Home
        WL-UU551 User manual
         Contents
1.   i w        m       gt  iy  Sw i u         connecting sockets    MYCHWAY iz     PATENT REGISTRATION PIRATED RESERVED    Accessories       40k cavitation head Sixpolar RF   Laser       Tripolar RF Head Bipolar RF       Vacuum   Multipolar RF    Basal Operation  1 Put all the accessories well and connect them to the  host     Insert the Sixpolar laser RF work head to  A    2 Insert 40k cavitation work head to  B    3 Insert Tripolar RF work head to  C    4 Insert Bipolar RF work head to  D     2  Insert power supply to  F   Turn on general power  switch  E        Interface LCD screen       40k cavitation Explode Procedure   Apply the cavitation theory  use the 40Khz Ultrasound to make intense vibration   which causes a  inner explosion in the fat issues   thus get rid of lipocyte  it can effectively break down stubborn  and deep fat  decrease lipocyte quantity and its size    The diathermal of the low frequency ultrasound can promote lipocyte and tissues liquid flow   which help drainage of fatty acid  waste and toxin through lymph system    1  Clean the parts and applied gel on fleshly parts  e g abdomen hip  thigh   the amount depend  on moving flexibility of the cavitation explode     1  Click the  lt I gt   to choose the mode 40k cavitation    time mode and energy will be displayed   2  Energy adjust  Click  lt 4 gt   lt 5 gt  for adjusting energy   lt 4 gt for decreased   lt 5 gt  for increased     3   Time adjust  Click  lt 2 gt   lt 3 gt  for adjusting energy   lt 3 gt 
2.  click  lt 1 gt   to choose the mode which you like  When we do every mode  we can click  lt 6 gt  to let the  laser light turn on and off   4  Set works time  20 minutes for each parts  5 The system default laser is start state   click  lt 6 gt   the laser function is closed    Note Do not let the laser light straight shine upon the eyes in case of eyes hurt  6 Applied gel on skin needed nursing   the electrode probe move slowly on skin  if there is  too much fat   you can increase the output intensity   7 The machine will pause automatically if the setting time 1s over      8  Clean the leftover with hot towel use warm towel to clean the work head     Bipoar RF head for eye    1  1  Click  lt 1 gt   Adjust the mode to Bipolar RE    2  Energy adjust  Click  lt 4 gt   lt 5 gt  for adjusting energy   lt 4 gt for decreased   lt 5 gt  for increased    3   Time adjust  Click  lt 2 gt   lt 3 gt  for adjusting energy   lt 3 gt for decreased   lt 2 gt  for increased    4   Mode Transfer Click  lt 6 gt  first   make it to the interface for mode transfer   then click  lt 1 gt   to choose the mode which you like  When we do every mode   2 Set works time  20 minutes for each parts  3 The system default laser is start state   click  lt 6 gt   the laser function is closed   Note Do not let the laser light straight shine upon the eyes in case of eyes hurt  4 Applied gel on skin needed nursing   the electrode probe move slowly on skin  if there is  too much fat   you can increase the output
3.  intensity   5 The machine will pause automatically if the setting time is over      6  Clean the leftover with hot towel use warm towel to clean the work head     Caution for RF   1 Beautician should wear insulated gloves during operation    2 Do not wear any aglet both for the beautician and the users   3 The electrode probe must be fully in contact with skin    4 Do not make the RF electrode stay on any part without moving  Keep it moving on skin   slowly    5 Skin around eyes and forehead is very thin  the RF output intensity should be relatively   weakened    6 Do not contact skin with unipolar when using of bipolar   tripolar  hexpolar work head  otherwise it will produce pulse discharge  gel paste  Ect  Products like gel maybe evaporated  into a mist     7 Do not let the laser light straightly shine upon the eyes in case of eyes hurt     Vacuum Multipolar RF  1  1  Click  lt I gt   Adjust the mode to Vacuum    2  Energy adjust  Click  lt 4 gt   lt 5 gt  for adjusting energy   lt 4 gt for decreased   lt 5 gt  for increased    3   Time adjust  Click  lt 2 gt   lt 3 gt  for adjusting energy   lt 3 gt for decreased   lt 2 gt  for increased    4   Mode Transfer Click  lt 6 gt  first   make it to the interface for mode transfer   then click  lt I gt   to choose the mode which you like  When we do every mode   2 Set works time  20 minutes for each parts  3 The system default laser 1s start state   click  lt 6 gt   the laser function 1s closed   Note Do not let the laser light
