1. When error occurs the error information will be displayed on panel It is convenient to find reason of error and get rid of the error as soon as possible NICE2000 controller can save the last 11 error code and record the last 3 error frequency current bus voltage digit input terminal state and digit output terminal state The relative sketch map is listed below PRG Fan FAS ES FAN 0 000 FO gt F9 gt F9 00 gt F9 13 gt 13 Display in stop Fig 4 5 error information reading 4 3 4 Monitor digit input and output terminal state Refer to F7 11 F7 12 parameter instruction in chapter6 4 4 Operation mode of shortcut menu Quick menu is created with the purpose of making it convenient for user to check and modify the parameter in common use The parameter display mode in quick menu is uF3 02 which means the function parameter F3 02 The effect of changing the parameter in quick menu is the same with that in the common programming status At most 16 parameters can be saved in quick menu If 16 parameters are stored and want to add more it will show FULL if enter the menu it will show NULL which means no parameter is stored in the menu 16 parameters already have been stored in quick menu at the beginning 38 NICE2000 User Manual Operation and Test run of controller F0 01 Driving mode FB 07 Automatic oil cycle time F6 03 fas
2. setting range range 50 00Hz 99 00Hz Set the max output power of system Carrier Pependin Default g on the Min unit 0 1KHz F0 05 frequency model setting range 0 5 16 0kHz The magnitude of carry frequency is highly correlative to motor running The carrier frequency generally is set upward10 KHz to travel without noise It is suggested to reduce the carry frequency within noise allowing range When the carrier frequency is low the output current higher harmonic increases and the consumption as well as elevated temperature of motor will increase When the carrier frequency is high the consumption as well as elevated temperature of motor will decline but the consumption elevated temperature and interference of the system will all increase To regulate the carrier frequency will exert influences on the following performance 65 Instruction of function parameter NICE2000 User Manual Carrier frequency low high Motor noise large small Output current wave form bad good Elevated temperature of motor high low Elevated temperature of system low high Leakage Current small large External Radiation Interference small large feed panel default Min unit unit F0 06 reverse feed Setting range This function code can set the elevator running direction but only when FO 01 0 is valid When function code value is 0 suppose the elevator runs up wh
3. PRG IX ENTER ENTER 0 000 gt FO m FP H FP 00 000000 gt 000000 12300 e lt 12000 le lt 12000 4 10000 be 10000 ja ENTER PRG PRG JENTER 12300 12340 12340 5 12345 E FP 00 Fig 4 9 process of password setting After setting the function password parameter FP 00 is not zero if the user presses PRG the controller will enter into password validate state first and display User can only enter the menu after inputting the user password For factory setting parameters editing the user still need to input the factory password Warning do not change the factory setting parameter if the 40 NICE2000 User Manual Operation and Test run of controller parameter values are wrong the controller will work abnormally even be damaged When the password protection is unlocked user can change the password freely and the last input will be the user password If the user wants to cancel the password protection function enter after inputting the password and setting FP 00 as 0 if FP 00 is not zero the parameter is password protected A1 Operation and Test run of controller NICE2000 User Manual 42 Function Parameter Table Function Parameter Table NICE2000 User Manual Chapter 5 Function parameter Table 5 1 Instruction of function parameters 1 Function parameters are classified int
4. ao If bias is represented by b gain by k actual output by Y standard output by X and then actual output is Y kX b 100 A0O bias coefficient is corresponded to 10V 20mA The standardized output is within 0 10V 20mA corresponding simulate quantity O max 80 NICE2000 User Manual Instruction of function parameter It is generally used to modify simulate output zero float and windage of output breadth It can also be any needed output curve which is user defined For example if simulate output content is running frequency and want to export 8V 16mA when frequency is 0 and export 3V 6mA when frequency is max then we need to set gain to 0 50 and set bias to 80 6 7 F6 Group Elevator basic parameters code range Switch variable F6 00 frequency to work 0 2s 0 1s 0 2 0s frequency This parameter is only used in bypass variable frequency When variable frequency accelerates to stable speed after the time set by F6 00 it will switch to work frequency code range Switch work frequency to 0 2s 0 1s 0 2 0s variable frequency time This function code is only used in the bypass variable frequency control situation with similar function of F6 00 When NICE2000 is at start of energy save run in work frequency and variable frequency switch control process export the switch time of output contactor Generally these two parameters are set about 0 2s code range
5. OFF otherwise there will be danger of electric shock Only the specialist can do the job or it may cause damage to equipment or human injury The earth line should be implemented according to special criterion otherwise there will be danger of electric shock or fire Make sure the input power of controller comply with supplied power otherwise the controller may be damaged Make sure the connected motor match with the application motor otherwise there will be damage the motor and arose controller protection e Do not connect power with the terminal U V W otherwise the controller may be damaged 22 NICE2000 User Manual Installation and Wiring 3 2 3 1 Connecting method operate panel r NICE2000 control system outside multifunctio keyboard interface DI3 function extend digit input terminal card interface analog output DC 0 10V 4 20mA faiait output analog input terminal T A De 0 10 T B 4 20mA ATIC Fig 3 3 controllers applied to NICE E A 4013 NICE E A 4060 Bypass usage applied to full range power Full variable frequency usage applied to 4013 4060 models 23 Installation and Wiring OV f pea ope a ov X neen I lt repair Xl up Y2 o d Y own ooo x3 touch point o Y4 lt itouch poin conglutination 4X4 Y 5 S Loo o safety 3 drive chain a X6 E 7 pre reversion
6. Switch variable frequency to 43 0Hz 0 1Hz 0 50 0Hz frequency This function code is only used in the bypass variable frequency control situation When elevator starts to run in energy save mode deviate work frequency control 81 Instruction of function parameter NICE2000 User Manual When the F2 00 is non zero the system will trace down from the set frequency and will be variable freq driven after the tracing is finished the motor sill run at constant speed this parameter is generally adjusting free When the F2 00 is zero the system will trace at the set freq place The motor will run at constant speed after the tracing finished code range F6 03 Quick 1 running 50 0 01Hz 0 Max frequency frequency F6 04 Quick 2 running 0 01Hz 0 F6 03 frequency frequency F6 03 and F6 05 are valid both in the control of bypass variable frequency and complete variable frequency F6 04 is suitable for complete variable frequency and can satisfy the demand of traditional speed complete variable frequency system Generally speaking parameter of quick 1 frequency is set to work frequency and parameter of quick 2 frequency is another standby option In the complete variable control mode if input terminal function convert speed selection is valid NICE2000 will adopt quick 2 running frequency for quick aim frequency if convert speed selection is invalid NICE2000 will adopt quick 1 frequency for quick aim frequency Q
