Home

Enhanced Support Facility 2.4.1 User`s Guide

image

Contents

1. No MHz MB Impl Mask No MHz MB Impl Mask 00 CPU 0 300 8 0 3 4 0 OO CPU 1 300 8 0 3 4 0 OO CPU 2 300 8 0 3 4 0 07 CPU 0 300 8 0 3 4 0 O7 CPU 1 300 8 0 3 4 0 Used Memory Slot Number Size No B No MB No MB No MB OO SLOT A00 128 O0O SLOT A01 128 OO SLOT A02 128 00 SLOT A03 128 OO SLOT A10 128 00 SLOT A11 128 OO SLOT A12 128 OO0O SLOT A13 128 OO SLOT A20 128 OOQ SLOT A21 128 OO SLOT A22 128 OO SLOT A23 128 OO SLOT A30 128 OO SLOT A31 128 OO SLOT A32 128 00 SLOT A33 128 O7 SLOT A00 128 O7 SLOT A01 128 O7 SLOT A02 128 O7 SLOT A03 128 O7 SLOT A10 128 O7 SLOT A11 128 O7 SLOT A12 128 O7 SLOT A13 128 O7 SLOT A20 128 O7 SLOT A21 128 O7 SLOT A22 128 O7 SLOT A23 128 O7 SLOT A30 128 O7 SLOT A31 128 O7 SLOT A32 128 O7 SLOT A33 128 IO Cards Slot Name Model max freq 00 PCI 0B scsi glm Symbios 53C875 33Mhz OO PCI 0A SUNW hme pcil08e 1001 SUNW qsi cheerio 33Mhz O7 PCI 0B scsi glm Symbios 53C875 33Mhz 18 07 PCI 1B pci pcil011 24 33Mhz No failures found in System Initialization No Recent System Faults found Environmental Status MODE switch position is in LOCK mode System PROM revisions RST 3 11 1 1999 10 16 13 26 POST 1 1 8 1999 12 01 14 25 For PRIMEPOWER 650 850 900 1500 2500 HPC2500 opt FISVhwr sbin fjprtdiag v System Configuration Fujitsu sun4us Fujitsu PRIMEPOWER850 2 slot 8x SPARC64 IV 675MHz System clock frequency 112
2. Ussa Uvx1 Uvx2 Usdx 181 182 fen edddddddddddddddddddadadad sfc sfx ls_alR_spl_lp cl dspidcm showpsys ideminf trcidem trelzcs explo drestat scnet_error apnet_log clgetoralog ana pnavi pfed wvbs mplb srfs bbdts websysadmin mwupdate mwupdate_p 4 4 4 4 4 4 4 4 4 4 4 4 4 Part 4 Common Base Facility Part4 Common Base Facility describes the Common Base Facility 183 184 Chapter 11 License Manager This chapter describes FLEX m License manager that works on Solaris OE 11 1 Introduction to FLEXIm FLEXImmanages a software license on a network A license management program called the license managermanages the license The license manager runs on a machine known as the license server 11 2 How to Introduce FLEX lm Licensed Applications This section shows how to introduce FLEXI m licensed applications below 11 2 1 Selecting the License Server Machine The license server machineis the machine defined to the license manager as the machine on which the license server runs Before initiating the use of FLEXIm licensed applications you must select one or three machines three for redundancy to act as the license server The same machine as that used to run the application can be selected but it is recommended that a separate machine s in the network is used When two or more FLEXI m licensed applications are used the same license ser
3. Merits of redundant server operation Redundant server configurations enable continued management even when one of the license server machines shuts down Note that management cannot continue if two machines in the redundant server configuration are shut down Issues with redundant server operation When a machine has already been registered as the license server the license server cannot be changed to another later If this occurs due to unavoidable problems like a total machine failure the user must apply for a new password When 1 Add a New License Server is selected on 11 4 2Top Menu the following screen appears Adda New License Server Node Name Hostid Port Number 27000___ Exit Please enter Server Data Node Name of a License Server Cursor Key Move Cursor BS Back Space X Delete a char AT Insert a char L Screen Redraw AD Quit R Clear Field Return Key End Input a machine node name String returned by the uname n command hostid String returned by the hostid command and port number as the license server After the operation move the display cursor to Exit then press the return key In addition the default port number has already been set to 27000 Using a port number in the range 27000 27009 is recommended when specifying a port number Whenever the node name takeover of 1 1 standby is set with SynfinityClustersystem a different port number is set by each node The o
4. Volume Manager Information is collected by vxprint vxdg vxinfo vxdisk and vxstat Metadevice configuration information SPARCserver Manager Solstice DiskSuite Information is collected by metastat metaset and metadb Raid Manager usr lib osa rmparams usr lib osa rmlog log kernel drv sd conf kernel drv rdnexus conf kernel drv rdriver conf ls 1 dev osa dev dsk ls l dev osa dev rdsk Information is collected by drivutil rdacutil raidutil nvutil healthck and lad FUJITSU PCI SCSI Adapter Driver 1 0 2 0 kernel drv fjmisa conf kernel drv fjlvsa conf Hard Disk Driver Control Software kernel drv hddv_sd_backup kernel drv hddv_mphd conf_backup kernel drv hddv_mplb conf_backup FUJITSU Fibre Channel Driver kernel drv fjpfca conf usr sbin FJSVpfca fc_info a usr sbin FJSVpfca fc_info p usr sbin FJSVpfca fc_info c Multipath Disk Control load balance option var opt FJSVmplb multi path config log 177 MPLB 4 paths 8 paths 2 x var opt FJSVmplb multi path config log2 kernel drv mplb conf usr opt FJSViomp bin iompadm c mplb version usr opt FJSViomp bin iompadm c mplb p info MultiPath Disk Control kernel drv mphd conf var opt FJSVmphd mphdmon mphdmon log var opt FJSVmphd mphdmon mphdmon_bak log usr opt FJSViomp bin iompadm c mphd p info etc opt FJSVmphd bin mphdsnap sh 10 5 5 Network Related The network re
5. 171 Environment setting lt Log Operation status 10 5 1 1 Hardware Configuration System configuration prtconf v prtconf vp prtconf V format hrdconf 1 prtcfg 10 5 1 2 Software Configuration System name uname a showrev a pkg installation status pkginfo l pkginfo i pkginfo p var sadm install contents var sadm pkg pkginfo Modification application status showrev p ls l var sadm patch Kernel information ls l platform arch k kernel Load device driver list modinfo System installation var sadm softinfo INST_RELEASE ls ld var sadm System definition instruction set architectures isainfo kv 10 5 1 3 Environment Setting System tuning parameter etc system sysdef sysdef d etc name_to_major etc path_to_inst etc release etc conf Inittab etc inittab System procedure ete rc Driver definition kernel drv conf platform arch k kernel drv conf Device definition etc device tab etc dgroup tab etc security etc devlink tab EEPROM eeprom Device special file ls 1 dev rdsk ls IL dev dsk find dev type d print xargs ls IL ls IR dev mount default value letc vfstab 172 df k df a Free disk capacity df e df g Partition configuration prtvtoc dev rdsk c s2 Environment setting parameter letc
6. Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x00 An abnormal power supply unit cannot be specified 0x01 04 Power supply and voltage are abnormal 0x05 Power supply unit which depends on device is abnormal OxYY is detailed information which supplements the event code OxZZ OxNN is a power supply unit type or number and it depends on the corresponding RCI device 0xMM shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the power supply unit of the BBB and please contact our customer engineer WARNING FJSVscf thermal alarm on RCI addr 0xXXXXXXXX AAA sub status OxX6 sense info OxXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0xNN Meaning Detected an abnormal temperature sub status 0x06 or 0x86 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected 64 When sub status is 0x86 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the sensor type represents the sensor number AMBIENT is an environmental temperature
7. If there is no console messages of the se driver mentioned above some error might be occurred between the RS 232C cable and the System Management Console If you cannot recover by using the following steps call a Fujitsu customer engineer 1 Check the cable connection from the RS 232C cable to the System Management Console 2 Execute the iompadm c fjmse info command to display the status 3 Change the another communication path which is in the standby status to the active status by using the iompadm c fjmse active command 9 3 DR Connection Script FJSVse The console path which can be activated is about to be lost This process is interrupted Meaning If the disconnection processing is continued the console cannot be used So this process is aborted Action Make sure a communication path in the state standby exits If there is a communication path in the state fail or disconnected recover the fail or disconnected path by connecting or if necessary exchanging the system board Call a Fujitsu customer engineer when this trouble is not solved 163 164 Part 3 Maintenance Facility Part3 Maintenance Facility describes the System Data Output Tool 165 166 Chapter 10 System Data Output Tool This chapter describes the System Data Output Tool 10 1 Feature Overview This tool collects command execution result data and files about hardware and software configurations environment settings logs
8. false is displayed AutoPath Indicates whether the communication path is switched automatically In the case of console true is displayed because the fjmse driver switches a communication path automatically lt Block Indicates whether user direct access to the communication path is limited In the case of console since only the fjmse driver controls communication paths to prevent users access to them directly true is displayed NeedSync Indicates whether the fjmse driver needs to synchronize data of communication path In the case of console false is displayed 8 1 1 2 status subcommand DESCRIPTION The subcommand status displays the status of all the communication paths that belong to the specified instance This subcommand also displays the status of the specified communication path SYNOPSIS usr opt FJSViomp bin iompadm p c fjmse status instance name communication path namel EXAMPLE When p option is not specified usr opt FISViomp bin iompadm c fjmse status dev FJSVhwr fiomp mse0 dev fjse 0 online active block TAT dev fjse 1 online standby block Specify a communication path name usr opt FISViomp bin iompadm c fjmse status dev FJSVhwr fiomp mse0 dev fjse 0 dev fjse 0 online active block we 8 1 1 3 ident subcommand DESCRIPTION The subcommand ident displays the class to which the specified communication path belongs SYNOPSIS usr opt FJSViomp bin iompadm ident communicatio
9. var sadm smeptf var sadm system logs root mail var mail root 174 Network netstat a netstat an netstat s netstat m netstat p netstat r netstat i netstat k netstat pn netstat rn arp a nfsstat nfsstat m NIS nisshowcache v Connection server log var adm log uucp var uucp Modem var adm aculog Process account var adm pacct var adm acct FLEX m var opt FSUNlicense log tmp license_log Option var opt Web Based Admin View trace var opt FJSVwvbs logs WWW Server for Admin View trace var opt FJSVwvenf logs Storplex LMF Server var opt FJS Vlmfs Machine administration monitor log var opt FJSVmadm log Machine administration hardware error monitor database var opt FJSVmadm etc madmdb Watchdog log var opt FJSVhwr wdlog SCF error log var opt FJSVhwr scferrlog Power log var opt FJSVhwr scfpwrlog Hardware holt log var opt FJSVhwr hltlog TCPTRACE var opt FJSVssf tcptrace Netcompo Communication Service 1 0 var opt FSU Nnet cmsv log errlog pathfile Crash Dump Assistant var opt FJSVdmp log Machine administration var opt FJSVcsl log System Management Console var opt FJSVscsl log Crash dump analysis file lt crash dump dir gt ana Enhanced Support Facility Information Management opt FJSVbse etc
10. 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 UPS became an electrical discharge end voltage OxYY is UPS number and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of UPS connected with the RCI device displayed with addr UPS battery is charged or please contact our customer engineer WARNING FJSVscf UPS failure on RCI addr 0xXXXXXXXX was detected sub status 0x X5 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected a UPS failure sub status 0x05 or 0x85 of RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXKXX 0xZZ shows the event code 0x02 UPS hardware failure 0x03 UPS battery failure 0x04 UPS circuit protect
11. Action Allocate memory since there might not be enough kernel resources 82 WARNING FJSVscf scf_dma_alloc ddi_dma_addr_bind_handle ccountp error Meaning Could not allocate continuity area to the abnormal termination of ddi_dma_addr_bind_handle 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf detach ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING pci FISV scfc scfc IOCHRDY interrupt occurred Meaning IOCHRDY timeout Ebus2 timeout interrupt occurred Action Check the state of the system board and SCF device WARNING pci FISV scfc scfc DMA host bus error Meaning Host bus error interrupt occurred to the Ebus2 DMA Action Check the state of the system board and SCF device WARNING pci FJSV scfc scfc SCF command 0xXXXX receive data sum check error Meaning Detected Sum check error to the receive data of SCF command 0xXXXX Action Check the state of the system board and SCF device WARNING pci FJSV scfc scfc SCF command 0OxXXXX error Status register OxYYYY Meaning SCF command 0xXXXX terminated abnormally OxYYYY represents the SCF 2 Status register Status register has the following meanin
12. Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x02 UPS hardware failure 0x03 UPS battery failure 0x04 UPS circuit protector failure OxYY is UPS number and detail information and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of UPS connected with the RCI device displayed with addr Check to make sure that nothing is wrong with the UPS or please contact our customer engineer WARNING FJSVscf cannot report PANIC Meaning Could not notify the system panic on the other HOST when it occurred WARNING FJSVscf scf_map_regs ddi_dev_regsize failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_regsize 9F gets the register size Action Check the state of the SCF device WARNING FJSVscf scf_map_regs ddi_regs_map_setup failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf kstat_create failed Meaning kstat_create 9F failed Action Allocate memory since there might not be enough kernel resources 79 NOTICE FJSVscf switch status is unknown Meaning There is a problem with the panel switch setting Action Check the
13. Make sure that the SCF driver package is installed properly rciopecall not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges rciopecall ioctlQ failed Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly rciopecall invalid rci address Meaning Invalid RCI address Action Check the RCI address 138 rciopecall invalid callNo Meaning Invalid callNo Action Check the callNo rciopecall malloc failed Meaning malloc 3C failed Action Allocate memory or a swap area rciopecall RCI xxx does not exist Meaning The RCI device that has specified RCI address XXX does not exist Action Check the specified RCI device 6 22 nodeled 1M comamand Usage nodeled led check status nodeled led check mode on blink off Meaning Displayed when there is an error in the way a command option was used nodeled not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges nodeled cannot open dev FJSVhwr rasctl System call error message Meaning Failed to open the SCF driver Action Make sure that the SCF driver package is installed properly nodeled ioctl0 failed System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver
14. PRIMEPOWER PRIMEPOWER 650 850 1 600R 250 450 800 1000 900 1500 PRIMEPOWER 2000 2500 HPC2500 200 400 600 POWER Switch o o ty o 1 settings System time O sl UPS Operation o 1 x1 1 time O Setting is possible Setting is unnecessary 1 Refer to the explanation of each feature though the setting is unnecessary Software settings can be made using scftool 1M or scfconf 1M Refer to Table 1 5 Each model offer list of scftool 1M and scfconf 1M for each model by whom scftool 1M and scfconf 1M are offered Table 1 5 Each model offer list of scftool 1M and scfconf 1M Models GP7000F model 200 200R 400 cs PRIMEPOWER Command PRIMEPOWER 400A 400R 600 PRIMEPOWER 650 850 PRIMEPOWER 1 600R 250 450 00000 900 1500 PRIMEPOWER S006 2500 HPC2500 2 00 400 600 scftool 1M X 0 X 0 X scfconf 1M O O X X X O offer X Unoffer scftool 1M overview scftool 1M provides a user interface using Motif scftool 1M can be used in an OpenWindows or CDE environment Figurel 1 scftool screen for GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWE R 200 400 600 scfconf 1M overview scfconf 1M is the software setting command with the CUI interface For information on how to use scfconf 1M refer to 3 5 scfeonf 1M 1 3 2 1 POWER Switch Settings This software can be used to automatically shut down the system when the POWER switch
15. SYNOPSYS usr opt FJSViomp bin iompadm c class name version EXAMPLE Example For PRIMEPOWER 850 usr opt FISViomp bin iompadm c FJUSVscf3 version iompadm Version 1 0 0 1999 12 04 FJIOMP API Level 2 0 FUSVscf3 2 0 FJSVscf3 API level 1 0 3 13 1 8 help subcommand DESCRIPTION help subcommand displays the usage of the iompadm command SYNOPSYS usr opt FJSViomp bin iompadm c class name help EXAMPLE Example For PRIMEPOWER 850 usr opt FISViomp bin iompadm c FJSVscf3 help subcommand help Shows this help message ident Returns the class name for IOMP device info Returns information about an instance probe Returns class and instance name for IOMP device recover Recovers the path after an error start Restarts the use of a path status Returns the path status version Shows versions 37 3 14 prtdiag 1M Refer to fjprtdiag 1M usage iom iom iom iom iom iom iom iom padm padm padm padm padm padm padm padm FJSVscf3 FJSVscf3 FJSVscf3 FJSVscf3 FJSVscf3 FJSVscf3 FJSVscf3 FJSVscf3 help ident device nam info instance name probe device name recover instance name device name start instance name device name status instance name device name version prtdiag 1M command offered in before ESF2 1 is offered by fjprtdiag 1M command in ESF2 2 or later 38 Chapter 4 Driver Messages This chapter gives the meaning of mess
16. WARNING FJSVsfled ddi_copyin failed Meaning Failed ioctl due to the abnormal termination of ddi_copyin 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled ddi_copyout failed Meaning Failed ioctl due to the abnormal termination of ddi_copyout 9F Action Allocate memory since there might not be enough kernel resources 95 WARNING FJSVsfled sfled_start SCSI transport error occured Meaning SCSI transport error occurred on SCSI Host bus adapter Action If this message is displayed repeatedly check the state of SCSI Host bus adapter WARNING FJSVsfled scsi_init_pkt failed Meaning Failed to allocate kernel resources for SCSI transport Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled sfled_restart SCSI transport error occured Meaning SCSI transport error occurred on SCSI Host bus adapter Action If this message is displayed repeatedly check the state of SCSI Host bus adapter WARNING FJSVsfled sfled_callback SCSI transport error occured Meaning Error occurred during SCSI command transportation Action If this message is displayed repeatedly check the state of SCSIFault LED device or SCSI Host bus adapter WARNING device node name FJSVsfled gt status 0x sense_key 0x ASC 0x ASCQ 0x Meaning SCSI command error occurred on Fault LED device described as device node name Action If this messag
17. ile bea als Be ge hig b errr EE eeeerenten errr rr enter E EED E EEE AEE E errr eererrse 3 bt FEA 0 6 ee er pe eee ee ee eee eee 3 12 System Operation osoei lee in elo ee eee eee oneness 3 21 BOOt ses seed EEEE S EE EAE E E EE EE EAEE EEE EEEE E 3 1 2 2 SHUtdOwn sree ctv ch es EE Sd T he eee eee EN eis i EEE TEER EES 3 1223 Using Panel CGOmtrols ses oo chexs oes os eee a sos Go eh Ei RE 4 1 2 3 L MODES WIth erren E EE E EEE E cvs NTE E e E E 4 EAA E D D Wamp AAE EEE A O E AE E EEE 5 12 383 LCD Panek sgornain a in BS et ee oh a e Bk 6 1 2 3 4 Other Switches sorso iieri e ves ee den catgeleca A EA E Gan ceeest naib i EERE 6 1 2 4 Shutting Down and Booting the System cccceccsscccesssececeeeaeeecseececeeaececseseeeeceneeeessaececsesaeeseneeenes 6 T3 Server SOUP osia ee ential niet lee nee nite edn dia aden 6 Teo Changing PAW n BEE EE E AAEE E A E EEE E EEE Dec basa AEREA eas 6 1 3 2 Feature Settings en nonar A E E A E a Reat 7 1 3 2 1 POWER Switch Settings gsp enie r a E aeie on aaa rran Siiri a Ea 8 IER ASNA A23 a0 DA K T iTe ASEE AEE EE E EE E E EE NE tia E E EEE EE AE ETE tease 8 1 8 2 8 UPS Operation TIME sasinan e enr eaa Eee aa a EEEE EEE REE a e AEA E RE aa 9 L3 2 ACNOCES sears a e a a A a fed atte a Feat S 9 124 Troubleshooting ss aeaa R AEE TEE EAEE E 9 1 5 Processing when UPS is connected and power failure occurred ccccceseeeetceeeeeeeeeeteees 10 1 6 kernel parameter of SCF Criver cccccc
18. scf_attach ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_create_minor_node failed Meaning Failed to incorporate the SCF driver into the system because the creation of the device minor node failed Action Make sure there is enough room in the device file system WARNING FJSVscf scf_attach kmem_zalloc failed Meaning kmem_zalloc 9F failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_add_intr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr 9F registers interrupt functions Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_get_soft_iblock_cookie failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_iblock_cookie 9F allocates resources for soft interrupt processing Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_add_softintr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_softintr 9F registers soft inte
19. specified with status parameter ON LED lamp is lit BLINK LED lamp is blinked OFF Lighting or blinking the LED lamp is released This parameter is returned to the previous state to which the LED lamp is lit or blinked by this command status The state of the LED lamp is displayed This parameter cannot be specified with mode parameter ON State of lighting BLINK State of blinking OFF State of turning off EXAMPLES opt FISVhwr sbin nodeled led check mode blink opt FISVhwr sbin nodeled led check status LED CHECK Amber ON EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error 3 13 iompadm 1M NAME iompadm Multipath control command SYNOPSYS usr opt FJSViomp bin iompadm p c classname subcommand parameter 31 AVAILABILITY FJSVpscu FJSVscu2 FJSVscu3 FJSViomp DESCRIPTION iompadm displays the status of the communication paths composed of the interfaces This command also restores the communication path where a failure occurs You can display the status of communication paths or restore them using the combination of the specified subcommand and parameter A communication path is a path that the SCF driver uses for communications with a SCF driver one communication path for each system board The following models can use this command lt GP7000F model 1000 2000 PRIMEPOWER 250 450 650 800
20. thermal alarm X SENSOR Meaning Detected an abnormal temperature X is a number representing the cause 1 Ambient temperature low temperature warning Ambient temperature low temperature alarm Ambient temperature high temperature warning Ambient temperature high temperature alarm 2 3 4 5 Unit Processor low temperature warning or sensor failure 6 Unit Processor low temperature alarm or sensor failure 7 Unit Processor high temperature warning 8 unit processor high temperature alarm represents the sensor ID Action Check the environment where the unit is set up Also make sure there is nothing wrong with the inside of the unit 47 WARNING FJSVscf AC power down was detected UPS is activated Meaning Power is now being supplied by the UPS due to a power down FJSVscf AC power recovered Meaning Power was restored WARNING FJSVscf UPS low battery UPS Meaning Power from the UPS has run out UPS represents the UPS number Action Charge the UPS battery WARNING FJSVscf UPS failure UPS Meaning Detected a UPS failure either a UPS hardware failure UPS failure or UPS circuit protector failure UPS represents the UPS number Action Check to make sure that nothing is wrong with the UPS WARNING FJSVscf SCF battery alarm BATTERY Meaning Problem detected in the battery backing up SCF SRAM represents the battery number Action Check the battery
21. var file system scfhltlog bounds write failed Meaning Failed to write var opt FJSVhwr wdlog bounds file Action Check the state of the var file system usage scfhltlog h n f device d directory Meaning Displayed when there is an error in the way a command option was used scfhltlog Halt log was not saved correctly on SCF Meaning The hardware halt log exists on the SCF device but it was not saved correctly Action Check the state of the SCF device 6 20 scfnotice 1M command Usage scfnotice pfail Meaning Displayed when there is an error in the way a command option was used scfnotice not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges 137 scfnotice failed to open dev FJSVhwr rasctl scfnotice failed to open dev FJSVhwr rasctl2 Meaning Failed to open the SCF driver Action Make sure that the SCF driver package is installed properly scfnotice ioctl0 failed Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly 6 21 rciopecall 1M command Usage rciopecall address disp on callNo off callNo Meaning Displayed when there is an error in the way a command option was used rciopecall failed to open dev FJSVhwr rcictl rciopecall failed to open dev FJSVhwr rcictl2 Meaning Failed to open the SCF driver Action
22. 000101ff off Oc rciopecall 000101ff disp address 000101ff callNo 0c status 00 NOTES Note that only the super user can execute this command This status code returns the following values 00 Meaning Ended normally Not support on Meaning the specified node 20 i Check the RCI Action address Command Meaning Timeout ao Check the RCI Action address and retry to the command EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error 3 12 nodeled 1M NAME nodeled LED lamp control status display command of this system SYNOPSYS LED lamp control opt FJSVhwr sbin nodeled led check mode on blink off 30 LED lamp status display opt FJSVhwr sbin nodeled led check status AVAILABILITY FJSVpscu DESCRIPTION This is a command to display the control and the state of the LED lamp of Main Cabinet In this command the CHECK lamp of the Main Cabinet can be controlled To specify the target processor from remoteness at maintenance the CHECK lamp is lit or can be blinked by this command Moreover status display of the CHECK lamp can be done The following models can use this command PRIMEPOWER 250 450 OPTIONS The following options are available led check Specify the LED lamp This parameter can be omitted check CHECK lamp mode Specify ON ighting BLINK blinking and OFF release of the LED lamp This parameter cannot be
23. Class not Found Meaning Class name specified by XXX does not exist Action Specify a correct class name 6 24 DR Connection Script message Can t disconnect for last SCFC Meaning Disconnect cannot be executed because of the last SCFC iompadm command abnomal end action XX path YY Meaning iompadm command error XX represents the subcommand of the iompadm command YY represents the path name Action Check the status of the displayed path If there is still a problem call a Fujitsu customer engineer 142 Part 2 Serial Port Driver Features PRIMEPO WER800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models 1000 2000 Part2 Serial Port Driver Features PRIMEPOWER 800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models 1000 2000 describes console connection via the onboard serial port of PRIMEPOWER 800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models 1000 2000 143 144 Chapter 7 Connecting the Console This chapter describes console connection via onboard serial port 7 1 Feature Overview This section provides an overview of the features and structures offered by the serial port 7 1 1 Hardware The console terminal is displayed in the RC2000 Remote Console 2000 window of the System Management Console via the CCU Console Communication Unit which converts RS 232C to Ethernet Using RC2000 it is possible to display one or more console terminals for each partition in one System Management Console These
24. EEEE EEE AE E N T S 147 TAA Messa fesieri rei aeie cas EEEE EER Solos ENEE EEP N Sod unde do Ee t E Eiaa 147 Chapter 8 Command Reference sivicicccisit sensi sesaeeninet i sttisssaceeise beanisteavesanee dees tiaiiias 149 SAiompadm IM elses seed tela Ae A seein adie eae ae teed 149 8 1 1 PompadmM SUDCOMMANAL cececececccccccececeeeeeeeeeeeeeeeeeseeeeeeeseeeeeeeseseeeeeeeeeeeeeeeeeseeeeeeeeeeeseeeseeeseseeese sense ee 150 SET Vl NfOtS UD COMMAS siccvecs E E EEE E nk EEEE E E E E da cob otek owed bos teeth ET 150 S171 2status SUbCOMMANG inenen eE vdascccsesasteodvacccgeviesscgelsebacgeeuessctesslecsaescetacedcodeveaieees 152 SAL ABdent SUbCOMM AND 244523 herseeevesssads Bonavevvecasecd Bice avesyadasdes Rvaadesdncks 00s Gieavectncshes Mbaadesanacadcdeetadeseee teas 152 Sill 4 probe subcomiim anid e aa E ded ahha te ecw ec See ted Sa edad eee tec tees cael eels 152 8 1 1 5 recover SUDCOMMANA cccececsesesesesessesseaeseseaeseaeaeseseseaeaeaeaeaeaeaeaeseseaeaeaeaeseseaeaeaeneneaeaaaeeeeeeeeess 1538 STA Gistart SubCOM MAN mere er e ar a Sean adesnadasdes Mv aecsvecitOsa Seog Marndesbas aa ia aaraa 153 Sibel e7 ACHVE SUDCOMIMAN Gs eae aa EA dae Reba tee Secu ted ea be dad ae be teste dee coated he 153 8 1 1 8 version subcommand s sssssssssssssesesesesesesesesererrresrrerrrerrrrresrorrrresrrrresrsrorstsrserrrtoroereorreorrrererereses 153 8 19 Help s b omman d eme rat ae ane a e i a Medes a a a 154 Chapter SIMGSSAQeS oor ceezcns etre sence Ae
25. Ean e E E eE EE E y 6 setup licenser en 186 190 sh td wM onneen E E 3 Shutdown OND erana a a me SING OSCLV EP vss scssdeeeessetesecesecesveedssesusesseeseosseteescel L87 software settings e esssssesererssssesreecsesseseeereese wet Sram backup iisisciiscese sevsevde saves sesevesveestvevviesesseveesel 128 start subcommand 2 0 00 eeeecececeeeestteeeeeees 37 153 Star UP reece eres ae E 186 191 status subcomman ccceccececeeeeserteeeeees 35 152 E EA cele cect ete tO actors ETE 9 SynfinityCluster c cccccccsssssccceceeeensenees 185 187 syslogd iM a a taser sean 16 system call error message 06068 39 103 117 System Data Output Tool cece eeeeeeeeee L67 system diagnostic information cccccccccceeeeees 15 system OPCLAtION ccccceeesseeseseseseseeeeeeeeeeeeenenens 3 system standard clock cccccecececeeseeeeeeeesenenens 9 T U unit connected via RCI cccccccceeeeeereees 27 28 UPS ee e a ee 9 UPS operation time ssssesssenssssesssersesssssrrsrrsssses 9 Usage MESSAGE ccccccececccececececeeeceeecececeeeeeeeeeeeses 167 V Version SUDCOMMANA ccsesesesessteteteteteee 371 153 VOIECONE oe eeceeseccccceceessssscecececeesesseceseeeceenentsaeees 132 W work area size CheECK ccccccececcceceeeececeeeceeeeeees 169
26. For GP7000F models 1000 2000 and PRIMEPOWER 800 1000 2000 WARNING FJSVscf _init ddi_soft_state_init failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf _init mod_install failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install 9F incorporates the driver into the system 70 Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING pci FISV scfc scfc scf_probe ddi_dev_nregs failed Meaning The register information in the SCF device is incorrect Action Check the state of the system board WARNING FJSVscf scf_attach ddi_get_iblock_cookie failed Meaning Failed to incorporate the SCF
27. H abhIns T directory output opt FJSVsnap bin fjsnap C H abhlns T directory D directory output DESCRIPTION fjsnap collects system data required to analyze faults OPTIONS Each option of the lower case letter specifies a group of data to be collected If omitted group information related to the basic systems is collected same as the b option A group that can be specified is displayed in the Usage message execute this command by specifying the H option The following options are available 167 H Displays the following Usage message Usage fjsnap H abhlns T directory output fjsnap C H abhlns T directory D directory output H Usage a all b basic software default h high availability l lp n network s Storage array T directory work directory C Add crash dump information D directory Savecore directory output ex dev rmt 0 k Collects all defined data j Collects group information related to the basic system G Collects group information related to high reliability Collects group information related to the printer i Collects group information related to the network 7 Collects group information related to the storage array T Specifies a work directory work area in the parameter directory If omitted a directory defined in environment variable TMPDIR is used as a work area This com
28. However at the cluster environment etc another node RCI address 0xXXXXXXXX which detected abnormality issues the panic instruction to this node via RCI And when OS panic is executed this node outputs this message Please investigate this node from information on another node RCI address OxXXXXXXXX WARNING FJSVscf cannot report PANIC Meaning Could not notify the system panic on the other HOST when it occurred paniclcpuX thread 0xXXXXXXXX FJSVscf memory dumping due to pressing REQUEST switc h Meaning Started saving memory dump due to the press of REQUEST switch 51 NOTICE FJSVscf pressed REQUEST switch in auto mode no memory dumping Meaning REQUEST switch was pressed but as the MODE switch is in AUTO position memory dump was not saved WARNING FJSVscf cannot send command due to SCF busy Meaning Failed to send commands due to busy status of the SCF device Action Check the state of the SCF device WARNING FJSVscf SCF error System Status Register XX unknown status Meaning The value of System Status Register was undefined value XX Action Check the state of the SCF device WARNING FJSVscf power supply unit failure BE Meaning Detected a BE power supply unit failure BE represents the power supply unit number Action Check the power supply unit that had its number displayed WARNING FJSVscf SCF went to offline mode again Meaning SCF entered the ONLINE state after resetti
29. In addition if the power down is only for a few seconds you may not want a system shutdown The system allows you to set the operation time following a power down This time is known as the UPS operation time UPS operation time is the length of delay prior to this software automatically starting the shutdown process It can be set from 0 second to 9999 seconds The default delay is 5 seconds If power returns within the UPS operation time the system will continue to operate UPS operation time is influenced by the UPS s capacity and specifications time required to shutdown the system UPS charge level and other factors Make sure you perform through tests before deciding on the appropriate UPS operation time When the following models are used SCF driver does not have the setting Set it by the Machine Administration Refer to the Machine Administration Guide for the setting method lt GP7000F model 1000 2000 PRIMEPOWER 250 450 650 800 850 900 1000 1500 2000 2500 HPC2500 1 3 2 4 Notes When GP7000 F model 1000 2000 or PRIMEPOWER 800 1000 2000 is used and the SCF driver package is installed reinstalling or updating it is necessary to set up the SCF driver again 1 4 Troubleshooting To protect the system from being damaged this software automatically shuts down and turns off power when the fan fails or an abnormal temperature is detected To protect hardware from damage it also immediately turns off power when power supply
30. Log at execution of this command including error information fisnap lsinf Attribute information of collect information file result of 1s 1 fjsnap result contents ST PROG FILE PHASE etc system 50 Uarp a ARP a 50 EB var nis 50 ST Collect result Space Collected normally EB A file to be collected was not found EP A collect procedure was not found NG The collect procedure has terminated abnormally PROG Collect procedure name For more information see 10 6Collection Procedure List FILE File and directory to be collected For more information see 10 5Collected Data List PHASE Collection order Standard 50 The data collection command arranges data to be collected in a work area uses compress 1 to compress each file and use tar 1 to write the compressed data to the output file Tar cfb output 20 work directory fjsnap d lt RETURN gt Forbidden file exclude All system data collected by this tool such as command execution result and files are defined in each group s collected data file under opt FJSVsnap etc directory If you forbid that this tool collects a part of these system data make a etc opt FJSVsnap exclude file With this method you can forbid that this tool collects the system data listed in 10 5 2Printer Related for example the printing data copied onto the spool area var spool lp temp In this case write a FILE field sec
31. MHz emory size 4096Mb Extended Interleave Mode Disable CPU Units Number Frequency Cache Size Version No MHz MB Impl Mask No MHz MB Impl Mask COSO00 CPU 0 675 8 0 4 0 7 COSOO0 CPU 1 675 8 0 4 0 7 COSO0 CPU 2 675 8 0 4 0 7 COSOO CPU 3 675 8 0 4 0 7 COSO1 CPU 0 675 8 0 4 0 7 COSO1 CPU 1 675 8 0 4 0 7 COSO1 CPU 2 675 8 0 4 0 7 COSO1 CPU 3 675 8 0 4 0 7 Used Memory Slot Number Size COSOO SLOT A00 256 COSOO SLOT BOO0 256 COSOO SLOT A01 256 COSOO SLOT BO1 256 COSOO SLOT A02 256 COSOO SLOT BO2 256 COSOO SLOT A03 256 COSOO SLOT B03 256 COSO1 SLOT A00 256 COSO1 SLOT BO0 256 COSO1 SLOT A01 256 COSO1 SLOT BO1 256 COSO1 SLOT A02 256 COSO1 SLOT BO2 256 COSO1 SLOT A03 256 COSO1 SLOT BO03 256 IO Cards Sub Freq 0 COMO0O PCI 00 scsi glm Symbios 53C875 33 0 COMOO PCI 01 SUNW hme pcil08e 1001 SUNW qsi cheerio 33 No failures found in System Initialization No Recent System Faults found Environmental Status MODE switch position is in LOCK mode System Temperature C AMBIENT 25 System PROM revisions RST 1 1 18 2001 08 22 22 24 POST 1 1 11 2001 08 28 10 03 Notes prtdiag 1M command offered in before ESF2 1 is offered by fjprtdiag 1M command in ESF2 2 or later When ESF2 2 or later is installed environment please use this command prtdiag 1M command is installed in usr platform uname i sbin directory However the display f
32. Meaning Failed to initiate SHUTDOWN procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start RCI POFF procedure xxx Meaning Failed to initiate RCI power down procedure xxx represents the system call that failed Action Allocate memory or a swap area etc rc0 d KOOFJSVscf scfreport shutdown was executed Meaning Reported the start of system shutdown to SCF device This message might be stored in message log var adm messages as daemon error However it is not abnormal 112 FJSVscf The system power down is executed 30 seconds later Meaning The power off of the system is begun 30 seconds later This message shows the state This message might be stored in message log var adm messages as daemon error However it is not abnormal 5 1 5 For PRIMEPOWER 650 850 900 1500 2500 HPC2500 pwrctrld power switch ignored Meaning The POWER switch was pressed but was ignored by the scftool 1M setting pwrctrld failed to start xxx Meaning Could not start the SCF monitoring daemon xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to open pwrctrld pid file Meaning Could not create the PID file Action Check the capacity of the root file system and whether it is mounted in a write enabled state pwrctrld halt system Meaning System shut down due to an error pwrctrld failed to start
