Home
WT-1010
Contents
1. WT 1010 GSM For Alarm System User Manual Fixed Wireless Terminal INHEP DIGITAL SECURI The WT 1010 GSM Terminal is a wireless communicator for alarm and fire panels that uses the cell phone network GSM to transmit alarms and other panel event The module checks the status of the PSTN line and in case the PSTN line becomes unavailable the WT 1010 GSM emulate the line signal to the panel At this time the panel will dial out using the GSM cell phone network to communicate with the receiver at the monitoring station and transmit the alarms GENERAL OVERVIEW Mobile Alarm sent Specific Data SMS Mobile Alarm sent Specific Data SMS Receiver Transmission via PSTN Line Alarm Reception on Processing by Standard Receiver operator WT 1010 User Manual Rev 2 6 IDS 2 FEATURES La Reception on Mobile Mobile Reception on Specific DATA Processing by Receiver operator rr rr rr rte rere eee Specific Data SMS Panel HE VOICE Dialer oS Alarme Va seweoesecesveoeuseces ees AA ALLE Peewee eee wwe eee eee wee ee eee eee eee eS Reception on Standard Receiver Panel compatibility Allows any contact ID alarm panel to transmit alarms over GSM using the GSM voice channel Works over the GSM cell phone networks Units can be used wherever there is cell phone coverage Telephone line backup WT 1010 give priority to the lowest c
2. al for controlling outputs and inputs TEL PORT 1 ALARM INPUT Connect to Alarm Panel also function as Phone Input TEL PORT 2 Connect to PSTN Line ANTENNA PORT ON OFF SWITCH POWER PORT Connect the provided Turn On or Off the Connect a 12V Power antenna to the Terminal Supply to the Terminal Terminal Rear view WT 1010 User Manual Rev 2 6 IDS 4 Panel Power pa Supply WT 1010 RS232 WIRING DIAGRAM On WT 1010 z H l di m ji l LI bo 8 8 8 8 Bu WT 1010 User Manual Rev 2 6 IDS WT 1010 WIRING per 1 Antenna connect the antenna to the GSM module place the antenna as far as possible from the WT 1010 and do not leave any coiling of the antenna cable to avoid radiant interference 2 SIM Card disable the PIN code and set it to 1234 default For Transmitter Mode Data or SMS as with any transmitter it reguires an identifier receiver telephone numbers etc refer to the complete information on Programming page 3 Line Input connect the line input to the PSTN or ISDN network 4 Outputs Back Up Mode connect the RS232 to additional remote controlling outputs 5 Alarm Input connect the input to output of the Alarm Panel Control Pane
3. door is opened illegally WT 1010 will receive short circuit impulse on ZONE4 and will automatically send a signal to the monitoring station and also send a SMS to notify the owner PROGRAMMABLE ALARM SMS User is able to change the content of alarm SMS for ZONE4 ZONES and ZONEG For Example ZONE4 is connected to garage door and programmed as Garage Opened when ZONE4 is triggered owner will receive a SMS Garage Opened Note When sending normal SMS with command below to the WT 1010 it will reply a message to a programmable phone number indicate that the setting has changed successfully Description Reply from WT 1010 IN1 Text Messages Allow user to change the content of Changed Done IN2 Text Messages alarm message for inputs up to 19 Changed Done IN3 Text Messages Characters Changed Done Erase all programmed text messages WT 1010 User Manual Rev 2 6 IDS 7 12VDC 12VDC BUZZER VCC VCC input 1 2 3 output 4 5 6 RELAY 12V is Raad ZONE INPUT OUTPUT Inputs And Outputs Wiring Diagram INSTALLING THE SIM CARD Proceed as follows 1 Slide back the SIM door and lift it up 2 Slide the SIM card into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3 Close the SIM door 4 Slide the SIM door to lock the SIM card in place POWER UP THE WT 1010 g When power up the WT 1010 it will disp
4. e WT 1010 available it will receive the message and will automatically reply the user I f the WT 1010 GSM Service is If the GSM Service failed it will not reply the user To check network status send AT010 normal SMS to the WT 1010 If the GSM Service is available it will reply GSM OK WT 1010 User Manual Rev 2 6 IDS VERIFICATIONS AND TESTS Line Detect Simulate a line failure disconnect the PSTN line from line port of WT 1010 and the transmission of the PSTN fail alarm by WT 1010 will be sent Check that the SMS has been sent to the mobile recipient if SMS transmission is programmed Reconnect the line Check the transmission of PSTN line restore by the WT 1010 to the GSM Data receiver of the Monitoring Station Simulate both GSM and PSTN failure take out the SIM card from the WT 1010 and disconnect the PSTN line check that the voltage on GSM amp PSTN failed Output that will trigger the Alarm Siren TECHNICAL SPECIFICATIONS General SIM300 GSM GPRS Module with OdB antenna 2 5m Optional accessory remote antenna 10m cable 2dB gain Marine Type with FME MMCX connector CE Intrusion Product Compatibility Compatible in GSM Voice communications with any DTMF Control Panel including speech synthesis Panels and any landline alarm receiver Compatible in SMS transmission to any mobile phone text formatted SMS and to any SMS receiver RD id Type Contact ID formatted SMS Compatib
