        2 - IT Alarm
         Contents
1.   Office 1 Room 17 1st floor 4     1  3  FIRE Det Zone 002 Det 02 15 10 28 07  g EDP room Room 21 1st floor       Fig  12  Example display for a fire alarm incl  detector information  example          In all  three fire signals were detected  The display shows the first  1   and the last signal   in this case 3   incl  group and detector information respectively  Pressing the cursor key scrolls the  display  and the next signal  2   is displayed     Time of this alarm message   Date of this alarm message     Additional text line     the additional text programmed for the triggered zone or detector will be displayed         Additional information text or parameter   additional text  Param AT      Significance of the display to  1  Fire     e First fire signal on 28 07 at 15 10 hours   e The detector No  02 in the zone No  02 signals Fire     e The additional text programmed for this zone  gt Office 1 Room 17 1st floor lt  provides information on the  location of the fire     e The display field  gt Info lt  shows that an information text has been programmed for this zone  which can be  accessed by pressing the corresponding function key     24 FB 798950  10 GB0   08 09       Fig  13  Cursor keys    Fire Alarm Control Panel IQ8Control C M    1  First   last message with the next higher priority    2  A next message with equal priority   additional messages    3  First   last message with the next lower priority    4  Prior message with equal priority    Further Displays   Messa
2.  2     At least one detector of the zone has malfunctioned     Inform customer maintenance service     A Switched off or malfunctioning zones will not transmit an alarm in the case of an event     14    FB 798950  10 GB0   08 09       Panel reset    Panel  reset       Audible Alarm off   silence    Audible  Alarm off   silent       Disconnect Master Box    Disconnect  Master Box       Fire Alarm Control Panel IQ8Control C M    All detected fire alarms  zones  displays and technical alarm signals  TAL  alarm  are cancelled and returned to normal condition     Access level 2  keyboard release with key  required     Access level 2     Activated alarm units can be silenced or enabled again by pressing the  button  toggle function     Depending on the programming of the fire alarm control panel  silenced  alarm units are automatically activated again upon every new event    The common display  gt Alarm off lt  visually indicates if alarms are  deactivated     Special function in access level 3     In access level 3  pressing of the button switches the connected alarm  units permanently off  They are not reactivated by subsequent events  The  common display  gt Alarm off lt  also lights up    When exiting access level 3  this function returns to the initial state     access level 2    The activating of the main alarm unit   the master box  MB  is switched on  or off  toggle function   Switch offs are displayed visually in the Common  display disconnection field     Switched off ala
3.  Trouble loop LINE TROUBLE  8 Transfer route switched on  loop  LINE ON  9 System trouble SYS TROUBLE  10 Disconnection DISCONNECTION  11 Disconnection loop LINE OFF  12 Trouble relay output TROUBLE  13 Switch off relay output O P OFF  14 Activate ACTIVATE  15 Testmode TEST          If the control panel is operated during the display  the corresponding function is carried out   The message with the highest priority reappears in the display automatically without the need to    press any additional buttons     26    FB 798950  10 GBO0   08 09    Fire Alarm Control Panel IQ8Control C M    4 1 3 Info text   additional text and parameter display    1  FIRE Det Zone  002 Det 02    Office 1 Room 17 1st floor 2  AN Access via stairway right   J Inform Mr  J  Smith  Tel  02137   99152        Fig  14  Info text display  example        Info Display of any programmed information text relating to the message in the alphanumeric  display  If information text exists  i e  has been programmed for this message  the menu  point Info is displayed  If  gt Info lt  text has not been programmed  the menu point  gt Info lt  is not  displayed       Param AT Display of the additional text programmed for the current message or a parameter  For a  parameter  a works programmed information text for the current message in the  alphanumeric display is shown  It is possible to switch between additional text parameter  display using the function key  If additional text has not been programmed  the menu poin
4.  case of the associated event     If a relay for which  gt inverse lt  activation has been programmed is disconnected  it will be deactivated  Control of  external equipment depends on the way in which it is connected to the NO NC contacts of the relay     case of an event     1 e The equipment connected to a disconnection control  e g  alarm devices  is not activated in the  e It is not possible to switch off the connected alarm unit     36 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M    4 5 3 Status ofa control    With this function  the current status  e g   gt Normal lt    gt Activated lt    gt Disconnection lt  or  gt Trouble lt  of the  corresponding control can be queried directly     Relay Status query   w 0       Fig  33  Status Relay 2  example     Press key    Operation Relay   0002  Status query  0001 message    Fig  34  Display status Relay 2       Relays may be set to  gt inverse lt  by means of customer data programming of the FACP IQ8Control  In this case   the relays will be activated in the normal state of the FACP and deactivated in case of the associated event     In normal operation of the FACP IQ8Control  relays programmed for  gt inverse lt  activation are indicated as     active        FB 798950 10 GB0   08 09 37    Fire Alarm Control Panel IQ8Control C M    4 6 Common display of the status messages    In the common display  gt Overview lt   all current messages such as  gt Fire lt    gt disconnection lt    gt Trouble lt  and  o
5.  condition of the control panel has been changed by an external influence     Displays     e The common display  gt disconnection lt   yellow LED  lights     e Possibly  a further display in the Common display disconnection field may be signalled  showing which  components have been switched off  e g   gt Relay or Master box  MB  lt      e The disconnection is reported in the display as a plaintext message     e A switched off zone is indicated on the single zone indicator units  optional  by a permanently lighting yellow  LED     Switched off zones  detectors and controls  AE  and other parts of the equipment will not signal an  alarm in the case of an event     3 6 Testmode    The yellow LED  gt Testmode lt  is permanently on  The  gt Testmode lt  mode of the control panel has been activated  for service and maintenance purposes     e The function of detectors zones is under inspection     A A zone in Testmode will not signal an alarm in the case of an event     FB 798950  10 GBO   08 09 21    Fire Alarm Control Panel IQ8Control C M    4 Operation    The following section describes the most important operating actions for a single FACP IQ8Control  If several  processors are connected in a network through the essernet   deviations from this description are possible  In  this case  please ask your specialised installer     The operation of an installed and operative fire alarm control panel may only be carried out by  authorised and trained personnel under observance of the s
