Home

Quick start guide

image

Contents

1. Priority for alarm variables only sets the priority for alarm management on the supervisor values supported Technical Very High High Medium Low Number of decimals number of decimal numerals Sign if enabled the variable will be displayed with the or sign 1 signed 0 unsigned Maximum value maximum value of the variable Minimum value minimum value of the variable Unit of measure unit of measure to be displayed next to the variable Modbus read function Coil or Digital Input for digital and alarms Holding or Analog Input for analogue and integer Modbus write function Single Coil for digital and alarms Single Holding for analogue and integer Read write defines the type of access allowed to the variable read only or read write Access level possible values OEM service and user where each group includes the following one in the order stated Used to create groups of variables and limit their visibility based on the access level of each user Linearisation parameters A value and B value the variable value will be calculated as y a x bj where x is the sampled value and y the value indicated in the portal tERA 030222141 rel 2 5 16 06 2014 8 Display attribute only available when using an Excel file to create the template establishes whether a variable is considered a favourite and therefore displayed in the corresponding section Home Main Stat favourite Thresholds
2. attribute only available when using the editor on the portal to create the template See the section on Alarm management by threshold 3 2 3 Alarm management by threshold An alarm can be generated and notification sent when the value of a certain analogue or integer variable changes To do this simply complete the Thresholds section in the template for the variable in question For each variable the following can be set Low threshold Low threshold hysteresis High threshold High threshold hysteresis When the value of the analogue or integer variable falls below the low threshold or exceeds the high threshold an alarm is activated the event ends when the value rises back above the low threshold hysteresis or falls back below the high threshold hysteresis ALARM REENTER t 3 LP be br ALARM FIRED d L i Mirna 20 5 Hyst 1 5 wen ALARM FIRED Y 3 ES 20 5 ra an ALARM REENT ER bung 8 Li Sj ALARM FIRED d 4 ALARM FIRED ent 3 tERA 030222141 rel 2 5 16 06 2014 9 3 3 Plant configuration Access Administration go to the Plants section click new and complete the fields All the data and any notifications relating to the installation refer to the time zone set here The communities field is used to set the limits for accessing the installation see the Communities section The installation can be associated with multiple communities The install
3. gt lt div gt lt a href div livingroom class row link gt lt div class row container right row gt amp rsaquo lt div gt lt a gt lt section gt lt div class main btn gt lt a href div index gt lt img src S IMG main icon png gt lt a gt lt div gt lt div class variable btn bedroom var placeholder data line ident S LINE_IDENT data line type S LINE_TYPE tERA 030222141 rel 2 5 16 06 2014 22 data device serial address S DEVICE_SERIAL_ADDRESS data variable code Probe_3 gt lt div gt lt div gt lt div id div kitchen class div container style display none gt lt section id room container gt lt a href div livingroom class row link gt lt div class row container left row gt amp lsaquo lt div gt lt a gt lt div class img container gt lt img src S IMG kitchen jpg gt lt div gt lt a href div bathroom class row link gt lt div class row container right row gt amp rsaquo lt div gt lt a gt lt section gt lt div class main btn gt lt a href div index gt lt img src S IMG main icon png gt lt a gt lt div gt lt div class variable btn kitchen var placeholder data line ident S LINE_IDENT data line type S LINE_TYPE data device serial address S DEVICE_SERIAL_ADDRESS data variable code Probe_4 gt lt div gt lt div gt lt script src S CP_JS jquery min js gt lt script gt lt script src S CP_JS jquery ui min js gt
4. lt script gt lt script src S CP_JS custom pages js gt lt script gt lt script src S JS simulator js gt lt script gt lt body gt lt html gt Custom Page Variables Alarms tERA 030222141 rel 2 5 16 06 2014 25 Custom Page Variables Alarms tERA 030222141 rel 2 5 16 06 2014 24 Appendix B Function for assigning a variable value to a variable function test var url custom pages cp services LINE_IDENT LINE_TYPE DEVICE_SERIAL ADDRESS VARIABLE_CODE load S get url function data var value data value if value lt x do something j j In this example only the value of the variable returned by the web service Is used Remember that additional information can also be retrieved such as the type of line serial number type of variable see json format in the Plant graphics section Function to execute a check on the value of two variables var EN_Z03 var EN 204 var URL CN Z03 custom pages cp services S LINE_IDENT S LINE TYPEJ S DEVICE SERIAL ADDRESSYEN_Z03 load S get URL_EN_Z03 function data EN Z03 data value compareVariables var URL_EN _Z04 custom pages cp services S LINE_IDENTYS LINE_TYPEYS DEVICE_SERIAL_ADDRESSYEN_ Z04 load S get URL_EN_ Z04 function data EN Z04 data value compareVariables var compareVariables function if EN_ Z03 amp amp EN_ Z04 if EN_ Z03 1 amp amp EN Z04