7. Fault Diagnosis and Countermeasures NICE2000 User Manual Operate Fault 3 panel aes Fault cause Disposal way k description display failure abnormal factory Output side 1 The connections of main i 1 Inspect connection Err 13 phase loop output become loose 2 Obviate motor fault failure 2 Motor is broken 1 The temperature of working i 4 1 Reduce the environmental environment is too high Module temperature Err 14 2 The fan is broken overheated i 2 Clear the wind channel 3 The wind channel is 3 Change the fan blocked Err 15 Reserved Err 16 Reserved 1 Bus voltage is abnormal Contactor i Please contact with agent or Err 17 2 Drive control panel is fault factory abnormal Current r i Diver control panel is Please contact with agent or Err 18 detection abnormal factory fault TOENE 1 Input the right motor 1 Motor parameter setting is parameter wrong f r 2 Detect motor lead wire Motor tuning 2 Parameter tuning is Err 19 3 Detect the rotate encoder fault overtime wiring and make sure the 3 Synchronous rotate pulse number per round is well encoder is abnormal set 1 Asynchronous motor can select push pull output or Rotary 1 Rotary encoder model is open collector encoders Err 20 encoder suited or not synchronous motor can select fault 2 Encoder connection error UVW or SIN COS 2 Obviate connection problem
8. Rated voltage 0 440V 45 Function Parameter Table NICE2000 User Manual F1 03 Rated current 0 00 655 00A 0 01A F1 04 Rated frequenc 0 00 99 00Hz 0 01Hz 50 00Hz rotate F1 05 0 3000rpm 1 rpm F1 06 Stator resistance 0 001 30 0000 F1 07 Rotor resistance 0 001 30 0000 Leakage F1 08 0 01 300 00mH inductance F1 09 Mutual inductance 1 2000 0mMH F1 10 No load current 0 01 300 00A model 0 no tuning F1 11 Tuning selection 1 static tuning 1 2 complete tuning Depend on the F1 12 F1 13 F2 Group Vector control S Frequency tracing F2 00 0 100 response speed Frequency tracing F2 01 constant speed 0 01 10 00s 0 01s 0 60s delay time Switching 0 00 F2 05 0 01Hz 2 00Hz frequency 1 F2 03 Proportional gain 2 0 100 oao 46 NICE2000 User Manual Function Parameter Table Name setngronge of speed loop ae S E Integration time 2 F2 04 0 01 10 00s 0 01s 0 90s of speed loop Switching 05 F2 02 F0 04 0 01Hz 5 00Hz frequency 2 Frequency tracing i 50 130 1 100 current setting Filter coefficient of F2 07 0 00 5 00s 0 01s 0 00s speed loop Upper limit of F2 08 0 0 200 0 0 1 150 0 torque filter 2 F2 2 F3 Group VF function parameter 0 0 automatic F3 00 Torque hoist 1 0 0 1 30 0 Torque hoist F3 01 0 F0 04 0 01Hz 50 00Hz frequenc 0 1 F3 02 Slip compensation 0 0 200 0 0 invalid 1 valid of all process F3 03 AVR select i 1 2 2 only inv
9. Contacts driving capacity Y5 CM1 Relay output 5 Relay AC 250V 3A Cos 0 4 Y6 CM1 Relay output 6 output DC 30V 1A YOMI Relay output7 Note CM1 and CM2 are cut off inside Y8 CM1 Relay output 8 Y9 CM2 Relay output 9 Y10 CM2 Relay output 10 Y11 CM2 Relay output 11 Communic RX i MODBUS Shielded twist pair wire STP is ation RX communication recommoneded terminal 5 Instruction of terminal connection A Analogue input terminal The feeble analogue signal is apt to be influenced from outside interferer so shielded cable is needed commonly and the wiring length should be no more than 20 meters Make sure to keep the shield layer which closed to controller well grounded Refer to Fig 3 5 In the situation of some serious interfere filter or ferrite magnetic core should 28 NICE2000 User Manual Installation and Wiring be added at the side of analogue signal source Refer to Fig 3 6 less than 20m 0 022UF 50V a bls le e oe 4 es a ferrite magnetic loop through or circle 2 3 in the same Fig 3 5 Terminal connection Fig 3 6 Signal disposal connection B Digital input terminal Shielded cable or twisted line are usually used in wiring refer to 3 2 1 external electric components and the wiring length must be as short as possible less than 20 meters If use shielded line please connect shielded layer into terminal PE which is
10. FP 02 FP 02 User setting examine MRE 104 NICE2000 User Manual Instruction of function parameter After having selected FP 02 function operating panel LED only display the parameter which is different from default in order to make it convenient for user to check up the setting and discover problems 105 Instruction of function parameter NICE2000 User Manual 106 Typical application and adjusting of system Typical application and adjusting of system NICE2000 User Manual Chapter 7 Typical application and adjusting of system 7 1 Typical application of bypass variable frequency Escalator bypass variable frequency technique is the combination of variable frequency drive and work frequency drive The predominance of convert frequency drive is when startup and wait state motor will shift smoothly with small current concussion so that when there are few passengers the escalator will running at slow speed It not only can save energy but also can reduce mechanical abrasion The advantage of direct electricity drive is calm speed running process which use the simplest mode to achieve energy feedback without brake resistance So bypass variable frequency is that take advantage of variable frequency drive into the variable speed process If switch the drive motor to work frequency and prepare to enter rated speed running inverter bypass will wait In this process inverter work for a short time so that save the system
11. So capacitance or inrush suppressive equipment is forbidden to been added at output side 3 3 2 Electromagnetic interference and its disposal There are two kinds of electromagnetic interferences 1 The first one is the surrounding electromagnetic noise interference which will bring the controller mis activation Generally speaking this kind of interfere will not cause great influence because this part has been high test when designing the controller It has comparatively strong anti jamming capacity Premises to settle the problems a the controller is well grounded and the earthing resistance can not be more than 5Q b drive power line of the controller should not parallel with control line if permitted try to collocate 30 NICE2000 User Manual Installation and Wiring vertically c at the place with high interfering request shielded cable between controller and motor should be adopted and keep shielded layer well grounded d as to the down lead which suffer the influence of interference it is suggested to use double twist shielded line and keep the shielded layer well grounded There are two kinds of surrounding electromagnetic noise interferences one is controller s radiation the other is produced by the down leads between controller and motor Both will bring electromagnetism or electrostatic induction to the surface of the surrounding equipments Common solutions are listed below 1 Apparatus receivers or sen
12. a DC bus and terminals Please pay attention that the DC bus terminals and still have voltage after power off and the user cannot touch the terminals until the indicator light CHARGE turns off and the voltage is below 36V Do not connect the brake resistance with DC current bus directly otherwise it may cause damage to controller or even fire b Controller output side U V W The output side of controller should connect to 3 phase motor When the motor operating direction is reversed with the actual requirement change any two of the U V W cables to change the operating direction The output of controller cannot connect to capacitors or inrush absorber otherwise it may cause frequent protection of the controller or damage to it Controller output circuit earth line or short circuit is forbidden Controller output cables of U V and W should be in metal pipe with earth line and divided or vertical with control circuit cables If the cables between the motor and the controller are too long electrical resonance may occur due to the distributed capacitance which may result in damage to the motor insulation or leakage current that will make the controller go into protective status Usually the cable length should be less than 100m It is recommended to add AC output reactor when the length is above 100m c Grounding terminal Grounding terminal must be connected to the ground reliably The ground cable sho