6.  reset the Fire Alarm Control Panel   incl  all zones and alarm devices      Key switch  Lock unlock keyboard     The keys  gt Audible alarm off lt  and  gt  Panel reset  lt  can still be  operated when the keyboard is locked     FB 798950  10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    3 Operating status of the fire alarm control panel    The current operating status of the IQ8Control is shown on the operating panel  Six different operating  conditions are possible     3 1 Normal condition    The normal condition refers to an operative monitoring state of the control panel unchanged by external  influences     e The green LED  gt in Operation lt  lights   e No further displays or messages     e The key switch locks the operating panel keyboard     3 2 Fire   e The control panel is in alarm mode  i e  it is signalling a fire alarm    e The common display FIRE  red LED  lights    e The master box  MB  has been activated    e The internal control panel buzzer sounds    e External alarm devices  e g  acoustic alarm devices or control panel buzzers are activated    e The zone  which has detected the fire  is shown in the display with the programmed additional text     e The red LED of the corresponding zone s  lights in the single zone indicator units  optional   If several zones  signal a fire alarm  the red LED of the zone  which first detected the fire  blinks  initial alarm detection      e The red LED  gt Master box  MB  lt  lights when a master box for automat
7.  sli    lis  N  1s       ry    poy  A    Red LED is permanently on    Notify fire department    Red LED is permanently on    FB 798950  10 GBO0   08 09    Fire alarm     An external alarm is triggered    The fire and rescue services are alarmed via the connected  master box  If no master box  MFAB  is connected or if this could  not be activated  the LED  gt Call fire brigade lt  is also on     The fire releasing control equipment has been activated     The master box  MB  is activated and the intervention staff   e g  fire department  has been alarmed     The master box  MB  has malfunctioned or is switched off and  cannot be activated     Call the fire department immediately     Fire Alarm Control Panel IQ8Control C M                       gt        Fig  6 Common display pre alarm and LED with label field             A Pre alarm is signalled when an intelligent fire detector reaches the pre alarm level or when in a programmed  twin loop twin detector connection a loop or a detector have detected a fire alarm     The Pre alarm is automatically reset if no further signals are transmitted  The common display Pre alarm is  extinguished and any activated alarm devices are switched off  If further alarm signals occur  a fire alarm is  automatically initiated and the master box  MB  is activated  In case of a pre alarm  it is important that the  detector location and the cause of the alert are verified     Pre Alarm  Common display     RN DA ies At least one detector or zone is si
8. A EE ER E EEEE A E E E T 29  4 3 1 Switching on   resetting a Zone           uuursnsessssennsnnnnnnnnnnnnnnnnnnnnnnnnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ann 29   432 DISCOMMECEA ZONE saire ora E E aA EEEE A EEE E E EE A EESE E OTE ET 30   A  3S StaluS Ola ZOMG EAE E E E A A 31   AA  P L EE A E EATE 32  4 4 1 Switching on   resetting a detector                 2   24044440unnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 32   4  4 2  DIsConnect a Geloo iarere E EER EEE EE AE ETARE E AE AAEE RAEE EAE RRRA 33   4 4 3 Status of a detector                  20unnnn0nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnn 34   4 5     GONWOIS kreieren ee ageren Ferne devs sucess Tor era Ter rI ren Ei ede esters E AEAEE AA 35  4 5 1 Switching on a control                  220usnneennnnnnsnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 35   45 2 Disconnect a contol siio een nn re En ehe 36   4 5 32S tats Ola Keio  gli   e  IEREESPEREESTEFEITEFSEERRLEIT PELRETVERESSTETLPEHLETECRRISEER THRTTFTELSEREHRPERTEFELLETREH SER ESEHLBERRETERFTTSEER 37   4 6 Common display of the status messages            nnnnnnennnnnnnnnnnnnnennennnnnnnnnnnennnnnnnnnnnnennnennnennnnnnnnnnnnnanan 38  4 7  Delay and Verity stone cect ee ee ag Heng Weed teal erregen 39  AVA  DI  EA A tran Covet tea ena a he tes A ae eee ee a  bean MPa teeter 40   Arf DN CMe eaa bean tt toe Gt cuenta Aus eazeatct tesabt  aah ts ofc 205 tie e des int eaten bene 
9. ESSER    by Honeywell       Operation Instruction    Fire Alarm Control Panel IQ8Control C M    798950 10 GBO G 299044  Technical changes reserved     08 2009 G 205129       2009 Honeywell International Inc     Fire Alarm Control Panel IQ8Control C M       Intended purpose  This product must only be used for the applications outlined in the catalogue and the technical description  and in combination with external components and systems  which have been approved or recommended by  Esser by Honeywell     Warning  In order to ensure correct and safe operation of the product  all guidelines concerning its transport  storage   installation  and mounting must be observed  This includes the necessary care in operating the product     Safety relevant user information  This manual includes all information required for the proper use of the products described     The term    qualified personnel  in the context of the safety information included in this manual or on the  product itself designates     e project engineers who are familiar with the safety guidelines concerning fire alarm and extinguishing  systems     trained service engineers who are familiar with the components of fire alarm and extinguishing systems  and the information on their operation as included in this manual     trained installation or service personnel with the necessary qualification for carrying out repairs on fire  alarm and extinguishing systems or who are authorised to operate  ground and label electrical c
10. VKF Swiss  each Fire  Alarm Control Panel must be installed at an accessible place for the fire department and must be equipped with  the standardised Fire department operating and indicating panel  FBA     BB Steuerung  AH    Hauptmeider  06   BB testbetried    9       Fig  10  panel front with integrated Fire department operating and indicating panel  FBA        Fire department operating and indicating panel  FBA     Any other operating elements comply with the functionality of the panels standard front in  chapter 2 1        For additional versions of the operation panel front with a built in Fire Department Notifying and  Indication unit refer to the Fire systems catalogue     FB 798950 10 GBO   08 09 17    Fire Alarm Control Panel IQ8Control C M       Fire alarm  gt  red LED is permanently on    This LED is acommon fire indication  At least one fire message  has been detected     Trouble  gt  yellow LED is permanently on    This LED is a common trouble indication  At least one failure  message has been detected     A Switched off or malfunctioning zones will not transmit an alarm in the case of an event        Ad 1    y   IN    ZAJ             18    Fire alarm   red LED is permanently on  The remote alarm is activated and e g  the fire department is    notified  The LED lis until this message is manually resetted at  the panel     Audible alarm OFF    Pressing the button quits the started audible alarm of an fire or  trouble message     Panel reset    Press the button to
11. afety precautions and  if necessary  in    co operation with the relevant emergency services  e g  fire department      4 1 Function keys   selection menu      Overview   Service     Time func     Info   or param    add  text   gt      WD WH       Fig  11  Function keys   selection menu    Summary of the various menu options    The selection menu allows direct access to logically grouped menu options  When the keyboard is unlocked  up  to four menu options are constantly shown in the display  each of which can be selected using the function key  located below it     Status   Status display of current messages in order of significance     Summery  gt  Group display and number of the various types of message  such as  gt fire lt     gt trouble lt    gt disconnection lt  etc     Service   Transfer to the service level to operate the primary loop functions such as switching  primary loops  sensors etc  on off     22 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M       Installer  gt   Time funct   gt   Escape  gt     Acknowledge   gt   Function  gt     Rem Text   gt     Operating actions for the specialised installer for service and maintenance purposes    Individual password code required  if a code has been programmed      Entry of time date and the switching times of the Delay Verify function    Termination of the current input prompt without storing or executing the function   Acknowledge the selected menu point operation    Confirmation of the execution 
