Home

OptoLyzer Suite Start-up Guide V1-00-XX-7 Application Note

image

Contents

1. 2 Oo Login in as a user with administrator rights Install the MOST Tool Kit This step covers the installation of a MOST PC Interface the installation of drivers and the installation of the MOST Tool Foundation For details refer to the corresponding install guide that can be found on the MOST Tool Kit CD Install the OptoLyzer Components and the OptoLyzer Suite Both installers can be found on the OptoLyzer Suite installation CD A detailed description can also be found in section 3 2 on page 16 After completion of the installation steps start the MOST Tool Kit Configurator Click Start All Programs K2L MOST Tool Foundation MOST Tool Kit Configurator Select the desired MOST PC Interface and click Set as Default Start the OptoLyzer Suite Click Start All Programs K2L OptoLyzer Suite OptoLyzer Suite Press F1 for accessing the online help Add a MOST PC Interface like it is described in the online help Hint Use the Search dialog and type Add a new MOST PC Interface Further details around the MOST PC Interface support of the OptoLyzer Suite are explained by the context sensitive online help Additionally use the Search dialog to access specific topics Start up Guide Page 28 OptoLyzer Suite 9 Firewall Settings If a firewall is installed on the laptop PC the firewall settings must be adapted for the connected OptoLyzer OL3XXX In order to build up a connection to the
2. OptoLyzer OL3XXX ask the corporate IT administrator for help e g to define a trusted subnet IP address 169 254 00 Subnet mask 255 255 0 0 port numbers 27994 up to 28004 for both protocols UDP and TCP 9 1 Set Port Number in Windows XP In the following example the specification of an exception is described for port number 28004 and protocol TCP The same procedure has to be performed for the entire port number range 27994 up to 28004 for both protocols UDP and TCP 1 Login as a user with administrator rights 2 Start Control Panel 3 Start Windows Firewall If another application is used for maintaining the firewall ask the corporate administrator for help Switch to tab Exceptions Click Add Port Enter the port number e g 28004 and a friendly name Select the TCP radio button and click OK UG OT Re Start up Guide Page 29 OptoLyzer Suite 9 2 Set Port Number in Windows 7 In the following example the specification of an exception is described for port number 28004 and protocol TCP The same procedure has to be performed for the entire port number range 27994 up to 28004 for both protocols UDP and TCP Login as a user with administrator rights Click the Start Button Type Firewall in the search box Click Windows Firewall in the results In the left pane click Advanced settings If you re prompted for an administrator password or confirmation type the password or pro
3. 31 Start up Guide Page 4 OptoLyzer Suite 1 Preface 1 1 Intended Use This K2L product is intended to be used for developing testing or analyzing MOST and MediaLB based multimedia products and systems by persons with experience in developing multimedia devices Use this K2L product only with original K2L devices 1 2 Software on the CD The OptoLyzer Suite installation CD includes Installer of the OptoLyzer Suite including online help drivers e g for MediaLB and OptoLyzer Suite Viewer Installer of the OptoLyzer Components Tool OfflineTimeSyncFileMerge User manuals Start up Guide Page 5 OptoLyzer Suite 1 3 Information Sources 1 Start up Guide this document It describes in a brief manner how e to connect the hardware components of the OptoLyzer OL3XXX to the PC running the OptoLyzer Suite e to connect the hardware components of the MediaLB Analyzer V2 0 1 to the PC running the OptoLyzer Suite e to install the OptoLyzer Suite supporting analysis and verification of MOST network and MediaLB signal data Hardware Manual OptoLyzer OL3XXX 1 It describes all features functionality and technical specifications of the OptoLyzer OL3XXX hardware in detail MediaLB Analyzer Hardware Manual 2 It describes the MediaLB Monitor and the MediaLB Active Pods 3 Pin and 6 Pin Online help of the OptoLyzer Suite 3 It describes the software usage in detail Whenever help is needed in th
