Home
Personal Archive User Manual
Contents
1. N N GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 GenTegra Two GenStore Archives shown mounted on optional table stand GenTegra Contents GEROAN e E E SES 4 GINS IIMA eos a a E E E T 4 sdlety FC CAUMONS sesss rennene EEE EEEE ORE 4 Contac US ae E E E ee ee ee 5 Cabinet Properties and Description ccceccececececeeeeeeceeeeeeeeeeeteeeeeeeeeseeeeeeas 6 Cabinet Properties and Function cccccccceccseeeeeteeeceeeteeeeeeeeeetseeseeeeeeeaeeeeas 6 Cabinet Descrip HON cenacanteanactean asanaasgacensncueanlencsanite AE EEEE 7 installation and Set p oats ssacresd ect rncarenaieanapninerna niet ncisintactscelouwwnsuaevsnaaeaadiiceuceenaanesmemsnsene eat 9 ne See cle 6 ieee ee eee ee eee ere eee ee ee eee 9 Installation of Cabinet and ACDH cccccccecccsececceeeeee cess eeseeeeeeeeeeseeesaeeeaeeeas 9 EICCIIGAll CONNECTOR sssicas2cncxexnacecosenstisacanecacadnandestepeciciededaesverseasecndgeneievarssbesteseets 10 Nalidrs iG 2 9 q c feet eee ee eee eee eee ee eee ee 10 Installation of Optional Wireless Temperature and Humidity Monitor 11 E RICER a E A EE AN EE TEN AE A A T 12 Installation of Optional 2D Barcode SCaNnnel c ccc eeee cece eee eee eee e eee enees 12 cpe 912 2 6 eee ren ee enone ee on nee 13 ADENO Geo ae ee ee ee eee ee ee ee eee eee 14 GETTING STARTED Congratulations on your
2. Cabinet with the ACDH unit and for liquid draining purposes An installed and pre configured humidistat ensures that before relative humidity exceeds 40 the dryer will turn itself on automatically Once relative humidity has reached about 30 the dryer will switch off The inlet port for compressed air is located on the back of the cabinet It accepts supplied standard pneumatic tubing or an alternative with an outer diameter of 6 35 mm 4 inch Cabinet Dimensions Height 888 mm 36 in Width 1054 mm 41 5 in Depth 762 mm 30 in Weight without plates 150 kg 330 Ibs Performance Specifications Relative Humidity Control 30 10 ACDH Supply voltage 110V 120V single phase 60Hz or 230V single phase 50Hz depending upon your country Full Load Current 5 ampere maximum Fuse Size 5 x 20 mm 10A 250V slow blow GenTegra i CABINET DESCRIPTION This section describes the Cabinet s appearance description that follows Use this image as a guide to the 7 i sk es e a ES e y The Cabinet includes the following main parts 1 Cabinet framework 2 GenTegra GenStore Archive storage rack 3 Front panels Rear view of GenStore Archive and pneumatic ports for GenStore Archive air dehumidification system 4 Dry Air inlet 4 5 Connector to ACDH unit GenTegra View 1 of air compressor dehumidifier unit 1 Air Inlet Fan Warning do not bl
3. purchase of the GenTegra GenStore Archive Cabinet and ACDH the Cabinet The Cabinet together with the GenTegra GenPlates provides a safe and efficient room temperature solution to long term biosample storage This manual serves as a reference for both the laboratory technicians who use the Cabinet and the service technicians who maintain it USING THIS MANUAL As a proud owner of the GenTegra GenStore Archive Cabinet and ACDH it is important that you read this entire manual which covers installation operation and maintenance of the Cabinet Further GenTegra strongly recommends that only trained service technicians perform repairs to the Cabinet SAFETY PRECAUTIONS The ACDH uses compressed air and high voltages Throughout this manual the Safety icon left indicates when you must follow a procedure to avoid a safety hazard such as shock or other injury Read this section for precautions related to installation grounding maintenance and repair electrostatic damage and product protection Failure to follow the guidelines here could invalidate any guarantees and warranties m Installation Follow the instructions in this manual exactly to make sure your Cabinet functions properly m Maintenance and repair m Only trained and qualified repair technicians should perform repair tasks m he Cabinet must be disconnected from voltage while repair or maintenance is conducted m All safety or other fixed covers must rem
4. abinet under this table a Place the second cabinet on the floor b Raise the foot by turning the castor wheel clockwise so that the Cabinet can freely roll repeat with all 4 rollers U Down P c Attach the pneumatic tubing and sensor cord to this cabinet and the second ACDH d Roll the cabinet under the table ELECTRICAL CONNECTION To plug in your ACDH connect the power cord to an electrical supply of 110V 120V 1 phase 60 Hz power or 230V 1 phase 50Hz power depending upon your country CLEANING Once the Cabinet is installed and turned on clean its surfaces once to remove debris accumulated from transportation and setup Before cleaning the Cabinet read these guidelines m Use a clean soft lint free cloth suitable for clean room use m Use a cleaning product suited for painted steel surfaces Consult a product s manufacturer if you are unsure of a product s effects GentTegra m Avoid using harsh chemicals or abrasives m Wipe down the Cabinet surfaces with a damp cloth and appropriate cleaning product m Carefully wipe off all debris and biological material from GenPlate surfaces before they are placed in the Cabinet INSTALLATION OF OPTIONAL WIRELESS TEMPERATURE AND HUMIDITY MONITOR 1 The transmitter comes pre installed by GenTegra It rests vertically inside the back of the cabinet Transmitter Connection to Cabinet Mount Attachment to Cabinet 2 The receiver and software must be ins
