1.       20    Type of connected card   The chronothermostat is capable of verifying  whether the socked is connected  If the socket  is not connected  the dashes will be displayed   it if is  the    rAd    writing will appear     Heating system actuator registration radio  control   It makes it possible  by pressing the     but   ton  to send the actuator registration radio con   trol used for the heating system  Refer to the   lt  lt Radio actuator configuration gt  gt  chapter for  more information     Humidity adjustment enable   It makes it possible to operate a humidistat  in order to humidify an environment until the  desired humidity level is reached  Refer to the   lt  lt Setting the desired humidity level gt  gt  chapter  for more information     Humidification system actuator registra   tion radio control   It makes it possible  by pressing the    button   to send the actuator registration radio control  used for the humidification system  Refer to  the  lt  lt Radio actuator configuration gt  gt  chapter    for more information  This menu item will be  displayed only if the humidity adjustment has  been enabled     Temperature scale   It selects the scale  i e  Celsius  centigrade  or  Fahrenheit degrees  by means of which all the  temperatures will be displayed  In the event  that the Fahrenheit scale is used  the tempera   tures may range from 0 0 to 99 9  F     Type of adjustment   It selects the temperature adjustment mode   differential  Std  or proportional  Pr
2.    23    Heating system actuator registration    1  Set the actuator to the    system code self   learning    mode  refer to the actuator instruc   tion sheet     2  Send the heating system actuator registra   tion radio control  refer to index 2 of the con   figuration menu   lt  lt Chronothermostat configu   ration gt  gt  chapter     2A  Press SET   PROG  button 6   The oper   ating mode currently used will be temporarily  interrupted    2B  Keep the SUMMER   WINTER switching  button  button 10  depressed for approximately  5 seconds  to display the initial page of the pro   gramming menu    2C  Press    gt   button 4  to select the second  parameter  the    rF t message will appear on  the display  the displayed index will be number  2    2D  Press     button 1  to send the heating  system actuator registration radio control  The     rF t    message will blink  verify that the actua   tor is registered after a few seconds    2E  Press ENTER  button 5  to go back to the  initial page of the programming menu  press  the same button again to go back to the oper   ating mode currently used     3  Repeat the operations described in steps 1  and 2 in the event that several actuators are  used     Humidification system actuator registration    1  Set the actuator to the    system code self   learning    mode  refer to the actuator instruc   tion sheet     2  Send the humidification system actuator  registration radio control  refer to indexes 3  and 3A of the configuration menu 
3.    INI GOSMI    THE ITALIAN TECHNOLOGY    Radio wave weekly program  chronothermostat  CH150RF   CH151RF   CH152RF    dla f at   iy a  Gu as    aE DAY z          INDEX   igi core  Uc  1 e  y enserre aeee 3   Controls and indications tacccccredessesseeececcesteiuncegeeece 4  CONOIS see a terre trent rete 4  Indicati  nS eepe a 5   User manual    eeeeeeeeseeeenrrrnteteeeeee rnrn nnenn eeen 6  Setting the date and time            cccceeeceeeesee esses 6  Summer Winter selection    assesseer 7  Operating modes siciesieesceots ence eeeseeetueceeensssendetas 7     Manual    operating mode               cccsscceeeceeeeeeees 7     Automatic    operating mode               ccceeeeeeeeeeees 8     Holiday    operating mode               cccccceeeeeeeeeees 10     Jolly    operating mode assctcecexetinearnnnadanctectscaments 10     OFF    fUNGIOM einoetenerenecrei ianareo reeni 12  Preset programS siiscnstscccadeiextaniemusincceeeeeniidavinns 13  Chronothermostat programming                  008 13    Displaying the temperature detected by the    separate probe cccuessvewvenceedcndveninanineeimenaseoomnnnnns 15    Statistical data Enemies ares een meta 15  Setting the desired humidity level                     16  Maintenance pee ree RE reer one ernment 17  Replacing the batteries              cccceeecsseeseeeeeees 17  MStallati  N pee re erent R 18  Installing the batteries 0 0 0    eececeeessesseeeeeees 18  Configuring the chronothermostat                     18  Actuator registration a
