Home
R&S®VSE Release Notes
Contents
1. 2 2 1 Software options included in base software The K7 application software package is included in the base software Therefore it does not have a separate item in the installer to be selected 2 2 2 Other Firmware Options within the VSESetup exe File The R amp S VSE K70 application software package has its own installation item and is therefore added to the selection list during the software update Ensure that the checkbox is checked M if the installation is requested The R amp S VSE 1 11 is compatible to the following options VSE K70 VSE K6 VSE K72 VSE K100 _ VSE K102 v1 11 V1 11 v1 11 v1 11 V1 11 VSE K104 V1 11 2 2 3 Enabling Options by Entering Option Key Codes NOTICE This section can be skipped if the option key was entered once To activate application software packages you must enter a license key for validation If a XML file with an option key was sent to you see the install description below The license key is in the device certificate or delivered as a part of the software package The process is performed in the following steps 1 Goto the Help menu 2 Press the License menu item 3 Press the Install Option Button A dialog box is displayed 4 Enter the option key number 5 Press ENTER After a successful validation the message Option Key valid is displayed If the validation failed the option software is not installed 6 Restart the software a Release Notes
2. 65 13 04 88 customersupport asia rohde schwarz com China Phone 86 800 8 10 8828 86 400 650 5896 customersupport china rohde schwarz com r Release Notes 1177 5385 06 03 10
3. instrument search on the local LAN subnet didn t deliver any results This issue is solved 1 4 Known Issues The following table lists the known issues and indicates since which version the issue could be observed V 1 10 The Auto level works unreliable when used with an FSW This will be fixed in an upcoming FSW Firmware version V 1 10 VSE File loading cannot be properly aborted for long capture times or a high sample count Moving the slider bar in the file player is very slow for these scenarios as well V 1 10 VSE K100 104 Using the current FSV or FSW Firmware the Frame Start Offset calculation has an accuracy of less than 100ns with the current FSV and FSW Firmware V 1 10 FSW K72 Using the current FSV or FSW Firmware the Trigger to Frame calculation has an accuracy of less than 100ns V 1 05 IQ Vector display can slow down VSE when choosing a long record length 1 5 Modifications to the Documentation R amp S VSE K70 Vector Signal Analysis Application User Manual The formula used to calculate the standard deviation for parameters in the result summary was changed It is described in the Annex A 8 3 Statistical Evaluations for the Result Summary The formula now being used is Cee nme ay Ou M 1 M with Zo 9 R amp S VSE Software Installation 2 Software Installation The software installation file for the R amp S VSE is one file including the main version number e g VSESetup
4. 1177 5385 06 03 8 Installation of options via XML file 1 Goto the Help menu 2 Press the License menu item 3 Press the button Install Option by XML button A file browser is displayed 4 Select the path to the XML file e g network drive or USB stick 5 Press Select After a successful validation the message Option Key valid is displayed If the validation failed the option software is not installed 6 Reboot the device R amp S VSE Customer Support EUU 3 Customer Support Technical support where and when you need it For quick expert help with any Rohde amp Schwarz equipment contact one of our Customer Support Centers A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation programming or applications of Rohde amp Schwarz equipment Up to date information and upgrades To keep your software up to date and to be informed about new application notes related to your software please send an e mail to the Customer Support Center stating your software and your wish We will take care that you will get the right information Europe Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America Phone 1 410 910 7988 customersupport la rohde schwarz com Asia Pacific Phone 65
5. R amp S VSE Vector Signal Explorer Release Notes Firmware Version V1 11 These Release Notes are for following models of the R amp S VSE Vector Signal Explorer R amp S VSE order no 1320 7500 06 2015 Rohde amp Schwarz GmbH amp Co KG Muehldorfstr 15 81671 Munich Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 E mail mailto info rohde schwarz com Internet http www rohde schwarz com Subject to change R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners The following abbreviations are used throughout this document R amp VSE is abbreviated as R amp S VSE Test and Measurement Release Notes PAD T M 3574 3288 02 02 00 C1 1 EN R amp S VSE Current Version and History E AE Table of Contents 1 Current Version and History ccssseeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 3 T1 New Funcions coo vee coins ws de etree conta cceed a erevecd as vedeunaeeescondasveeeusuedeseasseveseunuerssoatesvecens s 3 1 2 Modified FUNCTIONS s ssis naa nAaR AERAN ANARAN KAANANE AKNAN EARRA 4 1 3 improveme i sanrenannnesone ctte tite en ee tede eens te dectee ta denttectdeceeetadecttedetecteetidentene 5 1 4 Known ISSUGS EAREN e EANAN nE aR 6 1 5 Modifications to the Documentation ssssssssuunnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn nnn 6 2 Software Installation occ occccviiseieseseccecerecresesetwecscereneser
