1. Upper hinge Disengage the door from the support upper hinge Plastic hinge Reverse this procedure to refit Avoid releasing the door closure spring by leaving it attached to the bottom of the door If changing the spring cartridge pretension the spring by using the Hinge spring hinge as if it were a spanner cartridge rotate it 120 in the direction the door opens Pack piale M6 bolts Lower hinge H support Ss Notice Installation n 648282 Page 12 5 WIRING DIAGRAMS 5 1 BR 3 MECHANICAL REGULATION SCHEMATIC DIAGRAM n SE287 i On Off button Th Thermostat Tr Transformer 12V Sp Core probe Sa Ambient probe IPF Fragile products switch Vc Condenser fan Cp Compressor Minuterie 2 hour timer Cycle Cycle switch Kmc Control contactor Ve Evaporator fan Cd Condenser Cycle light Rev Evaporation element Notice Installation n 648282 Page 13 5 2 BR 6 MECHANICAL REGULATION SCHEMATIC DIAGRAM d m D n SE289 Kmg Compressor contactor Vc Condenser fan Cp Compressor On Off switch Th Thermostat Tr Transformer 12V Sp Core probe Sa Ambient probe IPF Fragile products switch Ev Solenoid Minuterie 2 hour timer Cycle Cycle switch Kmc Control contactor Ve Evaporator fan Cd Condenser VC Cycle light Rev Evaporation element
2. Galvanized chassis compressor assembly S015PR67 Stainless chassis compressor assembly e S015PG Stainless Galvanized chassis compressor assembly e S015PS Stainless Galvanized chassis compressor assembly e 5185 40 12 TB compressor e S177P40 MP 14 TB compressor e 5057 30 104270 condenser e S049P30 5 273 condenser with fan dia S072P40 EVR10A 254 condenser fan e S239P46 EVR10A 254 fan venturi e S021P20 Dryer 15 grs XH9 e S022P20 Dryer 30 grs XH9 e S118P40 Storage bottle 0 7 litres 5074 20 solenoid e S165P19 Liquid sight glass MIA 014 S014PG67 Capillary evaporator housing e S014PH67 T E V evaporator housing SG e 014 67 evaporator housing e x2 S040P30 Evaporator battery 5N4T 350 LT e e S155P15 fan 2VGV 25 250A 981P70 15 10 2 5m long e e S141P20 52 T E V e e S137P20 T E V nozzle n 02 e e S161P20 T E V 4 adapter e e S109P11 Rigid PVC drain elbow S330P11 Plastic re evaporation container 142P15 PTC heated cartridge S067PJ67 Control pane assembly e e S068PJ67 Control panel assembly SG e e S723P48 Control panel e e S725P48 Control panel SG e e S664P48 Facia grill GI S666P48 Facia grill SG e e S409P 11 Label for facia grill and control panel S411P11 Control label for control panel Notice Installation n 648282 Page 16 ELECTRO REFRIGERA
3. Notice Installation n 648282 Page 14 6 SPARE PARTS 6 1 BODYWORK BR 3 BR 6 Code Description e S008PA57 Right hand door without lock with hinges and handle o 008 57 hand door without lock with hinges and handle e S009PA57 Right hand door with lock hinges and handle e 5009 57 Left hand door with lock hinges and handle e e 5085 01 Delrin door hinge e e S083P01 Spring door hinge e e 5672 48 Delrin top hinge support for left hand door e e 5672 48 Delrin top hinge support for right hand door e e 5051 01 hinge support for left hand door e e 5051 001 Bottom hinge support for right hand door e e S409P 11 Door and drawer label S396P 11 Magnetic door seal 420 x 585 S053P01 Lock S064P01 Latch pin S674P48 Catch S011P02 Rear lock hole cover S064P02 Stainless legs M12 63 150 200 high e e 129 02 100mm braked caster 130PA02 100mm plain caster S698P48 Side runner supports e S779P48 Side runner supports e S780P48 Rear runner hooks e S651P48 Technical housing side Notice Installation n 648282 Page 15 6 2 ELECTRO REFRIGERATION EQUIPMENT BR 3 BR 6 Code Description e 015 67
