Home
A Guide to PID Control for Sous Vide Cookery
Contents
1. The PID controller can only switch power on or off it cannot reduce the voltage applied to the heater The controller recalculates the necessary power in cycles of 2 seconds default setting should not be changed and it switches power on for a fraction of the 2 seconds cycle e g to output 25 power is ON for 0 5 seconds and OFF for 1 5 seconds every 2 seconds cycle In other words output power is not controlled by reducing the voltage applied to the heater and thus reducing the current and wattage but by applying full power during a percentage time slice of each 2 seconds control cycle Output power applied to the heater is output power calculated by the PID algorithm multiplied by the Output power limit percentage thus simulating a heater with a lower nominal wattage What is the purpose of Output Power Limit e A well insulated high power cooker with high thermal inertia typically rice cookers may be difficult to tune appropriately without significant temperature overshoot Reducing output power may reduce overshoot and make tuning easier e Inthe 120V world where 1800W cookers draw 15A current reducing output power to 1200W helps reducing heat stress on the SousVideMagic controller during ramping up e You may want to purposely ramp up slowly for turbo conditioning tenderizing action of calpaines and cathepsines taking about four hours from room temperature to 55 C 131 F The table below shows what combos of water volume a
2. C Set Temperature P 10 C Proportional band is 60 C 70 C 80 C When Bath Temperature BT 50 C outside P band 100 heat is applied When BT 61 C 10 inside the P 90 heat is applied When BT 65 C 50 inside the P 50 heat is applied When BT 66 C 60 inside the P 40 heat is applied When BT 69 C 90 inside the P 10 heat is applied When BT 70 C PV SP 0 heat is applied When BT 72 C 20 above SP no heat is applied What P Proportional Band should I use for my cooker That will depend on your cooker s inherent thermodynamic characteristics kitchen environment your personal sous vide cooking style and the quantity mass and temperature of your sous vide pouches Generally if P is narrow single digits you get faster more responsive and more precise control with high gain power but with an increasing likelihood of overshooting your set temperature Narrow band means more power per degree of deviation from Set Temperature In a narrow band setting P the SousVideMagic SVM is elevated to work in a higher gain or higher amplification setting In this high gain condition the slightest amount of error deviation between the Bath Temperature BT and the Set Temperature SP can cause a large change in the power output of the SVM controller In other words a slight error i e difference between BT and SP will give your SVM high gain heat control as you get closer to your SP For example if
3. cause oscillation On the other hand if the I value is too high the unit may never come up to temperature fully but instead may stabilize at one or two degrees too low With I set to zero there is no reaction in the controller to integral differences the controller acts as a pure Proportional controller Counter intuitively nearly the same effect is obtained by specifying a very large value almost nothing happens On the other hand an I value of 1 will have an absolutely huge effect Logically the 0 value should be thought of as infinity but that would be difficult to enter on the digit selection The Derivative D value determines the reaction based on the rate at which the error has been changing The D value alters the speed at which the controller reacts to a sudden change in temperature disturbance This is useful to get the temperature back to Set Point more quickly after adding cold food to the bath It can be viewed as how quickly should I try to overcome this rapid change A small value in D will mean that the reaction of the controller will be to attempt to counteract the change for a shorter time If the D value is too high it will attempt to correct the temperature for a longer time so the outcome could be overshoot where as if it is too low it may take too long to compensate for the initial error Just to confuse matters further all of these outcomes are considered sepa
4. upper range of the P band the proportional function reduces output so much that additional output power must be contributed by the integral function PID tuning A balancing act A proportional integral derivative or PID controller performs much the same function as a thermostat but with a more elaborate algorithm for determining its output It looks at the current value of the error the integral of the error over a recent time interval and the current derivative of the error signal to determine not only how much of a correction to apply but for how long Those three quantities are each multiplied by a tuning constant P I or D and added together to produce the current controller output If the current error is large or the error has been sustained for some time or the error is changing rapidly the controller will attempt to make a large correction by generating a large output Conversely if the bath temperature variable has matched the setpoint for some time the controller will take no action This is how a constant temperature bath can be achieved As we have seen the SVM controller s power output varies from 0 to 100 as a result of the sum of Proportional P Integral I and Derivative D actions Obtaining good temperature stability despite possible disturbances is like riding a bicycle around a corner It requires a good balancing act Output Power Limit Level 3 parameter menu SLA What is the effect of power output limit