12. al alarm  modules  TAL  and the specially developed esserbus   transponder input output devices  These esserbus    transponders are loop devices with freely programmable inputs and outputs  for example for the activation and  monitoring of external devices such as display panels  alarm devices  door closers and other connected  equipment    Using the essernet   safety network  31 Fire Alarm Control Panel IQ8Control or other network subscribers such  as display and operating panels or alarm devices can be connected in a homogenous network  Operation of the  fire warning system  e g  switching off a zone  is possible from any fire alarm control panel or operating panel in  the essernet     Signals such as alarm  trouble  disconnection or other events are transferred to all subscribers in  the essernet   and can be accessed from any desired position  Data exchange can  according to the transfer  rate  be carried out either with a twisted pair or a LAN cable  The essernet   communications protocol  guarantees reliable data exchange even if a short or open circuit occurs in the network     Additional and updated Informations  Mm The described features  specifications and product related informations in this manual    correspond to the date of issue  refer to date on the front page  and may differ due to  modifications and or amended Standards and Regulations of the System design  Installation  and Commissioning     Updated informations and declaration of conformity are available f
13. ator     Housing door closed and key switch released     e In this access level  authorised and trained persons can perform operations and  query messages        Access level 3   Installer     Housing door open  key switch released and access code     e This access level allows operation  detailed status display and configuration of  the fire alarm control panel by trained and authorised specialists        Access level 4   System configuration        Housing door open  key switch released and service PC connected     e For programming of the FACP by service technicians and authorised specialists     Turning off individual alarm units   According to EN 54 2  it is prohibited to individually deactivate acoustic alarms  The control panel s  standard configuration therefore does not permit such operations or deactivation of an individual  line in case acoustic alarm units may be connected here    This configuration can be changed in the control panel programme     FB 798950  10 GBO0   08 09    Fire Alarm Control Panel IQ8Control C M    2 1 Key switch   enabling operation    The key switch can be used to lock the operating panel keyboard of the fire alarm control panel IQ8Control to  prevent unauthorised operation  In normal operating mode  the keyboard should be locked     Key switch in vertical position    locked    unlocked       Fig  2  Keyboard blocked    e The keyboard is blocked  The key can be removed     e The keys  gt Buzzer off lt    gt Function key F1 lt  and the Curso
14. c display function in the customer data programme of the control  panel  The label field    and or supplied label stickers can be used to label this customisable display function              gt  The assigned function is active   Yellow LED blinks    Alternative programming     J Y  5 A    a    a  gt  The assigned function is active   ZN    Yellow LED is permanently on    FB 798950  10 GBO0   08 09    11    Fire Alarm Control Panel IQ8Control C M       Fig  7  Common display TROUBLE    The common display Trouble is activated if at least one malfunction has been detected  The reason will be  shown on the alphanumeric display     Trouble  Common display     Ta Aika 2     ar   A component of the fire alarm control panel or a monitored relay  aay pN  gt  output such as an external alarm device or a master box has  malfunctioned   Yellow LED is permanently on  Operation  Sl Mi  Ay RS en The power supply  battery or mains voltage  is connected  The    fire alarm control panel is in an operative condition   Green LED is permanently on    CPU failure  solid The fire alarm control panel is only partially operative due to a  Ey se malfunction of the control panel functions  Display or operation of  rs the control panel is no longer possible  Exception  Key Buzzer  off    Yellow LED is permanently on  gt     The activating of the master box  MB  and the LED    gt Master box lt   MB  and  gt Notify fire department lt  is still operative  in the CPU failure mode of the control panel in th
15. connect can be performed     44 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M    5 2 Sensor functions  zone detector     Using this function  it is possible to switch off sensors in zones or in individual fire detectors in an analog loop     By entering the zone and detector number  individual sensors can be switched off in each single intelligent  detector  If only the zone number is entered  detector number   0   the desired sensor switch off is performed  for all intelligent detectors in this zone     If sensors have already been switched off in individual intelligent detectors in this zone  the message   gt Switch on off not permissible lt  appears  All sensors must first be switched on in this zone before the desired  sensors can be switched off     See also Sensor function loop      Sensors  loop   Primary loop    i 1 O  Sensor off  2 Ol Sensor off    Detector E 3 I G Sensor off  4 Sensors on            Fig  45  Sensor function related to zones detectors    It is only possible to switch off sensors with the OH  OHG and OHI intelligent fire detectors   If intelligent fire detectors are installed together with single criteria detectors  detectors with just  one sensor  on an analog loop  only the sensors on the intelligent detectors are switched off    If a switch off has already been performed  e g  the sensors of a zone have been switched off  this    zone or the entire analog loop cannot be additionally switched off  It is possible to switch off 
16. e alarm occurs during the active function  gt Delay lt   the master box  MB  is only activated after the expiry of  the programmed delay time  max  600 seconds   If the key  gt Verify lt  is pressed during the delay time  the delay  of the activating of the master box is extended by the verification time programmed in the customer data  max   600 seconds   The cause of the alarm can be verified in this period     After the expiry of the delay and the verification times  the master box  MB  is activated  A automatically if the alarm state has not been cancelled and the activation of the master box    inhibited by pressing the  gt panel reset lt  key     Time func  Time Date  Time   10 42  Date   Tu  02 06 99    Delay on   J     off           HE ee      Fig  37  Entering a switching point for the delay time       If a switching time for the function  gt Delay Verify lt  has been programmed in the customer data by the installer of  the fire alarm system  the first switch on time and the first switch off time is accepted as the valid switching  time when an additional switching time is entered under this menu point  gt Time functions lt   Exceptional days can  be specified in the customer data programming on which the automatic  i e  delay Verify times programmed by  the installer will not take effect     Example    Customer data programming  Switch on 06 30  switch off 21 30  Operator s entry under this menu point  Switch on 10 00  switch off 15 00  Valid switching time  Switch 
