Home

RFS System Quick Start Guide Rev 2.1

image

Contents

1. o Installation of NEM ALD A or NEM ALD S To run the installation setup the user must have administrator rights on the system Read sections 1 1 to check the system and software environments In the following sections the procedure for installing the NEM application is described it applies to both the NEM ALD S and NEM ALD A versions From the CD or the folder where the NEM ALD setup program is located double click the executable and follow the instructions to install NEM ALD to the local PC The user must have write permission for the directory where the software will be installed C Temp k nl x Ale Edit View Favorites Tools Help qe Gt Q IE Use Caries up ob X E gl Address C Temp E gt Go i Nam o __ Size Type Date Modified fe NEM ALD 3 0 7 setup exe JB 187KB Applicaton 21 12 2007 13 56 1 objects 27 5 MB My Computer Al Figure 1 1 Launching the NEM ALD S setup Double click the icon to launch the installation RADIO FREQUENCY SYSTEMS March 25 2007 7 38 The Clear Ch oi c e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o ge HEM ALD S 3 0 7 Excelsior Installer Welcome to Excelsior Installer for NEM ALD 5 3 0 7 Excelsior Installer will quide you through installation of the software on your computer To proceed click Next Figure 1 2 Starting the
2. Figure 1 4 Selecting the appropriate user Click the Next button to continue ge NEM ALD S 3 0 7 Excelsior Installer Destination folder Select destination Folder The installer will install NEM ALD 5 3 0 7 components to the Following Folder To install to this Folder click Next To install to a different Folder click Browse and choose another folder Destination folder C Program Files WEM ALD 5 3 0 7 Browse Space required on C 64452 K Space available an C 3140132 K OO e Cancel Figure 1 5 Selecting the destination folder RADIO FREQUENCY SYSTEMS March 25 2007 9 38 Chnoic e The Clear RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o If it is necessary click the Browse button to modify the destination folder by default it will be installed under C Program Files Click the Next button Y5 HEM ALD S 3 0 7 Excelsior Installer Shortcut icons Select shortcuts you wank to create Create shortcut icons in the Following locations Desktop Back Next gt Cancel Figure 1 6 Creating a shortcut Click the Next button to continue LIA HEM ALD S 3 0 7 Excelsior Installer Start installation View current settings The installer is ready to install NEM 4LD 5 3 0 7 on your computer Click Nest to begin the installation or Back bo change the current se
3. Intemet or a network Q On recommended This setting blocks all outside sources from connecting to this computer with the exception of those selected on the Exceptions tab Don t allow exceptions Select this when you connect to public networks in less secure locations such as airports You will not be notified when Windows Firewall blocks programs Selections on the Exceptions tab will be ignored Q C Off not recommended Avoid using this setting Turning off Windows Firewall may make this computer more vulnerable to viruses and intruders Windows Firewall is using your non domain settings What else should know about Windows Firewall RADIO FREQUENCY SYSTEMS March 25 2007 14 38 The Clear Choict se RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Select the Exceptions tab and click Add Program button Firewall Ka General Exceptions Advanced Windows Firewall is turned off Your computer is at risk of attacks and intrusions from outside sources such as the Internet We recommend that you click the General tab and select On Add a Program x To allow communications with a program by adding it to the Exceptions list select the program or click Browse to search for one that is not listed Programs McAfee Desktop Firewall wir Minesweeper amp Mozilla Firefox MEN d NetScreen Remo
4. an IP address automatically ivi z File and Frinter Sharing for Microsoft Networks Use the following IP address vi JE QoS Packet Scheduler v Intemet Protocol TCP IP IP address 132 188 1 101 oe Subnet mask 255 255 255 D Default gateway 192 168 1 0 Install Description C Gbtsin DNS server address automatically Transmission Control Protocal Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Use the following DNS server addresses Preferred DNS server f MV Show icon in notification area when connected Altemate DNS server MV Notify me when this connection has limited or no connectivity Figure 2 11 Setting the IP address of the PC Once complete hit the OK buttons RADIO FREQUENCY SYSTEMS The STEM March 25 2007 20 38 Clear Chnoict e 2 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 2 2 o Dynamic IP address Connect the CNI and the PC to the same network The PC and PPP ports of the CNI should remain disconnected The DHCP server that provides the dynamic IP addresses must be running on the same network as the CNI and the PC To configure the network as in section 2 1 2 go to Control Panel and click Network connections icon highlight the loc