5. ain in place while voltage is disconnected for maintenance or repair m No equipment spare parts that a user can replace are included with the Cabinet m Product and sample protection The Cabinet protects samples in the GenStore Archive storage rack only when operated under normal conditions with all doors closed GenTegra i CABINET PROPERTIES AND DESCRIPTION This chapter describes the physical properties of the Cabinet Study the information here before installing or working with the Cabinet CABINET PROPERTIES AND FUNCTION Included with this cabinet is a separate air compressor dehumidification ACDH unit that plugs directly into the GenStore Archive for power which provides a source of clean dry air to maintain humidity at or below 40 RH in most environments This unit generates compressed air and also removes moisture from that air Included tubing which attaches to the GenStore Archive cabinet pipes the conditioned air from the unit into the cabinet Additionally this unit contains a condensate drain outlet Depending on the quality of the compressed air supply certain amounts of liquids might be exhausted from this port These liquids can be disposed in several ways A collecting vessel can be placed underneath the port A PVC or Polyurethane hose can be attached to the port leading to a floor drain or laboratory sink A 10 foot length of standard tubing is included with the cabinet to connect the GenStore Archive
6. ock this fan at any time Please maintain a distance of 6 inches between the fan and the nearest object 2 Humidity Control Display View 2 of air compressor dehumidification unit 8 i Lal 3 Exhaust Fan Warning do not block this fan at any time Please maintain a distance of 6 inches between the fan and the nearest object 4 Plug to electrical outlet 5 I O switch for ACDH unit 6 Condensate Drain Outlet 7 Dry Air Outlet 8 Plug for humidity probe from Cabinet GenTegra l INSTALLATION AND SETUP SITE SELECTION Because of its connection to the ACDH unit the Cabinet generates a small but steady heat load The average laboratory or workroom adequately dissipates this heat load INSTALLATION OF CABINET AND ACDH The Cabinet may rest directly on a freestanding table which is capable of holding at least 500lbs To install the Cabinet take these steps 1 Remove the Cabinet from the packaging please note the feet will be down and the rollers up 2 Place the Cabinet on a firm level table away from airflow or if you purchased a ta ble from GenTegra on that table 3 Place the ACDH unit on the floor near the Cabinet 4 Attach the supplied pneumatic tubing 6 35mm to the inlet port on the cabinet and the outlet port on the ACDH 5 Plug the cord for the humidity probe into the back of the cabinet and plug the other end into the ACDH GentTegra 6 Itis also possible to roll a second c
7. talled on a computer at the installation site 3 Please refer to the enclosed User Guide for this system for detailed operating in structions 4 Insert the supplied software CD into your CD ROM drive on your computer and fol low the on screen directions to install 5 Attach the supplied antenna to the receiver Pointing it up is recommended Plug the attached cord into the receiver and your computer s USB port 6 When your computer indicates that it has found new hardware follow the wizard instructions to install the correct USB driver from the CD For detailed instructions on capturing humidity data please see p 3 6 thru 3 18 from the provided user manual for this system GentTegra MAINTENANCE The transmitter in the Cabinet operates on batteries which will need to be replaced pe riodically m To remove the transmitter from the cabinet loosen the 4 Philips head screws from the enclosure on the back to slide out the transmitter Then loosen the two screws on the back of the transmitter to remove the battery cover m Follow the detailed instructions on p 4 12 of the user manual for this system INSTALLATION OF OPTIONAL 2D BARCODE SCANNER View the enclosed Quick Start Guide for more detailed instructions but what follows are a few key instructions 1 Ensure your computer is turned off before you connect the base to your computer 2 Toscan hold the imager directly over the barcode pull the
8. trigger and center the aiming beam on the barcode 3 The complete user manual is included on the CD provided with the 2D barcode scanner GentTegra CABINET OPERATION This section describes how to operate the GenStore Archive system including the ACDH unit The on off switch for the system is located on the back of the ACDH m To turn the system on press the switch to the position m To turn the system off press the switch to the O position m Leaving the switch in the position is required for automated humidity control 12 APPENDIX Electrical Safety The ACDH is tested as a Class 1 electrical device The correct fuse must be fitted at all times This along with other parts of the electrical system should be examined frequently for signs of damage 13 Gentlegra Should you have any questions or comments about the GenStore Archive Cabinet storage rack or GenPlates use the information provided here to reach the GenTegra staff GenT gre LLC 1061 Serpentine Lane Suite B Pleasanton CA 94566 Telephone 925 461 3010 8 00am to 5 00pm PST Monday Friday _ Email support GenTegra com
Download Pdf Manuals
Related Search
Related Contents
Samsung M1777N Užívateľská príručka Fiche Technique ECOLO`CLEAN Présentation Mode d`emploi et MTP-600 Series Modular Thermal Printers User Manual HARICOT RENIFORME EN PAPIER Réf. N°: 1620026 descargar folleto Monitor de atividades 24x7 Manual do Usuário TP afficheur LCD sur PICDEM2 2630 c Copyright © All rights reserved.