4.   lt  lt Chrono   thermostat configuration gt  gt  chapter     2A  Press SET   PROG  button 6   The oper   ating mode currently used will be temporarily  interrupted    2B  Keep the SUMMER   WINTER switching  button  button 10  depressed for approximately  5 seconds  to display the initial page of the pro   gramming menu    2C  Press    gt   button 4  until you select the third  parameter  the    rH    message will appear on  the display  the displayed index will be number  3   Verify that humidity adjustment is enabled   it must be set to    ON      otherwise  use the A   button 1  and VW  button 2  buttons to enable  the same    2D  Press     button 4  to display the next pa     24    rameter  the    rF rH    message will appear on  the display  the displayed index will be number  3A     2E  Press     button 1  to send the humidity  adjustment system actuator registration radio  control  The    rF rH    message will blink  verify  that the actuator is registered after a few sec   onds    2F  Press ENTER  button 5  to go back to the  initial page of the programming menu  press  the same button again to go back to the oper   ating mode currently used    3  Repeat the operations described in steps 1  and 2 in the event that several actuators are  used     Position the chronothermostat and the actua   tors at the chosen positions  then verify that  the signal quality is at least acceptable  the ac   tuators integrate a luminous signal to monitor  the radio signal quality      T
5.   pferiiga 20 8  ig 3 0   UREA       sd TT  2 06   ap ee    Li  4 Or   bic ie ste  Lae be ad     SSeS Si   FSP sa Oo cc          Z  a     FITS          pa    E                               2  The Monday profile  DAY 1  for    Winter    op   eration  icon f    will be displayed  Use the  lt   and  gt  buttons to move the bar chart blinking  segment to the time at which the temperature  is to be modified  Each segment equals half an  hour  To modify the    Summer    operation profile   icon        press the    Summer Winter    button  on the left side of the chronothermostat                                      dears  LOA  UUTEL nm  mun 1a pate ye    wat  nnn 1 8  ooo TI    00 Cee  i pay t A L  Jb bk  SIM JR Je roe  e IV JS Je Je   SS Om se oe O oe       3  Use the A and    buttons to modify the tem   pe level  T1  T2 or T3         BOO  ua dll TSI m  aaa   vane wane   in i fi woran    EEEH  _     _ TEREE            al rete JE L h oy l mlha ha  SIV IF IFIJFIJF I EOR JEE     nnn  fn i rr Lg  als nun wf fi                      SS      j     O                     4  To directly duplicate the temperature pro   file by going to the next day  press COPY  to  customize every single day separately  refer to  step 5 below            m3  Tid   TETA         dL alt  POUUUULUL ULL toot nun  Wes    nunnu   128 8  19 0 19 0  mg 1G          DAY 6 a   m    _  DUDUA    n a a a E O  Si SS O e                               5 Press ENTER to go to the next day  then  repeat the operations described 
6.  duration   It sets the maximum duration  hours  of the  preliminary ignition calculated by the optimiza   tion     Pump antiscuff   It turns the system on for 1 minute every day   h 23 58  by making the water circulating pump  to run  in order to prevent pump seizing  This  takes place only if the system has never been  turned on during the day     Software revision and radio address   It displays the software revision for the unit in  which the ambient temperature is usually in   dicated  and also the radio address in which  the three temperature T3  T2 and T1 are usu   ally displayed  By pressing the A and YW but   tons simultaneously for more than 4 seconds   you can change the chronothermostat radio  address  Following this procedure  the radio  actuators previously registered shall be con   figured again  refer to the  lt  lt Actuator registra   tion gt  gt  chapter      Actuator registration   Prior to starting up the system  the radio ac   tuators shall be registered to the CH150RF   CH151RF  CH152RF chronothermostat  To  avoid memorizing a code belonging to another  chronothermostat  the reception sensitivity  during the configuration procedure is reduced   therefore  the chronothermostat and the actua   tor should be positioned at a distance of less  than 2 m  Moreover  you should verify that the  radio socket is correctly connected with the  chronothermostat  refer to Index 1 of the con   figuration menu   lt  lt Chronothermostat configu   ration gt  gt  chapter   