5. no connectivity Cancel Figure 2 12 Setting the PC network to DHCP mode RADIO FREQUENCY SYSTEMS March 25 2007 21 38 Clear Choice The RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Using a retail router as the DHCP router 1 Make sure the PC is configured to get an IP address automatically as described previously 2 Connect an Ethernet cable from the router any port except the Ethernet port to the PC do the same for the CNI Ethernet port on the left of its front panel VW T Setup with a retail router Connection at the router detail RADIO FREQUENCY SYSTEMS March 25 2007 22 38 The Clear Choice 2 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 o 3 Power up the router 4 Power up the CNI which is going to request its IP address from the router then it scans the ALDs orange LEDs scrolling and eventually the 4 green LEDs will be on 5 Once completed on the front panel of the router the LED of each connected port turns green it may blink when there is some traffic 6 If it failed start again to step 1 and recycle the power of the router before the power of the CNI To verify that there is some traffic between the PC and the router go to control panel network Connection the Local Area Connection should be d
6. 192 168 1 168 with 32 bytes of data Reply from 172 168 1 188 bytes 32 time 5ms ITL 64 Reply from 1972 168 1 188 bytes 32 time ims TIL 64 Reply from 192 168 1 1BHB8 bytes 32 time 2ms ITIL 64 Reply from 192 168 1 1806 bytes 32 time 2ms TT L 64 Ping statistics for 192 168 1 1868 Packets Sent 4 Received 4 Lost H Hx loss Approximate round trip times in milli seconds Minimum ims Maximum Sms Average 2ms C Documents and Settings lt mguillou gt Figure 8 3 Result of the ping command RADIO FREQUENCY SYSTEMS March 25 2007 32 38 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o If the ping command doesn t work check with IT administrator the IP address configuration address netmask gateway and the router configuration firewall filter The PC and CNIs must belong to the same subnetwork Notes for the IT administrator NEM ALD S uses ping SNMP port 161 and FTP protocol which shall be authorized by network connection 8 3 How to download a new Antenna Configuration file Please refer to the user guide of the appropriate NEM application and to the section RET configuration 8 4 How to upgrade the CNI firmware The CNI can be configured to manage a different protocol This operation is carried out by upgrading its firmware Select the Tools CNI SW Upload menu 192 158 1 100 161 ME
7. 2 158 1 101 2000 Set Hestart Counter 272 Scan Counter h 301 Setting the trap address of the CNI RADIO FREQUENCY SYSTEMS March 25 2007 36 38 The Clear Choi c e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 8 6 How to update the NEM ALD S or NEM ALD A applications Before installing a new application the already installed NEM ALD S program must be removed There are 2 ways to uninstall NEM ALD e Open the Control panel launch the Add or Remove Programs once the list refreshed select the NEM ALD S or NEM ALD A program and click Hemove button F Add or Remove Programs am Ka Change or Remove Programs K Add New Programs 10 x Sort by Name 4 01MB aj Currently installed programs Show updates Ray Microsoft Office PowerPoint Viewer 2003 Size Microsoft Office Professional Edition 2003 amp Mozilla Firefox 2 0 0 11 Size 21 68MB jl MSXML 4 0 5P2 KB925672 fe MSXML 4 0 SP2 KB927978 E MSXML 4 0 SP2 KB936181 Ce am Add Remove Win Components jl MSXML 6 0 Parser KB933579 jl NEM ALD A 2 3 jS NEM ALD 5 2 1 B NEM ALD S 3 0 7 Last Used On 29 11 20 Change Rel Gre 2 51MB To change this program or remove it From your computer click Change Remove S Netscreen VPN Clienk Security Policy V14 GENERAL gt Notepad i9 Opera 9 0 g Optimizer RT AISG v1 1
8. 8 QuickTime jS RET AN AT 024 o Size Figure 8 4 Removing the application through the control panel RADIO FREQUENCY SYSTEMS Clear Chnoit e March 25 2007 37 38 The RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o e From the Start menu select the NEM ALD program and click the installation Tg Lk Y Lef ball bk 8 e amp y Microsoft Photo m LeBackup32 Light b ES Microsoft Excel Micrasoft Office Power Livebox KE l 4 Opera len Lotus Applications SE PowerPoint Lotus SmartSuite b Microsoft Word pu a Notepad 7 McAfee Desktop Firewall e donis Microsoft Office b Outlook SE a WinSCP im Mozilla Firefox Ra Remote Assistance zi gt Software Setup NEM ALD A 2 3 J Disk Cleanup im NEM ALD 5 2 4 S i MEM ALD 5 3 0 7 d M LocateIP All Programs Mile EH z ALD J fj NetScreen Remote k ex NEM ALD 5 3 0 7 e Windows Media Player Network Associates 2 Uninstall 7j Notepad k W star e Ej 4 7 Outils Microsoft Office d Figure 8 5 Removing the application through the Start menu RADIO FREQUENCY SYSTEMS March 25 2007 38 38 The Clear cn ice
