1. FRENIC VG Instruction Manual The materials are subject to change without notice Be sure to obtain the latest editions for use e Read through this instruction manual to become familiar with this product before proceeding with installation connections wiring operation or maintenance and inspection e Improper handling might result in incorrect operation a short life or even a failure of this product as well as the motor e Deliver this manual to the end user of this product Keep this manual in a safe place until this product is discarded E Safety precautions Read this manual thoroughly before proceeding with installation connections wiring operation or maintenance and inspection Ensure you have sound knowledge of the device and familiarize yourself with all safety information and precautions before proceeding to operate the inverter Safety precautions are classified into the following two categories in this manual Failure to heed the information indicated by this symbol may lead to dangerous A WARNING conditions possibly resulting in death or serious bodily injuries Failure to heed the information indicated by this symbol may lead to dangerous A CAUTION conditions possibly resulting in minor or light bodily injuries and or substantial property damage Failure to heed the information contained under the CAUTION title can also result in serious consequences These safety precautions are of ut
2. Mount the interface card so that connector CN1 on the card comes to be connected to connector B port on the control PCB 3 Secure the interface card with three attached screws e 4 Connect the power cable from the option to CN24 on the Control PCB 5 Mount the front cover in the reverse order of removal referring to Figure 2 1 1 or 2 1 2 Interface card Figure 2 2 1 Mounting the Interface Card when connecting to B port E Mounting procedure 2 With the digital 16 bit option A CAUTION Spacers that come with this interface card and the ones that come with the digital 16 bit option are different slightly in length Make a distinction between them referring to the figure below Wrong use may break the product z Spacer that comes with Spacer that comes with this interface card the digital 16 bit option U U Unit mm 1 Mount the digital 16 bit option onto connector D port provided on the control PCB 2 Secure the digital 16 bit option with two screws a that come with the option through holes and then set four spacers b that come with the option into holes to 3 Set spacer d that comes with this interface card onto location c of the option mount provided on the control PCB 4 Mount the interface card so that connector CN1 on the card comes to be connected to connector B port on the control PCB 5 Secure the interface card with three attached
3. FO Instruction Manual Expansion DIO Card for FRENIC VG OPC VG1 DIO Thank you for purchasing our expansion DIO card designed for the high performance vector control FRENIC VG series of inverters Improper handling might result in incorrect operation a short life or even a failure of this product Deliver this manual to the end user of this product Keep this manual in a safe place until this product is discarded This manual does not contain the description of function codes or troubleshooting information Read through this manual in conjunction with the FRENIC VG User s Manual Fuji Electric Co Ltd INR SI47 1604JE Preface Thank you for purchasing our expansion DIO card OPC VG1 DIO This interface card can be connected to A or B port of option connection ports on the FRENIC VG This instruction manual does not contain the description of function codes troubleshooting information or handling instructions of the inverter Read through this manual in conjunction with the FRENIC VG Instruction Manual and User s Manual to become familiar with proper handling and operation Improper handling might result in incorrect operation a short life or even a failure of the interface card Keep this manual in a safe place Related Publications Listed below are the other materials related to the use of the expansion DIO card OPC VG1 DIO Read them in conjunction with this manual as necessary FRENIC VG User s Manual
4. al procedure differs depending on the inverter type capacity FRN22VG1S 2J 4J 22 kW or lower types FRN30VG1S 2J 4J 30 kW or upper types As shown in Figure 2 1 1 loosen the cover mounting screw on section a and pull out the upper end of the front cover towards you Figure 2 1 1 Removing the Front Cover 1 As shown in Figure 2 1 2 remove the cover mounting screws the number of screws differs depending on the inverter capacity on section b and remove the front cover 2 Open the keypad enclosure Keypad enclosure Control printed circuit board Control PCB Figure 2 1 2 Removing the Front Cover FRN22VG1S 2J 4J 22 kW or lower types FRN30VG1S 2J 4J 30 kW or upper types 2 2 Installing the Interface Card The interface card should be connected to either one of two connectors A port upper side and B port lower side on the control printed circuit board control PCB When using the interface card without the digital 16 bit option e g OPC VG1 UPAC follow the Mounting procedure 1 given below When using the interface card with the digital 16 bit option e g OPC VG1 UPAC follow the Mounting procedure 2 given below Note Two interface cards cannot be used on an inverter E Mounting procedure 1 Without the digital 16 bit option 1 Set three attached spacers d onto three locations a to c of the option mount provided on the control PCB 2
5. ever modify the interface card Otherwise an electric shock or injuries could occur Disposal A CAUTION e Treat the interface card as an industrial waste when disposing of it Otherwise injuries could occur Others ACAUTION e Never modify the interface card Doing so could cause an electric shock or injuries Chaper 1 BEFORE USE 1 1 Acceptance Inspection A CAUTION e Do not use the product that is damaged or lacking parts Otherwise injuries could occur Unpack the package and check the following 1 The product is the type you ordered You can check the model printed on the interface card Model OPC VG1 DIO 2 The interface card is not damaged during transportation 3 The following accessories are also contained in the package Three screws M3 Three spacers One plug One connector cover If you suspect the product is not working properly or if you have any questions about your product contact the shop where you bought the product or your local Fuji branch office 1 2 External Appearance Figure 1 2 1 External Appearance 1 3 Precautions for Use 1 3 1 Temporary storage Table 1 3 1 Storage and Transport Environments Item Specifications Storage temperature 25 to 70 C Places not subjected to abrupt temperature changes or condensation Note 1 or freezing Relative humidity 5to 95 Note 2 The interface card must not be e