4.  straight shine upon the eyes in case of eyes hurt  4 Applied gel on skin needed nursing   the electrode probe move slowly on skin  1f there 1s  too much fat   you can increase the output intensity   5 The machine will pause automatically if the setting time is over      6  Clean the leftover with hot towel use warm towel to clean the work head     Forbidden Group  1  People with heart disease or high blood pressure   or configured cardiac peacemaker    2 Patients with acute inflammation  asthma deep vein thrombosis  thyroncus    cancer   3 People with hemorrhagic disease   trauma or who is bleeding   4 Pregnant women  5 Medical Plastic parts   or parts with artificial in filling inside   6 People with metal inside the body  include metallic tooth   7 Patient with skin inflammation or with edema   8 People with an abnormal immune system     9 Numb or intensitive to heat     Technical Specification    Screen 5 4  Color TFT Display  Rated input voltage AC220V 240V 50HZ  ACI10V 120V 60Hz  Rated input power 350VA    Cavitation frequency   40KHz  Cavitation Power up to 60W    Cavitation tip 60mm diameter    RF for body   RF frequency 3MHz  RF power up to 150W  RF type six polar   RF tip 65mm diameter    RF for face   RF frequency  1MHz  RF power up to 100W  RF type tripolar   RF tip 25mm diameter    RF for eye   RF frequency 1MHz  RF power up to 60W  RF type bipolar   RF tip 25mm diameter    Lipolysis laser 635nm    Lipolysis power  100mw    Photon   Light Red LED light  Wavelengt
5. WL UU55      User manual       Catalog    WAI  coaens one cae ean renee Tee  Parts instruction       Accessorles      cece ea aa aa aa aa a eee eee ee eee ee    Bascal  T eT h   u pesa aduana bat di eee e wete 5    AQkedvi tation  Explode procedure          eeunenn 5  Cautron  Tor Sti AK  e ose Lak iii iL ree RUS eee 6  Cal Oracion Tor AOR  a re pe je av ja ee 6  ST EDO lar R WOR DOO E aa rena   a boat ene  SAS Bed 6  dbs canta Doe AR WOR LOO renate rad ee NG T  Bipolar    Ab Or ON TTT 8  Caution Tor MSN RP vann Sree cred dete ea ete ee as dh O  Forbidden voj o Re m mph a ramena a 8  Teenmnicialk  parameters  smb neee nea eR Re eae 9  PAC NO  MS GLA vaneen eee AN ae Ras ew iga mt 9  PAO sea dk sk is end s DESI rena   a bo doii 10  Warning    Dear user    Thanks for using our company s products  in order to fully make use of the    products   we sincerely suggestion follows     1  Please read the instruction in detail and keep it well for further reading and  consulting     2 Please follow the instruction to fit and operate the machine correctly     3  Please do not remove and change any accessories of the machine    4  It forbids others to open and remove the mainframe except the authorized people  in the company     5  It forbids others to change and maintain the machine except the professional  people     6  Please contact us if there is any trouble during operation     Parts Introduction        ia    elt Tn  of 176176089  H E  HEL  E lt   lain le i T     f a m KEF     5 i 
6. ays to do the treatment     Sixpolar RF for body   1 Click  lt I gt   Adjust the mode to Sixpolar RE     2  Energy adjust  Click  lt 4 gt   lt 5 gt  for adjusting energy   lt 4 gt for decreased   lt 5 gt  for increased    3   Time adjust  Click  lt 2 gt   lt 3 gt  for adjusting energy   lt 3 gt for decreased   lt 2 gt  for increased      4   Mode Transfer Click  lt 6 gt  first   make it to the interface for mode transfer   then click  lt I gt     to choose the mode which you like  When we do every mode  we can click  lt 6 gt  to let the  laser light turn on and off   2  Set works time  20 minutes for each parts  3 The system default laser is start state   click  lt 6 gt   the laser function is closed   Note Do not let the laser light straight shine upon the eyes in case of eyes hurt  4 Applied gel on skin