9. 8 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o The HDLC address of the ACU A11S N dedicated for Siemens AISG 1 1 NodeB is preset to 8 Do not connect the NEM ALD A to those devices because it will erase and set a different address to them RADIO FREQUENCY SYSTEMS March 25 2007 5 38 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 1 Installation of AISG System 1 1 System environment NEM ALD S communicates through a crossover Ethernet cable connected to the Ethernet port of the CNI it includes the latest embedded software for the CNI TMA and RET NEM ALD A communicates through a special serial cable connected to the PC port of the CNI or through the protocol adapter Required PC software e Windows XP SP1 or SP2 Since Release 3 the NEM ALD applications do not require the Java Virtual Machine JVM installed on the computer Minimum hardware requirements for NEM ALD A and NEM ALD S Screen resolution 1024x768 or greater 256 MB of RAM or more 1 5 GHz system clock or more 6 MB hard disk space or more RADIO FREQUENCY SYSTEMS March 255 2007 6 38 The Ci agr Chnoict e 2 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 1 2
10. AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 o Version Date Modified by Type of Changes Status 0 1 2006 11 08 GOUEZEL Y First draft Preliminary 1 0 2006 11 21 GUILLOU M First release 1 1 2007 03 05 GUILLOU M Revised added screenshots 1 2 2007 03 25 GUILLOU M Add photos and site commissioning 1 3 2007 08 07 GUILLOU M Java environment 1 4 2007 09 06 GUILLOU M Revised Java installation and environment updated 2 0 2008 01 04 GUILLOU M Updated NEM ALD applications are Java independent 2 1 2008 01 25 GUILLOU M Caution for connecting the NEM ALD A to the ACU A11S N RADIO FREQUENCY SYSTEMS March 255 2007 3 38 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Conventions This Guide Uses The text that the user enters is between quotes Do not key in the quotes The text or icon displayed by the computer is between double quotes Special keys of the keyboard are surrounded by lt and gt SPACE is the space character to enter it press the spacebar of the keyboard Click means press the left mouse button once and release it immediately Double click is press the left button twice in rapid succession Right click means press the right mouse button once and release it immediately RADIO FREQUENCY SYSTEMS March 25 2007 4 3
11. Lotus Applications cw E Remote Assistance lt gt Software Setup b Windows Media Connect e ce NM MUN Windows Media Player Le CX Windows Messenger TA McAfee Desktop Firewall VW 3 SA windows Movie Maker 7 Microsoft Office k 3 e Mozilla FireFox 7 MEM ALD A 2 1 7 NEM ALD 5 1 4 fili NEM ALD 5 2 0 r own or hl NEM ALD 5 2 0 ds T MEM ALD 5 M 1 5 ii RFSLocateIP 1 0 fan MetScreen Remote fan Network Associates SS I LLLAILULULM A start amp E 4 7 Outils Microsoft Office Figure 2 6 Launching the tool to set the IP address RADIO FREQUENCY SYSTEMS March 25 2007 17 38 The Clear Chnoict e 2 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 o ei RES CNI IP Locate Configure X Hit Search to locate boards Configure to change settings Search Configure Help Using address 0 0 0 0 port 15622 to find remate boards H Search Complete Figure 2 7 RFS CNI IP address setting tool Click Configure button Select Set Manually and type in the IP address settings IP Address for instance 192 168 1 100 Net Mask 255 255 255 0 Gateway 192 168 1 0 x C Use DHCP for settings Ce Set Manually Cancel DHEP 5atting En Hostname Manual Settings z pe p pe IP Address 192 De Dm Nat Mask 285 255 255 E Gateway E jes Eoi a Figure 2 8 Setting
12. M ALD 5 AISG2Z U File Devices Tools Help CN SWlpload NS ALD Setup is amp b ALD Site Update Multiple ALD Site Update Arder by CNI output port Ba HI items CNE RF105708g o Port 3 RADIO FREQUENCY SYSTEMS March 25 2007 33 38 The Clear cn ice RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o The following window will pop up Y Parallel CNI Software Uploader loj x X Read Configuration File CNI Target Adress es 192 168 1 100 Software Filename Remote Filename Add to Upload List Remove from Upload List Number of simultanous uploads 10 List of CNIs and their Softwares to upload Start upload process Write Result File The address of the CNI to which the PC is connected appears into the CNI Target textbox Click the button to choose the appropriate CNI firmware to download Into the window that pops up click the file to be downloaded and make sure its name is in the File name textbox then click Open VEO muc o o x Read Configuration File NI Tarnet ddrecsiect M q216528141nn egen MET j ld pE ec pl Em Rechercher dans me CNI Modbus e ei ed ica 3 p i enia Nom de fichier cniAppIME_208 rfs_ 1 Fichiers du typ