33. NOTICE FJSVscf caught cpu watchdog alarm Meaning A CPU monitoring timeout occurred during CPU monitoring Action Allocate memory since there might not be enough kernel resources NOTICE FJSVscf device sense Sub Code Ox is not support Meaning The SCF device reported sensor information that is not supported by the driver 0x represents the sub code of the sensor information that was reported Action Check the state of the SCF device 48 WARNING FJSVscf scf cmd 0x incomplete Meaning The SCF device could not complete a command within the prescribed time 0x represents the command code that could not be completed Action Check the state of the SCF device WARNING FJSVscf scf cmd 0x failed SCF hard error Meaning The command could not complete successfully on the SCF device due to a hardware error 0x represents the command code that ended in an error Action Check the state of the SCF device WARNING FJSVscf scf cmd 0x failed SCF RCI error Meaning The command could not complete successfully on the SCF device due to an RCI error 0x represents the command code that ended in an error Action Check the state of the SCF device WARNING FJSVscf scf cmd 0x failed by unknown error yy Meaning The command could not complete successfully on the SCF device due to an undefined error 0x represents the command code that ended in an error and yy is the error code on the SCF device Action Check
34. RCI network detected When sub status is 0x82 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the cabinet type represents the cabinet number AAA will be displayed only if a cabinet type failure occurred on the following cabinet type Cabinet 0 Main Cabinet Cabinet l Expansion Cabinet Rack I O Rack P Cabinet Power Cabinet BBB represents the power supply unit name represents the power supply unit number BBB will be displayed only if a power supply unit failure occurred on the following power supply units SCF SCF Board FEP FEP CONV Converter SB System Board PCI BOX PCI BOX PCI DISK BOX PCI Disk BOX DTB DTB Data Transfer unit Board XB DDC Crossbar DDC Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x00 An abnormal power supply unit cannot be specified 0x01 04 Power supply and voltage are abnormal 0x05 Power supply unit which depends on device is abnormal OxYY is detailed information which supplements the event code OxZZ OxNN is a power supply unit type or number and it depends on the corresponding RCI device 0xMM shows the notified sense information and depends on the corresponding RCI d
35. SCF device SCFC path changed pci FJSV scfc scfc gt pci H FISV scfc scfc Meaning Detected SCF device failure Action Follow the instruction of the message displayed before this message WARNING FJSVscf SCF HALT was detected Meaning All SCF devices stopped After this message was displayed access to SCF device will be failed Action Follow the instruction of the message displayed before this message In addition confirm the state of the system board or the SCF device from System Console Software SCS for PRIMEPOWER 900 1500 2500 HPC2500 WARNING FJSVscf SCF ready interrupt occurred Meaning SCF device was changed 84 WARNING FJSVscf pci H FISV scfic scfc SCF command 0OxXXXX timeout Meaning The SCF command 0xXXXX could not complete a command within the prescribed time Action Check the state of the system board and SCF device WARNING FJSVscf pci FJSV scic scfc XXX register read error Meaning Recovered by re reading thought an I O register reading error occurred XXX is register name SCFI command SCFI Status SCFI tx data SCFI rx data SCFI control SCFI interrupt status Ebus 2 dma control DMA csr DMA address control DMA byte control ED write enable internal disk LED control WARNING pci FISV scfc scfc offline Meaning Detected SCF device failure Action Check the state of the system board an
36. This message shows the state However at the cluster environment etc another node RCI address 0xXXXXXXXX which detected abnormality issues the panic instruction to this node via RCI And when OS panic is executed this node outputs this message Please investigate this node from information on another node RCI address 0xXXXXXXXX NOTICE FJSVscf I O node status sense from RCI addr 0xXXXXXXXX sub status 0x62 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxYY OxYY OxYY Meaning Detected a sensed information of I O node status sub status 0x062 from RCI device addr OxXXXXXXXX This message displays the change of the state of this system or another device connected on the RCI network Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX When the RCI address is this system details of sense info become as follows OxZZ shows the event code 0x01 add 0x02 delete OxYY shows unit type and OxMM shows unit number 0x01 SCF SCF board 0x02 FAN 0x03 FEP 0x04 CONV Converter 89 0x05 SB System Board 0x06 PCIBOX or PCI Disk BOX 0x07 XB DDC Crossbar DDC OxNN shows cabinet type and cabinet number X 0x00 RCI I O device Ox2X Main Cabinet or Expansion Cabinet 0x06 Power Cabinet 0x07 I O Rack When the RCI address is another device details of sense info become as follows 0xZZ shows the event code 0x
37. Uls_alR_fonts Collects the result of ls alR var fonts Uls_alR_spl_lp Collects the result of ls alR var spool lp Uls_l_es Collects the result of ls l dev es Uvx1 Uvx2 Collects the information related to Volume Manager Uluxadm Collects the information related to SPARCstorage Ussa Array Umetal Collects the information related to Solstice Umeta2 DiskSuite Uraid Collects the information related to Raid Manager Ufire Collects the information related to Solstice FireWall 1 Ucl Collects the information related to SynfinityCluster icissiaeate Collects the information related to 8 8 Synfinity Cluster HA for Oracle Usdx Collects the information related to SynfinityDisk Usfx Collects the information related to SynfinityFile Wate Collects the information related to SynfinityFile Global Uscnet_error Collects the information related to Synfinity VIA z Collects the information related to AP Net Basic Uapnet_log S oftware Udspidem Ushowpsys Uideminf Collects the information related to IDCM Utrcidem Utrelzcs Udspigw Uinfgenigw Collects the information related to NETSTAGE Utransigw Unetcompo_nmc Collects the information related to Netcompo NMC 180 Server Uhrdconf Collects the result of hrdconf l Uisainfo Collects the result of isainfo kv Collects the core file informatio
38. When 3 Add a New License Password is selected on 11 4 2Top Menu the following screen appears Add a New License Server 1 NetWork Lock 2 Node Lock Please choose license type Cursor Key Move Cursor L Screen Redraw D QuitReturn Key End The license type depends on the software select the license type for the intended software 11 4 5 1 Registering Network Locked Products When 1 Network Lock is selected on 11 4 5Registering the License the following screen appears Add a New License Password Feature Name Version Number of Licenses License Password Expiration Date 1 jan 0___ Exit Please enter License Data Feature Name Cursor Key Move Cursor BS BackSpace X Delete a char AT Insert a char L Screen Redraw D Quit AR Clear Field Return Key End Input the feature name given by the software FEATURE name to Feature name If it has no name input the system product No When you input the parameters refer to the contents issued by Fujitsu License Password Distribution Center At the end move the display cursor to Exit then press the return key to complete the process 11 4 5 2 Registering Node Locked Products Node locked product means the software introduced with a node locked license Node locked license limits software for use only on a specified machine node When 2 Node Lock is selected on 11 4 5Registering the License the following menu
39. a A geese EN ne RA E 39 4 1 2 For GP7000F models 200 200R 400 400A 400R 600 600R and PRIMEPOWER ZOO AOOL GOO aea raare ene aerae RE AAEE cevenn zotals toute RAOS AEEA O RAE AEE E ERER EE RER 43 d t3 Eor PRIMEPOWER 250 450 arere eee A a A A A A a ete a A R T 58 4 1 4 For GP7000F models 1000 2000 and PRIMEPOWER 800 1000 2000 sssssssesssesssesssersseessrrsseesees 70 4 1 5 For PRIMEPOWER 650 850 900 1500 2500 HPC2500 sssssesssessssssserssressrsssrssssersseesserssresseesseesees 80 4 2 Disk Fault LED Drvar iesene reeet eieiei rnein aei karei ian haved siecie ck nance ch Hace detbsacee ev inte ce ane 92 4 3 SCSI Fault LED Driven oa AE E E N E E 94 4 4 FISV Wl DAVOT aa rea ETE AAE NE A E ERT NE N aes 98 4 5 Flash Update DiVersi ane e nA e ea aeaa e Eae e eea Aa A E aeea Eia aaar a 100 Chapter 5 Daemon Messages ccccceeccceceeeceeeteteceeetenereeeteteteceteneceneteterecetetereneteters 103 9 1 SGE Monitoring DaGmomvvicecccsctes eet ease ies Shee tease eee ee se aie 103 5 11 For BRIMEPOW ER csssfsccssecs e a a a a EE A Ea 103 5 1 2 For GP7000F models 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 aineen ie ee na eo e i aa aaa EEE a EE EEE AO EEE T E OESE ERE S GEREGEN 105 5 1 3 For PRIMEPOWER 250 450 e neina n a a a a a T en 108 5 1 4 For GP7000F models 1000 2000 and PRIMEPOWER 800 1000 2000 sssssssesssesssesssssssrrsserssresses 111 5 1 5 For PRIMEPOWER 650 850 900 1500 2500 HPC2500 oes cescceesceceseeeeneeceneeeeaeeceeeeeaeecen
40. and operational status It then outputs all to a tape unit etc approx 200 types and 2 000 files This tool only executes commands for copying and referencing files and uses the tmp file system as a work area default The collected data is only compressed and its contents can be analyzed using the existing commands for each type of information If a system fault occurs use this tool to collect system information when the execution of a command becomes possible for example when reboot was completed after system dump was collected Over time data so acquired to analyze faults may be erased It is recommended that you execute this tool as a superuser Note When the system reboots after it has crashed Crash Dump Assistantinvokes this tool and automatically saves a system data file named fjsnap X into the same directory as the crash dump But if Savecore directory is defined as a directory other than the default directory var crash uname n on Solaris 2 6 OE Crash Dump Assistant does not save system data automatically 10 2 Collection Time and Collection Capacity Collection time takes about 10 to 15 minutes Collection capacity is between 3 to 30 Mbytes These values vary depending on the number of installed products packages 10 3 Target System The target systems are shown below lt Solaris 2 6 OE and later 10 4 Command Reference NAME fjsnap System data output tool FORMAT opt FJSVsnap bin fjsnap
41. appears Add a New License Password Feature Name Version Number of Licenses 0 License Password Expiration Date 1 jan 0___ HostID of Node Lock 188 Exit Please enter License Data Feature Name Cursor Key Move Cursor BS BackSpace X Delete a char AT Insert a char L Screen Redraw D Quit AR Clear Field Return Key End Input the feature name given the software FEATURE name to Feature Name If it has no name input the system product No When you input the parameter refer to the contents issued by Fujitsu License Password Distribution Center Number of License has already been set to 0 do not change the contents At the end move the display cursor to Exit then press the return key to complete the process 11 4 6 Changing the License To update the contents registered in a license use Change an Entry When 4 Change a License Password is selected on 11 4 2Top Menu the following screen appears Change an Entry A List of Features License Data 1 fn1 Version 2 999 2 fn2 Number of Licenses 0 3 fn3 License Password 3B5AA0F13E58142E5FFF Expiration Date 1 jan 0 Node Lock Hostid 80f12081 Please choose a feature name Cursor Key Move Cursor L Screen Redraw D Quit p Previous Page n Next Page Return Key End s Top Page e Bottom Page U UNDO The licenses registered in the license file are displayed in A List of Feat
42. become complicated processing 1 6 kernel parameter of SCF driver 1 6 1 For SynfinityCluster When using SynfinityCluster you need to set the SCF RCI monitoring timeout in the kernel parameter letc system according to RCI connecting unit model or the number of partitions Notes The monitoring timeout might need to be set for some RCI connecting unit without partitions You can calculate the timeout using the largest number of partitions in an RCI connecting unit When the timeout setting is done reboot a node and manually set the SynfinityCluster parameter failure detection monitoring time See 5 3 Alert monitoring interval of the SynfinityCluster Installation Administration Guide Model with partitions See Condition a Model 800 1000 and 2000 Model without partitions See Condition b Cluster system with 4 or more nodes except the above a For GP7000F model 200 200R 400 400A 400R 600 600 and PRIMEPOWER200 400 600 The monitoring timeout setting is not required For PRIMEPOWER 250 450 Set 2 seconds for the monitoring timeout Setting up the etc system file Change the etc system file on all cluster nodes as follows 1 Copy or backup etc system using etc system org Example cp etc system etc system org 2 Add the following to etc system As the timeout is set up in s units set a value equal to the value calculated above multiplied by 1000000 set FJSVscf scf_rdctrl_sense_w
43. console path may use for only the FJVTS and SunVTS The usable default devices for FJVTS and SunVTS are dev term fa003 fa004 and dev se_hdlc3 se_hdlc4 7 3 2 PRIMEPOWER 900 1500 2500 HPC2500 The device name of the serial port will be dev term fa001 dev term fa002 etc Because the number of this device name is allocated from the instance number of driver this number does not necessarily correspond to the slot number of the system board Do not change the setting of port monitor etc to the serial port for the console Because the physical device of the serial port used for the console is the physical device path which are linked from logical device under dev fjse directory the logical devices under dev term and dev cua and dev se_hdlcX files which link to above mentioned physical device path are devices used for the console Except for the serial port for consoles five serial ports can be used by the user However keep in mind that it is necessary to stop beforehand the application which is using the serial port of the system board or the PCI Disk BOX in order to disconnect the system board by DR The devices which is not used as the console path may use for the FJVTS and SunVTS 7 4 The Duplicated OS Console Solaris 8 OE or later This section explains about the IOMP O MultiPathing and DR Dynamic Reconfiguration features composing the duplicating function of the console path where the serial port driver
44. device was repeated fifteen times due to RCI device BUSY on the SCF device But they were not processed normally OxX3XX Sending a command to SCF device due to th rror on the command Interface with the SCF device OxX8XX The command and sub command that it was sent to the SCF device was not supported OxX9XX The command that it was sent to the SCF device failed with the parameter 60 error OxXBXX The device specified with the address for the command that it was sent to the SCF device does not exist on the RCI network or RCI is inactive OxXCXX The command that it was sent to the SCF device failed with the access error to hardware OxXDXX The command that it was sent to the SCF device failed with the violation of the execution condition OxXEXX The command that it was sent to the SCF device failed with the BUFFER FULL Action Check the state of the SCF device WARNING pci H FISV scfc scfc XXX register parity error Status register OxYYY Y Meaning Parity error interrupt occurred to the XXX register read OxYYYY represents the XXX register XXX is register name SCF command status SCF interrupt status SCF interrupt mask SCF mode sw SCF length Action Check the state of the system board and SCF device WARNING FJSVscf SCF HALT was detected Meaning All SCF devices stopped After this message was displayed access to SCF device will be failed Ac
45. driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_ioctl ddi_get_soft_state failed Meaning Could not ioctl the FJSVfupd driver due to the abnormal termination of ddi_get_soft_state 9F allocates 101 an area for the driver Action Allocate memory since there might not be enough kernel resources 102 Chapter 5 Daemon Messages This chapter gives the meaning of messages displayed by SCF Monitoring daemon of each model It also describes what to do when you get error messages The system call error messages listed below are described by man s 2 Intro 5 1 SCF Monitoring Daemon Please refer to the message of the corresponding model for SCF Monitoring message 5 1 1 For PRIMEPOWER 1 pwrctrld Power switch is pressed Press power switch again within 5 seconds to start shutdow n procedure Meaning The POWER switch was pressed Pressing it again within five seconds starts the shutdown process pwrctrld power switch ignored Meaning The POWER switch was pressed but was ignored by the scfconf 1M setting pwrctrld failed to start xxx Meaning Could not start the SCF monitoring daemon xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to open pwrctrld pid file Meaning Could not create the PID file Action Check the capacity of the root file system and whether it is mounted in a write enabled state pwr
46. each partition becomes effective For example When Single is specified for a certain partition and Double is specified as for another partition and if power switch is pushed only once as for the partition which specifies Single the shutdown is done 23 SEE ALSO scfdate 1M 3 5 scfconf 1M NAME scfconf CUI controlling SCF features SYNOPSYS For PRIMEPOWER 1 opt FJSVhwr sbin scfconf p 1 2 off For GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 opt FJSVhwr sbin scfconf p 1 2 offt be tscf tod u timel AVAILABILITY FJSVscu FJSViscu DESCRIPTION scfconf controls the following SCF features The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER 1 200 400 600 Power switch settings Number of times in which power switch until the shutdown beginning is pushed can be set The setting can select 1 one time 2 two times or offGgnore The default setting is 2 After power switch has been pressed twice the shutdown process is started System clock settings Specifies whether it is preferred to use the system standard clock or to adjust the time of the system standard clock using the SCF high resolution clock that has a lower degree of error The following models can use this setting GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 The setting can select scf or tod The default
47. for status information ONLINE Power is being supplied OFFLINE Power is not being supplied BROKEN Disk controller is not responding or disk is not installed NOTE You must specify a path name containing a disk slice identifier that is assigned to the existing disk slice 1 Controller specified Example Installed target 0 2 3 4 diskadm display c0 Controller is device c0 Device Status Targeto Target2 Target3 Target4 ONLINE OFFLINE ONLINE ONLINE Targets corresponding to existing device path are displayed 2 Disk specified Example Installed target 0 3 diskadm display dev rdsk cO0t0d0s2 dev rdsk cO0t3d0s2 Controller is device Device Status Targeto Target3 ONLINE OFFLINE NOTES Only the super user can execute this command EXIT STATUS This command returns the following values 0 Ended normally 1 Error 22 3 4 scftool 1M NAME scftool GUI controlling SCF features SYNOPSYS opt FJSVhwr sbin scftool AVAILABILITY FJSVscu FJISVscu2 DESCRIPTION scftool is a GUI tool for controlling the following SCF features The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R 1000 2000 PRIMEPOWER 200 400 600 800 1000 2000 Power switch settings Number of times in which power switch until the shutdown beginning is pushed can be set The setting can select Single 1 time Double 2 times or ignore The default
48. has not been damaged diskadm path name disk not responding Meaning Disk controller is not responding or disk is not installed Action Check if the disk is installed correctly Check if disk controller is working correctly 122 Warning Cannot Istat file name Meaning File lstat 2 failed File name is the file under dev rdsk Action Check the dev rdsk directory Warning file name is not a symbolic link Meaning A file other than a symbolic link is in the dev rdsk directory Action There is problem with the dev rdsk directory Reboot the system using boot r Warning path name already started but trying again Meaning The device is already booted but diskadm is trying again Warning path name already stopped but trying again Meaning The device is already stopped but diskadm is trying again diskadm dev FJSVhwr opendir failed System call error message Meaning dev FJSVhwr opendir 3C failed Action Make sure that the SCF driver package is installed properly diskadm ioctlQ SFLED_IOC_LIST failed System call error message Meaning ioctl 2 to the SCSI Fault LED device driver failed Action Check the state of SCSI Fault LED device diskadm ioctl SFLED_IOC_OFF failed System call error message Meaning ioctl 2 to the SCSI Fault LED device driver failed Action Check the state of SCSI Fault LED device diskadm ioctlQ SFLED_IOC_ON failed System call error message M
49. l var yp binding Uls_l_ dev_rdsk Collects the result of ls 1 dev rdsk Uls_l_patch Collects the result of ls l var sadm patch Uls_l_platform Collects the result of ls l platform arch k kernel Uls_l_sendmail Collects the result of ls l usr lib sendmail Uls_l_uname_n Collects the result of ls 1 Savecore directory or ls 1 var crash uname n Uls_ld_sadm Collects the result of ls ld var sadm Umodinfo Collects the result of modinfo Unetstat_a Collects the result of netstat a Unetstat_an Collects the result of netstat an Unetstat_i Collects the result of netstat i Unetstat_k Collects the result of netstat k Unetstat_m Collects the result of netstat m Unetstat_p Collects the result of netstat p Unetstat_pn Collects the result of netstat pn Unetstat_r Collects the result of netstat r Unetstat_rn Collects the result of netstat rn Unetstat_s Collects the result of netstat s Unfsstat Collects the result of nfsstat Unfsstat_m Collects the result of nfsstat m Unisshowcache_v Collects the result of nisshowcache v Upkginfo_i Collects the result of pkginfo i Upkginfo_l Collects the result of pkginfo l Upkginfo_p Collects the result of pkginfo p Uplatform_drv_conf Collects the files of platform arch k kernel drv conf Uprtconf_V Collects the result of prtco
50. lamp of the Main Cabinet can be lit or blinked Refer to the nodeled 1M command For models not listed above The CHECK LED will either blink or light constantly when there is a failure in some portion of the system hardware If a fatal error occurs on the system the CHECK LED will light constantly and Solaris OE will not boot up even if you turn on power Degraded operationoccurs when there is a failure in some portion of the system hardware rendering the failed hardware unusable The CHECK LED will blink while the system is under degraded operation The fjprtdiag 1M command displays information on failed hardware 1 2 3 3 LCD Panel When PRIMEPOWER 1 250 450 are used this section need not be referred While Solaris OE is running the LCD Panel on the processing unit s operation panel displays the node name of the system When a failure occurs on the system the LCD panel displays hardware information For more information refer to PRIMEPOWER USER S MANUAL or GP7000F USER S MANUAL 1 2 3 4 Other Switches The operation panel also contains the REQUEST and RESET switch These switches are not used during normal operation The RESET switchresets the system It only works when the MODE switch is set to MANUAL MAINTENCE Normally the operation by which RESET switch is pressed is prohibited However please execute the memory dump save by REQUEST switch when it is necessary to reset the system by an unexpected situation After the
51. memory dump is saved the system is reset It only works when the MODE switch is set to MANUAL MAINTENANCE This operation is only for maintenance purposes and problem analysis and improper use can cause the destruction of the system Please do not operate of the REQUEST switch except when the system should save the memory dump by the purpose of an abnormal state or problem analysis The memory dump might fail to be saved in some system conditions 1 2 4 Shutting Down and Booting the System The system executes the shutdown process just like an operator in case of a system failure a manipulation of the Auto Power Control System or the occurrence of other potential events If a UPS Uninterruptible Power Supply is connected the system can also execute the shutdown process if a power down occurs Whether the system will normally power on after a power down depends on the following conditions The power to the system is cut according to the shutdown instruction of the operator executing shutdown i5 the settings in the Auto Power Control System or shutdown due to system failure Following a power down when power is restored the system will automatically power on But this will not occur if a system failure occurred during the shutdown process Normally the system reboots after the shutdown according to the reboot instruction executing shutdown i6 of the operator If a power down or a system failure occurs during the shutdown pro
52. mt 1 mt f nrinput fsf 1 lt RETURN gt tar xf nrinput lt RETURN gt For nrinput specify a special file name of non rewinding tape device EXIT STATUS When an error occurred during data collection a diagnosis messageis written to the fjsnap elog file the erroneous information is skipped and the next information processing is continued This command returns the following values 0 Ended normally 1 Ended abnormally 2 Invalid command syntax 3 Re executed during execution of this command FILES work directory fjsnap d fjsnap result work directory fjsnap d fjsnap elog work directory fjsnap d fjsnap lsinf NOTES Do not re execute this command during execution of this command The load on the disk unit containing the work area temporarily increases to about 80 to 90 If this disk load causes problems in operation reserve a work area on a file system on a disk unit not used by applications and systems The system information is inaccessible by non privileged users It is recommended that you execute this tool as a superuser For more information see 10 7Restricted System Information 10 5 Collected Data List The collected data in this section Basic System related Printer related High reliability related Storage array related Network related 10 5 1 Basic System Related The Basic System related collected datais shown below Hardware configuration Software configuration
53. on RCI addr 0xXXXXXXXX was detected sub status 0xX5 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected a power supply end of UPS sub status 0x05 or 0x85 of RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 UPS became an electrical discharge end voltage OxYY is UPS number and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of UPS connected with the RCI device displayed with addr UPS battery is charged or please contact our customer engineer 78 WARNING FJSVscf UPS failure on RCI addr 0xXXXXXXXX was detected sub status Ox X5 sense info OxXX OxXX OxXX 0xXX 0xZZ OxYY OxYY 0x00 Meaning Detected a UPS failure sub status 0x05 or 0x85 of RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings
54. package is installed properly 139 6 23 iompadm 1M command iompadm cannot initilize library Permission Denied Meaning The initialization failed because the command was executed using user privileges other than root Action Execute the command using root user privileges iompadm cannot initilize library No Memory Meaning The initialization failed due to insufficient memory Action Allocate memory and execute the command again iompadm Too many classes specified Invalid Arguments Meaning A class was specified more than once Action Check the format of the command iompadm invalid command Invalid Arguments Meaning There is an error in the way a subcommand name was used Action Check the format of the command iompadm cannot initilize library Invalid Path Meaning There is no valid Plug In or initialization is failed in all the Plug In Action Make sure that the driver is installed properly In the case driver installed properly call a Fujitsu customer engineer iompadm XXX Invalid Arguments Meaning There is an error in the way the specified option subcommand or parameter was used Action Check the format of the command 140 iompadm XXX No Memory Meaning Insufficient memory occurred during the command execution Action Allocate memory and execute the command again iompadm XXX Invalid Path Number Meaning The path was added deleted to the same class by another proce
55. socion rescris i a 191 B DOO inann a a a E T ates 3 C changing PATH liissi tos pehioi donemi pariri ae eaea 6 changing the license ccccceceseseeeeeeeeeeeeeeees 189 CHECK LED re hodate eacstesansttend cootadecesicaeates hed Collect data Check riseire 169 collect data reference cccccccccceceesesssceeececeees 171 collect data size Check cccccececeseeeeeeeeeeeeees 169 Collected data ccccccececeeeeees 171 176 177 178 collection procedure list ccccceceseeeeeeeseeeeees 178 Connecting the Console ccccssccceesseeeeeeees 145 Crash Dump Assistant ccccscscccceceeeesssseeeeees 167 CULSES BX inh E eos 186 D data collection rr 169 AOD eona aE oad degraded operation 006 deleting the license 06 deleting the license server diagnosis message Disk Fault LED Driver diskad Mi 2 rta an diskadm 1M cccceeeeseseeeeees display pathname 00 DR roro e n Ree DR Connection Script cc ccccccceeeesseeeees E entering the OpenBoot environment 65 5 Error MESSAGE eere eT E EEEE AT 192 201 Expansion Disk Cabinet Expansion File Unite ees Bg in He ee 13 F features and structures offered by the serial port casa ccc ei EEE NETES 145 features offered by the main cabinet 005 3 featUre g Seer riava ions nice niids iat che et 146 fims Driver lt iiss nce a Nike need L57 fsa pon a e a e
56. supply failure occurs THRM LED Lit constantly when abnormal temperatures occur FAN LED Lit constantly when fan failures occur Blinking or lit constantly when other SOFT LED PRIMEPOWER1 only failures occur Refer to Machine Administration Guide If any ALARM LEDs blink or light up constantly the CHECK LED will also blink or light up in the same way Each FAULT DISK LED will stay lit while hot swapping internal disks If a fatal error occurs on the system these LEDs will stay lit and Solaris OE will not boot up even if you turn on the power Degraded operationoccurs when there is a failure in some portion of the system hardware rendering the failed hardware unusable These LEDs will blink while the system is under degraded operation The fjprtdiag 1M command displays information on failed hardware For PRIMEPOWER 250 450 The CHECK LED will either blink or light constantly when there is a failure in some portion of the system hardware If a fatal error occurs on the system the CHECK LED will light constantly and Solaris OE will not boot up even if you turn on power Degraded operationoccurs when there is a failure in some portion of the system hardware rendering the failed hardware unusable The CHECK LED will blink while the system is under degraded operation The fjprtdiag 1M command displays information on failed hardware In PRIMEPOWER 250 450 to specify target processor at maintenance etc the CHECK
57. switch WARNING FJSVscf kstat memory allocation error Meaning There is not enough memory Action Allocate memory since there might not be enough kernel resources FJSVscf ignoring debug enter sequence Meaning STOP A was entered while the MODE switch on the operator panel was set to LOCK FJSVscf allowing debug enter Meaning STOP A was entered 4 2 Disk Fault LED Driver NOTICE FJSVfled ddi_poke8Q failed Meaning ddi_poke8 9F failed during probe Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled ddi_regs_map_setup failed Meaning ddi_regs_map_setup 9F failed during probe or attach Action Allocate memory since there might not be enough kernel resources 92 NOTICE FJSVfled fled_probe failed Meaning probe failed Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled ddi_create_minor_node failed Meaning ddi_create_minor_node 9F failed during attach Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled ddi_soft_state_zallocQ failed Meaning ddi_soft_state_zalloc 9F failed during attach Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled ddi_get_soft_stateQ failed Meaning ddi_get_soft_state 9F failed during resume or getinfo Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled fl
58. system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Supply Unit failure procedure xxx Meaning Failed to initiate power supply unit failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start FAN failure procedure xxx Meaning Failed to initiate FAN failure procedure xxx represents the system call that failed Action Allocate memory or a swap area 114 pwrctrld failed to start THERMAL alarm procedure xxx Meaning Failed to initiate THERMAL alarm procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Off procedure xxx Meaning Failed to initiate Power Off procedure xxx represents the system call that failed Action Allocate memory or a swap area etc rc0 d KOOFJSVscf scfreport shutdown was executed Meaning Reported the start of system shutdown to SCF device This message might be stored in message log var adm messages as daemon error However it is not abnormal FJSVscf The system power down is executed 30 seconds later Meaning The power off of the system is begun 30 seconds later This message shows the state This message might be stored in message log var adm messages as daemon error However it is not abnormal 115 116 Chapter 6 Command Messages This chapter gives the meaning of messages di
59. the state of the SCF device WARNING FJSVscf SCF hardware error was detected error status register value Meaning SCF hardware error occurred Action If this message was issued repeatedly check the SCF device FJSVscf kstat_create failed Meaning kstat_create failed Action Allocate memory since there might not be enough kernel resources FJSVscf switch status is unknown Meaning There is a problem with the panel switch setting Action Check the state of the SCF device 49 FJSVscf kstat memory allocation error Meaning There is not enough memory Action Allocate more memory WARNING FJSVscf no devise sense interrupt status 1 register xx Meaning An interruption that should have sensed information was detected but no sensed information was got xx represents the value in the interrupt status 1 register Action Check the state of the SCF device WARNING FJSVscf Unexpected interrupt interrupt status 1 register xx Meaning An undefined interruption was detected xx represents the value in the interrupt status 1 register Action Check the state of the SCF device WARNING FJSVscf SCF HALT was detected halt status register xx Meaning SCFHALT was detected xx represents the value in the halt status register Action Check the state of the SCF device WARNING FJSVscf scf cmd 0x failed SCF buffer full yy times repeated Meaning Sending a command to SCF device was repeated yy tim
60. this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI BE represents the BE power supply unit number Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x05 BE power supply unit which depends on device is abnormal OxYY is detailed information which supplements the event code OxZZ OxNN is a BE power supply unit type or number and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the power supply unit of the BE and please contact our customer engineer WARNING FJSVscf power supply unit failure on RCI addr OxXXXXXXXX sense info OXXX OxXX OxXX 0xXX 0xZZ 0xZZ OxZZ 0xZZ Meaning Detected a power supply unit except FEP and BE failure on RCI device addr OxXXXXXXXX This message displays abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the notified sense information and depends on the co
61. to requested path Meaning Could not change the communication path in the state active to another path due to the abnormal state since another path is not in the state standby Action Make sure that a communication path in the state standby exists Use the iompadm command to enter the state standby when communication paths in the state other than active are stopped Call a Fujitsu customer engineer when this trouble is not solved WARNING FJMSE 5039 Message Classifing Error Meaning Detected an internal error regarding data classifying Action Call a Fujitsu customer engineer 162 WARNING FJMSE 5040 Invalid path status Meaning Detected an internal error regarding status control of communication paths Action Call a Fujitsu customer engineer WARNING FJMSE 5041 Free High Priority Message by unlinking Lower Path Meaning Detected an internal error regarding delete of the communication path Action Call a Fujitsu customer engineer NOTICE FJMSE 5100 Active path change to path gt dev fjse X Meaning The communication path of active status changed to dev fjse X Action If a console message of the se driver such as pci xx xxxx ebus 1 FJSV se 14 400000 b se offline XXXX Register read error was displayed before this console message displayed or the status fail is displayed after you execute the iompadm c fjmse info command a hardware error might be occurred Call a Fujitsu customer engineer
62. type represents the unit number BBB will be displayed only if a unit failure occurred on the following units FANTRAY Fan tray PCI BOX PCI BOX PCI DISK BOX PCI Disk BOX CCC represents the fan unit represents the fan unit number CCC will be displayed only if a fan unit failure occurred on the following units FAN fan unit PSU PSU or fan unit of the PCI BOX or PCI DISK BOX Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Fan rotation decrease 0x02 Fan rotation stop OxYY is fan number and the number which depends on the corresponding RCI device OxNN is fan tray number and the number which depends on the corresponding RCI device 0xMM shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the fan unit of the CCC and please contact our customer engineer 86 WARNING FJSVscf power supply unit failure on RCI addr 0xXXXXXXXX AAA BBB s ub status 0xX2 sense info 0xXX OxXX OxXX 0xXX 0xZZ OxYY OxNN 0xMM 0xMM Meaning Detected a power supply unit failure sub status 0x02 or 0x82 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the