5. v9 428 S42 Aen au r4 451 67 473 as 400 Watt re am sa 485 4 r 97 oe 408 44 i a 1 st a ms 28 su 473 4 44 wy a4 yy 46 y 4 a A sa 4 9 42 n 42 x a 7 y x sy 1 2 44 8 705 s 2 6o 4 i rot a rx a n ro 104 r t 2 6 BY 7 751 ex 43 om 7874 or ays 94 7989 1 07 A e oe Dae 719 812 er ne f 104 242 82 r 23 f tt aa ae ify 7219 788 A na J r ih r t P f t 33 9 4 f vt s w4 4 1 449 79 x K 2 Oe 402 s 0 gt 4 4 A ran X t 762 448 wr ao T 0 10 30 30 40 5s 120 079 rary 961 at i Water volume liters E 1 ea yr ox rar Autotuning percentage Level 3 parameter menu SL8 What is the effect of Autotuning percentage With AT percentage 100 the default setting autotuning is performed at the SP Set Point temperature Lowering AT percentage lowers the temperature at which autotuning is performed thus yielding softer PID parameters What is the purpose of Autotuning percentage Example if your usual cooking temperature will be 55 C you perform AT with SP 55 C When cooking at lower temperatures e g 45 C your system might become unstable as heat loss which counteracts overshoot is lower at lower temperatures In this case you may perform AT at SP 55 C but with AT percentage set to 82 so AT will be performed at 45 C 55 C 82 yielding softer PID parameters which will result in a stable system at the lower temperature at the price of a slightly less reactive system a
6. V006 A Guide to PID Control for Sous Vide Cookery FRESH MEALS SOLUTIONS SousVideMagic PID Temperature Controller For Precision Sous Vide Cooking Model TM 1500D RELEASE 2 JULY 18 2011 Authored by Peter Black Australia Dr Peter Gruber Switzerland Frank Hsu Canada Robert Jueneman United States Send all comments to freshmeals gmail com Introduction I AM A BUSY CHEF AND I HAVE ENOUGH PROBLEMS JUST LOOKING UP ALL THE TEMPERATURE AND TIME TABLES TO COOK SOUS VIDE WHY SHOULD I BE BOTHERED WITH PID The most important aspect of sous vide cooking is the stability and accuracy of the constant temperature bath Our engineers with a given cooker will have no problem tuning SousVideMagic SVM to hold temperature within 0 1 C stability But not everyone is a process control engineer That s why we have given you the PID auto tuning tool to help adapting your SVM to work with your cooker to the best of its ability The beauty of the SousVideMagic approach is that there is no restriction as to the type of electric cookers you can pair with SVM provided they are not smart cookers with their own controls But there will be instances where the PID settings derived by Auto tune may not be refined enough for your liking Some understanding of PID will help you further adjust the PID settings for better sous vide performance meeting your personal preferences A PID temperature controller is essential
7. cess Value it is the current bath temperature BT and often known as controlled temperature SP Set Point it is constant bath temperature you want to achieve It is often known as Set Temperature ST Set Time it is the duration time in hh mm format for holding the Set Point SP before turning on the alarm in a normal case SVM 1500D is designed with food safety considerations so when timer is up the system will trigger an alarm but will continue to hold at the set temperature indefinitely P Proportional band_ C or F Range 0 and 1 to 50 from software version R5 up 0 0 and 0 1 to 50 0 If a P value is set and I and D 0 SVM becomes a Proportional controller Very often you will find that just by using P alone you can hold a constant temperature bath within 0 5 accuracy This is especially true with 1500D R5 and newer allowing decimal P values and with the FreshMealsMagic with minimal thermal inertia in conjunction with SousVidemagic s use of the thermistor sensing technology If P 0 irrespective of any value in I or D SVM becomes a simple on off temperature controller In practice this setting is never used because it just cannot control a constant temperature bath with enough precision for sous vide cooking Proportional band P is defined as the band measured in C or F from SP where heating action is applied in proportion to its deviation from set point SP For example SP 70
8. e to the knowledge of the sous vide cooking community in general and have not intended to make any financial gain from the publication of this document COPYRIGHT Copyright 2010 Fresh Meals Solutions All rights reserved This document may not be copied in part or full without express written permission from the publisher and authors
