1.  coming in through the air  combustion control  1  page 6     7  Let the fire burn until it creates the first embers     Note  Thin and dry pieces of wood should be used for lighting   The model 480 NM RS never should be used with the the air combustion control  2  totally closed     Normal Procedure     After lighting    1  Open the door slowly  spread the embers equally over the base of the stove   2  Place logs of approximately 1kg each  horizontally  Don   t overload the appliance and check  the recommended maximum load for your model on the chart for appliance characteristics  7    3  Close the door   4  Choose a position on the air combustion control to achieve a regular lasting burn  avoid an  excessive burn     Note     o You should only reload the stove when the previous load has been completely  consumed  Dont overload your stove     e The paint coating the stove was not subjected to cooking in an oven  so it will  harden with the first time used  Also why on first use  emission of fumes and odors  may occur  Avoid inhalation and ventilate the surrounding space     16     adr    Warning  the appliance was not designed to work with the door open  Do not  open the door of your appliance suddenly  this could overpressure the combustion  chamber causing smoke or even flames to be released into the room        Warning  if you notice any adverse atmospheric conditions which affect the draw  of the smoke it is advisable not to use the appliance     Warning  for well insula
2.  of non combustible materials  If the area where the equipment will be installed no  longer fulfills this requirement  appropriate measures should be taken  for example  a plate  load distribution   Flame resistant material should be placed high temperatures across the back  of the stove  with a minimum thickness of 20 cm     It should be noted that the stove should never be physically restrained in any direction once  should insure themselves the phenomena of thermal expansion that the materials will be  subjected  It is considered prudent that the clearance for expansion is approximately 5 mm to  each side of the fireplace     10    adr    Should never obstruct the vents  It is also desirable that in homes with good insulation and    Or possessing contiguous spaces with exhaustion  is placed a grill vent connected to the  outside of the house with about 100 cm2  Thus supplies the surrounding space with a good  supply of oxygen in order not to exhaust  and air masses moving in the right direction  As for  the air intake grilles must be taken into account that must be positioned so as not to be easy  clogging  When simultaneous with other heating appliances operating shall ensure the  existence of sufficient oxygen     Tubing    You will only get the maximum efficiency from your appliance if the chimney is also efficient   Before installing your ADF appliance check that the chimney is clean and unobstructed  If you  have any difficulties ask a professional to examine the chim
3.  the fan chamber and the fans  This operation should be carried out by a  qualified professional     Over time you may think that your appliance needs painting  In this case  paint the  appliance using a high temperature spray paint provided by ADF  You should only  paint the appliance when it is completely cold  Before painting  carefully cover any  nearby areas that you dont want to paint  glass and hearth  and follow the  instructions on the paint can     Clean the chimney and the neck of the chimney  remove flame deflector  at least  once a year  If necessary ask a qualified professional to do the job     Periodically check  and replace where necessary  the sealing cord around the door     Only use replacement pieces recommended by ADF     This ADF appliance was designed in accordance with existing legislation so as to minimise    eventual risks of a fire in the chimney  However  should this occur     1     Remain calm and check that conditions are safe enough for you to close down the  appliance     Completely close the door of the stove     Completely close the admission of air and the flue        The appliance should then go out by itself due to lack of oxygen     If the area is unsafe  then move away from the danger and immediately call the fire  services for help using the European emergency number     Before using the appliance again  ask a qualified professional to carry out an  inspection of the chimney     18    a adF    The manufacturer of ADF stoves hereby decl
4. ares that all models described  above are in compliance with general safety requirements  However  it  cannot be held responsible if alterations have been made to the product  without due written authorization from the Manufacturer        Antonino Dias Fernandes  Lda    Zona Industrial da Relvinha  Adress Sarzedo  Apartado 55  3304 909 Arganil    Solid fuel li      NP EN 60335 2 102    Applicable regulations      EN 13240 2001    CATIM     Centro de Apoio Tecnol  gico    Industria  Responsible entity for testing Metalomec  nica  Rua dos Pl  tanos  197   Porto       19    8  Troubleshooting    If you follow all the instructions described in this manual you shouldn t    have any problems in enjoying your stove to the full  However  if you do    need to seek technical assistance  first check that      a adr    All the instructions provided in this manual have been followed     II  If there have been any changes around the appliance which could have resulted in  the problem   HI  If the problem corresponds to any of the following points     Problem  s  Possible Cause  s  Correction  s         Flue regulator is closed      Damp or green wood      Dirty or blocked chimney    Burning poorly       Damp or green wood    and  inefficiently    Burning too  fast    The fire goes  out    Fan does not  work    Glass dirty        Dirty or blocked chimney      Not enough wood        Wood is too light      Door not properly adjusted      Sealing cord worn out        Damp or green wood      Th
