MVE CRYO-CART - Chart Industries

image

Contents

1. the slotted holes in the ends of the Vapor Platform to hold on to while sliding into the CRYO CART After the Vapor Platform is installed insert a Conduction Sheet between the Vapor Platform and the CRYO CART one on each side See Figure 1 Figure 1 Vapor Platform and Conduction Sheet Document W3170 Man Rev 3 Page 5 of 9 Attach the Digital Thermometer to the mounting bracket on the shelf end of the cart Open the jaws of the Mounting Bracket by pressing the button on the right hand side See Figure 2a Thermometer and bracket supplied on model PN 14448703 only After inserting the Thermometer press the bracket sides towards the Thermometer until it is firmly in place The Ball and Socket connection located on the Mounting Bracket allows for a full range of positions Loosen this joint and rotate the Thermometer until the desired position is obtained HAND TIGHTEN the nuts to maintain the position Periodically check this to unsure that it is not loosened during use See Figure 2b Figure 2a Mounting Bracket supplied with model PN 14448703 only Opening Mechanism Figure 2b Mounted Thermometer and Adjustment Socket Model PN 14448703 only Document W3170 Man Rev 3 Page 6 of 9 Install the type T thermocouple to the thermometer The thermocouple is installed in the plug on top of the thermometer Match the and signs on the thermocouple with the and signs on the thermometer See Figure 2c Model PN 144
2. 1 888 932 2473 Europe Middle East Chart Biomedical Ltd Unit 2 Maxdata Centre Downmill Rd Bracknell Berks RG12 105 United Kingdom PH 44 0 1344 403100 FX 44 0 1344 429224 Asia Australia Pacific Rim Chart Australia Pty Ltd ABN 21 075 909 410 sydney Business amp Technology Centre Unit 43 2 Railway Parade Lidcombe NSW 2141 Australia PH 612 974 94 333 FX 612 974 94 666 Document W3170 Man Rev 3 Page 9 of 9
3. 48703 only en N Figure 2c Installation of thermocouple into thermometer match Thread the end of the thermocouple through the outside end sensor tube and into the freezer The end of the thermocouple may be placed at any desired height inside the freezer but should be placed at a height corresponding to the height of sample storage to accurately monitor the temperate of the storage space occupied by the samples NOTE The digital thermometer included with the CRYO CART is produced by OMEGA Engineering Inc any questions dealing with the operation of the thermometer should be directed to them Refer to the Omega Documentation in the documentation packet for contact information WARNING BEFORE CONNECTING LIQUID NITROGEN SUPPLY INSURE YOU ARE FAMILIAR WITH THE SAFETY PRECAUTIONS NECESSARY WHEN WORKING WITH CRYOGENIC LIQUIDS Connect the transfer hose of a liquid nitrogen supply to the LN2 fill connection on the CRYO CART See Figure 3 Once the supply is connected turn the fill valve open At least one of the lids should be removed during the initial fill of a warm room Document W3170 Man Rev 3 Page 7 of 9 temperature cart Fill the container to the top of the vapor platform Once the desired liquid level is reached the valve should be returned to the off position The off position for the valve handle is perpendicular 90 degrees to the flow path through the valve The on position for the valve handle is p