17. e case of a fire  alarm     Power supply    Ashi    N    1  ys    N  gt  The power supply  battery or mains voltage  is out of order     A  7    SS    Yellow LED is permanently on    In cases of malfunction or emergency operation  correct functioning of the FACP is no longer  ensured  Inform customer maintenance service     12 FB 798950  10 GB0   08 09          Disconnection                Relay Outputs          Master Box                Testmode                Fig  8  Common display Disconnection    Fire Alarm Control Panel IQ8Control C M    The common display  gt Disconnection lt  indicates that at least one output  input  or other component of the FACP  has been disconnected  The disconnection will also be shown on the alphanumeric display     Disconnection  common display     Re ITA       Dsoorecioy     77 yy       Yellow LED is permanently on    Relay Outputs    On  A  a    al  u     gt      a             Yellow LED is permanently on    Master box  MB   A             Yellow LED blinks    aly    a    l  z  ZN    YA I     Yellow LED is permanently on    Testmode       li    er  N    al  s       ry     S  4a    Yellow LED lights    At least one input output e g  a zone or relay has been switched  off     At least one relay output such as an internal control panel relay  or the control of an esserbus   transponder has been switched  off     Access level 3     Activation of the master box is automatically prevented by the  opened tamper switch  no deactivation    In case of a
18. e cursor keys and press the  gt Function lt  key    In the case of an input error  pressing the Zone key can erase the display and the primary loop number can be  re entered     A Disconnected fire detectors and call points will not activate an alarm in the case of an event     46 FB 798950  10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    Slot and associated primary loop number    Individual modules in the panel can be switched on off via the panel keyboard with the internal  four digit  primary loop number or can also be programmed with the customer data editor  The internal primary loop  number is made up from the panel number  the slot and the module number     Example  FACP IQ8Control  Panel number 01        Fig  47  Example  FACP IQ8Control    01    X u     Slot number of the Basic   Field device  or Extension module    Slot number  Basic module  Nr  1  Basic module slot 1  Nr 2  Basic module slot 2  Nr  3     only FACP IQ8Control M     FACP Number  Stand alone panel   01  Network panel   01 31    FB 798950 10 GBO   08 09 47    ESSER          by Honeywell  Novar GmbH a Honeywell Company C      Dieselstra  e 2  D 41469 Neuss Telefon   49  0  21 37   17 0 Verwaltung 0786  Internet  www esser systems de  49  0  21 37   17 600 KBC Novar GmbH  a L D 41400 Neuse  E Mail  info esser systems de Telefax   49  0  21 37   17 286 eeo       
19. ed individually     Please note that the zone number has to be entered ahead of the detector number     Zone Detector Status query      0 7 0  0 0 7 P    Fig  27  Status zone 2   detector 12  example     Press key    Operation Zone   0002 Det   0012  Status  normal    Fig  28  Display Status zone 2   detector 12       34 FB 798950  10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    4 5 Controls    4 5 1 Switching on a control    With the switch on  a previously switched off control  relay  open collector output  is switched back on   In case of an event  the switched on output will be controlled in accordance with the programmed control  conditions     Relay      0      Fig  29  Switching on Relay 2  example     Press key    Operation    Relay  2 On  in progress    Fig  30  Display switching on Relay 2       FB 798950 10 GB0   08 09 35    Fire Alarm Control Panel IQ8Control C M    4 5 2 Disconnect a control    With the disconnection  a control  relay  open collector  is disconnected  In addition to the plaintext message in  the display  the Disconnection of the control is indicated optically in the Common display disconnect field          0      Press key    Fig  31  Disconnect Relay 2  example     Operation    Relay  2 Off  in progress    Fig  32  Display disconnect Relay 2       Relays may be set to  gt inverse lt  by means of customer data programming of the IQ8Control  In this case  the  relays will be activated in the normal state of the FACP and deactivated in
20. ements are made on a fire warning system  whether in small commercial facilities or  in industrial plants  the Fire Alarm Control Panel IQ8Control transforms safety techniques and economy into  practical reality  The modular design with different micro modules and individual extension concepts allow the  FACP IQ8Control to be easily adapted to special requirements    The FACP IQ8Control represents the most modern standard of fire warning technology  A reliable fire warning  facility is guaranteed by the application of  intelligent  fire detectors connected in an analog loop  which is  tolerant to short and open circuits     In this analog loop   the esserbus     esserbus   PLus   up to 127 loop devices each capable of being  configured into 127 individual zones can be connected with an overall cable length of up to  3 5 kilometres  The esserbus   is a two wire line supplied and monitored at both ends in ring topology  The Fire  Alarm Control Panel IQ8Control automatically registers the wiring of the analog loop and determines the logical  addresses of the individual loop devices  A separate adjustment of the addresses of the individual loop devices  is unnecessary  Fire alarm panels with esserbus   PLus analog loop provide the direct connection of  addressable notification appliances  e g  sounder to the loop  There is no need of an auxiliary power for these  loop devices    Subscribers in the esserbus   are automatic intelligent fire detectors  manual call points and technic
21. ges    For your information  the following additional messages  if existing  are shown in the alphanumeric display     MB disconnected  gt     MB trouble  gt   Acoustic trouble  gt   Acoustic  gt     disconnected     Revision active  gt     FB 798950  10 GB0   08 09    When the activation of at least one master box  MB  for the warning of the fire  department has been switched off  e g  by enablement of the keyboard     When at least one master box  MB  has malfunctioned     When at least one acoustic alarm device has malfunctioned     When at least one acoustic alarm device has been disconnected     When the fire alarm control panel has been switched to revision on the fire  department operating panel     25    Fire Alarm Control Panel IQ8Control C M    4 1 2 Display priority of the messages in the display    Display priority    The first and last messages with the highest current priority are shown in the alphanumeric display of the FACP  IQ8Control respectively  If several messages with equal priority are imminent  these can be queried by pressing    the Cursor keys     In priority level 1  only groups with a fire message are displayed for increased clarity     The corresponding detectors  FIRE D  are displayed in priority level 2 messages                                               Priority stage   Condition Display  1 Fire alarm  zone  FIRE  2 Fire  fire detector details  FIRE Det  3 Fire loop FIRE  4 Technical alarm T ALARM  5 Pre alarm PRE ALARM  6 Trouble TROUBLE  7
22. gnalling the pre alarm  TIPPEN     ER   gt  The activated detector or the activated zone is indicated on the    alphanumeric display   Red LED is permanently on p 2     The internal central buzzer also sounds     Control actions assigned to this event by means of customer data programming  e g  relay outputs for activating  internal signalling devices or evacuation signals will be executed     On pre alarm  the master box for alarming the emergency services will not be activated     10 FB 798950 10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    Delay  ur An on off switching interval has been programmed for the delay  Se function   Th ro    During this time  the activating of the master box  MB  due to a  Yellow LED is permanently on     gt  fire alarm is automatically delayed by the delay time  programmed in the customer database        An alarm signal has been detected during the active delay time       gt     The programmed delay time has been initiated   Yellow LED blinks    The master box is activated after expiry of this time     Verify    di    Cod  N         x  I    The key  gt Verify lt  has activated the function Verify     Se  Ar    T The programmed Verify time for the Verify of the cause of the  5 alarm is running   Yellow LED is permanently on    The master box is only activated after the expiry of the Verify  time     The function  gt Delay Verify lt  is described in chapter 4 7     LED with label field       This LED can be assigned a building specifi
