1.  a stable interferogram is another indication that the HWG accessory is  ready for measurements  An insufficiently cooled detector will produce a low and unsteady signal  The    PN 350 048100 01 Page  3    red LED light indicates the accessory is not ready for use  If the red LED is illuminated during use check  that the detector Dewar is filled with liquid nitrogen        Place the Diffuse Gold Reference on the sample window to maximize the light level in the sphere  The  gain of the IntegratIR is set to around 4 5 V with open aperture           PN 350 048100 01 Page  4    Adjustment    The accessory has been aligned and tested to ensure that it performs to specifications and no additional  alignment is necessary     Sample Preparation    Sampling with the IntegratIR is as easy as placing the sample on the optical window on the top of the  accessory  For plastic sheets  painted test panels and other flat samples the reproducible sample  positioning has to be assured  If the sample does not lay flat under its own weight  a small weight could  be placed on the sample to press it against the window or open port if the window plate is removed to  aid in the accurate and repeatable sampling  Other materials  such as powders and pastes can be  directly placed on the ZnSe window  The choice whether to use the window or to place the sample  directly on the integrating sohere depends on the type of sample  The window is sealed using epoxy  compound  and can be cleaned preferably with
2.  alcohol or with acetone in the case of more difficult  samples  In all cases  the accessory is measuring the reflected light  thus transparent materials  films  produce very small signal  In certain cases a reflective mirror can aid in returning the near infrared light  to the sphere detector  Please note that the reflectance of the ZnSe affects the measurement  the  reflected light is added to the reflectance of the sample  For absolute reflectance measurement place  the sample directly on the sample port of the sphere     Use Gold Reference placed on the window for background spectra and for interferometer alignment     IMPORTANT NOTE  After use please replace protective cap to avoid damage or contamination to gold  surface     Samples need to be presented to the spectrometer in an optically uniform and reproducible fashion to  obtain the same spectrum every time  Parameters that have significant effect on the samples are  particle size and distribution  crystallinity  phase  melted or solidified oils for example have very  different spectra    compression  temperature  especially water containing samples  and other physical  or chemical differences     PN 350 048100 01 Page  5    Sample Reference Selection Mirror    On the front of the IntegratIR module there is a knob that selects the sample or reference positions     IMPORTANT NOTE  Please move the selector in between the SAMPLE and REFERENCE positions only   When the selected positions are reached  it will click in pla
3. 53719  Printed in  the United States of America  All world rights reserved  No part of this  publication may be stored in a retrieval system  transmitted  or reproduced in  any way  including but not limited to  photocopy  photograph  magnetic or  other record  without the prior written permission of PIKE Technologies  Inc     Address Comments to   PIKE Technologies  Inc     6125 Cottonwood Drive  Madison  WI 53719    Phone  608  274 2721  Fax  608  274 0103  E mail info piketech com  Web Site www piketech com    Jan  1  2012    Contents    Introduction  Unpacking Your Accessory  Packing List  Installation  MCT Liquid Nitrogen Filling and Stabilization  Adjustment  Sample Preparation  Sample Reference Selection Mirror  Measurement without Substitution  Typical Spectra  Precautions  Replacement Parts and Options  APPENDIX    CO  CO  CO  YJ  M  DD  OW  UT  WW  WI  NI N  PP    Introduction    IntegratIR    series Mid Infrared Integrating Sohere module is a compact sampling accessory for  measuring the diffuse reflectance of a wide variety of solid materials  The IntegratIR    module features a  3  high reflectivity gold coated integrating sphere and a high speed  low noise liquid nitrogen cooled  Mercury Cadmium Telluride  MCT  detector with transfer optics and interface electronics  The  IntegratIR    fits in the sample compartment of the FTIR spectrometer and connects to the internal  detector port of the spectrometer  The 18 mm diameter opening on top of the integrating spher