4. USER MANUAL MVE CRYO CART Model FNLMVECRYOCART BioMedical MVE CHART BIOMEDICAL DIVISION 2200 Airport Industrial Drive Ste 500 Ball Ground GA 30107 Document W3170 Man Rev 3 Page 1 of 9 CRYO CART Assembly Model FNLMVECRYOCART PN 14448703 shown above formerly PN W3170 CRYO CART Assembly Model FNLMVECRYOCART PN W3170LT is configured without plumbing and thermometer equipment Document W3170 Man Rev 3 Page 2 of 9 TABLE OF CONTENTS TABLE OF CONTEN erent een re ern ee ee eee 3 AA 4 bere 4 COMPONEN S 4 CAINE islet CHEN CL INIT OG Cs tice te 4 SeLUP MSMUCHON Se 5 Normal Operating Procedures 8 oue omen ae ne Cee E SETAE eT ener Cm eE Te eR eE Ten nee eRe Cn E 9 Document W3170 Man Rev 3 Page 3 of 9 Receiving Inspection When your new CRYO CART arrives unpack and inspect your CRYO CART 1 Visually inspect the packaging 2 Take the cart out of the packaging 3 Look for hidden damage and inventory the shipment Report Damage In the rare instance that you find damage report it immediately to the carrier Report any missing parts to Chart Inc or your Chart distributor Components Packet contents a User Manual b Limited Warranty Statement Thank You Warranty Ac
5. arallel to the flow path through the valve FOR LIQUID NITROGEN USE ONLY Figure 3 End view of CRYO CART model PN 14448703 shown below if 38 gt lt Fill Valve Handle Valve is in the OPEN position LN2 Fill Connection Normal Operating Procedures LIDS Insure that both lids are kept on the CRYO CART when you are not using it Lids should only be removed when working with samples or when removing or adding samples to the Cart Keeping the lids on the Cart will ensure coldest possible storage space and maximize liquid hold time At least one of the lids should be removed when filling a warm room temperature Cart Document W3170 Man Rev 3 Page 8 of 9 WARNING BOTH LIDS ARE TO BE IN PLACE ANY TIME WHEN THE CRYO CART IS BEING MOVED WITH LIQUID NITROGEN IN IT FAILURE TO HAVE THE LIDS PROPERLY IN PLACE MAY RESULT IN LIQUID NITROGEN SPLASHING OUT OF THE CART Liquid Level The CRYO CART is designed to have a maximum liquid level that is equal to the top of the working surface of the vapor platform This liquid level should be refilled when the thermometer indicates that the current temperature in the cart is approaching the maximum warmest temperature you desire Questions Parts For questions or replacement parts please contact USA Chart Biomedical 2200 Airport Industrial Drive Ste 500 Ball Ground GA 30107 PH 1 800 482 2473 FX
6. tivation Card d Liquid Nitrogen Container and Handling Instruction Guide 2 Thermometer box for model PN 14448703 only Box Contents a Omega HH507R Digital Thermometer w 2 type K Thermocouples b Type T Thermocouple CD of software for Thermometer Users Guide for HH507R Digital Thermometer 5232 Interface Cable Certificate of Calibration for the Omega Digital Thermometer a 9 volt Battery 3 Transfer hose for model PN 14448703 only Vapor Platform 5 Conduction Sheet s Handling Liquid Nitrogen Take Precautions when you use liquid nitrogen Treat liquid nitrogen the same way you would treat boiling water Direct contact with liquid nitrogen may cause burns and freeze your skin Good handling of cryogenic samples dictates that you should always wear gloves and eye protection Document W3170 Man Rev 3 Page 4 of 9 More over nitrogen can displace air in unventilated rooms so always use a ventilated room and keep the lid on the CRYO CART whenever possible Setup Instructions After having completed the initial inspection of your CRYO CART you may begin the set up process lf these items not already installed remove Vapor Platform and Conduction Sheets from the under side of the CRYO CART Install the Vapor Platform piping end first using an angle that allows clearance of the Sensor Tube After the Vapor Platform is lower than this tube it can be inserted the rest of the way in a horizontal position Use

Download Pdf Manuals

image

Related Search

Related Contents

Trust Multimedia Keyboard BE  TE 40 / TE 40-AVR  Old Town Canoe Co. 164 Boat User Manual  User manual - Ntn  新発売に関するお知らせ  mortier modifié aux polymères, qualité supérieure, résistant au  70632 Emulator Terminal Interface  MÓDULO DE PESSOAL - Tribunal de Contas do Estado de  Hampton Bay 16033KIT1-BK Instructions / Assembly  取扱説明書 - ニチリョー  