5. ature  it is subject to different regulations which  should be taken into account and complied with     The need to gain access for the maintenance of the tubing  must be taken into account  therefore the fixing of the tubing  should not be permanent         adr    The chimney must be at least 0 6m from the highest part of the roof  In any other area which  is not the highest point  it should be at least 1 m above the roof  Your chimney should be  cleaned at least once a season            adr    Note     e The equipment must not be cemented its surroundings under any circumstances   leave enough space to be able to expand and contract freely   typically 5mm around the perimeter space  Desirable to connect  at least one of the vents   A q     8  e Should position the air inlet louvers so as not to be blocked         e When installing the appliance  all local regulations  including those relating to  national and european standards must be respected     anti condensation system             1 Step   Fit the smaller part of the pipe  male   in the hole of the equipment  and in the other  extremity of the pipe the diameter will be bigger  female         2 Step   If you want to dock installation accessories  such as  hat  the use the bigger    diameter  female  you must use an union to convert the diameter     13    a adF    SOME OF THE MOST IMPORTANT CURRENT REGULATIONS    e EN13384 1  2003   Chimneys     Thermal and Fluid dynamic calculation methods     Parte 1    EN 2006   Chimn
6. ce from  i mm  combustible materials    Recommended fuel    Width Flue Weight  Height  mm  Depth  mm  outlet  kg    mm   mm         adr    Warnings    A wood burning stove is  by nature  an appliance which operates at high  temperatures  This means paying attention to potential situations of risk and  making sure they are avoided  With this in mind  please pay particular attention  a to children whose natural curiosity may put them at risk and  therefore  should  be kept well away from any heating appliance           The appliance you have just purchased must be installed by a professional to ensure it   s proper  and safe functioning  Remember that all current safety regulations must be complied with  The  appliance must be installed in such a way as to make maintenance easy  The incorrect  installation of the appliance could cause serious damage to the appliance and put people and  property at risk     Before installing your appliance make sure that     The floor is not inflammable    The floor has adequate resistance capacity    The room where the appliance is to be installed is well ventilated    Safety distances from combustible materials are respected as mentioned in this   manual    e Your appliance must be installed in a non permanent way making access to it easy   to ensure the general maintenance of both the appliance and chimney    e The appliance must in no circumstances be cemented into its location     adr    Important Recomendations    It is recommended that yo
7. conditions of installation  handling and maintenance described in this manual    were strictly complied with and no undue use or alterations or modifications to the  appliance have taken place    IV  The warranty is limited to the replacement   repair by ADF or its agent the  admittedly damaged components  and excludes any other sort of coverage or  indemnity     21    adr    10  Warranty Certificate    Qadir    fabricante equipamentos t  rmicos    Warranty Certificate    Name   Adress of the importer     Model  Serial No     Sold to   Adress   Zip    Code     Stamp and Signature  AGENT    Client Signature    Note  The guarantee covers the exchange and or restoration by ADF or its agent of the  components that are acknowledged as damaged and excludes any other type of cover or  compensation such as costs of removal and reinstallation of the appliance    ATTENTION   On being delivered check the state of the appliance    The guarantee only covers damage caused during transport if notification has been given and  marked on the document acknowledging reception of the appliance within a period of 48  hours        22    adf     2 acr          fabricante de equipamentos t  rmicos    www adf pt  adf adf pt    24    