4. 4 x y Subnet Mask 255 255 0 0 2 PC must also have an APIPA address to enable communication Check with IPCONFIG command on Windows command line a b c d e Click Start gt Run Enter cmd in order to open a command shell Enter ipconfig and press Return The current values of IP and the Subnet Mask are shown Check whether they are matching to the values in step 1 3 PC must not use a static IP on its Ethernet interface Click Start gt Settings gt Control Panel Double click Network Connections Select the connection that is connected to the OptoLyzer OL3XXX Right click to open the context menu Select Properties Start up Guide Page 12 OptoLyzer Suite Internet Protocol TCP IP Properties General Altemate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address Obtain DNS server address automatically Use the following DNS server addresses Figure 3 2 Internet Protocol Properties f If not done select the settings as shown above so that the IP address is obtained automatically g Press the Ok button If necessary follow the system instructions h After this is done wait up until a minute then press the Refresh button of th
5. Figure 5 1 MediaLB Analyzer Overview The steps are based on Figure 5 1 and explained from left to right 1 Connect the Active Pod 2 to the MediaLB port of the DUT 1 by directly plugging it onto a dedicated MediaLB Debug Connector For the pin assignment refer to the delivered MediaLB Analyzer Hardware Manual 2 2 Connect the Active Pod 2 and the MediaLB Monitor 3 via the delivered cable 3 Connect power supply to the MediaLB Monitor 3 4 Connect MediaLB Monitor 3 and Host PC laptop 4 with the USB cable which is part of the delivery 5 Proceed with the USB driver installation described in section 5 3 The USB connector on the PC has to be a USB 2 0 High Speed connector 5 Check it in the Device Manager If the Device Manager shows an Enhanced USB Host Controller the connector has USB 2 0 High Speed capability Start up Guide Page 23 OptoLyzer Suite 5 3 USB Driver Installation After connecting the MediaLB Monitor 3 to the USB 2 0 High Speed Port 5 of the PC laptop 4 the hardware wizard opens with the recommended installation preselected 1 Follow the steps After clicking Finish the hardware wizard opens again recommended installation preselected for continuing installation Follow the steps Click Finish The hardware is installed 5 4 Work with the MediaLB Feature of the OptoLyzer Suite 1 2 3 Start OptoLyzer Suite 6 Press F1 for accessing the online help Add a
6. K2L de Direct contact information is available at http www K2L de contact K2L GmbH Bannwaldallee 48 D 76185 Karlsruhe GERMANY Technical Support Contact information for technical support is available at support K2L de Start up Guide Page 2 OptoLyzer Suite Table of Contents 1 PREFACE Intended Use Software on the CD Information Sources Term Definitions 1 1 1 1 2 INTRODUCTION 2 2 2 Pon 1 Features 2 PC System Requirements 3 Licensing 3 USE WITH AN OPTOLYZER OL3XXX 3 1 Connect to the OptoLyzer OL3XXX 3 1 1 Direct Connection via Cross link Cable 3 1 2 Direct Connection via USB Ethernet Adapter 3 1 3 Connection via Corporate Network 3 2 Basic Steps 3 3 OptoLyzer Suite Update Procedure 4 USE STANDALONE OFFLINE ANALYSIS 4 1 OptoLyzer Suite Update Procedure 5 USE WITH A MEDIALB MONITOR 5 1 Installation of OptoLyzer Suite 5 2 Connect the MediaLB Analyzer 5 3 USB Driver Installation 5 4 Work with the MediaLB Feature of the OptoLyzer Suite 5 5 Update Procedure 6 USE WITH OPTOLYZER MOCCA COMPACT 50E 7 USE WITH OPTOLYZER MOCCA COMPACT 1500 8 USE WITH MOST PC INTERFACES 9 FIREWALL SETTINGS 9 1 Set Port Number in Windows XP O NOA 0 9 10 10 11 11 12 14 15 16 18 19 20 21 22 23 24 24 25 26 27 28 29 29 Start up Guide Page 3 OptoLyzer Suite 9 2 Set Port Number in Windows 7 APPENDIX A LIST OF FIGURES APPENDIX B LIST OF TABLES 30 31
7. MediaLB USB device like it is described in the online help Hint Use the Search dialog and type Add a new MediaLB USB device For starting your work quickly and most efficient refer to the following sections of the online help Again use the Search dialog and type the following e MediaLB Level1 gt this section describes the creation of MediaLB Transmission Events e Predefined MediaLB Workspace gt this section explains how to access predefined tabs for filtering on specific signals data Further details around the MediaLB support of the OptoLyzer Suite are explained by the context sensitive online help Additionally use the Search dialog to access specific topics Start up Guide Page 24 OptoLyzer Suite 5 5 Update Procedure The update procedure covers two major blocks the installation of the new software versions of OptoLyzer Suite and maybe OptoLyzer Components and the reconnection of the MediaLB Monitor The following steps have to be performed 1 2 Login in as a user with administrator rights Click Start All Programs K2L OptoLyzer Suite Check for OptoLyzer Suite Updates Both OptoLyzer Suite and OptoLyzer Components updates are shown Follow the instructions After completion of the software installation disconnect all cables from the MediaLB Monitor see Figure 5 1 on page 23 Reconnect all cables as described in section 5 2 on page 23 This causes an automa