63. variables and they need to be set as the system board which surely exists in the partition If the system boards defined as tty conspath and tty sub conspath do not exist in the partition the serial port of the system board on which the smallest number in a partition was attached will turn into a serial port for consoles However the value of tty conspath and tty sub conspath are not changed Please also refer to the following documents about a setup about console connection PRIMEPOWER USER S MANUAL GP7000F model 1000 USER S MANUAL GP7000F model 2000 USER S MANUAL System Console Software User s Guide 7 4 8 Management command When there are no abnormalities for a system it is not necessary to perform operation of IOMP or DR of the console path The iompadm 1M command is used for a certain reason to change the state of IOMP This command is contained in FJSViomp package Please refer to a Dynamic Reconfiguration User s Guide about the command about DR function Moreover refer to Chapter 8 Command Reference for the details of the iompadm 1M command supported by IOMP of a console path 7 4 4 Messages See Chapter 9 Messages for information about console messages displayed by the fjmse driver iompadm 1M command and the DR connection script 147 148 Chapter 8 Command Reference This chapter describes the commands offered by this software 8 1 iompadm 1M NAME iompadm multi path contr
64. wrong with the inside of the unit WARNING FJSVscf power supply unit failure Meaning Detected a power supply unit DDC failure Action Check the power supply unit WARNING FJSVscf fan unit failure on power supply unit Meaning Detected a fan unit failure on power supply unit Action Check the fan unit of power supply unit 42 paniclcpuX thread 0xXXXXXXXX FJSVscf memory dumping due to pressing REQUEST switc h Meaning Started saving memory dump due to the press of REQUEST switch 4 1 2 For GP7000F models 200 200R 400 400A 400R 600 600R and PRIMEPOWE R 200 400 600 WARNING FJSVscf _init ddi_soft_state_init failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf _init mod_install failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install 9F incorporates the driver into the system Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_get_so
65. 00 600 and PRIMEPOWER200 400 600 The monitoring timeout setting is not required For PRIMEPOWER 250 450 The monitoring timeout setting is not required For GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 Set up the monitoring timeout in the etc system file as follows Calculating monitoring timeout lor 2 nodes 2 seconds 3 or more partitions 1 second 0 5 x number of partitions Example 1 8 partitions 2 5 seconds Example 2 4 partitions 3 0 seconds Setting up the etc system file Change the etc system file on all cluster nodes as follows 1 Copy or backup etc system using etc system org Example cp etc system etc system org 2 Add the following to etc system As the timeout is set up in s units set a value equal to the value calculated above multiplied by 1000000 set FJSVscf2 scf_rdctrl_sense_wait monitoring timeout s unit For example etc system is specified for 2 partition configuration as follows set FJSVscf2 scf_rdctrl_sense_wait 2000000 3 Reboot the system For PRIMEPOWER 650 850 The monitoring timeout setting is not required For PRIMEPOWER 900 1500 2500 HPC2500 Set up the monitoring timeout in the etc system file as follows Calculating monitoring timeout lor 2 partitions 2 seconds 3 or more partitions 1 second 0 5 x number of partitions Example 1 3 partitions 2 5 seconds Example 2 4 partitions 3 0 seconds Setting up the etc
66. 00A 400R 1 0o 250 450 900 1500 PRIMEPOWER 2500 HPC2500 PRIMEPOWER 800 1000 2000 200 400 600 fiprtdiag 1M O O O O O hsadm 1M O O X X X diskadm 1M O O O O 0 scftool 1M X 0 X 0 X scfconf 1M O 0 X X X scfdate 1M X O X X O 1 scfwdtimer 1M O X X X X rcihello 1M X O X X X rciinfo 1M X O O O O rcinodeadm 1M X O X X X rciopecall 1M X O O O O nodeled X X O X X iompadm 1M X X O O O prtdiag 1M 2 2 2 2 2 O offer X Unoffer 1 There is a condition in the command operation on each model 2 SCF driver is not offering this command from ESF2 2 3 1 fjprtdiag 1M NAME fjprtdiag Prints system diagnostic information SYNOPSYS lopt FJSVhwr sbin fjprtdiag v 1 AVAILABILITY FJSVscu FJSVlscu FJSVpscu FJSVscul FJSVscu2 FJSVscu3 DESCRIPTION fjprtdiag displays system configuration information and system diagnostic information System diagnostic information includes information on degraded devices caused by failures The interface output format and installation location may change in future releases 15 OPTIONS By default fjprtdiag displays the following information lt System Configuration lt System clock frequency Memory size Extended interleave mode for PRIMEPOWER 650 850 900 1500 2500 HPC2500 CPU Units Used Memory Unused Memory Displays when there is partial failure in memory used IO Cards Failed Units in System Initialization
67. 00A 400R 600 600R and PRIMEPOWER 200 400 600 u time time Specifies the length of delay in seconds until this software starts the shutdown process This specification is specifiable with GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 EXAMPLES opt FUISVhwr sbin scfconf p off c scf NOTES Only the super user can execute this command EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error SEE ALSO scfdate 1M scftool 1M 3 6 scfdate 1M NAME scfdate Checks the SCF high resolution clockand synchronizes with the system standard clock SYNOPSYS opt FJSVhwr sbin scfdate sync AVAILABILITY FJSVscu FJSVscu3 DESCRIPTION scfdate checks the SCF high resolution clock and then reads the time of the system standard clock in order to reset the SCF high resolution clock The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER 200 400 600 650 850 Running this command without any arguments displays the current time of the SCF high resolution clock Specifying the sync option sets system time from the system standard clock to the SCF high resolution clock Even if this command is offered to PRIMEPOWER 900 1500 2500 HPC2500 and specifies the sync option operation is invalid 25 EXAMPLES prompt scfdate Tue Oct 27 18 40 38 JST 1998 date 1157 Tue Oct 27 11 57 00 JST 1998 scfdate sync Tu
68. 01 RCI I O device connection or power supply reentry 0x02 RCI I O device disconnect OxYY is type or number of RCI I 0O device and it depends on corresponding RCI I 0O device Action It is not necessary This message might be output in this system at maintenance When this message is frequently displayed it is necessary to investigate Please contact our customer engineer WARNING FJSVscf device sense from RCI addr 0xXXXXXXXX sub status OxYY sense info OXXX OxXX OxXX 0xXX 0xZZ 0xZZ OxZZ OxZZ 0xZZ Meaning Detected a sensed information form RCI device addr 0xXXXXXXXX that SCF driver does not support or undefined This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI OxYY shows the event code notified the SCF driver Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows notified sense information and is an irregular value Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please contact our customer engineer When RCI device is this system check whether to operate about Machine Administration WARNING FJSVscf UPS low battery on RCI addr 0x
69. 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x02 UPS hardware failure 0x03 UPS battery failure 0x04 UPS circuit protector failure OxYY is UPS number and detail information and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of UPS connected with the RCI device displayed with addr Check to make sure that nothing is wrong with the UPS or please contact our customer engineer WARNING FJSVscf cannot report PANIC Meaning Could not notify the system panic on the other HOST when it occurred WARNING FJSVscf scf_map_regs ddi_dev_regsize failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_regsize 9F gets the register size Action Check the state of the SCF device WARNING FJSVscf scf_map_regs ddi_regs_map_setup failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources 91 WARNING FJSVscf kstat_create failed Meaning kstat_create 9F failed Action Allocate memory since there might not be enough kernel resources NOTICE FJSVscf switch status is unknown Meaning There is a problem with the panel switch setting Action Check the state of the panel
70. 1 Meaning In a license file the start date of the license is inconsistent with the ending date Action Check the contents of the license file Determine whether Check that the correct password is input Reacquire a license Invalid returnrd data from license server Error code 12 Meaning A port number is invalid or the vendor daemon is not responding Action Check the port number of etc services If it is correct reinstall the package No SERVER lines in license file Error code 13 Meaning The license file does not contain a SERVER line definition Action Include a SERVER line in the license file Cannot find SERVER hostname in network database Error code 14 Meaning etc hosts does not describe the license server defined in the SERVER line Action Define the license server correctly Cannot connect to license server Error code 15 Meaning It is impossible to communicate with the license server Action Check the following If no solution is found call a Fujitsu customer engineer Are the license daemon and the vendor daemon running Is the license server connected to the network Is there any abnormality in the license file Cannot read data from license server Error code 16 194 Meaning It is impossible to read data from the license server Action Reboot the license server Cannot write data to license server Error code 17 Meaning It is impossible to write data after a
71. 2 to the Fault LED device driver failed and the write to or read from a register failed Action Make sure that the SCF driver package is installed properly diskadm ioctlQ FLED_IOC_POWER_GET failed System call error message Meaning ioctl 2 to the SCF driver failed and the write to or read from a register failed Action Make sure that the SCF driver package is installed properly diskadm strdup Q failed System call error message Meaning strdup 8C failed Action Allocate memory or a swap area 121 diskadm malloc Q failed System call error message Meaning malloc 3C failed Action Allocate memory or a swap area diskadm dev rdsk opendir failed System call error message Meaning devirdsk opendir 3C failed Action Check the dev rdsk directory diskadm getcwd failed System call error message Meaning getcwd 3C failed Action Use fsck 1M to make sure that the root file system has not been damaged diskadm path name Istat failed System call error message Meaning Istat 2 failed Action Use fsck 1M to make sure that the root file system has not been damaged diskadm path name readlink failed System call error message Meaning readlink 2 failed Action Use fsck 1M to make sure that the root file system has not been damaged diskadm path name chdir failed System call error message Meaning chdir 2 failed Action Use fsck 1M to make sure that the root file system
72. 850 900 1000 1500 2000 2500 HPC 2500 OPTIONS The following options are available c calss name Specifies a class name For PRIMEPOWER 250 450 FJSVscf must be specified For GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 FJSVscf2 must be specified For PRIMEPOWER 650 850 900 1500 2500 HPC2500 FJSVscf3 must be specified p Displays a communication path s logical and physical device name If this option is omitted only the logical device name will be displayed Subcommand Table 3 1 Subcommand List lists the subcommands you can specify and gives their descriptions Table 3 1 Subcommand List Subcommand Description Displays the configuration information of the specified interface or all interfaces and the status of communication paths info Displays the status of the specified tat ar ae communication path Displays the class to which the specified ident Cota Da communication path belongs Displays the interface to which specified b rae pees communication path belongs Restores the specified communication recover path After the recover subcommand is running this subcommand makes the specified communication path available for communicating start Displays the version information for this version product Displays the usage of the iompadm help command 32 Parameter Specifies a parameter in combination with the subcommands F
73. Detected Recent System faults The following options are available V Verbose mode Additionally displays detailed information that is environment information and OBP version information System Temperature is not displayed in the following models PRIMEPOWER 1 GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 PRIMEPOWER 900 1500 2500 HPC2500 Log output Outputs information to syslogd 1M only when failures and errors occur on the system If it is specified along with v detailed information is always output to syslogd 1M EXAMPLES For PRIMEPOWER 1 opt EJSVhwr sbin fjprtdiag 6 System Configuration Fujitsu PFU sun4u Fujitsu PRIMEPOWER 1 1x UltraSPARC IIe 400MHz System clock frequency 67 MHz Memory size 64Mb CPU Units Number Frequency Cache Size Version No Hz MB Impl Mask No MHz MB Impl Mask CPU 0 400 0 2 V3 2 Used Memory Slot Number Size IO Cards Slot Name Model Bus max freq No failures found in System Initialization No Recent System Faults found For GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 opt FISVhwr sbin fjprtdiag 16 System Configuration Fujitsu PFU sun4us Fujitsu PRIMEPOWER 200 1x SPARC64 III 272MHz System clock frequency 73 MHz Memory size 64Mb CPU Units Number Frequency Cache Size Version No MHz MB Impl Mask No MHz MB Impl Mask CPU O 272 4 0 3 2 0 Used Memory Slot Number Siz
74. Disk Cabinets Expansion File Units This function is not offered to the following models PRIMEPOWER 1 This function is available in the rcinodeadm 1M command the following models offer GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER 200 400 600 Models not listed above can be operated by the Machine Administration or System console Refer to Machine Administration Guide or System Console Software User s Guide Allows the hot swapping of internal disks on Expansion Disk Cabinets Expansion File Units 2 2 Setup of Expansion Disk Cabinet Expansion File Unit An SCSI Expansion Disk Cabinet SCSI Expansion File Unit which connects RCI should be included in the system before being used However SCF does not provide commands to do this Moreover the following models are off the subject of this function PRIMEPOWER 1 As for including in the system the operation is different because of each model For the following models the RCI command that OBP OpenBoot PROM offers is used GP7000F mdel 200 200R 400 400A 400R 600 600R PRIMEPOWER 200 250 400 450 600 650 850 Refer to PRIMEPOWER USER S MANUAL or GP7000F USER S MANUAL for information on how to include the Expansion Disk Cabinet Expansion File Unit using OBP RCI commands The following models are operated by System Console GP7000F model 1000 2000 PRIMEPOWER 800 900 1000 1500 2000 2500 HPC2500 Refer to PRIMEPOWER USER S MANUAL or GP7000F
75. Displays all information A Displays active licenses f feature Displays users of feature S DAEMON Displays all users of DAEMON s features s server_name Displays the status of the specified server t timeout_value Sets a timeout interval to timeout value in seconds EXAMPLES etc opt FSUNlicense bin Imstat c cat etc opt FSUNlicense FSUN_LICENSE_FILE a The in use license file names are stored in etc opt FSUNlicense FSUN_LICENSE_FILE file See 11 4Setting of the License Password EXIT STATUS This command returns the following values 0 Ended normally Other than 0 Error Imremove 1M NAME lmremove Deletes a specified license and returns to a license pool SYNOPSYS etc opt FSUNlicense bin Imremove c lic file feature user host display DESCRIPTION lmremove deletes a specified user s license for a specified feature If the machine in which a user runs an application crashes the user license may be disabled 199 lmremove causes that this user s license can be returned to the license pool OPTIONS The following options are available c Specifies the license file name that you are using in the parameter lic file feature Specifies feature name of the license that you are deleting user Specifies the user name whose license you are deleting host Specifies the host name of the license that you are deleting display Specifies the display name of the license that you are
76. ECK LED on RCI device is turned on due to self detection of internal failures it stays lit after monitoring has restarted Note that only the super user can execute this command EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error SEE ALSO rciinfo 1M rcihello 1M 3 11 rciopecall 1M NAME rciopecall Reports operator call on units connected via RCI SYNOPSYS opt FJSVhwyr sbin rciopecall address disp on callNo off callNo AVAILABILITY FJSVscu FJSVpscu FJSVscul FJSVscu2 FJSVscu3 DESCRIPTION rciopecall reports operator call on units connected via RCI The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R 1000 2000 PRIMEPOWER 200 250 400 450 600 650 800 850 900 1000 1500 2000 2500 HPC2500 29 OPTIONS The following options are available address Specifies addresses of units connected via RCI Addresses are given in 8 digit hexadecimal You can specify the following value for action disp Displays the operator call on Sets the operator call ON off Sets the operator call OFF callNo If on or off is specified for action specifies callNo that controls the operator call callNo is given in 2 digit hexadecimal callNo is set up only in the device that 1 is specified in bit by the ON OFF designation It is possible that more than one bit is specified at the same time EXAMPLES rciopecall 000101ff on Oc xrciopecall
77. Enhanced Support Facility 2 4 1 User s Guide oO FUJITSU Preface Purpose This manual describes the Enhanced Support Facility that supports system maintenance control in a Solaris TM operating environment Hereafter Solaris OF Intended Readers This manual is intended for the following readers System administrators who introduce and operate this software Technicians who maintain system hardware Before You Begin Before you start reading this manual install the Enhanced Support Facility on your system and then make sure it is in a usable state For information on main unit hardware specifications and connections between peripherals and the main unit refer to the documentation accompanying each product Organization This manual is organized as follows System Control Facility driver is abbreviated hereafter as SCF driver System Control Facility hardware is abbreviated hereafter as SCF Part1 SCF Driver Features describes the SCF driver of GP7000F and PRIMEPOWER models It also describes the RAS Reliability Availability and Serviceability features vital for server system operation Chapter1 Main Cabinet describes the RASfeatures of the Main Cabinet Chapter2 Expansion Disk Cabinet Expansion File Unit describes the RAS features of the Expansion Disk Cabinet Expansion File Unit Chapter3 Command Reference describes the commands offered by SCF driver Chapter4 Driver Messages explains th
78. FJSV scfc scfc gt pci H FISV scfc scfc Meaning Detected SCF device failure Action Follow the instruction of the message displayed before this message WARNING FJSVscf SCF HALT was detected Meaning All SCF devices stopped After this message was displayed access to SCF device will be failed Action Follow the instruction of the message displayed before this message In addition confirm the state of the system board or the SCF device from System Console Software SCS WARNING FJSVscf SCF ready interrupt occurred Meaning SCF device was changed WARNING FJSVscf pci FISV scfc scfc SCF command 0OxXXXX timeout Meaning The SCF command 0xXXXX could not complete a command within the prescribed time Action Check the state of the system board and SCF device WARNING FJSVscf pci H FISV scfc scfc XXX register read error Meaning Recovered by re reading thought an I O register reading error occurred XXX is register name SCF 2 command SCF 2 Status SCF 2 tx data SCF 2 rx data SCF 2 control SCF 2 interrupt status Ebus 2 dma control DMA csr DMA address control DMA byte control 74 WARNING pci FISV scfc scfc offline Meaning Detected SCF device failure Action Check the state of the system board and SCF device WARNING FJSVscf scf_intr Unexpected POFF interrupt occurred Meaning A POWER switch interrupt occurred while t
79. Input power down was detected UPS is activated AAA Meaning Power is now being supplied by the UPS due to a power down of power supply unit AAA represents the power supply unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units PSU Action Check the state of the power supply of power supply unit displayed in AAA WARNING FJSVscf power supply was stopped AAA Meaning The power supplied to power supply unit AAA stopped AAA represents the power supply unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units PSU Action Check the state of the power supply of power supply unit displayed in AAA FJSVscf AC power recovered RCI addr 0xXXXXXXXX Meaning The power supply of RCI device addr 0xXXXXXXXX was restored 62 FJSVscf AC power recovered AAA Meaning The power supply to UPS connected with power supply unit AAA was restored AAA represents the power supply unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units PSU FJSVscf Input power recovered RCI addr 0xXXXXXXXX Meaning The power supply of RCI device addr 0xXXXXXXXX was restored FJSVscf Input power recovered AAA Meaning The power supply to UPS connected with power supply unit AAA was restored AAA represents the power supply
80. License Data 1 fn1 Version 2 999 2 fn2 Number of Licenses 0 3 fn3 License Password 3B5AA0F13E58142E5FFF Expiration Date 1 jan 0 Node Lock Hostid 80f12081 Please choose a feature name Cursor Key Move Cursor L Screen Redraw D Quit p Previous Page n Next Page Return Key End s Top Page e Bottom Page U UNDO The license registered in the license file is displayed in A List of Features The current contents of the feature name selected by display cursor from A List of Features are displayed in License Data Select the intended license from A List of Features the next screen will appear by pressing the return key If the required license has been deleted by mistake the screen can be reversed using UNDO but only once If it has already been reversed UNDO cannot be used again Delete an Entry lt Feature Name fnl 1 999 gt Confirm Delete it AL Screen Redraw D Quit Return Key End When the feature name is selected the confirmation screen appears Check the contents of the screen then press the return key again 11 4 8 Displaying the Contents of the License Server To display the contents registered in a license file use Display Contents of the License File When 6 Display Contents of the License File is selected on 11 4 2Top Menu the following screen appears Display Contents of the License File 1 SERVER node1 80f12081 27000 2 DAEMON J FUJI
81. PSYS usr opt FJSViomp bin iompadm p c class name status Interface Name Communication Path Name EXAMPLE Example For PRIMEPOWER 850 When p option is not specified usr opt FISViomp bin iompadm c FUSVscf3 status dev FJSVhwr fiomp mscf0 dev FISVhwr scfc0 online active block Good 35 dev FISVhwr scfcl online standby block Good Specify the communication path name usr opt FISViomp bin iompadm c FUSVscf3 status dev FJSVhwr fiomp mscf0 dev FISVhwr scfc0 dev FISVhwr scfc0 online active block Good 3 13 1 3 ident subcommand DESCRIPTION ident subcommand displays the class to which the specified communication path belongs For PRIMEPOWER 250 450 FJSVscf is displayed For GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 FJSVscf2 is displayed For PRIMEPOWER 650 850 900 1500 2500 HPC2500 FJSVscf3 is displayed SYNOPSYS usr opt FJSViomp bin iompadm ident Communication Path Name EXAMPLE Example For PRIMEPOWER 850 usr opt FISViomp bin iompadm ident dev FJSVhwr scfc0 FJSVscf3 3 13 1 4 probe subcommand DESCRIPTION probe subcommand displays the interface to which specified communication path belongs SYNOPSYS usr opt FJSViomp bin iompadm probe Communication Path Name EXAMPLE Example For PRIMEPOWER 850 usr opt FISViomp bin iompadm probe dev FJUSVhwr scfc0 FJSVscf3 dev FJSVhwr fiomp mscf0 3 13 1 5 recover subcommand DESCRIPTION recover subcommand restores the co
82. SUNWssp ssp_private var opt SUNWssp adm LMF environment setting information lmadmin r Core file information Information can be specified using coreadm Machine administration opt FJSVcsl usr opt FJSVesl lib console dat opt FJSVesl lib machine dat opt FJSVecsl lib my_console dat opt FJSVecsl lib my_segment dat opt FJSVecsl lib network dat opt FJSVesl lib pid dat System Management Console opt FJSVscsl log etc FJSVscslif etc FJSVscslentl etc FJSVscsltargets etc FJSVclowners etc FJSVeclguiusers opt FJSVscsl etc ntp conf Partition Installer opt FJSVclis tmp opt FJSVclis etc Emulex Adapter kernel dev lpfce conf kernel dev qla conf opt SMAW sbin prtcfg 10 5 1 4 Log System diagnosis information opt FJSVhwr sbin fjprtdiag v or usr platform uname i sbin prtdiag v Message log var adm messages dmesg var log syslog var log authlog var log sysidconfig log User accounting processing information var adm utmp var adm utmpx var adm wtmp var adm wtmpx uptime Volume management log var adm vold log Last login log var adm lastlog Login failure log var adm loginlog su execution log var adm sulog spell command log var adm spellhist cron log var cron log Port monitor var saf var sadm install logs var sadm install_data var sadm patch Installation ivar sadm ptf
83. SVwdl wdl_detach ddi_get_soft_state failed Meaning Could not detach the FJSVwdl driver due to the abnormal termination of ddi_get_soft_state 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVwdl wdl_ioctl ddi_get_soft_state failed Meaning Could not ioctl the FJSVwdl driver due to the abnormal termination of ddi_get_soft_state 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVwdl wdl_read ddi_get_softstate failed Meaning Could not read the FJSVwdl driver due to the abnormal termination of ddi_get_softstate 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVwdl wdl_mmap ddi_get_soft_state failed Meaning Could not mmap the FJSVwdl driver due to the abnormal termination of ddi_get_soft_state 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources 99 WARNING FJSVwdl wdl_attach ddi_regs_map_setup failed Meaning Failed to incorporate the FJSVwdl driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources WARNING FJSVwdl wdl_attach ddi_create_minor_node failed Meaning Failed to incorporate the FJSVwdl driver into th
84. TSU ete J FUJITSU 3 FEATURE fn1 J FUJITSU 1 999 1 jan 0 4 OBCAC051E7747F0220FB 4 FEATURE fn2 J FUJITSU 2 999 1 jan 0 0 83B5AAOF13E58142E5FFF 80f12081 5 FEATURE fn3 J FUJITSU 3 999 1 jan 2000 0 DB8AFOC19BDD8FA4B72E DEMO Cursor Key Move A Move Left E Move Right p Previous Page n Next Page s Top Page e Bottom Page AL Screen Redraw D Quit To exit from this screen reverse the previous screen by using the D ctrl d 11 4 9 Checking on Command Completion The setup_licensecommand checks the license registered in a license file on completion The contents shown below are checked 1 Validity of the license password 2 Valid term A license password will be checked to ensure incorrect contents are not input by the user If the license server has been registered deleted once the license password will not be recognized as the correct password Normally it is not necessary to check a license password because an unlimited license password 1 jan 0 is 190 issued But sometimes a limited license password is issued where software is only for temporary use On completion the result of the check as shown below is displayed when a failure is detected If no failure is detected no message is displayed The license file is invalid fn4 OBDAC011E677790223FD 1 jan 0 Bad Password fn5 1BDA10E173D1F8E68D6A 1 apr 99 Expired The contents are displayed in the following format Feature name License
85. USER S MANUAL and refer to System Console Software User s Guide When the Expansion File Unit without RCI is used it need not be operated to include it in the system Refer to USER S MANUAL of the Expansion File Unit 2 3 Troubleshooting SCF driver allows system notification of problems occurring in the SCSI Expansion Disk Cabinet SCSI Expansion File Unit such as power supply failures abnormal temperatures or fan failures Messages are displayed on the console in each case The system server will continue operation despite problems occurring in the Expansion Disk Cabinet Expansion File Unit as SCF driver does not in any case shut down the system server 13 When it is impossible for the Expansion Disk Cabinet Expansion File Unit to continue operation due to abnormal temperatures or other potential problems the hardware shuts off power to the Expansion Disk Cabinet Expansion File Unit after detecting the failures The Expansion Disk Cabinet Expansion File Unit should be isolated or other appropriate steps should be taken according to the messages and circumstances 14 Chapter 3 Command Reference This chapter describes the commands offered by SCF driver Refer to the following for the command offered by each model Table 3 1 The offer list of commands Models aad GP7000F eon SboRaba Model PRIMEPOWER Commands PRIMEPOWER PRIMEPOWER 1000 2000 650 850 4
86. XXX sub status 0xX9 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxYY 0x00 Meaning Detected a mount error sub status 0x09 or 0x89 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 mount error a lot of mounting 0x02 mount error few mounting 0x02 mount position is abnormal OxYY is detailed information which supplements the event code OxZZ Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please contact our customer engineer WARNING FJSVscf unexpected sense from RCI addr 0xXXXXXXXX was detected sub statu s OxYY sense info OXXX OxXX OxXX OxXX 0xZZ OxZZ 0xZZ OxZZ Meaning Detected an unexpected sense information from RCI device addr 0xXXXXXXXX sub status OxYY shows the device information command 0x4X Device status notification 0x70 Device attribute display 55 0x71 Device status display When sense information is notified according to the timing unexpected from another device connected with the RCI
87. XXXXXXXX 0xZZ shows the event code 63 0x01 Fan rotation decrease 0x02 Fan rotation stop OxYY is fan number and the number which depends on the corresponding RCI device OxNN is fan tray number and the number which depends on the corresponding RCI device 0xMM shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the fan unit of the CCC and please contact our customer engineer WARNING FJSVscf power supply unit failure on RCI addr 0xXXXXXXXX AAA sub stat us OxX2 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0xMM Meaning Detected a power supply unit failure sub status 0x02 or 0x82 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x82 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the power supply unit name represents the power supply unit number AAA will be displayed only if a power supply unit failure occurred on the following power supply units FEP SU PUDDC DC B P Cc DDC A D D DC B Sense info shows the following meanings
88. XXXXXXXX was detected sub status 0xX5 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected a power supply end of UPS sub status 0x05 or 0x85 of RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX OxZZ shows the event code 0x01 UPS became an electrical discharge end voltage 90 OxYY is UPS number and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of UPS connected with the RCI device displayed with addr UPS battery is charged or please contact our customer engineer WARNING FJSVscf UPS failure on RCI addr 0xXXXXXXXX was detected sub status Ox X5 sense info OxXX OxXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected a UPS failure sub status 0x05 or 0x85 of RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of
89. age Call a Fujitsu customer engineer 157 WARNING FJMSE 5001 ioctl mismatch Meaning Detected an internal error regarding ioctl message Action Call a Fujitsu customer engineer WARNING FJMSE 5002 Permission Denied Meaning Sent an ioctl message using user privileges other than root The iompadm command might be executed using user privileges other than root Action Execute the iompadm command using root user privileges WARNING FJMSE 5003 Invalid data size Meaning The fjmse driver received an ioctl message with inappropriate data size Action Call a Fujitsu customer engineer WARNING FJMSE 5004 Inappropriate path change Meaning Detected an internal error while the fjmse driver status changes Action Call a Fujitsu customer engineer WARNING FJMSE 5005 Invalid api_level Meaning The API level of the fjmse driver is not corresponding Action Call a Fujitsu customer engineer WARNING FJMSE 5006 Invalid instance number Meaning Detected an internal error regarding instance number Action Call a Fujitsu customer engineer WARNING FJMSE 5007 Invalid number of pathname Meaning Detected an internal error regarding the number of communication paths Action Call a Fujitsu customer engineer 158 WARNING FJMSE 5008 Inappropriate physical path name Meaning An inappropriate device name was specified as the physical device name of communication path Action Make sure that the specified devic
90. age log var adm messages as daemon error However it is not abnormal FJSVscf The system power down is executed 30 seconds later Meaning The power off of the system is begun 30 seconds later This message shows the state This message might be stored in message log var adm messages as daemon error However it is not abnormal 5 1 3 For PRIMEPOWER 250 450 pwrctrld power switch ignored Meaning The POWER switch was pressed but was ignored by the scftool 1M setting pwrctrld failed to start xxx Meaning Could not start the SCF monitoring daemon xxx represents the system call that failed Action Allocate memory or a swap area 108 pwrctrld failed to open pwrctrld pid file Meaning Could not create the PID file Action Check the capacity of the root file system and whether it is mounted in a write enabled state pwrctrid halt system Meaning System shut down due to an error pwrctrld failed to start power switch procedure xxx Meaning Pressing the POWER switch failed to initiate the shutdown procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start UPS AC down procedure xxx Meaning Failed to initiate UPS switch over procedure when power failed xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start SCFHALT procedure xxx Meaning Failed to initiate SCFHALT procedu
91. ages displayed by the SCF driver of each model and meaning of messages displayed by other drivers of this software It also describes what to do when you get error messages The system call error messages listed below are described by man s 2 Intro 4 1 SCF driver Please refer to the message of the corresponding model for SCF driver s message 4 1 1 For PRIMEPOWER 1 WARNING FJSVscf _init ddi_soft_state_init failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf _init mod_install failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install 9F incorporates the driver into the system Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough
92. ailed in access to the PICL daemon Action When the error message is Daemon not responding Check if PICL daemon is working correctly Execute the command again When the error message is not listed above Execute the command again When still becoming the error please contact the customer engineer Getting root node failed System call error message Meaning Failed in access to the PICL library Action engineer Execute the command again When still becoming the error please contact the customer 119 6 2 diskadm 1M command Usage diskadm action pathname Meaning Displayed when there is an error in the way a command option was used diskadm Not support Meaning The model not supported executed the command Action Enter a correct path name Also make sure that the SCF driver package is installed properly diskadm Only root is allowed to execute this program Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges diskadm Path name Incorrect controller Meaning A controller that does not exist was specified as a path name or could not access the SCSI Fault LED device driver Action Enter a correct path name Also make sure that the SCF driver package is installed properly diskadm Path name Incorrect controller is specified or specified controller is not supported Meaning A controller that does not exist was
93. ait monitoring timeout s unit For example etc system is specified as follows set FJSVscfiscf_rdctrl_sense_wait 2000000 3 Reboot the system 10 For GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 Set up the monitoring timeout in the etc system file as follows Calculating monitoring timeout 2 partitions 2 seconds 3 or more partitions 1 second 0 5 x number of partitions Example 1 8 partitions 2 5 seconds Example 2 4 partitions 3 0 seconds Setting up the etc system file Change the etc system file on all cluster nodes as follows 1 Copy or backup etc system using etc system org Example cp etc system etc system org 2 Add the following to etc system As the timeout is set up in s units set a value equal to the value calculated above multiplied by 1000000 set FJSVscf2 scf_rdctrl_sense_wait monitoring timeout s unit For example etc system is specified for 2 partition configuration as follows set FJSVscf2 scf_rdctrl_sense_wait 2000000 3 Reboot the system For PRIMEPOWER 650 850 Set 2 seconds for the monitoring timeout Setting up the etc system file Change the etc system file on all cluster nodes as follows 1 Copy or backup etc system using etc system org Example cp etc system etc system org 2 Add the following to etc system As the timeout is set up in s units set a value equal to the value calculated above mult
94. and the number of is not displayed AAA will be displayed only if a sensor failure occurred on the following sensors CPU SENSOR AMBIENT Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Ambient temperature low temperature warning 0x02 Ambient mperature low temperature alarm jz 0x03 Ambient temperature high temperature warning 0x04 Ambient t mperature high temperature alarm 0x05 Unit Processor low temperature warning or sensor failure 0x06 Unit Processor low temperature alarm or sensor failure 0x07 Unit Processor high temperature warning 0x08 unit processor high temperature alarm OxYY is sensor number and it depends on the corresponding RCI device OxNN shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the environment where the unit is set up Also make sure there is nothing wrong with the inside of the RCI device WARNING FJSVscf node error on RCI addr 0xXXXXXXXX sub status 0x08 sense info OxXX OxXX 0xXX OxXX 0x00 0xZZ OxYY 0xXX Meaning Detected a node error sub status 0x08 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormal
