ioPAC 5500 Hardware User`s Manual
Contents
1. Install Moxa PComm Lite to the host Windows PC Run PComm Lite Terminal Emulator from Start gt Programs gt PComm Lite Ver 1 x gt Terminal Emulator 4 Click Profile gt Open g aPComm Terminal Emulator Profile Port Manager Help Open ca ejtal ame Br en 2B He 2 7 www ipc2u ru www moxa pro ioPAC 5500 Hardware Installation 5 Specify which COM port is connecting to the Moxa RTU and use the following configuration settings 115200 8 none 1 A xi Communication Parameter Terminal File Transfer Capturing Protocol Serial ha Baud rate Data bits Parity Stop bits Flow control f RISICTS F DTR DSR M XON XOFF RTS state ON OFF e ON C OFF 6 Click on the Terminal tab and configure the Terminal Type to VT100 Click OK to proceed AA A Communication Parameter Terminal File Transfer Capturing Terminal type FT100 sj B Local echo send Enter key as CR LF l Receive CE translation No Changed sj LF translation o Changed W Enable auto line wrap 7 The serial console will be displayed on the terminal screen BY COM1 115200 None 8 1 T100 lm raoti oxa ff Batterv The ioPAC RTU controller is equipped with one built in rechargeable VL2020 3V batterv for the SRAM and one 3V rechargeable batterv model number VL 1220 for the Real Time Clock RTC e Rechargeable battery VL2020 for SRAM gt Sustains at least 1
2. Please check Moxa s website for the most up to date certification status Warranty Warranty Period 5 years Details See www moxa com warranty www ipc2u ru www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction ioPAC 5500 LED Indicators There are 9 LEDs on the ioPAC controller EO OFO mi A ZOROROROROROROROFORORO OBOBOSOEO 020 m o e E T B 33388855838 uuu y w FEREREEE E8832 uu TT Yu Yu 7 soroBoro dodo do doORORORO RO OOOO OOO OOO OOOO CA E a EES iH ioPAC 5542 HSPA FR Svstem Power On Power On System Kernel Green System Ready System Blinking Green System is booting up Red System error firmware upgrade or reset procedure underway Blinking Red Factory reset triggered User Defined User Defined 1000000000 G fem Defined User Defined Green The CPU is executing PRDK OFF The CPU has stopped is not executing PRDK IEC Version i Red System I O services error LANI mil mail Green 100Mb Connection Amber 10Mb Blinking data transmitting Off disconnected P1 P2 Serial Green Transmitting data Tx Connection Amber Receiving data Rx Communication Off disconnected Link Cellular Green ISP IP retrieved Connection Off ISP disconnected Cellular Signal 1 amp 2 8 3 ON RSSI gt 24 1 8 2 ON 18 lt RSSI lt 24 1 ON Only 12 lt RSSI lt 18 Off No Signal RSSI lt 12 DIn DIOn Digital Input Green Chann
3. s pin assignment and I O wiring guide Pin Assignment www ipc2u ru ioPAC 5500 Hardware Introduction 00O OOOO J O eeeee000 0 Description Pin name Description COMO COM of DIO DI2 DIA 2 COM1 COM of DI1 DI3 DI5 and and DI6 DI7 012 piter imp channel2_ 6 or Dal Input creers 514 Dita imp Cremora 8 pr COM2 COM of DIOO DIO2 14 COM3 COM of DIO1 DIO3 DIOS DIO4 and DIO6 and DIO7 DIOO Digital Input Output 16 DIO1 Digital Input Output Channel O Channel 1 IO2 Digital Input Output 18 DIO3 Digital Input Output Channel 2 Channel 3 IO4 Digital Input Output 20 DIO5 Digital Input Output Channel 4 Channel 5 DIO6 Digital Input Output 22 DIO7 Digital Input Output Channel 6 Channel 7 AIO Analog Input Channel O Analog Input Channel 1 AIQ Analog Input Channel 0 Analog Input Channel 1 AI2 Analog Input Channel 2 Analog Input Channel 3 Al2 Analog Input Channel 2 Analog Input Channel 3 AI4 Analog Input Channel 4 Analog Input Channel 5 AI4 Analog Input Channel 4 Analog Input Channel 5 AI6 Analog Input Channel 6 Analog Input Channel 7 Al6 Analog Input Channel 6 Analog Input Channel 7 N 2 N N 31 3 11 www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction Digital Input Dry Contact Wiring Source Type NPN Din Din COM COM GND GND Sink Type PNP Din COM G
