1. OFF NC 5 4 MECHANICAL REGULATORS TIMER W time adjustment of the barrier reverse movement after the limit switch was activated AUTO CI adjustment of pause time before automatic closing of the barrier Pause time is adjusted within the interval of 0 70 seconds Automatic closing function is off if the regulator is in the end left position Turning the regulator right increases the pause time before automatic closing FORCE adjustment of operator s pulling force setting of maximal consumption current If the regulator is in the end right position the operator force is maximal not recommended Adjustment of mechanical regulators WARNING If you change a mechanical regulator position turn off and then turn on the barrier supply voltage Otherwise the changes won t take effect Turn the corresponding regulator clockwise to increase the setting Turn the corresponding regulator counterclockwise to decrease the setting aq lt TIMER AUTO CL FORCE a 6 PROGRAMMING OF REMOTE CONTROLS 1 Memory cleaning After power supply is on hold down the CODE button for 10 seconds The A indicator will glow for 10 seconds then it will blink twice and go out to confirm that the codes have been erased 2 Control s code storing To store the code of the remote control press and hold down for 3 seconds the CODE button The red A indicator will glow Release the button Select a button on t
2. Return in the starting position was not executed Turm the release lever in midposition refer to Release operation Sudden stop of the barrier Force protection is activated Adjust the barrier force The boom lifts or lowers in jerks or stops suddenly The boom is not balanced Adjust the balancing spring The boom does not open close fully Wrong adjustment of the limit switches Adjust the limit switches 11 DOORHAN We very much appreciate that you have chosen the product manufactured by our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Republic Telephone 420 474 319 111 E mail europe doorhan com www doorhan cz
3. signal from these devices If the barrier does not move and the sensors connected to these terminals are actuated the barrier will not move To connect several devices with NC contacts connect them in series WARNING If no devices are connected to these terminals place a jumper between the contact terminals EMRG see the wiring diagram 7 24 V DC output terminals on 24 V DC power supply transformer max load is 600 mA 5 3 DIP SWITCHES DIP1 operation mode The Start command have no effect during the gate opening on off if DIP1 is in ON position DIP2 individual control If DIP2 is in ON position you can realize individual control i e the device connected to Start terminal sends an opening command and the device connected to Ped terminal sends a closing command on off DIP3 this DIP isn t used DIP4 limit switch DIP4 on off NO NC Com PROGRAMMING OF REMOTE CONTROLS Adjustment of DIP switches WARNING If you change a DIP switch position turn off and then turn on the barrier supply voltage Otherwise the changes won t take effect DIP switch DIP switch function DIP switch position Function realisation l ON No DIP1 Operation mode the barrier stops after the START command has been sent OFF 7 es a Individual control START command opens the barrier PED command closes OFF No the barrier ON Yes DIP3 The DIP isn t used ON NO DIP4 Type of limit switch contacts
4. teens 7 bids DIPSSWICHOS 0 0 es0t 046s seete oe ees Ghee teehee Ree oreo bs Cathe eRe eee deeb doko tad eed sede eee 9 6 PROGRAMMING GF REMOTE CONTROLS cncacawad einen eak wie saw dade oa ew Saw canad gia cada doe ade cares 10 Ta RELEASE OPERATION a ink dictate aa axe siie ak feat ded ark inona diane eae ee an iani Gidea eek ded ark dred ark man dk a 11 8 MAINTENANCE ics cedu ciao gh nh wae Pe Sa se d Gaon WOR DOR Naw ddan Beek Chek Weed ddan Hans Glau ween geen he 11 9 TROUBLESHOOTING sis asrnane ict ivtebereenea biel teba caedetasin dela a aAa Ea aai 11 1 GENERAL INFORMATION Barrier is an ideal solution for managing access points in residential and industrial areas when traffic volumes are medium and high It suits for passage clearances of up to 6 m The barrier cabinet has only one spring if the boom length doesn t exceed 4 m If the boom length is 6 m a second spring should be installed The boom should be balanced irrespective of its length The cabinet encloses a motor a reduction gear a boom fastening unit a balancing mechanism magnetic limit switches and a control board in a separate casing The boom is made of aluminium profile with red light reflectors which are easy to see in the dark The system ensures fixation of the boom in any position that s why manual opening is possible only if the system is released A signal lamp is blinking when the boom moves 1 2 SPECIFICATIONS Parameters Charac