8. OptoLyzer Suite 7 Use with OptoLyzer MOCCA compact 1500 If the OptoLyzer Suite is used together with an OptoLyzer MOCCA compact 1500 follow these steps 1 2 Login in as a user with administrator rights Install the MOCCA Connector a software layer on the PC that connects the OptoLyzer MOCCA compact 1500 with the OptoLyzer Suite Therefore refer to its documentation and open the current version of the document How To Install MOCCA compact OptoLyzer Suite and follow the instructions After completion of the installation steps start the MOST Tool Kit Configurator Click Start All Programs K2L MOST Tool Foundation MOST Tool Kit Configurator Select the desired OptoLyzer MOCCA compact 1500 and click Set as Default Start the OptoLyzer Suite Click Start All Programs K2L OptoLyzer Suite OptoLyzer Suite Press F1 for accessing the online help Add an OptoLyzer MOCCA compact 1500 like it is described in the online help Hint Use the Search dialog and type Add a new OptoLyzer MOCCA compact 1500 Further details around the OptoLyzer MOCCA compact 1500 support of the OptoLyzer Suite are explained by the context sensitive online help Additionally use the Search dialog to access specific topics Start up Guide Page 27 OptoLyzer Suite 8 Use with MOST PC Interfaces If the OptoLyzer Suite is used together with a MOST PC Interface follow these steps 1
9. SK2L CONNECTING NETWORKS Multimedia and Control Networking Technology OptoLyzer Suite Start up Guide V1 10 X Document Information Version V1 0 X 7 Date 2013 07 04 MOST Media Oriented Systems Transport OptoLyzer Suite Legend Copyright 2008 2013 K2L GmbH All rights reserved Please make sure that all information within a document marked as Confidential or Restricted Access is handled solely in accordance with the agreement pursuant to which it is provided and is not reproduced or disclosed to others without the prior written consent of K2L The confidential ranking of a document can be found in the footer of every page This document supersedes and replaces all information previously supplied The technical information in this document loses its validity with the next edition Although the information is believed to be accurate no responsibility is assumed for inaccuracies Specifications and other documents mentioned in this document are subject to change without notice K2L reserves the right to make changes to this document and to the products at any time without notice Neither the provision of this information nor the sale of the described products conveys any licenses under any patent rights or other intellectual property rights of K2L or others The products may contain design defects or errors known as anomalies including but not necessarily limited to any which may be identified in this document whic
10. can be located somewhere in the Ethernet network or can be connected directly alternatively via USB Unlike the hardware component the software operates independently from any environmental network characteristics such as physical layer properties It can be seen as an upper layer extendable by a wide range of software extensions supporting further analysis or allowing to run tests automatically Nevertheless hardware extensions for e g data logging are also applicable All extensions whether hardware or software sided can be used without consideration of any network features Start up Guide Page 8 OptoLyzer Suite 2 1 Features Support of MOST150 MOST50 and MOST25 networks Support of MOST networks basing on optical or electrical Physical Layer Support of OptoLyzer OL3XXX MediaLB Monitor OptoLyzer MOCCA compact variants and MOST PC Interfaces Support of online and offline analysis and debugging Full bandwidth spy for control packet and streaming data analysis MOST network state tracking e g light lock SBC MPR NPR Powerful viewing and coloring of all network events Flexible filtering and triggering Fully customizable Viewers to view and analyze data traffic Control Packet and Streaming data Recording of MOST messages Control Packet and Streaming data Input Triggers and Keyboard Events Storing spy data in img xml op2 txt format Graphical interpretation of the data in a Graph Focusing and di