5. an alarm Is activated To create a new notification rule click New The notification settings are divided into three sections Rule select or deselect the Enabled flag to activate or deactivate the rule To receive notification not only when an alarm is activated but also when it is no longer active select the corresponding Notify alarm termination flag In the priority section establish the priority or priorities of the alarms that are notified choosing between mg thah Msdum Low Very Lew The Selection field is used to specify the level for sending notifications all the installations in a community an individual nstllation c or an individual device Notifications this section defines the contacts who are notified of the alarms Time band this section determines the time period for sending notifications Once all the sections have been completed click Save to make the settings active 4 2 2 Reports The logged variables can be exported and downloaded from the portal and or sent via email This section features two tabs Report template defines a set of variables Click New and complete the fields Report scheduler click New and complete the fields to schedule a new report Select the required template the period the export time and corresponding time zone and the frequency of data in the report trace tTrace is a high level analysis service and an advanced reporting tool for comparison between different installation
6. needs to be selected using the checkbox IMPORTANT The zip file must respect the same directory structure shown in the HTML code for the correct definition of the paths and display of the layout As a reference in the example shown in Appendix A the zip has all the files in the root there are no directories example downloadable from KSA onthe right the Associations section specifying how to introduce the graphic interface The associations can be made at a template device and or installation level If being made by template the interface Is introduced on all devices that use the specified template otherwise it is introduced for the individual the devices and or installations specified Once both sections have been completed accessing the corresponding installations opens a new tab called Layout organised at an installation and or device level depending on the established associations tERA provides ready to use utilities which can be referenced as follows lt script src S CP_JS jquery min js gt lt script gt lt seript E EE JS JQu ry u1 mi1n Je gt lt sCripr gt To use standard query functions lt script src S CP_JS custom pagesys gt lt script gt Function for reading and writing variables Styles used by the previous files lt link href S CP_CSS jquery ui min css rel stylesheet gt lt link href CP_CSS custom pages css rel stylesheet gt The css and js files created by the user togethe
7. or more groups Note that the template will be visible and modifiable by users of the community it is associated with and will be visible to all the children however not accessible for modification The template is always visible to users of a higher level community see the Communities section The description of the template can be managed in different languages see the Multi language management section Clicking save displays a new section for creating the variables two modes are available 1 Click Import and choose the file to import the following file types can be imported Zip file zip containing the 2cf and 2ct files created using 1tool The offset parameter needs to be set correctly in order to ensure correct mapping of the integer variables For this reason check the value of the two variables shown in the table in the application 1tool Protocol number BMS_EXTENSION Offset MODBUS protocol Type re Coil 1 199 er MES iene mm 129 2 Register integer 129 255 Coil 1 207 rezent V KH Ze Register integer 209 415 Coil 1 2048 u Geer ie Register analog 1 5000 Register integer 5002 10001 Coil 1 2048 33 BMS1 BMS2 4 Register analog 1 127 Register integer 129 10128 33 BMS1 BMS2 1 5 Register analog 1 5000 Register integer 5002 15001 pCO WEB only Register analog 1 5000 Register integer 5001 10000 IMPORTANT If using Modbus over PLAN protocol the offset must be se
8. the server every 30 minutes tERA 030222141 rel 2 5 16 06 2014 17 The data on the box and on the server can be aligned whenever desired by clicking available only at a device level in the trends tab See the Event log section to check transfer status The page also needs to be refreshed F5 or to update the chart with the new data received The following feature is available at a device level Update Pco this section Is used to update the software on pCO controllers Create a zip file containing the necessary files and then select this by clicking petuesrace ie The files will be located in the corresponding sections Mask iup file Strategy blb bin blx files and Setting development file Click HA IMPORTANT it is strongly recommended to see the FAQ on Commissioning Tool Serial port configuration in 1tool to check the serial ports and BIOS versions required for correct operation IMPORTANT it is strongly recommended to upload a dev file corresponding to the specific application together with the application files Clicking on View all plants in the menu on the left accesses the alarm KPI for all the installations over the last month demo plant Reset alarms from 16 06 2014 to 16 07 2014 Energy Plant 4 2 Settings Setinos Only visible to tService administrator level users and comprises the following options 4 2 1 Alarm notifications Notifications can be received via email whenever