4. BLAST CHILLER BIOTOP Mechanical Regulation BR 3 BR 6 CONTENTS Important recommendations 2 1 Technical data 3 2 Installation 5 3 Commissioning 7 4 Breakdowns and trouble shooting 10 5 Wiring diagrams 13 6 Spare parts 15 BONNET GRANDE CUISINE Rue des Fr res Lumi re 2 1 Mitry Compans 77292 MITRY MORY cedex T l 01 60 93 70 00 Fax 01 60 93 70 43 IMPORTANT RECOMMENDATIONS When installing ensure that the air circulation and volume are adequate for the normal cooling of the condenser and compressor Avoid locating the unit adjacent to a significant heat source or in direct sunlight Note that abnormally high ambient temperature will reduce the performance of the unit This unit must be earthed check the earth continuity wiring The supply cable which is delivered with the appliance is a specific part which should only be replaced by an original part This appliance should be protected by a suitably rated fuse or circuit breaker on the supply see rating plate Before any work is undertaken on the electrical circuits the refrigeration or before cleaning the unit must be switched off or unplugged The compressor condenser should be cleaned regularly every 3 to 6 months Water splattering can cause damage Do not clean with a water jet in order to avoid splattering the appliance Do not install the appliance in the open air or in the rain Always ensure that t
5. VENTILATION In order to guarantee refrigeration performance check that none of the air inlets outlets or ducts are blocked in any way Notice Utilisation n 648282 Page 6 2 4 DEFROST Before each cycle check the quantity of frost on the evaporator If this is significant enough to risk blocking the evaporator a defrost is required See paragraph 1 9 for how to do this 2 5 CONDENSATE WATER COLLECTION A container within the technical compartment collects defrost water which is re evaporated automatically by a self regulating heating element 3 SERVICE IMPORTANT Before any cleaning operation ensure the appliance is switched OFF Do not clean the appliance with a water jet in order to avoid water splattering 3 1 INTERIOR LINING Any dirt and stains should be eliminated once per day To facilitate the complete cleaning of the interior the internal fitting can be removed easily shelves slides and slide supports 3 2 STAINLESS STEEL SURFACE Using warm water and soap or a non corrosive neutral detergent such as teepol or an equivalent product Carefully rinse and dry the appliance Never use Javell water even when highly diluted Never rub stainless steel with metal wool if necessary use only scotch brite or an equivalent product Fingerprints in particular can be easily removed by rubbing with a cloth soaked in alcohol 3 3 PERIODICAL CLEANING Magnetic door seal can be removed to ease cleaning In o
6. of the set point 55 99 C 2 15 COMPRESSOR PROTECTION CO Delay at power up 0 15 min 0 C1 Delay after start 0 15 min 0 C2 Delay after stop 0 15 min 0 C4 Delay ON OFF 0 0 1 3sec 0 1 0 C5 Compressor cycle duration if probe faulty 0 240 min 1 C6 Percentage of C5 if probe faulty 0 100 95 100 DEFROST DA Reading the ambient probe ALARMS specific to SR2 and SM2 models 3 AO Alarm differential 1 15 C 2 1 A1 Low alarm relative to the set point 0 55 0 2 0 A2 High alarm relative to the set point O none 0 99 2 0 A3 Alarm exclusion at power up 0 15 H 0 A6 Exclusion time if A1 and or A240 0 99 min 0 ALARMS all models except SR2 and SM2 4 0 Alarm differential 1 15 C 2 1 1 A1 Low alarm relative to the set point O none 55 99 C 2 7 A2 High alarm relative to the set point O none 0 120 2 0 A3 Alarm exclusion at power up 240 min 0 A6 Exclusion time if A1 and or A220 0 240 min 0 FRAGILE PRODUCTS all models except SR2 and SM2 4 F1 Set point F2 Differential SERIAL PORT FOR DATA EXCHANGE 0 1200 1 2400 Parameters accessible on level 1 Units depend of the setting of parameter 8 2 4800 3 9600 Notice Installation n 648282 Page 9 4 BREAKDOWNS AND TROUBLE SHOOTING IMPORTANT Before any operation ensure the unit is SWITCHED OFF 4 1 ACCESS TO COMPRESSO