9. ermines the reaction to the current error In our application this refers to the number of degrees below the Set Point at which the power to the heating element will start to be reduced The effect of having proportional control is that instead of power to the heating element being applied continuously until the Set Point is reached it is slowly reduced from 100 power to zero as the measured temperature gets closer to the Set Point The Proportional value is measured in degrees Celsius or Fahrenheit and specifies the temperature at which the proportional decrease begins For example if the Set Point is 60 C and P 10 then power will be begin to be decreased beginning at 50 C To achieve the same effect when the unit is operating in the Fahrenheit mode it is necessary to multiply by 9 5 or 1 8 or P 18 The Integral I value determines the reaction based on the sum of recent errors and is measured in seconds What this means in practice is that the longer the temperature is below the Set Point and the further away from the Set Point it is the more power is applied to the heating element Basically the I value specifies how long the averaging period should be The effect of decreasing I is to cause the Controller to try to reduce the offset more quickly stronger I action However although with a low I value the offset will be reduced more quickly it can also have the effect of increasing the resulting overshoot and may even
10. food pouches are added to the controlled temperature bath The P band therefore must be adjusted according to conditions in and around the controlled temperature bath and other thermal dynamics such as lack of insulation and thermal conductivity which results in loss of heat at a certain rate In a well insulated cooker heat loss is low and the P band must be set wide In a condition where there may be considerable heat loss the P band can be set narrower What you want to adjust the controller for is an optimum point between stability and response time between holding a stable temperature and making fast corrections A typical example of closed loop PID tuning is given in a post in eGullet forum s sous vide topic on Jan 1 2011 see http egullet org p1777743 It shows that for a FreshMealsMagic in its uninsulated 18qt polycarbonate container with P 0 5 C or P 0 6 C and I 0 D 0 a very stable and extremely responsive system can be achieved with only minimal negative offset Note In software versions older than version 3 there was a special feature in the 1500D which can be used to help derive the optimal P band Because the 1500D always turns off the heat completely when it reaches the lower limit of the proportional band it allows you to test the latent heat and heat loss value of your chosen cooker You can observe how far the temperature will rise after the heating is stopped until PID controlled heat starts acting again If the
11. ge of the proportional band thus obviating the need to make otherwise adequate integral and or derivative weaker For example SP 55 C P 10 C I 900sec D 100sec So the proportional band would be 45 55 C With Ar 100 integral action would be active between 45 55 C With Ar 30 integral action would be allowed only in the upper 30 of the P band i e between 52 55 C What is the advantage of reducing Ar below 100 The ex factory default setting is Ar 50 This allows for strong integral and derivative settings for fast disturbance recovery without having to accept overshoot after ramping up or after a disturbance load adding cold food Summary Sometimes with an I value that adequately compensates for negative offset I action may be too strong especially in response to a disturbance temperature drop and lead to overshoot and eventually oscillation Instead of making I weaker increasing integral time Ar can be set to a value lower than 100 thus restricting the integration of negative offset to the upper range of the proportional band e g setting Ar 30 with a P band of 10 C and SP 55 C would allow integration of negative offset only between 52 55 C instead of 45 55 C i e the upper 30 of the P band In the lower range of the P Band output power allowed by the proportional function may be sufficient to counteract disturbance without the help of the integral function but in the
12. gral function adds up integrates temperature deviation from SP as the area under the curve With increasing integral the integral function adds more output to the output allowed by the proportional function to help in counteracting negative offset As long as the temperature is below the proportional band e g during ramping up from ambient temperature to SP the proportional function allows 100 output and the integral function increases output to more than 100 but more than 100 output is physically not possible and temperature rise cannot get faster as intended by the integral function So the integral term gets larger and larger it winds up and when SP has been reached and the output by the proportional term would be zero the integral term still creates output leading to temperature overshoot until the integral term has been unwound How is Integral windup avoided Modern PID controllers shut off integral action as long as the temperature is outside the proportional band This is called Ar or Anti reset windup or Anti integral windup Despite this Ar function integral windup may happen even at temperatures within the proportional band if integral time is set very short strong integral action and or if derivative action adds additional output during disturbance e g by adding a pouch with cold food The SousVideMagic 1500D has an advanced Ar function which allows to restrict integral action to the upper ran
