1. JOHN BUNN Neb u Tyke RR COMPRESSOR NEBULIZER MODEL 0112 064 USER S MANUAL Read this manual before operating the nebulizer Save these instructions for future reference Caution Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device J B0112 064 INS LABRevB06 Contents 3 Safeguards 3 4 UNTASSEMDIY DREPE DENE EES 5 Operating INnStUCHOns ede esti eee ted 6 Cleaning and acd aed EEEO 7 Spare Parts POV Technical Specifications Trouble Shooting Guide Symbols key Class 11 Read the instructions Introduction Congratulations on your purchase of the J ohn Bunn Piston Compressor Nebulizer Thanks for trusting us Graham Field guarantees that this product has been manufactured with high quality materials and fulfills all the standing safety standards both national and international Please read the instructions very carefully before using it and use the machine as described here Important Safeguards 1 Read the instruction manual carefully before usi
2. becomes stuck by medication or other substances Under no circumstances should the compressor be opened There is not any part inside it that could be repaired by non qualified workmanship The compressor does not require either lubrication or maintenance Spare parts provided 1J et nebulizer 1 Pediatric mask 1 PVC tubing 1 Adult mask 1 Mouth piece 1 Instructions Manual 1 Air Filter 3 and Warranty Technical Specifications Method of nebulization 222 Dry piston compressor Operation Voltage imi ised acc pared oad anda 110 120V 60Hz ll Power nini ei ri 1 10 1 2 Jet nebulizer maximum capacity 10 mi Mean Mass Aerodynamic Diameter microns less than 5 microns MegicationOUtet ete end 0 33 ml min or greater Liter TANGO Approximate maximum pressure WGN 3 75 lbs UNI CIMGASIONS 6 7 x 5 5 x 4 Operation Humidity and Temperature 41 to 1042 F 30 to 95 RH Storage Humidity and Temperature 142 to 104 F 10 to 95 RH Atmospheric pressure range for carriage and 5 0 500 1060 mb The specifications are subject to change without previous notice Trouble Shooting Guide If something out of th
3. e normal happens during operation please check and correct the following points 1 Incorrectly connected to 1 Het the plug Although the power source properly connecte device is on it 2 Check that power is on 2 No power does not work 3 The AC Adapter is not connected 3 Check the AC Adapter is properly connected 1 Add medication 1 Not enough medication in jet maximum 10 ml The mist does nebulizer 2 Remove excess not come out 2 Too much medication medication from cup tubing 3 Connect the PVC tubing Aerosol output L Air filter is clogged L Replace for a clean air 2 The jet nebulizer is filter dirty 2 Replace for new one reduced low 5 Year Limited Warranty Graham F ield warrants to the origina in material and workmanship for a warranty does not cover failures resu retail purchaser that this product is free from defects period of 5 years from the date of purchase This ting from misuse abuse alteration of the J ohn Bunn Nebulizer System use of improper components or failure to comply with the operating instructions This warranty does not i All requests for warranty service sh Nebulizer System proof of purchase the nature of your service request G by this limited warranty THIS LIMITED WARRANTY IS IN LIE WRITTEN EXPRESS OR IMP ERCHANTABILITY OR FITNESS THOSE IMPLIED WARRANTIES A nclude the Nebulizer System tubing or accessories ould include the
4. h small pointed object 4 Insert a clean J ohn Bunn filter Extra filters are available 5 Push filter cap with new filter into position Caution Do not use cotton or any other material Do not wash or clean the filter Use only J ohn Bunn filters Do not operate without a filter Cleaning and Maintenance Important Before using the nebulizer for the first time or after each use the accessories must be cleaned as follows clean all the accessories except the tubing with a warm water and mild detergent solution Rinse with warm tap water for 30 seconds to remove detergent Soak all the parts in a mixture of three parts water to one part white vinegar for 30 minutes in a container or use a bacterial germicide disinfectant which can be obtained in drugstores Clean your hands properly and take the accessories out of the disinfectant solution Rinse them with warm tap water and let air dry on clean paper towels Put them into a sealed bag Do not dry the nebulizer parts with a towel because this could contaminate them NOTICE It is recommended to clean all accessories after each use to avoid possible infection risk due to contaminated medication Nebulize only medications prescribed by the physician and follow the physician s indications Do not use balsam or aromatic substances Use a dry cloth to clean the out part of the unit The jet nebulizer and the accessories must NOT be boiled The jet nebulizer has to be replaced if it