8. d  If you  have any difficulties ask a professional to examine the chimney     Both the height of the chimney  as well as breaks in   pressure in the chimneys are directly related to your      gt   drawing  so the line must have the most straight as  possible  or failing which trajectory never suffer higher  angular deviation at 45    to the vertical  It is also ideal that  the construction of the conduct of the flue passes through  the interior of the building thus ensuring better insulation   and so avoid unwanted condensation originated by  temperature differentials  which sooner or later may  damage the system   Not suitable are the flue ducts from  the outside and without insulation     The chimneys must have individual outputs flues  and is  totally inadvisable grouping several chimneys in collective  behaviors  The outlet smoke pipes must have constant  section from the output of the stove to exhaust venting to  the atmosphere  Recommended for the exits for fumes of  fireplaces dimensions are defined in the Technical data  table    The hat of the chimney must not possess an obstructive  manner towards the currents of outer air  ie it must allow air  to enter through the side exit can access the opposite side  causing no air currents descendants     chap  u da chamin      remate         tubo duplo isolado    tubo    saida de fumos    recuperador       Encasing the fireplace    The appliance must be installed in areas that have adequate bearing capacity and are  composed
9. dgeable of the technical characteristics of  the elements        14    a adF    6  Using the Equipment     820 NM RS    Ignition  LIGHTING   FROM COLD     1 When using this appliance for the first time  or after a prolonged break  it is extremely  important to carefully examine the chimney and check that it is clean and unobstructed  If  you have any problems ask a professional to carry out an inspection    2  The appliance was designed to function intermittently  with intervals for loading wood of  between 45 to 60 min    3  Completely open the air combustion control  At the bottom of the stove place a product  that burns easily  firelighters  pine needles  pine cones or other     4  On the top of this  place small logs stacked horizontally  around 1Kg     5  Leave the door slightly open with a gap of 2cm  This will allow air to get in and help the fire  get started more quickly and efficiently  Keep the air combustion control completely open    6  After 5 to 10 minutes close the door reduce the amount of air coming in through the air  combustion control    7  Let the fire burn until it creates the first embers     Note  Thin and dry pieces of wood should be used for lighting     Normal Procedure     After lighting    1  Open the door slowly  spread the embers equally over the base of the stove   2  Place logs of approximately 1kg each  horizontally  Don t overload the appliance  and check the recommended maximum load for your model on the chart for  appliance characteristic
10. e stove hasn t heated up  sufficiently        Fuction temperature not achived    yet      Energy Break        Damp or green wood           Open flue regulator    Use drier wood        Clean chimney    Use drier wood  Clean chimney        Fill the stove with thicker wood    Readjust the door        Replace the cord    Use drier wood  Heat the stove well by opening  the main air regulator        put more wood      verify connections        Slightly open the air regulator    mechanism        Use drier wood    If the problem still persists  then contact us through our agents  or directly  so that our  technical assistance services can help resolve the problem     20    a adF    9  Warranty conditions    Warranty   We provide five years of guarantee with your ADF appliance  against manufacturing defects    Exclusions   Glass  refractory  Cord   Tape  Are not covered under warranty  because they are    oversized for use temperatures  700 800    C  and its use is beyond the control of  Manufacturer    Flame deflector  grill Ash are not covered by the guarantee because they are subject to  wear and use which is outside the control of the manufacturer  quality of firewood and  operating systems     Conditions of Guarantee     I  The appliance is within the time limits described above  the beginning of this period  of guarantee having begun on the date the appliance was purchased      II  Complaint must be presented to and validated by one of our agents and evaluated  by ADF   HI  The 
11. eys for appliances   EN1857  2003   Chimneys     Components     flue liners   EN1457  1999 Clay ceramic flue liners   Requirements and test methods   EN 1806  2006   Chimneys     clay ceramic flue blocks for single wall chimneys     Requirements and test methods   o EN13069  2005   Chimneys     clay ceramic outer walls for system chimneys    Requirements and test methods   o EN 13063  2006  system chimneys with clay ceramic flue liners   Parte 1   Requirements and test methods for sootfire resistance   e EN 12446  2003   Chimneys     Components   Concrete outer wall elements   o EN 1443  2003   Chimneys     General requirements   e EN1856 1  2003   Chimneys     Requirements for metal chimneys   Part 1  System  chimney products   e EN1856 2  2004   Chimneys     Requirements for metal chimneys     Part 2  Flue liners  and junctions    5  Fan kit diagram    e     The when installing the equipment must be incorporated in the fixed conduit means  to disconnect the apparatus according to the legislation in force    e If the supply cord is damaged  it must be replaced by the manufacturer or his duly  authorized agent  because the power cord has special technical features     Electric Scheme     Operation of the Fan    I     Thermostat  Low Speed  O     off  II  Manual  High Speed       Danger of Electrocution  The tasks of handling and installation of the electrical  components of the stove ADF  must be carried out by professionally qualified  person  aware of the dangers and knowle