7. und den Bestimmungen der elektromagnetischen bereinstimmung richtlinie EWG 89 336 Il est galement conforme aux dispositions de normes europ ennes harmonis es suivantes It is in compliance with the following harmonized standards Und entspricht ebenfalls der folgenden Europaischen Norme EN 60335 1 S curit des appareils lectrodomestiques et analogues Safety of household and similar electrical appliances Elektrische Ger te f r den Hausfebrauch und hnliche Zwecke DIRECTION GENERALE General Manager Betriebsleiter FORMO55A1 1 Si ge Social BONNET GRANDE CUISINE Rue de Fr res Lumi re 7 1 de COMPANS 77292 MITRY MORY CEDEX T l 0160937000 Fax 0160937043 S A S au capital de 1 600 000 Euros RCS MEAUX B 319 053 005
8. ENTATION OF THE CONTROL PANEL See USER MANUAL 3 3 ELECTRONIC THERMOSTAT 4 5 D Set button 5 Fragile product function LED Decrease button End of cycle alarm function button Increase button End of cycle alarm function LED Compressor running LED 3 39 1 THERMOSTAT CONFIGURATION To alter the set points see paragraph 1 3 of the operating manual There are 2 levels of configuration Level 1 For the password to level 2 code PA To change the differential code ro calibrate the probes codes 1 and 6 To read the ambient temperature probe code dA To adjust the end of cycle alarm code A1 Level2 Starting from level 1 all the parameters can be modified password protected see table of parameters Notice Installation n 648282 Page 7 ACCESS TO LEVEL 1 Press both arrows buttons 2 and 3 for 4 sec PA appears in the display Press the arrows buttons 2 or 3 To select the parameter to change Then press SET button 1 and adjust with the arrows buttons 2 or 3 ACCESS TO LEVEL 2 To see and then modify the value of the selected parameter starting from level 1 having selected parameter PA Press and hold SET button 1 and adjust with the arrows buttons 2 or 3 To adjust the value 19 Press both arrows buttons 2 and 3 for 4 sec The first parameter of level 2 is displayed 0 Press the arrows buttons 2 or 3 Th
9. R In order to clean the condenser access requires the removal of the facia grill Facia grill 2 X CL M6 screws Control panel 2 X CL M6 screws Remove the facia grill by undoing the 2 screws from the lower edge then disengage the pins that locate in the bottom of the control panel The option compressor on pull out runners helps with this operation as it gives full access to the compressor ensure that the hoses are not constrained in anyway during this operation 4 2 ACCESS TO THE ELECTRIC CARD The electric control card is behind the control panel Having removed the grill undo the 2 screws from the lower edge of the control panel and draw it out so as to disengage it from the top frame Notice Installation n 648282 Page 10 4 3 ACCESS TO THE EVAPORATOR HOUSING 4 3 1 BR CABINET Access to the evaporator is gained by removing the fan chicane N Fan chicane 4 x CL M5 screws 4 3 2 BR 6 CABINET Access to the evaporator is gained by opening the fan chicane re e SCH N Fan chicane 2 x CL M5 screws Notice Installation n 648282 Page 11 4 4 REMOVING AND REPLACING DOORS Open the door and completely remove the lower hinge support with a 10mm pipe spanner
10. TECHNIQUE UNDERCOUNTER UNIT GN1 1 BLAST CHILLER BIOTOP Mechanical Regulation BR 3 BR6 TECHNICAL MANUAL USER MANUAL INSTRUCTIONS DOCUMENTATION EI FORMO5081 1 n 648282 05 06 USER MANUAL UNDERCOUNTER UNIT GN1 1 BLAST CHILLER BIOTOP Mechanical Regulation BR 3 BR 6 CONTENTS Important recommendations 1 Presentation of the control panel 2 Operating 3 Maintenance N O C nm 4 Trouble shooting BONNET GRANDE CUISINE Rue des Fr res Lumi re 7 1 Mitry Compans 77292 MITRY MORY cedex T l 01 60 93 70 00 Fax 01 60 93 70 43 Notice Utilisation n 648282 Page 1 IMPORTANT RECOMMENDATIONS Designed for use in Restaurants and Catering establishments this piece of equipment is not intended for industrial operations Installation should be undertaken by a specialist engineer Avoid locating the unit adjacent to a significant heat source or in direct sunlight Note that abnormally high ambient temperature will reduce the performance of the unit The compressor condenser must be cleaned regularly every 3 to 6 months by a qualified technician Do not modify the wiring to the unit in particular the earth continuity wiring The supply cable which is delivered with the appliance is a specific part which should only be replaced by an original part n the event of a problem with the electrical circuit only a qualified technician or the manufact