9. to check GSM signal strength The GSM status column shows the average communication quality low medium excellent Click on to view the trend in signal quality in more detail for further information To get the latest data click on 88 The chart is refreshed automatically once the samples are received by the server During communication between box and server sampling data is not available and is represented by a section in a different colour between two circles Click the date button to see information relating to a specific day or days The chart shows the values as a percentage of the optimum value and shows the data for the entire day 3 9 Minister service portfolio Wf This section of the administration area is used to manage subscriptions and verify related costs with the possibility to check consumption and modify the configuration for each subscription Clicking este for each subscription accesses Administration Service Package Plant demo plant Line RVRBXO0E00 D0000003 Line Type TBOX_ETHERNET Registration Date 2013 May 07 16 29 17 Management Configuration log Usage data Subscription management with the option to activate deactivate services and check thresholds Application Feature u i Status Feature Operation Active Application Operation Pr Live r amp c rging inate Y tWebServices EGE VANES Deactivate The table below shows the limits available for the functions included in the basic subscription tSe
10. used when configuring alarm notifications and sending reports tERA 030222141 rel 2 5 16 06 2014 12 Whenever a user is created the system automatically adds the corresponding contact details to the contact list If the E mail field is completed when creating a user the contact will contain the specified email address otherwise it can be added later To do this from the drop down menu on the bar at the top access Administration and then select Contact list and click P Addresses Different types of addresses can be added without limits the contact details relating to each user are deleted when the user is deleted Additional external contacts can be added to the portal using the new button 3 7 Plant graphics Be The view of each installation and or unit can be customised with html graphic elements by administrator level users For the use of this function users are assumed to have knowledge of html and JavaScript To customise the display from the drop down menu on the bar at the top access Administration and then select Plant graphics Click new complete the fields and click save A new row will then be displayed in the list Click the Configuration button to access a new page featuring two sections onthe left the Components section where the new button lists all the elements that make up the graphic interface Images html js css A single zip file containing all the required files can be used The default html file
11. 1 do something else do something else d tERA 030222141 rel 2 5 16 06 2014 25 NOTES tERA 030222141 rel 2 5 16 06 2014 26 tERA 030222141 rel 2 5 16 06 2014 21 CAREL CAREL INDUSTRIES SpA Via dell Industria 11 35020 Brugine Padova Italy Tel 39 049 9716611 Fax 39 049 9716600 http www carel com e mail carel carel com tERA 030222141 rel 2 5 16 06 2014
12. Data refreshed May 2 2014 at 3 00 27 PM LE Example 1 04 27 2014 00 00 to 05 03 2014 00 00 500 500 1 000 1 500 27 Apr 06 00 12 00 18 00 28 Apr 06 00 12 00 18 00 tBox Test Plant 01 DO00001 tBox Test Plant 01 DO00001 tBox Test Plant 01 D000001 tBox Test Plant 01 DO00001 tBox Test Plant 01 DO00001 tBox Test Plant 01 DO00001 tBox Test Plant 01 DO00001 tBox Test Plant 01 D000001 1 ETH R1 23 Modbus d 1 ETH R1 23 Modbus 1 ETH R1 23 Modbus 1 ETH R1 23 Modbus 1 ETH R1 23 Modbus 1 ETH R1 23 Modbus 1 ETH R1 23 Modbus 1 ETH R1 23 Modbus ANALOG_5 freq 5 value ANALOG_6 freq 30 value ANALOG_7 freq 180 value ANALOG_8 freq 900 value Analog input 1 value Analog input 2 value Analog input 3 value 1 Analog input 4 value Back Come PDF Come Excel Come Excel Come CSV IS S Impag 0 Come DOCX Come RTF Come ODT Come ODS Come XLSX Come XLSX 29 Apr impaginato When the report has been saved it will be displayed underneath the corresponding template in the My reports section Cares Headquarters il Folders Repository Carel s Headquarters descr A Organizations Name Ze PE Oe T S ports Dashboard BR My Reports del Resources Single chart Lema plant 1 Example 1 Model demo report 5 3 Report actions Sort By Hame Modified Date Description Type Cr
13. RNET tag in data type line If using the c pco enter the MAC address without decimal points in the data line ident field and C_PCO in data type line Appendix A shows an example of an html page for customisation Other examples can be downloaded from KSA http ksa carel com group tera1 custom pages The browser creates a copy of visited pages in its own memory called the cache In the event of problems displaying the custom page after having made changes it is recommended to clear the browser cache The following web services are made available for operations on the variables Read variable url custom pages cp services line identifier line type device serial address variable code load method GET result idDevice 2 idModelVariable 2 lineldent RVRBX00G00 A000123 lineType TBOX_WIRELESS or TBOX_ETHERNET or C_PCO deviceSerialAddress 1 variableCode var code canModify true false name var name value variable value uom CT type bool or decimal or mt or alarm Write variable url custom pages cp services devices idDevice variables idModelVariable save parameters value method POST result if ok success true else success false error Error message J Appendix B shows some simple functions that demonstrate the use of these URLs tERA 030222141 rel 2 5 16 06 2014 14 3 8 GSM signal monitor ill This section is used
