Home

PSG Products License Installation Manual

image

Contents

1. gt All Programs gt LeCroy gt PETracer Turn on the power to the host machine or the PCI Express Test Platform 16x2 5GT s 16x5 0GT s 16x8 0GT s At power on the Exerciser initializes itself in approximately five seconds and performs an exhaustive self diagnostic that lasts about forty seconds Update the license key for the system by performing steps 2a through 2c in the section Analyzers on page 12 Please see the Summit PCI Express Multi Lane Protocol Exerciser User Manual on the installation CD ROM for more information PSG Products License Installation Manual 15 Teledyne LeCroy SAS SATA Protocol Suite SAS SATA Protocol Suite Perform the following steps to update the License 1 Connect the Analyzer for which you have purchased the feature upgrade license to the host machine a Connect the Analyzer to a 100 volt to 240 volt 50 Hz to 60 Hz 120 W power outlet OR Connect the provided power adapter into the Analyzer and then plug the power adapter into a 100V 240V 50Hz 60Hz power outlet Sierra M6 1 only b Connect the USB port to a USB port on the host machine using a USB cable Note You can connect using an Ethernet connection too c To start the software select Start gt All Programs gt LeCroy gt SAS Protocol Suite or SATA Protocol Suite d Turn on the power switch At power on the Analyzer will go through initialization as shown on the LCD display Figure 1 20 Fro
2. W power outlet b Connect the USB port to a USB port on the host machine using a USB 2 0 cable Note You can connect using an Ethernet connection too c To start the software select Start gt All Programs gt LeCroy gt USB Protocol Suite d Turn on the power switch At power on the Analyzer will go through initialization as shown on the Updating Analyzer Device window Voyager M3x SN 11461 Updating Firmware ee re Figure 1 25 Updating Analyzer Device Window e Skip to step 2 to update the license via USB If updating via Ethernet follow steps f through k and then proceed to step 2 f Select Setup gt All Connected Devices oy USB Protocol Suite USB 3 0 and 2 0 File Setup Record Generate View Help Ma Display Options Ctrl Shift D 2 Lu Recording Options DELI Update Device Launch Cross amp yne Control Panel Ja Analyzer Network Figure 1 26 Setup Menu g The Analyzer Devices window displays see Figure 1 27 on page 20 h Select the device you want to upgrade and click Connect to display the Connection properties window see Figure 1 27 i Specify one of the actions from the following PSG Products License Installation Manual 19 Teledyne LeCroy USB Protocol Suite 20 m Automatically connect to the device m Ask if want to connect to the device m Take no action If Automatically connect to the device is selected the next time the applica
3. Yes Triggering Filtering 2 Global events Trig Filt Limited Il Yes Triggering Filtering 1 Sequencer with 2 states 6 Global events Install License File Yes Device Emulation Figure 1 28 License Information Window b Select Install License File to display the Select License Key File window see Figure 1 29 on page 22 PSG Products License Installation Manual 21 Teledyne LeCroy USB Protocol Suite Organize Mew folder En Docurnents DI RI Desktop de Downloads Ca p E Recent Places Libraries Bi Documents al Music Pictures E Videos JE Computer El Windows7_OS C O TAI Lenovo_Recoven gt E Mare Je AppNotes de Documents de imageformats di mediasenvice di phonon_backend File name Figure 1 29 Select License Key File Window c Select the License Key file and click Open The License Key is updated Date modified 8 27 2013 12 49 PM 8 27 2013 12 49 PM 8 27 2013 12 49 PM 8 27 2013 12 49 PM 8 27 2013 12 49 PM Type File folder File folder File folder File folder File folder Please see the USB Protocol Suite User Manual on the installation CD ROM for more information 22 PSG Products License Installation Manual How to Contact Teledyne LeCroy Type of Service Call for technical support Fax your questions Write a letter Send e mail Visit Teledyne LeCroy s web site PSG Products License Installation Manual C
4. and Exerciser products Analyzers Perform the following steps to update the License 1 Connect the Analyzer for which you have purchased the feature upgrade license to the host machine a Connect the Analyzer to a 100 volt to 240 volt 50 Hz to 60 Hz 120 W power outlet Connect the USB port to a USB port on the host machine using a USB cable Note You can connect using an Ethernet connection too c To start the software select Start gt All Programs gt LeCroy gt PETracer d Turn on the power switch At power on the Analyzer initializes and performs a self diagnosis The results are reflected by messages on the Summit T3 8 LCD display If the LCD display indicates failure call Teledyne LeCroy Customer Support for assistance e Skip to step 2 to update the license via USB If updating via Ethernet follow steps f through k and then proceed to step 2 f Select Setup gt All Connected Devices File Setup Record Generate View Te Display Options Recording Options tp Generation Options Generation Macros Update Device Calibrate Device cal Launch CrossSync Control Panel RI Analyzer Network J a All Connected Devices Figure 1 16 Setup Menu g The Analyzer Devices window displays see Figure 1 17 on page 13 h Select the device you want to upgrade and click Connect to display the Connection properties window see Figure 1 17 on page 13 12 PSG Products License I
