Home
The Dri•Bank® Container with Atacama™ or
Contents
1. 2 0mL microcentrifuge tubes i e Eppendorf tubes install insert provided Close the container by snapping the buckle over the front until a snap is audible When this occurs the box is closed and sealed The Drie Bank Container User Manual rev 2 Maintenance Depending on use as well as the environment of the operating conditions the container is used in will determine the frequency of visually checking the cartridge If Used dally it is recommended at the end of each workday to note the color of the cartridge beads Once more than half gt 50 of the beads have changed to a very light blue color it is time to order a replacement cartridge At this stage your cartridge will continue to function for about another week TROUBLESHOOTING Does not close Check to make sure the container gasket is seated properly around the whole container and not bulging or twisted anywhere If so correct as need including apply light pressure to move o ring back into slot for it fo seat correctly Close normally Cartridge does not lock into place Check to make sure that the o ring is properly seated in the cartridge groove If not apply light pressure to re seat o ring into groove Make sure there are no obstructions and apply firm even pressure and twisting to install the cartridge Molecular signal lost Prior to storing tissue of interest for a particular assays it is recommended to perform pilot runs in triplicate to ensure
2. SOLE AND EXCLUSIVE WARRANTIES AND ARE IN LIEU OF ALL OTHER REPRESENTATIONS GUARANTEES AND WARRANTIES WHETHER EXPRESS IMPLIED ORAL WRITTEN STATUTORY OR OTHERWISE WITH RESPECT TO THE PRODUCTS INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE MERCHANTABILITY NON INFRINGEMENT RESULTS AND WARRANTIES ARISING BY CUSTOM TRADE USAGE PROMISE EXAMPLE OR DESCRIPTION ALL OF WHICH ARE EXPRESSLY DISCLAIMED Warranty Return Procedure Customer must notify IBT in writing of all claims for defective Products within 30 days after Buyer s receipt of the Products and will reasonably cooperate in IBT s investigation of all warranty claims After IBT s review of such written notice IBT at its sole discretion may provide a Return Material Authorization RMA to Customer IBT may refuse any Products not timely notified or lacking an RMA provided by IBT Customer will properly clean and rinse the Products removing all biological chemical radioactive and hazardous residue IBT may require Customer sign and deliver a properly completed certificate of decontamination prior to returning any Products Then Customer may return the allegedly defective Products to IBT with all costs prepaid by Customer Returned Products must include the following information Customer name and address IBT shipping order number number and date of invoice IBT RMA Number and written explanation of reason for return All replaced parts will beco
3. The Drie Bank Container User Manual rev 2 Inclined Biomedical Technologies IBT LLC The Drie Bank Container with Atacama or Afacama C Cartridge The Drie Bank Container User Manual rev 2 Table of Contents Limited Warranty and Limitation of Liability css 3 FR PO Ucar ar iene ronrs A aera tesco is ed ooeeaenaateeent onan 4 In Warranty Repairs and Replacement cccceceeeeeeeeeeeeeeseeaneenens 4 Non Warranty Repairs and Replacement cccccecccseeeseeesseeeens 4 NUS 1S CCS OX rrara a a aA ING OCMC HIGH a2aveaqates ienteate acces teetacecee ceca eran eee eee OPEO Bererer mentee cert ee eer a rer renee ree teen neore me cere rene cree rn rere 6 MGa NZNO US e TE O A E E E EO Mantenan eaa Goauiiiuiat mtaubieebiiantatavennasds 7 Troubles MO OEING sanns a acaesneiaxieeseanianee 7 SPEC CAUNOMS acca ceactmenscnsisentaaateatansnausmipaptaseensenseeseuasaeamaleeoen 8 The Drie Bank Container User Manual rev 2 Limited Warranty and Limitation of Liability IBT warrants to Customer that a Products supplied by IBT will be free from defects in material and workmanship for 30 days from date of shipment Warranty Period and b title to all Products will pass to Customer as provided herein free and clear of any security interests and liens Warranties are made only to Customer and are not transferable and do not extend to the benefit of any other person or entity THE FOREGOING WARRANTIES ARE IBT S
4. UES LOST OR DECREASED USE OR PRODUCTION COVER DOWNTIME LOSS OF GOODWILL THIRD PARTY The Drie Bank Container User Manual rev 2 CLAIMS OR FOR ANY INDIRECT SPECIAL INCIDENTAL EXEMPLARY CONTINGENT CONSEQUENTIAL OR PUNITIVE DAMAGES OR LOSSES OF ANY TYPE OR KIND REGARDLESS WHETHER OR NOT I SUCH CLAIMS ARE BASED ON CONTRACT TORT INCLUDING NEGLIGENCE WARRANTY PRODUCT LIABILITY INDEMNITY CONTRIBUTION STRICT LIABILITY OR ANY OTHER LEGAL THEORY Il THE CLAIMS DAMAGES OR LOSSES ARE FORESEEABLE OR Ill ADVISED OF THE POSSIBILITY OF SUCH CLAIMS DAMAGES OR LOSSES Repair All products returned for warranty or non warranty repair should be accompanied by the following your name company s name address telephone number and proof of purchase Additionally please include a brief description of the problem or the service requested Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Inclined Biomedical Technologies LLC In Warranty Repairs and Replacement Please read the warranty statement and check your product thoroughly before requesting repair During the warranty period and defective product can be returned to IBT for an exchange for the same or like product In Warranty repair and replacement units can be sent to IBT see address below Non Warranty Repairs and Replacement Non Warranty repairs should