14. ation can be assigned an image that is then displayed on the Plants page at end of the procedure click save to make the new installation visible in the list To associate a line with the installation click Ines mes and then click new In the serial number field choose the ID of the connection line that will be used Only the devices that have been registered and are not used will be shown in the list In addition a new connection line can be registered and associated with the installation using the Register button Complete the fields Protocol type type of serial protocol Modbus Modbus over Plan Carel c pco Bitrate Bitrate set on the serial line Data bits number of data bits set on the serial line Parity parity set on the serial line Stop bits number of stop bits set on the serial line Box PLan Id Id of the box in the PLAN network IMPORTANT The parameters set here must coincide with those set on the physical devices so as to enable communication Otherwise the OFFLINE alarm will be shown indicating a communication error The c pco is at the same time both a connection line and device and can automatically transfer all of its settings to the tERA server Consequently the protocol parameters should not be set selecting the create device flag creates the device automatically Once the line has been configured click save To add additional lines repeat the operation To allocate a controlle
15. ations can be made to already created reports Output options define the output file name language format Notifications configure email notifications Once all the sections have been configured click Save The scheduling settings will now be active 5 5 Customising a report The Resources Images directory contains predefined Images added to the reports These can be replaced by selecting them and then clicking the change button Each community can customise reports by adding new Images to the corresponding Resources directory 6 tDisplay Basic application with customisable interface to monitor installation data in real time and change the settings via a remote connection Once having accessed the desired installation two tabs are displayed three if custom pages have been created Variables this shows the list of all the controller variables for read and write Alarm 1 Enable operations Alarms this section shows all the active alarms in the installation The colour of each row represents the alarm priority By default the menu on the left is hidden To display it click gt If there is only one device in the installation this is accessed directly without needing to go through the installation level default setting Use the 10 5 200 buttons to change the number of variables shown on each page tERA 030222141 rel 2 5 16 06 2014 2 Example custom html page lt doctype html gt
16. eated Da Modified D Four Single charts in a unique report Report April 243 Apot 11 Compare dala from different plants on different perio Repant April 29 April 11 April 201 loday rion April 20 April 20 April 201 Apri 30 Select a report in My reports and click the right mouse button to access the possible actions available tERA 030222141 rel 2 5 16 06 2014 20 Carers Headquarters D Folders Repository Sort By Name Modified Date ei Carers Headquarters deser Dun Edil per Copy Cut ste Delete Be Organizations F oO Name Description Type Created Da Modified D om Reports Gasnboard Four single charts in unique report Report April 29 Apri 11 Single char Compare dala from diferen plants on diff rent perio Report April 39 April 11 nso BEMENT Example 1 Run Report Version April 30 April 20 Model demo report Schedule Report Version April 20 April 30 Options Eat Report Version April 29 Apel 29 Demo plant 1 Copy Report Version Today April 30 Cul Delete Properties 5 4 Scheduling a report Select the report in My reports and click the right mouse button Select Schedule A new page is opened showing all the report scheduling options Click Create schedule and complete the settings in all the sections Schedule enter the start and end time the time zone and the number of repeats of the report which may be basic every n minutes hours days weeks or custom selected months days e Parameters modific
17. esources 2 Configure the report on the new page click Options at the top right to enter the report settings Carel s Headquarters Single chart Data refreshed May 2 2014 at 2 58 09 PM E Sort By Name Modified Date Created Da Modified D April 29 April 11 April 29 April 11 Back E To make the configuration process faster if there is a similar existing report this can be loaded automatically by selecting it from the drop down menu at the top and then modifying the settings as necessary tERA 030222141 rel 2 5 16 06 2014 19 Input Controls Reports can be created for complete Installations templates all the devices with the same template will be displayed and individual devices These fields can be used individually or in combination to filter the desired variables to include in the report The variables can also be filtered by unit of measure All these fields allow multiple selection In the Time range field a number of default periods are available The interval can also be selected freely specifying the start and end date Using the Reference date field a second time period can be added to the chart for comparison The same Time range set will be displayed 3 Save and generate once all the fields have been entered it is recommended to save the report and then click OK to generate it Use the Export button to export the report in the different formats available Carel s Headquarters Single chart
