Home
007 User Manual
Contents
1. b For detailed voltage reading you may use a voltmeter in the multi port to check battery status even when the kit is off c The battery status indicator will rarely be completely illuminated as this is 14 5 volts Even if you are charging and do see this completely illuminated when you take the kit off charge the batteries will normalize and the meter will settle down a couple bars This is completely normal As long as you operate within the normal range your kit is charged as expected Do not allow water to penetrate the interior of the kit A little water on the dashboard will not harm the kit but submerging the electronics may damage the inverter beyond our capacity to service it Do not under any circumstance attempt to plug something into the kits inverter and turn it on if the kit has become water logged This kit generates electric current Always remember that water and electricity don t mix The solar panel s are sealed and may be exposed to water rain amp snow but to extend the life of these products we recommend only exposing the panels during the time you are charging the batteries or running the kit in daylight Periodic durations in variable weather conditions are acceptable but leaving the a Si folding panels exposed to the elements for extended periods weeks years will result in natural material fatigue When your case is being stored store the panel s inside with the case Keep your panels clean for the best p
2. During recharge a battery at 60 SDL is actually 40 discharged this is the value we need to use when figuring recharge time These formulas are average estimates There are potentially many other factors that can affect your calculations including battery age number of cycles it s been through Over time this will affect the performance of the battery and as such we can expect the time derived from this formula to expand To use these formulas you have to know how to find the Amperage Watts and Volts of whatever it is you want to run There are several online conversion calculators Look at the back of the device or the power adapter There will be a label that gives the INPUT Voltage and having this info allows you to find o Amps Watts Volts o Watts Volts Amps o Volts Watts Amps Perigee Power Solutions Solar Power Kit User Manual Warranty Perigee Power Solutions shall provide quality products at fair prices We personally test each component we use in our kits and maintain a process based upon fundamentals that verify we build our products right and that we built the right product If you ever encounter a problem with our products let us know as soon as possible We promise to work with you on a case by case basis to resolve issues if they should arise Limited Warranty Returns are accepted within 14 days of purchase for a refund Perigee Power Solutions warrants kits for 90 days against defects in workmanship for
3. interested in powering Note Puekerts Law is normally 90 While this provides better formula results we modify to account for additional unknown variables such as environment usage amp temperature This has proven to be more accurate in all of our field tests This simple formula calculates battery duration based on device amp draw amp inverter at no load We then account for the loss of power that is inherent with an inverter at full load The example below shows an LED lamp using 068A per hour plus the 201 kit inverter at 21A per hour Here s the break down a Battery Ah 85 Puekerts Law x b x total amp draw average of device amp inverter y gross time duration c y 85 avg inverter efficiency full load xy d xy 0 4 z Est run time 60 battery Safe Discharge Level a x 11 9Ah J4Ah 85 11 9 b y 41 0 11 97 29 41 03 c xy 34 87 41 03 85 34 87 d z 13 95 hours to SDL 34 87 40 13 95 This formula assumes a flat draw rate without variation To calculate a variable device we need to do more math first Here is the formula to calculate average amp per hour that considers max amp min draw Imax Tactive 3600 Imin 3600 Tactive 3600 Iavg Imax max amp draw from battery Tactive time in seconds drawing max amps Imin min amp draw from battery 3600 num of seconds on one hour Iavg avg amp draw per hour Example Imax 2A Tactive appro