13. RADIO FREQUENCY SYSTEMS The Clear Choice RFS Mobdus amp AISG CNI ACU NEM ALD A NEM Systems ALD S Quick start Guide 10 000 000 492 REV 2 1 Authors Maurice Guillou Yann Gouezel Project Visa TE David Detlef Andr Kiesling Block Doll Renard d Arvil RADIO FREQUENCY SYSTEMS March 25 2007 1 38 The Clear Choi ee RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 o Table of Contents Conventions This Guide Uses 4 Caution 5 1 Installation of AISG System 6 1 1 System environment 6 1 2 Installation of NEM ALD A or NEM ALD S 7 2 Configuration of the AISG system in Ethernet mode 13 2 1 X Static IP address 17 2 1 1 Setting the IP address of the CNI 17 2 1 2 Setting the IP address of the PC 19 2 2 Dynamic IP address 21 3 Configuration of the AISG system in Serial mode 24 4 Connecting the outputs 24 5 Running the AISG system in Ethernet mode 28 6 Running the AISG system in serial mode 29 7 Site commissioning 30 8 FAQ 31 8 1 RFSLocatelP cannot detect the CNI 31 8 2 NEM ALD S indicates that the CNI cannot be reached 32 8 3 How to download a new Antenna Configuration file 33 8 4 How to upgrade the CNI firmware 33 8 5 Some windows are not refreshed in NEM ALD S 36 8 6 How to update the NEM ALD S or NEM ALD A applications 37 RADIO FREQUENCY SYSTEMS March 255 2007 2 38 The Ci agr Chnoict e RFS Modbus amp
14. SYSTEMS March 25 2007 28 38 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 6 Running the AISG system in serial mode Double click the NEM ALD A icon the application opens a login dialog box Select the COM port of the computer to which the serial cable is connected then type your user ID and password If there is a problem with the access to the CNI an error dialog box Error setting up data manager can not open serial port will pop up in that case check if this COM port exists or is not already in use Prior to connecting or disconnecting an AISG jumper from the output please switch off the CNI RADIO FREQUENCY SYSTEMS March 25 2007 29 38 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 7 Site commissioning Once the CNI is on run NEM ALD S which starts by scanning the devices connected to the 3 outputs Every RET must be configured and calibrated before operation Please refer to the section NEM ALD ACU configuration in the user manual There is mandatory information required before the site can be controlled remotely The CNI IP address described in sections 2 1 1 and 2 2 Each RET Serial Number must be assigned a Sector ID and Antenna Model Number up to 15 characters E
15. ach TMA must be assigned a sector ID The Sector ID is a text string with up to 4 characters for Modbus and AISG 1 1 or 32 for AISG 2 0 Also the following information is optional but can be useful The CNI location 0 to 32 characters and baseStation ID 0 to 12 The devices installation date RADIO FREQUENCY SYSTEMS March 255 2007 30 38 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 8 1 RFSLocatelP cannot detect the CNI The host PC must have an IP address For verification launch Start Run then type cmd and click OK button Maurice GUILLOU i Li Lotus Organizer My Documents My Recent Documents gt EM Microsoft Word Gi My Pictures A gt a Adobe Reader 7 0 y My Music KE My Computer Oxford SuperLex E e J My Network Places A Microsoft Excel Ce Control Panel Microsoft PowerPoint GH Set Program Access and Defaults amp y Microsoft Photo Editor e ConnectTo H 2 Printers and Faxes Help and Support Search All Programs gt OG HP Info Center Log Off 9 Shut Down stat 3 OG 38 Windows E Ro eee 21 a Type the name of a program folder document or Ss Internet resource and Windows will open it Far you Open Y Cancel Browse Figure 8 1 Launching the Command window Type in ipconfig at the p