23. hen a date is entered  gt DD MM YY lt   the day of the week  Mo  Tu  We     is  automatically calculated     Escape   Exits the menu point without storing the changes inputs    Function   gt  The numeric values shown in the display are stored    Entering times for the function  gt Delay Verify lt  refer to chapter 4 7        Without the need to press any additional buttons  the display switches back automatically to the  last menu point without storing the changes inputs     28 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M  4 3 Zones  4 3 1 Switching on   resetting a zone    With switch on reset  a zone  which has been switched off  incl  all fire alarms   is switched into the operative  status or an operative zone is reset and any imminent messages such as  gt Fire or Trouble lt  are deleted     Zone      0      Fig  16  Switching on   resetting a zone 4  example     Press key    Operation    Zone  On  Detector  0 in progress    Fig  17  Display switching on zone 4       FB 798950 10 GB0   08 09 29    Fire Alarm Control Panel IQ8Control C M    4 3 2 Disconnect a zone    With the disconnection  the corresponding zone  incl  all fire alarms  is disconnected   The zone is selected by means of the corresponding zone number          0      Press key    Fig  18  Switching off   resetting a zone 4  example     Operation    Zone  Off  Detector  0 in progress    Fig  19  Display switching off zone 4       In addition to the message on the display  the Disconnec
24. ic transmission of the alarm is  connected and the fire department has been informed     e Possibly  the red LED  gt Notify fire department lt  may light  The fire department has not been informed via the  master box     e Call the fire department immediately     FB 798950  10 GBO0   08 09 19    Fire Alarm Control Panel IQ8Control C M    3 3 Trouble   The common display TROUBLE  yellow LED  lights and the control panel buzzer sounds intermittently   e Atleast one control panel function has failed    e Amessage is shown in the display describing the failure cause     e The yellow LED of the zone in which the malfunction has possibly occurred blinks on the single zone  indicator units  optional      Zones relay loops or inputs outputs will not signal an alarm in the case of an event   Inform customer maintenance service     3 4 CPU failure   The fire alarm control panel is only partially operative    e No messages on the alphanumeric display    e No evaluation of information    e No activation of external equipment such as alarm sounders     e The master box and the  gt Master box  MB  lt  LED and Notify fire department will be activated even in the  control panel CPU failure mode     A comprehensive operation in a CPU failure mode  emergency operation  or system fault of the fire  alarm control panel is no longer provided  Call customer maintenance service immediately     20 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M    3 5 Disconnection    The normal
25. ice    in the status level    Service  1 Primary loop function  2 Sensor function  loop     3 Sensor function  zone   det      Fig  43  Display in the service level       The following operations and switch offs can be carried out in the service level on the fire alarm control panel  without entering an authorisation code     1 Sensor function  loop   refer to chapter 5 1 2     2 Sensor function  zone detector   refer to chapter 5 1 3     e The service level 3  Installer  is protected from unauthorised access by means of an access  code  Any operation of the FACP may only be carried out by authorised and trained persons  under observance of the safety precautions and  if necessary  in cooperation with the  emergency services  e g  fire department      e Option 1  primary loop function  can be selected in access level 3  refer to chapter 5 3     42 FB 798950  10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M       5 1 Sensor functions  loop     Using this function  detector sensors of the intelligent fire detector such as all O sensors  Optical   photoelectric  sensor  or all   sensors  l   ionisation smoke sensors  or in OHG intelligent detectors the OG sensor  combination or in OHI intelligent detectors the Ol sensor combination in an analog loop can be switched off     If  for example  OHI intelligent detectors are disconnected with the function  gt Ol sensors off lt   only the third    sensor   the H sensor  heat sensor    remains active  Disconnecting the heat sen
26. ig  23  Switching on zone 2  detector 12  example     Press key    Operation    Zone  2 on  Detector  12 in progress    Fig  24 Display switching on zone 2   detector 12       32 FB 798950 10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    4 4 2 Disconnect a detector    With the disconnection  an individual detector of the selected zone is disconnected  In addition to the message  on the display  the disconnection of the detector is indicated optically in the Common display Disconnect field     Individual detectors within a zone can only be disconnected if addressable series 9100  9200 and IQ8Quad    detectors are used   Series 9000 standard fire detectors cannot be disconnected individually     Please note that the zone number has to be entered ahead of the detector number          0   0 0      Press key  Fig  25  Disconnect zone 2  detector 12  example     Operation    Zone  2 off  Detector  12 in progress    Fig  26  Display disconnect zone 2   detector 12       A A disconnected detector will not signal an alarm in the case of an event     FB 798950 10 GB0   08 09 33    Fire Alarm Control Panel IQ8Control C M    4 4 3 Status of a detector    With this function  the current status  e g   gt Normal lt    gt Alarm lt  and  gt Trouble lt   of the corresponding detector can  be queried directly     Individual status query within a zone is only possible if addressable series 9100  9200 and IQ8Quad detectors  are used  Series 9000 standard fire detectors cannot be queri
27. ircuits  and or safety equipment systems     Safety warnings  The following information is given in the interest of your personal safety and to prevent damage to the  product described in this manual and all equipment connected to it     Safety information and warnings for the prevention of dangers putting at risk the life and health of user and  maintenance personnel as well as causing damage to the equipment itself are marked by the following  pictograms  Within the context of this manual  these pictograms have the following meanings     Warning sign  Designates risks for man and or machine  Non compliance will create risks to man and or  machine  The level of risk is indicated by the word of warning     Important information on a topic or a procedure and other important information     Observe configuration and commissioning information in accordance to the national and local  requirements     o a  gt     Dismantling  In accordance with Directive 2002 96 EG  WEEE   after being dismantled  electrical and  electronic equipment is taken back by the manufacturer for proper disposal     1     2 FB 798950  10 GBO0   08 09    Fire Alarm Control Panel IQ8Control C M    1 GeNelal vad  ditedia dda ada aan EEE ina da aaveatn Ava dled ea ded a iad ad aid aden 4  2 General View     Operating panel front  from 08   2009          csseeseesscesecesesesceeecaeeeseeeeeseseeeeeeeeesecaeeaeecaneeasaeetaseeaeataces 5  2 1 Key switch   enabling operation                   ernnsnnsnnnnnnnnnnnnnn