5. NA TELEDYNE LECROY Everywhereyoulook gt Teledyne LeCroy PSG Products License Installation Manual Document Version 1 0 December 2013 Teledyne LeCroy Teledyne LeCroy Protocol Solutions Group Trademarks and Servicemarks Teledyne LeCroy Protocol Solutions Group CATC Trace DDR Protocol Suite FC Protocol Suite IOTA Software Suite Net Protocol Suite PETracer SAS SATA Protocol Suite and USB Protocol Suite are trademarks of Tele dyne LeCroy Microsoft and Windows are registered trademarks of Microsoft Corporation All other trademarks and registered trademarks are property of their respective owners THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE ALL INFORMATION EXAMPLES AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE REPRESENTED WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED USERS ARE FULLY RESPONSIBLE FOR THEIR APPLICATION OF ANY PRODUCTS THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN INFORMATION THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY CONTACT TELEDYNE LECROY FOR A COPY 2013 Teledyne LeCroy All rights reserved This document may be printed and reproduced without additional permission but all copies should contain this copy right notice Teledyne LeCroy 3385
6. Scott Blvd Santa Clara CA 95054 TEL 800 909 7112 USA and Canada TEL 408 653 1260 worldwide ii PSG Products License Installation Manual Chapter 1 License Installation rr 3 DDR Protocol Suite rola 4 FG Protocolo Ue aaa 6 Net Protocol Sutera 9 RETRO iaa 12 ANDOAIN ZONS iaa ei a ARE ai 12 EXT dat 15 SASISATA Protocol SUNT ui aio 16 USB PROLOG ON DU Oui ad 19 Appendix A How to Contact Teledyne LeCroy occocnconcoccoccconcocconccnnncnnnonconnnnns 23 PSG Products License Installation Manual 1 Teledyne LeCroy Contents 2 PSG Products License Installation Manual License Installation Protocol Solutions Group systems provide an extensive and wide set of functionality as part of the basic configuration of our products Certain capabilities and features however need to be enabled through license keys that are provided by Teledyne LeCroy PSG employs two types of licensing mechanisms 1 hardware licensing and 2 software licensing Some products use only hardware licensing some use only software licensing and some may use both The hardware license key is an encrypted proprietary binary file bound to a specific PSG hardware unit serial number When the hardware license key is loaded into the specified hardware unit it unlocks and enables the appropriate functionality The software license key is an encrypted file bound to the Ethernet MAC address of the system where the PSG software applic
7. ained fr Set Alias Name i Connect Add Device Remove Devi IP Settings wy Networks Refresh Device list a From the Help menu click Update License to display the Select License Key File window see Figure 1 9 b Select the License Key file and click Open The License Key is updated PSG Products License Installation Manual Teledyne LeCroy FC Protocol Suite P Date modified Type Mo items match your search File name Files of type Lecroy License Key Files lic x Figure 1 9 Select License Key File Window Please see the SierraFC Protocol Suite User Manual on the installation CD ROM for more information 8 PSG Products License Installation Manual Net Protocol Suite Teledyne LeCroy Net Protocol Suite Perform the following steps to update the License 1 Connect the Analyzer for which you have purchased the feature upgrade license to the host machine a Connect the Analyzer to a 100 volt to 240 volt 50 Hz to 60 Hz 120 W power outlet b Connect the USB port to a USB port on the host machine using a USB cable Note You can connect using an Ethernet connection too c To start the software select Start gt All Programs gt LeCroy gt Net Protocol Suite d Turn on the power switch At power on the Analyzer will go through initialization as shown on the LCD display e Skip to step 2 to update the license via USB If updating via Ethernet fol