11. e OptoLyzer Suite main window and Viewer Recorder Graph and Watch In addition the Transceiver and the MOST Interface Control can be started in the OptoLyzer Suite OptoLyzer Suite This is a stripped down version of the full OptoLyzer Suite but free Viewer of charge It offers first limited possibilities with regard to offline analyzing recorded files A Trigger defines when to capture data from MediaLB Table 1 1 Term Definitions Start up Guide Page 7 OptoLyzer Suite 2 Introduction The OptoLyzer Suite software is a state of the art analysis tool that allows analyzing monitoring and debugging control packet and streaming data traffic on the MOST network and on the MediaLB The OptoLyzer Suite is an easy to handle user software based on an intuitive usage concept supported by a comfortable online help It can operate in combination with an OptoLyzer OL3XXX offering both on and offline analysis of MOST data chapter 3 stand alone offering offline analysis of MOST and MediaLB chapter 4 or in combination with MediaLB Monitor and Active Pod MediaLB 3 Pin and 6 Pin supporting analyzing and visualizing of MediaLB data online chapter 5 It also supports MOST PC Interfaces and OptoLyzer MOCCA compact variants Recorded files hardware triggers and the network traffic on the MOST network can serve as data sources The OptoLyzer Suite must be installed on a client PC with Ethernet connectivity The client PC
12. e OptoLyzer Suite press F1 Then use e g the Search functionality in the help Media Local Bus Specification 4 It defines the MediaLB Physical Layer and Link Layer Protocol Start up Guide Page 6 OptoLyzer Suite 1 4 Term Definitions Definitions Active Pod Part of the MediaLB Analyzer It is a small housing that is directly MediaLB 3 Pin connected to the MediaLB Debug Header of the DUT It buffers Active Pod the MediaLB signals and transfers them to the MediaLB Monitor MediaLB 6 Pin without compromising the signal integrity PC additional or target PC DHCP Dynamic Host Configuration Protocol a common TCPIP standard ONS fordynamis assignment of P accesses and Pcontigurations the shipped cross link cable Intelligent Network Interface Controller MBI Message Based interface from the Active Pod via USB to the Host PC OptoLyzer MOCCA Multibus hardware interface from K2L compact 50e OptoLyzer MOCCA compact 1500 MOST PC Interface Generic term that covers e g MOST PCI Interface 250 NIC MOST PCI Interface 250 MOST PCI Interface 50e MOST PCI Interface 1500 OptoLyzer Tool covering developer interfaces and components used as base Components for several tools OptoLyzer OL3XXX Hardware of the OptoLyzer G2 3XXX e g OptoLyzer OL30250 OptoLyzer OL3050e or OptoLyzer OL31500 OptoLyzer Suite This is the software of the OptoLyzer G2 30250 OptoLyzer G2 3050e and or OptoLyzer G2 31500 It covers th
13. e property window of the OptoLyzer OL3XXX The OptoLyzer OL3XXX can transfer data to the PC at full bandwidth Start up Guide Page 13 OptoLyzer Suite 3 1 2 Direct Connection via USB Ethernet Adapter OptoLyzer OL3XXX can be exclusively used by the laptop user Hub Switch Optional Ethernet interfaces Ethernet Connection USB Connection Laptop or PC ul USB Ethernet O Z Adapter Ethernet Connection OptoLyzer OL3XXX Figure 3 3 Direct Connection via USB Ethernet Adapter 1 Here apply the same restrictions and configuration for the IP addresses of OptoLyzer OL3XXX and PC as for the connection via cross link cable see above on page 12 2 PC must not use a static IP on its USB Ethernet interface The PC has full access to the corporate network Start up Guide Page 14 OptoLyzer Suite 3 1 3 Connection via Corporate Network From your laptop PC you have comfortable remote access to several OptoLyzer OL3XXX hooked up to your company network Ethernet interface 100Base T Corporate network Laptop or PC Hub Switch 100Base T OptoLyzer OL3XXX Figure 3 4 Connection via Corporate Network 1 OptoLyzer OL3XXX must be allowed to obtain a valid IP address from the corporate DHCP server 2 A minimum bandwidth of 6 MBytes s on the Ethernet connection is required for each OptoLyzer OL3XXX to handle its data 3 Check firewall settings of yo