28. lay standard or 1   4 VGA display          Menu         Function key   display          Cursor key     other messages   information    All received signals such as fire  trouble or switch off are shown in the alphanumeric display in alphanumeric  form  8 lines  40 characters per line      Keyboard    By means of the key switch  the keyboard is unlocked for operation  With these keys  it is possible to control  panel functions such as switching zones and detectors on and off     Function keys    With the four function keys  the menu options positioned above them in the alphanumeric display are selected   Depending on the current state of the fire alarm control panel or the operation level  differing menu options are  shown in the display     8 FB 798950 10 GB0   08 09       Fig  5  Common display fire    Fire Alarm Control Panel IQ8Control C M    The common display  gt Fire lt  is activated if at least one fire alarm has been detected  The originating detector or  zone will be shown on the alphanumeric display     If evacuation plans or guidelines exist for cases of fire alarm  these plans have to be followed and  the premises have to be evacuated  if necessary  Make sure to inform yourself well in advance    about existing escape routes and required measures in case of a fire     Fire  Common display     l  ll         Ele         ae  spp  we    Red LED is permanently on    Fire Releasing System    Su th     lr    Zr    A    N    Red LED is permanently on    Master box  MB    
29. n event  no  automatic activation takes place  This condition is only changed  by closing of the tamper switch  no button function      Access level 2     The master box  MB  is switched off  e g  for servicing  by  enablement of the keyboard with the key switch     A component of the control panel  e g  zone  has been set to  Testmode for servicing and maintenance work     A zone in Testmode will not transmit an alarm in the case of an event     A A switched off master box will not transmit an alarm signal in the case of an event     FB 798950 10 GB0   08 09    13    Fire Alarm Control Panel IQ8Control C M               nn E  u     ren ii  mm              Fig  9  Single zone indicator units  GEA     Optical displays  LED  for a total of 64 zones may be integrated into the control panel of the IQ8Control  Fire is  signalled by a red LED  A yellow LED signals malfunctions and disconnections  There is a labelling field for  each zone  which can be marked with the name of the zone or of the area monitored by this group of detectors     Fire    AA    A      a  AN    Red LED is permanently on    A              Red LED blinks    Disconnection   Trouble  6  N    Yellow LED is permanently on    di         Y            Yellow LED blinks    At least one detector and   or one manual call point in the zone is  signalling a fire alarm     For the zone  which first signalled the fire alarm  initial alarm  detection      The zone is switched off     Switching zones on off refer to chapter 4
30. nnnnnnnnnnnnnnnnnnnnnnnnannnannnnnnnannnnnnnnnannnannnnnnnnnnnann 7  2 2 Function of the display and operating elements                   snsssnnnnnnnnennnnnnnnnnnnennnnnnnennennnnnnnnnnnennnnnn 8  2 3 Operating panel with FBA CB  Part No  786207   nnne ennn nnnm 17   3 Operating status of the fire alarm control panel               snnnnnsnennnnnnnsnnnsnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnen 19  3 1 Normal Condon  iin Siitian denen ana Ina dildahdla ani dilaniwan 19  32 Freuen aa a e FIR PLENUIVETERORFEDEIEIFELEFENERTEPEIEUSTRTEFENFIRERSFLFEROINEEIFEREUFEFEFERTEEREHEFEIDFEFERPRERR PUR 19  3 3  MOUDE ar r EA a a a e EE id A A ERT 20  Jar  EPRUTAl  re Arterien er arte e a a a Sas Reverend NA A 20  3 5       DISCONNECTION Aaa a AAAA OA OA a a EA AA 21  36   Testimode    2 228 E E ee a Bea ela ras a SE 21   4 OPBErAllON nn E E E E r EE 22  4 1 Function keys   selection menu          eececceccseceseeeseseseseseseseeeeeeseeeaeecaeaceeasseacaessaeseseteaeceecetesaeaneceeeeaeeeneesaeataeens 22  4 1 1 Display   display control                 0rs44srnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnn 24   4 1 2 Display priority of the messages in the display                   20rsn40ensnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnannn 26   4 1 3 Info text   additional text and parameter display                       240rsnnsnnnsnnnnnnnnnnnnnnnnnnnnnnnnn mann 27   42  Entening tume daters       zur  heii uta cis near inte ate hin REN 28   7  Ur E 012  E N NE EE 
31. of the previously selected function    Query of the additional text display  Remote text  of other fire alarm control panels in  the essernet   network  If an event has been detected by a fire alarm control panel in    the essernet    the additional text from the activated fire alarm control panel can be  displayed by the remote text function on another fire alarm control panel     Information and additional text    Info      Param AT   gt     Display of any programmed information text relating to the message in the  alphanumeric display  If information text exists  i e  has been programmed for this  message  the menu point  gt Info lt  is displayed  If info text has not been programmed   the menu point Info is not displayed     Display of the additional text programmed for the current message or a parameter  For  a parameter  a works programmed information text for the current message in the  alphanumeric display is shown  It is possible to switch from additional text parameter  display using the function key  If additional text has not been programmed  the menu  point  gt Add  text lt  is not displayed     text shows the information text     If information or additional text has been programmed for a message  the additional text   Param AT  is always displayed first  Pushing the function key during the display of the additional    FB 798950  10 GBO   08 09    23    Fire Alarm Control Panel IQ8Control C M    4 1 1 Display   display control    L 1  FIRE Det Zone 002 Det  02  
32. on 06 30  switch off 15 00    FB 798950 10 GB0   08 09 39    Fire Alarm Control Panel IQ8Control C M    4 7 1 Delay    By pressing the  gt Delay lt  key  the function  gt Delay lt  is started or ended manually  toggle function   The activated  delay function is indicated on the operating panel by the continuously illuminated yellow LED  gt Delay lt      Delay       Fig  38  Delay key    If a fire alarm occurs when the delay function is activated  the activation of the master box  MB  is delayed by  the delay time programmed in the customer data  max  600 seconds   The blinking yellow LED indicates the  initiated delay time in the operating panel     4 7 2 Verify    If the delay time has been started due to a fire alarm  the activation of the master box can be delayed  additionally to the delay time  max  600 seconds  by the verification time  max  600 seconds  for the  gt Verify lt  of  the cause of the alarm by pressing this key     Verify    Fig  39  Verify key              For the  gt Delay lt  and  gt Verify lt  functions  pay attention to the guidelines of VdS Schadenverh  tung  GmbH     4 8 Alarm counter    Differentiated display of the detected alarm signals from fire and technical alarm zones for this individual fire  alarm control panel and the aggregate value of all other fire alarm control panels interconnected in the  essernet      Alarm counter 10 24 10 05    Fire alarm   Sum   50  Tech  alarm   Sum 2    Fig  40  Display alarm counter       Example display    Thi
