Home
skyrc-4B6AC说明书(U1B6M10111 ).cdr
Contents
1. 3 0V cell LiPo LiIon 3 6V cell 4 1V cell 2 5V cell 1C 3 3V cell 3 6V cell 3 3V cell 4C 2 0V cell LiFe 1 2V cell 1 5V cell n a 1C 2C 0 85V cell NiCd 1 2V cell 1 5V cell n a 1C 2C 1 0V cell MiMH 2 0V cell 2 46V cell n a 0 4C 1 75V cell Pb WARNING AND SAFETY NOTES Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by charge time The maximum permissible charge current varies depending on the battery type or its performance and can be found in the information by the battery manufacturer Only batteries that are expressly stated to be capable of quick charge are allowed to be charged at rates higher than the standard charge current Connect the battery to the terminal of the charger red is positive and black is negative Due to the difference between resistance of cable and connector the charger can not detect resistance of the battery pack the essential requirement for the charger to work properly is that the charge lead should be of adequate conductor cross section and high quality connectors which are normally gold plated should be fitted to both ends Always refer to the manual by the battery manufacturer pertaining to charging methods Operate according to their recommended charging current and charging time Lithium batt
2. EU UK AU CHN Version DC Input Charger circuit power Charge current range Discharge current range Current drain for balancing port NiCd NiMH battery cell count LiPo LiFe Lilon cell count Pb battery voltage Net weight Dimension 1 2 3 4 5 6 7 8 9 10 11 6 Tamiya charging cable 7 Futaba RX charging cable 8 JST BEC charging cable 9 18AWG wire charging cable 10 TP FP Adaptor 11 XH Adaptor 1 AC Power Cord 2 DC Power Input Cable 3 SKYRC QUATTRO B6AC 4 Plug in battery clamps 5 Crocodile clip charging cable 100 120V 380 330W 220 240V 380 330W 11 18Volt 4 x 50W 200W 0 1 6 0A 0 1 1 0A 300mA cell 1 15Cells 1 6Cells 2 20V 1 57kg 225x170x66mm RECOMMENDED ACCESSORIES TP FP Adaptor Temperature Sensor Cable Software Kit EH Adaptor XH Adaptor HP PQ Adaptor 18AWG charging cable Dean charging cable Tamiya charging cable TRAXXAS charging cable Glow charging cable Bullet charging cable Ec3 charging cable Crocodile clip charging cable Futaba RX charging cable CONFORMITY DECLARATION CONFORMITY DECLARATION Conform Conform Conform Conform CE LVD CE EMC EN60335 FCC VOC FCC Part 15B WARRANTY AND SERVICE We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase The warranty only applies to material or operational defects wh
3. 3 7 22 2V This displays the number of cells you set up and the processor detects R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen If both numbers are identical you can start charging by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead This screen shows the real time status during charge process Press BATT TYPE STOP key once to stop the charge process This function is for balancing the voltage of Lithium polymer battery cells while charging In the balance mode the battery needs to have a balance lead to connect to the individual balance port at the right side of the charger And you need to connect the battery s power lead to the output of charger Charging in this mode is different from the normal mode The built in processor monitors the voltage of individual cells and controls the input current fed into each cell to equalized voltage gt 3 seconds FAST CHARGING OF LITHIUM BATTERY FAST CHARGING OF LITHIUM BATTERY CHARGING LITHIUM BATTERY IN THE FAST CHARGE MODE LiPo FAST CHG 2 0A 11 1V 3S INC DEC INC DEC Batt type Stop Start Enter Start Enter R 3SER S 3SER CONFIRM ENTER Li3s 2 0A 12 59V FAS 022 43 00682 Number of cells Charging time Charging current Current voltage battery
4. It is said that NiCd and NiMH batteries are suffering from memory effect NiCd has more memory effect than NiMH Lithium batteries are recommended to be discharged partially rather than fully Frequent full discharging should be avoided if possible Instead charge the battery more often or use a battery of larger capacity Full capacity cannot be reached until it has been subjected to 10 or more charge cycles The cyclic process of charge and discharge will optimize the capacity of battery pack PROGRAM FLOW CHART PROGRAM FLOW CHART LITHIUM POLYMER BALANCE CHARGE PROGRAM CONNECTION DIAGRAM CONNECTING THE CHARGER CONNECTING THE BATTERY Balance socket Using terminal clip attaching to car battery The balance wire attached to the battery must be connected to the charger with the black wire aligned with the negative marking Take care to maintain correct polarity See the wiring diagram below This diagram shows the correct way to connect your battery to the SKYRC QUATTRO B6AC while charging in the balance charge program mode only WARNING Failure to connect as shown in this diagram will damage this charger SKYRC QUATTRO B6AC comes with the built in switching power supply You can connect the AC power cord directly to the main AC socket 100 120V AC US Version or 220 240V AC EU Version For attaching directly to 12V car batteries It is critically important that you use a fully charged 13 8V car battery Import