18. filter buttons corresponding to the categories available for the current template Click the star to add the variable to the group of favourites The variables can be sorted by code and description by clicking the headings on the corresponding columns Alarms by default the data Is accessed in active mode listing all the active alarms on the selected controller in chronological order The colour shown on each row represents the alarm priority The Ack Y and Reset buttons are used to acknowledge and reset the alarm The alarms are only reset at a portal level an not physically To access the alarm log for the controller click e The alarms can be filtered for a certain period of time using the start time and period fields and then clicking 7 The alarms can be sorted by priority description and date by clicking the headings on the corresponding columns Trends by default the data is accessed in log mode showing the charts of logged data The logged data can be displayed over a daily weekly or monthly period starting from chosen date the current day is shown by default To select a specific period use the start time and period fields and click ra Ri IMPORTANT To be able to display the data relating to a variable on the chart the frequency field needs to be set to a value other than zero To configure the chart click Sonfoure graph A specific period on the chart can be displayed with greater detail zoom by selecting
19. it directly with the mouse Click to reset the zoom Clicking ED switches to live mode so as to perform sampling every 5 seconds and see the evolution of the data on the chart instantly clicking gt to start MM to stop or to delete the chart Click Sonfiure graph to select the variables to sample Any variable available in the template can be sampled Report used to export installation data in Excel format Select the required variables the period and date and the frequency of the data in the file Only logged variables will be included in the report The following table shows the possible combinations tService reports limits Report period Available frequencies Number of variables 10 wi Sg Daily 5 30 60 180 300 600 900 O with exception of the 5 second frequency where is it possible to export 2 variables To access specific devices in the installation simply click them in the menu on the left eso STE peo The same tabs are displayed only the information now relates to the individual device IMPORTANT the data are automatically sent at the following intervals GPRS box only if there are variables sampled with a frequency of 30 seconds or higher the data are sent automatically to the server every 12 hours H there are variables sampled every 5 seconds the related data are sent every 3 hours and all the other variables are transferred every 6 hours LAN box all the variables are automatically sent to
20. lt html lang en gt lt head gt lt meta charset utf 8 gt lt title gt Custom Page Simulator lt title gt lt link href S CP_CSS jquery ui min css rel stylesheet gt lt link href S CP_CSS custom pages css rel stylesheet gt lt link href S CSS simulator css rel stylesheet gt lt head gt lt body gt lt div id div index class div container gt lt section id main container gt lt div class preview container gt lt a href div livingroom gt lt img src s IMG livingroom jpg alt livingroom gt lt a gt lt div gt lt div class preview container gt lt a href div kitchen gt lt img src S IMG kitchen jpg alt kitchen gt lt a gt lt div gt lt div class preview container gt lt a href div bathroom gt lt img src S IMG bathroom jpg alt bathroom gt lt a gt lt div gt lt div class preview container gt lt a href div bedroom gt lt img src S IMG bedroom jpg alt bedroom gt lt a gt lt div gt lt section gt lt div gt lt div id div livingroom class div container style display none gt lt section id room container gt lt a href div bedroom class row link gt lt div class row container left row gt amp Isaquo lt div gt lt a gt lt div class img container gt lt img src S IMG livingroom jpg gt lt div gt lt a href div kitchen class row link gt lt div class row container right row gt amp rsaquo lt div gt lt a gt l
21. must always be added manually by other users who already have this profile To change the password access Profile from the drop down menu on the bar at the top of the portal the password must contain at least 8 characters 3 5 Communities amp Communities are used to limit access to and visibility of the elements available on the portal These represent a way of organising the data by creating groups of users and systems a user or Installation can belong to one or more communities however the users in a certain community can only view and access the defined installations and users On the tERA portal a default community is automatically created and cannot be edited or deleted This community is the parent of all the communities that are then created subsequently making up a tree structure in which each community can access all the elements relating to its child communities To create a community from the drop down menu on the bar at the top access Administration then Communities click new and complete the fields The parent community that the new group belongs to must always be specified If a community has child communities it cannot be deleted Consequently the delete button in the list of communities is disabled first the child communities need to be deleted then the button will be enabled Community default Community 4 3 6 Contact list 23 This section contains all the contacts on the portal that can be displayed and
22. n Identical copy of the element in question in the case of variables make sure the fields relating to the new variable are set correctly In both sections multiple elements can be deleted together using the checkbox available on every row and the buttons at the top right 3 2 2 Variable attributes Below is a short description of the different attributes that can be associated with each variable Code unique Identification code Category used to create groups of variables and simplify filtering and display The existing categories can be used or new ones created on the portal to do this in the variable editor click next to the category field and add the description Once the new category has been saved it will be available in the corresponding combo box category 1 General Description description of the variable Address in address occupied in the device s memory Address out specify only if different from the input Variable type Digital Alarm Integer Analog Frequency sampling frequency in seconds values supported are 5 30 180 900 Bit position first bit position of the variable for example bit O for a low byte variable bit 8 for a high byte variable Variable length effective length of the variable for example 16 bits if it occupies one complete word 1 bit typically for alarms Variable size size of the register holding the variables 8 16 expressed in bits