5. ability and ruggedness Each DrieBank container sold comes with its own Afacama cartridge to be installed and replaced when necessary The specially designed Afacama C cartridge is sold separately Functions as the normal Atacama cartridge with the added bonus of also adsorbing CO2 and volatile organic compounds VOCs The units have been designed so they are stackable large on top of large and small on top of small for up to five units OPERATIONS Initializing For first time use remove the DrieBank container and Atacama cartridge from their respective bags Check to make sure the beads seen through the Atacama cartridge are mainly dark blue If they are not and most of the beads are very light blue or beige have it returned for replacement Otherwise with the Drie Bank container closed insert the cartridge into the opening on the top of the container and twist the cartridge until seated with the alignment marks Once this has occurred check to make sure the cartridge is level with the container and there is no buckling which would prevent a hermetic seal After all this has been completed the container is now ready to be used for drying and or storing samples in multiple formats Use To open a closed container push down the front snap closure This will cause the container to pop open slightly If storing samples on standard 75mmx25mmx lmm microscope slides insert and remove as normal If storing 0 5
6. be sent to IBT Contact IBT for current repair and replacement rates Inclined Biomedical Technologies Inc d b a DriBank Labs PO Box 24392 Minneapolis Minnesota 55424 USA info dribanklabs com 844 599 1472 www dribanklabs com The Drie Bank Container User Manual rev 2 Inside the Box 1 The Drie Bank container 2 Atacama or Atacama C cartridge 3 The Drie Bank container latch 4 Locking port not shown 5 Membrane 6 Microscope slide retaining cushion not shown 7 Silicone rubber mat not shown 8 Adapter for microcentrifuge tubes not shown The Drie Bank Container User Manual rev 2 INTRODUCTION The Drie Bank container is a specially designed storage unit that can a store fresh frozen tissue sections on microscope slides at room temperature for up to 6 months without the need for chemical preservation b be a supplement to hold temperature sensitive tissue sections in freezers cC dry out purified samples DNA RNA proteins etc and store at room temperature for 3 months or longer d dry and store unfix biopsy samples for shipment NOTE the container rapidly dries the sample out while maintaining critical biomolecule integrity DNA RNA and proteins and cellular morphology or e store reagents and chemicals that are sensitive to both light and moisture This product has been designed with scientists and technicians in mind for ease of use reli
7. both the tissue and biomolecules of interest are compatible with the DrieBank container unit or refer to our online database for a list of tissues and biomolecules currently known to be compatible with our storage system Not Available at this Time If it is known that your tissue and or biomolecule s of interest is compatible check the seals of the box by holding it up to the light Any seal malfunction can easily be identified this way i e one can see light passing through the box where it should not Verify there is nothing obstructing the gasket to prevent a proper seal and re try again If problem persist contact IBT for technical support The Drie Bank Container User Manual rev 2 SPECIFICATIONS Environmental Container storage temperature 80 C to 80 C Container operating temperature 80 C to 80 C Container storage humidity O to 100 RH Atacama cartridge operating humidity 0 to 100 RH Atacama C cartridge operating humidity O to 100 RH Dimensions Container 9cm x 14cm x 5cm Atacama Cartridge 6 5cm x 1 3cm Atacama C Cartridge 6 5cm x 1 3cm Weight Container 200g Atacama Cartridge 50g Atacama C Cartridge 50g Not Required Power Refrigeration Fixatives 2014 Inclined Biomedical Technologies LLC All Rights Reserved DrieBank Atacama and Atacama C are trademarks of Inclined Biomedical Technologies LLC Drie Bank is a registered trademark 8
8. me the property of IBT CUSTOMER S SOLE AND EXCLUSIVE REMEDY AND IBT S SOLE LIABILITY ARISING OUT OF OR RELATING TO PRODUCTS OR ANY BREACH OF WARRANTY IS LIMITED TO AT IBT S OPTION AND EXPENSE A IBT REPAIRING DEFECTIVE PRODUCT B IBT REPLACING DEFECTIVE PRODUCT OR B IBT CREDITING CUSTOMER S ACCOUNT FOR AMOUNTS PAID WITH RESPECT TO DEFECTIVE PRODUCTS SUCH REPAIR REPLACEMENT OR CREDIT WILL CONSTITUTE FULFILLMENT OF ALL LIABILITIES IN RESPECT OF SUCH PRODUCTS In no event will IBT have any obligation for a warranty claim as the result of i normal wear and tear ii damage abuse misuse alteration tampering fault or negligence caused by anyone other than IBT iii use of the Product in a manner for which it was not designed v causes external to the Product and vi improper storage and handling of the Product If IBT provides repair services or replacement parts that are not covered by this warranty Customer will pay IBT at IBT s then prevailing rate of the Products IBT PROVIDES PRODUCTS ON AN INDIVIDUAL PER ITEM BASIS TO THE FULLEST EXTENT ALLOWED BY LAW IBT S TOTAL LIABILITY FOR ANY CLAIM LOSS OR DAMAGE ARISING OR RELATING TO ANY PRODUCT S OR THE PERFORMANCE OR BREACH OF THIS AGREEMENT WILL BE LIMITED TO THE AMOUNTS THAT IBT ACTUALLY RECEIVED FROM CUSTOMER FOR THE APPLICABLE ITEMS TO THE FULLEST EXTENT ALLOWED BY LAW IN NO EVENT WILL IBT BE LIABLE TO CUSTOMER FOR LOSS OF ACTUAL OR ANTICIPATED PROFITS OR REVEN
Download Pdf Manuals
Related Search
Related Contents
Emulation Manual - Elation Professional SWE-0216G3 Real-Time Weather Data Access Guide icon-red 取扱説明書 - ご家庭のお客さま/大阪ガス Roper Photometric User's Manual CX4 Camera User Guide Programme de formation Cnet CNP410S print server garantie à vie Copyright © All rights reserved.
Failed to retrieve file