13. first level function code second level function code setting third level You can refer to operation flow chart Fig4 2 36 NICE2000 User Manual Operation and Test run of controller Change Change Change arameter grou i arameter ENTER ort ENTER function code ENTER P gt gt r 50 00 FO F0 06 50 00 PRG PRG PRG Data display 1 level menu 2 level menu ENTER 3 level menu Fig 4 2 operation flow chart of 3level menu Note when in 3rd menu system can be backed to 2nd menu by pressing PRG or ENTER The difference between them it goes back to 2th menu with parameter saved when pressing ENTER then jump to next function code automatically while it back to the 2 menu with the parameter unsaved and it will stay in the current function code Example change F0 04 from 50 00Hz to 15 00Hz boldfaced words means flash bit Display in stop PRG IENTER N ENTER 0 000 pue FO F0 00 gt F004 50 00 L a 50 00 V _ 2 PRG ro LERG poos ENTER 15 00 be 10 00 Fig 4 3 parameter editing operation process In 3 level menu if the parameter has no flash bit it means the function code cannot be changed and the possible reasons are 1 This function code is un revisable such as the actual examine parameter and running record parameter 2
14. input of stop signal The signal available indicates lift in the stop state as well as NICE2000 22 N O input of normal parallel connection When NICE2000 is used to connect in parallel it needs to identify if the external signal of NICE2000 normal or not Only when both controllers are in normal state can we make parallel connection Options 25 46 They are the N C signal points of the above mentioned options with same functions Safety brake Min unit F4 22 delaying time getraut a99ms ims Setting range 0 65535ms The escalator will output safety brake after this parameter set time when the drive chain broken or over speed and reversion error occur 74 NICE2000 User Manual Instruction of function parameter Frequency tracing error auto default 3 Min unit 1s reposition time Setting range 1 10 F4 23 When the Em02 Em07 errors occur the system will restored and run with low car speed after this parameter set time This parameter is valid only when the bit 5 of F4 27 is 1 Frequency F4 24 tracing time limit Setting range 1 20 default 10s Min unit 1s This parameter is valid only when the BIT 5 of F4 27 escalator auxiliary function selection is 1 ae a oe When the controller key is start up the elevator need some time to switch from high speed to low speed If the running time is over the above time FB 09 F4 2
15. 2 of the ninth 0 65535 error Terminal output F9 32 state of the ninth 0 65535 error F9 33 Fault frequency of 0 00Hz 99 00Hz F9 F9 F9 F9 F9 F9 F9 21 23 24 25 26 27 0 50 eighth error 29 50 57 Function Parameter Table Function Parameter Table NICE2000 User Manual thenintneror Fault current of the F9 34 0 0 99 99A 0 01A ninth error Bus voltage of the F9 35 0 999 9V ninth error Month and day of Reserved the ninth error Time of the ninth Reserved error Information of the tenth error Terminal input state 1 of The 0 65535 1 tenth error Terminal input state 2 of The 0 65535 1 tenth error Terminal output state of The 0 65535 1 tenth error Frequency of the 0 00Hz 99 00Hz 0 01Hz tenth error Current of 0 0 99 99A tenth error Bus voltage of the 0 999 9V tenth error Month and day of Reserved the tenth error Time of the tenth Reserved error Information of the last error Terminal input state 1 of the last 0 65535 error 58 F9 42 F9 47 NICE2000 User Manual Function Parameter Table Terminal input state 2 of the last 0 65535 1 7 error Output state of the F9 50 0 65535 1 last error terminal Frequency of the 0 00Hz 99 00Hz 0 01Hz i last error Current of the last F9 52 0 0 99 99A 0 01A i error Bus voltage of the F9 53 0 999 9V 0 1V last error Month and day of F9 54 Reserved 1 last error FA Group Communication parameters 0 30
16. Chapter 4 Operation and Test run of controller Summarize we will give detailed information in operating keyboard and function code setting of display panel of the NICE2000 in this chapter 4 1 technical terms of NICE2000 controller Main parts operation mode control mode running mode and working state 4 1 1 Operation mode The definition of operation mode it is the modes of receiving running command and speed instruction NICE2000 control system can select only one of the operating modes hereinafter 1 Operating panel control use the key RUN and STOP of the operating panel to control the controller output 2 Command control terminal the running command and running speed are controlled by multi functional input signal of input terminal 4 1 2 Running mode NICE2000 control system can select only one of the control modes hereinafter 1 Self tuning running mode NICE2000 control system provides self learning mode under loaded state and unloaded state For details please refer to parameter F1 11 2 Common running mode running under the control of operating panel 3 Elevator control mode the running speed is controlled according to the logic state of elevator control carry through auto selection 4 1 3 Working state NICE2000 control system have four states in live state stop state program state running state and fault alarm state 1 Stop state Re electrify or stop after running command finished the controller
17. D X 5 y gt lt brake open g o A lt I fire alarm 9 3 Y9 lt up step loss 5 i x10 X lyo ical lt down_step loss OD i x1 fyg _7 automatic Z energy save X12 bypass y3 high_ty14 speed NICE2000 User Manual up running signal relay output down running signal relay output Y signal relay output A signal relay output run signal relay output brake signal relay output assist brake signal relay output oil signal relay output buzzer signal relay output up direction signal relay output down direction signal relay output Fig 3 4 expansion boards applied to NICE E 1 A 4013 NICE E A 4060 The function of expansion input and output terminals can be set neatly and the function in Fig3 4 is factory default 3 2 3 2 Main circuit terminal and its circuit a Instruction of main circuit terminal s function Table 3 3 Terminal Name Instruction R S T S phase powerihpul a hase AC 380V terminal Position and negative Slated DO DUS INpULTON 9 controller above 37KW they are terminals of DC bus for brake unit Taimiras tor break For controller below 30KW P PB include 30KW they are for brake resistor unit 24 NICE2000 User Manual Installation and Wiring Terminal Name Instruction U V W Controller output terminal Connect 3 phase motor PE Terminal for grounding Grounding terminal b Cautions in wiring
18. F4 12 X12 terminal selection F4 13 X13 terminal selection F4 14 X14 terminal selection selection F4 16 DI 2 terminal selection F4 17 DI 3 terminal selection F4 18 DI 4 terminal selection F4 19 DI 5 terminal selection X01 X14 DIi DI5 are switch input terminals and they can select corresponding function codes 00 46 the same function code cannot be used repeatedly Every function has corresponding code The code of every function is as follows 00 No function The controller does not work even if the signal is input Set the unused terminals as none to prevent error work 01 N O input of safety circuit signal It is an important guarantee of lift safety running including a lot of safety switch device Any fault happened to safety circuit will cause to the elevator s direct stop So it is a necessary condition of elevator running 02 N O input of inspect signal 03 N O input of up motion 04 N O input of down motion Insert examine handle into examine interface of upper down machine room and elevator will come to examine state When examine signal is input to the NICE2000 system the system will cancel whole normal running into examine 72 NICE2000 User Manual Instruction of function parameter circs When having examine up signal or examine down signal input to the system elevator is running with examine speed 05 N O input of host motor test speed signal For the sake of elevator safety we need
19. at once if abnormity happens 1 Check mechanical and electric connection 114 NICE2000 User Manual Typical application and adjusting of system Check periphery before electrify in order to ensure human safety a Suitable component type b Well connected safe circuit c Noperson in elevator and safe running condition d Well grounded e Correct periphery connection according to factory drawing f Credible switch g Check resistance between phases of main circuit and judge whether connected to the earth h Confirm that the elevator is in inspection state i make sure that machine is installed correctly and it will not damage to human and equipment 2 Power check It is necessary to check the power before electrify a The voltage between every two phases of user power should within the range of 380V415 and imbalance range of each phase should be no more than 3 b The input voltage of interface terminal between DC and DC is DC 24V Note It will cause devastating result if the input voltage is over the allowed value please check carefully Please confirm positive and negative polarity of DC Don t move the car if the system input power is in phase failure state 3 Grounding check Please check the electricity supply before the system is power on a Find out whether the resistance between grounding terminal and PE is infinite if it is too small check immediately e Between R S T and PE e