4. our entire product line fully assembled kits and all devices manufactured expressly by Perigee Power Solutions Individual 3rd party components not assembled by Perigee Power Solutions are covered by our limited warranty through those respective manufacturer s Our warranty provides coverage for defects in manufacturing only and expressly excludes coverage for excessive wear and tear and or physical accidental abuse loss and theft Improper repair or warranty service performed by someone other than Perigee Power Solutions shall void this warranty Customer is responsible for return shipping charges Returns are processed by Perigee Power Solutions after receipt verification Returns must arrive in the original shipping box in condition new with all original components amp documents for refund consideration Customer agrees to use only reputable carriers capable of providing proof of delivery and insurance for the entire value of the shipment and agrees to bear all shipping and insurance charges and all risk of loss for the return product during shipment If any component of the returned product is missing or if the product is no longer sellable as condition new Perigee Power Solutions may in its discretion reject the entire return or choose to impose additional charges against the customer for replacement of missing component s Perigee Power Solutions shall not refund original shipping or handling charges and a 10 restocking fee derived from
5. the original purchase price is applicable to all refunds Please do not attempt to process returns from the store you purchased your kit Ship to Perigee Power Solutions 351 Green Ridge Road New Oxford PA 17350 Send any return related questions to sales perigeepower com Returns for purchases made on Amazon com may be processed via their return request system Shipping Damage Any damages incurred during shipping must be reported within 24 hours of receipt Be sure to inspect all packages for damage before signing for the package If damage is visible reject the shipment be sure the driver notes the damage and contact Perigee Power Solutions as soon as possible Perigee Power Solutions will file a claim with the shipper and ship a replacement upon return of the damaged item Perigee Power Solutions DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF WRITTEN OR IMPLIED WARRANTY OF THIS ITEM INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Our warranty is valid only at Perigee Power Solutions amp within the U S A Perigee Power Solutions Solar Power Kit User Manual Specs 1 Pelican Case 1150 e External Dimensions 9 25 L x 7 56 W x 4 38 H e Weight lt 7Ibs fully loaded with the following components 2 Power Ports e Solar panel input color coded amp keyed port e Auxiliary input color coded amp keyed port e 12 volt DC Power out standard cigarette lighter plug 3 Lower Case Compartm
6. components to augment the kits functionality visit our Accessory page Panel Expansions increases the kits solar recharge rate Dual Quad Delphi Daisy Chain Wiring Harness supports additional panels for models 007 301 AC Wall Adapter charge the from grid 14Ah max amp 28Ah and up Modular Battery Pack 201 swap use 301 101 007 use via multi port Panel Extension Cable 12 for models 301 007 30 ext for model 401 12V DC to 140W adapter for the 007 12V USB Adapter for charging your USB devices Oy al da Perigee Power Solutions markets their kits under provisional patent US61 384200 Thank you for your interest in Perigee Power Solutions n
7. e Power Solutions Solar Power Kit User Manual Step 2 Using 110 AC The 007 does not ship with an internal inverter but it does support the use of one Here are the options that allow you to use AC power with the 007 e External 140W MSW inverter 12VDC Port o Verify the inverter switch is in the off position if applicable o Insert a 12VDC 140W inverter accessory into the 12VDC port o With Main Power On plug your 140W device into the inverter o Turn the inverter switch on if applicable power your device o Turn off the inverter unplug when done e External 200W MSW inverter multi port o Verify the inverter switch is in the off position o Connect the 200W MSW inverter to the kits multi port o With Main Power On plug your 200W device into the inverter o Turn the inverter switch on power your device o Turn off the inverter when done Notes 1 If using a 12VDC port inverter model there may may not be an external on off switch on the inverter itself Most are just plug in and it s on it depends on the model on hand at the time of shipping 2 Turning the inverter off when not in use is recommended as a battery saving tactic Always verify the use of electronics with the manufacturer when connecting to a modified sine wave MSW 4 We also offer an external 180W pure sine inverter for use with sensitive electronics gt Perigee Power Solutions Solar Power Kit User Manual Step 3 Checki