13. he minimum and maximum temperature oscillation or stability Reset the thermometer s memory Drop an ice brick in the water and after another hour or more write down the minimum temperature disturbance dip and the maximum temperature post disturbance overshoot then reset the thermometer s memory again and repeat stability measurement as sometimes oscillation is initiated by disturbance It would be interesting to determine also the duration of the disturbance dip but this involves watching the display for maybe half an hour If all else fails you can try to persuade your teenaged son or daughter that this would make an excellent project for their next Science Fair Good Luck A sample spreadsheet for the evaluation of PID tuning results can be downloaded here http peter gruber gmxhome de SV TESTING PID SETTINGS htm LEGAL DISCLAIMER The materials herein and products mentioned in this document are offered for information purposes awareness and as non classified educational material These general concepts ideas and guidelines may or may not apply in some specific circumstances or situations and we do not give warranty for any workability in specific conditions pertaining to your personal or business situation Neither FMS nor the authors will be responsible for specific results from any recommendations or concepts nor for consequences thereof proven or otherwise The authors are volunteers whose sole aim is to contribut
14. ing D Derivative Time 0 3600 seconds To compensate for this sudden temperature drop we monitor the rate of temperature change over time of the bath temperature In other words derivative action is used to restore the change in bath temperature according to the rate of change It reduces the amplitude of undershooting It restores temperature stability faster Integral actions alone cannot correct this sudden disturbance in a responsive way you need extra help and it is called the Derivative action If the D is shortened restoring value becomes small and if the derivative time is made longer an excessive over correction can occur thus causing the bath temperature to oscillate and become unstable In classical control process theory the D value should be always about 25 of the I value For example if I 240 then D should be 60 i e 240 4 60 But in sous vide cooking using an insulated pot very often the D value will be much smaller than 25 of the I value Note SVM TM 1500D has a special feature so you don t need to add food at setpoint SP Timer is set to start only when SP is reached This feature allows you to add food earlier If you ramp up food with the bath you only need to use very small D values less than 50 thus making the PID tuning effort much easier Ar Integral Limit 0 100 aka Anti reset windup Integral is used synonymously with reset What is Integral windup reset windup The inte
15. ing strategy 1 Use the default PID settings first to cook some sample food pouches A 1 to 2 1 C to 2 C initial overshoot is quite acceptable and if the settings are appropriate it should soon settle to your desired set temperature 2 If the temperature stability is not adequate you should first try to use the PID settings suggested for some of the cookers listed in Table 1 Recommended PID Parameter Values in the SVM 1500D User Manual If you don t want to manually adjust the PID settings Auto Tune is the next thing you should try is In order to perform manual PID tuning or further refinement of the auto tune results an understanding of PID controller tuning is required How to best tune a PID controller depends upon how the process temperature bath responds to the controller s corrective efforts Processes that react instantly and predictably don t really require feedback control at all A car s headlights for example come on as soon as the driver hits the switch No subsequent corrections are required to achieve the desired illumination On the other hand the car s cruise controller cannot accelerate the car to the desired cruising speed so quickly Because of friction and the car s inertia there is always a delay between the time that the cruise controller activates the accelerator and the time that the car s speed reaches the set point A PID controller must be tuned to account for such lags Auto tuning Sou