20. big issue so pay attention to the notices below 1 Please install the controller vertically to be convenient for heat dispelling upwards Never invert 2 The installation space should be absolutely conforming to Fig 3 1 to make sure the heat dissipation of the machine And do not forget the heat situation of other parts in the cabinet 3 Installation bracket should be incombustible material 4 As to the hermetic places with powder the space should be enough 3 Teardown and installation of panel NICE2000 controller under 15KW adopts plastic shell the teardown and installation information is in Fig 3 2 1 Teardown Find the pothooks under the plate and push towards inside using tools 2 Installation First put the upside meatus at the down cover plate into the apertures at the up cover plate then press forcibly downwards until hearing the sound of chatter Note Don t teardown the main part of the plastic shell please contact our company if repairing needed 19 Installation and Wiring NICE2000 User Manual up cover plate pothook pothook slot Fig 3 2 teardown and installation of cover plate under plastic shell NICE2000 controllers above 18 5KW adopt sheetmetal shell the teardown steps of bottom cover plate under sheetmetal shell are listed below 1 Loose the screw of down cover plate directly using tool 2 Raise the down plate lightly 3 Draw out the down plate backwards lightly
21. cost NICE2000 provides a suit of traditional Y standby control system besides bypass variable frequency control With these two systems it can reduce fault at largest extent NICE 2000 has combined the escalator controller and inverter together providing user a special resolvent It not only can make full use of variable frequency and work frequency but also can eliminate the brake energy save resistance Energy save low equipment cost and compact structure all of these advantages are definitely the future trend of escalator development 7 1 1 connection mode 108 NICE2000 User Manual Typical application and adjusting of system Inspection Up Down Contact conglutination Safety Drive chain Invorsion Brake switch Fire alarm Up rundle missing Down rundle missing Auto energy saving Star delta Run Full convert freq 2nd speed ee Se ae Fig 7 2 expansion board wiring 109 Up run signal Down run signal Star signal Delta signal Run signal Brake signal Auxilary brake signal Oil signal Buzzur signal Up signal Down signal Typical application and adjusting of system NICE2000 User Manual DC DC Safety brake output DI2 Right speed measure 0002H0IN Controller Main circuit DIS Up photo electric switch card NCTC TBB A Fig 7 3 NICE2000 main board wiring including synchronous switch card 7 1 2 Parameter setting Fa
22. in phase F8 14 Switch coefficient of 1 13 down in phase When in bypass convert frequency control due to the sudden brake of voltage happened in the switching from convert frequency to work frequency the elevator may shake with unstable speed F8 13 and F8 14 are aiming to eliminate this phenomenon F8 13 and F8 14 are only valid in bypass convert frequency and cannot work without NICE2000 in phase switch card When F8 13 0 F8 14 0 this function is invalid If parameter is set at the range of 1 13 it denotes the different switch mode of NICE2000 In the debugging process change the parameter in turn if the setting is appropriate it can come to the calmest switch 88 NICE2000 User Manual Instruction of function parameter Change to F6 00 parameter or periphery contactor act time will influence the setting of the F8 13 and F8 14 so the debugging process must conduct as 1 first set F6 00 0 2 debug F8 13 and F8 14 rectifying from large to small until feel the transition smoothly If basically can feel the shake every time minish F4 26 parameter decrease 30 every time until the shake is eliminated 6 10 F9 Group Protection function parameter Overload protect Default Min unit ea Setting range range 0 The system has no over load protection 1 The system has over load protection Refer to F9 01 Overload coefficient range The reference of this function code is over loaded current When system has det
23. is always at the wait state until receiving another running command At this moment indicator light will go out with the contents in LED screen flashing can use key to display different parameter circularly 2 Program state 34 NICE2000 User Manual Operation and Test run of controller Examine and set up the parameters through operating panel of controller 3 Running state The running indicator light is on when the controller is at the state of running with the contents in LED screen un flashing 4 Fault alarm state There comes fault of controller and the fault code is displayed 4 2 Introduction of operation and display panel Operation keyboard with LED display is the standardized configuration of NICE2000 control system Through this keyboard user can modify the function parameter monitor working state of controller and control its running state start or stop As to the appearance and function section please refer to Fig 4 1 Fig 4 1 operating panel 1 Instructions of functional indicate lamp RUN If it is on controller is working It is the light of keyboard operation and long distance operation LOCAL REMOT Light on means the controller is in the state of long distance operation state Indicator light of forward and reversed rotation Light on means FWD REV forward rotation TUNE Tuning Indicator if it is on the controller is in tuning state 2 Digital display a
24. near the side of controller When using active drive filter measure is essential to avoid serial interfere It is recommended to use contact control mode C Digital output terminal When digital output terminals need to drive the relay absorbing diode should be added at both sides of relay loop Otherwise the DC 24V power will be damaged Note Absorbing diode must be setup correctly which means its polarities have to be installed properly Otherwise when the digital output terminal have output it will burn out the DC 24V power immediately 29 Installation and Wiring NICE2000 User Manual RELAY DIODE Fig 3 7 connection sketch of digital output terminal 3 3 The solution for EMC problem 3 3 1 Influence of harmonics 1 The electric power has high frequency harmonics in itself and will produce great influence to the rectify part making the rectify bridge work for a long time so that the excessive heat may cause the work point drifting and harmful to the rectify bridge If the power supply system is not so good in some place it is suggested that add filter or AC input reactor between the electric power and controller or install DC reactor at controller bus to settle the harmonics problem so that protect the controller 2 The controller output side will produce high frequency harmonics if adding capacitance or inrush suppresser which aims to improve power factor will bring loop current shake and lead to equipment damage
25. slow stop cycle 0 half automatic mode Auto function running FB 17 selection 1 full automatic mode FB 18 Y A switch time 0 invalid Safety arrester act FB 19 1 continuous working 1 mode y i 2 short time working 0 10s electromagnet Safety brake act i FB 20 avail for short time 1s 4s keep time work Comparison table FB 21 7 x of input and output FF Group Factory parameters reserved FF 00 Factory password Reseed FP Group User parameters 0 65535 O no FP 00 User password 1 x password 0 null 1 recover factory Parameter update parameter 1 2 clear memory information User setting 0 invalid FP 02 1 inspect 1 avail 61 Function Parameter Table NICE2000 User Manual 62 Instruction of function parameter Instruction of function parameter NICE2000 User Manual Chapter 6 Instruction of function parameter 6 1 FOGroup Basic parameter eal Default 1 Min unit 1 FO 01 note Setting range range 0 1 2 3 It can set the mode of running command and running speed of the system 0 Operating panel control Use the key RUN and STOP to control the machine and the running speed is determined by F0 03 running frequency of panel control This running mode is mainly used for the debugging process of NICE2000 When NICE2000 is in running we have 3 ways to control the elevator 1 Bypass conversion frequency drive When in this mode NI