23. r Administrator maximum rights for all applications User limited functions for all applications Based on the application administrator users can access the following functions tService pco upgrade menu settings configuration of scheduled reports and alarm notifications tTrace Creation of new templates Report scheduling tDisplay User profile only tAdmin Access to the entire Administration section Community allocating users to a community limits their access rights and visibility to the installations templates and users allowed for that eroup user can belong to more than one community Access variable for reading defines the set of variables that will be visible to the user Access variable for writing defines the set of variables that can be written by the user Once the settings have been completed click Save to make them active By default a user can access all the applications available on the portal using the functions relating to their profile Click the Frr es button to manage the available combinations in the profile list disable access to certain applications grant administrator access for certain applications and user access to others etc tERA 030222141 rel 2 5 16 06 2014 11 Profiles tWebServices User r tAdmin Minister a tTrace User a tTrace Administrator tService Admin a tDisplay User a tService User a tAdmin administrator a close IMPORTANT the Minister profile
24. r to the installation click the re button under the Plants section or the lines section and then click new Complete the fields Name Description Line select the line that the device is physically connected to This field is not required it can be associated subsequently meaning it Is possible to first create the devices and then from the list of devices select several of these and use the Configure line button to create a multiple association Template select the of the list of controller variables The list shows the existing variables Address the device s serial address Click save to save the settings To view the list of the variables click oz The default settings entered in the template can be set for each individual device using the button for each variable Only the name description unit of measure frequency priority and alarm thresholds can be changed IMPORTANT It is recommended to start from a template that is as close to the final version as possible Once a template is being used it can no longer be modified which prevents the introduction of global modifications To add further controllers repeat the operation Each box supports a maximum of 10 devices To edit an installation a line or a controller click the corresponding edit button Plant configuration is now complete tERA 030222141 rel 2 5 16 06 2014 10 The MN icon shown in the row corresponding to the installation plant
25. r with the images must be referenced using the following tags to ensure correct operation lt link href S CSS style css rel stylesheet gt lt script sre s US Y script js gt lt script gt lt img sre S IMG imagejpg P gt The following tags are used for operations on the variables The custom pages js file is responsible for parsing var placeholder elements If the variable is read write when clicking its area a popup opens automatically for entering the value to write If wanting to introduce custom pages at a device or template level the tags shown in the following example can be used The system parses the information automatically lt div dass var placeholder data line ident S LINE_IDENT data lime type SILINE_TYPE data device serial address S DEVICE_SERIAL_ADDRESS data variable code Probe_1 gt lt div gt An installation plant can have two or more boxes and this prevents the tags from being parsed automatically If wanting to introduce custom pages at an Installation level the values of the different attributes need to be explicated for correct operation as shown in the following example tERA 030222141 rel 2 5 16 06 2014 13 lt div class var placeholder data line 1dent RVRBX00G00 D0000100 data line type TBOX_ WIRELESS data device serial address 1 data variable code Probe_1 gt lt div gt If using an Ethernet box enter code RVRBX00E00 in the data line ident field and the TBOX_ETHE
26. rvice 100 000 tService 100 000 Read and write variables with manual request by user tDisplay 5 000 tDisplay 5 000 updates month updates month Automatic variable logging 30 variables 300 variables Variable logging frequency Live recording duration ever y 5 seconds of installation variable trend 1 hour month 10 hours month pCO SW update If needing to extend these limits the corresponding feature needs to be activated Control subscription configuration history Control monthly consumption If required one or more additional services can be activated for one day only tERA 030222141 rel 2 5 16 06 2014 15 To extend these functions to other users under Administration Users click Profiles and add the corresponding option to the existing list 3 10 Multi language management Some of the descriptions on the display can be managed in different languages descriptions of the templates descriptions of the variables codes and descriptions of the installations and devices names of new categories Where available the button expands a list used to enter information in the desired languages The following languages are supported Description The language displayed depends on the language of the user who has accessed the portal If the descriptions only feature one language then that language is always displayed irrespective of the language of the logged in user If the language of the logged in user is not
