1. User Manual Package Contents If you find any contents missing or damaged contact the place of purchase Eyepiece Camera USB Cable ScopePhoto Driver CD ROM Eyepiece Adapter Manual ScopePhoto software is available for option at extra cost Not in standard package Installing the Driver and Softvvare 1 Insert CD into CD ROM drive 2 Select Install camera driver Continue with installation prompts If using Vista please plug the digital eyepiece into the USB slot before installing camera driver and skip step 3 If unidentified publisher Windows Logo Testing appear select continue anyway A 3 Install image software After installation the image software icon will created on the desktop User Manual To Connect Camera Connect the USB cable into a free USB slot on the computer Requires USB 2 0 interface A Nevv Hardvvare Found displays at the bottom right of your PC screen The camera is recognized The found new hardware wizard would start Select Install the software automatically Finish If unidentified publisher Windows Logo Testing appear select continue anyway NOTE 1 Plug the USB connector to board USB2 0 port directly on the back of the PC is recommend 2 Do NOT use anything to extend the USB cable Using the camera 1 Start the MiniSee or ScopePhoto software 2 Start video MiniSee Click on the camera name below Video button ScopePhoto Click on t
2. DirectX 9 0 or later installed 2 0 GHz minimum processor Recommend dual core 2 8GHz or more USB 2 0 Port CD ROM drive 512 MB RAM Recommend 1GB or more 200 MB Free HDD Performance is dependent on the PC s graphics card USB 2 0 is only supported on Windows 2000 Me XP 2003 Vista and 2008 Do not try to use any other Microsoft operating system vvill NOT vvork on a Computer Windows 2000 must have Service Pack 4 or later installed and XP Pro must have Service Pack 2 or later installed in order for the camera to function correctly To check if you have USB2 0 installed on your computer goes to Start gt Settings gt Control Panel gt System or right click on My Computer and select properties from the context menu Click on the Hardware tab and then onto the button Device Manager Within Universal Serial Bus controllers USB controllers you will see a list of USB devices installed on your machine In this example the red arrow is indicating the USB2 0 device USB2 0 controllers may be labeled as USB2 0 controllers however they may also be labeled as Enhanced or Standard Enhanced controllers The so called Standard or Standard Universal controllers are for the slower USB1 x system z O Controller 5 Standard Universal PCI to USE Host Controller Intern FE 12 9 USB Enhanced Host Controller 2 Phest Controller Fami anced H st Controller
3. User Manual VVarnings and Precautions Precautions when using your Pro MicroScan A Keep camera away from the following e High temperatures and excessive humidity Direct sunlight or other heat sources e Dust Extreme vibration If the imaging sensor lens becomes dirty first try blowing dust particles from it Next use a lint free cloth or proper lens cleaning cloth to wipe the lens gently Only use approved lens cleaning fluids Never touch the lens with your fingers Do not allow the camera to come into contact with water or any other liquid If water or a foreign substance should get in the camera unplug the camera immediately and do not attempt to plug in until after a long period of time to allow for drying This does not necessarily mean it will work again Do not open the camera case or attempt your own repairs Internal components may create risk of electrical shock or fire There are no user serviceable components inside Clean the outside of the camera by wiping with a clean dry cloth Never use harsh or abrasive cleaners or organic solvents on the camera or any of its parts If you notice smoke or a strange smell coming from the camera immediately unplug the camera and consult an authorized dealer User Manual System Requirements PC running either Windows gt 2000 or XP Professional SP4 XP Professional SP2 are installed when shipping No working if specifications up to reach of above after shipment A
