Home
        GB - UL.com
         Contents
1.      Note   For tropical climates  both the open  circuit voltage values  9 1 1 1a  and the  touch current values  9 1 1 1b  are to be  halved        9 1 1 2    Required to use child test finger to repeat the  test to determine the accessibility of  component     Note     For the child test finger  refer to GB T  16842  test probes 18 and 19     No requirement to use accessibility probes  representing a child   s finger              10       Add requirement  The Insulation resistance  between CATV antenna coaxial sockets and  protective earth of apparatus shall comply  with BASIC INSULATION  If it is possible  that CLASS II apparatus with CATV antenna       No relevant requirement        UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission           coaxial sockets connect with protective earth  of another CLASS   apparatus by other  terminals  the insulation resistance between  them shall comply with BASIC INSULATION  as well     Added Note     If the antenna cable is electrically isolated  from the protective earth before connection  to the apparatus  there are no requirements  of Insulation resistance  but the requirements  of 5 4 11  are applied        10 2    For apparatus intended to be used in tropical  climates  humidity conditioning  temperature  40  C 2  C  relative humidity 93  3    conditioning time 120h     For apparatus intended to be used in other  than tropical climates  humidity conditioning   relative 
2.     Cl  11 Fault conditions  for apparatus intended to be used in tropical climates    by inspection of data or by testing if in doubt        Cl  12 1 3 Impact test  if applicable        Cl  12 1 4 Drop test  for portable apparatus whose weight not more than 7kg        Cl  12 1 5 Stress relief test  for apparatus with thermoplastic enclosure        Cl  12 5 Antenna coaxial sockets mounted on the apparatus          Cl  12 6 Telescoping or rod antennas       UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission           Cl  13 Clearance and creepage distances  only for apparatus applicable to  altitude up to 2000m        Cl  14 10 Batteries  including batteries and electronic protective circuit   if  applicable        Cl  19 Stability and mechanical hazards  if applicable        Cl  20 1 4 Components and parts not covered by 20 1 1  20 1 2 and 20 1 3  if  applicable        Product supplied by  an external power  supply such as power  adaptor or charger   etc        Cl  5 Markings and Instructions  Note  when Cl 7 1  Cl 11 and Cl 19 are not  applicable  no sample is required   only provide marking and instruction for  inspection  including the specification of power adaptor or charger   when part  of clauses are applicable  separate component samples are required        Cl  7 1 and 11 Heating under normal and abnormal conditions  for apparatus  intended to be used in tropical climates   by inspection of data or by testing 
3.  an  altitude exceeding 5 000 m are multiplied by  a factor from Table A 2 of GB T 16935 1        14 3     14 3 2    The line choke and winding shall comply with  the applicable requirements of GB8898 201 1  or with GB 19212 1 and its related part   switching mode power supply transformers  shall comply with GB8898 2011 or GB  19212 1 together with GB 19212 18     No alternative requirement to comply with GB  19212 1 together with the related part        14 5 3    PTC   s shall comply with the requirements of  GB 14536 1  clauses 15  17  J 15 and J 17     PTC S shall comply with the requirement of GB  7153       14 10 4     14 10 5    Add Stress relief test for SPECIAL BATTERY  in  which containment of the electrolyte is  dependent upon thermoplastic materials     Add Drop test for USER serviceable SPECIAL  BATTERY     No relevant requirement        14 12    Add test requirement to Surge suppression  varistors used in order to prevent MAINS  overvoltages coming into the apparatus  test  according to GB T 10194     No relevant requirement        18 1    Regarding intrinsically protected picture  tubes  test per GB 27701  IDT IEC 61965    test method is different from GB 8898 2001     Regarding intrinsically protected picture tubes   test per GB 8898 clause 18 2        20    19    Apparatus having a mass of 7 kg or more  shall comply with stability test  Test at 10  to  the horizontal and Vertical force test     Apparatus having a mass of more than 18 kg  shall comply with stab
4. Guidance for u    rading to GB8898 2011    IEC 60065 Ed 7 1  2005    Note  This guidance document is a translation of official Chinese document which is issued by CQC China Quality  Certification Center  on 2012 04 10  Please refer to the source document where any questions or ambiguities are found in    this translation     Source document link     http   www cqc com cn chinese gkwj rzbzxx bzhbxx webinfo 20 12 04 1 333591 184988358 htm          Changes in GB 8898 2011       Seq    Clause    Changes between New and Old       Requirement in GB8898 2011  New     Requirement in GB8898 2001  Old        Add the warning statement or symbol to  indicate product installation use only  applicable to altitudes up to 2000m        Add the warning statement or symbol to  indicate product installation use only  applicable to non tropical areas     No relevant requirement        2 5 1 i     Clarify that the measured current or power  consumption at RATED SUPPLY VOLTAGE  shall not exceed the marked value by more  than 10       Not clear if the measurement must be  conducted at rated supply voltage              Add related warning or instruction  requirements     d  A warning that an apparatus with CLASS    construction shall be connected to a MAINS  socket outlet with a protective earthing  connection        e  Instructions to ensure correct and safe  installation and interconnection of the  apparatus in multimedia systems           f  If the apparatus is not tested to the stability  require