5. DOORHAN BARRIER BARRIER _ Installation and Operating Manual DooHan 2012 CONTENT GENERAL INFORMATION SAFETY INSTRUCTIONS BARRIER UNIT INSTALLATION ELECTRICAL CONNECTIONS PROGRAMMING OF REMOTE CONTROLS RELEASE OPERATION MAINTENANCE TROUBLESHOOTING 10 11 11 11 CONTENTS CONTENTS 1 GENERAL INFORMATION cca cc0 ne os GXi0 wa ok Galok aioe tekae we daiwa sae EE awe Sawa Saou Hed ween Geek wae 2 Ie Specifications eesis irane draa a eae ED indus ine AAE D der aa A a Raa ED Baa a E N 2 1o Barnorpackago se rea e E a a a teas a a a a cee aree 2 2 SARETY INSTRUCTIONS ociscene anaa Sead Raa En A Ras KERE Rains an EAE GEA A E AN Race E RNa EA 3 S BARRIER UNIT sis arre nese nenes eae duck aee e aeae eiae shaw aha e e aa ae eaaa a aeia 4 4 INSTALLATION 32tctrc averde state deed edad d a a a S 4 Ale WOOIS a e aeo aar aa aD Ea ahs ea EAE a E ae eee ees EE E once EA E nae oe OR E Ss Ate a a ee 4 42 Installati n guidelines niia beceeiie ce n ie oA ea Pee E EE E E E A E E es Wd 5 Aa HBOOM MStAlAUOM eee ana ese a Se S VAE E e SES E g A Heo OAU E E E gees 5 4 4 Adjustment of the end boom positions 0 0 s anaia TE ea 6 y REE PMU PLC COIN TOSI aca sadet ast acne ae eA a in Ono ar whch E a wen aa a aod aa 7 5 1 Control DlOck WINIMG ClaQhaM 6 2 sen se aide wth eos Sek es E a oes eR So a dks TE A es ee 7 5 2 Description of the control block elements 0 0 cece cette tenet
6. ace 4 3 BOOM INSTALLATION Remove the cabinet casing panel e Unlock the release for release operation see par 7 Direct the boom in accordance with opening direction Install and adjust the balancing springs using tension and insert it in the U shaped fastening bracket bolt so that the boom remains stationary in any position Put on the second U shaped bracket on the boom when the operator is released as shown in the picture e Resume the normal operation having blocked the Place and fix 4 fastening bolts release INSTALLATION 4 4 ADJUSTMENT OF THE END BOOM POSITIONS 4 4 1 Closed position adjustment 4 4 2 Open position adjustment A A Make sure that the barrier is fixed rigidly close the N D O p i s y Adjustment screws barrier Loosen the closed position adjustment screw CL Move the screw in the slit until the limit switch is activat ed control activation using the indicator on the control block Fix the screw in the slit having tightened the fasten ing nut m f Lift and lower the boom to make certain that the de Oe Sarr amp celeration limit switch works properly Make sure that the barrier is fixed rigidly open the barrier Loosen the open position adjustment screw OP Move the screw in the slit until the limit switch is activated control activation using the indicator on the control block Fix the screw in the
7. cessories 24 V 600 mA 24 V Positive contact of power supply for accessories 24 V 600 mA Sw Op Control contact of open limit switch Sw CI Control contact of close limit switch EMRG Pair of emergency stop contacts NC Ph Op Control contact of open photocells NC Ph CI Control contact of close photocells NC Ped Close command DIP2 is on NO Start Open or stepped control command NO Control block LEDs Indicator Function Glows Does not glow PWR Motor supply voltage Yes No A red Add remote control code Yes No B green Emergency conditions Yes No ST START command Yes No RED PED command Yes No Ph1 Close photocells Not actuated Actuated Ph2 Open photocells Not actuated Actuated STOP STOP command Yes No Swi Close limit switch Closed Actuated Sw2 Open limit switch Closed Actuated State of the light diodes when the barrier is stationary in the middle position is shown in bold Electrical connectors 1 220 N L PE connector on the control block used for connection to supply voltage unit PE earth connection N power supply neutral L power supply phase 2 MOTOR N L1 L2 connector on the control block used for connection to electric motor unit Make sure that the motor is connected as shown in the wiring diagram 3 LAMP connector used for connection of signal lamp 230 V max 40 W It works by any move of the barrier The lamp blinking period is 0 5 1 sec Low voltage contacts used f