5. in the manual mode it will charge with the current you set You can make it blink in the current field and press INC and DEC simultaneously to swap between Auto and Manual Mode NOTE Allowable fast charge current 1C 2C 4 14 4 16 4 09 2 18 0 00 0 00 gt 3 seconds gt 3 seconds DISCHARGE OF NICD NIMH BATTERY DISCHARGE OF NICD NIMH BATTERY CHARGE DISCHARGE AND DISCHARGE CHARGE CYCLE OF NICD NIMH BATTERY NIMH DISCHARGE 1 0A 11 5A INC DEC INC DEC Batt type Stop Start Enter NIMH 1 0A 7 42V DSC 022 45 00890 Battery type Elapsed time Discharge current Battery voltage Discharged capacity NIMH CYCLE DCHG gt CHG 3 INC DEC INC DEC Batt type Stop Start Enter NIMH 1 0A 7 42V D gt C 022 45 00890 DCHG 1 1314mAh CHG 1 1430mAh Battery type Elapsed time Discharge or charge current Battery voltage Discharged or charged capacity Set charge current on the left and the final voltage on the right Range of the charge current is 0 1 1 0A range of final voltage is 0 1 25 0V Press START ENTER key for more than 3 seconds to start the program The screen indicates the discharging state You can press START ENTER key to alter discharge current Press START ENTER again to store the value Press BATT TYPE STOP key to stop discharging The emitted sound alerts the end of discharging You can set up the sequence on the left and the numbe
6. than 3 seconds to start the process charge current 0 1 6 0A voltage 3 7 22 2V This displays the number of cells you set up and the processor detects R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen If both numbers are identical you can start charging by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead This screen shows the real time status during charge process Press BATT TYPE STOP key once to stop the charge process gt 3 seconds CHARGING LITHIUM BATTERY IN THE CHARGE MODE This charging mode is for charging Li Po Ion Fe battery without balance lead CHARGING LITHIUM BATTERY IN THE BALANCE MODE BALANCE OF LITHIUM BATTERY LiPo BALANCE 2 0A 11 1V 3S INC DEC INC DEC Batt type Stop Start Enter Start Enter R 3SER S 3SER CONFIRM ENTER Li3s 1 2A 12 59V CHG 022 43 00682 Number of cells Charging time Charging current Battery voltage Charged capacity CHARGING LITHIUM BATTERY IN THE BALANCE MODE The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set After setting the current and voltage press START ENTER key for more than 3 seconds to start the process charge current 0 1 6 0A voltage
7. will be terminated automatically when you set the maximum value Temperature threshold The battery s internal chemical reaction will cause the temperature of the battery to rise If the temperature limit is reached the process will be terminated This function is available by connecting optional temperature probe which is not included in the package Processing time limit You can also limit the maximum process time to avoid any possible defect Data store load The maximum five batteries data can be stored for each output 4 5SET You can keep the data pertaining to program setting of the battery of continuous charging or discharging Users can call out these data at any time without any special program setting Cyclic charging discharging 1 to 5 cyclic and continuous process of charge gt discharge or discharge gt charge is operable for battery refreshing and balancing to stimulate the battery s activity PC based analysis uing USB Communication SKYRC QUATTRO B6AC offer PC based program can analysis the characteristic of the battery via USB port It shows a graph of voltage current capacity curves It also shows the individual voltage of each cell in the Lithium battery pack PC LINK USB adaptor can be purchased separately Never attempt to charge or discharge the following types of batteries A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged
8. 0 3 0 1100 11 9 92 minutes 1000mAh 1 2A 1000 1 2 833 11 9 70 minutes Lithium battery LiIon LiPo LiFe program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3 3V 3 6V and 3 7V per cell These batteries need to adopt different charge technique that is termed constant current CC and a constant voltage CV method The charge current varies according to the battery capacity and performance The Lithium battery is charged at a constant current until it reaches the final charge voltage of 4 2 V per cell B After this point the voltage is kept at a constant level and the residual charge takes the form of a declining current curve C until the cut off point D is reached Charge current C 10 At this point the battery can be disconnected from the charger and is ready for use The final voltage of charge process is also very important it should be precisely matched with the charged voltage of the battery They are 4 2V for LiPo 4 1V for Lilo and 3 6V for LiFe The charge current and nominal voltage as for cell count set on the charge program must always be correct for the battery to be charged When you are willing to alter the parameter value in the program press start enter key to make it blink then change the value with Inc gt or lt Dec key The value will be stored by pressing start enter key once 4 2V V A Ah A B C D t V A Ah CHARGING LITHIUM BATT