95. aning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Aborted Command Message Error Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Aborted Command SCSI parity error Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device 97 WARNING device node name FJSVsfled Aborted Command Initiator detected error message received Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Aborted Command Invalid message error Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Aborted Command Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedl
96. another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 88 OxZZ shows the event code 0x01 The internal failure of RCI I O device 0x01 05 SCF unit self diagnosis error 0x90 RCI network is abnormal status check time out 0x91 RCI address multiple error 0x92 Host node is abnormal 0x93 RCI device connection failure of unregistration 0x94 SCF degeneracy OxcO ff Hard error of RCI I O device OxYY shows detailed information of RCI network abnormality event code 0x90 or host node abnormality event code 0x92 Or when the inside abnormality of RCI I O device event code 0x00 detailed information that depends on RCI I O device is shown Other event codes are irregular values and it does not have the meaning Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check RCI address is uniquely assigned to each RCI device there are no RCI cable problems RCI device are turned power on unconfigured RCI devices are not connected or there are no internal failure in RCI devices Please contact our customer engineer panic cpuX thread OxXXXXXXXXX FJSVscf panic request from RCI addr 0xXXXXXXXX Meaning The RCI device that has RCI address of OxXXX requested the system panic Action
97. ar file system Allocate memory or a swap area Watchdog Log saved in file name Meaning The watchdog was saved savewdlog logging incomplete Meaning The watchdog log was saved but it is incomplete Action Check the var file system Allocate memory or a swap area 135 File name fopen Q failed Meaning Failed to open the file Action Check the var file system File name fcloseQ failed Meaning Failed to close the file Action Check the var file system File name fputsQ failed Meaning Write to the file failed Action Check the var file system 6 19 scfhltlog 1M command dev FJSVhwr pwrctl System call error message Meaning Access to the SCF driver failed Action Make sure that the SCF driver package is installed properly scfhltlog System call error message Meaning Failed to allocate memory Action Allocate memory or a swap area scfhltlog Removing the log in SCF failed Meaning Failed to delete the hard halt log Action Check the state of the SCF device Hard Halt Log was saved in file name The log had occurred at time Meaning The hardware halt log that had occurred at time was retrieved and stored in file name 136 scfhltlog file close failed Meaning Failed to open the file Action Check the state of the var file system scfhltlog bounds file open failed Meaning Failed to open var opt FJSVhwr wdlog bounds file Action Check the state of the
98. as daemon error However it is not abnormal FJSVscf The system power down is executed 30 seconds later Meaning The power off of the system is begun 30 seconds later This message shows the state 104 This message might be stored in message log var adm messages as daemon error However it is not abnormal 5 1 2 For GP7000F models 200 200R 400 400A 400R 600 600R and PRIMEPOWE R 200 400 600 pwrctrld Power switch is pressed Press power switch again within 5 seconds to start shutdow n procedure Meaning The POWER switch was pressed Pressing it again within five seconds starts the shutdown process pwrctrld power switch ignored Meaning The POWER switch was pressed but was ignored by the scftool 1M setting pwrctrld failed to start xxx Meaning Could not start the SCF monitoring daemon xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to open pwrctrld pid file Meaning Could not create the PID file Action Check the capacity of the root file system and whether it is mounted in a write enabled state pwrctrid halt system Meaning System shut down due to an error pwrctrld failed to start power switch procedure xxx Meaning Pressing the POWER switch failed to initiate the shutdown procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start UPS AC down procedure xxx Meaning Fai
99. ayed only if a sensor failure occurred on the following sensors CPU SENSOR Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Ambient temperature low temperature warning 0x02 Ambient mperature low temperature alarm jz 0x03 Ambient temperature high temperature warning 0x04 Ambient t mperature high temperature alarm 0x05 Unit Processor low temperature warning or sensor failure 0x06 Unit Processor low temperature alarm or sensor failure 0x07 Unit Processor high temperature warning 0x08 unit processor high temperature alarm OxYY is sensor number and it depends on the corresponding RCI device OxNN shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the environment where the unit is set up Also make sure there is nothing wrong with the inside of the RCI device WARNING FJSVscf node error on RCI addr 0xXXXXXXXX sub status 0x08 sense info OxXX OxXX OxXX OxXX 0x00 0xZZ OxYY OxYY Meaning Detected a node error sub status 0x08 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When
100. baveavenstecotdisdeuatiacdeceveusieuceecuesuenceeneaies 188 11 4 5 1 Registering Network Locked Products cccccccccesssssececececeeseenecececeeneseeaececeeeseeseeaeceeeeeeneees 188 11 4 5 2 Registering Node Locked Products ccccccsesesesesesesesesesesesesesesesesesesesesesesesesesesesesesesesenenens 188 11 4 6 Changing the License c cccccccccsessscecceeececsessssececececsesssececececeesesaseeeececseaueceeeesesenesuaseceenensaaeeeeecs 189 Itt Deleting the License sad st sivas th dete a hae ate nent ee Neale anae na a a 190 11 4 8 Displaying the Contents of the License Server cccccccccccecssssseceeececeesessececececsessssseeeeeeceesensaaeees 190 11 4 9 Checking on Command Completion ccccccccccccccessesssceeecececsenseaeceecceeesesesaececececeenesssseeeeseeesensaeees 190 11 4 10 Starting the License Daemon ceccccccesssssecssssececseeeeeeesaececseaeeeecseeeecsssaeeecseaaeeecseeesseaaeeceeaaees 191 11 4 11 Alternate Keys sc cis cceccuegedicevescecicsianeesds cateeies O nocd aden gu caves ie nde Seed Ao nies ceo 191 11 4 12 NSUNlicnz Package and FSUNIic Package ccccccccccccessesseceeececeesesececececeesenseseeeesesenenseaeeeeecs 191 11 5 Error Message List of the Client Library ec ccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseneaeeeseeeaeereeeaaaees 192 11 6 Command Reference x 2 6223 a a a a aaa aa a a aaa ai a E a Aa i aa Ena 199 11 7 Error Message List of the setup_license 2 0 0 2 ccececc
101. be booted up or shutdown by pressing the POWER Switch When the mode switch is SECURE or LOCK the POWER switch cannot be operated Switch the mode as necessary MANUAL MAINTENANCE UNLOCK should only be used when performing maintenance and related work on the system It should not be used during normal operation Turning on the system when the MODE switch is set to MANUAL MAINTENANCE UNLOCK will stop it in the OBP OpenBoot PROM state without booting up Solaris OE Normally you can enter the OpenBoot environmentwhen STOP A is entered on the console while Solaris OE is running On a tty console the Break operation is equivalent to STOP A It is possible to enter the OpenBoot environment only when the MODE switch is set to MANUAL MAINTENANCE AUTO or UNLOCK You cannot enter the OpenBoot environment when the MODE switch is set to SECURE LOCK The POWER switch only works when the MODE switch is set to MANUAL MAINTENANCE AUTO or UNLOCK It will not work when the MODE switch is set to SECURE LOCK You can display the current MODE switch setting with the command fjprtdiag v 1 2 3 2 LED lamp For PRIMEPOWER 1 There are ALARM LEDs CHECK LED and FAULT DISK LEDs Each ALARM LED will either blink or light constantly when there is a failure in the corresponding portion of the system hardware Refer to Table 1 3 ALARM LEDs below Table 1 3 ALARM LEDs ALARM LED Condition blinking or lit PWR LED Lit constantly when power
102. ble subcommand iompadm XXX Class not Found Meaning Could not find a class that corresponds to specified communication path name Action Check the specified communication path name iompadm XXX Not Supported Meaning Entered the state which is not supported by this class 156 Action Check an available subcommand iompadm XXX IO Error Meaning The command terminated abnormally Action Check the network equipment adapter cables and switches Call a Fujitsu customer engineer when there are nothing wrong with the network equipment iompadm XXX Internal Error Meaning The specified interface name does not exist or the command is not accepted Action Check the specified interface name or subcommand lompadm XXX Invalid Instance Meaning There is an error in the way the specified interface name was used Action Check the specified interface name iompadm XXX Class not Found Meaning Class name specified by XXX does not exist Action Specify a correct class name 9 2 fjmse Driver WARNING FJMSE 0002 Can t allocate system resource Meaning Failed to allocate kernel memory resource used by the fjmse driver Action Check kernel memory resource size there might not be enough kernel resources WARNING FJMSE 5000 Inappropriate ioctl for this node Meaning The fjmse driver received an inappropriate ioctl message for the specified node Action Detected an internal error regarding ioctl mess
103. ccccceeeeeeeeecneeeceeeeeeecceaeeeeeeeeeseceeaesaeeeeeeesesecciaeeeeeeneees 10 1 6 1 For SynfimityCluster ccccccccccssssssscccececssssnsaecececsesssseaaecececsensnsaaeeececsessssaaeaesecsceessaeececeensnsaaecececs 10 16 2 For PRIMECGLUSTER sess ase ccscachsses coach e E E E cvsetbascabdvish esd onde seblebset stacuonetelsvecieasevtehevs 11 Chapter 2 Expansion Disk Cabinet Expansion File Unit 0 cccceeeeeeeeeeeeeeeeees 13 2 WFeature OVCRVIGW EAO A A A AET 13 2 2 Setup of Expansion Disk Cabinet Expansion File Unit sssssssseessnenennseeeeenrrnnreneserrrrnnrenesrnt 13 2 3 THOUDIESHOOLUAG ui ES aa ARE a a ns aAA AR A A EAA ARARA S A EAA 13 Chapter 3 Command Reference cccccccccceeeeeseeeeeeeeeeeeeeaeseeeeeeeeeeeeeaeaesseeeeeeess 15 stida UM ea etcda eat cada A eon nee in en eee tesa See Me 15 32 Nsadm iM tectedeecte eden eee te attic A etic iia el sack eee eee 20 3 3 diskadm IM cectisctaceetees eee e Wee cheatin adic eerie el ata dee tin ARR 21 3 4 SCHOOI 1M E A A A E A T A E T ceed 23 3 0 SCO MCI kerrain N A T T E cavan seca sou eea ceases 24 eR eE a A E E E an E E A E E eae aia 25 SF SCIwdtimen IM asa aS AA EAR ain inti Anata AEAEE Ate 26 SB TCIMEM G T M eraa ae A E a E esac bese Atte tees Aisa sce TT 27 aroo M aceczstaieccct cee cbeedcoetesedte cece aa dh atic ctehcntetehaade ARENAN 27 3 10 reinodeadm AM cccseteicec cece cae elie set ides ees dues aa EAA NENE dues eev ined eee slanee de heee
104. ce minor node failed Action Make sure there is enough room in the device file system WARNING FJSVscf scf_attach ddi_add_intr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr 9F registers interrupt functions Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_map_regs ddi_regs_map_setup failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_map_regs ddi_dev_regsize failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_regsize 9F gets the register size 44 Action Check the state of the SCF device WARNING FJSVscf scf_chpoll ddi_get_soft_state failed Meaning poll 2 terminated abnormally due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_detach ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_open ddi_get_soft_state faile
105. cecseseuecesececseseaseeeecsesenessaseeeeseassaeeeeees 185 TT 2A Ty Pes OF LACE SE EE E tacos T cise EEEO E IEEE E ato s EAE AEI EE teed Ge EET 185 112 5 Installing a Package oo ccccicsc do veccececcecses ieee cha ceteetede tee can cetea cat R EE EE EE EE TEE 185 11 2 6 Setting Environment cccccccccccccesssssesecececsessssececececsenssaeeecececeesesaseeeeeecseesaeceeecsesenesssseesenenssaeaeeees 185 11 2 7 Registering the License Password seseseseseseseseseseseseseresererereseresereseserereoererereserereseserererereeseseres 186 VL 2 8 Startins FLEXIM ee cscs ss be vee aa he cobs Sos a ba Pee E oe Rasa ocd habe baa babel angen a Reba bavi E h 186 1123 FroubleshoownG csccn then eh teht iin alee onde E ele aids ea aa ete 186 11 4 Setting of the License Password 0000 0 ecccceeeeeeeeeeneeeeeeeeeeeeeeeeaeeeseeeaeeeseeeaeeeseeeaeeeetenaeeeeeeaaees 186 TrA Starting the setup licensen in hes estes ee Si oa phe el ea Se beak Ge OS abel abs BEE 186 11 42 Top Menule sccccc ccccsedeccecevenceeceteeceeccueactucnteecgeceacuncevddeteccucacteceteccedeckeacea davbeckeaceactudatecesceacevescdceseeactees 186 11 4 3 Registering the License Server cccccccsssecessssceceessececseceecessuececseaeeeecseeeecsesaeeecseaaeeseseeeenseeecneaaees 187 11 4 4 Deleting the License Server ccccccccccecssssssscccececssssnscecececsessnsaecececsesssscaeeeceescnsseaaeeesecensnsaaeeececs 187 17 4 5 Registering the License moe i e cated eg cuties ceucades
106. cense File 1 Add a New License Server 2 Delete a License Server 3 Add a New License Password 4 Change a License Password 5 Delete a License Password 6 Display Contents of the License File 7 Exit Please choose a menu Cursor Key Move Cursor L Screen Redraw D Quit Return Key End 186 To register added license servers and to create a new license file select 1 Add a New License Server To delete a registered license server select 2 Delete a License Server To register additional licenses select 3 Add a New License Password To update the contents registered for a license select 4 Change a License Password To delete a registered license select 5 Delete a License Password To display the contents registered for a license file select 6 Display Contents of the License File To complete the setup_license command select 7 Exit 11 4 3 Registering the License Server A user must register a license server to be able to create a new license file The license servermeans the machine which manages a license If the license server is shut down the software that uses the license manager will fail to run The server selected as the license server should be a robust and well operating server Either one or three machines can be set as the license server Setting only one machine as the license server is called Single server setting three machines is called Redundant server
107. ces WARNING FJSVscf scf_dma_alloc ddi_dma_alloc_handle failed Meaning ddi_dma_alloc_handle 9F failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_dma_alloc ddi_dma_mem_alloc failed Meaning ddi_dma_mem_alloc 9F failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_dma_alloc ddi_dma_addr_bind_handle failed Meaning ddi_dma_addr_bind_handle QF failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_dma_alloc ddi_dma_addr_bind_handle ccountp error Meaning Could not allocate continuity area to the abnormal termination of ddi_dma_addr_bind_handle QF Action Allocate memory since there might not be enough kernel resources 72 WARNING FJSVscf scf_detach ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING pci FJSV scfc scfc IOCHRDY interrupt occurred Meaning IOCHRDY timeout Ebus2 timeout interrupt occurred Action Check the state of the system board and SCF device WARNING pci FISV scfc scfc DMA host bus error Meaning Host bus error interrupt occurred to the Ebus2 DMA Action Check the state of the system board and SCF d
108. cess the power to the system is cut off without a reboot occurring 1 3 Server Setup This section describes how to set up the software to match the way the system will be operated 1 3 1 Changing PATH This software is installed on a different path than the normal Solaris OE commands you must change the PATH variable if commands etc are used If the root shell is the Bourne shell add the following line to profile If profile does not exist create a new one PATH SPATH opt FUSVhwr sbin export PATH If you are the super user by the su 1M command you will find it convenient to change the SUPATH for etc default su The following is the default SUPATH for etc default su SUPATH sets the initial shell PATH variable for root SUPATH usr sbin usr bin Set the SUPATH as follows SUPATH sets the initial shell PATH variable for root SUPATH usr sbin usr bin opt FJSVhwr sbin 1 3 2 Feature Settings This section describes the software settingsthat must be made when setting up the server or changing the system configuration However the each feature settings might be unnecessary with the using model Feature that each model can be set with is shown in Table 1 4 Feature settings list of each model Table 1 4 Feature settings list of each model Models GP7000F model GP7000F model are tai 200 200R 400 1000 2000 PRIMEPOWER WER 400A 400R 600
109. ch refer to 1 2 3 1 MODE Switch The mode switch is not mounted on PRIMEPOWER 1 Solaris OE is automatically booted by pressing the POWER switch 1 2 2 Shutdown The system shuts down when you press the POWER switchon the processing unit s operation panel When you press the POWER switch you will normally see the following message GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER _ 1 200 250 400 450 600 pwrctrld Power switch is pressed Press power switch again within 5 seconds to start shutdown procedure GP7000F model 1000 2000 PRIMEPOWER 800 1000 2000 pwrctrld Power switch is pressed Press power switch again within 30 seconds to start shutdown procedure Pressing the POWER switch again within the displayed seconds initiates the shut down process that stops the system and turns off power For the following models when the POWER switch is pressed the following messages are displayed in operation panel However nothing is displayed in the console PRIMEPOWER 650 850 900 1500 2500 HPC2500 POWER OFF OK For more information on shutting down the system using the POWER switch refer to 1 3 2 1POWER Switch Settings Note that you can also shut down the system using the shutdown 1M command 1 2 3 Using Panel Controls This section describes how to use the controls on the processing unit s operation panel 1 2 3 1 MODE Switch When PRIMEPOWER 1 is used this sec
110. ck the lithium battery of the AAA and please contact our customer engineer WARNING FJSVscf cannot report PANIC Meaning Could not notify the system panic on the other HOST when it occurred WARNING FJSVscf scf_map_regs ddi_dev_regsize failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_regsize 9F gets the register size Action Check the state of the SCF device WARNING FJSVscf scf_map_regs ddi_regs_map_setup failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources 68 WARNING FJSVscf kstat_create failed Meaning kstat_create 9F failed Action Allocate memory since there might not be enough kernel resources NOTICE FJSVscf switch status is unknown Meaning There is a problem with the panel switch setting Action Check the state of the panel switch WARNING FJSVscf kstat memory allocation error Meaning There is not enough memory Action Allocate memory since there might not be enough kernel resources FJSVscf ignoring debug enter sequence Meaning STOP A was entered while the MODE switch on the operator panel was set to LOCK FJSVscf allowing debug enter Meaning STOP A was entered WARNING FJSVscf SCF went to offline mode and was restarted Meaning SCF ente
111. cscesessecsseesssesssrseee 199 lmreread iM ccs cien ote abet tacts 200 Imstat AM avidin ceva eit CEE L99 M main cabinet MESSAQLC ccccsscccccecsesessecesceeceenerssaeeeees MODE SWitchivssccsscecs di casvecssactecieose tees av ted ove ses MODE switch and function ccccccccccceeeesseeeees 4 Multipath control command ccccceceeseeeees SL network License cseseeeeeeseeeeeeeeeeeeens 185 188 Network locked product cccccccccccceeseseseeeeees 185 node locked license cccsceeeeseeeeeeeeens 185 188 node locked product cccecececeeeeeeeceeeeeceeeeees 185 NSUNicnz package ccccccccccceceesssssceeeeeceeees 191 NSUNlicnz Package and FSUNIlic PACK a ge is socchaccocacvdsesgssthe done doseveasscesooerebeccecete 191 NER Soa npani Ala ek esheets 9 O OBP s occ sdvnsehack iad oe ae kha eins 5 OBP commands aii chutes sie Hei eee ete 28 P Panel OPEV AatiON ccccsesecesececececececeeeceeeceeeeeeeeees POWER switch ccccccccceeseenees POWER switch settings probe subcommand 0006 pritdi g acisini i enii prtdiag 1M oo prtdiag 1M o ccccccccesesesetseetsesteeeeseseseeeees R RAG ote E EEEE AE EE EE E 3 RAS features for the main cabinet 000006 3 RCI configuration table c cccccccccsessseeeeeeeenes 28 POUNDS O AO TT AET 134 PothSlloC M issiro naa At 27 YCNO ae e T a NA 132 PCLINFO LM cceceescese
112. ction Make sure that the SCF driver package is installed properly hsadm power_unit kstat_lookup failed System call error message Meaning Could not read power supply state Action Make sure that the SCF driver package is installed properly hsadm kstat_read failed System call error message Meaning kstat_read 3K failed Action Make sure that the SCF driver package is installed properly 6 4 scfdate 1M command 126 usage scfdate sync Meaning Displayed when there is an error in the way a command option was used scfdate not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges dev FJSVhwr pwrctl System call error message Meaning Failed to open the SCF driver Action Make sure that the SCF driver package is installed properly 6 5 scfconf 1M command Usage scfconf p 1 2 offt e scf tod u time Meaning Displayed when there is an error in the way a command option was used It is displayed for GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 1 100 200 400 600 Usage scfconf p 1 2 offt e scf tod bu time br on off t on off Meaning Displayed when there is an error in the way a command option was used It is displayed for GP7000 F model 1000 2000 and PRIMEPOWER 800 1000 2000 scfconf not super user Meaning The command was executed using user privileges other than root Act
113. ctrld halt system Meaning System shut down due to an error pwrctrld failed to start power switch procedure xxx Meaning Pressing the POWER switch failed to initiate the shutdown procedure xxx represents the system call that failed 103 Action Allocate memory or a swap area pwrctrld failed to start Power Supply Unit failure procedure xxx Meaning Failed to initiate power supply failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start FAN failure procedure xxx Meaning Failed to initiate fan failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start thermal alarm procedure xxx Meaning Failed to initiate abnormal temperature procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start SCFHALT procedure xxx Meaning Failed to initiate SCFHALT procedure xx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Off procedure xxx Meaning Failed to initiate Power Off procedure xxx represents the system call that failed Action Allocate memory or a swap area etc rc0 d KOOFJSVscf scfreport shutdown was executed Meaning Reported the start of system shutdown to SCF device This message might be stored in message log var adm messages
114. d Meaning Could not open the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_close ddi_get_soft_state failed Meaning Could not close the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_read ddi_get_soft_state failed Meaning Could not read the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_ioctl ddi_get_soft_state failed Meaning SCF driver ioctl failed due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources 45 WARNING FJSVscf scf_rfantest redundant fan test failed Meaning Failed to start the redundant fan test that is performed periodically within the SCF driver Action Check the state of the SCF device NOTICE FJSVscf cannot set watchdog SCF busy Meaning Failed to issue the CPU monitoring command to the SCF device Action Check the state of the SCF device FJSVscf ignoring debug enter sequence Meaning STOP A was entered while the MODE switch on the operat
115. d SCF device WARNING FJSVscf scf_intr Unexpected POFF interrupt occurred Meaning A POWER switch interrupt occurred while the mode switch on the operator panel was set to LOCK Action Check the state of the mode switch WARNING FJSVscf AC power down was detected UPS is activated RCI addr 0xXXXXXXX X Meaning Power is now being supplied by the UPS due to a power down Action Check the state of the power supply 85 FJSVscf AC power recovered RCI addr 0xXXXXXXXX Meaning Power was restored on the RCI device 0xXXX WARNING FJSVscf fan unit failure on RCI addr 0xXXXXXXXX AAA BBB CCC sub status 0xX1 sense info OXXX OxXX OxXX 0xXX OxXX OxZZ OxYY OxNN 0xMM 0xMM Meaning Detected a fan unit failure sub status 0x01 or 0x81 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x81 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the cabinet type represents the cabinet number AAA will be displayed only if a cabinet type failure occurred on the following cabinet type Cabinet 0 Main Cabinet Cabinet l Expansion Cabinet Rack I O Rack P Cabinet Power Cabinet BBB represents the unit
116. d it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the environment where the unit is set up Also make sure there is nothing wrong with the inside of the RCI device WARNING FJSVscf node error on RCI addr 0xXXXXXXXX sub status 0x08 sense info OxXX OxXX OxXX OxXX 0x00 0xZZ OxYY 0x00 Meaning Detected a node error sub status 0x08 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 The internal failure of RCI I 0O device 0x01 05 SCF unit self diagnosis error 0x90 RCI network is abnormal status check time out 0x91 RCI address multiple error 0x92 Host node is abnormal 0x93 RCI device connection failure of unregistration 0x94 SCF degeneracy OxcO ff Hard error of RCI I O device OxYY shows detailed information of RCI network abnormality event code 0x90 or host node abnormality event code 0x92 Or when the inside abnormality of RCI I O device event code 0x00 detailed information that depends o
117. ddr 0xXXXXXXXX Meaning The RCI device that has RCI address of 0xXXX requested the system panic Action This message shows the state However at the cluster environment etc another node RCI address 0xXXXXXXXX which detected abnormality issues the panic instruction to this node via RCI And when OS panic is executed this node outputs this message Please investigate this node from information on another node RCI address OxXXXXXXXX NOTICE FJSVscf I O node status sense from RCI addr 0xXXXXXXXX sub status 0x62 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxYY 0xMM 0x00 Meaning Detected a sensed information of I O node status sub status 0x062 from RCI device addr OxXXXXXXXxX This message displays the change of the state of this system or another device connected on the RCI network Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX When the RCI address is this system details of sense info become as follows OxZZ shows the event code 0x01 add 0x02 delete OxYY shows unit type and OxMM shows unit number 0x02 FAN 0x03 PSU When the RCI address is another device details of sense info become as follows OxZZ shows the event code 0x01 RCI I O device connection or power supply reentry 0x02 RCI I O device disconnect OxYY is type or number of RCI I O device and it depends on corresponding RCI I O device Action It
118. default O etc passwd definit User group definition leteigroup System dump output destination definition etc init d sysetup minfree file under Savecore directory or var crash uname n Message related etc syslog conf Port monitor definition etc saf Power management autoshutdown etc power conf at activation definition var spool cron atjobs cron information var spool cron crontabs AUDIT related etc security audit Network ifconfig a etc inet etc netconfig etc resolv conf etc rpe etc defaultdomain etc defaultrouter etc ethers etc hostname etc named boot UUCP etc uucp Remote execution etc hosts equiv Mail related etc mail ls l usr lib sendmail SNMP definition etc snmp var nis NIS NIS etc nsswitch conf varlyp ls l var yp binding autofs definition etc auto_master etc auto_home Dial calling passwd etc d_passwd etc dialups FLEX m File can be specified using etc opt FSUNlicense FSU_LICENSE_FILE Option etc opt Web Based Admin View environment definition etc opt FJSVwvbs etc webview cnf WWW Server for Admin View environment definition etc opt FJSVwvenf etc W EBCNF conf Crash Dump Assistant etc opt FJSVdmp fjdmpadm conf System Service Processor SSP UE10000 etc ssphostname 173 var opt
119. deleting EXAMPLES etc opt FSUNlicense bin Imremove c cat etc opt FSUNlicense FSUN_LICENSE_FILE feature username hostname ttyname The in use license file names are stored in etc opt FSUNlicense FSUN_LICENSE_FILE file See 11 4Setting of the License Password The feature name user name host name and display name must be obtained by the output of Imstat a EXIT STATUS This command returns the following values 0 Ended normally Other than 0 Error Imreread 1M NAME lmreread Signals to the license daemon for rereading the license file SYNOPSYS etc opt FSUNlicense bin Imreread c lic file DESCRIPTION lmreread controls the license daemon that rereads the license file If the contents in the license file are changed it will be read by Imreread In that case it is not necessary to restart the license daemon Note that Imreread cannot be used to change server node names or port numbers The license daemon must be stopped and restarted OPTIONS The following options are available c Specifies the license file name that you are using in the parameter lic file EXAMPLES etc opt FSUNlicense bin Imreread c cat etc opt FSUNlicense FSUN_LICENSE_FILE The in use license file names are stored in etc opt FSUNlicense FSUN_LICENSE_FILE file See 11 4Setting of the License Password EXIT STATUS This command returns the following values 200 0 Ended normally Other than 0 Err
120. driver Action Allocate memory since there might not be enough kernel resources WARNING pci FISV scfc scfc scf_probe ddi_dev_nregs failed Meaning The register information in the SCF device is incorrect Action Check the state of the system board WARNING FJSVscf scf_attach ddi_get_iblock_cookie failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_iblock_cookie 9F allocates resources for interrupt processing Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_create_minor_node failed Meaning Failed to incorporate the SCF driver into the system because the creation of the device minor node failed Action Make sure there is enough room in the device file system WARNING FJSVscf scf_attach kmem_zalloc failed Meani
121. driver into the system due to the abnormal termination of ddi_get_iblock_cookie 9F allocates resources for interrupt processing Action Allocate memory since there might not be enough kernel resources WARNING FJS8Vscf scf_attach ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources 71 WARNING FJSVscf scf_attach ddi_create_minor_node failed Meaning Failed to incorporate the SCF driver into the system because the creation of the device minor node failed Action Make sure there is enough room in the device file system WARNING FJSVscf scf_attach kmem_zalloc failed Meaning kmem_zalloc 9F failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_add_intr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr 9F registers interrupt functions Action Allocate memory since there might not be enough kernel resour
122. e No MB No MB No MB No MB SLOTO 32 SLOT1 32 IO Cards Slot Name Model Bus max freq PCI 6 scsi glm Symbios 53C875 PCIBUS D 33Mhz No failures found in System Initialization No Recent System Faults found For PRIMEPOWER 250 450 opt FISVhwr sbin fjprtdiag v 6 System Configuration Fujitsu sun4us Fujitsu PRIMEPOWER250 2x SPARC64 IV System clock frequency 220 MHz Memory size 64Mb Memory size 1024Mb CPU Units Number Frequency Cache Size Version No MHz MB Impl Mask No MHz MB Impl Mask CPU 0 675 4 0 4 0 7 CPU 1 675 4 0 4 0 7 Used Memory Slot Number Size No MB No MB No MB No MB SLOT 0 256 SLOT 1 256 SLOT 2 256 SLOT 3 256 IO Cards Slot Name Model max freq PCI 00 scsi glm Symbios 53C875 33Mhz PCI 01 SUNW hme pcil08e 1001 SUNW qsi cheerio 33Mhz No failures found in System Initialization 17 No Recent System Faults found Environmental Status MODE switch position is in MAINTE mode System Temperatur Cys AMBIENT 25 System PROM revisions RST 1 1 4 2002 10 18 15 12 POST 1 1 3 2002 10 15 14 03 For GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 opt FISVhwr sbin fjprtdiag v System Configuration Fujitsu PFU sun4us Fujitsu Siemens GP7000F 2000 2 slot 5x SPARC64 III 300MHz System clock frequency 100 MHz Memory size 4096Mb CPU Units Number Frequency Cache Size Version
123. e Make sure that the SCF driver package is installed properly ioctl System call error message Meaning ioctl of the SCF driver failed Action Make sure that the SCF driver package is installed properly 6 15 rciinfo 1M command rciinfo failed to open dev FJSVhwr rcictl rciinfo failed to open dev FJSVhwr rcictl2 Meaning Failed to open the SCF driver 132 Action Make sure that the SCF driver package is installed properly rciinfo ioctlQ failed Meaning Could not access the SCF driver Action Check the state of the SCF device rciinfo mallocQ failed Meaning Could not allocate memory Action Allocate memory or a swap area 6 16 rcinodeadm 1M command usage rcinodeadm address enable disable Meaning Displayed when there is an error in the way a command option was used rcinodeadm failed to open dev FJSVhwr rcictl Meaning Failed to open SCF driver Action Make sure that the SCF driver package is installed properly rcinodeadm invalid rci address Meaning Invalid RCI address was specified Action Enter a correct RCI address rcinodeadm ioctl0 failed Meaning Could not access the SCF driver Action Check the state of the SCF device rcinodeadm RCI xxx does not exist Meaning The RCI device that address has specified RCI address XXX does not exist 133 Action Enter a correct RCI address 6 17 rcihellodM command usage rcihello on off address Mea
124. e Oct 27 11 57 00 JST 1998 NOTES If you use scftool 1M or scfconf 1M to operate the system with the setting for using the SCF high resolution clock and you change system time with commands such as date 1 you must synchronize the time of the SCF high resolution clock Note that only the super user can execute the sync option of this command When the system is started in the single user mode and system clock is changed after opt directory is mounted by using maount 1M and mountall 1M this command can be executed EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error 3 7 scfwdtimer 1M NAME scfwdtimer Controls the watchdog timer function SYNOPSYS opt FJSVhwr sbin scfwdtimer enable disable AVAILABILITY FJSVlscu DESCRIPTION scfwdtimer controls watchdog timer function of System Monitor The following models can use this command PRIMEPOWER 1 If you specify enable the watchdog timer function will be effective It allows rebooting a system automatically when a system is not responding over 14 minutes This is equivalent to pressing a reset switch At this point all the programs running on the system are stopped forcibly and data held only in the memory is destroyed If you specify disable the watchdog timer function will stop without monitoring the system This function is disabled every time you start the system If you use this function specify enable each time you
125. e automatically at the time of hardware failure detection of the serial port for consoles under OS operation and operation of OS console is continued DR Dynamic Reconfiguration function is supported The system board with the broken serial port can be replaced while the system is running By using with the system console software the function to monitor the communicating state of the connected equipment from a RS 232C cable to the System Management Console and to switch a console path automatically when unusual is supported The kind of monitoring function of the duplicated console path supported by the combination of ESF and SCS is as follows Table 16 1 Kind of monitoring function ESF SCSL 6 SCS 1 7 or later 1 7 1 1 1 1 8 1 1 2 0 or later 1 2 1 monitors only main path 2 monitors main and standby paths Please refer to a System Console Software User s Guide about the details of system console software 145 7 2 Configuration At the first setup of the partition serial ports on the system boards installed in the smallest slot number and the second of smallest slot number are automatically selected for the console from among the system boards which comprise the partition by OpenBootPROM OBP And OBP saves the information of selected system boards to the OBP s environment variables tty conspath and tty sub conspath Even if the composition of the system board in a partition
126. e for IOMP device info Returns information about an instance probe Returns class and instance name for IOMP device recover Recovers the path after an error start Restarts the use of a path status Returns the path status version Shows versions usage iompadm c fjmse active instance name device nam iompadm c fjmse help iompadm ident device nam iompadm p c fjmse info instance name iompadm probe device name iompadm c fjmse recover instance name device name iompadm c fjmse start instance name device name iompadm p c fjmse status instance name device name iompadm c fjmse version 154 Chapter 9 Messages This chapter gives the meaning of messages displayed about the Serial Port IOMP feature It also describes what to do when you get error messages 9 1 iompadm Command iompadm cannot initilize library Permission Denied Meaning The initialization failed because the command was executed using user privileges other than root Action Execute the command using root user privileges iompadm cannot initilize library No Memory Meaning The initialization failed due to insufficient memory Action Allocate memory and execute the command again iompadm Too many classes specified Invalid Arguments Meaning A class was specified more than once Action Check the format of the command iompadm invalid command Invalid Arguments Meaning There is an error in the way a subc
127. e is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled No Sense Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Illegal Request Invalid command operation code Meaning SCSI command error occurred on Fault LED device described as device node name 96 Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Illegal Request Logical unit not supported Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Illegal Request Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Unit Attention Power on reset or bus device reset occurred Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device WARNING device node name FJSVsfled Unit Attention Me