5. model number of your J ohn Bunn including date of purchase your phone number and raham Field will either repair or at its option replace ree of charge any parts necessary to correct defects in material or workmanship covered U OF ALLOTHER WARRANTIES WHETHER ORAL LIED THERE ARE NO WARRANTIES OF FOR A PARTICULAR PURPOSE EXCEPT FOR RISING BY OPERATION OF LAW WHICH ARE LIMITED IN DURATION TO THE 1YEAR TERM OF THIS WARRANTY GRAHAM FIELD S LIABILITY WHETHER BASED ON CONTRACT TORT WARRANTY STRICT LIABILITY OR ANY OTHER THEORY SHALL NOT EXCEED THE PRICE OF THE INDIVIDUAL OHN BUNN NEBULIZER SYSTEM WHIC 15 THE BASIS OF THE CLAIM IN NO EVENT SHALL GRAHAM FIELD BE LIABLE FOR ANY LOSS OF PROFITS FACILITIES EQUIPMENT OR OTHER INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES Some states do not allow limitations exclusion or limitation of incidental on how long an implied warranty lasts or allow the consequential or special damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state 10 U S A Corporate Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 http www grahamfield com J B0112 064 INS LABRevB06 NFIL 31026
6. ng the unit and keep it for future consultation 2 This nebulizer must be used only for the specific cause it was created for the aerosol therapy Any other use will be considered unsuitable and thus dangerous The manufacturer can not be considered responsible of the damages caused by unsuitable incorrect or irrational use if the unit has been used in electrical installations not in accordance with the standing safety standards 3 The following precautions are especially important The unit is not protected from liquid penetration The nebulizer must not be touched with wet hands Do not use in extreme weather conditions Do not use the device in presence of inflammable anesthetic mix in contact with the air oxygen or nitrogen protoxide 4 Unplug the unit before cleaning or maintaining it Disconnect the nebulizer when not in use 5 Do not untwist the jet nebulizer when the unit is operating 6 Do leave medication inside the jet nebulizer when not in use 7 Do not pour more than 10 ml in the jet nebulizer 8 9 10 1 12 13 Use the unit on stable surfaces Never use while sleeping or drowsy Do not submerge the nebulizer in water Use the unit intermittently Maximum operating period 30 minutes It must stand unused for 30 minutes between uses The mask and the mouth nozzle are for personal use and they must not be shared in order to avoid any infection or contagion Children should use this u
7. nit only under adult supervision This unit must be repaired only by authorized personal NOTE This unit employs a thermal limiter that will shut off the entire product should the motor overheat Features ON OFF Switch Filter Chamber Air outlet J et nebulizer Pediatric Mouth Piece mask Unit Assembl 2 IMPORTANT than 10 ml N oC 0 000 Operating Instructions CMe gt Take the unit out of the box Press the red button and slide the cover backwards then remove accessories Open the jet nebulizer Fig and pour the medication to nebulize into it Do not pour more than 10 ml Fig B then twist both parts and close again Fig C Connect the tubing to the jet nebulizer and the other end to the nebulizer outlet Fig D Put the mask or the mouth piece to be used into the jet nebulizer Fig E Connect the unit to a suitable power receptacle Turn the unit on pressing the ON OFF switch to start the treatment Turn the unit off and unplug it once the treatment has finished Clean the jet nebulizer and the devices as indicated in Cleaning section 0 Store the jet nebulizer and the devices in the unit s storage compartment Filter change 1 Filter should be changed every 6 months or sooner if the filter turns completely gray in color 2 Remove filter cap by grasping it firmly and pulling out the unit 3 Change the dirty filter of the cap wit