26. system Ra a range 0 Forbid 1 Permit Select if protection to the input phase loss situation is allowed Only for model above 7 5KW Fa EA range 0 Forbid 1 Permit Select if protection to the output phase loss situation is allowed Function Name Defa Min eerie sanue code ult unit g 9 _F9 13 The firsterror information _ o 1 oso Fo 14 Reversa to tt om2 91 Instruction of function parameter NICE2000 User Manual Function Name Defa Min eon rende code ult unit 9 g Fens The second eror mromaton o oso roae Reversed 01 oa _F9 17 _ The third error information 1 oso F9 17 The third error information 1 0 50 1 E EN 1 pi 1 O l F9 19 The fourth error information a1 0 50 The fifth error information 1 0 1231 1 oso a om3 1 oso a om3 F9 28 Reversa td a h os EE EE o EE _ EE EE EE EE EE EE EREE i EEEN pot e esses oof s ECEAT 0 1v co EE o E EE 2 2 ga oj Joj l oa oa oO oO Fo 19 informati _F9 20 _ F9 21 i _F9 22 F9 24 Reversed _F9 25 The seventh error information _ F9 26 Reversed _F9 28 _F9 29 The ni i jo to oa oO The ninth error information The ninth error terminal input state 1 F9 31 The ninth error terminal input state 2 E The ninth error terminal output state The ninth error fault frequency The ni
27. 0 0 1s 0 0 3000 0s accelerate time 83 Instruction of function parameter NICE2000 User Manual Examine frequency is the aim frequency of examine running At accelerate examining process use F6 10 1 Inching examine accelerate time is the time needed from zero to max frequency 2 If examine aim frequency is less than Max frequency actual accelerate time F6 Sas frequency max a ceo rent 11 pe mode Le ot 1 barra This Function code sets the inspection running mode 1 Y type running 0 Determined a FO AmA es mode Funotion Name Defaut Min unit unit m range code F6 12 pp Wequency Emi oom 0 10 00 switch surplus poga Down trequency 51 0 01Hz 0 10 00Hz switch surplus They are assistant parameters of up down frequency switches If after adjustment of F8 13 and F8 14 the switch effect is not obvious and elevator is running with strong mechanical friction user should increase this parameter group in a slight extent 6 8 F7 Group Assistant function parameter fase oral parameter an F7 00 ec e i FIRA Setting range range 1 16383 F7 00 can control the display of 14 running parameters and each parameter is controlled by a binary code 1 display this parameter 0 don t display this parameter For example if F7 00 is set to 8191 the elevator can monitor 13 parameter states through shift key on operating panel Bit0 running frequency Bit2 DC bus voltage B
28. 000 User Manual Gross A B H Ww D aperture J Controller type weight mm mm m mm mm mm kg NICE E A 4037 NICE E A 4045 235 447 460 285 220 96 5 14 NICE E A 4060 2 6 option units Table 2 4 Name Type Function Remark 3 Adopt RJ45 Outside lead LED MCTC OPR Lead LED display and interface super operate panel A operate keyboard outside i distance use Different MCTC OPL 0 ERPI specifications Extend cable Standardized 8 chip wire 150 provided such as 1 5 meter Smooth transition of Bypass variable frequency Synchronous i convert frequency MCTC TBB A synchronous switch card switch card and work as fig 2 3 instruction frequency If option units listed above needed please illuminate while ordering O MCTC TBB A in phase switch card B Fig 2 3 MCTC TBB A synchronous switch card Specifications A 62mm B 60mm_ Height 25mm Size of crust Length 68mm Width 66mm_ Height 25mm 14 NICE2000 User Manual Product Information 2 7 Daily maintenance of controller 2 7 1 Daily maintenance The components in the controller may become aging due to the influence of ambient temperature humidity dust and vibration which will cause further potential faults and reduce the life of controller Therefore it is necessary to keep daily or periodic maintenance of controller TBroanger Never do maintenance or
29. 0BPS 1 600BPS 2 1200BPS 3 2400BPS 4 4800BPS 5 9600BPS 6 19200BPS 7 38400BPS 0 No checkout data Baud rate setting format lt 8 N 2 gt 1 Even checkout data FA 01 Data format format lt 8 E 1 gt 2 Odd checkout date format lt 8 0 1 gt 0 127 FA 02 Motor address broadcasting address FA 03 Response dela 0 20ms Communication 0 0 s invalid overtime 0 1 60 0s FA 04 59 Function Parameter Table NICE2000 User Manual FB Group A special J JEF Delayed time FB 00 0 0 9 90 985 oimais 0 invalid speed test Error range of speed test 0 99 30 mainframe Handrail speed step lose error 0 99 30 range Rated pulse 0 200 S host motor 0 no detection Pulse interval of 0 0 99 99s 0 1S 0 00s handrail speed 0 no detection Pulse interval of 0 0 99 99s FB 05 0 00s step loss 0 no detection Holding time of 0 999s automatic oil Cycle time 0 9999h automatic oil Holding time of 1 99s activate buzzer Holding time of FB 09 10 3000s quick running Holding time of FB 10 10 3000s slow running Runtime 0 30s reversed entering Assistant brake FB 12 1 9 9S time Brake open FB 13 0 5 9 9S detective time Examine stop FB 14 0 9 9S delayed time 60 NICE2000 User Manual Function Parameter Table Code name setngrange FB 15 Oil mode selection 0 invalid 1 quick stop cycle Energy save mode FB 16 i 2 quick slow cycle selection 3 quick
30. 5 with no passengers it will turn to low es running bell Soy F426 Ai Ai apex value selection _ value selection 1350 bed ead 1200 1600 The relative parameter of in phase switching card of elevator when in high speed running it is a judge condition of the switching The setting amount cannot exceed the actual input of Ai apex or the judge may not be precise so that the switch will overstep the F4 28 time limit then forced to switch If no obvious improvement happens after the debugging experts adjust F8 13 and F8 14 minish the parameter with the amount of 30 every time ee function ea unit Defaut F4 27 Settingrange range 0 65535 75 Instruction of function parameter NICE2000 User Manual Bit 5 Bit 7 are the new added and the default 21 is corresponding to Bit 0 Bit 2 Bit 4 valid BITO 0 The inverted photoelectricity doesn t work which means the elevator will not accelerate in case of passenger entering in reversed direction in decelerating process or low speed climbing 1 The elevator will accelerate to high speed running when there are passengers entering in reversed direction Bit 1 Set as 0 high speed startup after key switch action escalator reach high speed running state Set as 1 low speed startup after key switch action escalator reach low speed running state BIT2 0 Monitor the mainframe both in high speed running and low speed running 1 Monitor the mainframe o
31. B may explode when they are burned and poisonous gas may be generated when the plastic parts are burned Please dispose the controller as industrial rubbish 1 2 13 About adapt motor gt The standardized applicable motor of controller is four pole squirrel cage asynchronous motor Please pay attention to the useable range of the controller rated current when select the applicable motor gt The cooling fan and rotor axis of the un conversion motor is linked in the same axis When the rotor speed slows down the fan cooling effect will be NICE2000 User Manual Safety and Precautions reduced too Therefore customer should add strong exhaust fan or replace the motor into variable frequency motor in the circumstance of motor overheat gt Short circuit inside the cable or motor will result in the controller alarm even exploded the motor Please do the insulating short circuit test at beginning This test is also necessary in the daily maintenance When doing this test the controller and tested part must be cut off completely Safety and Precautions NICE2000 User Manual Product Information Product Information NICE2000 User Manual Chapter 2 Product Information Summarize In this chapter we introduce NICE2000 elevator control system in details including related information of each part daily usage and maintenance type selection instruction of it and so on It will help the clients to use our products safely 2 1 Name de