128. e meanings of messages displayed by the SCF and other drivers It also describes what to do when you get error messages Chapter5 Messages explains the meanings of messages displayed by the SCF Monitoring daemon of each model It also describes what to do when you get error messages Chapter6 Command Messages explains the meanings of messages displayed by command that SCF driver offers It also describes what to do when you get error messages Part2 Serial Port Driver Features PRIMEPOWER800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models 1000 2000 describes console connection via the onboard serial port of PRIMEPOWER800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models 1000 2000 Chapter7 Connecting the Console describes the connection of console via onboard serial port Chapter8 Command Reference describes the commands offered by this software Chapter9 Messages gives the meanings of messages displayed about the Serial Port IOMP feature It also describes what to do when you get error messages Part3 Maintenance Facility describes the System Data Output Tool Chapter10 System Data Output Tool describes the System Data Output Tool Part4 Common Base Facility describes the Common Base Facility Chapter11 License Manager describes FLEXIm License manager that works with Solaris OE Chapter12 Server Default Configuration describes the Log Clear function Notations Used The following shows th
129. e name is correct Call a Fujitsu customer engineer when there is nothing wrong in the specified device name WARNING FJMSE 5010 Invalid number of instance Meaning Detected an internal error regarding the number of instance Action Call a Fujitsu customer engineer WARNING FJMSE 5011 Inappropriate Instance Control Node Name Meaning Detected an internal error regarding name of instance control node Action Call a Fujitsu customer engineer NOTICE FJMSE 5012 Path Status is not Unconfigured empty Meaning Failed to add a communication path because the communication path has been already added to the IOMP constitution Action Use the iompadm command to check the state of communication path Call a Fujitsu customer engineer when there is no state of communication path WARNING FJMSE 5013 Lower path info table does not exist Meaning Detected an internal error regarding control information of communication paths Action Call a Fujitsu customer engineer WARNING FJMSE 5014 All of path can not be status Offline stop Meaning Failed to stop communication paths because all communication paths were going to be changed to stop status Action Call a Fujitsu customer engineer WARNING FJMSE 5016 Another process uses this device Meaning Could not handle a communication path with the fjmse driver since other process was used 159 Action Execute the iompadm command again after another iompadm command was complet
130. e notation conventions used in this manual The titles of chapters are enclosed in parentheses Example See Chapter1 Main Cabinet Commands and other input use the following prompts C shell prompt prompt Bourne and korn shell prompt prompt Super user prompt Key combinations are represented for example by STOP A which means to simultaneously press the STOP and A key Reference Manuals If necessary refer to the following manuals Hardware documentation External Disk Cabinet Units User s Manual Software Install Guide Manual of each product Trademarks Solaris TM Operating Environment Hereafter Solaris OE Solaris TM 2 6 Operating Environment Hereafter Solaris 2 6 OE Solaris TM 7 Operating Environment Hereafter Solaris 7 OE Solaris TM 8 Operating Environment Hereafter Solaris 8 OE Solaris TM 9 Operating Environment Hereafter Solaris 9 OE OpenWindows and SunVTS are trademarks or registered trademarks of Sun Microsystems Inc hereafter referred to as Sun Microsystems in the U S and other countries Solaris is a trademark or registered trademark of Sun Microsystems All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products with the SPARC trademark are based on architecture developed by Sun Microsystems Motif is a trademark of Open Software Foundation Inc FLEXIm is a registered t
131. e same as addr OxXXXXXXXX OxZZ shows the event code 0x01 RCI I O device connection or power supply reentry 0x02 RCI I O device disconnect OxYY is type or number of RCI I O device and it depends on corresponding RCI I O device Action It is not necessary When this message is frequently displayed it is necessary to investigate the RCI device and please contact our customer engineer WARNING FJSVscf device sense from RCI addr 0xXXXXXXXX sub status OxYY sense info OXXX OxXX OxXX OxXX 0xXZZ OxZZ 0xZZ OxZZ Meaning Detected a sensed information form RCI device addr 0xXXXXXXXX that SCF driver does not support or undefined This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI OxYY shows the event code notified the SCF driver Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows notified sense information and is an irregular value Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please contact our customer engineer When RCI device is this system check whether to operate about Machine Administration WARNING FJSVscf UPS low battery
132. e system because the creation of the device minor node failed Action Allocate memory since there might not be enough kernel resources 4 5 Flash Update Driver WARNING FJSVfupd _init ddi_soft_state_init failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd _init mod_install failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of mod_install 9F Gncorporates the driver into the system Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_probe ddi_get_soft_state_zalloc failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_probe ddi_dev_regsize failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F acquisition of register size Action Allocate memory since there might not be enough kernel resources 100 WARNING FJSVfupd fupd_probe ddi_get_soft_state failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination
133. e the license file name defined in etc opt NSUNlicnz NSUN_LICENSE_FILE file to the license file name defined in etc opt FSUNlicense FSUN_LICENSE_FILE file 191 11 5 Error Message List of the Client Library This section describes the error codes and the error message list displayed by FLEXI m client library in the application Cannot find license file Error code 1 Meaning A license file cannot be opened Action Create a license file If a license file has already been created place it in a specified place Invalid license file syntax Error code 2 Meaning The license file contains an invalid record Action Check the contents in the license file Determine whether The server name is longer than 32 characters A FEATURE line contains no hostid or 0 as the number of licenses A node locked product has not been set 0 as the number of licenses Cannot connect to a license server Error code 3 Meaning The DAEMON line contains an invalid specification Action Correct the DAEMON line License number of users already reached Error code 4 Meaning The number of users has already reached the maximum permitted number of licensees Action End any unnecessary application processes to keep the number of users below the maximum allowable number of licensees Or issue the Imremove command to override the license limit No such feature exists Error code 5 Meaning A specified feature is not found in the license f
134. eaning ioctl 2 to the SCSI Fault LED device driver failed 123 Action Check the state of SCSI Fault LED device diskadm dev FJSVhwr sfledX open failed Device Busy Meaning Another diskadm command is being executed Action Execute the command again diskadm dev es sesX open failed Device Busy Meaning Another diskadm command is being executed or failed to open the SES device driver Action Execute the command again diskadm dev openprom open Q failed System call error message Meaning Failed to open dev openprom Action Check the dev openprom file diskadm ioctl0 OPROMNXTPROP failed System call error message Meaning ioctl 2 to the dev openprom failed Action Check the dev openprom file diskadm ioctl OPROMGETPROP failed System call error message Meaning ioctl 2 to the dev openprom failed Action Check the dev openprom file diskadm ioctl OPROMNEXT failed System call error message Meaning ioctl 2 to the dev openprom failed Action Check the dev openprom file diskadm ioctl OPROMCHILD failed System call error message Meaning ioctl 2 to the dev openprom failed 124 Action Check the dev openprom file diskadm ioctlQ SESIOC_GETNOBJ failed System call error message Meaning ioctl 2 to the SES device driver failed Action Check the dev es sesX file diskadm ioctlQ SESIOC_LSETNOBJ failed System call error message Meanin
135. eccecceceeeeeeeeeeceeeeeeeseceneaeeeeeeeeeeeessnnaeeeeees 201 TETAI Atis tup litense startup necra edi Ea EEN da ieee ae etek asa cs ae OO Red AE 201 vi 11 7 2 During the Setup_license execution 11 7 3 At setup_license completion Chapter 12 Server Default Configuration 12 1 Feature Overview 12 2 Target log file list 12 3 Details of log files vii vill Part 1 SCF Driver Features Part1 SCF Driver Features describes the SCF of GP7000F and PRIMEPOWER and the RAS Reliability Availability and Serviceability features vital for server system operation SCF driver of PRIMEPOWER 1 controls System Monitor Chapter 1 Main Cabinet This chapter describes the RASfeatures of the Main Cabinet 1 1 Feature Overview This section provides an overview of the features offered in the main cabinet 1 1 1 Hardware SCF However System Monitor in case of PRIMEPOWER 1 is offered to the main cabinet hardware of GP7000F PRIMEPOWER as standard SCF provides features for monitoring hardware status and notifying software when failures occur 1 1 2 Software SCF driver controls the hardware SCF and provides the following RAS Reliability Availability and Serviceability features vital for server system operation Automatically shuts down the system to prevent damage when fan failures abnormal temperatures or other potentially destructive malfunctions occur When redundant power supplies and fan units are possible for system
136. ecessary to check the abnormality of the RCI device displayed with addr Check the power supply unit of the AAA and please contact our customer engineer WARNING FJSVscf thermal alarm on RCI addr 0xXXXXXXXX CPU sub status 0xX6 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected an abnormal temperature sub status 0x06 or 0x86 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x86 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI CPU represents the CPU sensor number or sensor number Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX OxZZ shows the event code 0x01 Ambient temperature low temperature warning 0x02 Ambient mperature low temperature alarm 0x03 Ambient temperature high temperature warning G 0x04 Ambient mperature high temperature alarm 0x05 Unit Processor low temperature warning or sensor failure 0x06 Unit Processor low temperature alarm or sensor failure 0x07 Unit Processor high temperature warning 0x08 unit processor high temperature alarm 76 OxYY is sensor number an
137. ed since the iompadm might be executed in other process Call a Fujitsu customer engineer when there is nothing wrong in the process WARNING FJMSE 5017 Upper path info table does not exist Meaning Detected an internal error regarding control information of communication paths Action Call a Fujitsu customer engineer WARNING FJMSE 5018 Path status is not Offline stop fail Meaning Detected an internal error with the state other than stop or fail Action Use the iompadm command to check the state of communication path Call a Fujitsu customer engineer when there is the state stop or fail WARNING FJMSE 5020 Upper path info table already exist Meaning Constituted again the communication path which has been already constituted to IOMP constitution Action Call a Fujitsu customer engineer WARNING FJMSE 5021 Could not find Lower Path Info table for dev fjse X Meaning The communication path dev fjse X which is going to be constituted to IOMP constitution does not exist Action Call a Fujitsu customer engineer WARNING FJMSE 5022 Inappropriate ioctl for this path status Meaning The fjmse driver received an ioctl message which does not correspond to the state of communication path Action Call a Fujitsu customer engineer WARNING FJMSE 5024 Inappropriate correspondence between upper path info and lower path info table Meaning Detected an internal error regarding control information of communicati
138. ed_attach0 failed Meaning attach failed Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled fled_getinfo failed Meaning getinfo failed Action Allocate memory since there might not be enough kernel resources NOTICE FJSVfled kmem_zallocQ failed Meaning kmem_zalloc 9F failed Action Allocate memory since there might not be enough kernel resources 93 NOTICE FJSVfled fled_read_propQ failed Meaning Failed to read property led control 0 or led control 1 Action Allocate memory since there might not be enough kernel resources WARNING FJSVfled ddi_dev_is_sidQ failed Meaning ddi_dsv_is_sid 9F failed during probe Action Allocate memory since there might not be enough kernel resources 4 3 SCSI Fault LED Driver WARNING FJSVsfled _init ddi_soft_state_init failed Meaning Failed to incorporate SCSI Fault LED driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled _init mod_install failed Meaning Failed to incorporate SCSI Fault LED driver into the system due to the abnormal termination of mod_install 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled _fini mod_remove failed Meaning Failed to remove SCSI Fault LED driver from the system due to the abnormal termination of mod_remo
139. eee L67 FISVwal Driverinn nahinon iiia 98 FLEXIT nairean e 185 FLEXI m package cc ceceeseceeceeeeeeestttteeeeeeee 185 FLEXI m licensed application ccccccceeeeeee 185 FSUNNi rennan oie beelainin iden 185 FSUNIic package cccccccccccceesssseceeeeesestseeeeeeee L91 G GUI controlling SCF features 0 cc cesses 23 H l ident SUDCOMMANA ee eccecececeeeeeeeeeeeeees 36 152 info SUDCOMMAA ccccccceeeestsseceeeeeesettstseeeeeee 150 info SUbBCOMMANA c ccccccceeesssseeeeececsenteseeeeees 33 IOMP 50sec cise sends ee PSN ab see eed vest te 146 TOM PAIN eeno ninen aa cence 140 155 iompadm SubcOMMANA ccseseseseseseteseteteteeee 333 TOMpadM 1M eneston EEA 31 149 L LCD Patel cccceccesssssccececsessnsccccececeessneaecececeenes 6 WOME cee cececececececccecececececececececeseeeeeseeeseseeeeeeeeee 131 license ChECK acrana na a L90 license daemon sesesesesesesesesereresererererererererese L91 license Manager eecececccececeeecececeeeeeeeeeeeeeeeeeeeee L85 license monitoring daemon cceeeseeeeeeeeeeee L99 license password setting ccccccceeesetteeeeeee 186 license poluir ek hohe deh ames 199 license Servet ceeeeeseeeseseseseeecececeseceseeeseeeseeeeeeee L87 license Server MACHINE s sssesssssesssssssssseseseseseeee 185 license type woereseecccecscscseseseeesececeseseeeseseseeeseseeeeee L85 Imremove 1M eeceeeceees
140. eeeenaeceees 113 Chapter 6 Command Messages icicc cccccc dedecccecedeseie cebeecedcedeoeie chbedeiecebedececebeoncecebers 117 GA fpidag IN command sorisa celtic Ate see Aladin aA EAA A e Ee 117 6 2 diskadim TM COMMANA EEEE 120 3 hsadm IMI COMMA serier o taba E EN AE EA R E TAE 125 6 4 scidate 1M command esisiini iiia nadie noe EE ENNA E Ea iai 126 6 5 sciconf 1M command ienien aaaeeeaei ina en chee ee ie 127 6 6 setodi IN commander A A AA AAA A T A 128 6 7 sci2ted 1M command nesai a a en i r a e 128 6 8 srambackup 1M command sne tenisinin e e a e 128 6 9 scferrlog 1M commando ana n E A E ead 129 6 10 scfpwrlog 1M Command erea aa E E E E S 130 6 11 scfreport 1M command ie iosrsiiiripiiirisiu reiri ioi iee nieee i eied 131 6 12 Icdecho 1M tomman d irea E E E E A EAR A AEE AE AE EA 131 6 13 scfwatchdog 1M COMMANG eese arnan Erann Een EATARRA E EKRENE ARRI FEAN ERAR E EAER R IAO ER N TERRE 131 6 14 aeeai ala EE P E E E E E E E E S T E E 132 6 15 relinfo 1M COMUIMANG eea ae REER EE K AA EERTE AAEE E A EAA 132 6 16 rcinodeadm 1M COMMANA iaeiaiai inanan nE AEE NAAA AEEA RRE aia aa EA RRASA 133 6 17 reihello T Command a E ANA ENE sends AA 134 6 18 savewdlog 1M COMMANG espeia eaaa A E EE AA teed 134 6 19 s fhilog 1M COmmMmaAnd neser oii ia anasi iina eA AAEE AEEA AEE NAAA 136 6 20 scfnotice 1M COmMmman reiri aneian aieiai anaia iaaa A AAAA AA EENAA ENAA 137 6 21 rciopecall 1M command oer aA a E A R 138 6 22 nodeled 1 M co
141. en dev openprom System call error message Meaning Failed to open dev openprom Action Check the dev openprom file fjprtdiag close error on dev openprom System call error message Meaning Failed to close dev openprom Action Check the dev openprom file Prom node has no properties Meaning Found a OBP device node that does not have any properties Action Check the OBP device node fjprtdiag openeepr device open failed System call error message Meaning Failed to open dev openprom Action Check the dev openprom file fjprtdiag dev openprom open failed System call error message Meaning Failed to open dev openprom Action Check the dev openprom file 118 System architecture does not support this option of this command Meaning The system does not support this command Action Run the command on a system that supports it open of devices failed System call error message Meaning Failed to open devices Action Check the devices directory and the files under it ffb data malloc failed System call error message Meaning Could not allocate a data area for storing FFB information Action Allocate memory or a swap area No PCI bus in this system Meaning The system that runs the command does not have PCI bus Action fjprtdiag is a command that is platform dependent Run a command suitable for the platform picl_initialize failed System call error message Meaning F
142. es due to a full command buffer on the SCF device But they were not processed normally 0x represents the command code that ended in an error Action Check the state of SCF device WARNING FJSVscf scf_map_regs ddi_dev_regsize failed Ebus T O register Meaning ddi_dev_regsize 9F gets register size terminated abnormally Action Check to make sure that nothing is wrong with the hardware Ebus WARNING FJSVscf scf_map_regs ddi_regs_map_setup failed Ebus T O register Meaning ddi_regs_map_setup 9F maps register terminated abnormally 50 Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_icotl Status Check Timeout Control command timeout Meaning The Status Check Timeout Control command of the SCF could not complete within the prescribed time Action Check the state of the SCF device WARNING FJSVscf EBus TimeOut EBus T O Status register Ox Meaning A Ebus timeout occurred represents the value in the Ebus Timeout Status register Action Check to make sure that nothing is wrong with the hardware Ebus WARNING FJSVscf scf_intr cannot get p off factor Meaning Could not get the power on off factor from the SCF Action Check the state of the SCF device panicl cpuX thread 0xXXXXXXXX FJSVscf panic request from RCI 0xXXXXXXXX Meaning The RCI device that has RCI address of requested the system panic Action This message shows the state
143. esfinfo data opt FJSVbse etc install log opt FJSVbse etc remove log opt FJSVbse etc ver_comp log opt FJSVbse etc order data Web Based Admin View etc opt FJSVwvbs etc bin wvCntl glogs all modification information of Fujitsu middleware var opt FJMWupdate showup sh var opt FJMWupdate showup sh p 175 WebSysAdmin opt SMAW bin getwsalog 10 5 1 5 Operation Status Process list ps rect ptree Inter process communication status ipcs a Processor management information psrinfo v SWAP swap l swap s SCF dump var opt FJSVmadm scfdump Crash dump ls l Savecore directory or ls l var crash uname n System activity var adm sa File system mounting etc mnttab Mrs SS NIS ypwhich m RPC management information ae an FLEXI m lmstat a MTL library device status lmdisplay RC2000 Information is output by regetinfo RC2000 Java etc opt FJSVrcon bin regetinfo2 u Dynamic Reconfiguration Dynamic Reconfiguration information files Parallelnavi opt FJSVpnrm bin pnavisnap SRFS over BLASTBAND HPC opt FJSVsrfs bin srfssnap BLASTBAND HPC opt FJSVbbdts bin bbsnap 10 5 2 Printer Related The printer related collected datais shown below Log information of lp command activation var p logs Alert information var mail lp Printing copied to spool area data and error option var
144. ev FISVhwr scfc0 online active block Good 33 gt devices pci 83 4000 ebus 1 FISV scfc 14 200000 scfc0 dev FISVhwr scfcl online standby block Good gt devices pci 8f 4000 ebus 1 FISV scfc 14 200000 scfcl Node dev FISVhwr pwretl dev FISVhwr pwretl2 dev FJSVhwr rcictl dev FJISVhwr rcictl2 dev FISVhwr rasctl dev FJSVhwr rasctl2 Function MPmode false AutoPath true Block true NeedSync false Table 3 2 Communication path status explains information output in the above examples Table 3 2 Communication path status Information Description Indicates the status of the communication path online offline online enabled to communicate offline disabled to communicate Indicates the detailed status of the communication path active enabled to communicate or being communicated standby ready for communication active standby stop fail disconnected but in an idle state stop stopped state fail disabled to communicate caused by a failure disconnected detached communication path by Dynamic Reconfiguration Indicates whether incoming direct access to the communication path block unblock is permitted block prohibited unblock permitted Displays supplemental information about the current system status or the cause of the error Displaying quotation marks Message indicates that no supplemental information exists See Table 3 3 Message L
145. evice WARNING pci FISV scfc scfc SCF command 0OxXXXX receive data sum check error Meaning Detected Sum check error to the receive data of SCF command 0xXXXX Action Check the state of the system board and SCF device WARNING pci FISV scfc scfc SCF command 0xXXXX error Status register OxYYYY Meaning SCF command 0xXXXX terminated abnormally OxYYYY represents the SCF 2 Status register Status register has the following meaning by the value of the least significant four bits OxXXX1 Sending a command to SCF device was repeated ten times due to BUFFER FULL on the SCF device But they were not processed normally OxXXX2 Sending a command to SCF device was repeated fifteen times due to RCI device BUSY on the SCF device But they were not processed normally OxXXX3 Sending a command to SCF device due to th rror on the command Interface with the SCF device OxXXX8 The command and sub command that it was sent to the SCF device was not supported OxXXX9 The command that it was sent to the SCF device failed with the parameter error OxXXXA The command that it was sent to the SCF device was a breach of command path OxXXXB The device specified with the address for the command that it was sent 73 to the SCF device does not exist on the RCI network or RCI is inactive Action Check the state of the SCF device SCFC path changed pci
146. evice Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the power supply unit of the BBB and please contact our customer engineer WARNING FJSVscf thermal alarm on RCI addr O0xXXXXXXXX AAA BBB CCC sub status 0xX6 sense info OxXX OxXX OxXX OxXX 0xZZ OxYY OxNN OxNN 0OxNN Meaning Detected an abnormal temperature sub status 0x06 or 0x86 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x86 and this system is abnormal after this message is displayed the power off of the system is executed 87 When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the cabinet type represents the cabinet number AAA will be displayed only if a cabinet type failure occurred on the following cabinet type Cabinet 0 Main Cabinet Cabinet l Expansion Cabinet Rack I O Rack P Cabinet Power Cabinet BBB represents the unit type represents the unit number BBB will be displayed only if a unit failure occurred on the following units SB System Board PCI BOX PCI BOX PCI DISK BOX PCI Disk BOX DISK DISK Bay Unit XB Crossbar EXT PWR Power Unit CCC represents the sensor type represents the sensor number CCC will be displ
147. failures are detected In this case however the system is not shut down With certain models redundant configurations enable continued operation even when one of the redundant components fails but note that the system will shut down to protect itself if all of the redundant components fail When a component fails a message is displayed on the console You can also check for failures using fjprtdiag 1M and hsadm 1M 1 5 Processing when UPS is connected and power failure o ccurred When UPS is connected to the system and the power failure occurred SCF driver executes the shutdown process At this time SCF driver makes the work file to distinguish the shutdown due to the power failure and starts shutdown SCF driver does not make the work file when the shutdown 1M command is executed or the POWER Switch presses or the shutdown processing due to abnormality The directory and the work file name from which the work file is made are as follows var opt FJSVhwr UPS2 cau The application can add special processing by the power failure by the presence of this work file For example the application prepares shutdown script etc rc0 d In the shutdown script executing special processing when the presence of the work file is judged and the work file exists becomes possible Notes Please end the added processing within keep time backup time of the UPS battery Please consider the keep time of the UPS battery And do not
148. file is not cleared var adm wtmp var adm wtmp old If var adm wtmpx file is cleared If the accounting is enabled the log file is not cleared Solaris 2 6 7 OE var adm vold log var adm vold log old If file size is larger than 256KB var adm sulog var adm sulog 0 1 2 3 If file size is larger than 512KB 207 var cron log var cron olog If file size is larger than 512KB Solaris 9 OE If file size is larger than 462KB Solaris 2 6 7 8 OE var saf _log var saf _log 0 1 If file size is larger than 256KB var saf zsmon log var saf zsmon log 0 1 If file size is larger than 256KB var adm spellhist var adm spellhist old If file size is larger than 256KB var p logs requests var lp logs requests 1 2 At 3 10 every day Solaris 9 OE If the mtime of var p logs requests 1 is older than 7 days Or if file size is larger than 256KB Solaris 2 6 7 8 OE var p logs lpsched var lp logs lpsched 1 2 If the mtime of var p logs lpsched 1 is older than 7 days Solaris 9 OE If the mtime of var lp logs lpsched 1 is older than 7 days Or if file size is larger than 256KB Solaris 2 6 7 8 OE 208 Index SYMBOLS operator call on units connected via RC1 29 A active SUDCOMMANA ccccseeesessteteteteteteteenees 153 AdtIME 2 settee orden Naval deh wees ho 9 alternate key
149. ft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_dev_nregs failed Meaning The register information in the SCF device is incorrect Action Check the state of the SCF device 43 WARNING FJSVscf scf_attach ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_get_soft_iblock_cookie failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_iblock_cookie 9F allocates resources for interrupt processing Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_create_minor_node failed Meaning Failed to incorporate the SCF driver into the system because the creation of the devi
150. g ioctl 2 to the SES device driver failed Action Check the dev es sesX file diskadm ioctlQ USCSICMD failed System call error message Meaning ioctl 2 to the SES device driver failed Action Check the dev es sesX file diskadm sysinfo failed System call error message Meaning sysinfo 2 to the SES device driver failed Action Check the dev es sesX file 6 3 hsadm 1M command Usage hsadm action unit Meaning Displayed when there is an error in the way a command option was used hsadm Only root is allowed to execute this program Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges hsadm dev FJSVhwr pwrctl open failed System call error message Meaning Failed to open the SCF driver 125 Action Make sure that the SCF driver package is installed properly hsadm ioctl SCFIOCALMCTRL failed System call error message Meaning ioctl 2 to the SCF driver failed Action Make sure that the SCF driver package is installed properly hsadm malloc failed System call error message Meaning malloc 3C failed Action Allocate memory or a swap area hsadm kstat_open failed System call error message Meaning kstat_open 3K failed Action Make sure that the SCF driver package is installed properly hsadm fan_unit kstat_lookupQ failed System call error message Meaning Could not read the fan state A
151. g by the value of the least significant four bits OxXX1X Sending a command to SCF device was repeated ten times due to BUFFER FULL on the SCF device But they were not processed normally OxXX2X Sending a command to SCF device was repeated fifteen times due to RCI device BUSY on the SCF device But they were not processed normally OxXX3X Sending a command to SCF device due to th rror on the command Interface with the SCF device OxXX8X The command and sub command that it was sent to the SCF device was not 83 supported OxXX9X The command that it was sent to the SCF device failed with the parameter error OxXXAX The command that it was sent to the SCF device was a breach of command path OxXXBX The device specified with the address for the command that it was sent to the SCF device does not exist on the RCI network or RCI is inactive Action Check the state of the SCF device WARNING pci FISV scfc scfc XXX register parity error Status register OxYYY Y Meaning Parity error interrupt occurred to the XXX register read OxYYYY represents the XXX register XXX is register name SCFI interrupt status SCFI status Action Check the state of the system board and SCF device WARNING pci FJSV scfc scfc EBus2 DMA channel reset timeout Meaning Channel reset timeout occurred to the Ebus 2 DMA Action Check the state of the system board and
152. gt gt lt lt lt fjsnap END gt gt gt ls lt RETURN gt all The collected data is output to exoport home fjsnap all file Example When C option is not specified opt FISVsnap bin fjsnap a T work dev rmt 0 lt RETURN gt Example Add a crash dump file opt FISVsnap bin fjsnap C a T work dev rmt 0 lt RETURN gt Work area size check Uses a directory specified in the T option or environment variable TMPDIR as a work directory work area If the T option and the environment variable TMPDIR are not both specified this command uses tmp directory This command also checks the space capacity of the work area If there is insufficient space on the disk sufficient to execute this command a message is displayed and processing terminates Collect data check Checks whether the file to be collected exists The check result is saved in a log file and an existing file is collected Collect data size check Checks the size of an existing file The total capacity of collect data and work area capacity are displayed as follows lt lt lt needed tmp space size gt gt gt 9999 MB is left in xxxxxxxxx 9999 MB is needed When the total capacity of collect data is larger than the work area capacity a WARNING message is displayed After 30 seconds has lapsed data is collected Pressing the RETURN key enables the user to immediately begin to collect da
153. he mode switch on the operator panel was set to LOCK Action Check the state of the mode switch WARNING FJSVscf AC power down was detected UPS is activated RCI addr 0xXXXXXXX X Meaning Power is now being supplied by the UPS due to a power down Action Check the state of the power supply FJSVscf AC power recovered RCI addr 0xXXXXXXXX Meaning Power was restored on the RCI device OxXXXXXXXX WARNING FJSVscf fan unit failure on RCI addr O0xXXXXXXXX FAN sub status 0xX 1 sense info OXXX OxXX OxXX 0xXX 0xZZ OxYY OxNN 0x00 Meaning Detected a fan unit failure sub status 0x01 or 0x81 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x81 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI FAN represents the fan unit number Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Fan rotation decrease 0x02 Fan rotation stop OxYY is fan number and the number which depends on the corresponding RCI device OxNN is fan tray number and the number which depends on the corresponding RCI device Action Whe
154. ified communication path Displays the class to which the specified Ident a communication path belongs Probe Displays the instance and class to which the specified communication path belongs Recover Restores the specified communication path After the recover subcommand is running this subcommand makes the specified Start WIR communication path available for communicating Active Changes the status of the specified 149 communication path to use Displays the version information for this Version product Displays the usage of the iompadm Help command parameter Specifies a parameter in combination with the subcommands For more information see 8 1 liompadm subcommand EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error 8 1 1 iompadm subcommand 8 1 1 1 info subcommad DESCRIPTION The subcommand info displays the configuration information of the specified instance or all instances and the status of the communication paths Instance refers to a unit of IOMP composition Since there is only dev FJSVhwr fiomp mse0 as the instance of the serial port for the console omitting an instance name is equivalent to specifying it to this subcommand SYNOPSIS usr opt FJSViomp bin iompadm p c fjmse info instance name EXAMPLE When p option is not specified usr opt FISViomp bin iompadm c fjmse info dev FJSVhwr fiomp mse0 IOMP dev FJISVhwr f
155. ile Action Before starting an application set up the necessary license 192 No TCP license server exists Error code 6 Meaning The SERVER line contains no TCP IP port number and the TCP license server is not found in etc services Action Check the license file and the etc services file Cannot find license file Error code 7 Meaning lm_disconn comes after the process has been disconnected from the socket Action Call a Fujitsu customer engineer Encryption code in license file is inconsistent Error code 8 Meaning The code of the license file does not match the other data in the file Action Check the contents in the license file Determine whether Each parameter is not same the contents of the password When the password of the demo license is registered input DEMO as the node lock hostid When the node locked product password is registered input the hostid of the node locked machine When the network locked product password is registered is not the node lock hostid input Invalid host Error code 9 Meaning The hostid specified in a license file does not match the hostid of the machine on which the software is running Action Run the application on a machine with the corresponding hostid or create a valid license Feature has expired Error code 10 Meaning The term of the license has expired Action Acquire a new license 193 Invalid date format in license file Error code 1
156. iomp mse0 Element dev fjse 0 online active block m dev fjse 1 online standby block Node dev FISVhwr mse a Function MPmode false AutoPath true Block true NeedSync false Specify the p option usr opt FIJSViomp bin iompadm p c fjmse info dev FJSVhwr fiomp mse0 IOMP dev FJISVhwr fiomp mse0 Element dev fjse 0 online active block v gt devices pci 83 4000 ebus 1 FJSV se 14 400000 0 fjse dev fjse 1 online standby block gt devices pci 87 4000 ebus 1 FISV se 14 400000 1 fjse 150 Node dev FISVhwr mse a Function MPmode false AutoPath true Block true NeedSync false Table 8 2 Indication Synopsis explains information output in the above examples Table 8 2 Indication Synopsis Format Description IOMP Instance Name Identifies the IOMP Instance name Indicates information about the communication path that comprises the IOMP communication path name status detailed status and access permission If the p option is specified a physical device name will be displayed Element communication path name status details access permission gt physical device name p option Identifies the configured IOMP device name available to users dev console and user access node will be performed to access to the same device Node User Access Node Function Indicates the IOMP features MPmode ttrue false MPmode Simultaneous access to multiple paths A
157. ion Execute the command using root user privileges etc opt FJSVhwr pwrctl property not found Meaning Could not find the var opt FJSVhwr pwrctrld lock file Action Make sure that the SCF driver package is installed properly 127 etc opt FJSVhwr scf conf not found Meaning Could not find the etc opt FJSVhwr scf conf file Action Make sure that the SCF driver package is installed properly opt FJSVhwr sbin scfconf illegal option xxx Meaning The specified option xxx cannot be specified Action Specify the proper option 6 6 scftool 1M command scftool not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges SCF Clock mode is selected The system clock is now based on SCF Clock In this mode when you change the System default clock by using date comannd etc you need to synchronize SCF Clock by the following command scfdate sync Meaning The SCF high resolution clock setting was changed to SCF Clock When the menu is operated by scftool with GP7000 F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER1 100 200 400 600 it is displayed 6 7 scf2tod 1M command usage scf2tod Meaning Displayed when there is an error in the way a command option was used 6 8 srambackup 1M command srambackup not super user Meaning The command was executed using user privileges other than root Actio
158. ion Register the license server according to the contents of the password issued 206 Chapter 12 Server Default Configuration This chapter describes the Log Clear function 12 1 Feature Overview Prevents excessive use of system log files 12 2 Target log file list To prevent excessive use of the system disk space the following log files are regularly cleared var adm messages var log syslog var adm wtmp Note var adm wtmpx Note var adm vold log var adm sulog var cron log var saf _log var saf zsmon log var adm spellhist var lp logs requests var lp logs lpsched Note If the accounting is enabled the log file is not cleared 12 3 Details of log files The Log Clear function is executed at system boot and executed by cron 1M The log files are cleared when it meets the following conditions File Name Backup File Name Log Clear Conditions var adm messages var adm messages 10 1 2 3 If the mtime of var adm messages 0 file is older than 7 days Solaris 9 OE If the mtime of var adm messages 0 file is older than 7 days Or if file size is larger than 512KB Solaris 2 6 7 8 OE var log syslog var log syslog 0 1 2 3 4 5 6 7 If the mtime of var log syslog 0 file is older than 7 days Solaris 9 OE If var adm messages file is cleared Solaris 2 6 7 8 OE var adm wtmpx var adm wtmpx old If file size is larger than 5120KB If the accounting is enabled the log