14. gure 5 1 on page 23 is not connected to the PC laptop If it is connected disconnect the device and remove power supply and Active Pod 2 Install the OptoLyzer Suite on the connected PC or Laptop using the OptoLyzer Suite installation CD Perform the following steps a Login in as a user with administrator rights b Insert the OptoLyzer Suite installation CD in a CD drive of the PC c The auto run mechanism starts the CD If no auto run mechanism is supported execute the Launch exe that can be found on the CD d Inthe CD menu click Install e Click Install OptoLyzer Components f Install it on the PC Follow the instructions If the installer detects an older version of OptoLyzer Components remove it first if not done automatically Then start the installation again g After completing the installation of OptoLyzer Components click Install OptoLyzer Suite current version h Install it on the PC Follow the instructions 3 Proceed with the hardware installation described in section 5 2 Start up Guide Page 22 OptoLyzer Suite 5 2 Connect the MediaLB Analyzer Figure 5 1 gives an overview of the entire MediaLB Analyzer and depicts how the single components are arranged Optolyzer Suite with MedisLB Support MediaLB USB 2 0 High Speed 3 8 pin Port lan Se ModiaLB Monitor nae gt 3 7 an our 2 Host PC Laptop 4 usa29 Short Cable Connection Cable Connection
15. h may cause the product to deviate from published descriptions Anomalies are described in errata sheets available upon request K2L products are not designed intended authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property damage Any and all such uses without prior written approval of an officer of K2L will be fully at your own risk The K2L logo is a trademark of K2L Other names mentioned may be trademarks of their respective holders K2L disclaims and excludes any and all warranties including without limitation any and all implied warranties of merchantability fitness for a particular purpose title and against infringement and the like and any and all warranties arising from any course of dealing or usage of trade In no event shall K2L be liable for any direct incidental indirect special punitive or consequential damages or for lost data profits savings or revenues of any kind regardless of the form of action whether based on contract tort negligence of K2L or others strict liability breach of warranty or otherwise whether or not any remedy of buyer is held to have failed of its essential purpose and whether or not K2L has been advised of the possibility of such damages Further Information For more information on K2L s automotive products software and MOST development tools and modules visit our web site http www
16. he auto run mechanism starts the CD If no auto run mechanism is supported execute the Launch exe that can be found on the CD In the CD menu click Install Click Install OptoLyzer Components Install it on the PC Follow the instructions If the installer detects an older version of OptoLyzer Components remove it first if not done automatically Then start the installation again After completing the installation of OptoLyzer Components click Install OptoLyzer Suite current version Install it on the PC Follow the instructions 2 Remove the CD Plug the USB dongle WIBU KEY on the PC The WIBU KEY is part of the shipment Start up Guide Page 19 OptoLyzer Suite 3 Use Online Help of OptoLyzer Suite a Start OptoLyzer Suite b Press Fi to access the online help c Click on Overview at the top of the Contents tab d Click on Add First OptoLyzer OL3XXX located in the Getting Started section of the help text Further details around the OptoLyzer Suite are explained by the context sensitive online help Additionally use the How Do section to get familiar with basic topics 4 1 OptoLyzer Suite Update Procedure If the OptoLyzer Suite has to be updated perform the following steps 1 Login in as a user with administrator rights 2 Remove the old version of OptoLyzer Suite Use the standard mechanism of Windows 3 Download the new version of OptoLyzer Suite from our homepage htt