16. al Area Connection right click and select properties Select Internet Protocol TCP IP and click the Properties button Depending on the DHCP server leave as Obtain an IP address automatically or set the IP address provided by the DHCP server in that case set the subnet mask to 255 255 255 0 KAES Internet Protocol TCP IP Properties 2 x General Authentication Advanced General Altemate Configuration Connect using You can get IP settings assigned automatically if your network supports this capability Dtherwise you need to ask your network administrator for Bi Broadcom NetXtreme Gigabit Etheme Configure the appropriate IP settings This connection uses the following items e Obtain an IP address automatically wi JB File and Printer Sharing for Microsoft Networks C Use the following IP address vi dall QoS Packet Scheduler B adds x Internet Protocol TCP IP M b wbnet mask b etaull gate Way Install Properties D Transmission Control Protocal Internet Protocol The default r Description Obtain DNS server address automatically C Use the following DNS server addresses wide area network protocol that provides communication across diverse interconnected networks Prefered DNS sener n PEE Altemate DNS server M Show icon in notification area when connected 3 Advanced Iw Notify me when this connection has limited or
17. dte RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o BEE 0 Resetting CNI 182 158 1 100 0 Waiting far CMI ta bein BOOT made 192 168 1 100 0 CNI software upload in process 192 168 1 100 Im Waiting for CMI ta be in APPLICATION mode 192 166 1 100 Ift MI software Upload successful 1927 166 1 100 Help abort Close this window by clicking on the x at its top and right corner and also the CNI software uploader The CNI will perform a scanning of the elements connected to the 3 outputs the CNI is able to identify only the devices that use the same protocol 8 5 Some windows are not refreshed in NEM ALD S The reason why the windows are not refreshed during a scanning or a tilt setting is because NEM ALD S did not receive the acknowledge from the CNI Make sure that the firewall does not block NEM ALD S terminate and re launch the NEM ALD S application once the power of the CNI has been recycled The trap address of the CNI must be set this is the IP address Port Number to which the CNI will send the traps signal that a task such as setting the tilt is complete or error messages It should be the IP address of the computer where NEM ALD S is running In NEM ALD S click the status of the CNI and key in the IP address of the PC followed by 2000 then click the Set button Configuration Trap Address 18
18. e Tous les fichiers v Ouvrir Annuler Start upload process Write Result File RADIO FREQUENCY SYSTEMS March 25 2007 34 38 The Clear Choisct e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Click Add to Upload List button first and then on Start upload process button X Parallel CNI Software Uploader inl x Read Configuration File CNI Target Adress es Software Filename H hCNI Modbusicn IAppIME_208 rfs Remote Filename cni amp pplME 208 tts Add to Upload List Remove from Upload List Number of simultanous uploads 0 List of CNIs and their Softwares to upload 192 168 1 100 C Program Files NEM ALD S 2 0 Embedded Software CNIiCNI Modbus ict D i D i Start upload process Ds Write Result File A new window shows each step of the downloading process BER t Resetting CNI 192 166 1 100 0l Waiting for CMI to be in BOOT made 192 168 1 700 0 CA sothware Upload in process 192 166 171 100 This operation may last a couple minutes a message showing it is complete will prompt in the Uploading window The operating system may display messages such as disconnected network during the process RADIO FREQUENCY SYSTEMS March 25 2007 35 38 The Clear Cheoi
19. he Clear Ch oi c e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Windows Firewall helps protect your computer by preventing unauthorized users from gaining access to your computer through the Internet or a network Q C On recommended This setting blocks all autside sources from connecting to this computer with the exception of those selected on the Exceptions tab Don t allow exceptions Select this when you connect ta public networks in less secure locations such as airports You will not be notified when Windows Firewall blacks programs Selections on the Exceptions tab will be ignored Q Off not recommended Avoid using this setting Turning off Windows Firewall may make this computer more vulnerable to viruses and intruders Windows Firewall is using your non domain settings What else should know about Windows Firewall Figure 2 2 Disable the firewall An alternative way Instead of having the firewall off it is possible to allow exceptions such as for NEM ALD S so that it may access to the network without the firewall blocking it After selecting the Windows Firewall from the control panel check the On recommended option 7 Windows Firewall E x General Exceptions Advanced Your PC is not protected turn on Windows Firewall Windows Firewall helps protect your computer by preventing unauthorized users from gaining access to your computer through the