4. 2 6 A 4 channels 650 mA Over temperature Shutdown 175 C typical 150 C min Current Rating 200 mA per channel ioPAC 5500 Hardware Introduction www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction Software Characteristics Automation Languages C C IEC 61131 3 Protocols Modbus TCP Modbus RTU Master Power Requirements Power Input 24 VDC nominal 9 to 48 VDC Physical Characteristics Housing Aluminum Dimensions 90 05 x 135 x 105 4 mm 3 55 x 5 32 x 4 15 in Weight e oPAC 5542 HSPA Series 1100 g e oPAC 5542 Series 1000 g Mounting DIN Rail mounting standard wall mounting optional Connector Spring tvpe terminal block Environmental Limits Operating Temperature e oPAC 5542 Series 40 to 75 C 40 to 176 F e oPAC 5542 HSPA Series 30 to 75 C 22 to 176 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Altitude Up to 2000 m Note Please contact Moxa if you require products guaranteed to function properly at higher altitudes Standards and Certifications Safety UL 508 NCC Hazardous Location UL cUL Class 1 Division 2 EMI EN 55022 EN 61000 3 2 EN 61000 3 3 FCC Part 15 Subpart B Class A EMS EN 55024 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Shock IEC 60068 2 27 Freefall IEC 60068 2 32 Vibration IEC 60068 2 6 Rail Traffic EN 50121 4 Note
5. DIN Rail Installation Procedure Installing the oPAC 5500 on a DIN Rail The DIN rail attachment plate should already be fixed to the back panel of the ioPAC 5500 when you take it out of the box To install the ioPAC 5500 on a DIN Rail follow below steps NOTE A wall mount kit can be purchased separately STEP 1 Insert the top of the DIN rail into the slot just below the stiff metal spring STEP 2 The DIN rail attachment unit will snap into place as shown to the right Removing the ioPAC 5500 from a DIN Rail To remove the ioLogik unit from the DIN rail simply reverse Steps 1 and 2 above www ipc2u ru www moxa pro ioPAC 5500 Hardware Installation Configuring the Power Powering on the ioPAC Controller The ioPAC controller can receive power from a 9 to 48 VDC power Input power is applied to the positive V1 V2 and negative V1 V2 terminals on the connector e When the input voltage is below the minimum recommended voltage the ioPAC V2 will turn off V2 e The ioPAC has reverse protection and power input over voltage protection q allowing it to resist a maximum voltage of 60 V and the ioPAC s power input over current fuse protection specification is 5 A at 25 C V1 V1 After connecting the Moxa ioPAC controller to the power supply it will take 30 to 60 seconds for the operating system to boot up The green Ready LED will not turn on until the operating system is ready ATTENTION N This pro
6. Load Balancing l Balance alb Adaptive Load Balancing P 10 129 44 2 Single Serial Connectivity Connecting to a Serial Device The ioPAC RTU is equipped with two 3 in 1 serial ports that support RS 232 422 485 making it more convenient to connect field serial devices Pin RS 232 JAS 422 and 4 wire RS 485 _ 2 wire RS 485 1 bo tow E gt po how ON eno B www ipc2u ru www moxa pro ioPAC 5500 Hardware Installation Serial Console Debug Port The serial console gives users a convenient way of connecting to the RTU controllers This method is particularly useful when using the computer for the first time The serial console is also effective for connecting the Moxa RTU controllers when you do not know target network settings and IP addresses Step 1 To use the serial console remove the cover from the front top panel first Console Port for the ioPAC Series P2 onsole Step 2 Attach the 4 pin serial console cable to the console port The following diagram shows the 4 pin serial connector and pin connections Pin Assignment for the Serial Console Port Pin Definition Parity Nome Data bits BI We recommend using Moxa PComm Terminal Emulator to connect to the serial console The following steps describe how to connect the console 1 Download Moxa PComm Lite from the Moxa website www moxa com or copy it from the following folder on the Documentation and Software CD Software utility PComm