4. 1600X1200 2048X1536 2720X2048 Hardvvare 2M pixels 3 2M pixels 5 6M pixels Frame Rate lt 20frames sec 10frames sec Depend on the PC 1600X1200 2720X2048 lt 15frames sec 2048X1536 1600x1200 Video Mode 1024x768 2048X1536 2720X2048 800 x 600 1024x768 1360x1024 640 x 480 Dynamic Range 62dB 75dB 75dB Wave Length nm 400 650nm IR Cut added Exposure ERS Electronic Rolling Snap White Balance Automatic Advanced Manual Auto exposure Automatic Advanced Manual Image Output USB2 0 480Mb s Power Supply USB2 0 5 1 5 Programmable Control VVorking 309C 70 C Temperature USB Cable USB cable length 2 5m Accessories Included Output data RGB24 Direct Show and Twain interface Driver support Direct Show and Twain Software Image software MiniSee Operating System Hee OAN Standard image Condition I Windows 2000 Me XP SP2 SP3 2003 Vista 2008 32Bit system User Manual MDC140BW 5930 2 3 6 5HmX6 5um 0 05 in condition 1 1360X1024 1 4M pixels 12frames sec 1360X1024 1360X1024 680 x 512 2x2BIN 340 x 256 4x4BIN 80dB Image size exposure time brightness gain Gamma Correction color contrast Saturation 2 adaptors 023 2 to 030 023 2 to 030 50 one each TS M1 stage micrometer available for option at extra cost Advanced Image processing software ScopePhoto available for option at extra cost Use a pattern box luminance 70
5. 6cd m2 color temperature of 3200K halogen source as a subject Pattern for evaluation is not applicable Use a testing standard lens with CM500S t 1 0mm as an IR cut filter and image at F5 6 The luminous intensity to the sensor receiving surface at this point is defined as the standard sensitivity testing luminous intensity User Manual VVarranty OPLENIC Three Year Limited VVarranty OPLENIC warrants its products to be free from the date of purchase this product for three year OPLENIC will repair or replace such product or part thereof which upon inspection by OPLENIC is found to be defective in materials or workmanship As a condition to the obligation of OPLENIC to repair or replace such product the product must be returned to OPLENIC together with proof of purchase satisfactory to OPLENIC All returns must be accompanied by a written statement setting forth the name address and daytime telephone number of the owner together with a brief description of any claimed defects Parts or product for which replacement is made shall become the property of OPLENIC The customer shall be responsible for all costs of transportation and insurance both to and from the factory of OPLENIC and shall be required to prepay such costs OPLENIC shall use reasonable effort to repair or replace any accessory covered by this warranty within thirty days of receipt In the event repair or replacement shall require more than thirty days
6. OPLENIC shall notify the customer accordingly OPLENIC reserves the right to replace any product which has been discontinued from its product line with a new product of comparable value and function License Agreement The software and accompanying documentation are protected by the International copyright laws Any use of this software in violation of copyright laws or the terms of this agreement will be prosecuted to the best of our ability OPLENIC authorizes you to make archival copies of this software for the sole purpose of back up and protecting your investment from loss Under no circumstances may you copy this software or documentation for the purposes of distribution to others You may not distribute modify adapt translate reverse engineer recompile disassemble or otherwise attempt to discover the source code of the Software Any information supplied by OPLENIC or obtained by you as permitted hereunder may only be used by and may not be disclosed to any third party or used to create any software which is substantially similar to the Software
7. User Manual Pro M croScan Microscope Digital Camera BASIC USER MANUAL Version 3 0 USB 2 0 CAMERA User Manual CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO 7 8 THE Sac 7 55 5 SHOCK DO NOT 2 RVICEABLE PARTS INSIDE G 1 FIED OPLENIC SERVICE PERSONNEL REMOVE C vine REFER SERVICI The lightning flash with an arrowhead symbol within an equilateral A triangle is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to A alert the user of the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING TO AVO ID THE RISK OF FIRE OR ELECTRICAL SHOCK NEVER EXPOSE THIS PRO DUCT TO WATER OR OPERATE IN AHIGH HU MID IT YEN VIRONMENT Keep camera away from the following High temperatures and excessive humidity Direct sunlight or other heat sources Dust Extreme vibration If the camera lens becomes dirty first try blowing dust particles from it Next use a lint free cloth or proper lens cleaning cloth to wipe the lens gently Only use approved lens cleaning fluids Never touch the lens with your fingers Do not allow the camera to come into contact with water or any other liquid If water or a foreign substance should get in th