20. installation Click the Next button to continue ge NEM ALD S 3 0 7 Excelsior Installer License agreement Installation and use of MEM ALD 5 3 0 7 requires acceptance of this license agreement END USER LICENSE AGREEMENT RADIO FREQUENCY SYSTEMS IMPORTANT THIS END USER LICENSE AGREEMENT EULA IS A LEGAL AGREEMENT BETWEEN YOU AG 4 LICENSEE EITHER AN INDIVIDUAL OR A LEGAL ENTITY AND RADIO FREQUENCY SYSTEMS CRFS or LICENSOR BY INSTALLING OR USING THE SOFTWARE PRODUCT The PRODUCT THE INDIVIDUAL OR ENTITY LICENSING THE PRODUCT I5 CONSENTING TO BE BOUND BY AND I5 BECOMING amp PARTY TO THIS AGREEMENT IF LICENSEE DOES NOT AGREE TO ALL OF THE TERMS OF THIS AGREEMENT THE SOFTWARE MUST NOT BE INSTALLED OR USED THIS PRODUCT IS NOT SOLD BUT LICENSED T accept the terms of the license agreement M1 do not accept the terms of the license agreement Figure 1 3 Accepting the End User License Agreement Click the Next button RADIO FREQUENCY SYSTEMS March 25 2007 3 38 The Clear Choice RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S 2 o ge NEM ALD S 3 0 7 Excelsior Installer Installation type Choose the type of installation Select Common Profile to install the software For all users of the computer or Personal Profile For the current user only t 2 Personal Loi Common lt Back next gt Cancel
21. isplayed If the router is off or the Ethernet cable is disconnected the status of this network will be Network cable unplugged once the cable has been connected the status is updated to Acquiring the address that should last about 5 seconds When the connection is established the status is Connected Go to control panel network Connection select the Local Area Connection in the list double click it if you right click select Status the connection section should show Connected the numbers of packets sent and received should increase especially when connected to the web page of the router To figure out the IP address of the PC go to control panel network Connection select the Local Area Connection in the list right click it and select Status and then the Support tab the IP address of the PC is displayed Other solution when starting NEM ALD S it opens a DOS window where it displays after a couple of seconds the IP address of the PC By accessing to the web page of the router the DHCP client table lists the IP addresses of all connected devices RADIO FREQUENCY SYSTEMS March 25 2007 23 38 Clear Choice The CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e e e O e e e 3 Configuration of the AISG system in Serial mode To set up the CNI and the AISG network turn off the power supply of the CNI Connect the serial cable from the computer to
22. rk Connections I mi x File Edt View Favorites Tools Advanced Help ay ge H CH Fe i vi PE Q e gt d P Search mw Folders dy j x ie FE Address e Network Connections x SE LAN or High Speed Internet 7 Wireless Network Connection 3 LAM or High Speed Inter Disabled Intel R PRO Wireless 22 1204 Connection LAM or High Speed Inter Disabled 1394 Met Adapter LAM or High Speed Inter Connected Broadcom Metxbreme Gig 2I ocal Area Connection Disable Wizard Status Repair sl New Connection Wizard 4 Bridge Connections k d Yiew or changes Create Shortcut Delete uch as adapter protocol or modem configuration settings Rename Figure 2 10 Configuring the Ethernet network of the PC Select Internet Protocol TCP IP and click the Properties button Select Use the following IP address and type in the PC IP address o IP Address for instance 192 168 1 101 o Subnet Mask 255 255 255 0 o Default Gateway 192 168 1 0 4 Local Area Connection Properties 2 zl mem Protocol TCP IP Propert 2 x General Authentication Advanced General Connect using You can get IP settings assigned automatically if your network supports E this capability Otherwise you need to ask your network administrator for Sai Broadcom Netxtreme Gigabit Etherne Configure the ond e IP settin p y This connection uses the following items C Obtain
23. rompt into the console window followed by ENTER and check the IP settings RADIO FREQUENCY SYSTEMS March 25 2007 31 38 The Clear Chnoict e CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o c Ch WINDOWS system32 cmd exe Microsoft Windows XP Version 5 1 2600 lt C Copyright 1985 28061 Microsoft Corp C Documents and Settings mguillou gt ipconf ig Windows IP Configuration Ethernet adapter Local Area Connection Connection specific DNS Suffix IP Address 192 168 1 161 255 255 255 0 Default Gateway C Documents and Settings mguillou gt Figur 8 2 ipconfig to verify the IP setting of the computer Please refer to section 2 1 2 to set the PC IP address Contact the IT department so that the host PC has the permission to access to the network of the CNIs NEM ALD S indicates that the CNI cannot be reached The connection between host and CNI must be configured to allow access from NEM ALD S To check it ping the CNI launch Start Run then type cmd and click OK button type in ping followed by a space and the IP address of the CNI at the prompt into the console window ENTER The expected result is to show that no packet was lost and without any timeout c 5 WINDOWS system3z cmud esxe Microsoft Windows HP Uersion 5 1 2600 CC Copyright 1985 2661 Microsoft Corp C Documents and Settings mquillousping 192 168 1 106 Pinging