6. ht result e Incorrect handling in installation removal jobs could cause a failure A failure might result Operation A WARNING e Be sure to mount the front cover before turning the power ON Do not remove the cover when the inverter power is ON Otherwise an electric shock could occur e Do not operate switches with wet hands Doing so could cause an electric shock e If you configure the function codes wrongly or without completely understanding the FRENIC VG Instruction Manual and User s Manual the motor may rotate with a torque or at a speed not permitted for the machine Confirm and adjust the setting of the function codes before running the inverter Otherwise an accident could occur Maintenance and inspection and parts replacement A WARNING A e Before proceeding to the maintenance inspection jobs turn OFF the power and wait at least five minutes for inverters of 22 kW or below or at least ten minutes for those of 30 kW or above Make sure that the LED monitor and charging lamp are turned OFF Further make sure using a multimeter or a similar instrument that the DC link bus voltage between the terminals P and N has dropped to the safe level 25 VDC or below Otherwise an electric shock could occur e Maintenance inspection and parts replacement should be made only by qualified persons e Take off the watch rings and other metallic objects before starting work e Use insulated tools e N
7. in 70 If the inverter equipped with the interface card has been installed to the equipment or panel at construction sites where it may be subjected to humidity dust or dirt then temporarily remove the inverter and store it in the environment specified in Table 1 3 1 1 3 3 Wiring precautions 1 2 Route the wiring of the control circuit terminals as far from the wiring of the main circuit as possible Otherwise electric noise may cause malfunctions Fix the control circuit wires inside the inverter to keep them away from the live parts of the main circuit such as the terminal block of the main circuit Chaper 2 INSTALLING THE INTERFACE CARD 2 1 Removing the Front Cover A CAUTION equipment for prevention of electric shock e Incorrect handling in installation removal jobs could result in a broken produce e Before installing or removing the interface card shut down the input power to the inverter and make sure that the charging lamp is turned OFF Even if all of the input power to the main circuit and control circuit and the auxiliary power are shut down however power is still applied to the inverter control terminals 30A 30B 30C Y5A and Y5B when the external control circuit is supplied with power from a separate power supply Shut down the power of the external equipment for prevention of electric shock Shut down the power of the external Remove the front cover from the inverter as shown below The remov
8. most importance and must be observed at all times Installation and wiring A WARNING A e Before starting installation and wiring turn OFF the power and wait at least five minutes for inverters of 22 kW or below or at least ten minutes for those of 30 kW or above Make sure that the LED monitor and charging lamp are turned OFF Further make sure using a multimeter or a similar instrument that the DC link bus voltage between the terminals P and N has dropped to the safe level 25 VDC or below Qualified electricians should carry out wiring Otherwise an electric shock could occur In general sheaths of the control signal wires are not specifically designed to withstand a high voltage i e reinforced insulation is not applied Therefore if a control signal wire comes into direct contact with a live conductor of the main circuit the insulation of the sheath might break down which would expose the signal wire to a high voltage of the main circuit Make sure that the control signal wires will not come into contact with live conductors of the main circuit Doing so could cause an accident or an electric shock Do not use the product that is damaged or lacking parts Doing so could cause a fire an accident or injuries A CAUTION e Prevent lint paper fibers sawdust dust metallic chips or other foreign materials from getting into the inverter and the interface card Otherwise a fire or an accident mig
9. screws e 6 Connect the power cable from the option to CN24 on the Control PCB 7 Mount the front cover in the reverse order of removal referring to Figure 2 1 1 or 2 1 2 Control PCB Power cable e Figure 2 2 2 Mounting the Interface Card when connecting to B port History of revision Number Date of revision Remarks November 2011 First edition Copyright 2011 Fuji Electric Co Ltd No part of this publication may be reproduced or copied without prior written permission from Fuji Electric Co Ltd All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders The information contained herein is subject to change without prior notice for improvement The purpose of this instruction manual is to provide accurate information in handling setting up and operating of the DIO interface card Please feel free to send your comments regarding any errors or omissions you may have found or any suggestions you may have for generally improving the manual In no event will Fuji Electric Co Ltd be liable for any direct or indirect damages resulting from the application of the information in this manual A Fuji Electric Co Ltd Gate City Ohsaki East Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan Phone 81 3 5435 7058 Fax 81 3 5435 7420 URL http www fujielectric com E 2011 11
10. xposed to dust direct sunlight corrosive or flammable Atmosphere gases oil mist vapor water drops or vibration The atmosphere must contain only a low level of salt 0 01 mg cm or less per year Atmospheric 86 to 106 kPa during storage pressure 70 to 106 kPa during transportation Note 1 Assuming comparatively short time storage e g during transportation or the like Note 2 Even if the humidity is within the specified requirements avoid such places where the interface card will be subjected to sudden changes in temperature that will cause condensation to form Precautions for temporary storage 1 2 3 Do not leave the interface card directly on the floor If the environment does not satisfy the specified requirements listed in Table 1 3 1 wrap the interface card in an airtight vinyl sheet or the like for storage If the interface card is to be stored in a high humidity environment put a drying agent such as silica gel in the airtight package 1 3 2 Long term storage The long term storage method of the interface card varies largely according to the environment of the storage site General storage methods are described below 1 2 3 The storage site must satisfy the requirements specified for temporary storage The package must be airtight to protect the interface card from moisture Add a drying agent inside the package to maintain the relative humidity inside the package with
Download Pdf Manuals
Related Search
Related Contents
User's Manual - Glunz & Jensen Guide d`évaluation des capacités parentales_25-09 Milwaukee 2101-21 Use and Care Manual Origin Storage 146SAS/15-S5 EUROLITE N-18 User Manual Service Documentation - Andi - Microgate 取扱説明書(PDF) Range Rover 2000 Manual do proprietário - 2a edição - Por Copyright © All rights reserved.