8. e camera unplug the camera immediately and do not attempt to plug in until after a long period of time to allow for drying This does not necessarily mean it will work again Do not open the camera case or attempt your own repairs Internal components may create risk of electrical shock or fire There are no user serviceable components inside Clean the outside of the camera by wiping with a clean dry cloth Never use harsh or abrasive cleaners or organic solvents on the camera or any of its parts If you notice smoke or a strange smell coming from the camera immediately unplug the camera and consult an authorized dealer User Manual Trademark and Copyright information COPYRIGHT 2008 OPLENIC All rights are reserved No part of this document may be photocopied reproduced or translated to another language vvithout the prior vvritten consent of OPLENIC The information contained in this document is subject to change without notice OPLENIC shall not be liable for errors contained herein or for consequential damages in connection with the furnishing performance or use of this material Microsoft and Windows are U S registered trademarks of Microsoft Corporation Welcome Thank you for buying OPLENIC Pro MicroScan high resolution USB2 0 camera We Suggest you spend a few minutes carefully reading this user manual before installing and using your camera Please keep this user manual in a safe place for future reference
9. ese conditions you should uninstall and unplug as many other USB devices as possible This should help to rule out the above and eliminate possible conflicts with other cameras If you are using an extended USB cable please make sure the cable s bandwidth is good enough to support High Speed USB 2 0 standard Once the camera is not working well please remove it Image Preview Capture Problems If you have installed driver and you get a black screen with DirectShow Capture Check the setting of PC display mode make sure that s on 32Bit true color If you can preview the image but can not capture it Camera icon is gray Installing the DirectX9 0 or later version Frame rate slow amp color noise on the screen Video Mode use smaller size video mode will get faster frame rate video Integration time luminous intensity setting longer Integration time and brighter illumination will make the frame rate faster If you have any other problems please visit our website to get help information http www oplenic com support asp http vvvvvv oplenic com faq asp Technical Data Sheet Pro MicroScan SkopKam digital camera FOR microscope Model MDC200 MDC320 MDC560 Part Number 5870 5910 5920 Sensor Size 1 3 1 3 1 2 Pixel Size 3 2umX3 2um N A N A Sensitivity 7 A AR v lux sec 550nm 0 45 in condition 1 0 4 in condition 1 0 45 in condition 1 Max Resolution
10. he camera name below Live capture on the bottom of start page If you do not see the start page you may find it from Help gt Show Start Page 3 Connect the camera to the microscope and turn on the light Please make sure your light system has the option of a BLUE LIGHT FILTER For the CCD to view properly you would need light color temperatures around 5600K 6000K 4 Setting the white balance Empty the stage so it would be viewing an empty field Then set the white balance by going to Setup Video source property auto white balance 5 Capture the image Press ES to capture image minisee File View Options Capture Settings Help A b Ni co 35 MH l Q dm YO Folders Refresh Icons Sort Pause Hope Copy Capture Auto MiniSee tool bar iz d A Gir 50 CA Pizel wilo vl ok MF v F IF e ScopePhoto tool bar 6 Capture the Video Settings Help Capture To Clipboard Ctrl1tC Capture a Frame Auto Capture Start Capture More about using the software please see HELP of the software User Manual Trouble Shooting WARNING Please do not attempt to open the camera case There are no user serviceable parts inside USB Device Conflicts When there are a number of USB devices installed at the same time unexpected errors can arise The cause can be insufficient available USB bandwidth or possibly too much combined current being drawn by USB devices To test for th
Download Pdf Manuals
Related Search
Pro MicroScan pro-microscan
Related Contents
Transmisores inalámbricos de humedad relativa/temperatura Les membres du Collectif pour une transition citoyenne AbeBooks/Iberlibro Search Web Services End User Guide HEM-7300 e Moen Felicity TS243BN User's Manual Home Decorators Collection 2826200410 Instructions / Assembly Impex ADI-5100-I User's Manual データシート ONKYO TX-NR929 Copyright © All rights reserved.