9. 6AC satisfy all relevant and mandatory EC directives and FCC Part 15 Subpart B 2008 For EC directives The product has been tested to meet the following technical standards For safety of household and similar electrical appliances Electromagnetic compatibility EMC Conduction Emission amp Radiation Emission Conform Conform All specifications and figures are subject to change without notice Manufactured by SKYRC TECHNOLOGY CO LTD www skyrc com C Printed in China 2011 06
10. E BREAK DOWN VOL SELECT ERR INPUT VOL ERR SHORT ERR CONNECTION BREAK BATTERY CHECK HIGH VOLTAGE BATTERY VOLTAGE CELL LOW VOL BATTERY VOLTAGE CELL HIGH VOL BATTERY VOL ERR CELL CONNECT TEMP OVER ERR CONTROL FAILURE Battery connection is interrupted Short circuit of the output termination Input voltage wrong The voltage of the battery pack has been selected incorrectly The processor cannot control the feeding current please repair it The internal temperature is too high please cool it down SKYRC QUATTRO B6AC incorporates a variety of functions for the systems to verify processes and the state of the electronics In case of an error the screen will display the cause of error and emit an audible sound The charger has malfunctioned for some reason Seek professional advice The voltage is lower than which is set Please check the number of cells in the battery pack The voltage is higher than which is set Please check the number of cells in the battery pack Voltage of one cell in the battery pack is too low please check the voltage of each cell Voltage of one cell in the battery pack is too high please check the voltage of each cell Wrong connection of the connector detected please check the connector and cable SPECIFICATION SPECIFICATION THE SET CONTAINS stated values refer to one charger except built in power supply dimension amp weight AC Input US Version
11. ERY IN THE CHARGE MODE Key Beep ON Buzzer ON Input Power Low Cut Off 10 0V Capacity Cut Off ON 5000 mAh INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC LITHIUM LIPO LILON LIFE PROGRAM The program provides maximum capacity protection function If the delta peak voltage cannot be detected or the safe timer times out the charge process will stop automatically when the battery reaches the maximum charge capacity set by the user A beep to confirm users operation sounds every time a button is pressed A beep or melody sounds at various times during operation to confirm different mode changes These functions can be switched on or off This function monitors the voltage of the input battery used to power this charger If the voltage is lower than the value set by the user the program will end to protect the input battery CHARGING LITHIUM BATTERY IN THE CHARGE MODE CHARGING OF LITHIUM BATTERY LiPo CHARGE 2 0A 11 1 V 3S INC DEC INC DEC Batt type Stop Start Enter Start Enter R 3SER S 3SER CONFIRM ENTER Li3s 1 2 A 12 59V CHG 022 43 00682 Number of cells Charging time Charging current Battery voltage Charged capacity The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set After setting the current and voltage press START ENTER key for more
12. ISCHARGE 1 0A 11 0V NiMH CYCLE DCHG gt CHG 3 Save INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC Batt type Stop Start Enter Start Enter Start Enter Voltage Data number Capacity Type of battery Set up the discharge current and final voltage Set up the charge discharge sequence and cycle number Saving the data PROGRAM SELECT LOAD DATA LOAD 01 NiMH 14 4V 3000mHh Load Loading the data Start Enter Start Enter For your convenience SKYRC QUATTRO B6AC has a data storage and load program It can store five battery data representing the respective specifications of batteries You can call back the data when charging or discharging without setting up the program again Press START ENTER key to make it blink and use INC or DEC to set up the parameter Setting of the parameter in the screen will not affect the charge and discharge process They just present the specification of the battery The example is NiMH battery pack including 12 cells the capacity is 3000m Ah Set up the charge current in the manual mode or current limit in the auto mode Press INC and DEC key simultaneously to make the current field blink to switch the charge mode This program is to load the data stored at the save data program Press START ENTER key to make the data field blink and press INC or DEC for more than 3 seconds to load the da