16. ly a precision thermostat with a control mechanism to correct errors that cause a deviation from the desired temperature By comparison regular thermostats like those found in most domestic appliances are simply on off control devices For this explanation we assume that we are controlling an electrical resistive heating device With a simple on off control once the set temperature Set Point is reached power is cut to the heating element However because the heating element is still hot the temperature continues to rise until the latent heat of the element is dissipated When this happens the temperature starts to drop until a certain point somewhere below the Set Point is reached whereupon power is applied to the heating element again This has the effect of big swings overshoot followed by undershoot and sometimes a continuing cycle of oscillations in temperature around the Set Point For most kitchen applications or for the air conditioning in your house for that matter these swings do not make much difference and may not even be noticeable With sous vide SV cookery the variance of only 1 C or 2 C can have a noticeable impact on the finished product A PID Controller helps to overcome these swings Unlike a simple thermostat which has only the Set Point as its single parameter a PID controller involves three additional parameters These are the Proportional the Integral and Derivative values The Proportional P value det
17. n unique set of optimum PID parameters For the controller to heat with stability it must be programmed with the tuning parameters for the cooker currently being used When should the Controller be tuned If your cooker is not listed in the Table 1 of the 1500D User Manual of our pre selected cookers or the PID parameters we provide are not working to your liking you can use the auto tuning function to let the controller to determine the PID parameters automatically The auto tuning function it s often known as self tuning can automatically optimize the PID parameters for your chosen cooking system The auto tuning function will heat up your cooker then let it cool down It will repeat this heat cool cycle several times Based on the response time of the whole cooking system the controller will calculate and set the PID parameters for your cooker AT start AT calculation PV ON OFF Before using the auto tune function you must set the cooking equipment up in the exact configuration in which it will be used For example to tune a rice cooker place the sensor in the room temperature pot filled with water and plug the cooker into the controller If the cooker has its own thermostat or power control turn both as high as they will go If you think your cooker s heater is too powerful for the task on hand set the SVM controller to the appropriate power output level Level 3 s SLA parameter Turn the controller and cooker on a
18. nd then enter the desired set point temperature close to your normal cooking temperature range The amount of water in the pot should be what you would use normally Basically you must set up your cooking system to be as close to your actual cooking environment as possible If you cannot decide what power output level and set point temperature to use you should start with the default values 100 and 60 C 140 F respectively To activate auto tuning just enter the Level 2 menu s AL1 ATU PID setting mode Set ATU to 1 to start tuning process The Auto tune red LED indicator will be flashing throughout the whole tuning process You will see both the current water bath temperature and set temperature being displayed indicating that auto tuning is in progress When the Auto Tune indicator stops flashing this may take several hours depending on the thermodynamic characteristics of your cooker the auto tune is finished Now the newly calculated PID parameters are set and used for the system The new parameters will be maintained in the memory even when the power is off When auto tune is finished SVM will be automatically put in heat control mode you don t need to do anything Note You should always write down the current PID parameters before changing any parameters or perform auto tuning This way if something goes wrong you can always go back to your old PID parameters by re entering them manually The duration of auto tuning depend
19. nd wattage will achieve this As the minimum Output Power Limit setting is 20 this method will not easily work with rice cookers as they have too high a wattage in relation to their water volume With a 120V 1500W FreshMealsMagic it will work with a 28 30 liter beverage cooler by reducing power to 300W With a 400W stock pot or slow cooker power can be reduced to 80W allowing 8 liters to be ramped up in about 4 hours Please note that the table below does not take into account heat loss of a poorly insulated cooker as well as slower heating within the proportional band so real heating times may be somewhat longer Heating a water bath siowty trom ambient to 66 C ipectc heat of water t cally 1183 Wig 69 78 Went Heating tere men 22 C 5 Liters Vt gi och os mreng C Water bath ramping up time 22 C to 55 C Heating am 5 C pardesi Wate N Viw se G wo Wal 4 War 240 P 1 P Y x y f 7 ar 38 x f n zy lt 6 4 Th 277 D i b4 402 1 wo sy t 4 1 12 102 7X 1 28 48 4 2 184 E 13 j x aT a i 7 ya 7 oir ww 31 i i w as x 92 bbe 180 x wa 245 4 164 a j 7A 1 105 W 4t4 he 0 Q 7 216 40 rte w 2X 42 483 x 243 4 r25 oe 337 281 283 j r22 529 x 24 264 f 9 reyt 575 w y ti ra 508 wo cr y F f 4 42 61 ate Ms to ou 4 Z 80 Watt ie ee 4i JA amp f f y a oa po ot E 120 4 200 Watt 4 tew T 1 we We vo poe z ea 5 300 Watt a ya 182 21 4M 2 ane brs aa xe 360 Watt 12