8. ation is running The software license key may also be bound to a license server that would enable multiple clients on the network to access the license To enable one or more features that require a license you need to obtain a new license key file from PSG sales protocolsales teledynelecroy com Upon receipt of the license key you must use the respective PSG product s software application to load the license key and enable the features The remainder of this document will describe the procedure for updating hardware licenses for the following products O DDR Protocol Suite see DDR Protocol Suite on page 4 FC Protocol Suite see FC Protocol Suite on page 6 Net Protocol Suite see Net Protocol Suite on page 9 PETracer see PETracer on page 12 SAS SATA Protocol Suite see SAS SATA Protocol Suite on page 16 O USB Protocol Suite see USB Protocol Suite on page 19 OCDOO O IOTA Software Suite uses software licensing Please refer to the document Teledyne LeCroy Software Licensing Guide tor full details on software licensing PSG Products License Installation Manual 3 Teledyne LeCroy DDR Protocol Suite DDR Protocol Suite Perform the following steps to update the License 1 Connect the Kibra system for which you have purchased the feature upgrade license to the host machine a Connect the provided power adapter to the rear of the Analyzer and then plug the power adapter int
9. ay the License Information window see Figure 1 14 on page 11 PSG Products License Installation Manual Net Protocol Suite Teledyne LeCroy 3 License Information SierraWetM4083 5 N 11948 License information for the product Serial Number 11948 0Oxzeacl Available Features Protocol ethernet ves T ProtocoliEtermet Protocosre es ProtocokFC Memory Size 3268 ves memory Size 3268 Memory Size 6468_ no memory Size 64GB Ethemet 106 ves Ethernet OG mee pes ese Oooo Figure 1 14 License Information Window b Select Install License File to display the Open License window see Figure 1 15 c Select the License Key file and click Open The License Key is updated 5 Open License e gt F Program Files 86 LeCroy Net Protocol Suite Windows Bin v Organize v New folder A fee Name Date modified Type Documents HE Desktop de Downloads 1 Recent Places No items match your search A Libraries Documents a Music t Pictures F Videos pi Computer EL Windows7_OS C Lenovo_Recoven hi Network vr File name v License files lic z Figure 1 15 Open License Window Please see the Net Protocol Suite User Manual on the installation CD ROM for more information PSG Products License Installation Manual 11 Teledyne LeCroy PETracer PETracer The following two sections describe the license update procedure for PCI Express protocol Analyzer
10. g Yes Ability to record x16 traffic Figure 1 18 License Information Window b Select Install License File to display the Select license Key File window see Figure 1 19 on page 15 c Select the License Key file and click Open The License Key is updated 14 PSG Products License Installation Manual PETracer Organize JE Computer EE Windows _OS C O TA Lenovo_Recoven _ Teledyne LeCroy 00000 Mew folder Ea Documents Desktop Ja Downloads L El Recent Places Name Date modified Type Mo items match your search A Libraries ni r Documents a Music lee Pictures E Videos 4 la File name Teledyne LeCroy License Key Fi Figure 1 19 Select license Key File Window Please see the Summit PCI Express Multi Lane Protocol Analyzer User Manual on the installation CD ROM for more information Exerciser Perform the following steps to update the License 1 b Connect the Exerciser for which you have purchased the feature upgrade license to either the host machine or the PCI Express Test Platform Connect the Exerciser to a 100 volt to 240 volt 50 Hz to 60 Hz 120 W power outlet using the provided AC power adapter or to the DC power connector if using the PCI Express Test Platform Connect the USB port to a USB port on the host machine using a USB cable Note You can connect using an Ethernet connection too C d To start the software select Start
11. ktop E de Downloads E Recent Places di AppNotes 6 27 2013 1249 PM File folder di Documents 8 27 2013 12 49 PM File folder di imageformats 6 27 2013 1249 PM File folder de mediaservice 8 27 201312 49 PM File folder Je phonon_backend 8 27 201312 49 PM File folder A Libraries E Documents al Music E Pictures E Videos JE Computer E Windows7_0S C E Lenovo_Recoven _ 4 File mame Figure 1 4 Select License Key File Window Please see the DDR Protocol Suite User Manual on the installation CD ROM for more information PSG Products License Installation Manual 5 Teledyne LeCroy FC Protocol Suite FC Protocol Suite Perform the following steps to update the License 1 Connect the Analyzer for which you have purchased the feature upgrade license to host machine a Connect the Analyzer to a 100 volt to 240 volt 50 Hz to 60 Hz 120 W power outlet b Connect the USB port to a USB port on the host machine using a USB cable Note You can connect using an Ethernet connection too c To start the software select Start gt All Programs gt LeCroy gt FC Protocol Suite d Turn on the power switch At power on the Analyzer will go through initialization as shown on the LCD display Figure 1 5 Front Panel Display Message while System is Initializing Figure 1 6 Front Panel Display Message when System is Ready e Skip to step 2 to update the license via USB If updating via Ethernet follo