8. ctures without agreement with DoorHan It is highly recommended to use DoorHan optional equipment as the accessories produced by other manufacturers can damage the automated system The manufacturer reserves the right to modify the design of the product described in this manual without preliminary notice The content of the Manual shall not be basis for any claim WARNING RISK OF INJURY Have a qualified technician lay the cables 230 V AC The cables must be laid in protective corrugated tubes In case of supply cable damage use the suitable type of the cable Cables needed for installation of Barrier and accessories if available Cable 20 5 mm photocell transmitter Cabel 40 5 mm photocell receiver Cable 3x 1 5 mm power supply The cables should be appropriately insulated Coc BRIER UNIT 3 BARRIER UNIT 1 Logo plate 1 2 Hex bolt 3 Boom cover 10 4 Hex bolt 5 Boom fastening plate 9 6 Boom 7 Cabinet 8 Side cover 9 Control block 7 10 Cabinet top cover 11 LED lamp 6 5 4 3 2 1 up to6m e a E 2 AA e a 300 mm 4 INSTALLATION 4 1 TOOLS 1 Set of spanners 4 Set of drills for concrete 7 Electric drill 2 Set of slotted and cross screwdrivers 5 Pliers 8 Tape measure folding rule 3 Set of drills for metal 6 Hacksaw for metal CoN TALLATION 4 2 INSTALLATION GUIDELINES Follow the directions given below to install
9. he remote control which you will use to control the unit and press it twice The red A indicator will go out to confirm that the codes have been stored 3 To add several remote controls repeat the procedure of code storing for them You can add 60 remote controls 4 If no control commands are given the system will automatically exit from the waiting mode in 10 seconds Should the control block disconnect from the mains the programmed data will be stored 10 7 RELEASE OPERATION e Use the lever of the integral release to release the barrier e After release is completed the boom can be opened and closed manually In order to lift or lower the boom in case of a power failure do the following e Turn the release lever See the picture clockwise up the stop e You can lift or lower the boom by hand In order to enter automatic control mode of the barrier do the following e Turn the release lever in the mid position e Lift and lower the boom using the operator 8 MAINTENANCE mom o o o o o o i E M A e The Barrier automatic system does not require any special servicing e Repairs may be carried out only by a qualified technician trained and certified at an authorized DoorHan centre e Be sure that after completion of installation the installer has shown the user how to release the barrier in case of emergency and has given instructions on proper operation and maintenance of the automated system e When carryi
10. itches means that the barrier is in the end open closed position and must not move in this direction any more 4 Ph Cl contacts for connection of close safety devices NC Actuation of these devices will cause immediate reverse of the barrier until full opening Actuation of the devices connected to these terminals does not effect operation during opening of the barrier If the sensors connected to these terminals actuated when the barrier is open the barrier will not close To connect several devices with NC contacts connect them in series WARNING If no devices are connected to these terminals place a jumper between the contact terminals Ph CL and see the wiring diagram 5 PhOp contacts for connection of opening safety devices NC Actuation of the devices causes immediate stop Actuation of the devices connected to these terminals does not effect the operation when the barrier closes If the barrier is closed and sensors connected to these terminals actuated the barrier will not open To connect several devices with NC contacts connect then in series WARNING If no devices are connected to these terminals place a jumper between the contact terminals Ph Op and see the wiring diagram 6 EMRG contacts for connection of emergency stop devices NC These connections are used to protect the barrier when it opens and closes Any operational logic of the control block enables immediate stop of the barrier after the