20. netrate to the core of the steak One way to optimize these values is to use an external thermometer probe inserted in something that is the equivalent shape and thermal conductivity as the food you intend to cook Since you probably don t want to ruin a steak by putting it in the water without a bag you can cut a potato to the same thickness as the steak and insert the thermometer into the edge of the potato The thermal conductivity of the potato and a steak are close enough for most purposes Note Heat always flows into the center from the sides so it doesn t matter whether the steak is a small filet or a huge rib eye if they are both the same thickness and relatively flat they will both come up to temperature in the same amount of time Now if on the other hand you were cooking a baseball or a rolling pin that would be different matter Also note that the cooking time increases with the square of the thickness so a thick 50mm steak will take four times longer to come up to temperature as a thinner 25mm cut There are guidelines in this document to simplify the process of getting it right for your situation PID Control for Sous Vide Cookery SousVideMagic TM 1500D PID Temperature Controller If you are using SousVideMagic with a rice cooker the SVM s default PID settings 14F 800 40 or 8C 800 40 are generally adequate for most sous vide cooking situations Here is what we recommend you should do with your cooker PID tun
21. nts for Data Logging The various authors have tried several schemes for recording plotting and analyzing the data resulting from numerous PID optimization runs One thing that quickly becomes obvious is that manually recording data every 10 seconds or even once a minute for several hours is extremely tedious One way to solve that problem is with a data logging thermometer and a computer The data can be recorded over several hours then imported into a spreadsheet and plotted Unfortunately data logging thermometers with a resolution of 0 1 C or better are expensive they can cost as much as the SVM plus a commercial rice cooker Another approach that eliminates some of the tedium is to set up a digital camera that is equipped with an interval timer and take pictures of the Controller at a predefined interval and then enter that data manually Perhaps the simplest way to qualify PID settings without all the above mentioned complexity is with a digital thermometer resolution at least 0 1 F absolute accuracy is not crucial with minimum maximum memory and an ice brick blue ice of about 400 500g frozen to 20 C Start heating the bath at about 5 10 C below the set temperature and reset the thermometer s memory As soon as temperature has stabilized at set temperature write down the maximum temperature initial overshoot and the stabilized temperature Reset the thermometer s memory After an hour or more write down t
22. only a short time specified during which the system should recover a very strong action is called for This in turn may result in misestimating and a temperature overshoot may occur especially if there is a significant lag in the response time of the system Then once the Controller sees that the temperature has become too high it tries to compensate but it ends up reducing the power too much leading to an under temperature condition and the cycle begins all over again In the worst case the system is under damped and the oscillations continue without limit and may even become more violent For a given constant heater power output condition heat loss through the insulation will cause the actual temperature to be slightly less than it would be in a well insulated heated area This difference can be manually corrected with P it is like changing the position of the proportional band center point called offset so the result is the temperature you want to hold By adding Integral time action you will eliminate offset and converge to SP faster For example let s assume that you are able to hold constant temperature very well with your brand X cooker using P 10 C and I 600 seconds assuming D 00 Because you want to save energy and or you need a larger sous vide bath you decide to buy a well insulated commercial rice cooker with a 14L pot The old offset as expressed by I is likely to be too strong thus causing temperature overshoot
23. perature stability Increasing P gives your cooker less heating power Repeat until BT stabilizes below SP Set P at the average of the two previous values See example below If BT stabilized around the SP P is the band you may want to use For example Set Temperature 70 C and P 20 Set P 20 gt Temperature stabilizes around 62 C i e 8 C below SP P 10 Divide P by 2 gt Temperature stabilizes around 68 C P 5 Divide P by 2 gt Temperature oscillates around 70 C P 7 7 5 rounded Multiple 5 by 2 10 Average of 5 and 10 7 5 7 C is the established Proportional Band P of your cooker from this systematic process of trial and error You can further fine tune this P by 1 for better temperature stability at SP If the P band is wide double digits the temperature points at which SVM controller turns full on and the temperature at which it turns full off are quite far apart At this point the gain of the controller amplifier is set low It takes quite a change in the bath temperature to result in a change of the heater output This results in slow corrections of temperature There is little or no chance of overshooting and therefore the temperature is quite stable But although the temperature is relatively stable it may be off of the desired SP mark because of the gain not being high enough to keep up with changes in the environment around the controlled temperature bath This situation may occur when an unexpected blast of frozen