13. Professional Balance Charger Discharger Built In AC Power Supply U1B6M10111 Version 1 1 INSTRUCTION MANUAL SKYRC Technology Co Ltd 2011 06 C www skyrc com TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION SPECIAL FEATURES WARNING AND SAFETY NOTES PROGRAM FLOW CHART LITHIUM POLYMER BALANCE CHARGE PROGRAM INITIAL PARAMETER SETUP USERS SET UP CHARGING LITHIUM BATTERY IN THE CHARGE MODE FAST CHARGING OF LITHIUM BATTERY DISCHARGING OF LITHIUM BATTERY DISCHARGE OF NICD NIMH BATTERY CHARGING OF THE PB BATTERY STORAGE DATA PROGRAM VARIOUS INFORMATION IN THE PROGRAM WARNING AND ERROR MESSAGE SPECIFICATION RECOMMENDED ACCESSORIES CONFORMITY DECLARATION 02 04 06 10 11 12 16 17 18 18 20 21 22 23 24 25 26 INTRODUCTION INTRODUCTION Congratulations on your choice of the SKYRC QUATTRO B6AC digital intelligent charger from SKYRC Technology Co Ltd You are now the owner of a compact charger with battery management and integral balancer The unit is simple to use but the operation of a sophisticated automatic charger such as the SKYRC QUATTRO B6AC does require some knowledge on the part of the user These operating instructions are designed to ensure that you quickly become familiar with its functions It is therefore important that you read right through the Operating Instructions Warning and Safety Notes before you attempt to use your new autom
14. Supplied capacity STORAGE CONTROL OF LITHIUM BATTERY CHARGING LITHIUM BATTERY IN THE STORAGE MODE LiPo STORAGE 1 0A 11 1V 3S INC DEC INC DEC Batt type Stop Start Enter Li3s 1 0A 12 59V STO 0 22 43 00682 Number of cells Elapsed time Charge or discharge current Current voltage battery Supplied capacity The value on the left side of the second lines sets the charge current The value on the right side of the second lines sets the battery pack s voltage After setting current and voltage press STAR ENTER for more than 3 seconds to start the process This displays the number of cells you set up and the processor detects R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen If both numbers are identical you can start charging by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead This screen shows the real time status during charge process Press BATT TYPE STOP key once to stop the charge process Charging current will become lower when it progress to the end of charging A specific CV process will be reduced to end the charging process earlier In fact the charging current will goes to 1 5 when the charging process comes to 1 10 Charging capacity will be little smaller than normal charging but charging t
15. ant Before connecting a battery it is absolutely essential to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be damaged and could even burst into flames or explode To avoid short circuits between the banana plugs always connect the charge leads to the charger first and only then to the battery Reverse the sequence when disconnecting the pack INITIAL PARAMETER SETUP USERS SET UP INITIAL PARAMETER SETUP USERS SET UP USER SET PROGRAM gt LiFe V Type 3 3V LiPo LiIo LiFe CHK Time 10min INC INC DEC INC DEC By default this charger will be set to typical user settings when it is connected to DC 11 18V for the first time The screen displays the following information in sequence and the user can change the parameter on each screen If you need to alter the parameter value in the program press Start Enter key to make it blink then change the value with INC or DEC key The value will be stored by pressing Start Enter key once User setup starting screen The screen displays the nominal voltage of Lithium battery There are three kinds of Lithium battery LiFe 3 3V Lilo 3 6V or LiPo 3 7V This is very important so you have to check the battery carefully and set it up correctly If it is different from correct value the battery may be exploded during charge process SKYRC QUATTRO B6 recognize the cell count of Lithium b
16. arged capacity The value of discharge current on the left can not exceed 1C and the value on the right can not be under the voltage recommended by the manufacturer to avoid deep discharging Press START ENTER for more than 3 seconds to start discharging This shows the real time status of discharging you can press BATT TYPE STOP key to stop discharging The 4th cell was damaged The value of voltage may be zero if disconnection occurs The processor monitors voltage of each cell when the battery packs are during its storage and discharging process If voltage of any cell is abnormal SKYRC QUATTRO B6AC will show error message and terminate the program forcibly So if there is battery damage or disconnection you can see the error message and press INC to know which cell is damaged This program is for charging of NiCd NiMH batteries associated with R C models applications You can press START ENTER key to make it blink and then INC or DEC to change the parameter value Press START ENTER key to store the value The screen shows the real time status Press BATT TYPE STOP key to end the program The sound will emitted to indicates the end of program This program charge the battery using the current you set up In the auto state you should set up the upper limit of the charge current to avoid damage by excessive feeding current Some batteries of low resistance and capacity can lead to higher current in the auto charging mode But