27. s used to highlight the best configurations and optimise configuration tERA 030222141 rel 2 5 16 06 2014 18 5 1 Getting started Firstly select a community from the drop down menu at the top left If wanting to create a report for a sub community it is strongly recommended to access this sub community so as to have the same visibility as the end user and guarantee access to the data The directory structure is shown on the left with the following contents Root currently selected community Communities this directory contains all the sub communities of the selected community It should be noted that each organisation has the same directory structure Reports My reports existing templates and reports Resources logos for customising the reports Carel s Headquarters Folders SE Carel s Headquarters description al Organizations Sal Reports 3 My Reports Sal Resources Images 5 2 Creating a report 1 Select the template in my reports click an available template Dashboard four individual charts in one single report Single chart Comparison of data from different installations over different periods Carel s Headquarters Folders Repository Sal Carel s Headquarters descr SE Organizations hs Name Description Type gt Reports Dashboard Four single charts in a unique report Report E My Reports Single chart Compare data from different plants on different perio Report Hal R
28. supported the default language is used A toervice This application makes maintenance faster and more effective by analysing installation operation via a remote connection and improving service levels by reducing troubleshooting times 3 Access the installation from the home page by clicking echt Administrator Service View all plants Settings tera demo plant Vera Domo Variables Alarma Trends Report d3 tera demo 1 1 a d i Coda Dexeription Davies Value Des Actions Protocol Protocol d3 tera dermo 1 e E mDIGITAL_4 nul_en di tera dems 1 E ei Y Enable_Read_4 Probe Enable 4 d3Aera derno 1 E E MOlSITAL 3 rali end ditera demo 1 E G E mOGITAL 2 Zil eng d3 tera dema 4 am amp Y Enable_Read_1 Probe Enable 1 di 4tera demo 1 E G Probe_1 Analog input 1 diHera dermo 1 a E E ANALOG 7 Zil eng di tera demo 1 E ei mDIGITAL_1 mull_en didera demo 1 G Probe 4 Analog input 4 diAera demo 1 fr E CG 4 1 Functions The default view shows the data for the entire installation displayed in four tabs five if there are custom pages tERA 030222141 rel 2 5 16 06 2014 Variables this shows the list of all the installation variables Click to read the variable in real time and to write the value if the variable is configured accordingly To read multiple variables check on the checkboxes and then click at the top right The list of variables is arranged automatically using the
29. t section gt lt div class main btn gt lt a href div index gt lt img src S IMG main icon png gt lt a gt lt div gt lt div class variable btn livingroom var placeholder data line ident S LINE_IDENT data line type S LINE_TYPE data device serial address S DEVICE_SERIAL_ADDRESS data variable code Probe_1 gt lt div gt lt div gt lt div id div bathroom class div container style display none gt lt section id room container gt lt a href div kitchen class row link gt lt div class row container left row gt amp Isaquo lt div gt lt a gt lt div class img container gt lt img src S IMG bathroom jpg gt lt div gt lt a href div bedroom class row link gt lt div class row container right row gt amp rsaquo lt div gt lt a gt lt section gt lt div class main btn gt lt a href div index gt lt img src S IMG main icon png gt lt a gt lt div gt lt div class variable btn bathroom var placeholder data line ident S LINE_IDENT data line type S LINE_TYPE data device serial address S DEVICE SERIAL ADDRESS data variable code Probe_2 gt lt div gt lt div gt lt div id div bedroom class div container style display none gt lt section id room container gt lt a href div bathroom class row link gt lt div class row container left row gt amp lsaquo lt div gt lt a gt lt div class img container gt lt img src S IMG bedroom jpg
30. t to 5 Excel file xls Exported from the DeviceCreator software or completed manually template available together with the guide or on KSA see the section on variable attributes tERA 030222141 rel 2 5 16 06 2014 7 IMPORTANT If the Excel file is completed manually the addresses of the integer variables must be entered with the offset already applied If offset 1 or 4 gt integer variable address add defined in 2CF VAR_INDEX 128 If offset 2 gt integer variable address add defined in 2CF VAR_INDEX 208 If offset 3 or 5 gt integer variable address add defined in 2CF VAR INDEX 5001 If the Import procedure is not successful an error message will be shown with the settings to be checked in order to fix the problem 2 Use the editor on the portal Click new complete the fields relating to the variable and click save See the section on Variable attributes for further information IMPORTANT The addresses of the integer variables must be entered with the offset already applied The variables can be searched using the text filter and other advanced search filters The button can be used to display the user s favourite parameters the button is used to filter the variables based on different attributes Variables Gi Y filter Each template and each variable are associated with three buttons e Edit Ea to make changes e Delete EB to delete the corresponding item e Copy to create a
