1. quency modules used by the thermostat and the actuator Please note that the range will decrease if obstacles are found between the CH130RF and the CH172DRF To start the thermostat after the same has been installed proceed as follows 1 Select the Summer Winter operation 2 Select the operating mode 3 Select the fan speed Summer Winter selection To switch from the Winter operation i e heat ing system to the Summer operation i e cooling system and vice versa press the 1 2 button combination The selected operation will be indicated on the display by the Winter or Summer icons w E Winter dill Summer we aTa TOP COVER __ HERMOSTAT FRONT Operating modes The CH130RF thermostat features three dif ferent manual operating modes Comfort Economy and the OFF function OFF Comfort operating mode With the Comfort operating mode the ther mostat regulates the heating or cooling sys tem operation in order to always keep the same comfort temperature set To switch from Economy to Comfort press buttons 3 and 4 simultaneously The temperature level can be modified during operation by means of buttons 3 and 4 The temperature can be changed from 2 C to 40 C by 0 1 C steps Economy operating mode With the Economy operating mode the ther mostat regulates the heating or c
2. special panels or other suitable housings The unit shall be installed by qualified person nel in accordance with the EN regulations in force The maximum communication distance be tween the actuator and the transmitter shall be 30 m in free air Connect the wires to the socket terminal block in accordance with the diagrams illustrated below If a two tube system is available connect only valve 1 contact between terminals C and V1 In case of a four tube system valve 1 is dedicated to heating whereas valve 2 be tween C and V2 is dedicated to cooling WARNING Prior to carrying out any operation on the unit make sure that you have discon nected the mains connecting cables Operation The unit operating status is indicated by the LED represented by 1 GREEN good RF signal level YELLOW poor RF signal level e RED low or poor RF signal level or signal not detected Alternating GREEN RED relay switch on manual mode Alternating GREEN YELLOW RED OFF sig nal self learning mode Five more red LEDs indicate the switch on of the corresponding relays To be able to use the CH172DRF with a CH130RF a self learning procedure shall be performed keep the CH172DRF button de pressed for approximately 5 seconds until the multicolour LED comes on by switching among green yellow red and OFF Then press the CH130RF reset button after a few instants the LED wil
3. ambient tempera ture will be shown on the display 2 set point the current set point will be shown on the display P07 ambient temperature correction It can be adjusted from 4 0 to 4 0 C This pa rameter is used to correct the acquired ambient temperature As a matter of fact the ambient temperature reading may on some instal lations not be satisfying owing to the probe location i e internal or resumption With this parameter a constant value upon reading can be added to or subtracted from P08 Winter lower limit set point tempera ture It can be adjusted from 2 0 to 40 0 C It rep resents the lower limit for all the set points Comfort and Economy in the heating mode P09 Winter upper limit set point tem perature It can be adjusted from 2 0 to 40 0 C It rep resents the upper limit for all the set points Comfort and Economy in the heating mode P10 Summer lower limit set point tem perature It can be adjusted from 2 0 to 40 0 C It repre sents the lower limit for all the set points Com fort and Economy in the cooling mode P11 Summer upper limit set point tem perature It can be adjusted from 2 0 to 40 0 C It rep resents the upper limit for all the set points Comfort and Economy in the cooling mode P14 differential adjustment It can be set staring from 0 3 C value suit able for slow inertia systems to