12. lot Chained MB Remove Devi 0 Automatically connect to he device Askif I want to connect to the device IP Settings Take no action Selected Device Id 05001 04003056 Refresh Device list Figure 1 23 Select Device Window PSG Products License Installation Manual 17 Teledyne LeCroy SAS SATA Protocol Suite 2 Update the License Key for the system a From the Help menu click Update License to display the Select License Key File window see Figure 1 24 b Select the License Key file and click Open The License Key is updated e p Libraries tlie 5 E 7 System Folder Recent Places i Angela Pasari system Folder i Computer l System Folder Adobe Technical Communication Suite 3 5 File folder l hi DS Metwork A System Folder Il Ws I mi ese File name Files of type Teledyne Lecroy License Key Files lic Figure 1 24 SAS Select License Key File window Please see the SAS SATA Protocol Suite User Manual on the installation CD ROM for more information 18 PSG Products License Installation Manual USB Protocol Suite Teledyne LeCroy USB Protocol Suite Perform the following steps to update the License 1 Connect the Analyzer for which you have purchased the feature upgrade license to the host machine a Connect the provided power adapter to the rear of the Analyzer and then plug the power adapter into a 100 volt to 240 volt 50 Hz to 60 Hz 100
13. low steps f through k and then proceed to step 2 Figure 1 10 Front Panel Display Message while System is Initializing Figure 1 11 Front Panel Display Message when System is Available f Select Setup gt Device Management Figure 1 12 Setup Menu g The Device Management window displays see Figure 1 13 on page 10 PSG Products License Installation Manual 9 Teledyne LeCroy Net Protocol Suite 10 ol a amp Device DeviceName Location Status amr Set Alas Nar Add Device te Please specify the appropriate action to take place when next time SN 11948 is detected Remove Device Automatically connect to the device IP Settings Ask if I want to connect to the device x Device Management Update Device Take no action Networks Refresh Device List Close Figure 1 13 Device Management Window h Select the device you want to upgrade and click Connect to display the Connection properties window i Specify one of the actions from the following Automatically connect to the device m Ask if want to connect to the device m Take no action If Automatically connect to the device is selected the next time the application opens the device will be automatically connected j Click OK Click Close to close the Device Management window Update the License Key for the system a From the Help menu select License Information to displ
14. nstallation Manual PETracer Device Location Summit T3 16 SN 1100 Summit 13 16 SM cc Please specify the action to take when next time Summit T3 16 5N 62694 is detected Automatically connect to the device Ask if I want to connect to the device Take no action Select analyzer devices you want to participate in the recording Figure 1 17 Analyzer Devices Window i Specify one of the options from the following m Automatically connect to the device m Ask if want to connect to the device m Take no action Teledyne LeCroy About di Update Device A Update License ig Connect Add Device p IF Settings If Automatically connect to the device is selected the next time the application opens the device will be automatically connected j Click OK k Click Close to close the Analyzer Devices window PSG Products License Installation Manual 13 Teledyne LeCroy PETracer 2 Update the license key for the system a From the Help menu select Display License Information to display the License Information window Summit T3 16 SN 1100 Summit T3 16 5N 62694 License information for the product Serial Number 62694 Available Features Feature Title Purchased Feature Description Embedded Recording Yes Ability to record embedded traffic 9 0 GT s Recording Yes Ability to record 8 0 GT s traffic Bit Tracer Yes Bit Tracer recording x16 Recordin
15. nt Panel Display Message while System is Initializing Figure 1 21 Front Panel Display Message when System is Available e Skip to step 2 to update the license via USB If updating via Ethernet follow steps f through k and then proceed to step 2 f Select Setup gt All Connected Devices see Figure 1 22 on page 17 16 PSG Products License Installation Manual SAS SATA Protocol Suite Teledyne LeCroy TxRxVout amp Preemphasis User Defined Decoding External Trig Setting Update Device All Connected Devices S Find DUT Power Source Control Manage Setup Licenses Preferences Self Test Data Block Figure 1 22 Setup Menu g The Select Device window displays see Figure 1 23 h Select the device you want to upgrade and click Connect to display the Connection properties window see Figure 1 23 i Specify one of the actions from the following m Automatically connect to the device m Ask if want to connect to the device m Take no action If Automatically connect to the device is selected the next time the application opens the device will be automatically connected j Click OK k Click Close to close the Select Device window Device reorder a Set Alias Name Sierra M124 SN 10032 otenivicolieziniemimint li pele ili lot Chained Sierra Mb 1 SIN 534 72 AmibzMb 1 rina pt Chained Sierra M124 SH 10031 12379 is detected lc Chained Sierra M124 5N 12379 EE sa