17. p www K2L de Then double click the installer and follow the instructions 4 Ifthe OptoLyzer Suite installation procedure requires also to install a new version of OptoLyzer Components first remove the old version of OptoLyzer Components Use the standard mechanism of Windows 5 Download the new version of OptoLyzer Components from our homepage http www K2L de 6 Afterwards double click the installer and follow the instructions Start up Guide Page 20 OptoLyzer Suite 5 Use with a MediaLB Monitor For analyzing and debugging MediaLB data online the MediaLB Monitor has to be connected to a client PC the OptoLyzer Suite software is running You have to perform the steps described in the following sections Start up Guide Page 21 OptoLyzer Suite 5 1 Installation of OptoLyzer Suite To run the MediaLB Analyzer you need to have OptoLyzer Suite V1 4 3 or newer installed If you run an OptoLyzer Suite version older than V1 4 3 you need to de install the program Use the standard mechanism of Windows Start the Control Panel click Add or Remove Programs and remove current version of OptoLyzer Components In this case start installation of MediaLB Analyzer with the steps described below in this section If you already run OptoLyzer Suite V1 4 3 or a newer version start installation of the MediaLB Analyzer with the steps described in the following sections 1 Check if MediaLB Monitor 3 see Fi
18. p of OptoLyzer Suite a Start OptoLyzer Suite b Press Fi to access the online help c Click on Overview at the top of the Contents tab d Click on Add First OptoLyzer OL3XXX located in the Getting Started section of the help text Further details around the OptoLyzer Suite are explained by the context sensitive online help Additionally use the How Do l section to get familiar with basic topics Check the Firewall Settings on page 29 for the ports used in OptoLyzer Suite Start up Guide Page 17 OptoLyzer Suite 3 3 OptoLyzer Suite Update Procedure If the OptoLyzer Suite has to be updated perform the following steps 1 Login in as a user with administrator rights 2 Click Start All Programs K2L OptoLyzer Suite Check for OptoLyzer Suite Updates Both OptoLyzer Suite and OptoLyzer Components updates are shown 3 Follow the instructions Start up Guide Page 18 OptoLyzer Suite 4 Use Standalone Offline Analysis If you use the OptoLyzer Suite standalone i e without connecting the PC to an OptoLyzer OL3XXX or to a MediaLB Monitor you are able to analyze MOST or MediaLB data offline Perform the following steps 1 Install the OptoLyzer Suite on the connected PC or Laptop using the OptoLyzer Suite installation CD Perform the following steps a b h Login in as a user with administrator rights Insert the OptoLyzer Suite installation CD in a CD drive of the PC T
19. splaying of specific Events in a Watch Smart GUI customization according to user s preferences Data recovery in all modes bypass master slave Node control software MOST Interface Control and Transceiver Software Powerful helpers e g syntax tree support of PBN and XML files Graphical user interfaces supporting sending and receiving of Control data and sending of MBI messages MediaLB support Beagle Feeder support RS232 Feeder support File Feeder support High level access to Plug Ins INIC Remote Viewer MOST Radar DTCP Viewer MOST System Radar MOST Rapid Control Start up Guide Page 9 OptoLyzer Suite 2 2 PC System Requirements The following environment minimum is recommended for installation 1 Pentium IV Class PC with hyper threading technology or dual core processor with 2 66 GHz 2 2GByte RAM 3 1 GByte free disk space additional storage for recording required 4 Ethernet alternatively USB2 0 High Speed and adapter for connecting an OptoLyzer OL3XXX 5 USB2 0 High Speed for connecting an MediaLB Monitor 6 Windows XP SP3 or Windows 7 32 and 64 bits operating system 2 3 Licensing If the OptoLyzer Suite is used in combination with an OptoLyzer OL3XXX it is licensed by a license number stored in the OptoLyzer OL3XXX If the OptoLyzer Suite is used standalone it is licensed by a WIBU KEY plugged into the PC running OptoLyzer Suite If the OptoLyzer Suite is used in combination