7.  e Floor probe  FLO   when the temperature    detected by the probe reaches the value set in  the Floor temperature limit parameter  the sys   tem will be switched off regardless of the tem   perature detected by the chronothermostat     e Ambient probe  In   the system adjustment  is based on the temperature value detected by  the separate probe  This temperature will be  shown on the display in place of the one de   tected by the probe inside the chronothermo   stat  The separate ambient probe will be used  only when the chronothermostat is necessarily  situated in a different ambient from the one the  temperature of which is to be checked     e External probe  Out   it will not affect the  system adjustment and will be used to merely  know an extra temperature value  e g  the ex   ternal temperature     Floor temperature limit   It sets the temperature limit value read by the  separate probe which turns the system off  when the floor probe is used  for the floor heat   ing systems      22    Ambient temperature correction   It makes it possible to sum subtract an offset  value to from the temperature value measured  by the chronothermostat     Optimization   It calculates the spark lead required to reach  the desired temperature at the established  time  considering the system   s thermal inertia   The optimization takes place only on the first  switch on instance of the day  i e  on the first  programmed passage from a temperature to a  higher one     Optimization maximum
8.  for Saturdays and  Sundays  To create a customized    Holiday     program  refer to   Chronothermostat program   ming          Jolly    operating mode      Jolly    operating mode   With the    Jolly    operating mode  the CH150  chronothermostat interrupts the current oper   ating mode and adjusts the operation of the  heating or cooling system to keep the    Jolly     temperature during the entire time set  1 hour  to 99 days and 23 hours  by 1 hour incre   ments   After this time     which is displayed like  a countdown     has elapsed  the previous oper   ation of the chronothermostat will be resumed   To select    Jolly     press JOLLY                                         i Paanan   22 8 TI  08d   ene    in 83 minnannona  a20 m 53  205  M i  M  wH  pu I  par gg    M wH Il  g gg  B ae E ROE lon      unm 4   one  or    len   es   cE   GP O co ees ce oes O oe               The    Jolly    temperature value and the operat   ing mode duration can be modified by means  of the rotary selectors located on the right side  of the chronothermostat     Use the lower rotary selector to modify the  temperature level    The temperature can be modified from 2  C to  40   C  by 0 1   C increments        22  23  24    MIUN                  To set the    Jolly    operating mode duration  i e   hours    h     use the central rotary selector   The hours can range from 0 to 23                          22 23  24 22 201 24  tril   Sh  one 5 0    Sl plea  5 2  NOU          Le  Me  fijres    
9. 0        Relative humidity displaying    20    90        Maximum temperature    T45          Local signalling       LCD display                         Lecalcunnels butions Srolarysalectors The CH150 chronothermostat device conforms  to the following standards    Dimensions  L x H x D  155 x 91 x 20   Separate temperature probe   10 m max CEI EN 60730 1 and seconds parts   distance R amp TTE EN 300 220 3    Reference temperature gra   4 K h   dient     The range data may vary depending on the   Radio signal features 868 350 MHz  lt   15mW ambient conditions    Pern foe S Fantini Cosmi S p A  reserve the right to make             any necessary technical and construction  modifications without giving advance notice     GB79305A    FANTINI COSMI S P A   VIA DELL   OSIO 6  20090 CALEPPIO DI SETTALA  MI   ITALIA  Phone no   39 02 95682 222  Fax no   39 02 95307006  E mail  export fantinicosmi it  Web  www fantinicosmi it    28    
10. 11    To set the    Jolly    operating mode duration  i e   days    d     use the upper rotary selector  The  days can range from 0 to 99                          22 20 1 24  flo 22 201 24  m I E b  LI L fi a     IShil  lt  lt  Gh  eed  6 7   eed  6 7  Ai  SES          You can interrupt the    Jolly    mode at any time   by selecting any other operating mode     The    Jolly    operating mode can be used  for  instance  to    e save energy by lowering the temperature  when the house is not inhabited at the week   ends or winter vacation  while being sure that  a comfortable temperature will exist when the  house is inhabited again     e extend the night heating or cooling beyond  the usual time  i e  when you stay up in the  company of your guests        OFF    function  The    OFF    function can be activated by press   ing OFF     Winter operation                                            Wangan 200  sell      ae a   in ag sun 05 0  05 0 i Fh  D ov Lt  wf L M  ie  5 9 cu  ha S ao aa r D ho O fin  ony ow Mi ese  Las D  o Mie  CD D   ES D  Q   Docc O CO  Z          The chronothermostat adjusts the operation  of the heating system to keep the    Antifreeze     temperature  in order to reduce the energy  consumption and  at the same time  avoid any  damage caused by extremely low tempera   tures     The    Antifreeze    temperature can be modified  from 2  C to 7  C  by 0 1  C increments   by us   ing the lower rotary selector  If a temperature  of less than 2  C is set  the s