needed nursing   the electrode probe move slowly on skin  if there is  too much fat   you can increase the output intensity   5 The machine will pause automatically if the setting time is over      6  Clean the leftover with hot towel use warm towel to clean the work head     Tripolar RF head for face    1 Click  lt 1 gt   Adjust the mode to Tripolar RE    2  Energy adjust  Click  lt 4 gt   lt 5 gt  for adjusting energy   lt 4 gt for decreased   lt 5 gt  for increased    3   Time adjust  Click  lt 2 gt   lt 3 gt  for adjusting energy   lt 3 gt for decreased   lt 2 gt  for increased    4   Mode Transfer Click  lt 6 gt  first   make it to the interface for mode transfer   then
7. for decreased   lt 2 gt  for increased     4   Mode Transfer Click  lt 6 gt  first   make it to the interface for mode transfer   then click  lt I gt  to  choose the mode which you like  When we do every mode  we can click  lt 6 gt  to let the laser light  turn on and off    2 Beautician hold the cavitation explode work head to move slowly on skin  in circle or  beeline repeatedly   and the other hand push the fat towards the work head    3 Do not use on back  avoid using on bones    4 Do not use on uterus part when a woman do abdomen treatment during menstruate should be  avoid     5 The machine will pause automatically if the setting time is over   Please click any place the  screen according to the hint    6 Clean the leftovers with the hot towel    use warm towel to clean the cavitation explode work  head     Caution for using 40k   1 Applied enough gel on skin need treated   2 Do not stay unmoved on any part of your body   do not stay on bones    3 The total treatment time for daily should be within 30minutes    4 There will be ultrasonic only when you start the working mode of 40k    5 Do not allowed to be placed under the state of no load to avoid the damage caused by high heat   6 40k work head can be used on fresh part of the body  Do not use for facial   If the skin is    sensitive or becomes unhealthy    Calibration for 40k  1  We can click the  lt l gt and  lt 6 gt  to calibrate the frequency of 40k cavitation head  so that get the    best result and comfortable w
8. h 640nm  5nm  Power  15W    Packing Include   Main maichine x1 unit   40KHz cavitation head x lunit  Sixpolar RF head for body xl unit  Tripolar RF head for face x lunit  Bipolar RF head for eyes x lunit  Power supply wire x lunit  Holder x lunit    Key switch x 1 unit    FAQ    1 How quickly will I see the results of treatment    Most clients experience few cm of reduction in circumference after a single session  with  increasing results after each visit  The results may vary with different tissue structure  treatment  area  age  metabolism  medications  and changes in hormones  Proper diet and increased physical  activity will certainly improve and help to maintain the results     Between 8 and 12 sessions  you will be able to appreciate the results from the third session on     2 Is repeat treatment required    Generally  one treatment per a single area is usually adequate to achieve the required results  And  we suggest that you had better have 8 and 12 sessions    Normally it is a Long lasting treatment     However  maintenance of this fat loss is dependent on a healthy diet and exercise     3 How does it feel    Most clients consider the procedure painless and comfortable There may be  however  a slight  discomfort due to the specific noise experienced  but it poses no harm and disappears as soon as  you are not in contact with the applicator  You may also experience a little warmth during the  treatment    It is very normal if you experience with this aboved problems i
9. n which is doing the treatment of  Real 40Khz cavitation     
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung VC240 Εγχειρίδιο χρήσης  Betriebsanleitung Mode d'emploi Gebruiksaanwijzing  StarTech.com 5.25” USM Storage Bay with 2.5” SATA USM / USB 3.0 Hard Drive Enclosure  WIRELESS PRESENTER with FLASHLIGHT  La lecture et l`écriture en centre de loisirs  特記仕様書(施工条件明示一覧表)  Quadrifoglio B Manual  Hama 00105373 padlock  ITNS-500 - Innovative Technology    Copyright © All rights reserved. 