SenseLife Cam Indoor Air quality Monitor User manual

image

Contents

1. CANCEL 6 Select the folder that you want to save the logging data 5 Click CONNECT button 1 Click SETTING EXIT CONNECT ga e e i ial eine ad ree T3 ETTE Normal RUA Good Ny Poor i ot CO2 al ppm 6 CO2 concentration being displayed on CAM can be monitored If the CO2 level in ppm does not respond it is either because the wrong COM port number was selected in Settings or the USB driver was not properly installed Try selecting each of the different COM ports under settings If none of them work you should unplug the CAM uninstall the USB drivers and repeat Part 1 again 7 To enable data logging click Setting then check Enable data logging and select a path to save the log file It will be in an ASCII text format LOG CSV suitable for easily importing into a database or spreadsheet NOTE The LOG file will not be created until you set the Year Month Date on the CAM and give a valid date range under terms under Settings 8 Click Exit when you want to finish the program Click EXIT CO2 Monitoring System CONNECT f YEAR a7 MONTH i DATE tam N wt ult PM DAY SUN MON TUE WED THU FRI SAT Normal Part 3 Settings 1 Set the Time 1 Pressing Mode at least 2 seconds Year section 2 Set Year by Up Down flickers 3 Pressing Mode once Month ton tickers Get SenselLife 5 Pr
2. ED PRODUCT Doe ttSe OF WHICH I5 SUBJECT TO THIS END USER LICENSE AGREEME AOTCATING YOUR AGREEMENT CONSTITUTES YOUR AND IE APPLICABLE YOUR COMPANY S ASSENT TO AND ACCEPTANCE DEPATS END USER LICENSE AGREEMENT THE LICENSE OR AGREEMERF IF VOU CO NOT AGREE WITH ALL OF THE TERMS YOU MLGFAOT USE THIS PRODUCT WRITTEN APPROVAL IS NOT A Te TT THI LJALI IAI ITL AMA Pee OT OOO L Ae eT a4 I do not accept the terms of the license agreement InstallShield Silicon Laboratories CP210x YCP Drivers for Windows 2000 lt P x Choose Destination Location Select folder where setup will install files Setup will install Silicon Laboratories CP210 YCF Drivers for Windows 2000 P 2003 Server Vista in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder Destination Folder c 4SiLabs MCL InstallShield Cancel Silicon Laboratories CP210s CP Drivers for Windows 2000 P EW Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation IF You want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield Install Cancel Click Next Click Install Silicon Laboratories CP210x CP Drivers for Windows 2000 P 70 InstallShield Wizard Complete Click Launch Laboratories CP210 YCF Dr
3. SenseLife Cam Indoor Air quality Monitor User manual SECTIONS Part 1 USB driver installation Part 2 Program installation Part 3 Set time and date DO NOT PLUG THE CAM INTO YOUR PC BEFORE INSTALLING THE USB DRIVERS OR IT WILL NOT WORK PROPERLY IF YOU HAVE ALREADY PLUGGED THE CAM IN YOU MUST UNPLUG IT REMOVE ANY UNKNOWN DEVICE DRIVERS REBOOT AND FOLLOW THESE INSTRUCTIONS This manual is subject to change without prior notice to increase user s convenience or to add advanced functions Part 1 USB driver installation 1 Go to www co2meter com products cam co2 meter powered by auto home or usb 2 Save the file USB Drivers ZIP to your desktop 3 Unzip the file and run the program CP210_ Win2K_XP_S2K3 exe Follow the on screen instructions Silicon Laboratories CP 710s CP Drivers for Windows 7000 xXP Eg Welcome to the InstallShield Wizard for Silicon Laboratories CP210x CP Drivers for Windows 2000 4P 2003 Server Vista The InstallShield Wizard will copy Silicon Laboratories CP2108 YCF Drivers for Windows 2000 P 2003 Server vista onto your computer To continue click Next Click Next Cancel RY License Agreement Please read the following license agreement carefully 1 Click END USER LICENSE AGREEMENT IMPORTANT READ CAREFULLY BEFORE AGREEING TO TERMS 2 Click Next THIS PRODUCT CONTAINS CERTAIN COMPUTER PROGRAMS AND OLHE HIRD PARTY PROPRIETARY MATERIAL LICENS