4. Installation and User Guide       TECHNOLOGIES  Specticecopie Creativity       j PE       IntegratIR     Mid IR Integrating Sphere    The information in this publication is provided for reference only  All  information contained in this publication is believed to be correct and  complete  PIKE Technologies  Inc  shall not be liable for errors contained herein  nor for incidental or consequential damages in connection with the furnishing   performance  or use of this material  All product specifications  as well as the  information contained in this publication  are subject to change without notice   This publication may contain or reference information and products protected  by copyrights or patents and does not convey any license under the patent  rights of PIKE Technologies  Inc  nor the rights of others  PIKE Technologies  Inc   does not assume any liability arising out of any infringements of patents or  other rights of third parties    This document contains confidential or proprietary information of PIKE  Technologies  Inc  Neither this document nor the information herein is to be  reproduced  distributed  used or disclosed  either in whole or in part  except as  specifically authorized by PIKE Technologies  Inc    PIKE Technologies  Inc  makes no warranty of any kind with regard to this  material including  but not limited to  the implied warranties of merchantability  and fitness for a particular purpose    Copyright 1991 2012 by PIKE Technologies  Inc   Madison  WI 
5. ce to produce reproducible repositioning of  the gold mirror inside the sphere  There are two different ways of using the Mid IR IntegratIR  The  mirror can be left in the SAMPLE position and the background can be measured first using the Gold  Reference supplied with the IntegratIR  After the background is collected  the reference is substituted  with your sample and the spectrometer should collect the sample spectrum  In this mode the  Sample Reference Mirror should be left in SAMPLE position  This is called the substitution method   because the reference is substituted with the sample     Measurement without Substitution  The IntegratIR has another measurement mode  The Taylor method of measurement is made by    LEAVING THE SAMPLE on top of the sphere at the sample port and moving the Selector Mirror to  REFERENCE position to measure the background and back to SAMPLE measuring the sample spectrum     PN 350 048100 01 Page  6    Typical Spectra    The spectral results using the IntegratIR depend to some degree on the spectrometer it is used with   Source intensities  shape of the infrared beam  the beam splitter characteristics vary from bench to  bench  thus the single beam spectra could be slightly different  Using the Gold Reference or other well  characterized highly reflective standard and ratioing against this background corrects for the individual  throughput characteristics of the spectrometers  A typical single beam spectrum and a zero reflectance  line are shown b
6. ched to the  15 pin D connector in the sample compartment of the spectrometer  Select the appropriate source   optical path and detector  Please consult the software manual provided by the spectrometer  manufacturer concerning how to perform the detector and source selection  For best results please use  parameters in Appendix A     To connect the IntegratIR  please turn off the spectrometer  After the accessory is connected  power up    the instrument     The accessory can be directly purged via the purge port on the front panel     MCT Liquid Nitrogen Filling and Stabilization    Fill the MCT detector with liquid nitrogen using the funnel included with the accessory     WARNING  Wear safety goggles and protective clothing when handling liquid nitrogen  Exposure to  liquid nitrogen will cause severe skin or eye injury     Pour a small amount of liquid nitrogen into the funnel and wait for it to drain into the Dewar of the  detector  Add additional small amounts of liquid nitrogen until the detector is filled  Allow the detector  to stabilize for about 10 minutes and then top it off with a final amount of liquid nitrogen to completely  fill the liquid nitrogen Dewar  A lit green LED light indicates the Dewar contains liquid nitrogen and is  beginning the detector cooling process or is sufficiently cooled  It is not an indication that the accessory  is necessarily ready for use  Be sure to wait a 10 minute equilibrium time after the Dewar has been  completely filled  Observing
