Home
PLATFORM B2+ - User Manual
Contents
1. The Overload or under load indication will appear on the display as under OVERLOAD OF UNDER LOAD Adc The scale is programmed for 9 e steps plus scale capacity before it Indicates overload Hint to Get Accurate Reading The scale should be placed on a flat hard and leveled surfaced A slope in An action any direction will lead to inaccuracy in weight reading The scale should be installed in a steady environment i e free from wind Or rapid changes in temperature also the floor should be free from Vibrations If the scale is moved to a different environment with a large Temperature change one should give the scale 15 to 20 minutes to settle down Check weighing function This facility is used when a desired quantity of weight is to be packed within a weight Tolerance To set Press SET key The display will toggle between the last set value and HH higher limit setting Pressing SET key again will quit the entry mode To keyin the higher limit enter the required value by incrementing each digit with the ON Off and confirming each digit with the Enter key this display will toggle between the last set value and LL lower limit setting Pressing SET key again will quit the entry E G Kantawalla Pvt Ltd 5 www egkantawalla com PLATFORM B2 User Manual Eagle Mode To key in the lower limit enter the required value by Incrementing each digit with the key and confirming each digit with the
2. size follow it by placing the item desired to be Counted on to the pan and press the Enter key Display will show LOAD C Now press the Enter key again for confirmation After some time the SAP will go off from the display indicating that The scale has entered the counting mode If the unit weight is too small less than 0 8 of the scale division the display will show CSL Even if the mode are swapped the counting data is memorized by the scale and can be recalled later by entering the counting mode again lf you have already sampled one item and want to sample another item Then press Mode key till counting mode is displayed Now press set To enter setting mode Press On OFF to select the required sample size E G Kantawalla Pvt Ltd 6 www egkantawalla com C PLATFORM B2 User Manual agl Place the item to be counted and press the Enter key Display will show LOAD C Now Press the Enter key again for confirmation 5 Percentage Function i Percentage setting with load Place item whose percentage is to be set Press Mode key for selecting Percentage mode enunciator will light up and display will show LOAD P Press Enter key to confirm selection If the unit weight is too small less than 0 196 of full Capacity the display will show PSL Even if the modes are swapped the percentage data is memorized by the scale and can be recalled later by entering the percentage Mode again If you have
3. Enter key On Off Display will show the type buzzer Indication required for the Limit function The option available are IN OUT and NO When the stable reading is in between the lower limit and higher limit When OUT is selected the buzzer will sound when the stable reading is below The lower limit setting and above the higher limit setting Select the required option with the On Off key And confirm the selection with the Enter key If the Set lower limit is greater than the higher limit ErrLO will be displayed and scale Will be displayed and scale will prompt user to reenter the lower limit Pressing SET Key will quit entry mode Should the power be switched off the scale will still retain the check weighing value set as these are set in the non erasable memory of the scale The check weight function can only be cleared from the memory by setting both the Limits to zeros Even if the power is switched off the scale will still remain in the check Weighing function amp it will retain limit setting value sets as these are stored in the non Erasable memory of the scale Counting Function Press Mode key for selecting counting mode for counting parts having Equal weight Display will show SAP 10 Press the On Off key for selecting the sample size On pressing the ON OFF Key the display will sequence through modes S 0 and various sample Size available from S10 S20 S50 8100 and S200 After selecting the correct sample
4. G PLATFORM B2 User Manual Eagle User Manual PLATFORM B2 E G Kantawalla Pvt Ltd www egkantawalla com C PLATFORM B2 User Manual agl INDEX 1 Installation the scale 3 2 Introduction To The Scale 4 3 Operating Instruction 5 4 Cautions amp General Care 8 5 Service 9 6 Errors Message 10 E G Kantawalla Pvt Ltd 2 www egkantawalla com C PLATFORM B2 User Manual agl Chapter I Installation the Scale 1 Installation Unpack the platform scale carefully ensuring that no parts are lost Keep the Packing Material for future use Installation of the scale reguires a solid working surface free from heat radiation Vibration Excess Moisture draft and environmental features that may affect the Accuracy of the scale a Insert the four legs provided on the bottom frame mount the load cell on the b bottom Frame and on that fit the top frame carefully c Remove lower the transport lock bolts Set the overload bolts to 80 of the scale capacity d Place the S S pan on the top frame and fit the back rail Now mount the pipe on the threaded coupling and fit the indicator on the pipe connect load cell connector to the pipe Connect load cell connector to the indicator Caution Avoid excessive force while mounting the spider as the load cell Can get permanently damaged Plug the Adapter into a fully grounded power socket Ensure that the pin are fully inserted into s