7. week without power supply gt Capacity 20 mAh gt Typical consumption O 25 C 4 yA gt 5 year warranty e Rechargeable battery VL 1220 for RTC Sustains power for at least 1 week without power supply gt Capacity 7 mAh gt Typical consumption O 25 C 2 yA gt 5 year warranty 2 8 www ipc2u ru www moxa pro ioPAC 5500 Hardware Installation Caution Do NOT attempt to replace the battery Contact your local dealer for replacement assistance www ipc2u ru www moxa pro www ipc2u ru IOPAC 5500 Hardware This chapter introduces the oPAC 5500 s hardware specifications The following topics are covered in this chapter O Appearance and Dimensions gt Appearance gt Dimensions O Hardware Block Diagrams gt oPAC 5500 RTU Controller Block Diagram O Product Hardware Specifications gt Product Selection Guide gt Product Specifications O ioPAC 5500 LED Indicators gt System LEDs Communication LEDs Cellular User Defined LEDs LED1 and LED2 IEC 61131 3 Compliant LEDs R S and ERR I O LEDs O The Toggle Switch gt In IEC 61131 3 Models gt In C C Models Vv Vv V WV O Toggle Switch Factory Reset Process O Pin assignment and I O wiring guide gt Pin Assignment Digital Input Digital Output Analog Input Voltage Y Vv V WV Analog Input Current 3 Introduction www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction Appearance and Dimensions Appearance The follo
8. www moxa pro ioPAC 5500 Hardware Installation Installing a SIM card ioPAC 5542 HSPA controller supports cellular network function user can unscrew and remove the SIM card cover to insert the SIM card Follow these steps to remove or install a SIM card 1 Remove the screw holding the card cover in place 2 a Insert the SIM card into the slot or b Remove the SIM card from the slot Connecting to the Network Ethernet Communication Connections to the LAN port are made through an RJ45 connector on the module The wiring and pin connections for these connectors are described in separate sections below e TCP IP Settings Dual Speed Functionality The ioPAC 5500 s Ethernet ports auto negotiate with the connected devices and then use the fastest data transmission rate supported by both devices The following table shows the TCP IP parameters supported by the LAN port Default values are set when a Factory Reset is performed on the controller Lan Port 1 Lan Port 2 Supported Values Supported Values IP Address Default 192 168 127 254 IP Address Default 192 168 126 254 Subnet Mask Default 255 255 255 0 Subnet Mask Default 255 255 255 0 Default 0 0 0 0 Default 0 0 0 0 IP Address is the IP address of the controller Subnet Mask determines the subnet on which the controller is located Gateway determines how your controller communicates with devices outside its subnet Enter the IP address of the gateway The
9. 31 3 40 to 75 C operating temperature ioPAC 5542 HSPA IEC T RTU controller with HSPA module 8Als 8 DIs 8DIOs IEC 61131 3 30 to 75 C operating temperature NOTE Conformal coating available on request Product Specifications Computer Main CPU 32 bit ARM9 192 MHz CPU I O CPU 32 bit ARM Cortex M4 80 MHz CPU OS Linux Clock Real time clock with battery backup Memory e SDRAM 64 MB e Flash 32 MB e SRAM 256 KB battery backup lasts for 1 week e microSD Slot Up to 32 GB SD 2 0 compatible Note For units operating in extreme temperatures industrial grade wide temperature microSD cards are required Cellular for the ioPAC 5542 HSPA Series Network e Quad band GSM GPRS EDGE 850 900 