159. iplied by 1000000 set FJSVscf3 scf_rdctrl_sense_wait monitoring timeout s unit For example etc system is specified as follows set FJSVscf3 scf_rdctrl_sense_wait 2000000 3 Reboot the system For PRIMEPOWER 900 1500 2500 HPC2500 Set up the monitoring timeout in the etc system file as follows Calculating monitoring timeout 2 partitions 2 seconds 3 or more partitions 1 second 0 5 x number of partitions Example 1 8 partitions 2 5 seconds Example 2 4 partitions 3 0 seconds Setting up the etc system file Change the etc system file on all cluster nodes as follows 1 Copy or backup etc system using etc system org Example cp etc system etc system org 2 Add the following to etc system As the timeout is set up in s units set a value equal to the value calculated above multiplied by 1000000 set FJSVscf3 scf_rdctrl_sense_wait monitoring timeout s unit For example etc system is specified for 2 partition configuration as follows set FJSVscf3 scf_rdctrl_sense_wait 2000000 3 Reboot the system 1 6 2 For PRIMECLUSTER When using PRIMECLUSTER you need to set the SCF RCI monitoring timeout according to partition 11 configuration of RCI connecting units Notes You can calculate the timeout using the largest number of partitions in an RCI connecting unit Enable the timeout by rebooting the node For GP7000F model 200 200R 400 400A 400R 6
160. is feature Error code 25 Meaning The version of feature specified in a checkout request is later than the supported version of the license daemon Action Install the latest license server version in the system Request from more license than this feature supports Error code 26 Meaning An attempt to make more checkout requests than is licensed was made Action Restart the application program after other application program end Cannot find ethernet device Error code 29 Meaning The Ethernet device cannot be found 196 Action Call a Fujitsu customer engineer Cannot read license file Error code 30 Meaning It is impossible to read the license file Action This failure occurred with errno EPERM EACCES Check the license file No such attribute Error code 32 Meaning The unknown attribute code is specified by Im_get_addr0 or Im_set_attr Action Call a Fujitsu customer engineer Bad encryption handshake with daemon Error code 33 Meaning The encryption handshake failed Action Call a Fujitsu customer engineer Clock difference too large between client and server Error code 34 Meaning There is too large a system time difference between the license server and the client system in which the application is being executed Action Correct the system clock of each system In the queue for this feature Error code 35 Meaning An application process is queued Action Call a Fujitsu c
161. is not necessary This message might be output in this system at maintenance When this message is frequently displayed it is necessary to investigate Please contact our customer engineer 66 WARNING FJSVscf device sense from RCI addr 0xXXXXXXXX sub status OxYY sense info OxXX OxXX OxXX OxXX OxZZ OxZZ OxZZ OxZZ OxZZ Meaning Detected a sensed information form RCI device addr 0xXXXXXXXX that SCF driver does not support or undefined This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI OxYY shows the event code notified the SCF driver Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows notified sense information and is an irregular value Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please contact our customer engineer When RCI device is this system check whether to operate about Machine Administration WARNING FJSVscf UPS low battery on RCI addr 0xXXXXXXXX was detected sub status 0xX5 sense info OXXX 0xXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected a power supply end of UPS sub status 0x05 or 0x85 of RCI device addr
162. is pressed The default setting is to start the system shutdown process after the POWER switch has been pressed twice Under the double press mode pressing the POWER switch twice will start the shutdown process This prevents the system from being shutdown by accidentally pressing the POWER switch once The first time the POWER switch is pressed you will see a confirmation message on the console Pressing the POWER switch again within the seconds described to 1 2 2Shutdown will start the shutdown process Under the single press mode pressing the POWER switch will immediately start the shutdown process without displaying the confirmation message Under the ignore mode the system will not shutdown even when the POWER switch is pressed When the following models are used default value is two times and setting is not necessary PRIMEPOWER 250 450 650 850 900 1500 2500 HPC2500 Notes When the POWER switch is continuously pressed more than the set value compulsion power supply OFF of the system might be executed Please do not press the POWER switch more than the set value continuously 1 3 2 2 System Time For the following models this section need not be referred to GP7000F model 1000 2000 PRIMEPOWER 1 100 250 450 800 900 1000 1500 2000 2500 HPC2500 This system has two hardware clocks a system standard clockand the SCF high resolution clockthat has a lower degree of error This software makes it possible to use the SCF high
163. ist for more information about displayed messages If the p option is specified a physical device name will be gt devices 34 displayed Table 3 3 Message List gives the description and meaning of displayed messages The item Executable in Table 3 3 Message List indicates either it is possible or impossible to execute the recover subcommand to restore the communication path Table 3 3 Message List Status Message Meaning Executable Communication is Active Good being established The communication Standby Good Bath isiready totr communication but there is in an idle state The communication t d f z Stop Goo path is being stopped SCF device failure offline X occurred Ebus2 Timeout Pbus2 limeout O occurred Command Error Send Sumcheck a Error occurred Receive Sumcheck o Sumcheck Error Error occurred Fail Ebus2 DMA Ebus2 DMA Error transport error O occurred SCF Command Command Timeout Error O Timeout occurred Parity Error X occurred Parity error O Possible However you might be impossible to restore the communication path to work properly with the recover subcommand depending upon the hardware failure X Impossible Unnecessary 3 13 1 2 status subcommand DESCRIPTION status subcommand displays the status of the specified communication path SYNO
164. itoring feature for all specified units EXIT STATUS This command returns the following values 0 Ended normally 1 Error NOTES While hot swapping a power supply hsadm 1M command does not display the state of the power supply which is removed After hot swapping power supplies use hsadm 1M command to confirm that all of the power supplies which are installed are in state Okay Note that only the super user can execute this command 3 3 diskadm 1M NAME diskadm Supports hot swapping of disks SYNOPSYS opt FJIJSVhwr sbin diskadm subcommandpathname AVAILABILITY FJSVscu FJSViscu FJSVpscu FJSVscul FJSVscu2 FJSVscu3 DESCRIPTION diskadm supports hot swapping of disks This command displays disk status 21 The command line must contain one subcommand and at least one pathname For pathname you can specify a physical name logical name or logical controller number cN N is the logical number of the controller Example Physical name devices pci 1f 4000 sd 0 0 a Logical name dev rdsk cOt0d0s0 Controller number cO EXAMPLE subcommand display pathname Displays the status information on specified disks You can specify several path names for pathname in a single command line The following example shows how information is displayed For disks to which power is being supplied diskadm checks them and displays status information For disks to which power is not supplied diskadm displays OFFLINE
165. ity that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 The internal failure of RCI I 0O device 0x01 05 SCF unit self diagnosis error 0x90 RCI network is abnormal status check time out 0x91 RCI address multiple error 0x92 Host node is abnormal 0x93 RCI device connection failure of unregistration 0x94 SCF degeneracy 0x95 Sensor failure of Host node Oxc0 ff Hard error of RCI I O device OxYY shows detailed information of RCI network abnormality event code 0x90 or host node 65 abnormality event code 0x92 Or when the inside abnormality of RCI I O device event code 0x00 detailed information that depends on RCI I O device is shown Other event codes are irregular values and it does not have the meaning Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check RCI address is uniquely assigned to each RCI device there are no RCI cable problems RCI device are turned power on unconfigured RCI devices are not connected or there are no internal failure in RCI devices Please contact our customer engineer paniclcpuX thread OxXXXXXXXX FJSVscf panic request from RCI a
166. kernel resources WARNING FJSVscf scf_attach ddi_get_iblock_cookie failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_iblock_cookie 9F allocates resources for interrupt processing Action Allocate memory since there might not be enough kernel resources 39 WARNING FJSVscf scf_attach ddi_create_minor_node failed Meaning Failed to incorporate the SCF driver into the system because the creation of the device minor node failed Action Make sure there is enough room in the device file system WARNING FJSVscf scf_attach ddi_add_intr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr 9F registers interrupt functions Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attachQ failed Meaning Failed to incorporate the SCF driver into the system Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_map_regs ddi_regs_map_setup failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_map_regs ddi_dev_regsize failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_
167. lated collected datais shown below Solstice Firewall related fw ver Netcompo HICS 1 0 2 related tmp FSUNhics info Netcompo NMC Server Information is collected by trenmcegw dspidcm showpsys vp idcminf d D snap file is created after executing trcidem Ivarlopt FSUNnet lzes lzes trace file is created after executing trclzcs NETSTAGE Information is collected by dspigw infgenigw and transigw 10 6 Collection Procedure List The table below lists the collection procedures Uarp_a Collects the result of arp a a Collects the file that can be specified using Ucp_LICENSE etc opt FSUNlicense FSU_LICENSE_FILE Udf_a Collects the result of df a Udf_e Collects the result of df e Udf_g Collects the result of df g Udf_k Collects the result of df k Udmesg Collects the result of dmesg Udrestat Collects the information related to Dynamic Reconfiguration Ueeprom Collects the result of eeprom Uetc_opt Collects all files and directories under etc opt Collects the result of Ufinddey find dev type d print xargs ls IL Uformat Collects the result of format Uifconfig_a Collects the result of ifconfig a Uipcs_a Collects the result of ipcs a Ulmstat_a Collects the result of Imstat a Uls_lL_dev_dsk Collects the result of ls IL dev dsk 178 Uls_l_binding Collects the result of ls
168. led to initiate UPS switch over procedure when power failed xxx represents the system call that 105 failed Action Allocate memory or a swap area pwrctrld failed to start UPS AC recovery procedure xxx Meaning Failed to initiate UPS procedure after power was restored xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Supply Unit failure procedure xxx Meaning Failed to initiate power supply failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start FAN failure procedure xxx Meaning Failed to initiate fan failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start THERMAL alarm procedure xxx Meaning Failed to initiate abnormal temperature procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to get SCF dump size Meaning Failed to get dump size of SCF driver Action Check the state of the SCF device pwrctrld Illegal SCF dump size Meaning The dump size of the SCF driver was 0 or less Action Check the state of the SCF device 106 pwrctrld Insufficient memory space for SCF dump Meaning Could not get enough memory for the SCF driver dump Action Allocate memory or a swap area pwrctrld SCF dump failed Meaning The SCF d
169. mamand senpinta e OE A AA 139 6 23 iompadm TM command bengisna a ia ene ease AT A A eee aes 140 6 24 DR Connection Script MESSAGE eisernen etara naa aE aN eini E a Er rE A EKRE E E eri ia T 142 Part 2 Serial Port Driver Features PRIMEPOWER800 900 1000 1500 2000 2500 HPC2500 and GP7000F Models T00G 2000 iicc cchckesssisavenece nes seecsstesarasacanseuereioneaevnccvenene 143 Chapter 7 Connecting the Console 2 cccecccececeeeeeeeeeeeeeeeeeeeeneeteeeeneeteeeeeeees 145 7 1 rE EROE ATI EN AAEE EE EEE E EE EET 145 TIA Hardware neient i nE E ENEA E EEA bse east A E e E E E eih 145 Te E0 ETE 1 A E E A A EEE E A AE E Ga EIE E A A AT REEE 145 Te GONGA er n E A A A A AAEE E TA AR 146 7 3 Notice for Using the Serial Ports aseseesssecsisssrerriesisrnsessnnestrnnssrnaaaattansdatanneienaaseanaaaaitaaeenaea 146 7 3 1 PRIMEPOWER 800 1000 2000 GP7000F Models 1000 2000 ccccessssececececeesssseeeeceeeeenseaees 146 7 3 2 PRIMEPOWER 900 1500 2500 HPC2500 ccccccccccecssssssscecececsessnsscesececsesenseaeseesceeseaaeeeeeeeeeenees 146 7 4 The Duplicated OS Console Solaris 8 OE or later cccccceeeeeeeeeeceeceeeeeeeeeceeaeeeeeeeeeteees 146 TEAM OVER VICW ee E edges ba a Saeco cba ea bol eaten ab bob seats E A 146 7 4 2 Configuration cccccccsscccccccscsesscecccccecsesssaesecccecsesssnesecececseseseseeececsesesseseceesceesessaseeecsenssaseeeceseeeneaaees 147 14 3 M anagement comman deen rne taser ses E EE ETE
170. mand File name System call error message Meaning Could not open the file for creating the power log Action Check the file system containing the file for creating the power log dev FJSVhwr pwrctl System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly scfpwrlog fstat System call error message Meaning fstat 2 failed on the file for creating the power log Action Check the file system containing the file for creating the power log lseek System call error message Meaning lseek 2 failed on the file for creating the power log Action Check the file system containing the file for creating the power log read System call error message Meaning read 2 failed on the file for creating the power log Action Check the file system containing the file for creating the power log 130 scfpwrlog write System call error message Meaning write 2 failed on the file for creating the power log Action Check the file system containing the file for creating the power log 6 11 scfreport 1M command Usage scfreport running shutdown Meaning Displayed when there is an error in the way a command option was used scfreport not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges dev FJSVhwr pwrctl System call error message dev FJSVhwr pwrc
171. mand uses tmp directory as a work area if the environment variable TMPDIR is not also defined If the T option and the environment variable TMPDIR are both specified the T option is used output Specifies an output file name or special file name of the output medium C Adds an archive of crash dump file on the end of the archive of collected data in the output file In this case specify a special file name of non rewinding tape device ex dev rmt On as an output medium in the argument output If a special file name of rewinding tape device ex dev rmt 0 is specified in the argument output the archive of collected data gets overwritten by an archive of crash dump file D Specifies where to arrange crash dump files savecore directory in the parameter directory This option is valid only when the C option is specified If the T option is not specified this command collects crash dump files under the Savecore directory that is currently defined on the system If the Savecore directory does not exist on the system crash dump files under var crash uname n are collected Example When the collected data is output to a regular file The file name is all in this case cd export home fjsnap lt RETURN gt opt FISVsnap bin fjsnap a all lt RETURN gt lt lt lt fjsnap START gt gt gt lt lt lt Path name check START gt gt gt 168 lt lt lt Output END gt
172. mber and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the power supply unit of the FEP and please contact our customer engineer WARNING FJSVscf thermal alarm on RCI addr 0xXXXXXXXX SENSOR sub status 0 xX6 sense info OXXX OxXX OxXX 0xXX 0xZZ OxYY 0x00 0x00 Meaning Detected an abnormal temperature sub status 0x06 or 0x86 on RCI device addr 0xXXXXXXXX 53 This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x86 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI SENSOR represents the sensor number Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Ambient temperature low temperature warning 0x02 Ambient temperature low temperature alarm 0x03 Ambient temperature high temperature warning 0x04 Ambient temperature high temperature alarm 0x05 Unit Processor low temperature warning or sensor failure 0x06 Unit Processor low temperature alarm or sensor failure 0x07 Unit Processor high temperat
173. mmunication path failed by various errors This subcommand can be executed if the message offline is not displayed using the info or status subcommands Successfully completing this subcommand changes the communication path into the stop state If you specify a communication path name this subcommand will be performed for the specified communication path If you use the communication path unless essential error cause is removed the communication may be brought back to the fail state depending upon the hardware failure SYNOPSYS usr opt FJSViomp bin iompadm c classname recover dev FJSVhwr fiomp mscf0 Communication PathNamel EXAMPLE usr opt FJSViomp bin iompadm c FJUSVscf3 recover dev FJSVhwr fiomp mscf0 dev FISVhwr scfc0 36 3 13 1 6 start subcommand DESCRIPTION start subcommand makes the communication path in the stop state available Successfully completing this subcommand changes the communication path into the standby or active states If you specify a communication path name this subcommand will be performed for the specified communication path SYNOPSYS usr opt FJSViomp bin iompadm c FJSVscf3 start dev FJSVhwyr fiomp mscf0 Communication Path Name EXAMPLE Example For PRIMEPOWER 850 usr opt FISViomp bin iompadm c FJUSVscf3 start dev FUSVhwr fiomp mscf0 dev FISVhwr scfc0 3 13 1 7 version subcommand DESCRIPTION version subcommand displays the version information for this product
174. n Execute the command using root user privileges 128 WARNING SCF SRAM contents recovered check SCF battery please Meaning The data backed up by the SCF battery was lost and instead was restored from a backup Action Check the SCF battery dev FJSVhwr pwrctl System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly File name System call error message Meaning Could not access the SCF SRAM backup file Action Check the file system containing the SCF SRAM backup file can t rename file name 1 to file name 2 Meaning You cannot change the name of the SCF SRAM backup file Action Check the file system containing the SCF SRAM backup file srambackup out of memory Meaning There is not enough memory Action Allocate memory or a swap area 6 9 scferrlog 1M command dev FJSVhwyr pwrctl System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly File name System call error message Meaning Could not open the file for creating the SCF error log 129 Action Check the file system containing the file for creating the SCF error log scferrlog write System call error message Meaning write 2 failed on the file for creating the SCF error log Action Check the file system containing the file for creating the SCF error log 6 10 scfpwrlog 1M com
175. n RCI I O device is shown Other event codes are irregular values and it does not have the meaning Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check RCI address is uniquely assigned to each RCI device there are no RCI cable problems RCI device are turned power on unconfigured RCI devices are not connected or there are no internal failure in RCI devices Please contact our customer engineer paniclcpuX thread OxXXXXXXXX FJSVscf panic request from RCI addr 0xXXXXXXXX Meaning Action The RCI device that has RCI address of OxXXXXXXXX requested the system panic This message shows the state However at the cluster environment etc another node RCI address 0xXXXXXXXX which detected abnormality issues the panic instruction to this node via RCI And when OS panic is executed this node outputs this message Please investigate this node from information on another node RCI address 0xXXXXXXXX TT NOTICE FJSVscf I O node status sense from RCI addr 0xXXXXXXXX sub status 0x62 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxYY OxYY Meaning Detected a sensed information of I O node status sub status 0x062 from RCI device addr OxXXXXXXXxX This message displays the change of the state of another device connected on the RCI network Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are th
176. n path name EXAMPLE usr opt FISViomp bin iompadm ident dev fjse 0 fjmse 8 1 1 4 probe subcommand DESCRIPTION The subcommand probe displays the instance and class to which the specified communication path belongs SYNOPSIS usr opt FJSViomp bin iompadm probe communication path name EXAMPLE usr opt FISViomp bin iompadm probe dev fjse 0 152 fjmse dev FUSVhwr fiomp mse0 8 1 1 5 recover subcommand DESCRIPTION The subcommand recover restores a communication path failed by error This subcommand can be executed if the message offline is not displayed using the info or status subcommands Successfully completing this subcommand changes the communication path into the stop state If you specify a communication path name this subcommand will be performed for the specified communication path Unless the original error cause is removed communication may revert back to the fail state depending upon the hardware failure SYNOPSIS usr opt FJSViomp bin iompadm c fjmse recover instance name communication path name EXAMPLE usr opt FISViomp bin iompadm c fjmse recover dev FJSVhwr fiomp mse0 dev fjse 0 8 1 1 6 start subcommand DESCRIPTION The subcommand start makes the communication path in the stop state available Successfully completing this subcommand changes the communication path into the standby or active states If you specify a communication path name this subcommand will be perfo
177. n that can be Ucoreadm a specified using coreadm Uprtcfg Collects the information related to Emulex Adapter Uana Collects the files of crash dump analysis Upnavi Collects the information related to Parallelnavi z Collects the information related to Fibre Channel Upfed Driver E Collects the information related to Web BasedAdmin Uwvbs View Collects the information related to Multipath Disk Umplb Control load balance option MPLB 4 paths 8 paths 2 x i Collects the information related to MultiPath Disk Umphd Control Uls_IR_dev Collects the result of ls IR dev Usrfs Collects the information related to SRFS over BLASTBAND HPC Ubbdts Collects the information related to BLASTBAND HPC mw ndate Collects the information related to all modification p information of Fujitsu middleware mw pdate Collects the information related to modification p P information of Fujitsu middleware Uwebsysadmin Collects the information related to WebSysAdmin 10 7 Restricted System Information If you execute this tool as a non privileged user the system information from inaccessible directories and files cannot be collected Also you cannot collect some or all of the system information that the following procedures collect Ucoreadm Uetc_opt Uvar_opt Uformat Uprtvtoc Uhrdconf Uls_l_uname_n Uvar_crash Urc2000 Uscf Utransigw Uinfgenigw Unetcompo_nmc Umetal Umeta2 Uluxadm Uraid
178. n this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the fan unit of the FAN and please contact our customer engineer 75 WARNING FJSVscf power supply unit failure on RCI addr 0xXXXXXXXX AAA sub stat us 0xX2 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0x00 Meaning Detected a power supply unit failure sub status 0x02 or 0x82 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x82 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the power supply unit name represents the power supply unit number FEP SB XB DDC Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x00 An abnormal power supply unit cannot be specified 0x01 04 Power supply and voltage are abnormal 0x05 Power supply unit which depends on device is abnormal OxYY is detailed information which supplements the event code OxZZ 00xNN is a power supply unit type or number and it depends on the corresponding RCI device Action When this message is displayed it is n
179. nced Support Facility Install Guide for installation information If three license server machines are used install the same version of the FLEXIm package on each one 11 2 6 Setting Environment Whenever the node name takeover of 1 1 standby is set with SynfinityClustersystem the state transition procedure is registered according to the following example and you register the resource of state transition procedure to the cluster service etc opt FJSVcluster bin clsetproc c SystemState2 m FSUNlicense etc opt FSUNlicense bin FSUNlicense cluster lt Return gt etc opt FJSVcluster bin claddprocrsc c SystemState2 k FSUNlic 185 m FSUNlicense K BEFORE AFTER L BEFORE S BEFORE lt Return gt The license server cannot be started on the standby node The license server is started when it becomes an operational node 11 2 7 Registering the License Password Follow the procedures described in 11 4Setting of the License Password to register the license password 11 2 8 Starting FLEXIm FLEXIm startsautomatically whenever the system is booted but only if the system has a license file and the machine has been registered as the license server If FLEXlm does not start normally all licensed applications except Node locked products will fail to run 11 3 Troubleshooting If it becomes impossible to issue a license in the system for some reason reboot the license server by the following proced
180. nd displays device information in the RCI configuration table It does not display information on devices that are physically connected but not configured It does displays information on devices that are not connected but remain in the RCI configuration In those cases you must reconfigure using OBP commands EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error SEE ALSO rcinodeadm 1M rcihello 1M 3 10 rcinodeadm 1M NAME rcinodeadm Controls monitoring units connected via RCI SYNOPSYS opt FJSVhwr sbin rcinodeadm address action AVAILABILITY FJSVscu 28 DESCRIPTION rcinodeadm supports the hot swapping of internal power supply and fan in the External Disk Cabinet connected to the system server via RCI This command starts stops the monitoring feature for both devices This command also operates fan test and turns off CHECK LEDs when monitoring is restarted The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER 200 250 400 450 600 OPTIONS address Specifies addresses of units connected via RCI You should specify addresses in a format that rciinfo can display that is 8 digit hexadecimal You can specify the following value for action disable Stops monitoring units connected via RCI enable Restarts monitoring units connected via RCI EXAMPLES rcinodeadm 003006ff disable RCI 003006ff alarm off NOTES If the CH
181. network this message is displayed When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please contact our customer engineer WARNING FJSVscf device sense from RCI addr 0xXXXXXXXX sub status OxYY sense info OXXX OxXX OxXX OxXX 0xXZZ O0xZZ 0xZZ OxZZ Meaning Detected a sensed information form RCI device addr 0xXXXXXXXX that SCF driver does not support or undefined This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI OxYY shows the event code notified the SCF driver Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows notified sense information and is an irregular value Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please c
182. nf V Uprtconf_v Collects the result of prtconf v Uprtconf_vp Collects the result of prtconf vp Uprtdiag_v Collects the result of prtdiag v Uprtvtoc Collects the result of prtvtoc dev rdsk c s2 Ups_ecfjl Collects the result of ps ecfjl Upsrinfo_v Collects the result of psrinfo v Uptree Collects the result of ptree Urc2000 Collects the information related to RC2000 Urpcinfo Collects the result of rpcinfo Urpcinfo_m Collects the result of rpcinfo m Uscf Collects the information related to SCF after executing scfdump scferrlog scfpwrlog and scfhltlog Ushowrev_a Collects the result of showrev a 179 Ushowrev_p Collects the result of showrev p Uswap_l Collects the result of swap l Uswap_s Collects the result of swap s Usysdef Collects the result of sysdef Usysdef_d Collects the result of sysdef d Uuname_a Collects the result of uname a Uuptime Collects the result of uptime Uvar ash Collects minfree file under Savecore directory or Ivar crash uname n Uvar_opt Collects all files and directories under var opt Uvar_sadm_pkg Collects the file of var sadm pkg pkginfo Uypwhich_m Collects the result of ypwhich m Ulpget_list Collects the result of lpget list Ulpstat_Lt Collects the result of lpstat Lt Ulpstat_lt Collects the result of lpstat lt
183. ng kmem_zalloc 9F failed 81 Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_add_intr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr 9F registers interrupt functions Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_get_soft_iblock_cookie failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_iblock_cookie 9F allocates resources for soft interrupt processing Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_attach ddi_add_softintr failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_softintr 9F registers soft interrupt functions Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_dma_alloc ddi_dma_alloc_handle failed Meaning ddi_dma_alloc_handle 9F failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_dma_alloc ddi_dma_mem_alloc failed Meaning ddi_dma_mem_alloc 9F failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_dma_alloc ddi_dma_addr_bind_handle failed Meaning ddi_dma_addr_bind_handle 9F failed
184. ng the SCF device but SCF entered the OFFLINE state again before reporting System Running Action Check the state of the SCF device WARNING FJSVscf SCF did not become online Meaning SCF did not enter the ONLINE state after resetting the SCF device Action Check the state of the SCF device WARNING FJSVscf scf_report_from_intr failed to report System Running Meaning SCF entered the ONLINE state after resetting the SCF device But failed to report System Running due to a full command buffer on the SCF device Action Check the state of the SCF device 52 WARNING FJSVscf fan unit failure on RCI addr 0xXXXXXXXX FAN sub status 0xX1 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0x00 Meaning Detected a fan unit failure sub status 0x01 or 0x81 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x81 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI FAN represents the fan unit number Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Fan rotation decrease 0x02 Fan rotation stop OxYY is fan
185. ning Displayed when there is an error in the way a command option was used rcihello failed to open dev FJSVhwr rcictl Meaning Failed to open SCF driver Action Make sure that the SCF driver package is installed properly rcihello invalid rci address Meaning Invalid RCI address was specified Action Enter a correct RCI address rcihello RCI xxx does not exist Meaning The RCI device that has specified RCI address XXX does not exist Action Enter a correct RCI address rcihello ioctlQ failed Meaning Could not access the SCF driver Action Check the state of the SCF device rcihello ioctlO failed could not set led status on RCI addr xx Meaning Could not set led status on the RCI device of the address displayed Action Check the RCI device of the address displayed 6 18 savewdlog 1M command 134 usage savewdlog directory Meaning Displayed when there is an error in the way a command option was used dev FJSVhwr watchdoglog System call error message Meaning Access to dev FJSVhwr watchdoglog failed Action Make sure that the SCF driver package is installed properly bad hostid format Meaning The gethostid system call failed Action Allocate memory or a swap area savewdlog System call error message Meaning There is not enough memory Action Allocate memory or a swap area File name System call error message Meaning Access to the file failed Action Check the v
186. nse after the load of the memory is lightened The hostid of the license server is incorrect Cause The input hostid of the license server is incorrect word length or configuration characters Action Input the hostid of the server as 8 hexadecimal digits The number of license is incorrect Cause The input number of licenses is incorrect word length or configuration characters Action Input the number of licenses as an integer value of a decimal numeral 203 The license password is incorrect Cause The license password or parameter is incorrect Action Check the hostid feature names version and license password of the license server The hostid of node lock is incorrect Cause The input the node lock hostid is incorrect word length or configuration characters Action Input the node lock hostid as 8 hexadecimal digits The version is incorrect Cause The input version is incorrect word length or configuration characters Action Input the version by the real format The License Server is not registered Action A license server must be registered before a license manager is registered Number of Servers is over MAX Cause The maximum numbers of license servers has already been registered Action Unnecessary servers must be deleted before a license server is changed A license file doesn t exist Cause It is impossible to select Display contents of the License File if the license file doe
187. number and the number which depends on the corresponding RCI device OxNN is fan tray number and the number which depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the fan unit of the FAN and please contact our customer engineer WARNING FJSVscf power supply unit failure on RCI addr 0xXXXXXXXX FEP sub stat us 0xX2 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0x00 Meaning Detected a power supply unit failure sub status 0x02 or 0x82 on RCI device addr 0xXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x82 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI FEP represents the power supply unit number Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x00 An abnormal power supply unit cannot be specified 0x01 04 Power supply and voltage are abnormal 0x05 Power supply unit which depends on device is abnormal OxYY is detailed information which supplements the event code OxZZ 00xNN is a power supply unit type or nu
188. of ddi_get_soft_state 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_attach ddi_get_soft_state_zalloc failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_attach ddi_dev_regsize failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F acquisition of register size Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_attach ddi_create_minor_node failed Meaning Failed to incorporate the FJSVfupd driver into the system because the creation of the device minor node failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_attach ddi_regs_map_setup failed Meaning Failed to incorporate the FJSVfupd driver into the system due to the abnormal termination of ddi_regs_map_setup 9F maps register Action Allocate memory since there might not be enough kernel resources WARNING FJSVfupd fupd_detach ddi_get_soft_state failed Meaning Could not detach the FJSVfupd driver due to the abnormal termination of ddi_get_soft_state 9F allocates an area for the
189. oft_state failed Meaning SCF driver ioctl failed due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_intr ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver 41 Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf fan unit failure FAN Meaning Detected a fan unit failure FAN represents the fan unit number Action Check the fan that had its number displayed WARNING FJSVscf power supply unit failure FEP Meaning Detected a power supply unit failure Action Check the power supply unit WARNING FJSVscf thermal alarm X SENSOR Meaning Detected an abnormal temperature X is a number representing the cause Ambient temperature low temperature warning Ambient temperature low temperature alarm Ambient temperature high temperature warning Ambient temperature high temperature alarm Unit Processor high temperature warning Oo AY DD oO FSF W NY FF unit processor high temperature alarm represents the sensor ID Action Unit Processor low temperature warning or sensor failure Unit Processor low temperature alarm or sensor failure Check the environment where the unit is set up Also make sure there is nothing
190. ol command SYNOPSIS asr opt FJSViomp bin iompadm p c fimse subcommand parameter AVAILABILITY FJSVse or FJSVsec FJSViomp DESCRIPTION iompadm 1M on the duplicated console paths displays the status of communication paths composed of instances the units of duplicated communication paths and restores the communication path where a failure occurs You can display the status of communication paths or restore them using a combination of the specified subcommand and parameter A communication path is a path that is used for communications between a system serial port and System Management Console If in a partition serial ports on the first and second system boards are used as the communication path by default The communication path names will be dev fjse 0 and dev fjse 1 OPTIONS The following options are available c fjmse Specifies a class name fjmse must be specified for a console class p Displays the logical and physical device names of a communication paths If this option is omitted only the logical devices will be displayed subcommand Table 8 1 Subcommand List lists the subcommands you can specify and gives their descriptions Table 8 1 Subcommand List Subcommand Description Displays the configuration information of Info the specified instance or all instances and the status of the communication paths Status Displays the status of the spec