11. aced  within 15 days  the chronothermostat will be  automatically turned off and the    OFF    mes   sage will appear on the display instead of the  temperature    The settings and data are kept in the non vol   atile memory     To remote the chronothermostat from its sock   et  proceed as follows    e remove the telephone actuator jack connec   tor  if any     e pull the chronothermostat on its left and right  sides  without applying force to the selectors   If only the    OFF    message appears on the dis   play when the batteries haven been replaced   press the round button  button 5  after the  chronothermostat has been fitted back to the  socket        Important  The standard battery service life  is more than 1 year  It is recommended that  the batteries should be replaced at the start of  the system operation season  to prevent the  batteries from running out when you are away  from home  e g  during the summer or Christ   mas holidays    The batteries must be properly disposed of in  Special containers              Installation   Warning  The unit must be installed only by  qualified personnel  in compliance with the law  regulations in force                 The chronothermostat installation involves the  following operations    e Installing the batteries   e Configuring the chronothermostat param   eters   e Registering the chronothermostat with the  radio actuators   e Fastening the socket to the wall   e Making the electric connections   e Securing the chronothermo
12. ating mode   It is highlighted by the icon placed above     Indications  3 4 5    HHR        LUL l mmn UL T    Air i  P i  j j UL om Ht    POCUCOCULULULULUULULUL ULL UL ULL  a  68 88 0 Te EE st    16     h 4  i C0  hats S64  13 12 1 10   15   t             1  Time   2  Temperature profile   3  Temperature value T1 or    Jolly    operating  mode duration  days    4  Temperature value T2 or    Jolly    operating  mode duration  hours    5  Temperature value T3   6  System ON in Summer operation   7  System ON in Winter operation   8  Relative humidity percentage   9  Perceived temperature  displayed by the  degree    10  Ambient external temperature   11  Current day  1   Monday     7   Sunday   8   Holiday    12  Winter operation   13  Summer operation   14  Battery charge level   15  Humidistat enable   16  Humidistat ON    User manual    To operate the chronothermostat after it has  been installed  proceed as follows    1  Set the date and time    2  Select the Summer Winter operation    3  Select the operating mode     Setting the date and time   To set the current time and date  proceed as  follows    1  Enter the programming menu main page   The operating mode currently used will be in   terrupted temporarily  Choose the time setting  function           ATTU a       vm    i S00 T    4B   D Cu  a         CE  afk    7  AY fF          CW S SEES          in 7  ki Ez  aa   au     B 0  lem                 2  Modify the hour setting by means of the A  and V buttons  then go to t
13. crew                                 temperature    Connecting  probe  Connect the two separate temperature probe  wires with screw clamps A and B  as illustrated  in the figure     the separate       KRBTZ3       26    Connecting the telephone actuator  Connect the three telephone actuator wires  with screw clamps 1  2 and 3  as illustrated in  the figure    Alternatively  the actuator can be connected  through the 3 5 mm jack connector located on  the left side        a gt  m    After the connections have been made  fit the  protection guard back into position     CTx TERMINAL BLOCK       SEPARATE  TEMPERATURE  PROBE    CH150 TERMINAL  BLOCK    Securing the chronothermostat to the  socket   Manually press the chronothermostat to fit  the same to the socket  making sure that the  multi pole connector is correctly inserted  The  chronothermostat clicks into position     27    Technical features       Power supply    2 AA alkaline batteries   1 5 V        Battery life    More than 1 year       Inputs    Telephone actuator  Separate temperature probe       Electric connections    Screw clamps  3 5 mm two pole jack  connector       Insulation    Degree of protection    Double type  2   IP20  pollution degree 2        Setting memorization    Non volatile memory       Microdisconnection    1BU       Software    Class A       Temperature  range    adjustment    2  C     40  C       Antifreeze temperature ad   justment range    2  C  7  C       Humidity adjustment range    30      7
