 power supply and all equipment used with it have properly earthed ac power supplies 4 Standard precautions against electrostatic discharge ESD must be followed while handling the PBR 310 Terminate unused electrical output ports with 50 ohm connected to ground The PBR 310 must be operated in a dust free environment Keep unused ports capped Particular care must be taken to ensure that the optical connectors are kept clean It is recommended that the connector surfaces and exposed parts be cleaned per
36. sign sublicense or otherwise convey the Software to another party or b cause or permit reverse engineering disassembly or decompilation of the Software With respect to GUI this License is limited to use solely on the Designated Systems 3 OWNERSHIP PHYTREX RETAINS ALL RIGHTS NOT EXPRESSLY GRANTED TO LICENSEE IN THIS LICENSE The Software is the confidential and proprietary product of Phytrex and is protected by copyright trade secret and other intellectual property law Phytrex shall at all times retain all right title and interest including all intellectual property rights in the Software Licensee is granted only the right to use the Software and does not acquire any rights express or implied in the Software other than those specified in this License Licensee shall not disclose and shall exercise all reasonable precautions to prevent access to or disclosure of the Software except to persons whose access to it is necessary for the effective and efficient use of the Software and Phytrex s hardware by Licensee Licensee shall be responsible for all damages caused by unauthorized disclosure or copying by persons having access to the Software in the possession of Licensee Subject to the rights of Phytrex in and to the Software and Derivative Works created by the Licensee Licensee will have sole and exclusive title to the Derivative Works created within the scope of the license granted herein Notwithstanding the assignment of ownership Phy
37. stallation disk and System User Manual The PBR 310 s power supply can be connected to any AC outlet with a rating of 100 240 VAC 50 60 Hz It draws a maximum of 0 5A Use of conditioned AC power is recommended Following item 15 the operation procedure I II III IV Place the System on a tabletop or similar flat surface It is recommended that the air in the vicinity of the System be relatively free of dust and heavy particulates Excessive dust can damage fan and other internal components and cause overheating Connect the terminator on unused channel Connect the USB connector of the serial interface cable to the desktop or laptop PC to launch the E BERT GUI Graphical User Interface will be run Connect the USB connector of the cable to the E BERT rear panel Use the AC power cable included with the System to connect the unit to the AC power outlet To avoid the chance of electric shock attach the power cord to the E BERT chassis before inserting the plug into the AC power outlet Turn the AC power on The front panel LEDs should glow steadily PHYTRE Innovative Transmission Tech Phytrex SERIAL E BERT Software Installation The PBR 310 GUI is a LabVIEW application operating under Microsoft Windows XP l and Windows 7 operating systems The E BERT GUI needs LabVIEW 7 1 Run Time Engine to be Installed on the PC connected to the E BERT System executable versions of the application and the Run Time Engin
38. trex reserves the right to use and create the same or similar Derivative Works without infringing on the ownership rights of the Licensee 4 WARRANTY THE SOFTWARE IS LICENSED TO LICENSEE 5 IS AND IS FREE OF ANY EXPRESS OF IMPLIED WARRANTY THAT THE SOFTWARE WILL OPERATE CONTINUOUSLY OR BE ERROR FREE TO THE FULL EXTENT ALLOWED BY LAW PHYTREX DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 5 INDEMNIFICATION Licensee shall indemnify Phytrex and its directors officers employees and agents and defend and hold each of them harmless from and against any and all losses damages liabilities costs and expenses including reasonable attorney s fees and expenses in connection with any and all third party liability suits investigations claims or demands collectively Losses arising from or occurring as a result of Licensee s activities with respect to the Software and Derivative Works Licensee shall at its expense pay for all costs and attorney s fees in defending any action brought against Phytrex based on a claim that Licensee s activities with respect to the Software and Derivative Works infringes any patents copyrights trademarks or other proprietary or intellectual property right of any third party Each party shall immediately notify the other party in writing of such a claim IN NO EVENT WILL PHYTREX INDEMNIFY LICENSEE OR ANY THIRD PARTY OR BE LIABLE FOR ANY DAMAGES AWARDED TO LICENSEE OR SUCH THIRD PARTY