32. Between U1 V1 W1 and PE e Between motor U21 V21 W21 U22 V22 W22 and PE 115 Typical application and adjusting of system NICE2000 User Manual e Between mainboard 24V and PE e Between terminal of safe circuit inspection circuit and PE b Find out whether the resistance between grounding terminal of all the electric part and power input PE is infinite if it is too small check immediately 7 3 2 Adjustment After checking the periphery take off brake control wire and turn the electricity on Observe whether have output or not in the state of un running even if brake control wire is connected brake can t be open as well then cut off the power and connect brake control wire Prepare run at low speed 1 Check after power on 1 Make sure the input voltage on main board between CN2 24V and COM is within range DC24V 0 5V 2 Make sure the voltage between DC and DC terminal CN1 is 24V 2 Setting function of terminal parameters check Terminal function parameter group F4 and F5 will decide whether the received signal is correspondent with signal sent by system and whether the expected aim is same with real aim 1 Check whether the function of each setting terminal right according to the factory chart and whether input output terminal type is complied with the actual type 2 Check out the corresponding input terminal signal is normal or not through the numeral pipe on off LED and input output setting
33. CE2000 will automatically select variable frequency drive or work frequency drive according to the state of elevator example if there is any passenger When no passenger is on the elevator it will switch from work frequency to variable frequency while having passengers the elevator will accelerate switching to work frequency 2 Complete conversion frequency drive In this mode whether the running speed of the elevator is high or low NICE2000 adopts variable frequency drive constantly NICE2000 automatically control the speed according to the passenger state no passenger variable frequency at energy saving low running while having passengers variable frequency accelerate to high running 3 Y A direct start NICE2000 will use Y A to startup directly instead of variable frequency drive in this mode When over current fault happens Y A can remain running Frequency power Default Min unit ENA normally setting range range 64 NICE2000 User Manual Instruction of function parameter O interior figure setting Operating l pans Default 0 00Hz Min unit 0 01Hz running eee setting range range o o0Hz Fo 04 OoOO O O 04 This function code is valid only when F0 01 0 It sets up the initial default of speed when the elevator is controlled by panel operation Once the value is set up it can never be lost even when electric is cut off User can change this function code to change the running speed
34. DC 0 10V 4 20mA input Analogue input determined by jumper J3 of control boar Al2 GND terminal 2 2 Input impedance voltage input 100KQ current input 500Q DI1 COM Digit input 15 1 Optocoupler isolation double polarity DI2 COM Digit input 16 input Ray DI3 COM Digit input 17 2 Input impedance 3 3KQ Digit input DI4 COM Digit input 18 3 Input voltage range 0 30V terminal Digit input 19 Can be used as high speed pulse input DI5 COM high speed channel besides characteristics of pulse DO1 D04 Analogue 1 Output voltage or current determined AO1 GND Analogue output l output by jumper J4 in control board 26 NICE2000 User Manual Installation and Wiring Terminal Terminal K Sort A Function instruction sign name 2 Output voltage specification 0 10V 3 Output current specification 0 2mA DO1 CNICE Analogue output _ Optocoupler isolation double polarity open circuit collector output type Output voltage specification 0 24V Output current specification 0 50mA Digit Note CME and COM is isolated inside output FM COM Reservation but CME and COM have jump out DO1 default 24V driven when DO1 wants to use exterior power drive the outside jumper between CNICE and COM should be cut off Normal close Contact driving capacity T A T B Terminal AC 250V 3A Cos 0 4 Relay DC 30V 1A output Normal open f T IA T C f Relay output Y12 function setup T
35. Data Please contact with agent or Err 21 i Data of encoder abnormity spillage factory Err 22 Reserved Short circuit BN Please contact with agent or Err 23 Output short circuit to ground fault to factory 122 NICE2000 User Manual Fault Diagnosis and Countermeasures Operate Fault 3 panel ee Fault cause Disposal way k description display ground Err Reserved 24 29 1 Detect safety circuit and Er 30 Safety The signal of safety circuit is look over its state rr circuit off cut 2 Detect that exterior power supply is natural or not 1 Check if the drive chain is Drive chain TE ruptured Err 31 Drive chain is ruptured i off 2 Check if the drive chain protection act 1 Check if the contact is Contact __ _ Contactor burn out the contact burned out or not Err 32 conglutinati ke dust conglutination 2 Check if the contact on feedback switch gets stuck 1 Check if the brake can not open really Err 33 Brake fault Open brake fault 2 Check if the brake protection switch cannot act 1 Check if the left handrail Left handrail runs at abnormal speed The speed of left handrail Err 34 speed 2 Check if the left handrail i shows abnormity abnormity speed test sensor works abnormal 1 Check if the right handrail Right runs at abnormal speed handrail The speed of right handrail Err 35 i 2 Check if the right handrail speed shows ab
36. F9 Group Assitant management parameter 0 0 88 6 10 F9 Group Protection function parameter 0 ee 89 6 11 FA Group Communication parameter eee 93 6 12 FB Group Elevator special function setting 0 94 6 13 FC group Additional function parameters eeeeeeee 102 6 14 FF Group Factory parameter reserved 104 6 15 FP Group User parameter ineen 104 Chapter 7 Typical application and adjusting of system 108 7 14 Typical application of bypass variable frequency 108 7 2 Typical application of complete variable frequency 112 7 3 Adjusting procedures 0 c cccccecseececeeeeeeeeeeaeeeeeeeeeeeees 114 Chapter 8 Fault Diagnosis and Countermeasures 120 8 1 Fault information and solutions ee eee eeeeteeeeeeneeees 120 8 2 Common faults and disposal cccceseeeeceeeeeeeeeeeeees 124 Vi Safety and Precautions Safety and Precautions NICE2000 User Manual Chapter 1 Safety and Precautions Safety definition There are two kinds of safety tips ASpanger Failure to follow these instructions will result in death or serious injury PP caution Failure to follow these instructions will result in medium hurt and equipment damage 1 1 Safety information 1 1 1 before installation A oancer e Do not use the controller that is damaged or has defect Otherwise it may cause
37. NICE2000 User Manual Foreword Foreword NICE2000 is a modularized and high powered elevator integrative controller which is developed independently by Suzhou Monarch control technology Co Ltd It represents the future development trend and can satisfy the variety needs of different factories Compared with the traditional general type controller it has compact structure more convenient installation method What is prior its advanced motor control arithmetic motor parameter auto tuning static tune and complete tune run contactor control brake contactor control bypass variable frequency energy saved control complete variable frequency energy saved control speed track control are incomparable Particular functions like run contactor contact detection brake contactor contact detection touch conglutination detection up and down light electricity signal left and right armrest signal step loss detection provide the most dependable guarantee for the safe movement of the elevator Moreover the special single key design of NICE2000 elevator control system makes the complicated keyboard operation much more easier it can use the general terminal RJ45 to connect to any position of the operation panel that enables the adjust of the elevator convenient and simple Main features Integration Perfect combination of drive and control NICE2000 elevator control system gathering all functions of motor driving part and control logic par