33. or comparison on the  www esser systems de homepage     esserbus   and essernet   are registered trademarks in Germany     4 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M    front  from 08   2009     2 General View   Operating panel    ie          2  3     5 6           ee  2    EEE       45 04 49 42    Fig  1  General view of the display and operating elements       Single zone indicator unit  GEA  option   2  Common display FIRE    3  Common display PRE ALARM    4  LED with label field    5  Common display TROUBLE   6 Common display DISCONNECTION  7 Alphanumeric display    8  Function keys     display                             9  Key switch       10 Cursor keys     additional messages   information       nn    an Function keys     general       12  Function keys     commands 2  43 Keyboard 0 9    4  Opening for Programming via Serice PC  Connector must locked with dummy plug for ESD protection    Function keys     commands 1             A    o         FB 798950 10 GB0   08 09 5    Fire Alarm Control Panel IQ8Control C M       Access levels    When enabling the operating panel for operation using the key switch and the access code for the relevant  access authorisation  it can be operated at four different access levels     Access level 1    Housing door closed and key switch locked    e Only the buttons  gt Buzzer off lt    gt Function key Fi lt  and the Cursor keys for  displaying the messages in the display can be used        Access level 2   Oper
34. other  zones of this analog loop in which detectors or sensors have not been switched off     A Deactivated groups and detectors do not register an alarm if an event occurs     FB 798950 10 GBO   08 09 45    Fire Alarm Control Panel IQ8Control C M    5 3 Primary loop functions  Access levels 3 and 4     Authorisation for access levels 3 and 4 is required in order to use the primary loop function    Using this function  primary loops including all connected zones and loop devices can be switched on or off at  the keypad  The switching state is indicated on the control panel and the alphanumeric display    The primary loop functions are configured via the service PC and the tools 8000 programming software  More  information can be found in the program online help     Primary loop   Transfer route  Primary loop   U    1 on off  2 reset       Fig  46  Entering the primary loop number    Primary loops are     e all analog loop modules included in this FACP   including the analog loop with all associated devices connected to this module     e all 4 zone modules included in this FACP   including all zones and detectors connected to this module     e certain modules such as relays or the interface on the basic peripheral module    Switch on   disconnect Primary loops   e Enter the 4 digit primary loop number which is to be switched on and press the Select function key    e Enter the number of the desired function  1   switch on reset  2   switch off  or select the menu point with  th
35. r keys for displaying messages in the display can  still be operated when the keyboard is blocked     Key switch in horizontal position    locked       unlocked    Fig  3  Keyboard unlocked       e The keyboard is unlocked for the operation of the single IQ8Control and other processors interconnected  through the essernet   or other networks     e The display menu is activated     e The common disconnection display may be lit  Depending on the customer data programming  when the  keyboard was unlocked  at least one zone  one output or one component of the fire alarm control panel   such as the master box  was switched off     not be alarmed  automatically     N In case of a fire alarm  FACP will disable the activation of the master box  MB   The fire brigade will  In case of an event  the red LED  gt Notify fire department lt  will be lit     Call the fire department immediately     FB 798950 10 GB0   08 09 7    Fire Alarm Control Panel IQ8Control C M    2 2 Function of the display and operating elements    The display and operating panel of the FACP IQ8Control are available with the standard display or the larger  Ya VGA display in both variants  In this documentation  the display is described using the 4 line standard display  as an example  Slight differences in how information is displayed are possible with the 1   4 VGA display        Fig  4  Operating elements   keypad   display Operating elements   keypad   1 4 VGA display      Common displays         Alphanumeric disp
36. rm devices and master boxes will not transmit an alarm in the case of an event   The fire brigade is not notified automatically     FB 798950  10 GBO   08 09    15    Fire Alarm Control Panel IQ8Control C M    Verify    If the  gt Delay function lt  is activated  pressing this button during an event  starts the investigation time for delayed activation of the master box     SB The first and last messages with the highest priority appear in the display  again without the need to press any other buttons        The  gt  Verify  lt  function is described in Chapter 4 7     Additional messages are shown on the display  They can be selected with the Cursor keys   The first and last messages with the highest priority appear in the display again without the need    to press any other buttons     When this key is pressed  the delay time is enabled disabled   toggle function      Refer to chapter 4 7 Delay Verify        Buzzer off    Buzzer off Acknowledgement of the control panel buzzer   ee This key remains active when the keyboard is locked     The buzzer is reactivated in the case of a further event        16 FB 798950  10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    2 3 Operating panel with FBA    Part No  786207     The panel front with integrated Fire department operating and indicating panel  FBA  is an optional device for  use of the Fire Alarm Control Panel IQ8Control in Swiss     In accordance to the requirements of the common national Fire assurance companies  
37. s fire alarm control panel has detected 6 fire alarms and 2 technical alarms up to now  The sum of all alarm  signals detected in the essernet   network amounts to 50 fire alarms and 2 technical alarms  TAL alarms      The alarm counter cannot be reset to   0000     40 FB 798950  10 GB0   08 09    Fire Alarm Control Panel IQ8Control C M    4 9 Lamp test    Using the  gt Lamp test lt  function  all the light emitting diodes  LED  and the internal panel buzzer are activated  for approx  10 seconds to check the optical and audible display of the operating panel     Test    Press key    Fig  41  Lamp test start    e All optical displays  LED  of the operating panel and the single zone indicator unit  if installed  illuminate  e The display area of the alphanumeric display is completely darkened  e The control panel buzzer sounds    e The version number of the panel software is then shown on the display    This function ends automatically after approx  10 seconds   Pressing the  gt Test lt  key again stops the lamp test before the expiry of 10 seconds     FB 798950 10 GBO   08 09 41    Fire Alarm Control Panel IQ8Control C M    5 Service Level    The service level allows the operator to carry out operations or to switch off individual fire detectors and primary  loops in a functional fire alarm system  These functions can also be performed on interconnected control panels  integrated in the essernet   network  i e  independently of the control panel     Fig  42  Function key  Serv
38. s only possible to switch off sensors with the OH  OHG and OHI intelligent fire detectors   If intelligent fire detectors are installed together with single criteria detectors  detectors with just    one sensor  on an analog loop  only the sensors on the intelligent detectors are switched off     Switching on off not permissible  The switching on Disconnection of the detector sensors is indicated in the display     e  f sensors have already been disconnected in an analog loop  for example  gt I G sensor off lt  for all fire  detectors or if there are no sensors of the selected type in this analog loop or a zone disconnect has been  detected  the message  gt Switch on Disconnect not permissible lt  is displayed     e In an analog loop  it is generally only possible to execute a disconnection function  e g  disconnected  sensors or detectors  when no further  lower order disconnected functions have been carried out  i e  when  individual detector sensors within a zone have been disconnected  this zone cannot be additionally  disconnected  as disconnect functions for this zone have been carried out  However  it is possible to switch  off other zones of this analog loop in which sensors detectors have not been disconnected     In order to change the existing sensor switching status  all disconnected detector sensors must first be switched  on  for example with the command all sensors on  After  gt all detector sensors lt  have been switched on  a further  switching off sensor dis