4. 2 C value suitable for very reactive systems Technical features of the thermostat Power supply Two AA batteries 1 5 V Outputs RF module Inputs External probe input Electric connections Screwed terminals Protection degree IP20 pollution degree 2 Setting memorization Non volatile memory Software Class A Temperature adjust o o ment range 2 C 40 C Max temperature T45 Local signalling LCD display Local controls 5 buttons Dimensions Lx Hx D 135 x 83 x 21 External temperature probe distance 10m max Reference temperature 4 K h gradient Radio signal features 868 350 MHz lt 15mW Signal max range in free air 30 m indoors 70 m outdoors Conforming to the directives 2006 95 CE 2004 108 CE 1993 68 CE Complying with the standards R amp TTE EN 300 220 3 EN 60730 1 EN60730 2 9 ErP classification ErP Class IV 2 EU Reg 811 2013 813 2013 DIN bar CH172DRF actuator Application and use An unlimited number of actuators can if nec essary be controlled by one single thermostat provided that such actuators are subjected to self learning and are placed within the maxi mum communication distance see below ee dI Ferri Coma CHITZDRF ce beg a pasata Leabib E bob sd Era mi tota S h E Je Fastening and connecting The unit has been designed to be built in in side fan coils
5. J Motor 230Vca Technical features of the actuator Power supply 230V 50 Hz Absorbed power 2VA Input Thermostat controls Relay output 5 3 A250 V features Voltage free switching contacts 2 valve outputs Network voltage switching contacts 3 motor contact outputs Receiver OOK 868 350 MHz Container IPOO pollution degree 2 Software class A Max temperature T45 Disconnection type 1B micro disconnection Pulse voltage Type of assem bling 4000V DIN bar Dimensions DIN bar 6 module container 106 x 93 x 42 mm Conforms with the directives Complying with the standards 2006 95 CE 2004 108 CE 1993 68 CE EN60730 1 R amp TTE EN 300 220 3 EN 301 489 3 Fantini Cosmi S p A reserve the right to make any necessary technical and construction modification without any obligation to give prior notice WARNING SELF LEARNING PROCEDURE SUPPLEMENT In case of multiple kits CH130 plus CH172DRF installation proceed as follows 1 Make sure that all CH130 are not powered battery out 2 Insert batteries in the first CH130 Start self learning procedure between the CH130 and relevant CH172DRF as per manual instruction Remove batteries from the first CH130 Repeat the procedure from 1 to 4 for other kits 6 When all the self learning procedure had been done with all kits insert the batteries in each thermostat and test the h
6. at teries 1 5 V It is able to drive two valves and control a 3 speed fan coil motor in manual mode The thermostat measures the ambient tem perature either through an internal probe or an external sensor It keeps the set point by act ing on the ventilation speed The wide display shows the measured tem perature the fan speed the program being run and the selected season The settings and data are stored in a perma nent memory capable of keeping the same even when the batteries are not inserted Controls and signals Controls 1 Fan speed increase button 2 Fan speed decrease button 3 Selected program temperature value increase button 4 Selected program temperature value decrease button 5 Thermostat reset button Button combinations press simultan 1 2 Summer Winter switch 3 4 Comfort Economy switch 2 4 Celsius Fahreneit switch Signals 7 3 d ttt Measured temperature Comfort symbol Economy symbol Summer symbol Winter symbol Fan speed symbols System ON in summer operation System ON in winter operation Low battery charge 0 DONDOUIDSWWNA User s manual First of all make sure that the self learning procedure has already been performed page 8 moreover verify that both the CH130 and the CH172D are 30 metres far from each other at the most In fact this distance represents the free air maximum range for the radio fre
7. at configuration allows you to customize the device operation parameters To access the configuration program proceed as follows 1 Press the Reset button and also button 3 with the thermostat ON 2 Release the Reset button then keep but ton 3 depressed for at least 3 seconds 3 Release button 3 The configuration parameters are represented by an index P01 P02 on the display by pressing buttons 1 and 2 the parameter in dexes will be scrolled through Press button 3 to enter the displayed parameter To modify the current parameter press buttons 1 and 2 To exit the parameter press but ton 3 Once all parameters have been set press button 1 until the END message appears then press button 3 Now the thermostat will save the modified parameters into the internal memory and will automatically exit the param eter menu On the contrary if buttons 1 and 4 are pressed simultaneously when the END mes sage is displayed the CH130RF s RF address will be reset and the self learning procedure shall be performed again N B The thermostat will send the switch on off controls for the three fans and the two valves to the actuator to a fixed rate of 1 minute Index Parameter Values Preset P01 END Type of system 1 2 External probe 1 2 P03 Display visualization Ambient tem perature correcti