8. ent e Battery space One Sealed Rechargeable 12Volt 7Ah e Electronics kit e Power Controller e Regulations point 14 5 Volts e Low voltage Disconnect 11 1V Volts e Low voltage Reconnect 12 5 Volts Microcontroller digital accuracy e Electronic protections Short circuit over current solar and load e Limits high voltage to protect battery 4 Dashboard e Internal DC port e Main power On Off Switch e LED Indicators reports battery state solar charging state and 12 volt output e Uniquely configured and color coded plug port for use with our e AC charge adapter for easy in home battery maintenance straight off the grid e Daisy chain connects multiple kits in parallel and recharge batteries from one source e Probe this port using a voltmeter to check specific voltage level _10 Perigee Power Solutions Solar Power Kit User Manual Notes aa Perigee Power Solutions Solar Power Kit User Manual OC Checklist Solar Panel Do Cables Continuity SSCS St ED II DEE o SyS Load Test 60W w Ext Inverte oo ooo Accessory USB AC Charger AUX Jumper eta o oS Battery I2VDO la ho AUX Multiport la Do Date Tested Initial Contact Info Email Sales perigeepower com or TechSupport perigeepower com Phone 443 375 3765 Sales amp Support More Information Look for our videos on YouTube and news on Facebook Links to both are available on our website Accessories For some additional
9. erformance A damp cloth is all that is needed to remove dust amp dirt We recommend using a non abrasive cloth that will not scratch the glass or a Si folding panel material when cleaning Air dry If batteries become damaged do not use them Normal use will not harm your batteries and we include a fuse to protect them from over current The fuse is a standard auto type fuse that if tripped will have a broken element that is visible when removed from the battery housing or the dashboard as is the case with the 007 Do not remove your battery from the protective and sealed housing provided by Perigee Power Solutions We manufacture a Gator cable that is designed to plug into the multi port and allow you to connect probes from a voltmeter to derive a detailed voltage reading on kits that just have a battery status bar Take care that you don t touch the two clips together when plugged into the multi port as this will blow the inline 7 5A ATC fuse If this occurs simply remove the fuse cover on the gator cable and replace with a 7 5A or 10A ATC fuse We manufacture accessories called Multi port Interface switches These vary in function from model rocket ignition to wind turbine interfaces with our kits With regards to usage see the product details on the website ad Perigee Power Solutions Solar Power Kit User Manual Kit Duration Formula Battery duration formula based on total Amp hour and the Amp draw rate of a device you are
10. f ew Perigee Powel psoluti SOLAR POWERED GENERATORS ALTERNATIVE POWER FOR THE HOME ROAD amp FIELD www perigeepower com 443 375 3765 User Manual Model 007 Perigee Power Solutions Solar Power Kit User Manual Congratulations on your purchase of an alternative power charger kit This document is designed to be as easy to follow as it is easy to use our kit for your electrical needs There may be subtle variations between the product and the documentation For example we may change the placement of a switch on the dashboard or rename a given label The functionality will always be the same and the steps provided will persist across any version changes we may make to the interface Refer back to this manual for advice on caring for your kit battery maintenance and general usage Using your Kit Main Power Switch On activates the 12V S pP 1 status LED and powers the 12VDC port Activating Main amp 12 Volt Power e Insert Buss fuse amp turn cap to fit e Switch Main Power to ON e Battery status LED illuminates e Uncap amp use 12VDC socket Notes 1 Ifthe status bar indicates low see the Steps 3 amp 4 2 The 201 modular battery pack may be connected to the 007 via the multi port using our Medium AUX battery MPI cable each sold separately Image shows the 007 with panel connected amp charging kit while simultaneously powering an MP3 player via the 12V port Perige
11. n parallel very useful for our wall mount units connect an auxiliary battery use the port with a voltmeter to observe precise voltage levels or connect to a compatible wind turbine This text will cover connecting an AUX battery AUX Battery amp MPI Gator Cable e Clamp the BLACK clip to NEG terminal e Clamp the RED clip to POS terminal e Insert the keyed power pole connector into the multiport as shown right image e Switch kit main power ON amp connect solar panel to charge chained batteries e When charged to desired level disconnect MPI from multiport Unclamp cable from AUX batter Image shows 44Ah AUX battery amp MPI y cable connected to a 201 kit multiport with a 45W panel also connected to the Solar In panel not in frame Notes 1 Important Do not reverse cross connect the gator cable Doing so will pop the inline fuse If this occurs disconnect the cable amp open the blister on the positive line Replace with a STD ATC 7 5A fuse available at any automotive store 2 Do not connect a dead AUX battery to the multiport Anytime another battery is put in line with the kit both batteries will normalize I E the kit batteries are at 12 8V and the AUX battery is at 11 9V putting them in line will draw down the kit battery to 11 9V If the AUX battery is dead lt 10V you may damage your kits battery We recommend checking your batteries voltage with a voltmeter before putting in line 3 The status bar