1800 1900 MHz e Five band UMTS HSPA 800 850 AWS 1900 2100 MHz Internet HSPA e Up to 5 76 Mbps upload speed e Up to 14 4 Mbps download speed UMTS Up to 384 kbps upload download speed EDGE Class 12 Up to 237 kbps upload download speed GPPRS Class 12 Up to 85 6 kbps upload download speed SMS Point to Point Text PDU mode SIM Control Voltage 3 1 8 V Ethernet Interface LAN 2 x 10 100 Mbps 2 MACs IPs RJ45 Protection 1 5 kV magnetic isolation Serial Communication Interface e 2 RS 232 422 485 ports software selectable DB9 male e 1 RS 232 debug port 4 pin connector Serial Line Protection 15 kV ESD for all signals www ipc2u ru www moxa pro ioPAC 5500 Hardware www ipc2u ru Serial Communicatio
10. IOPAC 5500 Hardware User s Manual First Edition December 2014 www moxa com product MOXA 2014 Moxa Inc All rights reserved www ipc2u ru www moxa pro IOPAC 5500 Hardware User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Trademarks 2014 Moxa Inc All rights reserved The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorporated into new editions of the publication Tec
11. IP address subnet mask and gateway are static contact your network administrator to obtain these addresses for the controller RJ45 Ethernet Connector The ideal maximum cable length of a 10 100BaseT connection is 100 m 350 feet but the actual limit could be longer or shorter depending on the amount of electrical noise in the environment To minimize the amount of noise Ethernet cables should not run parallel to power cables or other types of cables that generate electrical noise The following diagram and table shows the pin connections for the RJ45 Ethernet connector 2 5 www ipc2u ru www moxa pro ioPAC 5500 Hardware Installation RJ45 Connector Pin Assignment TX transmit Tx transmit 12345678 Media Direct Interface Signal Not used Not used Rx receive Not used Port Trunking The ioPAC 5500 RTU controller has a Port Trunking function active backup mode that can convert two LAN port IP addresses into one virtual IP address for easy SCADA integration and Ethernet redundancy In the following diagram both LAN ports on each ioPAC RTU controller are connected to a managed switch on an Ethernet network running SCADA software For more details regarding configuration setup refer to the ioPAC RTU Software User s Manual Port Trunking Mode Balance rr Round Robin Active Backup Fail Over Balance xor E HE Broadcast E IEEE 802 3ad Dynamic Link Aggregation Is Balance tib Adaptive Transmit
12. ND Digital Output Analog Input voltage Analog Input current Aln Aln DOn LOAD GND Aln Aln 3 12 www ipc2u ru www moxa pro
13. duct is intended to be supplied by a Listed Power Unit with output marked LPS and rated for 9 48 VDC minimum requirements For railway rolling stock applications these devices must be supplied by a galvanic isolated power supply with design based on the EN 50155 standard Grounding the ioPAC For most applications it is desirable to ground the system by connecting the system s power supply common wire to the chassis or panel ground The negative V side of the DC power input terminal as well as all I O point terminals labeled GND are connected to chassis ground P1 P2 Console V2 v2 V14 v1 NOTE 1 Use 18 AWG wire for the power ground 2 We highly recommend connecting the ground screw to the power terminal block s ground www ipc2u ru www moxa pro ioPAC 5500 Hardware Installation Installing a microSD Card The ioPAC is equipped with one slot for a microSD card The card reader slot is located inside the ioPAC device so you will need to unscrew and remove the card cover to install your microSD card When inserting a microSD card remember to keep the front edge of the card facing down Follow these steps to remove or install a microSD card 1 Remove the screw holding the card cover in place Cro gt 2 a Insert a microSD card into the microSD card slot or b Remove the microSD card from the microSD card slot 3 Fasten back the screw holding the card cover in place 2 4 www ipc2u ru