12. fabricante de equipamentos t  rmicos      Installation and User s Manual    NM R Series    75    It is important to read this manual carefully before    installing and using your appliance   Vi 05 06 2014       2     adr    Index  1  Introduction 3  2  Diagram of equipment 6  3  Technical Features 7  4  Installation 10  5  Fan kit Diagram 15  6  Using the equiment 16  7  Maintenance and Cleaning 17  8  Troubleshooting 20  9  Warranty Conditions 21  10  Warranty Certificate 22     ac  1  Introduction    First of all we would like to congratulate you on purchasing your ADF appliance    The result of a constant search for innovation and quality  these appliances are designed and  constructed in accordance with both current Portuguese and European legislation   guaranteeing excellent heating performance in the homes where they are installed     So that you can enjoy the full benefits of the appliance you have just purchased  this manual  will provide all the information you need for its correct installation and use     Wood     An ecological form of energy    As a totally renewable resource  wood is the most ecological and economical way of producing  heat in your home  The quantity of CO2 released during the combustion of wood is no higher  than what would be released from its natural decomposition  which has occurred over millions  of years on the planet  The carbon dioxide released in its burning and that which is absorbed  during its useful life balances itself out  which mea
13. ney    Since both the height of the chimney and any breaks in pressure in the chimney are directly  linked to its draft  the conduits should have the straightest trajectory possible or where that is  impossible  the angle shouldn t exceed 45         Vertical  indination is too oe  _  sharp aon  ae inclination  INCORRECT CORRECT    Ideally  the flue conduit is constructed to pass up the inside of the building ensuring a better  insulation and avoiding any unwanted condensation originating from differences in  temperature that sooner or later could damage the system  The tubing should be preferably in  Stainless steel and thermally insulated along its    whole length in order to avoid condensation       specially in cold climates   Chimneys should have a single flue and  the grouping of several chimneys into a    shared flue is not advised        11     0 adr    The flue conduit for conveying the smoke must be unbroken from leaving the appliance to the  evacuation of smoke into the atmosphere     The form of the chimney cap must not obstruct currents of  air from the outside  In other words it must allow the air to  enter through one side and leave through the opposite side  so as not to cause descending currents of air    The sizes recommended for flues for the appliance can be  found on page 7 of this manual  As you can see  the correct  installation of the chimney is a crucial aspect for obtaining  the best possible performance from your appliance and  given  its technical n
14. ns it does not contribute to the green house  warming effect of the planet  Wood ash is a fertiliser that is rich in minerals and easily  absorbed into the atmosphere in a totally ecological way           Combustivel     gt  gt        adr    Wood     Utilization    Selection  Not all wood has the same heating power  In general  opt for hardwoods such as oak  beech    or fruit trees  the wood of which produces beautiful flames and embers that remain glowing for  a long time  Don   t use logs that are too big     Drying   whatever wood you choose it must be completely dry  damp or green wood doesn   t heat as  well  since a large part of the energy is consumed in the evaporation of the water it contains   Besides this  damp wood produces a large amount of smoke and a poor flame  which creates  soot inside the stove  on the glass and in the chimney  Wood should be covered or sheltered  from the rain  but well ventilated  Generally the wood should have a drying period of two  years     Avoid Using  Resinous woods  These woods release a lot of heat but burn quickly and produce embers and  resin which dirty the chimney and the interior of the stove     Never use  Wood which has varnish  paint  cement and glues  These can release toxic gases  besides  damaging the stove     All ADF appliances are designed to burn wood  and only wood that is dry with less than 20   humidity  Damp wood or other types of fuel that are not recommended will lead to loss of  guarantee         a acr    Hea