4. essing Mode once nn Sat Jon 26 2 2 AM04 29 Day section flickers Set Month by UP Down Day by UP Down sy m 1420 CaM 4 Pressing Mode once Date section flickers Set Date by UP Down 6 Pressing Mode once 7 AM PM section flickers Select AM PM by Up Down 8 Pressing Mode once l 10 Pressing Mode more Hour section flickers Set than 2 seconds you can finish Hour by UP Down time setting 9 Pressing Mode once 1420 CaM Minute section flickers Set Minute by UP Down While time setting mode you can finish setting by pressing Mode more than 2 seconds 1 Pressing Down more than 2 seconds backlight will be Off In the light if Off by pressing Down more than 2 2 Backlight On Off seconds backlight will be on SenselLife We stl iz A 1420 CEiMe
5. ivers for Window Server vista to your hard drive The diveristaller listed below Click Finish to complete the Silicon Laboratories CP210 WEP iria ii Drivers for Windows 200044P 2003 Serverista setup Click Finish Cancel 4 Connect the CAM to your computer by USB cable You will see a pop up Window similar to the one below window can be different depending on your operating system Start new hardware search wizard This wizard helps you install the following software CP2102 USB to UART Bridge Controller 1 Click 2 Click Next C If you have CD floppy disk containing the softw NY please insert s Select work please ation recommended Instaffation from specified list location S lt cnt BE PATIENT It may take a few minutes until the wizard finishes searching If the Wizard is unable to find the driver hit the lt back button and try again Most installations fail because the USB driver is improperly installed Until you read CO210x USB Composite Device is installed do not continue New hardware search wizard complete Wizard completed the installation of software for the following hardware ao CP210x USB Composite Device To finish Wizard click Finish lt Back B Finish Cancel Click Finish 5 To test for proper installation Click Start gt Control panel gt System on your computer epson Ha
6. man interface devices 4 DVD CD Rom drive R 8 If you can see USB to UART COMXX the driver is successfully installed If you cannot see it go to the Control panel again and execute Add new hardware function 9 The COMXX port will vary according to each PC s USB Port Write down this number as you will need it when you install the CO2_monitor exe program 6 Part 2 Program installation 1 Save the Program file Zip named CP210_run zip to your desktop Create a new folder and unzip all the files into the new folder 2 Double click CO2_Monitor exe in the folder to run the program CO2 Monitoring System CONNECT l 1 Click SETTING AN U EA A DAY SUN MON TUE WED THU FRI SAT a m Normal UUL 9 Sy 4 Good Em _ mal Poor EE CO FLL ppm 3 Select the COM port to the setting you wrote down previously Do not check Logging Enable yet 4 Click OK 2 Click when you want 31Loaaina Interval CO2 data logging 1 Select USB Port Please refer to COM Contig eani LPT section at USB Compork Setting SEC Port COM13 Enable Terms for Logging Bound Rate 9600 Data Bits ife Terms Input 2008 01 01 ata Bits ki StopBits 1 Spe Parity hones 4 Terms for data loggin eee Gutput Direchary Flow Control ione start I d dota 7 Click OK 5 gt CO Monitor 5 Terms for data logging finish JK
7. rdware Advanced sore ery Automatic update Remote System Microsoft Windows XP Professional Version 2002 Service Pack 2 User info John Kim Hana Engineering Co Ltd 5663 640 5499621 23601 Computer Intel R Pentium R M processor I500MHz 1 50GHz 512MB RAM 6 Click Hardware gt Device Manager File F Action A View V Help H gt 0 amp ml Network adaptor Disk drive Display adaptor Mouse amp other pointing devices Monitor Modem Battery Multi purpose serial bus controller Sound video amp game controller System devices imaging devices Computer Keyboard Port COM amp LPT Processor Human interface devices DVD CD Rom drive IDE ATA ATAP Controller IEEE 1394 Bus Host controller PCMCIA adaptor SCSI amp RAID controller 2 Fl SF Se ow ee OF el Be Ge PaefQCh scl ob oeSPeEraced 7 Click port COM amp LPT File F lt Action A View Help H gt se g Za Disk drive Display adaptor FI le Gad mS Par aw Mouse amp other pointing devices Monitor Modem Battery Multi purpose serial bus controller sound video amp game controller system devices imaging devices Storage volume Computer Keyboard Port COM amp LPT l F Communication port COM1 F CP210x USB to UART Bridge Controller COM13 F ECP printer port LPT 1 USE Serial Port COM 3 1 w Ha Hu