11. ng out maintenance it is recommended to use DoorHan original spare parts RELEASE OPERATION y e Carry out maintenance of the automatic system at least every six months Regularly check if the boom moves smoothly when automatically operated Regularly check if the extreme positions of the boom travel are properly adjusted and safety devices are in good working condition e In case of power failure the barrier will stop As soon as power supply is restored you can control the barrier as usual e After expiration of life time the item shall be delivered in a specialized disposal point e If you have lost this Manual you may request for the duplicate copy to the following address Kralovsky VRCH 2018 Kadan 43201 Czech Republic or by email europe doorhan com e The producer DoorHan does not supervise the installation of operators or carry out their maintenance thus DoorHan cannot be held liable for safety of installation operation and maintenance of the equipment 9 TROUBLESHOOTING Symptom The barrier does not work Possible reason Electric power is disconnected Solution Make sure that electric power is on Boom movement is restricted Remove the restriction Bad connection of electric wires Check wires connection The barrier is released Engage the barrier After the release has been used the barrier does not work even after pushing the buttons of control station or remote control
12. or accessories 1 START full opening command NO Closing of contacts of the device connected to this terminal will cause actuation of control block for full open and or close of the barrier the exact logic depends on position of DIP1 switch DIP1 off The commands are produced in the Open Stop Close Stop cycle mode DIP1 on The commands are produced in the Open Close Stop Open mode there will be no stop at the moment of move control block will take the Start command in 1 2 sec after its previous receipt on the input Cor EEL CTRICAL CONNECTIONS If you need to connect several devices connect the normally opened NO contacts of these devices parallel 2 Ped pedestrian passage command NO DIP2 off The Ped command allows you to open the barrier by approximately 1 m After the repeated command the barrier will close If the Ped command is followed by the Start command control block will produce the command for full close of the barrier When DIP2 is off the Ped command will open the closed barrier by 1 m and will close the opened barrier DIP2 on Individual control of the operator that is the Start command will open the barrier and the Ped command will close the barier To connect several devices you should connect the normally opened NO contacts of these devices parallel 3 SW OP SW CL signals from the limit switches of barrier end positions Actuation breaking of contacts of SW OP SW CL limit sw
13. slit having tightened the fastening nut Lift and sink the boom to make certain that the deceleration limit switch works properly WARNING After the end boom positions are adjusted make sure that the end switches work properly after actuation of the swithes a corresponding indicator on the control board should go out If the indicator doesn t go out carry out the adjustment procedures again WARNING The following procedures should be performed by qualified personnel only Incorrect actions may cause irreversible damage to the equipment Don t perform the following procedures unless in a case of emergency If the boom does not reach vertical or horizontal positon adjust its position with the pull rod located inside of the cabinet Loosen nuts Rotate the pull rod counter clockwise in order to lift the boom In order to lower it rotate the pull rod clockwise Tighten nuts in the required position Check vertical and horizontal positions of the boom If required repeat the adjustment 5 ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS 5 1 CONTROL BLOCK WIRING DIAGRAM gt WARNING Always disconnect electric power before making any operations with control board connection maintenance The power cables must be laid separately from signal cables To reduce induced noises use cables with screened armature Cable wires must be protected from contact with rough and sharp parts In order to protect electric elements from moist
14. teristics Maximum boom length 6m Maximum opening time 6 sec Supply voltage 230 V 50 Hz Boom type rigid Use intensity at 20 C 70 Motor rotation speed 1400 rpm Thermal protection 120 C Working temperature range 40 4 35 C Rated power 300 W Protection class IP54 1 3 BARRIER PACKAGE Upon receiving the barrier unpack it and inspect visually Make sure that the barrier is not damaged If any damages are found please contact your supplier The barrier components included in the standard package are listed in the following table SAFETY INSTRUCTIONS Neo Name Quantity 1 Cabinet with integral control block 1 pc 2 Boom 1 pc 3 Key switch 1 pc 4 User manual 1 pc 5 Photocells 1 pair 6 V holder 1 pc 2 SAFETY INSTRUCTIONS WARNING IMPORTANT SAFETY INSTRUCTIONS It is important for the safety of persons to follow safety instructions Save these instructions Follow all instructions since incorrect installation can lead to severe injury Barrier was designed for managing access points in residential and industrial areas when traffic volumes are medium and high It suits for passage clearances of up to 6 m Do not use the barrier for other than intended purposes Installation must be performed in accordance with the standards EN12453 and EN 12445 For countries which are not EC members these requirements are to be met Prior to installation check that the location of barrier installation is suitable b