8. eating cooling system NOTES DISPOSAL OF PRODUCTS The crossed out wheeled dust bin symbol indicates that products must be collected and disposed of separately from household waste Integrated batteries and accumulators can be disposed of with the product They will be separated at the recycling centres The black bar indicates that the product was placed on the market after August 13 2005 By participating in separate collection of products and batteries you will help to assure the proper disposal of products and batteries and thus help to prevent potential negative consequences for the environment and human health For more detailed information about the collection and recycling programmes available in your country please contact your local city office or the shop where you purchased the product iniCosmi FANTINI COSMI S p A Via dell Osio 6 20090 Caleppio di Settala Milano ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it EXPORT DEPARTMENT Ph 39 02 95682229 export afantinicosmi it www fantinicosmi com EHI ce GB79335D
9. iniCosmi RADIO FREQUENCY AMBIENT THERMOSTAT FOR FAN COILS CHISORFR TABLE OF CONTENTS Noducion si Controls and signals scio CONS ai SNAS e E i User s manual Eee een Summer Winter selection Operating modes sula ni Comfort operating Mode Economy operating mode OFE tdnclon QEB srrent Fan speed selection i Maintenance scsi lAstallatiOn e Fastening the SOCKET Electric connections crisi Fastening the thermostat onto the socket Inserting and replacing the batteries 9 CH172DRF self learning procedure 9 Thermostat configuration 10 Technical features of the thermostat 13 DIN bar CH172DRF actuator cri 13 Application and use iii 13 Fastening and connecting 14 OPE ccalaa 14 Operation CHECK 15 Technical features of the actuator 16 Introduction This fan coil thermostat control kit CH130RFR is made up of a CH130RF thermostat and a DIN bar CH172DRF actuator The CH130RF model is a fan coil 4 or 2 pipe thermostat that allows you to control the ambi ent temperature both in the heating and cooling mode These controls are sent to a CH172DRF actuator that communicates with the CH130RF through radio frequencies The CH130RF is powered by two AA size b
10. l be blinking fast and then illuminate green steadily Operation check Refer to the preceding instruction manual for the use of the CH130RF thermostat Make sure that the actuator is close enough to the thermostat 30 m in free air or less if obstacles are found Power the actuator by connecting the same with the electric mains Press the CH172DRF button the LED will switch among the green and red light to indi cate the manual mode Each time the button is pressed one or several relays will turn on this will be indicated by the switch on of the cor responding red LEDs Below is the switch on sequence 1 accessing the manual mode and valve 1 switch on 2 valve 1 switch on engine speed 1 3 valve 1 switch on engine speed 2 4 valve 1 switch on engine speed 3 5 valve 2 switch on 6 valve 2 switch on engine speed 1 7 valve 2 switch on engine speed 2 8 valve 2 switch on engine speed 3 9 exiting the manual mode Perform a self learning procedure as de scribed above Now the CH172DRF and the CH130RF will be able to communicate e Switch over on the thermostat the fan mo tor speed 3 relays and the valve control 2 relays then verify that they have actually switched over Electric connections CH130RF te p supply E V A TASTO og LI dim IEV 2 E V 1 Ee on V p supply E V B AM
11. n 3 seat boxes 503 BATTERYI COMPARTMENT E I MULTI POLE__ CONNECTOR 60 0 DRILLING CENTERS Remove the thermostat top cover Separate the thermostat socket and front by removing the screw by means of a suitable tool and taking the front part off Fasten the socket to the desired surface by means of the special fastening holes make sure that the socket is properly engaged with no deformation and that the connecting multi pole connector is located in the right bottom corner To ensure correct operation the socket shall be placed at a height of approximately 1 5 me tres from the floor far from heat sources direct sunlight etc and doors windows Electric connections External probe connection Connect the two external probe wires with screwed terminals 1 and 2 as illustrated in the figure Such probe can be configured as external probe or minimum temperature con tact See the thermostat configuration para graph P02 parameter Fastening the thermostat onto the socket Insert and screw the thermostat down to the socket make sure that the multi pole connec tor is engaged correctly Inserting and replacing the batteries Insert two AA batteries 1 5 V into the battery compartment according to the correct polarity the negative pole shall press the metal spring located on the right when viewing the ther mostat from the front Fit the battery top cover back into