15. s 7    3  Close the door   4  Choose a position on the air combustion control to achieve a regular lasting burn   avoid an excessive burn     Note     o You should only reload the stove when the previous load has been completely  consumed  Dont overload your stove     e The paint coating the stove was not subjected to cooking in an oven  so it will  harden with the first time used  Also why on first use  emission of fumes and odors  may occur  Avoid inhalation and ventilate the surrounding space     15    a adF    Using the Equipment     480 NM RS    Ignition  LIGHTING   FROM COLD     1  When using this appliance for the first time  or after a prolonged break  it is extremely  important to carefully examine the chimney and check that it is clean and unobstructed  If  you have any problems ask a professional to carry out an inspection    2  The appliance was designed to function intermittently  with intervals for loading wood of  between 45 to 60 min    3  Completely open the air combustion controls   1 and  2 air control     Page 6   At the  bottom of the stove place a product that burns easily  firelighters  pine needles  pine cones  or other     4  On the top of this  place small logs stacked horizontally  around 1Kg     5  Leave the door slightly open with a gap of 2cm  This will allow air to get in and help the fire  get started more quickly and efficiently  Keep the air combustion control completely open    6  After 5 to 10 minutes close the door reduce the amount of air
16. t Propagation    There are three forms of heat transmission in a Biomass appliance  However it is through    radiation that your appliance will gain the greatest benefits     Your stove will naturally cause air movements which are sucked into the lower part and  released through the upper part of the stove  This phenomena is called natural convection   You may also choose to install a fan in the base of the stove in order to obtain forced  convection so as to increase the speed at which hot air is expelled and the distance that it    reaches     The fan is thermally controlled by a thermostat that is calibrated for 50    C  So the venting  begins when this temperature is reached and rests when temperature drops below this value     a  convection    gt        conduction    do do A na hs VAN  Nes      radiation       2  Diagram of equipment    NMR Series       820 NM RS 480 NM RS    PE esse  RE  oe    Air combustion control     820 NM R Released convection    Air combustion control  1     480 NM RS Es Flue outlet  Air combustion control  2     480 NM RS ER Ventilation Control       Note  the compartment beneath the combustion chamber should not be used as wood deposit      adr    3  Thecnical Features    Technical Features ES 820 NMR 480 NMR    Nominal Heat Output 12 5  Energy Efficiency 73  OC    0 6  Average temperature of  450  combustion products  P e  3 5    0 5    Chimney draft at nominal heat  output    Recommended maximum load  Maximum humidity of wood    Minimum distan
17. ted homes or those with forced air ventilation in the  kitchen or bathroom  it is advisable to place a ventilation grill on an outer wall  near the appliance  This safety mechanism is important to avoid oxygen in the  room from running out and from avoiding smoke from the chimney  The area of  the fresh air grill should be at least 100 cm2 and should always be kept unblocked       7 Maintenance and Cleaning    Your appliance can function for various years without any major  maintenance operations  However  you can increase its operating life and  considerably diminish the risks if you follow these principles of Cleaning  and Maintenance        Cleaning and maintenance operations should always be carried out when the  appliance is cold        Cleaning    v empty the ash drawer often  thus preventing contact with the ash grate  your cause  warping bearing in mind that  these may remain hot enough until hours after flame  extinction    Y If sooting appears on the glass it can normally be removed by using a product  specifically for cleaning glass  If the darkening persists  ask ADF or one of our agents  for a cleaning product specifically to remove carbon residues     17    adr    Maitenance    V      Fires    When the cold season ends  a time when your appliance can rest for some time   carry out a comprehensive cleaning of ashes and any residue inside the stove  without using any abrasive products     With the help of an ash vacuum cleaner  vacuum the burning chamber     Clean
18. u engage your installation by a qualified and  accredited professional     Be careful  the outside of the stove is hot  Use suitable protective gloves  whenever you need to touch any of the hot parts of the appliance or to load  the wood while it is working     Don   t use your appliance as an incinerator  Burning domestic waste could  cause the release of toxic fumes and cause the early corrosion of the  components of your appliance and the loss of guarantee     The appliance is not a toy  Keep children away from it     Check that the flue system is properly sized  ensuring a good run and that  meets European standards  so that no undue flue outlet to the surroundings  occurs     Keep any possible inflammable materials at a safe distance from the  appliance  minimum 1 5 metres      NEVER use combustible liquids         The first time you use your stove you may notice a slight odour from the    curing of the paint  Avoid inhaling it and ventilate the surrounding space     well     In the case of adverse weather conditions that disrupt the circulation of  smoke is advisable not to utliza    o equipment        adr    4 Installation    All local regulations  including those that reference to national or  European standards must be adhered to when installing the        g  apparatus  s    The Chimney    You will only get the maximum efficiency from your appliance if the chimney is also efficient   Before installing your ADF appliance check that the chimney is clean and unobstructe
    