31. tERA CAREL Supervision and remote management services LEGGI E CONSERVA gt QUESTE ISTRUZIONI 4 READ AND SAVE Quick start gui de THESE INSTRUCTIONS Integrated Control Solutions amp Energy Savings tERA 030222141 rel 2 5 16 06 2014 CONTENTS We PACT SUING THESIS TEN eaaa ee 5 RO E E AE E A 5 ON RON E E E AE E A ES 7 3 1 Registering TE ele 7 RS PA 7 SICH VAIN OV a ai 10 A EB EINEENNEEIERERIESHEEER 11 35 Communities BP iii 12 3 6 Contact list 3 VA 12 3 7 Plant graphics iii 13 3 8 GSM signal monitor A 15 3 9 Minister service portfolio nn 15 A ll A e o en eee een ee een 16 SA 16 UN E 16 MAA nine 18 A TRE sscssscsnsnnsovesanscnosessnsonsessseonsvtansosssesassnnonbisassbecesannoopeesussbobeeansnescbnsnssoboinunnsobuvassooneestansoneotsnsotosesansnensesnnnsonbunesscedunsasenonstnanoosciin 18 5 1 Getting started cren re 19 5 2 Creating a 19 A PA 20 E ia i 21 A ccctecessncectce extent LEEREN RENNER KENNE EINEN NENENIENNEUINEE anda teeta teneutondatectesnte depesaeesetteaandslercintertetgeasesetes 21 A ZE 21 RO RR 00 AAA 22 A 25 tERA 030222141 rel 2 5 16 06 2014 3 tERA 030222141 rel 2 5 16 06 2014 Using a web browser go to the address provided by email and enter your system access credentials Once the private portal has been created requests to add new users must be sent to the system administrator and no longer to Carel To change your password go to the Users section The
32. tERA portal is optimised to work with Google Chrome E After having logged in to the tERA portal the home page is displayed This features two sections Plants section this is displayed by default and contains all the installations plants created even if they have not been completely configured a n search Carel terasupport Plants Applications y Sh y A 0 alarms Ta h 4 0 alarms h 4 0 alarms Da h 501 events tDisplay tService tirate 0 events tService Ce O 1632 events FA tService Trace Machine in Carel HQ J Energy Plant CRAC in lab CAREL Devices Devices Devices e Unit 1 e EM3 1 e FLCORMCRCP e EM3 2 For each installation the icons in the top right corner indicate the active applications while those at the top left notify users of any events and alarms To access the details of an installation in relation to a specific application simply click the icon corresponding to the application Applications section this contains the list of active applications and corresponding associated installations Simply click on an installation to access it The bar at the top of the page features the following sections Home carel terasupport e aan search On the left Home used to return to the Systems section Alarms contains the list of active alarms on all installations Events contains information on the most significant events on the portal Search search the installations bar using the te
33. that has just been created indicates that configuration is in progress the configuration needs to be loaded in order to make it active to do this from the lines section select ES Likewise whenever changes are made to the plant configuration the configuration needs to be loaded again to make it active The loading process is completed when the yellow icon is no longer shown The installation is thus active and available in the Home page If an error occurs see the Events log section for information on the causes Administration Plants Code Description operations demo plant Machine in Carel HQ ER lines devices FLCORMCRCP CRAC in lab CAREL ao ian ciao A Energy Plant Energy Plant ER lines devices 3 4 Users To manage system users from the drop down menu on the bar at the top select Administration then Users To create a new user click new and complete the required fields the username and password fields are used to access the portal The E mail field is not required rather it is used to complete the contact details that are automatically added to the contact list when each new account is created The contact details can also be completed subsequently Language the items on the portal and the descriptions of the elements created installations templates variables will be displayed in the user s language If avallable otherwise the default language will be used Profile establishes the functions available to the use
34. xt field and or the advanced search filters available by clicking On the right next to the user name is a drop down menu with the following sections Profile provides direct access to the user s profile settings tERA 030222141 rel 2 5 16 06 2014 5 Event log lists all the events on the portal Administration contains the section relating to the configuration if the user does not have tAdmin administrator rights this section Is not avallable Exit logout tERA 030222141 rel 2 5 16 06 2014 6 3 1 Registering a new subscription In order to use a new subscription the connection line needs to be registered box c pco under Administration Register box This can be done during system configuration see the section on Plant configuration Choose the type of line and complete the following fields serial number preceded by the part number RVRBX00G00 A0000XXX RVRBX00E00 A0000XXX and security code shown on the connection box label MAC address serial number and password parameters available on the screen on the c pco When clicking Save the line or access point will be available during system configuration 3 2 Templates 3 2 1 Creating a controller template Access Administration gt Templates click new and complete the required fields The Template field must be completed based on the type of connection device used The Communities field is used to associate the template to one