17. atic charger for the first time We hope you have many years of pleasure and success with your new battery charger SKYRC QUATTRO B6AC is a high performance micro processor control charge discharge station with battery management suitable for use with all current battery types With integral equalizer for six cell Lithium Ion LiIon Lithium Polymer LiPo and Lithium Ferrum LiFe batteries Maximum 6A charge current can be powered by a 12 Volt car battery or from the 110V AC US Version or 220V AC via the built in switch mode power supply And the circuit features four totally independent identical power outputs which are powered 50 watts each Total powers are 200 watts As a result it can charge or discharge up to 4 x 15 cells of NiCd NiMH or 4 x 6 series of Lithium batteries simultaneously Quattro B6AC has four individual cell voltage balancer at each outputs so it does not required any balancer separately when charging Lithium Battery LiPo LiIon LiFe for voltage balancing When a Nickel battery is fully charged the unit terminates the process using the Delta Peak method Lithium and lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor Following instructions only apply to one of the four chargers as all of them operate according to same principle Please BE SURE to read these instructions and Warning and Safety Note
18. attery automatically at the beginning of charge or discharge process to avoid from erroneous setting by user But deeply discharged battery can be perceived incorrectly To prevent the error you can set the time term to verify the cell count by the processor Normally 10 minutes are enough to perceive the cell count correctly For the battery of larger capacity you may extend the time term But if you set the time term to long for the battery of smaller capacity the charge or discharge process can be finished within the time term with the erroneous cell count This may cause the fatal result If the processor recognizes the cell count incorrectly at the beginning of charge or discharge process you may extend the time Otherwise you had better use with the default value INITIAL PARAMETER SETUP USERS SET UP NIMH Sensitivity D Peak Default NICD Sensitivity D Peak Default Temp Cut off ON 80C INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC INC DEC Waste time CHG DCHG 5min Safety time ON 120min INC DEC INC DEC Safe Timer Calculation For example This shows the trigger voltage for automatic charge termination of NiMH and NiCd battery The effective value ranges from 5 to 20mV per cell If the trigger voltage is set higher there is a danger of overcharging the battery if it is set lower
19. ature Sensor Control Sockets Battery Sockets DC Input Socket Please read this entire operating manual completely and attentively before using this product as it covers a wide range of information on operating and safety Or please do use this product in company with a specialist 100 120V AC 220 240V AC US Version EU Version SPECIAL FEATURES SPECIAL FEATURES SKYRC QUATTRO B6AC allows you to plug 4 batteries into one charger simultaneously and it will intelligently and automatically charge all 4 of them at once to their maximum capacity To top of it the batteries being charged do not even need to have the same configuration You can connect different chemistry Ni MH Ni CD LiPo LiFe batteries into any of the charging ports No more staying up late for charging batteries Optimized operating software SKYRC QUATTRO B6AC features the so called AUTO function that set the feeding current during the process of charging or discharging Especially for Lithium batteries it can prevent the overcharging which may lead to an explosion due to the user s fault It can disconnect the circuit automatically and alarm once detecting any malfunction All the programs of this product were controlled through two way linkage and communication to achieve the maximum safety and minimize the trouble All the settings can be configured by users Internal independent lithium battery balancer SKYRC QUATTRO B6AC employs an individual cell vo