24. run NEM ALD A March 25 2007 12 38 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 2 Configuration of the AISG system in Ethernet mode Caution Before modifying the network parameters of the PC write down the current configuration to be able to set it back again The CNI can be configured in either the static or dynamic IP address mode sections 2 1 and 2 2 cover these two topics but let us focus on the setting of the firewall first No firewall should be active between the CNI and PC from the Start menu go to Control Panel double click Windows Firewall icon and disable the firewall E Control Panel S mj x Wi Dark gt dm re Search s Folders 1 3 x le zl Address jet Control Panel Go Keyboard Mouse Network Phone and Portable Media Power Options Printers and ProtectTools Connections Modem Devices Faxes Security m e Q 8 5 m oe Quick Launch QuickTime Regional and Scanners and Scheduled Security SoundMan Sounds and Buttons Language Cameras Tasks Center Audio Devices e x IR e C wv Speech System Taskbar and User Accounts Miete Windows Wireless Link Wireless Start Menu Media Connect Network Set Firewall z Configure the Windows Firewall Figure 2 1 Selecting the firewall in the control panel RADIO FREQUENCY SYSTEMS March 25 2007 13 38 T
25. s at risk of attacks and intrusions from outside sources such as the Internet We recommend that you click the General tab and select On Programs and Services File and Printer Sharing M Irelke M nemal SNMP gnostics for Windows XP v Remote Se Remote Desktop UPnP Framework v ViewLog v VPN Connection Manager xl Add Program Add Program Add Port Edit Delete IV Display a notification when Windows Firewall blocks a program at are isks of allowing exceptions Figure 2 5 NEM ALD S may bypass the firewall RADIO FREQUENCY SYSTEMS March 25 2007 16 38 The Clear Choice RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 2 1 Static IP address This is valid for version 2 0 and above of NEM ALD S The PC and PPP ports of the CNI should remain disconnected Both the CNI and PC must have a static IP address and be connected to the same network a direct Ethernet cable between the PC and CNI is also an option 2 1 1 Setting the IP address of the CNI If it is necessary to change the IP address of the CNI the IP may not be set yet or has to be re configured from the Start All Programs menu launch the RFSLocatelP program 9 Interwise d Microsoft Excel a Java Web Start 4 Opera fan Le Robert amp Collins A E Microsoft Powel E LeBackup3z Light fan LiveBox EG Command Prom Ej
26. te Notes Minder Opera i Ki Outlook Express d Oxford SuperLex Pageant TN PDFCreator Path C Program Files Zip 2FMn exe Change scope DK Cancel Cancel Figure 2 3 Allowing exception for NEM ALD S Click the Browse button and select the folder where NEM ALD S is located by default it is under C Program Files NEM ALD S x x Select All Files in the Files of Type menu click the NEM ALD Sxx exe application so that it appears in the File Name select box RADIO FREQUENCY SYSTEMS March 25 2007 15 38 The Clear cn ice RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Windows Firewall e E xj al SNCH Look in NEM ALD S 3 07 sl OF fe My Recent Documents Desktop S jAntennaFiles EmbeddedSoftware jRFSLocatelP NEM ALD 5_3 0 7 exe uy Uninstall exe My Documents ST Mu Computer W ee TE File name NEM ALD S 30 7 exe D Places K Files of type Applications exe com icd Cancel E Figure 2 4 Selecting NEM ALD S as an exception Click Open button and the following window will pop up it shows the NEM ALD S executable in the list of programs that are not blocked by Windows firewall Windows Firewall XI General Exceptions Advanced Windows Firewall is turned off our computer i