38. Note In stop or run display interface press QUICK to enter quick menu and press UP DOWN to select different parameters then press ENTER to enter the next level menu here the changing method is the same with that in third 39 Operation and Test run of controller NICE2000 User Manual level menu Press QUICK to back to last screen and the changed parameter will not be saved 4 4 3 Delete the parameter in the quick menu There are parameters as FO 00 F1 11 F4 13 and F8 03 in quick menu If you want to delete F4 13 please operate as the following Run or Flash display in stop display QUIC ENTE 50 00 gt upo 00 HA ofi HA urgi PRS upti3 R uFs 03 t ee Fig 4 8 Deletion of shortcut menu Note Press PRG in the quick menu with displayed contents flashing which prompt the user to delete this parameter or not then press ENTER it will delete the parameter in the menu and the contents will stop flashing so that the whole operation finished While pressing QUICK it will cancel the operation and the displayed parameter stops flashing If the last parameter is deleted NULL will be displayed that means no parameter is stored in the menu 4 5 Password setting In order to protect the parameter more effectively NICE2000 provides the password protection The figure below shows how to set the password to 12345
39. Runtime to act Defaul Min 4 selection t unit 85 Instruction of function parameter NICE2000 User Manual Setting range 0 1 This function code defines the elevator s running state when the runtime has reached the time set by F7 02 0 continue to run 1 stop Electrify to ground short protect detection Setting range 0 1 This function code can determine if elevator control system has grounding short fault when detect motor after electrifying If this function is valid then elevator will begin detection when electrifying instantly if the system has grounding short fault it will close off output at once and export Err 23 0 forbid 1 eee Brake use rate _ use rate Ga an F7 07 Ea Setting range range Ea 100 When under complete convert frequency mode if elevator runs downgrade motor will have energy feedback leading to bus voltage hoist Here the system needs to collocate brake resistance F7 07 can adjust brake effect of the brake unit Faneto Name Setting range Default Min unit code F7 08 softwere 00 00 999 99 00 00 0 01 edition 1 F7 09 Sowas 00 00 999 99 00 00 0 01 edition 2 Zales cores fo re temperature F7 08 and F7 09 display the software number used in the integrity F7 10 displays the radiator s temperature 86 NICE2000 User Manual Instruction of function parameter es code a Seat 11 Terminal oe state ane F7 11 and F7 12 are used to i
40. The installation steps are reversed to teardown steps Note please keep the down cover plate away from falling when teardown it to avoid equipment damage and human injury 3 2 Electric part installation 3 2 1 Selecting instructions of external electric components Table 3 1 Input f Output Vacancy Contact main ae Control Earth Type MCCB or circuit SR ia wire line i circuit wire A A wire mm mm mm mm NICE E A 4013 32 25 6 6 1 4 NICE E A 4017 40 32 6 6 1 4 NICE E A 4025 63 40 6 6 1 4 NICE E A 4032 63 40 6 6 1 4 20 NICE2000 User Manual Installation and Wiring Input Output Vacancy Contact main an Control Earth Type MCCB or circuit ERAKETA wire line circuit wire A A wire mm mm mm mm NICE E A 4037 100 63 10 10 1 NICE E A 4045 100 63 10 10 1 NICE E A 4060 125 100 16 16 1 3 2 2 Instructions of using the external electric components Table 3 2 Name Installation position Function Air circuit Forefront of input Cut off the power and provide short breaker circuit protection This switch is essential 7 Switch on off to operate controller Between air circuit Avoid the contactor s frequent switch Contactor breaker and input on off to control the electric power side of controller directly 1 Improve input power factor 2 Eliminate high frequency harmonics in i
41. This function code cannot be changed in operating state and can only be changed when the controller is stopped 4 3 2 Switch the state display parameters by shift key gt gt gt Aim frequency gt DC bus voltage gt AIl AI2 Fig 4 4 example of state display parameter switch LED can display several status parameters when NICE2000 is in stop and running states Detailed parameter content can refer to parameters F7 00 running parameter F7 01 stop parameter Through key user can shift the display in sequence and display the stopping or running state 37 Operation and Test run of controller NICE2000 User Manual parameters circularly In stop state there are 4 parameters for NICE2000 and user can shift to display the parameters circularly by key The parameters are aim frequency DC bus voltage Al1 and Al2 Whether to display the status parameters is dependent on the bit setting of F7 01 through the key user can shift the display in sequence and display the selected parameters In running state there are 12 parameters running frequency aim frequency DC bus voltage output voltage output current Al1 Al2 etc whether to display the status parameters is dependent on the bit setting of F7 00 through the key user can shift the display in sequence and display the selected parameters 4 3 3 Error information reading
42. alid in deceleration a foo Surge restrain F3 04 0 100 gain F4 Group Input function parameters 0 no function Select terminal X i F4 01 1 N O input of safety 6 01 circuit signal 2 N O input of x En inspection signal 3 N O input of up EAA Select terminal X motion 3 3 02 4 N O input of down motion s47 x x x w Xx Function Parameter Table cote mame setngrenge F4 03 F4 04 F4 05 F4 06 Select 03 Select 04 Select 06 Select 07 Select 08 Select 09 Select 10 Select 11 terminal terminal terminal terminal terminal terminal terminal terminal terminal 48 NICE2000 User Manual NICE2000 User Manual Function Parameter Table Code name seumgrange Select terminal X F4 12 12 Select terminal X F4 13 13 Select terminal X F4 14 14 Select terminal DI F4 15 i Select terminal DI F4 16 2 Select terminal DI F4 17 terminal DI F4 18 terminal DI F4 19 F4 20 Reserved Reserved 49 Function Parameter Table NICE2000 User Manual Safety brake delay 0 65535 ms time Frequency tracing error auto reset resetting Time limit for frequency tracing Time multiple for the first time Ai apex selection 1000 1600 Assistant function 0 65535 selection Max delayed time 2 000 10 000s for in phase switch Stable speed F4 29 de
43. ance selecting 2 only valid when decelerated can greatly reduce the possibility of the over voltage fault alarm but at the circs of having brake resistance or quick decelerate unnecessary please select 1 whole process valid F3 04 oscillating restrain gain when motor has no oscillating phenomena please select the parameter to 0 Only when motor have obvious oscillating 70 NICE2000 User Manual Instruction of function parameter and cannot run normally propriety increase of this function can restrain the surge efficiently Setting method of the parameter choose as small as possible amount at the premise of effective restrain the motor oscillating 6 5 F4 os Ta function EA eee a I kee setting range 1 1 Set sensitivity of the input terminal If digit input terminal is liable to suffer interference then arose malfunction to raise the parameter will enhance anti jamming capacity but meanwhile it will decrease sensitivity of the input terminal code range zo nega a te 26 1 0 46 selection EA ree 3 1 0 46 selection Fana M A ena 4 1 0 46 selection Pao eee 30 1 0 46 selection panga I gt 1 1 0 46 selection ea eee 31 1 0 46 selection paz I S eee 33 1 0 46 selection F4 08 X 08 terminal 1 0 46 selection aoe Aeon 19 1 0 46 selection F4 10 X 10terminal 15 1 0 46 selection F4 11 X11 terminal 71 Instruction of function parameter NICE2000 User Manual selection CT