20. tic update of the MediaLB Monitor firmware The firmware update of the MediaLB Monitor completes the update procedure Start up Guide Page 25 OptoLyzer Suite 6 Use with OptoLyzer MOCCA compact 50e If the OptoLyzer Suite is used together with an OptoLyzer MOCCA compact 50e follow these steps 1 2 Login in as a user with administrator rights Install the MOCCA Connector a software layer on the PC that connects the OptoLyzer MOCCA compact 50e with the OptoLyzer Suite Therefore refer to its documentation and open the current version of the document How To Install MOCCA compact OptoLyzer Suite and follow the instructions After completion of the installation steps start the MOST Tool Kit Configurator Click Start All Programs K2L MOST Tool Foundation MOST Tool Kit Configurator Select the desired OptoLyzer MOCCA compact 50e and click Set as Default Start the OptoLyzer Suite Click Start All Programs K2L OptoLyzer Suite OptoLyzer Suite Press F1 for accessing the online help Add an OptoLyzer MOCCA compact 50e like it is described in the onlinehelp Hint Use the Search dialog and type Add a new OptoLyzer MOCCA compact 50e Further details around the OptoLyzer MOCCA compact 50e support of the OptoLyzer Suite are explained by the context sensitive online help Additionally use the Search dialog to access specific topics Start up Guide Page 26
21. ur corporate network in case of connection problems port numbers 27994 up to 28004 for both protocols UDP and TCP must be accessible Start up Guide Page 15 OptoLyzer Suite 3 2 Basic Steps These basic steps have to be performed 1 Read the Hardware Manual OptoLyzer OL3XXX 1 and integrate the OptoLyzer OL3XXX in the MOST network 2 Connect the OptoLyzer OL3XXX to the PC the OptoLyzer Suite is running according to the connection concept you prefer as described in section Connect to the OptoLyzer OL3XXX on page 11 3 Install the OptoLyzer Suite on the connected PC or Laptop using the OptoLyzer Suite installation CD Perform the following steps a b Login in as a user with administrator rights Insert the OptoLyzer Suite installation CD in a CD drive of the PC The auto run mechanism starts the CD If no auto run mechanism is supported execute the Launch exe that can be found on the CD In the CD menu click Install Click Install OptoLyzer Components Install it on the PC Follow the instructions If the installer detects an older version of OptoLyzer Components remove it first if not done automatically Then start the installation again After completing the installation of OptoLyzer Components click Install OptoLyzer Suite current version Install it on the PC Follow the instructions Remove the CD Start up Guide Page 16 OptoLyzer Suite Use the online hel
22. vide confirmation In the left pane click Inbound Rules in the right pane click New Rules Click Port and Next Select TCP and specify the port number 28004 and click Next Select Allow the connection and click Next 0 Check the profile s as desired i e Domain Private Public and click Next 11 Enter a name and click Next 12 Repeat step 6 up to step 11 for Outbound Rules MRS D S OY OO Start up Guide Page 30 OptoLyzer Suite Appendix A List of Figures Figure 3 1 Direct Connection via Cross link Cable Figure 3 2 Internet Protocol Properties 0 eee 13 Figure 3 3 Direct Connection via USB Ethernet Adapter 14 Figure 3 4 Connection via Corporate Network essees 15 Figure 5 1 MediaLB Analyzer Overview s s s 23 Appendix B List of Tables Table 1 1 Term Definitions eeceeeeneeeeeeeneeeeeenaeeeeeeaaes 7 Start up Guide Page 31
23. with a MediaLB Monitor it is licensed by a license number stored in the MediaLB Monitor If the OptoLyzer Suite is used in combination with an OptoLyzer MOCCA compact 50e or OptoLyzer MOCCA compact 1500 it is licensed by a license number stored in the OptoLyzer MOCCA compact 50e or OptoLyzer MOCCA compact 1500 Start up Guide Page 10 OptoLyzer Suite 3 Use with an OptoLyzer OL3XXX In combination with the OptoLyzer OL3XXX the OptoLyzer Suite software allows online analyzing monitoring and debugging control packet and streaming data traffic on the MOST network K2L recommends to read the sections about connection concepts and to decide which of them you want to use Afterwards proceed with section Basic Steps on page 16 3 1 Connect to the OptoLyzer OL3XXX There are several possibilities how to connect an OptoLyzer OL3XXX Connection concepts e Direct Connection via Cross link Cable see page 12 This connection is recommended by K2L e Direct Connection via USB Ethernet Adapter see page 14 e Connection via Corporate Network see page 15 Start up Guide Page 11 OptoLyzer Suite 3 1 1 Direct Connection via Cross link Cable PC has no access to corporate network This is a typical connection setup in a lab or in the field car 100Base T Cross link cable Laptop or PC OptoLyzer OL3XXX Figure 3 1 Direct Connection via Cross link Cable 1 OptoLyzer OL3XXX has an APIPA address IP 169 25