7. e is the  sample window through which the sample is illuminated  The samples are placed horizontally on the    sphere for direct illumination     An additional sample plate is available with a built in ZnSe window  Using the ZnSe window as a  sampling port  powders can also be measured on the top of the integrating sphere  The window is  bonded and sealed to protect the sphere from corrosive materials and contamination  In addition to the  main function of diffuse reflectance measurements  the IntegratIR can also be used to measure diffuse  transmittance  On the illumination port side of the device there is a standard 2   x3    slide position which  allows thin samples such as polymer films or other thin sheets of materials to be brought into the  infrared beam  The integrating sphere  positioned very close to the partially transmitting  partially  scattering sample  collects all infrared light emerging from the sample  The gold plated sample slide  included with your IntegratIR serves as a sample mounting surface and can also serve as an aperture  controlling the beam for minimum background scatter     rr Detector Cable Connection           Temperature  Indicators   gt     Detector Dewar    Sample Reference    Position Knob  E Diffuse Gold Reference    Purge Tube Connector with Protective Cap    Figure 1  Components of the IntegratIR Accessory    PN 350 048100 01 Page  1    Unpacking Your Accessory    In order for you to quickly verify receipt of your accessory  we have incl
8. elow     The enclosed spectrum was recorded at 4 cm    resolution showing ambient water vapor and CO    Purging the sample compartment will also reduce this effect for increased spectral reproducibility in the  water vapor and CO  regions     Art ary ums    Absorbance       0 8 Y __   ____e __ 9     _ o__ 0 0 0 1 Y __    8 ___   _ 0  _ g __ RU 0 0 8       __ a  _ 6 0       0         Figure 2  Single beam energy of the IntegratIR  Typical noise level around 1800 2200 cm    should be less than  900 uAbs RMS     PN 350 048100 01 Page  7    Precautions    In order to provide the maximum signal in the infrared  with the minimum spectral interference  the  mirrors used in this device are gold coated  Since the coatings are soft  care must be taken to avoid  damage  Normally  these mirrors will not need cleaning  since they are contained within the housing of  the accessory  If they do need cleaning  they may be gently wiped with a lint free  abrasive free cloth   such as lens tissue  or with a camel hair brush  Under no circumstances must the mirrors be rubbed with  paper products such as    Kleenex    since this may produce scratching of the mirror coating     Replacement Parts and Options    Part Number Description   048 0100 Sample Plate with 18 mm x 2 mm ZnSe Window  048 3000 Diffuse Gold Reference   APPENDIX A    Recommended Measurement Parameters Range for FT IR Spectrometers    Wavelength Range  5000 to 600 cm      Velocity  select appropriate for MCT detector for your FTIR 
9. spectrometer  Aperture  Open   Resolution  4 or 8 cm      Number of scans  64    NOTE  Before installation  please turn the FTIR Bench off  In order to install the IntegratIR  the detector  cable has to be connected to the FTIR spectrometer electronics  Please consult your FTIR User Manual  for instructions about connecting a sample compartment accessory INSTALLATION OF IntegratIR  DETECTOR CABLE     PN 350 048100 01 Page  8    PICE    TECHNOLOGIES    Spectroscopic Creativity    6125 Cottonwood Drive   Madison  WI 53719 5120    608  274 2721  TEL     608  274 0103  FAX   sales piketech com   www piketech com    
10. uded a packing list  Please  inspect the package carefully     Packing List    IntegratIR User Manual IntegratIR Accessory Detector Cable    PN 350 0481000 01 PN 048 10XX 048 3000  Quantity 1 Quantity 1 Quantity 1    Gold Reference Mirror with Liquid Nitrogen Funnel Camel Hair Brush  Protective Cap Quantity 1 Quantity 1    PN 048 3000    Quantity 1       Spatula  Quantity 1    Y       PN 350 048100 01 Page  2    Installation    Before installation  make sure the spectrometer is working in the mid infrared region without the  IntegratIR  Please consult the manufacturer of the FT IR spectrometer for proper operation  This may  involve replacing the beam splitter and source to optimize for the 4000 to 600 cm    wavelength region of  the IntegratIR  It is advisable to perform an alignment of the interferometer before inserting the  IntegratIR into the sample compartment  Each IntegratIR unit is custom manufactured to interface with  a specific model FTIR Spectrometer  Operation with a different model may require a factory conversion  to be done by PIKE Technologies  Place the accessory in the sample compartment of the spectrometer   The pin mounting of the accessory plate assures the alignment of the accessory relative to the beam  coming from the spectrometer  Connect the detector cable to the spectrometer     CAUTION  Make sure power to the spectrometer bench and the IntegratIR are off before       y connecting the detector cable  For ThermoFisher instruments use the cable atta
    