14. ermostat  to  be informed about the ambient temperature or  the heating   cooling system status    e remotely manage the chronothermostat op   erating modes     The chronothermostat comes in three colours   white  silver  CH151RF series  and anthracite  black  CH152RF series      Controls and indications    Controls                                i 11   ALRINTEININTETATETNINIETATET NINTE ETET NINIS TEI  zag 1 0   E a8 9   i we OO    8   AG OE DA 7  saeajeac   Oc c3          1  Button used to select the    Manual    operating  mode or increase a value  A      2  Button used to select the    Automatic    oper   ating mode or decrease a value  V       3  Button used to select the    Holiday    operat   ing mode or go back to the previous data item    lt 4     4  Button used to select the    Jolly    operating  mode or go to the next data item   gt        5  Button used for the    OFF    or    Enter    func   tions     6  Button used for the    Programming    or    Copy     or    Statistical data displaying    functions      7  Rotary selector for temperature correction   T1  Manual temperature  Jolly temperature   and   Antifreeze temperature     8  Rotary selector for correcting temperature  T2 or the Jolly operating mode duration     9  Rotary selector for correcting temperature  T3 or the Jolly operating mode duration   10  Summer Winter switching button   11  Chronothermostat reset button      The function associated with the button or se   lector depends on the current oper
15. eviously used                 Setting the desired humidity level   The CH150RF 151RF 152RF chronothermo   stat allows you to actuate a humidistat by set   ting the desired humidity value  To be able to  actuate a humidistat  it is requested that this  function will be enabled through the technical  menu  refer to the  lt  lt Chronothermostat config   uration gt  gt  chapter   To set the desired humidity  value  proceed as follows     1  Enter the programming menu main page   The operating mode currently used will be in   terrupted temporarily  Choose the time table  setting function           ujil c    Au    ILIE z    orgenan eg  EH  13 0  7  n         m   20h                SETIPI                         2  Use the    button to move and highlight the  set humidity value        3 05 0 CE Ee L   t  fe JY JS JEP JL     Se O S amp D                      3  Modify this value by pressing the A and V  buttons until the desired value is displayed   Press ENTER to go back to the programming  menu main page     4  Press ENTER again to exit the programming  menu  The chronothermostat operating mode  previously interrupted will be resumed                 8   LIS    50                               SSS a a an       Maintenance   The chronothermostat can be cleaned by us   ing a soft cotton cloth  no detergent must be  used      Replacing the batteries   When the battery charge level starts to read  low  the     gt  symbol will start blinking on  the display  If the batteries are not repl
16. he chronothermostat will normally send a  radio control every minute  During the normal  Operation  some radio signals might be lost  due to external disturbance  in any case  such  disturbance will  provided it does not often oc     cur in time  not affect the correct equipment  operation     Fastening the socket   The chronothermostat is supplied complete   with a socket suitable for fitting both to a wall   and to rectangular built in cases  either of the   3 seat or round types    83    60       pasos  panong    i    s     I    DRILLING CENTRE DISTANCES    25    Separate the socket from the chronothermo   stat by levering on the slot found at the socket  bottom by using a suitable tool     Make sure that the socket is properly secured  and is not deformed  Verify that the chrono   thermostat connection multi pole connector is  found at the left bottom corner     To ensure correct operation of the socket  the  latter should be positioned approximately 1 5  m above the floor level  far from heat sources   heating radiators  direct sunshine  etc    doors  and windows     The distance between the chronothermostat  and the radio actuators shall not exceed 30  m  indoors  and 70 m  outdoors    N B  The  range data may vary depending on the ambi   ent conditions   Avoid screening the devices by  using metal components     Electric connections   Prior to making the connections  remove the  terminal protection guard  the latter shall  be kept together with the fastening crossed  s