14. el ON or counter signal in pulse signal Output Indicator output scan rate 1 second Off Channel OFF or No Counter Pulse Signal Aln Analog Input Green Channel Enabled Indicator Red Burn out wire off when 4 20 mA current mode www ipc2u ru www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction System LEDs PWR Power LED The Power PWR LED indicates the status of the system power When the system is on this LED will turn green and when the system power is off this LED will be off RDY Ready LED The Ready RDY LED indicates the status of the system s kernel When the LED is green the system kernel is ready When the LED is green and blinking the system s kernel is booting up When the Ready RDY LED is red there is either a system error or the system is being reset to factory defaults When the Ready LED is red and blinking the device s factory default mode has been triggered Communication LEDs Pi and P2 The ioPAC controller comes with two serial connections P1 and P2 represent the status of each serial connection When the LED is green the ioPAC is transmitting data Tx When the the LED is amber the ioPAC is receiving data Rx When the LED is blinking randomly data is either being transmitted or received For example if P1 is blinking and is green the ioPAC is transmitting data When the LED is off the serial connection is disconnected LAN1 and LAN2 The ioPAC controller comes
15. hnical Support Contact Information Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 www ipc2u ru www moxa com su ort Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 www moxa pro Table of Contents Lo STRUROGUCTION i l at tt l 1 NS ON ita eed tien i eee a o ean tizdied l 2 Packaqe NE KI mererm Cem RNR eR TCR TET TT AAA E ES EEE EEE ELA EIC 1 2 2 A a E E E 2 1 Basic TAStAll atO ere E RARA AAA A AAA AAA AAA ii 2 2 DIN Ral Installation Procedura ii iii ui a i dd cidad 2 2 COMPGUPING the POW Cl a i iii i i i A A dn 2 3 Powering ON the loPAE CONTONE o arar N T 2 3 Grounding THEOPAC nret es e e iui os 2 3 Installing a MicroSD Card si seen eee ne tae l err rer errr ere reer 2 4 Merle ee a aj 2 5 COMMECEING tO the NetWork ii ii ii ic oie 2 5 Btnernet Communicator SiSES 2 5 Seta CONNECT RA EEN E SELENE EAN ES ARA S 2 6 Connmectina tora Serjal BDevjee is siti tiri AAA AAA Ata ae 2 6 Setial Console Debug PORE ei e d rd dee dana ta TA 2 7 Battista 2 8 3 JOPAC D5900 Hardware Introduction l a idad dada e aa 3 1 Appedrance ana DIMENSIONS ocio ais 3 2 Appeal CEE 3 2 DIMENSIONS ee A ili il ie 3 3 Hardware Block Diagram aaa caia 3 3 OPAC 5500 RIU Contr
16. itch is a simple run stop switch for IEC Stop programs Users can enable or disable it through RTUxpress The default Run setting is disabled Reset In C C Models On models that use the C language set the toggle switch is programmable Model 1 giving integrators and end users a switch that can trigger one of two M d 2 operation modes refer to the C C Sample Code Programming Guide oae for ioPAC RTU Controllers for details Reset Toggle Switch Factory Reset Process Use the following procedure to reset the ioPAC to the factory defaults Note that when you reset the ioPAC all of your tag definitions software programs and files will be deleted and the service and runtime engine will be restarted 1 When the system is booting up and the RDY LED is blinking GREEN hold the toggle switch in the reset position 2 Continue to hold toggle switch until the RDY LED turns a solid RED and then release the toggle switch It will take around 90 seconds to complete the factory reset process 3 When the RDY LED starts blinking GREEN indicating that the kernel is rebooting the factory mode is completed NOTE Do NOT power off operate or connect any devices when the RDY LED is a solid RED The factory reset function is only activated when the system is booting up 3 10 www ipc2u ru www moxa pro ioPAC 5500 Hardware Pin assignment and I O wiring guide The following is the ioPAC 5542 RTU controller