39. sors  H sensors  is not  possible     Sensors  loop   Primary loop   B   ae an    3 V G Sensor off  4 Sensors on    Fig  44  Sensor functions related to primary loops       O detector  gt  Optical fire detector with a single sensor  photoelectric sensor   H detector  gt  Heat detector with a single sensor  Heat sensor   I detector    lonisation smoke detector with a single sensor  lonisation sensors     OH detector   Intelligent fire detectors with two various sensors   OT  Photoelectric and Heat sensor     OHG detector   gt  Intelligent fire detectors with three various sensors   OTG  Photoelectric   Heat   and Gas sensors    OHl detector   Intelligent fire detectors with three various sensors   OTI  Photoelectric   Heat   and lonisation sensors     Deactivated groups and detectors do not register an alarm if an event occurs     It is only possible to switch off sensors with the OH  OHG and OHI intelligent fire detectors     FB 798950  10 GBO0   08 09 43    Fire Alarm Control Panel IQ8Control C M       Example of switching off sensors in an analog loop     e Enter the primary loop number of the analog loop in which the sensors are to be switched off and press the  Select function key    e Enter the number of the desired function  1   O sensor off  2   Ol sensor off  3   I G sensor off  4   all  sensors on  or select the function with the cursor keys and press the Function key    The selected sensor type is switched off on all intelligent detectors on the analog loop     It i
40. t   gt Add  Text lt  is not displayed     If  gt information or additional text and a parameter lt  have been programmed for a message  the information and  additional text is always displayed first  Pushing the Param  AT function key during the display of the additional  text shows the parameter     Example of an info text display  Fig  14     Access to programmed information text for this message programmed in the customer data and related to the  zones  max  4 lines   40 characters per line  can be attained by pressing the function key Info   In this example  the following two line info text was programmed for zone 02 in a fire condition     Access via stairway right   Inform Mr  J  Smith  Tel  02137  99152     Info text   additional text and parameter display    Pressing the Condition function key  gt returns lt  the panel to the condition display  The display  switches automatically to the preceding menu point without the need to press any additional    buttons     FB 798950 10 GB0   08 09 27    Fire Alarm Control Panel IQ8Control C M    4 2 Entering time date    Time fct  Time Date  Time   10 4  Date   Tu  02 06 99    Delay on we Off       Fig  15  Entering time date       Entering the time or the date is carried out under the  gt Time functions lt  menu point  which is accessed by  pressing the corresponding function key     The corresponding input field  hour  minute  day  etc   is marked using the cursor keys and the desired value is  entered on the numeric keypad  W
41. t is indicated optically by the common display   gt Disconnect lt  on the control panel and the corresponding continuous lighting of the yellow LED on the single  zone indicator unit  if present      1  Disconnect Zone  0004 Det  15 11 10 22 11  Additional text  client text     Fig  20  Disconnect to status display       A A disconnected zone will not signal an alarm in the case of an event     30 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M    4 3 3 Status ofa zone    With this function  the current status  e g   gt Normal lt    gt Alarm lt  and  gt Trouble lt   of the corresponding zone can be  interrogated directly     Zone Status query    w 0       Fig  21  Status zone 2  example     Press key    Operation Zone   0002  Status  normal    Fig  22  Display Status zone 2       FB 798950 10 GB0   08 09 31    Fire Alarm Control Panel IQ8Control C M    4 4 Detectors    Functions relating to detectors are only possible for addressable fire detectors of the detector series 9100 and  9200 and IQ8Quad  These fire detectors can be selected and controlled by a detector address     4 4 1 Switching on   resetting a detector    With switch on  an individual disconnected detector of the selected zone is switched into the operative status or  an active detector is reset and any imminent messages such as  gt Fire lt  or  gt Trouble lt  for this detector are  deleted     Please note that the zone number has to be entered before the detector number       0   0 0      F
42. tatht ie a aa ee eds 40   ZB SE  N   11111 6 0  9  1  E E AA PE PT EEA E A A A E EEA E I EA 40  49 gt  EAD IESI aee aE E EE a ae Ne a eh 41   5 SEIVICE  Level area N aden a aiia 42  5 1  Sens  r f  netions  oop  nanea a A a a 43  5 2 Sensor functions  zone detector                 rnnnnnnnenennennnnnnnnnnnnnnnnnnnnnnnnennnennennnnnnnennnnennennnen unanenn nat 45  5 3 Primary loop functions  Access levels 3 and 4                snnenennnnnnennnennnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnennnennnnnnn 46    FB 798950 10 GB0   08 09 3    Fire Alarm Control Panel IQ8Control C M       1 General    Thank you for buying a product from Esser by Honeywell    The quality and reliability of Esser products are well known and ensure the highest level of safety at their  installation location for many  many years  This user manual in combination with the instructions provided by  your installer will quickly provide you with extensive information about the operation of the IQ8Control C M fire  alarm control panel  We recommend that you read this user manual thoroughly and keep it together with the  technical documentation of the fire alarm control panel  If you have any questions  please contact your installer     To equip buildings  facilities  commonly frequented areas and working spaces with a fire warning system can  only be carried out economically and with reasonable propriety when correspondingly well founded safety  concepts are developed and accordingly applied    Wherever the highest requir
43. ther conditions of the fire alarm control panel are displayed  sorted by priority     If more messages are imminent than can be shown in the display  it is possible to  scroll  in the display with the  cursor keys     Overview 13 51 28 04    I Fire   1 message  Switch off   1 message  Switch off AE   2 messages       Fig  35  Display overview    For a detailed status display of a particular message  mark the corresponding message line with the cursor and  press the function key  gt Status lt      1  FIRE Det Zone  002 Det 0 14 10 28 04 PR  EDP room  paper store 1        Fig  36  Display for a detailed status message fire alarm  example          Additional text line associated with the triggered zone detector  example        Additional information or parameters may be displayed by pressing function key  gt Info lt      38 FB 798950  10 GBO   08 09    Fire Alarm Control Panel IQ8Control C M    4 7 Delay and Verify    A switching time can be entered under this menu point  gt Time functions lt  by the operator of the fire alarm  system in addition to the switching times programmed under the  gt Delay Verify lt  function in the customer data  if  programmed by the installer      Please consult your installer to find out whether the function  gt Delay Verify lt  has been programmed in the  customer data of your fire alarm control panel  If this function is not activated  e g  for technical reasons or  requirements  the functions described in this section cannot be used     If a fir
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
IF632 Insallation and Service Manual  Western Digital Scorpio Blue 750GB, SATA 3 Gb/s    TEFAL TW583388 Instruction Manual  Telus IP1000 User's Manual  Ata - Tribunal de Contas da União  Remote DVR Control User Manual  none 0282018 Use and Care Manual  VGN-AR650U      Copyright © All rights reserved. 