191. ommand name was used Action Check the format of the command iompadm cannot initilize library Invalid Path Meaning There is no valid Plug In or initialization is failed in all the Plug In Action Make sure that the FJSVse or FJSVsec and FJSViomp packages are installed properly In the case driver installed properly call a Fujitsu customer engineer iompadm XXX Invalid Arguments Meaning There is an error in the way the specified option subcommand or parameter was used Action Check the format of the command 155 iompadm XXX No Memory Meaning Insufficient memory occurred during the command execution Action Allocate memory and execute the command again iompadm XXX Invalid Path Number Meaning The path was added deleted to the same class by another process during the command execution Action Execute the command again after completing the job of another process iompadm XXX Invalid Path Meaning There is an error in the way the communication path name was specified in the parameter Action Specify a valid communication path name iompadm XXX Too Many Path Meaning The communication paths specified in the parameter exceeded the maximum number Action Make sure the number of the target devices specified in the environment setting is not exceeding the maximum number iompadm XXX Not Implemented Meaning The specified subcommand dose not support on this product Action Check an availa
192. on paths Action Call a Fujitsu customer engineer 160 WARNING FJMSE 5026 Inappropriate path number Meaning The fjmse driver received an ioctl message which is an inappropriate communication path number Action Call a Fujitsu customer engineer WARNING FJMSE 5027 Can not find corresponding path with Link ID Meaning There is no information to link the communication path Action Call a Fujitsu customer engineer WARNING FJMSE 5028 Can not find corresponding path with Path Number Meaning Detected an internal error regarding control information of communication paths Action Call a Fujitsu customer engineer WARNING FJMSE 5029 Invalid data type Meaning There is no data part of an ioctl message which the fjmse driver received Action Call a Fujitsu customer engineer WARNING FJMSE 5031 Active Path does not exist Meaning There is no communication path in the state active Action Make sure that the communication path in the state active exists Call a Fujitsu customer engineer when there is nothing wrong in the state active WARNING FJMSE 5032 User Access Node does not exist Meaning The fjmse driver received data from serial ports without opening the User Access Node dev FJSVhwr mse a The port monitor ttymon to dev console might not be started properly or the fjmse driver received unnecessary data before the port monitor is started Action Make sure that the port monitor has been sta
193. ond field separated by one or more space or tab of printer related file named Ip under opt FJSVsnap etc directory into etc opt FJSVsnap exclude file to forbid the collection Example opt FJSVsnap etc lp file PROG FILE PHASE gt var spool 1p temp 60 var spool print 60 When you forbid that this tool collects var spool lp temp and var spool print directories write these data into etc opt FJSVsnap exclude file as shown below var spool lp temp 170 var spool print Collect data reference The collected data is restored using tar 1 This command creates a fjsnap d directory in the current directory and arranges the collected data in the directory tree structure defined at collection under the fjsnap d directory Tar xf input lt RETURN gt For input specify a general file name or special file name according to a collect medium The collect file is compressed Use uncompress 1 to uncompress the file before reference If collected data is configured as a directory it is saved as a archive file using tar 1 In the case expand the directory before reference When you restore crash dump files specify a special file name of non rewinding tape device to read an archive of collected data and then restore an archive of crash dump files using tar 1 In this case using tar 1 enables the user to restore an archive of crash dump files after forwarding a tape device using
194. ontact our customer engineer When RCI device is this system check whether to operate about Machine Administration WARNING FJSVscf AC power down was detected on RCI addr 0xXXXXXXXX sub status OxX7 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxYY OxYY Meaning Detected a AC power down sub status 0x07 or 0x87 on RCI device addr 0xXXXXXXXX This message displays abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 Power failure occurred 0xZZ shows the notified sense information and depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the corresponding RCI device and please contact our customer engineer 56 WARNING FJSVscf power supply unit failure on RCI addr 0xXXXXXXXX BE sub statu s 0xX2 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0x00 Meaning Detected a BE power supply unit failure sub status 0x02 or 0x82 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x82 and
195. or 11 7 Error Message List of the setup_license The error message list of the setup_license is described below The messages are divided into the three situations at setup_license startup while setup_license startup executes and when setup_license completes 11 7 1 At setup_license startup Only a system administrator is allowed to execute this program Action Only a super user can use the setup_license 1M A process is currently running You cannot execute more than one command at the same tim e Action Cannot start more than one setup_license 1M at the same time Check to see if the process remains active Cannot write files or directories Cause The directory of the license file does not exist or you do not have the write privileges Command is canceled Cause The command is canceled by user request The object can not be displayed the frame may be too large for the screen Action Set the window size larger than 80x20 Failed to make a backup file of contents file Action Make sure there is enough space in the disk Failed to read the license file Cause A system call error occurred on reading the file 201 System Error fopen filename s errno d Cause The fopen function ended in error Action Check the license file and the directory System Error fgets filename s errno d Cause The fgets function ended in error Action Check the license file and the directory System Er
196. or failure OxYY is UPS number and detail information and it depends on the corresponding RCI device 67 Action When this message is displayed it is necessary to check the abnormality of UPS connected with the RCI device displayed with addr Check to make sure that nothing is wrong with the UPS or please contact our customer engineer WARNING FJSVscf battery alarm on RCI addr 0xXXXXXXXX AAA sub status 0xX3 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY 0x00 0x00 Meaning Detected the lithium battery failure in the device sub status 0x03 or 0x83 of RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the lithium battery type represents the lithium battery number AAA will be displayed only if a lithium battery failure occurred on the following lithium battery NVRAM Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXKXX 0xZZ shows the event code 0x02 Abnormality of low voltage OxYY is the lithium battery number and detail information and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Che
197. or more information see 3 13 liompadm subcommand EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error 3 13 1 iompadm subcommand 3 13 1 1 info subcommand DESCRIPTION info subcommand displays the configuration information of the specified interface or all interfaces and the status of communication paths If no interface name is specified information for all of the interfaces that comprise the IOMP on the system will be displayed In this case the IOMP drivers except for the SCF driver will be included in the information If you want to view information about the SCF driver specify dev FJSVhwr fiomp mscf0 for an interface name SYNOPSYS usr opt FJSViomp bin iompadm p c FJSVscf83 info Interface name EXAMPLE Example For PRIMEPOWER 850 When p option is not specified usr opt FISViomp bin iompadm c FJSVscf3 info dev FJUSVhwr fiomp mscf0 IOMP dev FJISVhwr fiomp mscf0 Element dev FISVhwr scfc0 online active block Good dev FISVhwr scfcl online standby block Good Node dev FJSVhwr pwretl dev FISVhwr pwretl2 dev FISVhwr rcictl dev FISVhwr rcictl2 dev FISVhwr rasctl dev FISVhwr rasctl2 Function MPmode false AutoPath true Block true NeedSync false Specify the p option usr opt FISViomp bin iompadm p c FJSVscf3 info dev FJSVhwr fiomp mscf0 IOMP dev FJISVhwr fiomp mscf0 gt device pseudo FJISVscf 30 1024 msc 0 Element d
198. or panel was set to SECURE FJSVscf allowing debug enter Meaning STOP A was entered WARNING FJSVscf SCF went to offline mode and was restarted Meaning SCF entered the OFFLINE state and was reset Action Check the state of the SCF device NOTICE FJSVscf scf_reset kmem_alloc failed cannot dump firm area Meaning Failed to allocate memory and get a dump from the SCF device firmware area when the SCF device was reset Action Allocate memory since there might not be enough kernel resources NOTICE FJSVscf SCF online Meaning Resetting of the SCF device completed and the device entered the ONLINE state WARNING FJSVscf scf_intr Unexpected POFF interrupt occurred Meaning A POWER switch interrupt occurred while the toggle switch on the operator panel was set to SECURE 46 NOTICE FJSVscf AC power down PFAIL Meaning A cutoff in power supply was detected WARNING FJSVscf scf_intr Unexpected EXTOD interrupt occurred Meaning Detected an EXTOD interrupt Action Check the state of the SCF device WARNING FJSVscf fan unit failure FAN Meaning Detected a fan unit failure FAN represents the fan unit number Action Check the fan that had its number displayed WARNING FJSVscf power supply unit failure FEP Meaning Detected a power supply unit failure FEP represents the power supply unit number Action Check the power supply unit that had its number displayed WARNING FJSVscf
199. ormat and the contents are quite different from fjprtdiag 1M command Please do not use usr platform uname i sbin prtdiag EXIT STATUS This command returns the following values 0 No failures or errors detected on the system gt 0 Failures or errors detected on the system or software errors detected SEE ALSO uname 1 modinfo 1M prtconf 1M psrinfo 1M sysdef 1M syslogd 1M openprom 7D 3 2 hsadm 1M NAME hsadm Supports hot swapping of internal power units and fans SYNOPSYS opt FJSVhwr sbin hsadm action unit AVAILABILITY FJSVscu FJSViscu 20 DESCRIPTION hsadm supports the hot swapping of internal power units and fans This command displays the state of power supplies and fans and starts stops the monitoring feature for both of those devices The command line must contain one action and at least one unit You can specify display enable or disable for action You can specify power and or fan for unit The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER 1 100 200 400 600 EXAMPLES action display unit Displays the status of the specified unit The following shows the display format Power unit Monitoring Mode On Off FEP 0 State Okay Needs maintenance Fan unit Monitoring Mode On Off FAN 0 State Okay Needs maintenance disable unit Stops the monitoring feature for all specified units enable unit Restarts the mon
200. password Valid term Contents 11 4 10 Starting the License Daemon When you edit your license file with the setup_license command the license daemonmust reflect the contents The license daemon sits on the server that manages the license Normally the license server is rebooted at a system reboot In other cases however another procedure is needed to complete the reflection Ifa license file is created start the license daemon by the following procedure etc init d FSUNlicense start lt RETURN gt Ifa license file is modified reflect to the license daemon using the following procedure etc opt FSUNlicense bin lImreread c cat etc opt FSUNlicense FSUN_LICENSE_FILE lt RETURN gt 11 4 11 Alternate Keys Some of the keys used in setup_license command execution may not work In this case used the alternate keys shown below Alternate Key key ji Ctrl p Ctrl n _ Ctrl b gt Ctrl f 11 4 12 NSUNlicnz Package and FSUNIlic Package When you manage product that depends on the NSUNlicnz packageon the same license server machine follow the steps described below 1 Register the license password of the product depending on the FSUNlic packagewith the setup_ license command 2 Add the license password of the product depended on the NSUNlicnz package to the license file created in step 1 by editor The default location is etc opt FSUNlicense license dat 3 Chang
201. power switch procedure xxx Meaning Pressing the POWER switch failed to initiate the shutdown procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start UPS AC down procedure xxx Meaning Failed to initiate UPS switch over procedure when power failed xxx represents the system call that failed Action Allocate memory or a swap area 113 pwrctrld failed to start SCFHALT procedure xxx Meaning Failed to initiate SCFHALT procedure xx represents the system call that failed Action Allocate memory or a swap area pwrctrld Power failure was detected Waiting power to be supplied for n second s RCI addr OxXXX O0xYYY Meaning Power down occurred 0xXXX represents the RCI address of UPS When the dual power feed configuration is defined OxYYY represents the RCI address of UPS pairs Action Check the UPS pwrctrld Power is supplied The system keeps services on RCI addr 0xXXX OxYYY Meaning Power was restored 0xXXX represents the RCI address of UPS When the dual power feed configuration is defined OxYYY represents the address of UPS pairs pwrctrld failed to start SHUTDOWN procedure xxx Meaning Failed to initiate SHUTDOWN procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start RCI POFF procedure xxx Meaning Failed to initiate RCI power down procedure xxx represents the
202. process has been connected Action Reboot the license server License server does not support this feature Error code 18 Meaning The specified feature is not supported Action Check the following It is likely that the valid term of the license has expired The daemon is executed to reflect all changes in the license daemon after a license is registered changed Error in select system call Error code 19 Meaning Fail to system call select Action Call a Fujitsu customer engineer License server busy no majority Error code 20 Meaning The license server is being activated Action After the license server has booted start the application program License file does not support this version Error code 21 Meaning The version in a request is later than the specified version Action Call a Fujitsu customer engineer 195 Feature checkin failure detected at license server Error code 22 Meaning The license cannot be freed Action Check there are not be application problems License server temporarily busy new server connecting Error code 23 Meaning The license daemon is being set up Action After the license daemon has been set up start the application program Users are queued for this feature Error code 24 Meaning Users wishing to use this feature are currently queued Action Start the application program again License server does not support this version of th
203. provides since Solaris 8 OE or later 7 4 1 Overview The duplication of the console path is achieved by including the serial port in the IOMP I O MultiPathing structure according to 7 4 2Configuration The IOMP feature of OS console is supported by the FJSVse package in ESF version 1 7 1 or later and FJSVsec package This package provides the following features If a hardware error occurs on a serial port while the system is running the fjmse driver switches the console device to the secondary port automatically By using the IOMP features the system board with the broken serial port can be changed while the 146 system is running This feature is called DR Dynamic Reconfiguration 7 4 2 Configuration The construction of serial port driver for the duplicated console path is automatically carried out according to OBP environment variable tty conspath and tty sub conspath If the environment variables of OBP OpenBootPROM tty conspath and tty sub conspath are not set two serial ports on the system board installed in the smallest slot number are automatically selected for the console from among the system boards which comprise the partition You can select the serial port for the console by setting the environment variable of OBP Even if the composition of the system board in a partition was changed these environment variables do not change Therefore when partition composition is changed you must reconfirm these
204. pwrctrld pid file Meaning Could not create the PID file Action Check the capacity of the root file system and whether it is mounted in a write enabled state pwrctrid halt system Meaning System shut down due to an error pwrctrld failed to start power switch procedure xxx Meaning Pressing the POWER switch failed to initiate the shutdown procedure xxx represents the system call that failed Action Allocate memory or a swap area 111 pwrctrld failed to start UPS AC down procedure xxx Meaning Failed to initiate UPS switch over procedure when power failed xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start SCFHALT procedure xxx Meaning Failed to initiate SCFHALT procedure xx represents the system call that failed Action Allocate memory or a swap area pwrctrld Power failure was detected Waiting power to be supplied for n second s RCI addr OxXXX OxYYY Meaning Power down occurred 0xXXX represents the RCI address of UPS When the dual power feed configuration is defined OxYYY represents the RCI address of UPS pairs Action Check the UPS pwrctrld Power is supplied The system keeps services on RCI addr 0xXXX OxYYY Meaning Power was restored 0xXXX represents the RCI address of UPS When the dual power feed configuration is defined OxYYY represents the address of UPS pairs pwrctrld failed to start SHUTDOWN procedure xxx
205. rademarks of GLOBEtrotter Software Inc in U S All other products or company names mentioned in this document are claimed as trademark and trade names by their respective companies FUJITSU LIMITED PFU LIMITED May 2004 May 2004 First Edition Notes This manual may not be copied by any means without the expressed written permission of FUJITSU LIMITED FUJITSU LIMITED reserves the right to make changes to this manual without prior notice Copyright 1995 GLOBEtrotter Software Inc Copyright 1995 Software Research Associates Inc All Rights Reserved All Rights Reserved Copyright C FUJITSU LIMITED 2004 All Rights Reserved Copyright C PFU LIMITED 2004 Other Manual Information The following manuals are not supplied with the products as printed or printable manuals Note that you can refer to the following manuals by Solaris 2 6 on Sun Hardware AnswerBook or Solaris 8 on Sun Hardware Collection or Solaris 9 9 02 on Sun Hardware Collection Internet site at http docs sun com No Manual Title 1 SunVTS User s Guide 2 SunVTS Test Reference Manual ii Contents Part 1 SCF Driver Features cc cscs ccricccs sunset dcsnaceecanscca caiuane teanaoen cau henieeeeeauaciees 1 Chapter 1 Main CAabINGly ictenc cattaciccctenesdeateatecendenesdaatdacecundenenswatdaredsutincacenesmceseartecdes 3 dl Feature OVERVIEW viii ac cite ee ila ed A teats ere nh A read A ee envea evans 3
206. rder of registering license servers must be matched with all license files when you use redundant servers 11 4 4 Deleting the License Server Delete a License Server is used when the necessary license server has already been deleted incorrectly or the specified server hardware is changed When 2 Delete a License Server is selected on 11 4 2Top Menu the following menu appears Delete a License Server A List of Servers 1 80f12081 nodel 2 72f026a9 node2 3 0bc3a03f node3 Please choose a server Cursor Key Move Cursor L Screen Redraw D Quit p Previous Page n Next Page Return Key End s Top Page e Bottom Page U UNDO Hostid and node name of the machine registered as the license server are displayed in Server list Move the displayed cursor to the target position then press Return key If the necessary machine has been deleted 187 incorrectly the screen can be reversed by using UNDO once only If it has already been reversed UNDO cannot be used Delete a License Server lt Server Name nodel gt Confirm Delete it AL Screen Redraw D Quit Return Key End When the machine is selected the confirmation screen appears Check the contents of the screen then press the return key again 11 4 5 Registering the License There are two basic types of license Network license Node locked license The registration procedure depends on the license
207. re xx represents the system call that failed Action Allocate memory or a swap area pwrctrld Power failure was detected Waiting power to be supplied for n second s RCI addr OxXXX OxYYY Meaning Power down occurred 0xXXX represents the RCI address of UPS When the dual power feed configuration is defined OxYYY represents the RCI address of UPS pairs Action Check the UPS pwrctrld Power is supplied The system keeps services on RCI addr 0xXXX OxYYY Meaning Power was restored 0xXXX represents the RCI address of UPS When the dual power feed configuration is defined OxYYY represents the address of UPS pairs 109 pwrctrld failed to start SHUTDOWN procedure xxx Meaning Failed to initiate SHUTDOWN procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start RCI POFF procedure xxx Meaning Failed to initiate RCI power down procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Supply Unit failure procedure xxx Meaning Failed to initiate power supply unit failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start FAN failure procedure xxx Meaning Failed to initiate FAN failure procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to sta
208. red the OFFLINE state and was reset Action Follow the output message of after this NOTICE FJSVscf SCF online Meaning Resetting of the SCF device completed and the device entered the ONLINE state WARNING FJSVscf SCF went to offline mode again Meaning SCF entered the ONLINE state after resetting the SCF device but SCF entered the OFFLINE state again Action Check the state of the SCF device 69 WARNING FJSVscf SCF did not become online Meaning SCF did not enter the ONLINE state after resetting the SCF device Action Check the state of the SCF device WARNING FJSVscf scf_get_scftracelog kmem_alloc failed cannot dump firm area Meaning Failed in the memory securing in reset of the SCF device and it failed in the firmware dump collection of the SCF device Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_get_scftracelog kmem_alloc failed cannot event trace area Meaning Failed in the memory securing in reset of the SCF device and it failed in the event trace collection of the SCF device Action Allocate memory since there might not be enough kernel resources NOTICE FJSVscf SCF went to offline mode by firm update Meaning SCF device entered the OFFLINE state by update of the SCF firmware NOTICE FJSVscf SCF went to offline mode by XSCF network activation Meaning SCF device entered the OFFLINE state by network activation of the XSCF 4 1 4
209. regsize 9F gets the register size Action Check the state of the System Monitor WARNING FJSVscf kstat_create failed Meaning kstat_create 9F failed Action Allocate memory since there might not be enough kernel resources 40 WARNING FJSVscf scf_detach ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_getinfo ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_getinfoQ failed Meaning getinfo failed Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_open ddi_get_soft_state failed Meaning Could not open the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_read ddi_get_soft_state failed Meaning Could not read the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_ioctl ddi_get_s
210. resolution clock to adjust the time of the system standard clock The default setting uses only the system standard clock and does not adjust its time Selecting the SCF high resolution clock will cause time to be periodically adjusted allowing more accurate time operation However changing system time by date or a similar command only affects the system standard clock You must use the scfdate 1M command to synchronize the system standard clock and the SCF high resolution clock Do this by executing the following scfdate sync Since system time can be changed by date 1 as well as stime 2 adjtime 2 and settimeofday 3C you must exercise caution when using the SCF high resolution clock In particularly do not use the SCF high resolution clock when running NTP Network Time Protocol software that utilizes the network to synchronize time You can use the scfdate 1M command to display the current time of the SCF high resolution clock When the following models are used the setting is unnecessary However when the system time is changed it is necessary to synchronize SCF high resolution clock by the scfdate 1M command PRIMEPOWER 650 850 1 3 2 8 UPS Operation Time For the following models this section need not be referred to because UPS cannot connect by the UPS interface PRIMEPOWER 1 Connecting a UPS Uninterruptible Power Supply to the system allows you to shut down the system gracefully following a power down
211. rive dump process failed Action Allocate memory pwrctrld var opt FJSVhwr scf dump System call error message Meaning Could not create SCF dump file Action Check the var file system pwrctrld cannot write SCF dump file Meaning Could not create SCF dump file Action Check the var file system pwrctrld failed to start SCFHALT procedure xxx Meaning Failed to initiate SCFHALT procedure xx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start RCI Power Off procedure xxx Meaning Failed to initiate RCI Power Off procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Off procedure xxx Meaning Failed to initiate Power Off procedure xxx represents the system call that failed Action Allocate memory or a swap area 107 pwretrld failed to open var opt FJSVhwr pwrctrld lock Meaning Could not open the var opt FJSVhwr pwrctrld lock file Action Check the var opt FJSVhwr pwrctrld lock file pwrctrld SCF daemon is already running Meaning SCF daemon is already running pwrctrld lockf0 failed Meaning Failed to get the file to be locked by lockf function Action Check the var opt FJSVhwr pwrctrld lock file etc rc0 d KOOFJSVscf scfreport shutdown was executed Meaning Reported the start of system shutdown to SCF device This message might be stored in mess
212. rmed for the specified communication path If omitted this subcommand will attempt to make all communication paths available SYNOPSIS usr opt FJSViomp bin iompadm c fjmse start instance name communication path name EXAMPLE usr opt FISViomp bin iompadm c fjmse start dev FJSVhwr fiomp mse0 dev fjse 0 8 1 1 7 active subcommand DESCRIPTION The subcommand active changes the specified communication path from the standby state to the active state When any other communication path is already in the active state this subcommand changes the communication path into the standby state SYNOPSIS usr opt FJSViomp bin iompadm c fjmse active instance name communication path name EXAMPLE usr opt FISViomp bin iompadm c fjmse active dev FJSVhwr fiomp mse0 dev fjse 1 8 1 1 8 version subcommand DESCRIPTION The subcommand version displays the version information for this product SYNOPSIS usr opt FJSViomp bin iompadm c fjmse version 153 EXAMPLE usr opt FISViomp bin iompadm c fjmse version iompadm Version 1 0 0 1999 12 04 FJIOMP API Level 2 0 fjmse 2 0 1 fjmse API level 1 0 8 1 1 9 help subcommand DESCRIPTION The subcommand help displays the usage of the iompadm command SYNOPSIS usr opt FJSViomp bin iompadm c fjmse help EXAMPLE usr opt FISViomp bin iompadm c fjmse help subcommand active Activates the path help Shows this help message ident Returns the class nam
213. ror fputs filename s errno d Cause The fputs function ended in error Action Check the license file and the directory System Error malloc size d errno d Cause The malloc function ended in error Action Restart the setup_license after the load of the memory is lightened System Error realloc size d errno d Cause The realloc function ended in error Action Restart the setup_license after the load of the memory is lightened The number of license servers is incorrect Cause The license file has four or more SERVER lines Action Register the license server according to the contents of the password issued The daemon line is incorrect Cause The license file has duplicate DAEMON lines J FUJITSU Action Check the license file 202 11 7 2 During the Setup_license execution Command is canceled Cause The command was canceled by the user request System Error fputs filename s errno d Cause The fputs function ended in error Action Check the license file and the directory System Error fopen filename s errno d Cause The fopen function ended in error Action Check the license file and the directory System Error malloc size d errno d Cause The malloc function ended in error Action Restart the setup_license after the load of the memory is lightened System Error realloc size d errno d Cause The realloc function ended in error Action Restart the setup_lice
214. rresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the power supply unit of the RCI device and please contact our customer engineer WARNING FJSVscf I2C error detected error code 0xZZ bus OxYY slave address 0xNN sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0x00 Meaning Detected I2C error This message displays abnormality that this system detected Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ error code 0xZZ is an event code This code is a code to identify the I2C error status and the phase 0x0X I2C write access error Ox1X I2C read access error OxYY bus 0xYY shows the bus number where the I2C error occurs OxNN slave address 0xNN shows the I2C slave address Action Check the state of the SCF device and please contact our customer engineer 57 4 1 3 For PRIMEPOWER 250 450 WARNING FJSVscf _init ddi_soft_state_init failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf _init mod_install failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install 9F incorporates the driver into the system Ac
215. rrupt functions 59 Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_detach ddi_get_soft_state failed Meaning Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING pci FJSV scfc scfc IOCHRDY interrupt occurred Meaning IOCHRDY timeout Ebus2 timeout interrupt occurred Action Check the state of the system board and SCF device WARNING pci FISV scfc scfc DMA host bus error Meaning Host bus error interrupt occurred to the Ebus2 DMA Action Check the state of the system board and SCF device WARNING pci FISV scfc scfc SCF command 0OxXXXX receive data sum check error Meaning Detected Sum check error to the receive data of SCF command 0xXXXX Action Check the state of the system board and SCF device WARNING pci FJSV scfc scfc SCF command 0OxXXXX error Status register OxYYYY Meaning SCF command 0xXXXX terminated abnormally OxYYYY represents the SCF 2 Status register Status register has the following meaning by the value of the least significant four bits OxX1XX Sending a command to SCF device was repeated five times due to RCI BUFFER FULL on the SCF device But they were not processed normally OxX2XX Sending a command to SCF
216. rt THERMAL alarm procedure xxx Meaning Failed to initiate THERMAL alarm procedure xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to start Power Off procedure xxx Meaning Failed to initiate Power Off procedure xxx represents the system call that failed Action Allocate memory or a swap area etc rc0 d KOOFJSVscf scfreport shutdown was executed Meaning Reported the start of system shutdown to SCF device This message might be stored in message log var adm messages as daemon error However it is not abnormal 110 FJSVscf The system power down is executed 30 seconds later Meaning The power off of the system is begun 30 seconds later This message shows the state This message might be stored in message log var adm messages as daemon error However it is not abnormal 5 1 4 For GP7000F models 1000 2000 and PRIMEPOWER 800 1000 2000 pwrctrld Power switch is pressed Press power switch again within 30 seconds to start shutdo wn procedure Meaning The POWER switch was pressed Pressing it again within 30 seconds starts the shutdown process pwrctrld power switch ignored Meaning The POWER switch was pressed but was ignored by the scftool 1M setting pwrctrld failed to start xxx Meaning Could not start the SCF monitoring daemon xxx represents the system call that failed Action Allocate memory or a swap area pwrctrld failed to open
217. rted or the communication path is in the state active Call a Fujitsu customer engineer when this trouble is not solved 161 NOTICE FJMSE 5033 Active status path will not exist Meaning Changed the communication path to the state stop without any other communication paths in the state standby Action Login the system via LAN using root user privileges and execute the iompadm c fjmse start command to re active the console path WARNING FJMSE 5034 Inappropriate data type Meaning The data form of ioctl messages that sets up the terminal information of termio 7I and etc is inappropriate Action Call a Fujitsu customer engineer WARNING FJMSE 5035 Inappropriate message for this node Meaning The fjmse driver received a message of which is not supported to fjmse devices other than User Access Node dev FJSVhwr mse a Action Devices other than User Access Node are not opened to the public Make sure that users access to devices other than User Access Node Call a Fujitsu customer engineer when there is nothing wrong on the User Access Node WARNING FJMSE 5036 Trace mode off fjmse cannot allocate trace data buffer Meaning Could not execute the internal logging feature since the fjmse driver cannot allocate memory resource for the internal logging feature Action There is nothing wrong to use the system Check kernel memory resource size there might not be enough kernel resources WARNING FJMSE 5037 Cannot change
218. s arde Ae eStores Ae eh eae nannaa 155 5 iompadm Command 215 a a hed Seen r T a e did econ sativa ceeds fanaa decd aeaa R Eaa Tan AEA TEN 155 OZ AMSEC DIVER eenia an ET aa avs dau de Oty sce T A ET T 157 9 3 DR Connection Script FUSVSC aoaiina nnani aean aaa Ae oraaa AE aAa ARS AA a 163 Part 3 Maintenance Facility 5eiceiccuise cess cuss cetsecuss ce se cus cetaeGulbe oatbe guise oie guide oa Setguisn seGegess ees 165 Chapter 10 System Data Output Tool ccccccceeeeeceeeeeeeeeeeeeeeeeeeeeeeeeneeeeneees 167 10 1 Feature OvenMiew nis fee E ee al AS le sl eae oli ee El SS 167 10 2 Collection Time and Collection Capacity eccccceceecceeeeeeeeeeseeneeeeseeneeeeeeeeeeeeeseeaeeeeeeaaees 167 10 3 Target SYSteMmeceeiecsctetl as acest teeth deh treed th tt a beeee hl cautaeh eh trevts st icdteh a ccesehl uucadd mbalectehblseathaneeebead 167 10 4 Command Reference zi scctiecetcces daceecrcdd a a conte babeceeatecdoeabeeddetetiectacenetd caetben 167 10 5 Coll cted Data Listerine ee el 171 10 5 Basie System Related soci sacred ce tvosctSexets a estas venue cae E E E E 171 10 5 1 1 Hardware Configuration ccccccsssssessccecesssnsccucccsceceensccecesececeenscaececcesesesseneesecescsesssncesesseenee 172 10 5 1 2 Software Configuration ccc cccccssssecsssseceessssecsesnsecssseececesssecsesssecseseecesusssecsenusecseaessesaaess 172 T0 5 1 3 Environment Setting 24 05cseSs oes Sees ee Peoesabec eh ews ds scoesancew
219. s not exist The feature name and the version have already been registered Cause Same feature name and version can be registered in a license file 204 The license password is not registered Cause It is impossible to change delete the license file since the FEATURE line does not exist in the license file The node name has already been registered Cause A node name of license server cannot be registered twice The hostid has already been registered Cause Hostid of license server cannot be registered twice The feature name and the version have already been registered Cause Same feature name and version cannot be registered in a license file The port number is in correct Action Input the port number as decimal numeral digits Internal error Action There is an internal processing error Call a Fujitsu customer engineer 11 7 3 At setup_license completion Bad Password Cause The license password is incorrect or the password will be invalid if the license server is changed after the registration of the password Action Make sure that the license server has not been changed after the registration of the password Bad Date Action The valid term of the license is incorrect Check the license file 205 Expired Cause The valid term of the license has expired The number of license servers is incorrect Cause The license server to be used can be configured as one or three machines Act
220. sess N E E a a OT 172 VO 25 VAL OS AAAA EEA AOE PEAT ETAT PEE TAEA UR CCE id bn eR ee 174 10 5 1 5 Operation Status v 20 Heese hatin ti ind doen Lhe Sins 176 105 2 Printer Related 1 s shcccehecstedeoteweiee Secs nedectis R E A sbeeugus us ats A E ante ateevsuneiaeci cates 176 10 5 3 High Reliability Related ececssssssssssssssssssssssssssscsssescsssesesesesesesesesesessaesessaesaneaeaseeceeeeeeeeeeess 177 10 54 Storage Array Related mia scdres eh heise tei asda el ae Nee Haid Cade Ea eae GE E N 177 10 5 5 Network Related t c ccc nene e bace aa sca aa EA PUES Reed 178 10 6 Gollection Procedure Listerne roenan ct ha necade nd He Ea AE EAE e RAE ASEE ENA EEEE mien 178 10 7 Restricted System MfOrmatlon sccis aao A Aii 181 Part 4 Common Base Facility ccccccseeeseeeeeeeceeeeeeeeeseeeeeeeeeeeeeeeaasseeeeeeeeeeseees 183 Chapter 11 License Managers i c ncin indie nding ind nd ind ind ind nd ind ind ind nd iad ind na 185 11 Introduction to FLEXIM viiesa a e a E EEA A 185 11 2 How to Introduce FLEXIm Licensed Applications 0 cccccccceecceceeeeeeeeeecenaeeeeeeeseeensneaaeees 185 11 2 1 Selecting the License Server Machine ccccccccccccsessssssecececsesssaeceeccecsessssececececeesesaeeeeeeecsenssaseeees 185 11 2 2 Deciding on License Server Operation ccccccccccceseessssscecececsesssnscecececsesseceeeesesenenseseeeesesenesaeess 185 11 2 3 Setting a License Password n ccccsssssccececsessssececececsensssececc