5. On the identification plate The exact location of the scale An accurate description of the error Fault Weighing results Warranty card E G Kantawalla Pvt Ltd 9 www egkantawalla com C PLATFORM B2 User Manual agl Chapter VII Error message a ZEr H If on power on the Zero gt 20 F S the scale will alarm with a beep signal b OF If scale is overload the scale will alarm with a beep signal c LO Low voltage If the voltage If the voltage of the battery is low the weight display will display this message d UNSTA If on power on the scale is not stable the scale will display this message e ADC Ifthe adc overflows the scale will display this message f PSL Ifin percentage mode the sample is not enough the scale will display this message g SLAC if in counting mode the weight of unit sample is less than 50 of scale division the scale will display this message h CSL _ If in counting mode the weight of unit sample is less than 80 of the scale division the scale will display this message E G Kantawalla Pvt Ltd 10 www egkantawalla com
6. already set percentage of one item and want to set Percentage for another item then press mode key till percentage Mode is displayed Now press SET key to enter setting mode Place the item whose percentage is beset and Press the Enter key to Confirm selection ii Percentage setting without load To set percentage at a predetermined known weight RESET the scale and wait for countdown to complete and display to show 0 000 Now press the mode key for the display will show percentage mode Now Press the Unit key to enter the known weight in gram at which Percentage is to be set Enter the required weight by incrementing each digit with the ON Off key and confirming each digit with the Enter key Press Enter key again to confirm selection when digits stop blinking Now percentage mode will show 100 at the set weight E G Kantawalla Pvt Ltd 7 www egkantawalla com C PLATFORM B2 User Manual Eagle Chapter IV Caution Cleaning and General Care 1 Caution a Never leave a load on the scale for a long time as this may damage the scale b Always place load gently on the pan Dropping of the load on the pan may PERMANENTLY damage the scale C Never try to open the scale It may damage the mechanism And vital electronic Components installed There is no user serviceable Part installed inside the scale Maintenance if required shall be carried Out by authorized factory trained technicians Only d Never place th
7. e scale in rain or handle with wet hands e Never place the in high temperatures and wet places f Never hit the pan and overload the scale Don t use sample having weight more than scale s maximum Capacity 2 Cleaning and general care The scale should be cleaned regularly with soft cloth or Brush Stubbed grime Can be removed with damp cloth and if necessary mild detergent may be used b Do not use strong cleaning agents such as paint thinner acetone etc as these may Damage body o The scale should be cleaned in its normal operating position The Load Cell may get damage if the unit is tipped on its side Please ensure that the scale is discounted from the mains before Attempting cleaning IMPORTANT Spillage during weighing process should be removed Immediately E G Kantawalla Pvt Ltd 8 www egkantawalla com C PLATFORM B2 User Manual agl Chapter V Service If handled carefully the scale should not reguired maintenance of any kind for long Duration of time If a problem does occur they can be easily eliminated thanks to the modular design of the scale Contact the dealer who has sold you the scale He has been thoroughly trained at our works and will give expert advice and help in solving your problems So that the dealer has an clear picture of any error which might occurred please provide him with the following information Model Number On the identification plate Serial Number
8. mode 2 Keyboard Zero This key is used to zero out unwanted weight will Zero upto 496 of Scale capacity Tare If net weight is required amp a container is to be used to hold a sample Then place the empty container on the Platform and Press Tare key The scale will display 0 000 And Tare Enunciators will light up Negative Tare Weight is not allowed Tare can be cleared by pressing the Tare key Unit This key is used to toggle the display mode between Net kilogram mode amp Unit mode Mode This key used to select among weighing counting or percentage mode Cali This key is used for calibrating the scale Set Used for confirmation in setup ON OFF Used for selecting required value Enter Enter key used for confirmation E G Kantawalla Pvt Ltd 4 www egkantawalla com PLATFORM B2 User Manual Eagle Chapter lll Operating Instruction 1 3 Getting Started On Switching Power ON the Scale with On Off key will Display HELLO B2H124 And then will countdown from 9999 9 to 00000 Zero searching and Display will hold ON 00000 For 5 seconds Stability search and then come to zero with the Proper decimal point Gently place the object on the platform Display will start to increment It takes 2 to 3 second to get the final result for full loading waits for stable display Should the weight of the object be higher than the maximum or lower Than the minimum nominal value
9. ocket Avoid any mains outlet that has heavy eguipment such as computer Welding machine connected on the same line as this may produce heavy surges amp can produce errors in weight readings Clear the Platform and switch power with ON off key ON The scale will greet you With HELLO B2H124 and then count down 9999 9 to 0000 0 The Scale will initializes with And then wait for stability check until the display will show 0 00 0 00 e f as the Display will show The scale is now ready to use 2 Preparation a Please use separate power socket to avoid the interfacing of other Electrical appliances b Please don t put weight on the pan while the scale is being switched ON c Please place weight at the center of the pan and the weight should not Exceed the Maximum capacity of the scale d In order to get high precision result it s better to Turn ON the scale 10 to 15 minutes before use f Operating range of the scale is 52C 40 C E G Kantawalla Pvt Ltd 3 www egkantawalla com PLATFORM B2 User Manual Eagle Chapter II Introduction to the Scale 1 ooorps Display Enunciators Tare Indicates that Tare function is in use Zero Indicates that the Weight display is Zero Count Indicates that counting mode is in use Indicates that percentage mode is in use Kg Indicates that the scale is in kilogram kg weighing unit mode Unit Indicate that the scale is in unit