5. PTC   s shall comply with the requirement of GB 14536 1 clause 15  17  J 15   J 17  in old Standard is GB 7153   see Cl  14 5 3      c  New requirement for VDR   s  see Cl  14 12    d  New requirement for batteries  see Cl  14 10   4 samples of battery is required     e  New requirement for intrinsically protected picture tubes  test method shall comply with GB 27701 IDT  IEC 61965   see CI 18 1      f  Add test requirement for apparatus intended for wall or ceiling mounting  See Cl 19  the associated  mounting bracket provided by manufacturer shall be required     g  If anisolating type antenna coaxial cable connector is used  2 samples of connector are required   h  Add the test requirement for insulated winding wire  see CIl 8 17  8 18  8 22   5 set of sample is required     Note  Components previously certified to GB8898 2001 shall apply for standard upgrade at the same time     UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission     
6. ed as the disconnect device  the  disconnect device shall remain readily  operable    b  where an all pole MAINS SWITCH is used  as the disconnect device  the location on the  apparatus and the function of the switch  shall be described  and the switch shall  remain readily operable        No requirements       UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission           7  Table 3    The values of the temperature rises are  based on a maximum ambient temperature  of 35 for moderate climates  For tropical  climates  permissible temperature rises of  10K less than those specified in this Table  are required     The values of the temperature rises are based  on a maximum ambient temperature of 35     for moderate climates       8 17   8 18     8 22    Add the test requirement for Insulated  winding wire for use without interleaved  insulation  per Annex H      Add the Endurance test requirement for  wound components with insulated winding  wires without additional interleaved  insulation     Add the test specifications of non separable  thin sheet material     No relevant requirement        9 1 1 1     For apparatus intended to be used in tropical  climates  the open circuit voltage and touch  current limit values given in normal and fault  condition shall be halved  For apparatus  intended to be used in other than tropical  climates  the open circuit voltage and touch  current limits are same to the one in old  version
7. humidity  9343     temperature   between 20  C  30  C  t2    C without  condensation  conditioning time 48h     Humidity conditioning  Temperature 30  C   2   0   relative humidity 93   3   2   conditioning  time 2 days        12 1 3    Add steel ball impact test to the non   ventilated solid areas of the enclosure that  protect HAZARDOUS LIVE parts        12 1 4    Add drop test for portable apparatus whose  mass is not more than 7kg        12 1 5    Add stress relief test for thermoplastic  enclosure     No relevant requirement        12 5    Add mechanical stress tests for antenna  coaxial sockets incorporating parts or  components which electrically isolate  HAZARDOUS LIVE parts from  ACCESSIBLE parts or protective earth from  other TERMINALS     No requirement to Antenna coaxial sockets  which consist of component to isolate from  protective earthing circuit              12 6       Add construction requirement for  Telescoping or rod antennas        No relevant requirement        UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission           13     Annex J    The determination of clearance and  creepage distance based upon working  voltage is different from the approach in GB  8898 2001  For apparatus intended to be  operated at an altitude exceeding 2 000 m  but not more than 5 000 m  the minimum  clearance value is multiplied by a factor of  1 48  Minimum clearance values for  apparatus intended to be operated at