20. e charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged Fire or explosion can occur due to overcharging This warranty is not valid for any damage or subsequent damage arising as a result of a misuse or failure to observe the procedures outlined in this manual To avoid short circuiting between the charge lead always connect the charge cable to the charger first then connect the battery Reverse the sequence when disconnecting WARNING AND SAFETY NOTES Please bear in mind the following points before commencing charging Did you select the appropriate program suitable for the type of battery you are charging Did you set up adequate current for charging or discharging Have you checked the battery voltage Lithium battery packs can be wired in parallel and in series i e a 2 cell pack can be 3 7V in parallel or 7 4V in series Have you checked that all connections are firm and secure Make sure there are no intermittent contacts at any point in the circuit Standard Battery Parameters Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries Incorrect settings could cause the cells to fire or explode 3 7V cell Nominal Voltage Min Discharge Voltage Max Charge Voltage Storage Voltage Allowable Fast Charge 3 7V cell 4 2V cell 3 8V cell 1C
21. eries in particular should be charged strictly according to the manufacturer s instruction Close attention should be paid to the connection of Lithium batteries Do not attempt to disassemble the battery pack arbitrarily Please get highlighted that Lithium battery packs can be wired in parallel and in series In the parallel connection the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a fire or explosion Lithium batteries are recommended to charge in series WARNING AND SAFETY NOTES Discharging The main purpose of discharging is to clean the residual capacity of the battery or to reduce the battery voltage to a defined level The same attention should be paid to the discharging process as the charging process The final discharge voltage should be set up correctly to avoid deep discharging Lithium batteries cannot be discharged to lower than the minimum voltage or it will cause a rapid loss of capacity or a total failure Generally Lithium batteries don t need to be discharged Please pay attention to the minimum voltage of Lithium batteries to protect them Some rechargeable batteries have a memory effect If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their capacity next time This is a memory effect
22. ich are present at t he time of purchase During that period we will repair or replace free of service charge for products deemed defective due to those causes You will be required to produce proof of purchase invoice or receipt This warranty is not valid for any damage or subsequent damage arising as a result of misuse modification or as a result of failure to observe the procedures outlined in this manual This symbol means that you must dispose of electrical from the General household waste when it reaches the end of its useful life Take your charger to your local waste collection point or recycling centre This applies to all countries of the European Union and to other European countries with a separate waste collection system devices Electromagnetic compatibility EMC Part 6 3 Genericstandards Emission standard for residential commercial andlight industrial environments Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residential commercial and light industrial environments Electromagnetic compatibility Requirements for household appliances electric tools and Similar apparaturs Part 2 Immunity Product family standard Electromagnetic compatibility Requirements for household appliances electric tools and Similar apparaturs Part 1 Emission EN 55014 1 2006 EN55014 2 1997 A1 2001 EN61000 6 1 2007 EN61000 6 3 2007 Test Standards Title Result SKYRC QUATTRO B
23. ime will be shortened accordingly At this screen you can set up the current and voltage of the battery pack Charging and discharging will make the batteries come to the voltage level of storage state This screen shows the real time status charging Press BATT TYPE STOP key once to stop the charge process This function is for charging discharging batteries which are not used at once This program is designed for charging or discharging of batteries of specific original state They are classified by types 3 75V Lilo 3 85V LiPo and 3 3V LiFe The program will begin to discharge if the original state of the battery exceeds the voltage level of storage gt 3 seconds gt 3 seconds DISCHARGING OF LITHIUM BATTERY DISCHARGING OF LITHIUM BATTERY VOLTAGE BALANCING AND MONITORING IN THE DISCHARGE PROCESS CHARGING OF NICD NIMH BATTERY CHARGING NICD NIMH BATTERY IN THE CHARGE MODE LiPo DISCHARGE 1 0A 11 1V 3S INC INC DEC INC DEC Batt type Stop Start Enter Li3s 0 4A 12 59V DSC 022 43 00682 BATTERY VOL ERR CELL LOW VOL Number of cells Elapsed time Discharge current Battery voltage Discharged capacity The processor detects voltage of one cell is too low NIMH CHARGE Aut CUR LIMIT 5 0A INC DEC INC DEC Batt type Stop Start Enter NIMH 2 0A 7 42V CHG 022 45 00890 Battery type Elapsed time Charge current Battery voltage Ch