6. _V1 11 exe It will be referred as VSESetup exe later in the text The file can be found on the Rohde amp Schwarz web page NOTICE The R amp S VSE can only be installed on the 64 Bit Version of Windows 7 2 1 Please Check if you have an FS K96 PC installed on your computer Parallel installation of FS K96 PC and R amp S VSE may cause any of the two applications to malfunction Installing the Software on your PC Performing the installation on your PC The R amp S VSE needs some additional software components to run properly The following components are needed e Microsoft NET Framework Version 3 5 e Microsoft NET Framework Version 4 0 VISA Virtual Instrument Software Architecture Install Microsoft NET Framework The R amp S VSE installer delivers the Microsoft NET Framework Version 3 5 and will try to install the Net 4 0 from the internet Install VISA It is necessary to install VISA Virtual Instrument Software Architecture to access instruments connected to the PC via IEEE or LAN bus Please use the National Instruments VISA The National Instrument VISA driver CD is supplied together with the R amp S FSPC You can also visit http www ni com visa to get the latest version for your operating system Installing VSE Please save the VSE Installer on your hard disc in order to Install the Software aT Release Notes 1177 5385 06 03 7 R amp S VSE Software Installation pren a 2 2 Installing Software Options
7. ements V 1 10 VSE K72 3GPP FDD WCDMA Measurements V 1 10 VSE K100 LTE FDD Measurements V 1 10 VSE K104 LTE TDD Measurements V 1 10 Spectrogram support in VSE K7 and IQ Analyzer V 1 10 Support for the following instruments RTO V 1 10 Full support for I Q File loading and recording Following File formats are supported iq tar iqw csv mat Supported Functions in Software V1 05 Version Function V1 05 VSE K7 Analog Demodulation V1 05 VSE K70 Vector Signal Analysis V1 05 Enhanced printing of result displays V1 05 IQ File Recoding V1 05 IQ File Playback V1 05 Support for the following instruments FSW FSV FSL FPS 1 2 Modified Functions The following table lists the modified functions and indicates the version in which the modification was carried out Modified functions of Software V1 10 Version Function V 1 10 VSE K70 Equalizer is now supported V 1 10 Creating a new channel copies the information about the connected instrument or file from the last active channel V 1 10 Connecting a new instrument will automatically choose this in all channels without an explicitly selected instrument V 1 10 The spectrum display is now part of the IQ Analyzer default displays V1 05 K70 Modified calculation of standard deviation for result summary 1 3 Improvement The following tables list the improvements and indicate si
8. ererewecnnienawen 7 2 1 Installing the Software on your PC ccceseceseeeeesteeeeseeeeeeeeesnaesnseeeeeseeesseseseeeeneeeeeees 7 2 2 Installing Software Options ccsscseeeeeeseeeeeeeseneeeenseeeeeneeesaeeeseeeeeeeeesseseseeesneeeeeee 8 2 2 1 Software options included in base software c cceeseceeeeeceeeeeeeeeeeeeeseeeeeseaeeeeaeeneeeeees 8 2 2 2 Other Firmware Options within the VSESetup exe File cceeeceeeeeeeeeeeeeeseeeeeeeees 8 2 2 3 Enabling Options by Entering Option Key Codes c cccccceceeeeeeeeeseeeeeeeeeeeeeaeeeeeeeees 8 3 Customer Support sicsntinstinetnsacauntinacienbinacivatansuiiocadnentanaietnlnupeanaininies 10 Release Notes 1177 5385 06 04 2 1 Current Version and History 1 1 New Functions The following table lists the new functions and indicates the version in which the new function was introduced New Functions in Software V1 11 Version Function V 1 11 VSE K102 LTE Advanced V 1 11 Added Terminator Setting to Network Settings Dialog V 1 11 Added Demo Files to Installation for the following Applications K6 Pulse Measurements K7 Analog Demodulation K70 Vector Signal Analysis K72 3GPP FDD WCDMA Measurements K100 LTE FDD Measurements K104 LTE TDD Measurements V1 11 Support for following FPS options B11 YIG Filter Bypass B28V Noise Source New Functions in Software V1 10 Version Function V 1 10 VSE K6 Pulse Measur
9. nce which version the issue could be observed Improvements of Software V1 11 V 1 10 K10x Saving lq tar File stored the wrong channel name within the file This issue is solved V 1 10 K70 Capture length was changed after recording was finished This issue is solved V 1 10 RF Attenuation Auto Mode was always set to manual after executing Auto level This issue is solved V 1 10 Disconnecting and reconnecting to an instrument resets all settings which instrument dependent This issue is solved V 1 10 Sweep stops when adding AF Spectrum display after loading an IQ File in K7 Analog Demodulation This issue is solved V 1 05 VSE K70 No warning is displayed for I Q Files that don t include enough symbols for the signal analysis This issue is solved Improvements of Software V1 10 SP1 V 1 10 Improvements for production Improvements of Software V1 10 V 1 05 VSE K70 Time trigger now supports setting the time interval V 1 05 Duplicating a Channel or loading a channel from a save set can lead to a channel which does not capture data This issue is solved V 1 05 Table results were always printed with a black background and white text This issue is solved V 1 05 The toolbars could be configured in a way which made it impossible to press any toolbar button This issue is solved V 1 05 Connecting an instrument via HiSlip worked unreliable This issue is solved V 1 05 The