11. TION EQUIPMENT cont BR 3 BR 6 Code Description S095P20 Electronic thermostat FK901A e 210P15 button S211P15 switch 212P15 Fragile products switch S112P15 Transformer 12V e e S194P20 Ambient probe S096P20 Single point core probe S012PR67 Electrical box assembly 5012 567 Electrical box assembly S013PR67 Electrical box assembly SG e S013PS67 Electrical box assembly SG e S103P15 Control contactor CA2 KN22 M7 e e S104P15 Compressor contactor LC1 0910 M7 e e S845P51 Supply cable S058P15 Supply cable termination GI With compressor SG Without compressor Notice Installation n 648282 Page 17 BONNET DECLARATION DE CONFORMITE CONFORMITY DECLARATION HERSTELLERKONFORMITATSERKLARUNG TYPE TYP N DE SERIE SERIAL N FAB Nr Sn ae en coe Nahe co ee ah el Cet appareil est conforme aux dispositions de la directive Basse tension 73 23 CEE et de la directive Compatibilit lectromagn tique 89 336 CEE This appliance complies with the provisions of the low voltage directive EEC 73 23 and with the provisions of the electromagnetic compatibility directive EEC 89 336 Dieses Ger t entspricht nach den Bestimungen der niederspannung richtlinie EWG 73 23
12. button End of cycle alarm function LED The digital electronic thermostat indicates the temperature detected by the ambient probe To display the set temperature press Set button 1 Change this setting by continuing to press the Set button and pressing the arrows 2 or 3 to decrease or increase the temperature setting To silence an audible alarm press button 2 to stop the buzzer A manual defrost can be started by pressing button 3 Notice Utilisation n 648282 Page 1 4 FRAGILE PRODUCTS In probe mode this function allows the processing of fragile items with a low density where the chiller has to operate with a small load without surface freezing frost crusting This function is actuated or deactivated using switch 6 on the control panel and is indicated by the 5 LED on the regulator The air temperature is limited to 15 C depending on the parameter settings see the table of parameters in the installation instructions 1 5 END OF CYCLE ALARM This function allows for an alarm to sound at the end of the cycle depending on the set point and in relation to the setting of A1 on the regulator see table of parameters in the installation instructions This function is actuated or deactivated by holding button 6 on the regulator for more than 4 secs and is indicated by the 7 LED on the regulator With the audible alarm the end of cycle is still indicated by the flashing of the digi
13. en press SET button 1 and adjust with the arrows buttons 2 or 3 To select the parameter to change To see and then modify the value of the selected parameter To exit press both arrows at the same time buttons 2 and 3 for 4 seconds or wait at least 50 seconds without touching anything 3 3 2 SIGNALS AND ALARMS EO Flashes on the display and the buzzer sounds intermittently when the probe is faulty or the temperature is outside the limits of the thermostat E1 Flashes on the display and the buzzer sounds intermittently when the ambient probe is defective E2 Flashes on the display and the buzzer sounds intermittently for a configuration memorization fault switch off and on again A1 Flashes on the display and the buzzer sounds intermittently if the temperature is outside the alarm parameters parameter A1 or A2 It should be noted that flashing LED indicate a delayed start for the corresponding function Notice Installation n 648282 Page 8 3 39 8 TABLE OF PARAMETERS Code Parameters Min Max Unit Factory Password Tobesetto 19 99 99 PROBE D Type of probe 1 PTC 3 NTC Probe calibration 8 points to correct 1 1 6 Evap probe calibration 8 points to correct 1 18 Unit of temperature TEMPERATURE REGULATOR 0 F 1 1 10 Differential 1 15 C 2 2 ri Minimum value of the set point 55 99 2 0 r2 Maximum value