17. he minute setting  by means of the    button                       SIV Ie IP IR ICS    Goma    co  ne pim                      3  Modify the minute setting by means of the  A and Y buttons  then go to the day setting  by means of the    gt  button                 ak          rn    rr    Z 370 cree    1 al VI lha kb  DOODS 1 a a    a   Se i     jme                            4  Modify the day setting by means of the A  button  then press ENTER to go back to the  main page of the programming menu                    702  CO 4 ae CGL  wite E JC 0  CIM IK JP JEJE   4 Tas ia Je Jer JE                          5  Press ENTER again to exit the programming  menu  The chronothermostat operating mode  previously interrupted will be resumed           fu ji he   wine ig  wun   mnn   on m T e g   Ou  er    2      dads me    bs                         ry     I j   rl EOR               Summer Winter selection    To shift from the Summer opera   tion  heating system  to the Sum   mer operation  cooling system    and vice versa  keep the Sum   mer Winter button depressed for  at least 4 seconds  The selected  operation will be shown on the  display by means of the    Winter     or    Summer    icons     02            Winter Summer mie  A                   Operating modes   The CH150 151 152 chronothermostat fea   tures four different operating modes  Manual   Automatic  Holiday and Jolly  in addition to the  OFF function         Manual    operating mode   With the Manual operating mode  the ch
18. ici vecnccncvemsactbnecvdanatienccvannwes 23  Fastening the socket             cccccssssceeeeesesseeeeeees 25  Electric connections cee cecdeeececttte eee cerca 26    Securing the chronothermostat to the socket   27    Technical features              ccceccecececceececcecceceeeaeceeeess 27    Introduction    The CH150RF 151RF 152RF chronothermo   stat measures the ambient temperature and  controls the heating  conditioning  system  through a radio connection with an actuator   A humidistat can also be driven  The operat   ing mode can be either chosen from among  the preset ones or customized to one   s own  needs    The large display shows the temperature pro   file     i e  the relationship between the time ta   ble and the temperature to be kept     as well as  the measured temperature  relative humidity   calculated perceived temperature  time and  day of the week    The chronothermostat is battery powered   Both the settings and the data are stored ina  non volatile memory capable of keeping them  even when the batteries are down     The following external interfaces are available  for the CH150RF chronothermostat    e Radio actuator   e Separate temperature probe   e Telephone actuator for fixed telephone lines   which makes it possible to perform remote    control through the DTMF keypad  multi tone   e Telephone actuator with GSM modem  used  for remote control by means of SMS mes   sages     Both telephone actuators allow you to    e remotely interrogate the chronoth
19. into the  memory    If no button is pressed within 3 minutes  the  chronothermostat will exit the configuration  program and the operating mode previously  used will be resumed  without saving    To eliminate the modifications made and  resume the preset configuration parameter  values  keep the A  button 1  and VW  button 2   buttons depressed simultaneously for approxi   mately 4 seconds                                                     In    Parameter Writing Values Preset   dex value  Type of con  COn rEL  rAd         None  nected card   2 Heating actuator  rF t           registration radio  control   3 Humidity adjust    rH ON OFF OFF  ment enable   3A   Humidification rF rH           actuator registra   tion radio control   4 Temperature CELS    C   F   C  scale or FHAr   5 Type of Std or   Std   ProP Std  adjustment ProP   5A   Thermal DIFF HI   LO LO  differential   5A  Adjustment band   bAnd 1   C  4  C 2  C    step 0 1  C    5B   Adjustment PEr 5   10 7 20 10  period minutes minutes   6 Separate SEct       FLO   In       temperature   Out  probe  configuration   6A   Floor tFLO 15   C     27 0   C  temperature limit 45  C                            In    Parameter Writing Values Preset  dex value  7 Ambient tem  Corr  4 0   C to  0 0  C   perature  4 0  C  correction  8 Optimization OPt ON OFF OFF  8A ___  Optimization OPtH 1h     5h 2h  max  duration   hours   9 Pump antiscuff Pu ON OFF OFF  10 Software version   SOFt XXX XXX       and radio  address             
20. oP   This  parameter is used only for heating     Thermal differential   It sets the thermal differential value to be used  when the differential temperature adjustment  mode is selected  By properly choosing the dif   ferential  on the basis of the thermal inertia of  the heating system  continuous switch on and  switch off will be avoided  It is recommended  that the low thermal differential  LO  should be  used for the heating systems equipped with ra   diators  and the high thermal differential  HI   should be used for the systems equipped with  fan coils     21    Adjustment band   It sets the adjustment band when the propor   tional temperature adjustment mode is chosen   Select an appropriate value on the basis of the  system   s temperature gradient  wide band for  very high gradients  narrow band for low gra   dients      Adjustment period   It sets the adjustment cycle duration  switch   on   switch off period  when the proportional  temperature adjustment mode is chosen  Se   lect 5 minutes for low inertia systems  fan coil  type   10 minutes for average inertia systems   aluminium radiator type  and 20 minutes for  high inertia systems  cast iron radiator type      Separate temperature probe configuration  A separate temperature probe can be connect   ed to the chronothermostat  the operation of  such probe is determined by this parameter     e Probe OFF        the temperature value de   tected by the probe  even if the latter is con   nected  will not be used    