16. o a 100 volt to 240 volt 50 Hz to 60 Hz 100 W power outlet b Connect the USB port to a UUSB port on the host machine using a USB cable c To start the software select Start gt All Programs gt LeCroy gt DDR Protocol Suite d Turn on the power switch At power on the analyzer will go through initialization as shown on the Updating Analyzer Device window Kibra 480 5N 10026 Updating BusEngine O Figure 1 1 Updating Analyzer Device Window 2 Update the license key for the system a From the Help menu select Update License to display the Analyzer Devices window see Figure 1 3 Tell Teledyne LeCroy User Manual Video Tutorials Display License Information Register Product Online Check For Updates Shortcut List About Figure 1 2 Update License b Click the device so it displays in blue 4 PSG Products License Installation Manual DDR Protocol Suite Teledyne LeCroy Enabled for Capture Device Location Status About 1 Kibra 480 SN 10026 Local Machine Ready Update Device Update License Figure 1 3 Analyzer Devices Window c Click Update License to display the Select License Key File window see Figure 1 4 d Select the License Key file and click Open The License Key is updated Select License Key File Call Program Files x86 LeCroy USE Protocol Suite A ae Organize New folder E Documents Name Date modified HZ Des
17. ontact US and Canada 1 800 909 7112 Worldwide 1 408 653 1260 Worldwide 1 408 727 6622 Teledyne LeCroy Protocol Solutions Group Customer Support 3385 Scott Blvd Santa Clara CA 95054 3115 USA psgsupport teledynelecroy com teledynelecroy com 23 Teledyne LeCroy 24 PSG Products License Installation Manual
18. tion opens the device will be automatically connected j Click OK k Click Close to close the Select Device window Location Status CO About Voyager M3 M3i a sEngine incompatible ae My Update Device A Update License Please specify the action to take when next time Voyager M3 M3i 5N 61752 is detected Automatically connect to the device Ask if I want to connect to the device Take no action Figure 1 27 Analyzer Devices Window 2 Update the License Key for the system a From the Help menu select Display License Information to display the License Information window see Figure 1 28 on page 21 PSG Products License Installation Manual USB Protocol Suite Teledyne LeCroy Voyager M3 M3i 5N 61752 License information for the product Serial Number 61752 Available Features Feature Title Purchased Feature Description Hi Speed Slow Clock No Hi Speed Traffic Generated and Traced at Slow Clock rate Exerciser USB 2 0 Device Emulation Hi Speed Tracing Yes Hi Speed Tracing Enabled Capturing USB 2 0 Yes Capture USB 2 0 traffic Capturing USB 3 0 Yes Capture USB 3 0 traffic Memory Size 512MB No Recording buffer size up to 512MB Memory Size 1GB No Recording buffer size up to 16GB Memory Size 266 No Recording buffer size up to 2GB Memory Size 466 Yes Recording buffer size up to 466 Trig Filt Limited
19. w steps f through k and then proceed to step 2 f Click on Configuration gt All Connected Devices Teledyne LeCroy FC Protocol Sun File View Configuration fd PI Port Configuration Port Calibration Project Setup Tools Help PI License Manager Software Settings User Defined Decoding External Trig Setting Update Sierra Device Setup IF All Connected Devices Figure 1 7 Configuration Menu g The Select Device window displays see Figure 1 8 on page 7 6 PSG Products License Installation Manual FC Protocol Suite Teledyne LeCroy h Select the device you want to upgrade and click Connect to display the Connection properties window see Figure 1 8 on page 7 i Specify one of the actions from the following Automatically connect to the device Ask if want to connect to the device m Take no action If Automatically connect to the device is selected the next time the application opens the device will be automatically connected j Click OK k Click Close to close the Select Device window Device Sierra FC 9 4 SM 63586 Siera _FC 6 Connection properti Please specify the action to take when next time SN 63586 is detected Automatically connect to the device Ask if I want to connect to the device Take no action Selected Device Id Ox00104C00F 862 Figure 1 8 Select Device Window 2 Update the License Key for the system JotCh

Download Pdf Manuals