14. for a chill cycle OFF for a freeze cycle 4 Check that the probe is correctly located in its holder 5 Switch the end of cycle alarm off 6 Start the cycle with the cycle selector switch position II The thermostat instantly displays the air temperature Whilst the unit is working on timer the fragile product function is not operational With the end on cycle alarm actuated it will sound before the cycle ends as the air temperature reaches the thermometer set point At the end of the cycle indicated by the orange light the system automatically switches to cyclical operation controlled by the thermostat Press the cycle switch position O to stop the unit and allow product to be loaded 8 PROBE CYCLE Loading done and the power on On Off button 1 Locate the probe in the product to be chilled 2 Check and if necessary adjust the set point 3 for blast chilling 20 C for blast freezing only combined models 3 Switch the fragile product function ON for a chill cycle OFF for a freeze cycle 4 Switch the end of cycle alarm on 5 Start the cycle with the cycle selector switch position II The thermostat instantly displays the air temperature At the end of the cycle signalled by the alarm the system automatically switches to cyclical operation to hold temperature until it is unloaded In probe cycle mode without timer the orange cycle light indicates that the compressor is running it is therefore the
15. he unit is maintained as it was when it left the factory or there is a risk that safety will be compromised WE RESERVE THE RIGHT TO AMEND SPECIFICATIONS AND CHARACTERISTICS WITHOUT NOTICE Notice Installation n 648282 Page 2 1 TECHNICAL CHARACTERISTICS 1 1 BR 3 CONSTRUCTION 1000 56 90 The exterior casing sides top facia doors amp the interior are austenitic stainless steel The rear panel the underside of the base and the compressor housing chassis are in galvanised anticorrosion sheet steel Technical compartment is on the right of the unit Insulated body APIS Monocoque type Radiused interior Polyurethane foam insulation 60mm thick 100 Legs comprising 4 adjustable feet for levelling or optional castors Doors Fitted with push fit magnetic seals Self closing doors with a stay open position GENERAL CHARACTERISTICS Blast chilling from 63 C to 10 in less than 2 hours Capacity 12 kg chilling Ambient operating temperature 43 ELECTRICAL CHARACTERISTICS 1107 500 56 250 700 Rating 1 230V 50Hz E Max power 850 watts 2 Protection aM 4 4 Theunitis supplied with cable and a plug The supply to the unit should be protected by using a suitable c
16. ircuit breaker or fuse in conjunction with a residual current devise REFRIGERATION CHARACTERISTICS Refrigeration 733 watts at 15 55 C Refrigerant R404A 665 840 900 175 Load See appliance instruction plate Compressor Hermetic Condenser Forced air Top with upstand Top without upstand Evaporator Ventilated corrosion proof Defrost Forced air Defrost water Automatic re evaporation of defrost water by self regulated heater Conforms to norms and directives Electrical safety EN 60 335 1 Food hygiene XP U 60 010 Complies with European directives concerning CE Notice Installation n 648282 Page 3 1000 1 2 BR 6 61 1500 56 1250 00 1300 100 700 D LL OR 840 900 8 5 372 81 103 103 Top with upstand Top without upstand CONSTRUCTION The exterior casing sides top facia doors amp the interior are austenitic stainless steel The rear panel the underside of the base and the compressor housing chassis are in galvanised anticorrosion sheet steel Technical compartment is on the right of the unit Insulated body Monocoque type Radiused interior Polyurethane foam insulation 60mm thic