21. off           22   23  24 ipa                   p gt    pm  free  df       Temperature T2 cannot be higher than tem   perature T3 or lower than temperature T1        22   23   24 22   23  24      feed Wb   eed  oF 3 E   PE  it  al   oe id TT eee                               Temperature T1 cannot be higher than tem   perature T2 or lower than 2   C        22 23  24 22   23  24    We   ec We   ec  Ine ano  hit  ot mit  at   JO faa 08  6 0                If no customization has been made  the au   tomatic operating mode will function with the  stored temperature profiles  i e  the preset  ones  refer to   Preset programs     To custom   ize the profiles  refer to   Chronothermostat  programming          Holiday    operating mode   With the    Holiday    operating mode  the CH150  chronothermostat CH150 adjusts the opera   tion of the heating or cooling system by fol   lowing one single temperature profile  which  is valid for all days  To select    Holiday     press  HOLIDAY        f     I a i jin     ree    90 i   nanny eg  ery  Ta ae 7    53   meg ear  Wp  mM wH Ob    1 en  uw    inn  171 9 53    me eh          DAY a    o a  u  lam     an 43   er  ow     nm  on     oe ase M lass      vr      em     co 7P O                   CD CD CD CD  O CD             To modify the temperature levels  refer to  the description of the    Automatic    operating  mode    When the preset programs are used  refer to    Preset programs     the    Holiday    mode will  follow the profile envisaged
22. rono   thermostat adjusts the operation of the heating  or cooling system in order to always keep the  same temperature  To select    Manual     press  MAN                                           Penton 3i   miaa   mi i       g 33 ddd 20 8  oS E a CHS   SLI CILID   CALLS COL ID      jc SSeS O CD       The temperature level can be modified during  operation by means of the lower rotary selec   tor located on the right side of the chronother   mostat  The temperature can be changed from  2  C to 40   C by 0 1  C increments        22   23  24 22   23   24    UNN o  MINN 220                         Automatic    operating mode   With the    Automatic    operating mode  the  chronothermostat adjusts the operation of the  heating or cooling system by following the pro   files defined for the various days of the week   To select    Automatic     press AUTO                                                    f r Yada 20 0 ul ninnaa     28 8  m pij i       k Ftd sa m in   11   ay fit    1 48 m   C 4a  a bi C i LS  i M owe a ef  ARSOLI  ES a5  LILIS  C pi co O c   Docea O          The three temperature levels used can be  modified during operation by means of the ro   tary selectors located on the right side of the  chronothermostat     Temperature T3 cannot be lower than tem   perature T2 or higher than 40   C    During Summer operation  temperature  T3 features an upper limit of 30  C  When this  value is exceeded  T3 will take the OFF value   which will involve switching the system 
23. starting from  step 2 for the other days of the week  the    Holi   day    profile will be indicated as DAY 8   To go  back to the programming menu main page  use  the ENTER button to scroll through the eight  days or keep the ENTER button depressed for  3 seconds     If no button is pressed within the next three  minutes  the chronothermostat operating mode  previously used will be resumed     Preset parameter reset   To resume the preset temperature profiles and  values  11 T2 T3 Temperature used with the  Manual mode  Temperature used with the Jolly  mode  Antifreeze temperature  OFF function    keep the A and YW buttons depressed simulta   neously when you are in the temperature pro   file programming mode     Displaying the temperature detected by  the separate probe   To display the temperature detected by the  separate probe  only if the latter has been con   figured as an external probe or floor mounted  probe   the chronothermostat must be config   ured  refer to  lt  lt chronothermostat configura   tion gt  gt   and the probe must be connected    To display the temperature value read by the  separate probe  press the button of the operat   ing mode currently used  the temperature will  blink   To display again the temperature detect   ed by the chronothermostat  press again the  button of the operating mode currently used   the temperature will not blink any longer      Statistical data   The CH150 chronothermostat provides a set of  statistical data concerning the 