27. the PC port of the CNI 4 Connecting the outputs Please make sure that the CNI is off prior to this operation For each of the three output ports e Connect the cable feeding the tower equipments to the Surge Arrestor which can be a Smart Bias Tee in case the AISG signal is mixed into the RF feeder Connecting a Modbus RET to the Surge Arrestor RADIO FREQUENCY SYSTEMS March 25 2007 24 38 CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 gt GA AY Connecting an AISG Smart Bias Tee to the TMA RF feeder e tis possible to daisy chain multiple RETs her d Rin e deet adl ENEE Yr ys alis en b An GM E XE mE MOT VE ride PRU a DEP K AN A b LE LR k Two Modbus RETs daisy chained RADIO FREQUENCY SYSTEMS March 25 2007 25 38 The Clear Choice CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e e O e e e Use an AISG cable to connect the CNI to the Surge Arrestor this can be through an AISG splitter as well f AISG jumper connected to the Surge arrestor Modbus AISG jumper connected to the Smart Bias Tee AISG 2 0 RADIO FREQUENCY SYSTEMS March 25 2007 26 38 The Clear Choirce RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Turn on the power supply of the CNI its 4 greens LEDs should be on before ALD1 ALD2 and ALD3 LEDs
28. the static IP address of the CNI Hit the OK button RADIO FREQUENCY SYSTEMS March 25 2007 18 38 Clear Choirce The RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o It is possible to check that the PC can communicate with the CNI by hitting the Search button in its main screen As a result it should show the configuration that has just been set as depicted in the figure below Hit Search to locate boards Contigure to change settings Search Configure Help Exil Using address 0 0 0 0 port 21 35 to find remote boards IRHesponse trom 192 168 1 100 Mac addr LES c2 c5 35 ec Mask 255 255255 0 Gateway 192 168 1 0 Search Complete Figure 2 9 Verifying the IP configuration of the CNI In a network environment even with a DHCP server running set a different IP address within the same subnet to each CNI 2 1 2 Setting the IP address of the PC In the static IP mode the PC must have its own fixed IP address as well To configure the network go to Control Panel and click Network connections icon highlight the local Area Connection right click and select properties RADIO FREQUENCY SYSTEMS March 25 2007 19 38 The Ci agr Chnoict e 2 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 o s Netwo
29. ttings listed below Current settings Destination Folder CiProgram Files4MEM ALD 5 3 0 7 Programm Folder NEM ALD 5 3 0 7 Create shortcuts on the desktop Figure 1 7 Ready for installation RADIO FREQUENCY SYSTEMS March 25 2007 10 38 The Clear Choict se RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o Click the Next button ge NEM ALD S 3 0 7 Excelsior Installer Installing The installer will copy components of NEM ALD 5 3 0 7 to your computer Please wait while all components are copied Extracting File C Program Files4MEM ALD 5 3 0 Zut uetrt us GOO9 dl Overall progress o cancel Figure 1 9 Completing the installation Click the Finish button RADIO FREQUENCY SYSTEMS March 25 2007 11 38 The Clear Choice 2 RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 o After the installation two shortcuts are created to launch NEM ALD S they are placed in the appropriate locations Start Menu NEM ALD S folder For NEM ALD A run NEM ALD S run NEM ALD S After the installation two shortcuts are created to launch NEM ALD A they are placed in the appropriate locations Start Menu NEM ALD A folder NEM ALD A Desktop icon RADIO FREQUENCY SYSTEMS The Clear Choi t e run NEM ALD A
30. turn off A couple of seconds later the CNI scans the outputs the LEDs turns orange once the scanning process is complete the 4 LEDs are green The system is now ready for use RADIO FREQUENCY SYSTEMS March 25 2007 27 38 The Ci agr Chnoict e RFS Modbus amp AISG Systems CNI ACU NEM ALD A NEM ALD S Quick start Guide 10 000 000 492 REV 2 1 e o 5 Running the AISG system in Ethernet mode Double click the NEM ALD S icon the application opens a command window it displays some text including the IP address of the computer A couple of seconds later a login dialog box will pop up Enter the IP address of the CNI and then type your user ID and password SH UM Uerzion 1 5 H H6 UR Uendor Sun Microsystems Inc 0S Hame Windows AF x6 5 1 dress 192 168 1 141 NEM ALD V2 0 Please enter missing parameters Target CHI Address 192 168 1 100 Username user node bh Password ec L Figure 5 1 Logging to the CNI If there is a problem with the network access to the CNI an error dialog box CNI cannot be reached will pop up in that case check the network and IP configuration see also FAQ Prior to connecting or disconnecting an AISG jumper from the output please switch off the CNI first Please note since the release of NEM ALD S 3 0 the login process has been improved refer to its user guide for details RADIO FREQUENCY

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung  フレグランススプレ・ 取扱説明車  Warehouse of Tiffany T18275TGRB Instructions / Assembly    User Manual  pronostico del tiempo digital con termo  Samsung MID462 flat panel floorstand  User Manual KKT21i  Heating and Domestic Hot Water Systems for Dwellings  User Manual / Warranty Information  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.