17. k Legs comprising 4 adjustable feet for levelling or optional castors Doors Fitted with push fit magnetic seals Self closing doors with a stay open position GENERAL CHARACTERISTICS Blast chilling from 63 C to 10 C in less than 2 hours Capacity 25 kg chilling Ambient operating temperature 43 C ELECTRICAL CHARACTERISTICS Rating 1 280V 50Hz E Max power 1300 watts Protection aM 8 The unit is supplied with cable and a plug The supply to the unit should be protected by using a suitable circuit breaker or fuse in conjunction with a residual current devise REFRIGERATION CHARACTERISTICS Refrigeration 884 watts at 15 55 C Refrigerant R404A Load See appliance instruction plate Compressor Hermetic Condenser Forced air Evaporator Ventilated corrosion proof Defrost Forced air Defrost water Automatic re evaporation of defrost water by self regulated heater Conforms to norms and directives Electrical safety EN 60 335 1 Food hygiene XP U 60 010 Complies with European directives concerning CE Notice Installation n 648282 Page 4 2 INSTALLATION 2 1 GENERAL REQUIREMENTS The installation modification or repairs to this equipment should only be undertaken by a qualified technician 2 2 HANDLING The unit should be handled with suitable lifting equipment If the unit is to be transported this should be done whilst it is still in its original packing i
18. rder to maintain the refrigerating capacity and to ensure the longevity of the compressor the condenser must be cleaned regularly every 3 or 6 months This operation must be carried out by a qualified technician Notice Utilisation n 648282 Page 7 4 TROUBLE SHOOTING In the event of abnormal operation and before requesting an after sales call Causes Checks and Remedies Unit does not come on using the On Off No power to the unit button Check that the unit is plugged in Check the fuses and or M C B protecting the socket Unit stops in mid cycle Power cut Check the fuses and or M C B protecting the socket The compressor works intermittently Compressor safety thermostat Check that the condenser fan is working Check that the condenser is not choked up Check the ambient temperature Increase air flow if necessar The refrigeration unit compressor and Safety pressostat tripped condenser fan works intermittently Check that the condenser fan is working Check that the condenser is not choked up Check the ambient temperature Increase air flow if necessar The cycle exceeds the statutory time limit Too much product loaded Reduce the load Ambient temperature too high Increase ventilation Evaporator iced up Run a defrost Evaporator fans blocked Clean them Condenser choked up Clean it out Notice Utilisation n 648282 Page 8 INSTRUCTIONS UNDERCOUNTER UNITS GN1 1
19. t should not be stacked If itis subsequently moved it should be lifted and not dragged 2 3 UNPACKING amp INSTALLATION 2 3 1 LOCATION When selecting a location ensure there is adequate air circulation to provide adequate cooling for the compressor Avoid locations adjacent to a heat source 2 3 2 UNPACKING After removing the packing lift the unit off its wooden pallet Set the worktop height between 875 and 925mm Level the unit using the adjustable feet EE a a 7 4444 4 4 a A 4 a Wooden pallet Notice Installation n 648282 Page 5 2 3 3 CONNECTIONS See paragraph 1 Technical characteristics ELECTRIC The unit is fitted with a plug which should not be removed This appliance must be EARTHED see important recommendations The supply should incorporate a suitable fuse or circuit breaker DEFROST WATER A container within the technical compartment collects defrost water which is re evaporated automatically by a self regulating heating element Notice Installation n 648282 Page 6 3 COMMISSIONING 3 1 GENERAL REQUIREMENTS Check that nothing is obstructing the evaporator or condenser fans If during transport or installation the appliance has been laid on its side allow it to stand for 24 hours to ensure that the oil has drained back to the compressor sump For units with grills fit the runners onto the uprights 3 2 PRES