12. ng Battery Condition e With Main Power to ON e Observe the LED Status Bar O Low 1 3 bars 10 0V 10 5V Batteries must be charged o Normal 4 7 bars 10 6V 12 5V normal operating range O Max 8 10 bars 12 6V 14 5V max battery capacity Solar In LED shows quality of charge brighter the LED the higher the charge rate The black red connector on the panel to kit cable is called an Anderson connector Step 4 Charging e Main Power Switch On e Connect the panel to kit cable Anderson side to the Solar In port o All Perigee kits use keyed connectors so that cross connections cannot be mistakenly made o The Multi port may be used to daisy chain kits or additional battery packs to your kit It may also be used with a voltmeter to obtain the precise voltage level of your battery e Solar LED illuminates Red brightness indicates charge quality Notes 1 Always turn the power switch on when applying a charge from any source See the maintenance section for details 2 When not using your kit switch off the main power This will increase the lifespan of the battery and prevent potential cell damage from over drain You may remove the fuse to facilitate a hard disconnect if so desired Perigee Power Solutions Solar Power Kit User Manual Multiport Interfacing The multiport is capable of supporting many additional functions for all Perigee Products You may link multiple kits together i
13. on the kit reports voltage of all batteries Kit battery AUX as one battery Image shows AUX battery MPI cable and the blister that houses the 7 5A STD ATC fuse Perigee Power Solutions Solar Power Kit User Manual Maintenance amp Advisories Perigee Power Solutions products are designed to be rugged and dependable There are no serviceable parts that require maintenance aside from what we consider to be basic care Those conditions are as follows 1 Always turn the kits power switch to ON when charging If this switch is left off when a charge is applied from any source the batteries will not charge and the kit may become damaged if this state is allowed to persist A short period in this state is ok simply switch the kit power switch to on Do not allow batteries to fall below 10 volts Periodically charge your kit we recommend once every 8 weeks The power status bar is an accurate representation of the battery charge condition It 1s not necessary to keep your kit at Full Max capacity all the time 12 13 volts are sufficient i e any bar in the normal range on the power meter a Avoid running the kit for an extended period of time with the indicator in the Low position This does not immediately adversely affect the kit but it will eventually reduce the number of cycles that the battery pack may be recharged If the kits battery state is allowed to drain below two bars the warranty may be voided
14. x 10min 600seconds Imin 0 65A 2 600 3600 33 0 65 3000 3600 0 54A Iavg 0 87A Now we can take the duration formula and derive the run time estimate using the average amp hour value plus the inverter consumption lavg 87 21 Total Amp Draw Avg 1 08 x 11 9Ah 4Ah 85 11 9 y 11 0 J1 9 1 08 11 01 xy 9 36 11 01 85 9 36 z 3 74 hours to SDL 9 36 40 3 74 Perigee Power Solutions Solar Power Kit User Manual Battery Recharge Formula Derive the time it takes to recharge a battery from safe discharge level to a normalized state Evaluate the following L Notes Panel Wattage Panel Voltage Rating Amps a 45W panel 17 3V rating 2 6A b 2 6 panel amp rating Battery Amp hr Amp Time 10 a 40 2 60 10 battery variable 16 92 hours b 16 9 gross avg time Calculate for 60 Safe Discharge Level a 16 9 40 6 76 hours b 6 7 hours is the avg time to recharge from SDL in ideal charging conditions Panel ratings may vary You may substitute the 17 3V rating for 15V to normalize your results 17 3V is the rating for the 45W panels we sell Increasing the panel wattage improves recharge time Most inverter manufacturers provide inverter efficiency at 1 3 and full load You may substitute the 85 avg we use for this step c with the MFG rating We provide this data on a kit basis on the specification page when it is available to us
Download Pdf Manuals
Related Search
Related Contents
Shark NV650 Owner's Guide Samsung UN32F5000 User's Manual Philips AE1500 DV 480 User Manual Hockey Canada Registry User Manual [Complete] Zanussi ZOB550WL User's Manual Summit Series V30A(S) T&Cs - Symbio DRIcore CDGNUS750024024 Instructions / Assembly Copyright © All rights reserved.