24. rately but when added together to adjust the heating element the outcome is often unpredictable and the process of optimizing the values sometimes becomes a trial and error effort SousVideMagic TM 1500D has a PID auto tune feature you might ask why the user needs to understand PID at all No matter how smart the auto tune software is written the results may not be perfect and further PID refinement by a human may be necessary for better temperature control to fit your particular goals and preferred cooking style For example if you customarily add the food to the SVM at the same time that you start the heating up the water then there will never be any sudden drop in the bath temperature and hence no reason to worry about a D value You can set D to 0 and then try to optimize the P and I values so that the water bath temperature stabilizes as quickly as possible but without any overshoot On the other hand you might control a SVM with an electrical timer so that it will turn on at 4 00 PM so it will be up to temperature before you come home from the office Then you might want to throw in a pre bagged frozen steak and you would like the steak to thaw and come up to the perfect sous vide internal temperature as quickly as possible and then stay there until your guests arrive and you are ready for dinner In that case a mild degree of overshoot in the temperature of the water bath may actually be beneficial because the heat still has to pe
25. s on how fast the system is responding to the heating and cooling cycle If the temperature of the cooker takes a long time to drop when heater is off auto tuning could be a very long tuning process This is especially true with a well insulated cooker The auto tuning should be able to tune most cookers available with fairly good result However the auto tune function cannot read minds It doesn t understand your habits or preferences or what you are cooking with the SVM Tempering chocolate at 82 F is quite different from cooking corn on the cob at 185 F It is therefore recommended that you should use the recommended default PID settings for a new cooker before trying auto tuning Using the auto tuned settings together with actual usage experiences you can further fine tune the PID parameters manually for a better result If you understand PID parameters well and are experienced with PID tuning you can combine both human intelligence and auto tune logic to derive the best PID settings for optimal performance in your particular environment Another important thing we like to stress here is that if you just don t want to learn PID we have a world wide network of very experienced SVM users who can help you with tips and guidelines and very often with their own proven PID settings Just email us freshmeals gmail com and we will spread the word Manually tuning the SousVideMagic Some process control terminology PV Pro
26. sVideMagic SVM s most powerful feature is its ability to regulate virtually any electric cooker with stable temperature control For stable temperature control the SVM needs to be set to match the thermal characteristics of the cooker being used That is it must be tuned to the cooker being used Tuning is the process that matches the control parameters P I and D of the SVM to the heating and heat loss characteristics of the cooker SVM is tuned to the cooker when its memory is programmed with values that effectively tell it how fast that particular cooker warms up and cools off and how efficiently it transfers heat For example consider the difference between a heat lamp and a hot plate When electricity is applied to a heat lamp it begins to heat instantaneously and when it s turned off it stops heating almost instantaneously In contrast a hot plate may take several minutes to begin heating when the electricity is applied and even longer to start cooling when electricity is turned off But to do this it must be programmed with the correct time constants which describe how fast the heater heats up when electricity is turned on and how fast it begins to cool when it s turned off These time constants are called the tuning parameters In some circumstances especially with high wattage heater well insulated cookers the SVM may also need to be set to attenuate the power output to reduce overshoot Every type of cooker has its ow