20. tal display To stop the buzzer press button 6 on the regulator 1 6 PRE CHILL CYCLE Before introducing foodstuffs to be chilled or frozen it is advisable to run a pre chill cycle to chill everything down so that the best refrigeration performance is obtained when loaded with product 1 Switch the chiller on using the On Off button 2 Set the timer to 15 mins 3 If necessary check the set point on the thermostat 3 for blast chilling 20 C for blast freezing only combined models 4 Switch the fragile products button to OFF 5 Check that the probe is correctly located in its holder 6 Switch the end of cycle alarm off 7 Start the cycle with the cycle selector switch position II The thermostat instantly displays the air temperature If the end on cycle alarm is on it will sound before the cycle ends as the air temperature reaches the thermometer set point At the end of the cycle indicated by the orange light the system automatically switches to cyclical operation controlled by the thermostat Press the cycle switch position O to stop the unit and allow product to be loaded Notice Utilisation n 648282 Page 4 1 7 TIMER CYCLE Loading done and the power on On Off button 1 Adjust the timer to suit the amount and type of products 2 Check and if necessary adjust the set point 3 for blast chilling 20 C for blast freezing only combined models 3 Switch the fragile product function ON
21. temperature reading displayed by the thermostat and the alarm that indicates the end of cycle Switch the cycle button to O to stop the unit for unloading To switch off completely use the On Off button Notice Utilisation n 648282 Page 5 1 9 DEFROST CYCLE Before each cycle check the quantity of frost on the evaporator If this is significant enough to risk blocking the evaporator a defrost is required 1 8 1 NATURAL DEFROST With the unit switched off leave the door ajar 1 8 2 FORCED DEFROST With the unit switched on On Off button 1 Set the timer from 15 to 30 mins 2 Start a defrost with the cycle selector switch in position I Only the evaporator fans will function The cycle ends automatically indicated by the orange light Switch the cycle selector to O to stop the unit and prepare for a chilling cycle 2 USE 2 1 GENERAL REQUIREMENTS Always locate the products to be chilled in such a way that there is no obstruction to the circulation of air around the interior When it is not in use timer cycle always ensure that the probe is correctly located in its holder so that the internal air temperature is measured correctly 2 2 LOADING Product should be loaded with a space of at least 15mm between items so that cold air can circulate between them The time required for chilling or freezing is a function of the load its nature thickness and density so chilling capacities are only indicative 2 3
22. urer should intervene To ensure good standards of hygiene regularly clean Interior fittings Door seals Inside the compartment Do not use corrosive products or acids Water splattering can cause damage Do not clean with a water jet to avoid the risk of splattering the appliance Do not install the appliance in the open air or in the rain WE RESERVE THE RIGHT TO AMEND SPECIFICATIONS AND CHARACTERISTICS WITHOUT NOTICE Notice Utilisation n 648282 Page 2 1 PRESENTATION OF THE CONTROL PANEL 1 1 IMPORTANT The thermostat does not cut the supply to the unit In the event that the unit is not in use for some time switch off or unplug completely to avoid the risk of damage to the refrigeration equipment 1 2 CONTROL PANEL DESCRIPTION Timer to control the cycle duration ds running vien edly cycle 120mins for chilling 19 selector switc 120 t 190 20 sol m mMm mlo GID Leet Got He j 4 amp eo ZT On Off Fragile product Control Button switch thermostat 1 3 USING THE ELECTRONIC CONTROL THERMOSTAT D Set button Decrease button Q Increase button Compressor running LED 6 Fragile product LED End of cycle alarm function