17. n Parameters Parity None Even Odd Data Bits 7 8 Stop Bits 1 2 Flow Control RTS CTS XON XOFF Baudrate 300 bps to 921 6 kbps Serial Signals RS 232 TxD RxD DTR DSR RTS CTS DCD GND RI RS 422 Tx Tx Rx Rx GND RS 485 4w Tx Tx Rx Rx GND RS 485 2w Data Data GND Inputs and Outputs Analog Inputs 8 channels Digital Inputs 8 channels Configurable DIOs 8 channels Isolation 3k VDC or 2k Vrms Analog Input Type Differential Input Resolution 16 bits 1 O Mode Voltage Current Input Range Oto 10 VDC 10 to 10 VDC O to 20 mA 4 to 20 mA wire off Historical Data Buffering 60KB per channel 120 second data buffer at 250 Hz Accuracy 10 1 FSR 25 C 0 3 FSR 40 and 75 C Sampling Rate e All channels 2000 samples sec e Per channel 250 samples sec Input Impedance 2M ohms min Built in Resistor for Current Input 120 ohms min Digital Input Sensor Type Wet Contact NPN or PNP Dry Contact I O Mode DI or Event Counter Dry Contact e On short to GND e Off open Wet Contact NPN DI to GND e On 0 to 3 VDC e Off 10 to 30 VDC PNP DI to GND e Off O to 3 VDC e On 10 to 30 VDC Common Type 4 points per COM Counter Frequency 1 kHz Digital Filtering Time Interval Software selectable by 0 5 ms Digital Output Type Sink I O Mode DO or Pulse Output Pulse Output Frequency 1 kHz Over voltage Protection 45 VDC Over current Protection
18. oller Block Die g ta isis en ete eer EN 3 3 PEOGUCE Hardware Specification 3 5 Product Selection GUia ei G i ios 3 5 Product Speciticatio i ie insiet at 3 5 OPAC S500 LED LINCE EE AE A EAN AAA AAA AAA AAA TO 3 8 System LEDS mcr cie 3 9 Communication LEDS airada dd de 3 9 A ee eC nnn or renee er ene ne rer ano oaanee 3 9 User Defined LEDS LED l ana LED 2 i ei e e rere Er AREI TORN is 3 9 TEC 6213 1 3 Compliant LEDS R S and ER dia 3 9 VO LEDS recensa A yoo 3 9 Moa AN 3 10 INMIECSO TESIS ModelSuccic ratico is bres bres bae Dr Bit tib fist Bit trb fin restos eti e cure dida 3 10 Be 6 MOG E S OCC e eur O a 3 10 Togale Switch Factory Reset PROCESS ais 3 10 Pin assighiment and 1 O Wir iG gude rimar arc eaianwaniaweewnanaiantenn 3 11 PIP ASSIGNING NE i i A 3 11 BA le her Ig O ceo A E B Terr ere TST rrr err errr Tre Bin er er er i 3 12 Di ital A E 3 12 Malo Na lohan i ONIO lt 2 arent a a ke ene ener 3 12 Analog ay ob heed 6G Ua gl a a aerate ie Sener nett a me ent cinta e a ee ete Ree er ener 3 12 www ipc2u ru www moxa pro 1 Introduction The following topics are covered in this chapter O Overview O Package Checklist www ipc2u ru www moxa pro ioPAC 5500 Hardware Introduction Overview The ioPAC 5500 standalone controllers use an ARM9 based industrial grade CPU for the main system with ARM Cortex M4 based CPUs for the I O channels The USB bus between the controller CPU and module CPUs transmits data at up
19. to 200 Mbps and the dual CPU architecture supports a 2 kHz analog input sampling rate and millisecond timestamps The ioPAC 5500 supports C C and IEC 61131 3 programming rail level surge and ESD protection a 40 to 75 C 30 to 75 C for HSPA models operating temperature range UL cUL Class 1 Division 2 certification two 10 100 Mbps Ethernet ports with two MACs Port Trunking ready and two 3 in 1 serial ports With Moxa s Active OPC Server and DA Center the ioPAC 5500 series provides a comprehensive solution for data acquisition and control applications in harsh environments Package Checklist ioPAC 5500 The ioPAC 5500 ships with the following items e ioPAC 5500 controller