15. the barrier properly Enter the guarded territory and choose the place for the barrier cabinet Make sure that nothing impedes the boom s travel i e tree branches and a safe clearance distance of at least 2 m is provided between the tip of the barrier boom and the overhead power lines If the barrier has no protection against accidental damage caused by passing by automobiles install an additional protection means if it is possible The cabinet must be installed on a concrete mounting surface If the surface isn t strong enough make a foundation pit and concrete it Before concreting reinforce the foundation pit and lay separate conduits for the power supply and control lines AS soon as the concrete has sufficiently hardened the barrier housing must be installed The cabinet should be fixed to the foundation with anchor bolts or embedded concrete fittings The depth of concreting depends on the ground type and depth of frost penetration The ground must be stable Otherwise increase the depth of the foundation pit according to recommendations of the specialists Make sure there are no pipes and or electric cables running through the foundation pit Direct the cabinet and level it with the building level mark and drill the bore holes for the anchor bolts Install the cabinet and tighten the anchor bolt nuts as shown in the picture Cabinet Anchor bolts 4 M16 A Mounting surf
16. ure tighten the waterproofing reducing coupling of the cable input having turned the plastic nut Connection of photocells for close If you use DoorHan PhotoCell photocells put the jumper in NC position Connection of photocells for open If you use DoorHan PhotoCell photocells put the jumper in NC position Radio receiver Timer W Fuse 220 N S yi LAPE SSN Capacitor Yellow Green Jumpers N gt gt Lamp Led Limit switches Observe the polarity External control key 5 2 DESCRIPTION OF THE CONTROL BLOCK ELEMENTS Control block elements Element Description TR1 Transformer J1 Connector for quick connection of radio receiver DIP Group of DIP switches FUSE High voltage part fuse FUSE2 Polyswitch TIMER W Time regulator of the barrier reverse movement after the limit switch was activated AUTO CL Regulator of pause before automatic close FORCE Pulling force regulator Qor ELECTRICAL CONNECTIONS Control block connectors Connector Description 220 N L PE Supply voltage Motor N L1 L2 Connector for motor connection Lamp Connector for connection of signal lamp see the diagram Negative contact of power supply for ac
17. y its climatic conditions to technical specifications of the operator Turn off the power supply before installation and maintenance Earth properly all metal elements of the barrier Check mains power for compliance with the requirements stated in this manual Mains supply shall be connected to the automatic system via automatic switch with a minimal distance of 3 mm between the neighboring contacts It is recommended to use a 6A automate Safety requirements must be observed when displacing the equipment Use the tools specified in section Tools of this manual When drilling holes use protection for hands and eyes For fastening of the item use hardware supplied with the barrier or other analogous one Do not make any changes in the automatic system not specified in this manual Remove package of the item and dispose of it Keep the package materials away from children Never permit children to operate or play with the barrier control push buttons or remote controls Always keep remote controls out of reach of children Do not go or drive under the moving boom Do not impede barrier moving DoorHan shall not be held responsible in case of injury caused by misuse of the product DoorHan shall not be held liable in case of improper installation of the item and damage arisen during operation DoorHan is not responsible for unstable work of the automatic system when using safety devices and accessories which are produced by other manufa