24. stat onto the  socket     Installing the batteries   Separate the socket from the chronothermo   stat by levering on the slot found at the socket  bottom by using a suitable tool  Insert two  long life AA alkaline batteries  1 5 V  into the  chronothermostat rear  observe the correct po   larity   After installing the batteries  the chrono   thermostat will turn on automatically  Fasten  the socket back again  making sure that the  multi pole connector is inserted correctly  The  chronothermostat will click into position     Configuring the chronothermostat       arning  The chronothermostat must be con   igured only by qualified personnel           By configuring the chronothermostat  the de   vice operation parameters can be customized   To access the configuration program  proceed  as follows    1  Press the SET   PROG button  button 6    The operating mode currently used will be tem   porarily interrupted and will be automatically  resumed at the end of programming    2  Keep the SUMMER   WINTER switching  button  button 10  depressed for approximately  5 seconds     Each configuration parameter  which features  its own preset settings  is identified on the dis   play by an index and a writing  To modify the  parameter values  use the A  button 1  and V   button 2  buttons  To move across the param   eters  use the  gt   button 4  button     To go back to the initial page of the program   ming menu  press the ENTER  button 5  but   ton  which will store the modifications 
25. system opera   tion  To access this data  proceed as follows     1  Enter the programming menu main page   The operating mode currently used will be  interrupted temporarily  Choose the statistical  data function           sanana    28 8  wn     19 0  We eneneuealeaoaaa we  12          o    cut    M ow  OM a i  R      D E   aw     e 0  E       a        es oes os oes O  Sa    n a a E O  Si       im  3  mr  rr           oJ 9                            2  Page 1  number of    hours during which the  system was operated  on the previous day  6  hours in the image      Use the  gt  button to go    to the next page                       3  Page 2  total number    of hours during which  the system has been  switched on and operat   ing since its first start up    2       2 Q   16 hours in the image                        Use the  gt  button to go to the next page   Press the A and VW buttons simultaneously to  reset the total system switch on hours     4 Page 3  minimum  temperature reached  on the current day   and time at which such   J  I  minimum temperature cocca O Cc  was reached  15 8  C   at 03 15 a m  in the im    age   Use the    gt  button   to go to the next page                          5  Page 4  maximum   temperature reached 2108 GH    on the current day  and     m5 EA  ae ao  time at which such maxi  a LIE Es  mum temperature was    2                reached  22 5  C at 09 08   p m  in the image      6  Press the ENTER button twice to go back to  the operating mode pr
26. ystem will be fully  turned off and the antifreeze protection will be  lost              22   23  24    22  23  24    Onde oo     ee o25                   Summer epee          iaoea 28 0 j   f   pi w i vm hunn Seg     p      nann   a 24 8   1      atoni  12 06 aa eee 2  Te 42    amp  pay 2 L I      30    E  DAY Er I  pE a  fom  un lacs   nus D  or      om CO             DFF           a                D   GD CD CD  O om                 The system will be fully turned off and the     OFF    message will appear on the display   without any temperature profile     Preset programs   The CH150 chronothermostat features two  preset programs  i e     Winter    and    Summer         for quicker start up        Winter    program     working days  Mon   days porous  Friday  pu i jeg       pLa pata  CCIC    sta       Winter    program     public holidays  Satur   days  Sundays ane    Holiday    program   eT 20         4005  ECCI                                        Summer    program  All days of the week    plus    Holiday    program    mh peun i i 1 cog  26 0  PH    M                      Chronothermostat programming   You can customize the temperature profiles for  the    Automatic    and    Holiday    operating modes   so as to adapt them to your own needs  To set  new temperature profiles  proceed as follows     1  Enter the programming menu main page   The operating mode currently used will be in   terrupted temporarily  Choose the temperature  profile customization function      
    