12. on Winter lower limit set point temperature Winter upper limit set point temperature Summer lower limit set point temperature Summer upper limit set point temperature Thermostat saving and reset 1 Mae 4 C 4 C step 0 1 C 2 C 40 C 2 0 C step 1 C 2 C 40 C 40 0 C step 1 C 2 C 40 C 5 0 C step 1 C C C 2 C 40 30 0 C step 1 C Differential 0 3 2 C 0 3 C adjustment 11 P01 Type of system 1 two tube system the thermostat will drive only the valve ON OFF type used for heat ing both during the heating and the cooling in fact the valve will control both hot water and cold water 2 four tube system the thermostat will drive one valve ON OFF type used for heating plus one additional valve ON OFF type used for cooling depending on the needs of the en vironment P02 External probe 1 not available with this version 2 not available with this version 3 minimum window thermostat contact when the contact is open the thermostat will carry out heat regulation when it is closed the heat regulation will not be carried out 4 inverted minimum window thermostat con tact the window contact will operate with an inverted logic with respect to the statements made in previous step 3 5 none the external probe input will not be controlled by the thermostat P03 display visualization 1 ambient temperature the
13. ooling system operation in order to always keep the same economy temperature set To switch from Comfort to Economy press buttons 3 and 4 simultaneously The temperature level can be modified during operation by means of buttons 3 and 4 The temperature can be changed from 2 C to 40 C by 0 1 C steps OFF function OFF The OFF function can be achieved by setting the fan speed to zero in this case the thermo stat will carry out no heat regulation not even the antifreeze one The system will switch off automatically and the OFF message will appear on the display Fan speed selection The fan speed can be set either to three fixed levels minimum medium maximum by pressing buttons 1 and 2 Maintenance The thermostat should be cleaned by using a soft cotton cloth No detergent should be used Installation arning The thermostat shall be installed only by qualified personnel in strict compliance with he law regulations in force The thermostat installation involves carrying out the following operations e Fastening the socket e Making the electric connections Fastening the thermostat onto the socket e Inserting and replacing the batteries Configuring the thermostat parameters Fastening the socket The thermostat is supplied complete with a socket suitable for mounting both on the wall and to rectangular or round built i
14. place A pair of new batteries will normally last one year at least WHEN THE low battery charge SYMBOLAPPEARS ON THE DISPLAY BOTH BATTERIES SHALL BE REPLACED CH172DRF self learning procedure In order for the CH130RF and the CH172DRF to be able to communicate correctly a self learning procedure shall be performed During this procedure the remote actuator will recog nize and store the CH130RF identity from now on it will be able to perform all of its controls while leaving out the controls from other trans mitters that might be found in the area please note that the CH130RF CH172DRF system range is approximately 30 metres in the free air To perform self learning proceed as follows keep the CH172DRF button depressed for at least 5 seconds until the multicolour LED comes on by switching among green yellow red and OFF Then press the CH130RF reset button after a few instants the LED will be blinking fast and then illuminate green steadily to indicate that the self learning has occurred this procedure is also described in the CH172 DRF instruction sheet N B You can also control two or several CH172DRF actuators by means of one single CH130RF of course the self learning proce dure shall be performed on all the CH172DRFs it shall not necessarily be performed at the same time Thermostat configuration arning The configuration shall be performe only by qualified personnel The thermost

Download Pdf Manuals