e Serial console cable C C models only e Documentation and software CD Optional Accessories can be purchased separately e WK 51 01 Wallmount kit www ipc2u ru www moxa pro www ipc2u ru This chapter includes instructions on how to install the ioPAC 5500 The following topics are covered in this chapter O a Basic Installation gt DIN Rail Installation Procedure Configuring the Power gt Powering on the ioPAC Controller gt Grounding the ioPAC Installing a microSD Card Installing a SIM card Connecting to the Network gt Ethernet Communication Serial Connectivity gt Connecting to a Serial Device gt Serial Console Debug Port Battery 2 Installation www moxa pro ioPAC 5500 Hardware Installation Basic Installation
20. wing figures depict ioPAC 5500 RTU controller Front View Antenna Connector OBO I O channels LED Indicator FEEEEREE SES SR Lo gees BORO RO BOR OB OF OFOROHOKOROBOSOS MicroSD Slot oggle Switch ioPAC 5542 HSPA Top View LAN2 la Ground Bolt Nut 3 in 1 Serial Port gt gt 7 Debug Port Power Terminal as Block v2 o V14 v1 3 2 www ipc2u ru www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction Dimensions Unit mm inch 61 0 8 F 9 0 35 Les SEL 120 4 72 ti e De LLI zo ys 7 2 0 28 105 4 4 15 10 0 39 90 05 3 55 wee ss adi Top View Front View Side View Rear View Hardware Block Diagrams OPAC 5500 RTU Controller Block Diagram CPU Board RAS 4 PHY Ras gt PHY 3 in 1 Serial Port 3 in 1 Serial Port Real time B2B to IO Board Clock EEPROM Console Port CPU Board 3 3 www ipc2u ru www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction I O Board IO Board 3G Board 3G Board www ipc2u ru www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction Product Hardware Specifications Product Selection Guide ioPAC 5542 C T RTU controller 8AIs 8 DIs 8DIOs C C 40 to 75 C operating temperature ioPAC 5542 HSPA C T RTU controller with HSPA module 8AIs 8 DIs 8DIOs C C 30 to 75 C anzjana a ioPAC 5542 IEC T RTU controller 8AIs 8 DIs 8DIOs IEC 611
21. with two Ethernet ports with the LAN1 and LAN2 LEDs used to represent the status of the two connections When the LED is green data is transmitting at 100 Mbps When the LED is amber data is transmitting at 10 Mbps When the LED is blinking data is being transmitted When the LED is off there is no Ethernet connection or the Ethernet connection has been disconnected Cellular The ioPAC 5542 HSPA RTU controller supports a cellular HSPA communications The Link LED can detect the communication status and the cellular signal can detect the signal strength of the cellular connection User Defined LEDs LED1 and LED2 The ioPAC controller allows the user to custom configure these two LEDs through the software interface Refer to the C C Sample Code Programming Guide for ioPAC RTU Controllers for details IEC 61131 3 Compliant LEDs R S and ERR The ioPAC controller supports IEC 61131 3 compliant Run Stop and Error ERR LEDs for ISaGRAF specific notifications These LEDs are not user configurable I O LEDs The ioPAC 5542 RTU controller has I O LED indicators that directly display the status of I Os on the front panel of the ioPAC 5542 RTU controller www ipc2u ru www moxa pro ioPAC 5500 Hardware ioPAC 5500 Hardware Introduction The Toggle Switch The toggle switch functions differently depending on the programming language set your ioPAC model is configured for In IEC 61131 3 Models For IEC 61131 3 models the toggle sw
Download Pdf Manuals
Related Search
Related Contents
Plaquette d`aide aux employeurs d`apprentis AT-UWC-APL ユーザーマニュアル Manual de usuario Manual Instruções REP Well Drilling Completion Data Submission system User Guide Belkin Screen Guard Transparent Overlay Télécharger Manuel Rob Papen SubBoomBass User Manual SELCOPY Manual HP Pavilion Slimline s5210uk + 2509m Copyright © All rights reserved.