24. ltage balancer It isn t necessary to connect an external balancer for balance charging Balancing individual cells battery discharging During the process of discharging SKYRC QUATTRO B6AC can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal Adaptable to various type of lithium battery SKYRC QUATTRO B6AC is adaptable to various types of Lithium batteries such as Li ion LiPo and the new LiFe series of batteries SPECIAL FEATURES Fast and storage mode of lithium battery Purposes to charge Lithium battery varies fast charge reduce the duration of charging whereas store state can control the final voltage of your battery so as to store for a long time and protect useful time of the battery Maximum safety Delta peak sensitivity The automatic charge termination program based on the principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically Automatic charging current limit You can set up the upper limit of the charging current when charging your NiCd or NiMH battery it is useful for the NiMH battery of low impedance and capacity in the AUTO charging mode Capacity limit The charging capacity is always calculated as the charging current multiplied by time If the charging capacity exceeds the limit the process
25. m is only suitable for charging Pb lead acid battery with nominal voltage from 2 to 20V Pb lead acid battery is completely different from NiCd NiMH battery These batteries can only deliver current lower in comparison to their capacity The same restriction applies to the charging process Consequently the optimum charge current can only be 1 10 of the capacity Pb battery can not be used for fast charging please follow the instructions provided by the battery manufacturer Due to the chemistry characteristic of Pb battery the cut off point may be difficult to detect sometimes We recommend user to use CAPACITY CUT OFF feature to protect the battery You can press START ENTER key to make it blink and alter the value of parameters using INC or DEC key press START ENTER key to store the value Set up the charge current on the left and nominal voltage on the right Range of discharge current is 0 1 1 0A the voltage should match the battery being charged Press START ENTER key for more than 3 seconds to start charging The screen displays the real time discharging status Press START ENTER key to alter discharge current Press START ENTER key again to store the parameter value you set Press BATT TYPE STOP key to end the program gt 3 seconds gt 3 seconds STORAGE DATA PROGRAM STORAGE DATA PROGRAM LOAD DATA PROGRAM PROGRAM SELECT SAVE DATA SAVE 01 NiMH 14 4V 3000mHh NiMH CHARGE At CUR LIMIT 5 0A NiMH D
26. or just slightly discharged Non rechargeable batteries pose an explosion hazard Batteries that require a different charge technique from NiCd NiMh LiPo or gel cell Pb lead acid battery A faulty or damaged battery A battery fitted with an integral charge circuit or a protection circuit Batteries installed in a device or which are electrically linked to other components Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger delivers during the charge process WARNING AND SAFETY NOTES WARNING AND SAFETY NOTES The allowable DC input voltage is 11 18V DC The allowable AC input voltage is 100 120V AC US Version or 220 240V AC EU Version These warnings and safety notes are particularly important Please follow the instructions for maximum safety otherwise the charger and the battery can be damaged or at worst it can cause a fire Never leave the charger unattended when it is connected to its power supply If any malfunction is found TERMINATE THE PROCESS AT ONCE and refer to the operation manual Keep the charger well away from dust damp rain heat direct sunshine and vibration Never drop it This charger and the battery should be put on a heat resistant non flammable and non conductive surface Never place them on a car seat carpet or similar surface Keep all flammable volatile materials away from the operating area Make sure you know the specifications of the battery to b