8. if in  doubt        Cl  10 Insulation requirements  for the insulation of antenna terminal     Cl  12 5 Antenna coaxial sockets mounted on the apparatus  for isolation  between CATV antenna coaxial sockets and protective earth   if separate  isolator used  2 samples of isolator are required        Cl  14 10 Batteries  including batteries and electronic protective circuit   if  applicable  4 samples of battery are required           Cl  19 Stability and mechanical hazards  if applicable        Note  Above differences apply generally to audio video apparatus  For special products  if applicable  clauses    indicated in above standard difference list should be considered     3  Critical Component list     a  For devices used above 2000m altitude  clearance and creepage distance requirements have significant  differences compared with GB8898 2001 and equivalent IEC standard  CB transferred products involved    the clearance limit is 1 48 times of previous limit based on 5000 m altitude  thus  components bridging  primary and secondary circuit  such as optical isolators  transformers  bridging capacitors  etc   shall  comply with this new requirement   Translator s note  Minimum clearance values for apparatus intended    to be operated at an altitude exceeding 5 000 m are multiplied by a factor from Table A 2 of GB T    16935 1       UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission        b  New requirement for PTC   s  
9. ility test          21       19 3       Add Horizontal force test  applicable to       Apparatus with a mass of 25 kg or       No relevant requirement        UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission           more  or      Apparatus  excluding loudspeaker  systems  with a height of 1 m or  more  or      Apparatus  excluding loudspeaker  systems  in combination with a  supplied or recommended cart or  stand with a total height of 1 m or                      electronic flash apparatus for photographic  purposes             more   22 19 6 Add test for apparatus intended for wall or No relevant requirement   ceiling mounting  23 20 1 4  Other components    relevant flammability Other components    relevant flammability  is HB7 f   category is FH 3 40mm min or FV 2 according  Annex G 1 4 a  S F ay ae oa to GB T 11020 flammability requirements  FH  ammability requirement  HB 75 test   3 49mm min test on sample with 3 mm  sample shall be cut from the end product thickness   with minimum thickness and tested per GB T  5169 16   24 Annex B   The requirement for Apparatus to be The requirement for Apparatus to be  he TELECOMMUNICA connected to the TELECOMMUNICATION  algae j   a 9 pi NETWORKS is emerged in response to the  is according to GB xxxx   related modified clauses of Standard   IEC 62151  detail requirement with  modification  which is different from GB  8898 2001   25 Annex G 3   Add needle flame test for bar
10. ments of 19 1  19 2 or 19 3 due to  fastening in place  the relevant warning or  instruction shall be marked on or provided  with the apparatus        No relevant requirement        UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission           g  A warning that batteries  battery pack or  assembled batteries  shall not be exposed to  excessive heat such as sunshine  fire or the  like        h  If the apparatus is provided with a CRT  with protective film attached to the screen as  part of the safety implosion protection  system in accordance to GB 27701  the  relevant warning  or wording  shall be given  in the instructions        I  For apparatus incorporating antenna  coaxial sockets without isolation from the  CATV network  the following warning  wording or similar wording shall be given in  the instruction manual        Equipment connected to the protective  earthing of the building installation through  the mains connection or through other  equipment with a protective earthing     and to  a cable distribution system using coaxial  cable  may in some circumstances create a  fire hazard  Connection to a cable  distribution system has therefore to be  provided through a device providing  electrical isolation which can withstand  insulation resistance for basic insulation                 5 4 2       Add disconnect device requirement in the  instruction manual     a  where the MAINS plug or an appliance  coupler is us
11. riers shielding No relevant requirement   components from POTENTIAL IGNITION  SOURCES   26 Annex L Add annex L  Additional requirements for No relevant requirement        Standard upgrading requirements    1     Document submittal     1  Intended altitude specification     UL AND THE UL LOGO ARE TRADEMARKS OF UL LLC    2012  All Rights Reserved  Do Not Reproduce Without Permission        2  Intended climatic condition specification     3  User manual  in Chinese   and shall comply with GB8898 201 1     4  Marking label  and shall comply with GB8898 201 1     5  Warning markings required by GB8898 2011     6  Component certificates to comply with GB8898 2011 or instructions of EUT     Differences in tests  At least one complete sample is required        Product electrical  characteristics    Standard Clauses          Product directly  connected to AC or  DC mains    Cl  5 Markings and Instructions       Cl  5 1i Input current test       Cl  7 1 Heating under normal condition  for apparatus intended to be used in  tropical climates        Cl  9 1 Electric shock hazard under normal operating conditions  Testing on the  outside        Cl  10 Insulation requirements  for coaxial terminals        Cl  10 2 Humidity treatment  for apparatus intended to be used in tropical  climates        Cl  10 3 Insulation resistance and dielectric strength  for apparatus intended to  be used in tropical climates  and for the insulation between CATV antenna  coaxial sockets and protective earth    
    