221. setting is Double System clock setting Specifies whether it is preferred to use the system standard clock or to adjust the time of the system standard clock using the SCF high resolution clock that has a lower degree of error The following models can use this setting GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 The setting can select System Default or SCF clock The default setting is System Default Since system time can be changed by date 1 as well as stime 2 adjtime 2 and settimeofday 3C you must exercise caution when using the SCF high resolution clock In particularly do not use the SCF high resolution clock when running NTP Network Time Protocol software that utilizes the network to synchronize time UPS operation settings Specifies the time from power down to the beginning of shutdown If power does not come up again within the length of delay this software will start the shutdown process The following models can use this setting GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 The delay can be set from 0 second to 9999 seconds The default delay is 5 seconds EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error NOTES Only the super user can execute this command When GP7000F model 1000 2000 and PRIMEPOWER 800 1000 2000 are used and power switch settings is set to differ in each partition the set value of
222. setting is tod Since system time can be changed by date 1 as well as stime 2 adjtime 2 and settimeofday 3C you must exercise caution when using the SCF high resolution clock In particularly do not use the SCF high resolution clock when running NTP Network Time Protocol software that utilizes the network to synchronize time UPS operation settings Specifies the time from power down to the beginning of shutdown If power does not come up again within the length of delay this software will start the shutdown process The following models can use this setting GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 The delay can be set from 0 second to 9999 seconds The default delay is 5 seconds OPTIONS The following options are available If no options are specified the settings remain unchanged 24 p 1 The system begins shutdown when the power switch is pressed once p 2 The system begins shutdown when a power switch is pressed twice You must press the power switch again within 5 seconds before the first press is ignored p off Pressing a power switch is always ignored c scf Adjusts the time of the system standard clock using the SCF high resolution clock This specification is specifiable with GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 200 400 600 c tod Only the system standard clock is used This specification is specifiable with GP7000F model 200 200R 400 4
223. specified as a path name or A controller not supported by the diskadm command was specified or could not access the SCSI Fault LED device driver Action Enter a correct path name Also make sure that the SCF driver package is installed properly diskadm Path name Illegal path name Meaning An illegal path name was specified Action Enter a correct path name diskadm Path name No such device Meaning A controller that does not exist was specified as a path name 120 Action Enter a correct path name diskadm dev FJSVhwr fled open Q failed System call error message Meanin For GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 1 200 400 600 Failed to open the Fault LED device driver For PRIMEPOWER 250 450 650 850 900 1500 2500 H PC 2500 Failed to open the SCF driver Action Make sure that the SCF driver package is installed properly diskadm ioctlQ FLED_IOC_GET_PROP failed System call error message Meaning For GP7000F model 200 200R 400 400A 400R 600 600R and PRIMEPOWER 1 200 400 600 ioctl 2 to the Fault LED device driver failed and the property led control 0 1 could not be read For PRIMEPOWER 250 450 650 850 900 1500 2500 HPC2500 ioctl 2 to the SCF driver failed and the property led control 0O for 79 could not be read Action Make sure that the SCF driver package is installed properly diskadm ioctl FLED_IOC_POWER failed System call error message Meaning ioctl
224. splayed by command that SCF driver offers It also describes what to do when you get error messages The system call error messages listed below are described by man s 2 Intro 6 1 fiprtdiag 1M command fjprtdiag v 1 Meaning Displayed when there is an error in the way a command option was used fjprtdiag Cannot get node name Meaning Could not get node information of OBP Action Check the name property on the root node of OBP fjprtdiag Cannot get property information for memory Meaning Could not get OBP memory information Action Check the simm use and simm status properties on the memory node of OBP fjprtdiag Cannot get model property Meaning Could not get model property information of OBP Action Check the model property on the root node of OBP fjprtdiag Illegal simm use property Meaning The content of the simm use property on the memory node of OBP is illegal Action Check the simm use property fjprtdiag Illegal simm status property Meaning The content of the simm status property on the memory node of OBP is illegal Action Check the simm status property 117 malloc for memory information failed System call error message Meaning Could not allocate a data area for storing memory information Action Allocate memory or a swap area malloc System call error message Meaning Could not allocate memory Action Allocate memory or a swap area fjprtdiag cannot op
225. spool lp temp information var spool print lp print service definition information etc lp Ipstat lt Information collection of print request printer Tee definition and system ls alR var spool lp ls alR var fonts System Walker PrintMGR SE related var opt FJSVppn log etc opt FJSVppn conf BSNPS related var opt FJSVbsnps bsnps etc opt FJSVbsnps bsnps var opt FJSV1p FJSVbsnps var opt FJSV1p ovl var opt FJSV1p page 176 var opt FJSVpralt log etc opt FJSVpralt var opt FSUNmsgm user var opt FSUNmsgm user idx 10 5 8 High Reliability Related The high reliability related collected datais shown below SynfinityCluster Information file is output by clgetrschinfo SynfinityDisk Information file is output by sdxsnap sh SynfinityFile Information file is output by sfxsnap sh SynfinityFile Global Information is output by sfcsnap sh Synfinity VIA Information is output by scnet_error SynfinityCluster HA for Oracle Information is output by clgetoralog etc opt FJSVclora var opt FJSVclora log SynfinityLink etc hanet conf etc opt FJSVhanet var opt FJS Vhanet AP Net Basic Software Information is output by apnet_log 10 5 4 Storage Array Related The storage array related collected datais shown below SPARCstorage Array ls 1 dev es Information is collected by luxadm and ssaadm
226. ss during the command execution Action Execute the command again after completing the job of the other process iompadm XXX Invalid Path Meaning There is an error in the way the path name was specified in the parameter Action Specify a valid path name iompadm XXX Too Many Path Meaning The paths specified in the parameter exceeded the maximum number Action Make sure that the driver is installed properly In the case driver installed properly call a Fujitsu customer engineer iompadm XXX Not Implemented Meaning The specified subcommand dose not support on this product Action Check an available subcommand iompadm XXX Class not Found Meaning Could not find a class that corresponds to specified communication path name Action Check the specified communication path name iompadm XXX Not Supported Meaning Entered the state which is not supported by this class Action Check an available subcommand 141 iompadm XXX IO Error Meaning The command terminated abnormally Action Check the specified path If there is still a problem call a Fujitsu customer engineer iompadm XXX Internal Error Meaning The specified path name does not exist or the command is not accepted Action Check the specified path name or subcommand iompadm XXX Invalid Instance Meaning There is an error in the way the specified path name was used Action Check the specified path name lompadm XXX
227. sscesesscssvesessvescssecesesecssesseneees 327 PCINOD SACI 5 eree en ti eie ei 133 rciNOdeadM 1M oo ceecescssessescssessescseeseeecseeseeesees 28 Yciopeca llmen Sekre nee e EERE 138 rciopecalll1M s sssssssieesisisisiseririririririririririrrrreren 29 recover subcommand ceseseseseeeeeeeeeee es 36 153 redundant SELVEL secesesesececeeeeecececeeeeeceeeees 187 redundant server operation ccceceseeeeeeeeees 187 VOQIStVALION cccceeseeeeseeeeeeeeeneeenens 186 187 188 RESET switch ccccccccsssseceeececsesseceeeeeceesseaees 6 S savewdlog sssssssssosssesesssessssssrssssossssseresssesss 134 SCE driver eeeseesereeseeseserrerrerererere soil SCSI Fault LED Driver 94 SCF high resolution clock re SCF high resolution clock check 625 SCF monitoring daemon 105 SCEZLOU ee e e E EE 128 SCICONL Rie to uano a t27 sefconf 1M sssssessesesesesisrerissesesesrsrereereresesrererrens 24 SCLU ALE on iee E EEE 126 scfdate 1M errre 9 25 s ferrlog nesan Er ten 129 SCEIE OS ea EEE 136 SCOTI CE icc Echoes E A EERE 137 210 SCEPWYIOY AOE EEE E E EEE EEE EEEO 130 SCEPEPONE i025 Meshes ELTE EEEE ET E TENE L31 TRO 0 EEE IEEE AEE 128 SCEEOOl LM eniinn 23 sefwa tchdo sasona g a aarin 131 sefwdtimer OMI ap 26 Serial Port Driver ccccecsceccceeeessstseeeeeeseae 143 settimeocfday 3C ccccccccescescssessescssessesesseeesessess ME Setup n
228. start the system EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error NOTES If you specify enable this function activates when a system saves a memory dump Saving of memory dump fails when saving of memory dump takes more than 14 minutes This function is effective only on models where System Monitor has the watchdog timer function 26 See the documentation provided with each product for information about the watchdog timer function 3 8 rcihello 1M NAME rcihello Controls CHECK LEDs of units connected via RCI SYNOPSYS opt FJSVhwyr sbin rcihello on off address AVAILABILITY FJSVscu DESCRIPTION rcihello controls CHECK LEDs of units connected via RCI The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R PRIMEPOWER 200 400 600 650 850 OPTIONS The following options are available Address Specifies units to be controlled which are connected via RCI If no address is specified all of the units connected via RCI will be controlled Addresses are given in 8 digit hexadecimal on Blinks CHECK LEDs off Stops blinking CHECK LEDs EXAMPLES rcihello on 003001ff NOTES The off option does not necessarily turn off CHECK LEDs The CHECK LEDs with the addresses which you did not specify to blink on the rcihello command line reflect the internal status of the units connected via RCI Where old information remains on RCI devices
229. state of the panel switch WARNING FJSVscf kstat memory allocation error Meaning There is not enough memory Action Allocate memory since there might not be enough kernel resources FJSVscf ignoring debug enter sequence Meaning STOP A was entered while the MODE switch on the operator panel was set to LOCK FJSVscf allowing debug enter Meaning STOP A was entered 4 1 5 For PRIMEPOWER 650 850 900 1500 2500 HPC2500 WARNING FJSVscf _init ddi_soft_state_init failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf _init mod_install failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install 9F incorporates the driver into the system Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources 80 WARNING FJSVscf scf_probe ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the
230. system file Change the etc system file on all the nodes as follows 1 Copy or backup etc system using etc system org Example cp etc system etc system org 2 Add the following to etc system As the timeout is set up in s units set a value equal to the value calculated above multiplied by 1000000 set FJSVscf3 scf_rdctrl_sense_wait monitoring timeout s unit For example etc system is specified for 2 partition configuration as follows set FJSVscf3 scf_rdctrl_sense_wait 2000000 3 Reboot the system 12 Chapter 2 Expansion Disk Cabinet Expansion F ile Unit This chapter describes the RAS Reliability Availability and Serviceability features of the SCSI Expansion Disk Cabinet at the following Expansion Disk Cabinet and SCSI Expansion File Unit at the following Expansion File Unit 2 1 Feature Overview SCF driver offers the following RAS Reliability Availability and Serviceability features of the Expansion Disk Cabinet Expansion File Unit which connects RCI The following features are available When the SCSI Expansion File Unit without RCI SCF driver offers only the hot swapping of internal disks Notifies the system when power supply failures abnormal temperatures or fan breakdowns occur on Expansion Disk Cabinets Expansion File Units This function is not offered to the following models PRIMEPOWER 1 Allows the hot swapping of redundant power supplies and fans on Expansion
231. ta Fjsnap WARNING Not enough space in XXXXXXXXXX lt lt lt job sleep 30s exec return stop INTR c gt gt gt When the size of collect data is too larger to fit the available space press INTR Ctrl C to stop processing specify a work area larger than the size of collect data and execute this command Example Specify a work directory work area with the T option opt FJSVsnap bin fjsnap b T work dev rmt 0 lt RETURN gt Example Define a work directory work area in the environment variable TMPDIR TMPDIR work export TMPDIR lt RETURN gt The total capacity of collect data is a typical value for such data collection Even if the total capacity of collect data is larger than the work area space all data may be able to be collected Data collection When collect data is configured as a file it is copied to a work area 169 Find file name print cpio pdmuL work directory fjsnap d lt RETURN gt When collect data is configured as a directory files under the directory are renamed to directory names using tar 1 and they are arranged into a work area Tar cfh work directory fjsnap d collect directory name tar collect directory lt RETURN gt This command then creates a list file of collected data log file at execution and file attribute information file of collected data fjsnap result List of collected data fisnap elog
232. telus 28 3 11 reiopecall IM ccs eels eed leds ite desde eda AEEA EATE NEA EEEE TEE A 29 iii Bd modeled IM watt ates ee eee neler eee ee nak eee ol 30 S13 1OMPACMICIM 6 se E A E A ie edad aanedede stared E A E E P T TT 31 3 13 1 1loMpadM SUDCOMMANA cccceceseseseseeeeeeeeeeeeeeeeeseseeeeeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeecesenstnaqaqaqags 33 3 13 1 1 info subcommand gt 52 4o5asied hoes Ao daecin aaae eae 33 3 13 1 2 status subcommand en eevee eel ese ede el ek I Lt aoe ee eee 35 3213 1 538 ident SUBCOMMANG ccc s ences civescecedancchebersgedsieeteses uted cezenianchen tecancsadedesas ob nsemnaatet shes EE EEEa rie SEEE 36 3 13 1 4 probe subcOMmmMand e saen i aed E cus E Sol eelane ee ash Nataae E E the 36 3 13 1 5 recover subcommand s src sel tlie elle ek etek Ute ali te ea et ee 36 3 13 16 start SUbCOMIM AN aeaee e e ee E tes Eo r p iapa ee Grabedesnecayaus iK SEEE r Ea tea EES 37 3 13 1 T version subCOMMANG aicci cess cis cosa ces eb iison eE eE EE eirp Teea te e i iaaa 37 3 13 1 8 help sub coMmMan Gives co cccccceecives ceecededsccceveecevccb od steccveeceuceted NEE EE ARA E 37 3 14 Prtdiag M e e Fs Reece a dt rdscue ied a bold banecestadebatabied iebeld soci a a aaa oot hag site ao aaia 38 Chapter 4 Driver Messages 2 lt ccccscc ccenseeeeneneeeeeneteeeeeeeteeeeeneteeseeneseeseesesenseeeetenss 39 AA SGP OVE execs ctivvens devise sic A A A a eee 39 dts t Eor PRIMEPO WHR Mercan hits ie RR est eae eee
233. terminals are called the OS console Solaris 8 OE or later provides for duplication of the console communication path which boosts console path reliability See the following documentation for more information about the structure of the console system PRIMEPOWER Installation Guide GP7000F model 1000 Installation Guide GP7000F model 2000 Installation Guide 7 1 2 Software The serial port driver in the FJSVse for PRIMEPOWER 800 1000 2000 and GP7000F Models 1000 2000 with Solaris 7 OE or later FJSVsef for PRIMEPOWER 800 1000 2000 and GP7000F Models 1000 2000 with Solaris 2 6 OE and FJSVsec for PRIMEPOWER 900 1500 2500 HPC2500 with Solaris 8 OE or later packages included with Enhanced Support Facility ESF controls the onboard serial ports mounted on the system boards In addition to the functions of the se driver included in Solaris OF this serial port driver provides the following RAS Reliability Availability and Serviceability features If a primary main serial port is broken while the system is booting system uses a secondary standby serial port and disables the broken serial port Furthermore when OS is Solaris 8 OE or later the function which dualities the communication path from an onboard serial port to a system console console path is supported The contents of a function of the redundant console path are as follows IOMP T O Multi Pathing function is supported It changes to a standby sid
234. that were previously connected but currently are not rcihello executed with no address control for all of the units connected via RCI will display error messages In this case you must reconfigure RCI setting Note that only the super user can execute this command For the model by whom this command is not offered Machine Administration offers the function equal with this command Please refer to Machine Administration Guide EXIT STATUS This command returns the following values 0 Ended normally gt 0 Error SEE ALSO rciinfo 1M rcinodeadm 1M 3 9 rciinfo 1M NAME rciinfo Displays information on units connected via RCI 27 SYNOPSYS opt FJSVhwr sbin rciinfo AVAILABILITY FJSVscu FJSVpscu FJSVscu2 FJSVscu3 DESCRIPTION rciinfo displays information on units connected via RCI Values displayed such as address status and so on are all given in hexadecimal The following models can use this command GP7000F model 200 200R 400 400A 400R 600 600R 1000 2000 PRIMEPOWER 200 250 400 450 600 650 800 850 900 1000 1500 2000 2500 HPC2500 EXAMPLES rciinfo HOST address 000101ff mode 010038a0 status 80000000 LIST address status device class sub class category 000101ff 9a 0001 04 host 003001ff 90 0400 04 disk 003002ff 90 0400 05 disk HOST displays information on the system server LIST displays information on units connected via RCI together with those on the system server NOTES This comma
235. the failure of the power supply and the fan is notified to the operator and maintains system operation But the system will shut down to protect itself if all of the redundant components fail When the degeneracy due to a partial system failure is done by the initial diagnosis of hardware at the system startup the breakdown parts can be displayed by the command Displays system configuration information on command Controls system shutdown and power cutoff via the POWER switch Allows installation of redundant power supplies and fans and on hot swappable systems makes it possible to replace either of those devices while the system is operating Allows the hot swapping of internal disks during system operation When an external power supply device is connected allows the control of the operator call signal on user terminal board interfaces For the Dynamic Reconfiguration Features abbreviated here after as DR of GP7000F model 1000 2000 and PRIMEPOWER 800 900 1000 1500 2000 2500 SCF driver offers DR Connection Script 1 2 System Operation This section describes the operational procedures of the system from startup to shutdown and explains how to use the controls on the processing unit s operation panel 1 2 1 Boot The system boots up when you press the POWER switchon the processing unit s operation panel Solaris OE will automatically boot if the MODE switch is set to AUTO or LOCK For more information on the MODE swit
236. tion Follow the instruction of the message displayed before this message WARNING FJSVscf pci FISV scfc scfc SCF command 0OxXXXX timeout Meaning The SCF command 0xXXXX could not complete a command within the prescribed time Action Check the state of the system board and SCF device WARNING FJSVscf scf_intr Unexpected POFF interrupt occurred Meaning A POWER switch interrupt occurred while the mode switch on the operator panel was set to LOCK Action Check the state of the mode switch 61 WARNING FJSVscf AC power down was detected UPS is activated RCI addr 0xXXXXXXX X Meaning Power of RCI device addr 0xXXXXXXXX is now being supplied by the UPS due to a power down Action Check the state of the power supply of RCI device WARNING FJSVscf AC power down was detected UPS is activated AAA Meaning Power is now being supplied by the UPS due to a power down of power supply unit AAA represents the power supply unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units PSU Action Check the state of the power supply of power supply unit displayed in AAA WARNING FJSVscf Input power down was detected UPS is activated RCI addr 0xXXXXX XXX Meaning Power of RCI device addr 0xXXXXXXXX is now being supplied by the UPS due to a power down Action Check the state of the power supply of RCI device WARNING FJSVscf
237. tion Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf scf_probe ddi_get_soft_state failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state 9F gets an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING pci FISV scfc scfc scf_probe ddi_dev_nregs failed Meaning The register information in the SCF device is incorrect Action Check the state of the system board WARNING FJSVscf sef_attach ddi_get_iblock_cookie failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_iblock_cookie 9F allocates resources for interrupt processing Action Allocate memory since there might not be enough kernel resources 58 WARNING FJSVscf scf_attach ddi_soft_state_zalloc failed Meaning Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVscf
238. tion need not be referred Refer to Table 1 1 Mode switch of each models for the MODE Switch displayed in each model Table 1 1 Mode switch of each models Models MODE switch GP7000F model 200 200R 400 400A 400R MANUAL AUTO SECURE 600 600R PRIMEPOWER e 7 200 400 600 MANUAL AUTO SECURE GP7000F model 1000 2000 MAINTENANCE UNLOCK LOCK PRIMEPOWER 250 450 A UNLOCK 1 LOCK 1 PRIMEPOWER 650 800 850 900 1000 1500 MAINTENANCE UNLOCK LOCK 2000 2500 HPC2500 Refer to Table 1 2 MODE switch and Function below regarding the differences between the various operating modes Table 1 2 MODE switch and Function POWER switch Console Mode Shut Down Process Power On STOP A MANUAL or Yes Stops in MAINTENANCE as OpenBoot Enters OpenBoot Yes Solaris OE AUTO Yes automatically starts Enters OpenBoot up Yes Stops in UNLOCK Yes OpenBoot Enters OpenBoot No After the power of system is turned SECURE or No on Solaris OE Ignored LOCK i automatically starts up The system was designed to run with the MODE switch set to SECURE LOCK in the majority of situations Setting it to SECURE LOCK offers safer operation than AUTO UNLOCK as it protects against improper use of controls on the operation panel For example if the MODE switch is set to AUTO Solaris OE automatically starts up However when the MODE Switch is set to SECURE or LOCK the system cannot
239. tl2 System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly etc rc0 d KOOFJSVscf scfreport shutdown was executed Meaning Reported the start of system shutdown to SCF device In the case where power down occurred after this message was displayed the system will not boot when power is restored This message might be stored in message log var adm messages as daemon error However it is not abnormal 6 12 Icdecho 1M command dev FJSVhwyr pwrctl System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly 6 13 scfwatchdog 1M command 131 Usage scfwatchdog enable disable Meaning Displayed when there is an error in the way a command option was used scfwatchdog not super user Meaning The command was executed using user privileges other than root Action Execute the command using root user privileges scfwatchdog System call error message Meaning Could not access the SCF driver Action Make sure that the SCF driver package is installed properly 6 14 voltconf 1M command Usage voltconf h 1 n h VH E VL n VN Meaning Displayed when there is an error in the way a command option was used dev FJSVhwr pwrctl System call error message Meaning Could not access dev FJSVhwr pwrctl device Action Check the dev FJSVhwr pwrctl fil
240. unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units PSU FJSVscf power supply was restored AAA Meaning The power supply to power supply unit AAA was restored AAA represents the power supply unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units PSU WARNING FJSVscf fan unit failure on RCI addr 0OxXXXXXXXX AAA BBB sub status 0xX1 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxNN 0xMM Meaning Detected a fan unit failure sub status 0x01 or 0x81 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When sub status is 0x81 and this system is abnormal after this message is displayed the power off of the system is executed When another device on RCI network is abnormal the abnormal is notified to this system through RCI AAA represents the unit type represents the unit number AAA will be displayed only if a unit failure occurred on the following units FANTRAY Fan tray BBB represents the fan unit represents the fan unit number BBB will be displayed only if a fan unit failure occurred on the following units FAN Fan unit Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr Ox
241. ure 1 Stop using all license managed application programs 2 Execute the following command on the license server machine The server will stop etc init d FSUNlicense stop lt RETURN gt 3 Restart the license manager by executing the following command on the license server etc init d FSUNlicense start lt RETURN gt 11 4 Setting of the License Password This section explains how to register a license password to use the software A license password issued by Fujitsu License Password Distribution Center will be used The user must register a license password to the license file A license file name is defined by etc opt FSUNlicense FSUN_LICENSE_FILE file The default location is etc opt FSUNlicense license dat If you want to change modify the FSUN_LICENSE_FILE file by using an editor 11 4 1 Starting the setup_license Registera license password with the setup_licensecommand How to start etc opt FSUNlicense bin setup_license license filename lt RETURN gt lt RETURN gt represents the Return key is depressed Specify a license file name as the argument If omitted the stored file in etc opt FSUNlicense FSUN_LICENSE_FILE file is used The setup_license uses curses 3X Set the environment variable TERM before Set the window size larger than 80x20 when the window is used 11 4 2 Top Menu When the setup_license command is executed the following top menu appears Setup Li
242. ure warning 0x08 unit processor high temperature alarm OxYY is sensor number and it depends on the corresponding RCI device Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check the environment where the unit is set up Also make sure there is nothing wrong with the inside of the RCI device WARNING FJSVscf node error on RCI addr 0xXXXXXXXX sub status 0x08 sense info OXXX OxXX OxXX OxXX 0x00 0xZZ OxYY 0x00 Meaning Detected a node error sub status 0x08 on RCI device addr OxXXXXXXXX This message displays abnormality that this system detected and abnormality that another device connected on the RCI network detected When another device on RCI network is abnormal the abnormal is notified to this system through RCI Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX 0xZZ shows the event code 0x01 The internal failure of RCI I O device 0x01 05 SCF unit self diagnosis error 0x90 RCI network is abnormal status check time out 0x91 RCI address multiple error 0x92 Host node is abnormal 0x93 RCI device connection failure of unregistration 0x94 SCF degeneracy Oxc0O ff Hard error of RCI I O device OxYY shows detailed information of RCI network abnormality event code 0x90 or host node abnormality event code 0x92 Or when the inside abnormalit
243. ures The current contents of the feature name can be selected by cursor from that list Select the intended license from A List of Features the next screen appears by pressing the return key The contents in the screen depend on the license type selected For Network locked products Change an Entry lt Feature Name fn1 gt Version 1 999 Number of Licenses 4 License Password 0BCAC051E7747F0220FB Expiration Date 1 jan 0___ Exit Please enter License Data Feature Name Cursor Key Move Cursor BS BackSpace X Delete a char AT Insert a char L Screen Redraw D Quit AR Clear Field Return Key End For Node locked products Change an Entry lt Feature Name fn 2 gt Version 2 999 Number of Licenses 0 License Password 3B5AA0F13E58142E5FFF Expiration Date 1 jan 0___ Hostid of Node Lock 80f12081 Exit Please enter License Data Feature Name Cursor Key Move Cursor BS BackSpace X Delete a char AT Insert a char L Screen Redraw D Quit AR Clear Field Return Key End 189 Here change the contents Move the display cursor to Exit then press the Return key After this operation the input will be completed 11 4 7 Deleting the License To delete a registered license from a license file use Delete an Entry When 5 Delete a License Password is selected on 11 4 2Top Menu the following screen appears Delete an Entry A List of Features
244. ustomer engineer 197 Feature database corrupted in daemon Error code 36 Meaning There is an internal error in the daemon Action Call a Fujitsu customer engineer Duplicate selection mismatch for this feature Error code 37 Meaning A mismatch application with the grouped mask is executed Action Call a Fujitsu customer engineer Cannot allocate dynamic memory Error code 40 Meaning Sufficient memory can not be secured by malloc Action Restart the application Feature was never checked out Error code 41 Meaning A requested feature has not been checked out Action Check the license file Invalid parameter Error code 42 Meaning An incorrect parameter has been set by lm_set_attr Action Call a Fujitsu customer engineer Clock setting check not available in daemon Error code 47 Meaning A time difference between the client and server is not supported in the daemon Action Call a Fujitsu customer engineer 198 11 6 Command Reference Imstat 1M NAME lmstat Displays the status of the license monitoring daemonand the feature activities SYNOPSYS etc opt FSUNlicense bin Imstat c lic file a All f feature S DAEMON s server_name t timeout_valuel DESCRIPTION lmstat returns the status information of the license daemon user OPTIONS The following options are available c Specifies the license file name that you are using in lic file a
245. utoPath ttrue false AutoPath Automatic path switching Block ttrue false Block Access control NeedSync itrue false NeedSync Synchronization of shared disk The following describes the information listed in Table 8 2 Indication Synopsis in detail status of communication path online The communication path is enabled to communicate In this case active or standby is displayed as the detailed status offline The communication path is disabled to communicate In this case stop or fail is displayed as the detailed status unconfigured The communication path is being detached by Dynamic Reconfiguration In this case disconnected is displayed as the detailed status detailed status active The communication path is enabled for communication or being used for communication standby The communication path is ready for communication but is in an idle state stop The communication path is being stopped fail The communication path is disabled for communication caused by a failure disconnected The communication path is being detached by Dynamic Reconfiguration lt access permission The following information indicates whether incoming direct access to the communication path is permitted block prohibited unblock permitted 151 MPmode Indicates whether the communication path in the IOMP configuration is used at the same time In the case of console since only one communicating path is in an instance
246. ve 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled scsi_probe failed Meaning Failed to attach SCSI Fault LED driver into the system due to the abnormal termination of scsi_probe 9F Action Check the state of SCSI Fault LED device or SCSI Host bus adapter 94 WARNING FJSVsfled ddi_soft_state_zalloc failed Meaning Failed to incorporate SCSI Fault LED driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled ddi_create_minor_node failed Meaning Failed to incorporate SCSI Fault LED driver into the system because the creation of the device minor node failed Action Make sure there is enough room in the devices file system WARNING FJSVsfled scsi_alloc_consistent_buf failed Meaning Failed to allocate kernel resources for SCSI transport Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled resource allocation for request sense packet failed Meaning Failed to allocate kernel resources for SCSI transport Action Allocate memory since there might not be enough kernel resources WARNING FJSVsfled ddi_get_soft_state failed Meaning Failed to retrieve the kernel resources due to the abnormal termination of ddi_get_soft_state 9F Action Allocate memory since there might not be enough kernel resources
247. ver machine must be used for all applications in a local area network LAN 11 2 2 Deciding on License Server Operation The end user can run FLEX m licensed applicationsin either of two ways 1 Run the license manager and applications on the same machine which constitutes a stand alone configuration 2 Run the license manager and applications on separate machines applications are installed on individual machines while the license manager is set up separately Each user runs their application separately 11 2 3 Setting a License Password A user must have a license password to be able to operate FLEXIm licensed applications For information on how to obtain a license password see License Password Application Form attached to the option software 11 2 4 Types of License There are two license types The type is set by each application and cannot be changed 1 Network License A network license limits the number of licenses that can be used for an application on the same network Applications that use network licenses are called Network locked products 2 Node Locked License A node locked license limits application use to a specified machine node Applications that use node locked licenses are called Node locked products 11 2 5 Installing a Package To operate a FLEXIm licensed application you will need to install the application package and the FLEX m package FSUNlic See the document supplied with the application or Enha
248. was changed these environment variables do not change Therefore when partition composition is changed you must reconfirm these variables and they need to be set as the system board which surely exists in the partition If the system boards defined as tty conspath and tty sub conspath do not exist in the partition the serial port of the system board on which the smallest number in a partition was attached will turn into a serial port for consoles However the value of tty conspath and tty sub conspath are not changed Please refer to 7 4 2Configuration about a setup of the duplicated OS console of the host machine Please also refer to the following documents about a setup about console connection PRIMEPOWER USER S MANUAL GP7000F model 1000 USER S MANUAL GP7000F model 2000 USER S MANUAL System Console Software User s Guide 7 3 Notice for Using the Serial Ports 7 3 1 PRIMEPOWER 800 1000 2000 GP7000F Models 1000 2000 Only CCUs can be connected to the onboard serial port Modems connected to the serial ports may not work correctly The device name of the serial port will be dev term fa001 dev term fa002 etc Because the number of this device name is allocated from the instance number of driver this number does not necessarily correspond to the slot number of the system board Do not change the setting of port monitor etc to the serial port for the console The devices which is not used as the
249. y check the state of SCSI Fault LED device WARNING device node name FJSVsfled Unknown Reason Meaning SCSI command error occurred on Fault LED device described as device node name Action If this message is displayed repeatedly check the state of SCSI Fault LED device 4 4 FJSVwdl Driver WARNING FJSVwdl _init ddi_soft_state_init failed Meaning Failed to incorporate the FJSVwdl driver into the system due to the abnormal termination of ddi_soft_state_init 9F Action Allocate memory since there might not be enough kernel resources WARNING FJSVwdl _init mod_install failed Meaning Failed to incorporate the FJSVwdl driver into the system due to the abnormal termination of mod_install 9F incorporates the driver into the system Action Allocate memory since there might not be enough kernel resources 98 WARNING FJSVwdl wdl_attach ddi_get_soft_state_zalloc failed Meaning Failed to incorporate the FJSVwdl driver into the system due to the abnormal termination of ddi_soft_state_zalloc 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJSVwdl wdl_attach ddi_get_soft_state failed Meaning Failed to incorporate the FJSVwdl driver into the system due to the abnormal termination of ddi_get_soft_state 9F allocates an area for the driver Action Allocate memory since there might not be enough kernel resources WARNING FJ
250. y of RCI I O device event code 0x00 detailed information that depends on RCI I O device is shown Other event codes are irregular values and it does not have the meaning Action When this message is displayed it is necessary to check the abnormality of the RCI device displayed with addr Check RCI address is uniquely assigned to each RCI device there are no RCI cable problems RCI device 54 are turned power on unconfigured RCI devices are not connected or there are no internal failure in RCI devices Please contact our customer engineer NOTICE FJSVscf I O node status sense from RCI addr 0xXXXXXXXX sub status 0x62 sense info OXXX OxXX OxXX OxXX 0xZZ OxYY OxYY OxYY Meaning Detected a sensed information of I O node status sub status 0x062 from RCI device addr OxXXXXXXXX This message displays the change of the state of another device connected on the RCI network Sense info shows the following meanings Four bytes of 0xXX show the address of the RCI device and are the same as addr OxXXXXXXXX O0xZZ shows the event code 0x01 RCI I O device connection or power supply reentry 0x02 RCI I O device disconnect OxYY is type or number of RCI I O device and it depends on corresponding RCI I O device Action It is not necessary When this message is frequently displayed it is necessary to investigate the RCI device and please contact our customer engineer WARNING FJSVscf mount error on RCI addr 0xXXXXX

Download Pdf Manuals