5. l 6 Power Supply connect to a 12V power supply 7 Operating State Approximately 20s after power up check the operating state indicated by the Power LED the LED is steady during power up phase then blinks when the connection to the GSM network is established The Signal indicator LED will stay lit whenever there is signal WT 1010 RS232 WIRING ZONE1 Red ZONE2 Blue ZONE3 Yellow Remote Controlling Outputs Connect ZONE1 ZONE2 and ZONE3 to additional outputs for remote controlling These open collector outputs that can sink max 300ma per output can be turned on and off remotely through a SMS You can use them to pull to ground your inputs Remote control will be reachable by sending a SMS with a certain command Note When sending normal SMS with command below the WT 1010 will turn On Off the output and reply a message of output has turned On Off to a programmable phone numbers Refer to Setting for User s Mobile Phone Number 8 SMS Center on Programming Setting page below WT 1010 User Manual Rev 2 6 IDS 6 AT ZONE1 1 Turn on ZONE1 ZONE1 ON AT ZONE3 0 Turn off ZONE3 ZONES OFF ZONE4 Green ZONES White ZONE6 Brown Inputs Connect ZONE4 ZONE5 and ZONE6 to inputs panel when there is a short circuit impulse on ZONE4 ZONES ZONE6 the WT 1010 is possible to send SMS to a programmable phone numbers For Example ZONE4 is connected to a electrical door when there is intruder or the electrical
6. lay as below SETTING gt gt gt gt gt When the terminal is ready to use it will display as below WT 1010 User Manual Rev 2 6 IDS 8 Yall WT 1010 PROGRAMMING CODE SETTING Have To Enter Password Before Start Doing The Settings Note To start with programming user must plug in a normal single line phone to TEL1 Port 1 Steps 1 Password Verification Pick up phone press X83211279 If heard du a continuous dialing tone means the Password entered correctly and then will continue to go into programming setting mode User is able to change the settings now If there is no continuous du means the Password enter not correct And it will not go into programming setting mode to change the settings User can hook on and pick up phone again to enter the Password 2 Programming Code Refer to the Programming Table below After enter the Programming Code if you heard a busy tone follow by the dialing tone it means wrong programming code If 44 heard continuous duv e it means the successful set up for that programming code If just heard dialing tone it means that the settings area are full or enter wrong programming code During the setting for the programming code user does not need to hook on the Phone When user heard dialing tone after ONE setting means the user can continue the following setting 3 To Quit from the Programming Code Setting In Hook on mode or Press ha
7. le for GSM Data Communications with the specific GSM Data receiver Modex or Quasar Power Nominal voltage 12V Dimensions and Weight LxWxH 25 x 14 x 6 cm Weight 1 5Kgs WT 1010 User Manual Rev 2 6 IDS 11 r Alarm System Environmental Specifications e Environment temperature 32 to 120 F e Relative humidity Maximum 95 Inputs and Outputs e Number of Outputs 3 e Output type Open Collector e Max current for inputs 1A WT 1010 User Manual Rev 2 6 IDS 12
8. nd free to quit from the setting WT 1010 User Manual Rev 2 6 IDS 9 No Definition Enter Password Go into Programming Setting Setting for Changing Password Setting for User s Mobile Phone number Erase User s Mobile Phone number Setting for SMS Center number Erase SMS Center number EK XK KKK KK Hi KO XXXXXXXX 7 XXXXXXXXXXXX 8 XXXXXXXXXXXX 4 Checking the GSM Service Status of W 1010 Description After Password Verification will enter to the Programming Setting Mode Initial Password for factory leaving is sets up as 83211279 Before doing this setting user will need to use the default password 83211279 to go into Programming Setting Mode to be able to use this programming code to change the password After programmed the mobile phone number the terminal is able to send Alarm SMS to alert the user notify that the PSTN line of the Alarm System has been cut off or unavailable Dial this code will erase User s Mobile Phone number from WT 1010 memory After setting SMS Center number the terminal will be able to send SMS For Example SMS Center No 1234567890 Press 8 1234567890 Dial this code will the erase SMS Center number from WT 1010 memory When the GSM link is completely lost by disconnection from the GSM network the alarm cannot be sent via GSM by WT 1010 User can always check the WT 1010 GSM Service by sending SMS to th
9. ost network WT 1010 uses the telephone line as the main transmission line and uses the GSM voice channel as backup The WT 1010 units can continuously watches if a Contact ID is directed towards the security monitoring station through the wired or GSM network and if either of the preset report codes is noticed it sends an appropriate SMS message with definable text to a mobile phone numbers Using this function the owner can get instant SMS messages not only of alarms but also every event of closing opening Sends text messages to user programmable cell phone number SMS The WT 1010 can be programmed to send a SMS to a programmable cell phone number to notify the user that the PSTN line has been cut off or unavailable Low power consumption uses 30mA while in idle state and 260mA when transmitting an alarm Wall mounting enclosure available The WT 1010 units can be installed inside alarm panel or inside its own wall mount enclosure WT 1010 User Manual Rev 2 6 IDS 3 SKETCH OF THE WT 1010 The WT 1010 GSM Alarm System Fixed Wireless Terminal Power Indicator Signal Indicator Frontal view LED INDICATORS gt LED1 Power indicator it s lit while power source is connected correctly LED1 Signal indicator Stays lit indicates that the terminal is on GSM network Stays off indicate that the terminal has failed to search for GSM network OUTPUT Connect the RS232 DB15 female cable to the termin