27. r of cycles on the right The range of the cycle number is 1 5 Press BATT TYPE STOP key to stop program you can press START ENTER key to alter charge current The sound indicates the end of program When it approaches to the end you can see the capacity of the battery being charged or discharged You can press INC or DEC key to display result of each cycle gt 3 seconds gt 3 seconds CHARGING OF THE PB BATTERY CHARGING OF THE PB BATTERY DISCHARGING OF THE PB BATTERY CHARGING PB LEAD ACID BATTERY IN THE CHARGE MODE Pb CHARGE 4 0A 12 0V 6P INC DEC INC DEC Batt type Stop Start Enter Pb 6 4 0A 12 59V CHG 022 43 00682 Battery type Elapsed time Charge current Battery voltage Charged capacity Pb DISCHARGE 1 0A 12 0V 6P INC DEC INC DEC Batt type Stop Start Enter Pb 6 4 0A 12 59V DCS 022 43 00682 Battery type Elapsed time Discharge current Battery voltage Discharged capacity Set up the charge current on the left and nominal voltage on the right Range of current is 0 1 6 0A the voltage should match the battery being charged Press START ENTER key for more than 3 seconds to start charging The screen displays the real time discharging status Press START ENTER key to alter discharge current Press START ENTER key again to store the parameter value you set Press BATT TYPE STOP key to end the program This progra
28. s before you use the charger for the first time It can be dangerous to mis handle batteries and battery chargers as there is always a risk of batteries catching fire and exploding This charger is designed and approved exclusively for use with the types of battery stated in these Instruction Manual SKYRC accepts no liablility of any kind if the charger is used for any purpose other than that stated We are unable to ensure that you follow the instructions supplied with the charger and we have no control over the methods you employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and operation of our products or which are connected with such operation in any way Unless otherwise prescribed by law our obligation to pay compensation regardless of the legal argument employed is limited to the invoice value of those SKYRC products which were immediately and directly involved in the event in which the damage occurred EU Version Liability Exclusion INTRODUCTION Menu Control Buttons Menu Control Buttons LCD Screen Battery Battery Sockets Universal Balancing Port Pitch 2 54mm Universal Balancing Port Pitch 2 54mm AC Input Power Port Temp Sensor PC Link Available for 1 amp 3 only output Temp Sensor PC Link Available for 2 amp 4 only output Ventilation Fan with Temper
29. ta Choose the data number you want to call back The data you want to call back will be displayed gt 3 seconds gt 3 seconds gt 3 seconds VARIOUS INFORMATION IN THE PROGRAM VARIOUS INFORMATION IN THE PROGRAM It comes to the final voltage when the program ended End Voltage 12 6V 3S Capacity Cut Off ON 5000 mAh Safety Timer ON 200 min Temp Cut Off ON 80C 176F Ext Temp 26C IN Power Voltage 12 56V DEC DEC DEC DEC DEC DEC Displayed temperature cut off function is turn on Present input voltage You can inquire various information on the LCD screen during the charging and discharging process Press DEC key the charger will display users setting You can press INC key to monitor voltage of each cell while the battery is connected With each port of the charger Displayed capacity cut off function is turn on and the setting value of capacity Displayed safety timer is turn on and duration of time in minutes The external temperature is displayed when the temperature probe is used The battery is connected with each port through cable You can check voltage of each cell in the battery pack When the cable is connected with the ports on the charger the program will display voltage of up to 6 batteries 4 14 4 16 4 09 0 00 0 00 0 00 WARNING AND ERROR MESSAGE WARNING AND ERROR MESSAGE Incorrect polarity connected REVERSE POLARITY BATTERY CHECK LOW VOLTAG
30. there is a possibility of premature termination Please refer the technical specification of the battery NiCd default 12mV NiMH default 7mV An optional feature using temperature probe contacting the surface of battery the temperature cut off can be on or off If it is on set the maximum temperature at which the charger should allow battery to reach during charge Once a battery reaches this temperature during charge the process will be terminated to protect the battery The battery becomes warm after cycles of charge discharge process The program will insert a time delay after each charge discharge process to allow the battery enough time to cool down before beginning next cycle of charge discharge process The valid value ranges from 0 to 60 minutes When the charge process starts the integrated safety timer starts to run simultaneously If an error is detected or the termination circuit cannot detect whether the battery is fully charged or not the unit is programmed to prevent overcharging Please refer to the below statement to calculate the safe timer to be set When charging NiCd or NiMH batteries divide the capacity by current then divide the result by 11 9 set this number of minutes as the value for safety timer setting If the charger stopped at this time threshold about 140 of the capacity will have been fed into the battery Capacity Current Safety Time 2000mAh 2 0A 2000 2 0 1000 11 9 84 minutes 3300mAh 3 0A 330