27. so you want to decrease the offset i e increase integral time by increasing the I value to slow down the heat output speed to prevent overshoot Asa rule of thumb it is probably better to start out with a large I value 3600 and see how long the system takes to come to a stable point and whether that stable point is actually at the Set Point If it is at the Set Point but it is taking an hour to get there you can cut the I value in half and try it again By continuing that process you will eventually come to a point where there is an inflection point i e where the temperature increases and shows a slight overshoot then decreases slightly then increases and finally settles out Depending on your tolerance for how fast you want the process to stabilize and how great an overshoot you are willing to tolerate will dictate the final I value Of course there are other ways to establish a constant temperature bath like increasing the P band or a combination of increasing or decreasing P and Integral time The problem is that if there is a sudden heat loss change disturbance and the system begins to lose heat faster then that changes the offset and you may not be there to manually correct it This is often the case for some sous vide cooks have the habit of adding cold or frozen food pouches to a constant temperature bath at SP This requires extra dynamic derivative heating power that is not allowed for by the original offset I sett
28. t the higher temperature For further details please see Application Tips in the 1500D User Manual Impact of Thermodynamic Properties of a cooker on PID Tuning Water Volume The higher the water volume the better temperature stability and the smaller the temperature drop from adding cold food at the price of slower ramping up Insulation Heat Loss Evaporation cooling may account for a significant percentage of total heat loss Evaporation should be avoided i e the bath covered especially in long time cooking it is easy to evaporate 5 liters in 48 hours at 55C Poor insulation leading to high heat loss has the advantage of easier PID tuning as higher heat loss counteracts overshoot faster at the price of some energy wasting Power Rating A high power rating has the advantage of fast ramping up and fast disturbance recovery at the price of more overshoot requiring a broader P band Thermal inertia of the heating system Heat content and heat conductivity of the heating element itself and the material between heating element and water are responsible for the thermal inertia of the heating system the greater the inertia the greater the overshoot requiring a broader proportional band to avoid overshoot Immersion heaters i e the heating element is in the water like the FreshMealsMagic or immersion circulators have minimal thermal inertia whereas rice cookers have greater thermal inertia and tendency to overshoot Hi
29. temperature rises by 3 degree as a rule of thumb you can set your P band by just doubling the temperature rise i e 3 degree rise implies P 6 if you want a fast heating system or trebling it P 9 if you want a slower system With a low heat loss cooker the time until heating resumes will be longer than with a high heat loss cooker This observation can be helpful in deriving the Integral value mentioned later Now we know about proportional control We also know about gain and stability There is one more consideration and that is the ability to hold a given temperature SP Due to heat loss BT may stabilize below the desired SP at a point within the P band corresponding to the percentile heat loss For example if your cooker s maximum heating power is 400W and you need 50W to compensate for the heat loss and keep BT stable then the percentile heat loss is 50 400 12 5 If your P band is 10 C then your BT will stabilize at SP 1 25 C In this situation you need I action to correct this offset undershoot I Integral Time 0 3600 seconds Integral time is used to eliminate offset from SP When the integral time is short the returning recovery speed to SP is accelerated however the cycle of oscillation is also accelerated and the control can become unstable and lead to possible overshoot Basically the I value specifies the time duration over which the errors should be eliminated If there is a significant error and
30. we narrow the Proportional band to 5 C SP 70 C Set Temperature P 5 C Proportional band is 65 C 70 C 75 C When BT 65 C outside P 100 heat is applied When BT 66 C 20 inside the P 80 heat is applied When BT 69 C 80 inside the P 20 heat is applied When BT 70 C PV SP 0 heat is applied When BT 72 C 40 above SP no heat is applied Now compare the two examples when BT 69 C at P 10 C SVM gives you 10 heat and at P 5 C SVM gives you 20 heat which is doubling the heat of SVM P 10 C when BT is 1 C from SP Under this situation you will have a greater chance of overshooting SP especially in a low heat loss situation e g using a well insulated commercial rice cooker That is why if the P is too narrow i e the SVM too sensitive even a slight temperature disturbance may cause temperature instability and possibly even a temperature oscillation around SP This temperature oscillation behavior can actually be very helpful in finding the best P for your cooker Finding the best P for your particular cooker 1 0 and D 0 by closed loop tuning 1 2 Set P X C for our type of cookers P 20 C isa good starting point If BT hovers below SP and stabilizes below SP divide X by 2 and observe the temperature stability Decreasing P gives your cooker more heating power Repeat until BT oscillates around SP If BT oscillates violently around the SP multiple X by 2 and observe tem