44. ch from high speed running to stop directly 2 Quick slow cycle When setting the elevator s energy save mode if there are no passengers after a period of time the elevator will switch from high speed running to slow speed running 3 Quick slow stop cycle When setting the elevator s energy save mode if there are no passengers after a period of time the elevator will switch from high speed running to slow speed running first and if still no passengers enter the elevator will finally stop When NICE2000 is driving in Y A running its energy save mode can only be quick stop cycle When in bypass convert frequency FB 16 can select 1 2 or3 FB 16 is working together with input terminal energy save selection of NICE2000 The detailed combination and relative effect is in next table Energy Energy save save mode Effect Remark terminal FB 16 Invalid 0 1 2 3 No energy save 1 Elevator is at manual state 98 NICE2000 User Manual Instruction of function parameter Energy Energy save save mode Effect Remark terminal FB 16 effect 2 Running direction is determined by terminal up and down 3 Keep high speed running after startup 1 Elevator is at automatic state 2 Running direction is determined by Avail 0 Denar terminal up and down effect 3 Keep high speed running after startup 1 Elevator is at automatic state 2 When FB 17 0 ru
45. convert freq Slow quick cycle V VF Run VVF Run Tres Fig 7 11 Complete variable frequency quick stop cycle energy save curve 113 Typical application and adjusting of system NICE2000 User Manual 7 3 Adjusting procedures Pihanga DANGER Please make sure the escalator is in inspection running state and keep people away from it Failure to follow this instruction will cause serious accident In order to be convenient for adjust this chapter was written according to the normal sequence of lift adjustment When the periphery circuit and machine installed are finished completely you can finish the elevator s basic adjust gt check before slow car run to ee ea ok parameter involved FO parameter setting Fo model to determined f Pe e i pi ignal t to determined F4 parameter setting q Ol Fe19 sign ype to de ermine Foti motor parameter a ri 0i Fi 1ol____ refer to F1 11 in chapter 6 1 FE parameter setting FEO BE 2L e poting condition to A F m i Fi g refer to 7 3 2 inspection trial run EA 4 ye ed i r function adjusting eritua iSe comfort adjusting refer to F4 FG Fd 7 3 1 Check before slow state adjustment Correct adjust is the safeguard of elevator s normal running Before electric adjust please check whether it is allowed to be adjusted and assure the spot safety When adjusting at least two workers should be on the spot and cut off the power
46. ction of F6 11 0 1 4 inspection mode 12 L 13 NICE2000 User Manual ae om 100MS 0 01Hz 0 Max frequency 0 Max frequency 0 Max frequency 0 500MS 0 01Hz 0 01Hz MS 1s 4 0s o gt 0 10 00Hz 0 01Hz 1 50Hz 0 10 00Hz 0 01HzZ 1 50HZ Assistant function parameters 1 16383 Bito frequency 1 0 1s 0 00 Max frequency 0 01Hz running Bit1 aim frequency Bit2 DC bus voltage Bit3 output voltage Bit4 output current Bit5 Al1 52 NICE2000UserManual s SSS SSSS SSCSCSCSCC Functtion Parameter Table User Manual Function Parameter Table Senmgrange Min petat operation Bit6 Al2 Bit7 low bit of input state Bit8 high bit of input state Bit9 output state Bit10 host motor pulse number Bit11 handrail speed time interval Bit12 step loss time interval Bit13 in out state displa 1 255 BitO aim frequency Bit1 DC bus voltage Bit2 Al1 Bit3 Al2 Bit4 pulse number of F7 01 Stop paame mainframe display Bit5 interval of handrail speed test Bit6 interval of step missing Bit7 input output state display Running time 0 60000hours X setting Cumulate working F7 03 0 65535hours hours F7 04 0 3600 Run time to action 0 continue to run selection 1 stop Electrify to ground 0 invalid F7 06 short protect 1 avail 53 Function Parameter Table NICE2000 User Manual detection F7 07 ca o 100 me cad Software 000 00 999 99
47. ctory default of NICE2000 is set based upon bypass variable frequency parameter So users just need to input the nameplate parameter to F1 group according to the actual motor configuration 7 1 3 Running curve In the bypass variable frequency control the energy save running curve is shown in next picture 110 NICE2000 User Manual Typical application and adjusting of system Speed fork freq Run Work freq Run High Low Photoelectric 0 a PERSEE Tk Freq change Freq change Bypass convert freq Times Slow quick cycle Fig 7 4 Quick slow cycle energy save curve Speed Work freq Run Work freq Run High Photo electric Low 0 Freq change Freq change Bypass convert freq Tes Slow quick cycle Fig 7 5 Quick slow cycle energy save curve Seed Work freq Run Work freq Run High es Photo electric Low o die i a ers i Freq change Freq change Tirreis Bypass convert freq Slow quick cycle Fig 7 6 Quick stop cycle energy save curve 111 Typical application and adjusting of system NICE2000 User Manual O MCTC TRB A in phase switch card aT B Fig 7 7 MCTC TBB A synchronous switch card There are 7 input terminals on synchronous switch card R S T 10V AI1 Al2 GND and 2output terminals U V among them R S T U V contact to R S T U V on the inverter respectively 7 2 Typical application of complete VF Complete variable frequency is that the elevator is controlled by inver
48. danger 1 1 2 when installation PB cancer Please install on objects which are not combustible such as metal and keep away from combustible substances Otherwise it may cause fire ae Do not leave wiring terminal or screw in the controller Otherwise it will cause damage to controller e Install the controller at the place where there is less vibration and avoid strong sunshine 1 1 3 during wiring N banger Only the qualified electrical engineer can perform the wiring Otherwise there will be unexpected danger NICE2000 User Manual Safety and Precautions Pe A circuit breaker must be installed between the electric power and the controller Otherwise there will be danger of fire Wiring can only be done after the electric power is cut off Otherwise there will be danger of electric shock Please connect the controller to the ground according to the standard Otherwise it may cause an electric shock e Do not connect the input terminals with the output terminals U V W Otherwise the controller may be damaged Ensure the wiring meet the EMC requirements and the slow safety standard Please refer to the as to the wire size Otherwise accident may occur 1 1 4 Before power on a Please confirm the mains voltage level is consistent with that of the controller and the input R S T and output U V W wiring are correct and check if there is a
49. e Every change to the rated power F1 01 the system will recover parameter F1 06 F 1 10 to default 6 3 F2 Group Vector control parameter Frequency tracing respones factory default 30 Min unit 1 F2 00 speed Setting range 0 100 The system will trace the frequency from the F6 02 when the motor switch from working freq to variable freq drive and the tracing response speed is depend on F2 00 the recommended value of F6 02 is 50 Hz and the parameter is set among 20 50 Note frequency tracing will stay at F6 02 when the parameter was set as 0 and until the tracing is ok same as the original way 67 Instruction of function parameter NICE2000 User Manual Freq tracing constant Factory 060s Min unit 0 01 F2 01 speed delay default time Settinfg range 0 01 10 00s When the escalator switch from the work freq to variable freq it will run with the constant freq as tracing The motor will run at decrese freq after the F2 01 setting time this parameter needs no modification code range F2 02 Switching frequency 1 2 00Hz 0 01Hz aay F2 03 Proportional gain of speed 30 1 0 100 loop 2 F2 04 Integration time of speed 0 805 0 015 0 01 10 00 loop 2 s F2 05 Switching frequency2 5 00Hz o 01Hz 7027F0 04Hz Freq tracing f F Default Min unit 1 current setting setting range 50 130 The system will trace the freq with the current of F2 06 This parame
50. ected the output current reaching to F9 01xmotor rated current and last to the end of anti time limit curve fixed time it will export Err 11 Over voltage lose speed anomoyar ain 1 voltage lose g speed 100 F9 04 Over ae speed 130 120 150 F9 05 Over current lose speed 0 100 gain Over current lose speed 150 4100 200 point Over voltage lose speed gain It can adjust inverter s ability to restrain over voltage lose speed The value of this parameter and the ability is in direct ratio 89 Instruction of function parameter NICE2000 User Manual For small inertia load the value should be small otherwise the system dynamic will become slow accordingly For big inertia load the value should be large otherwise it will influence the restrain effect and may cause over voltage fault Over voltage lose speed point It can select function protection point of the over voltage lose speed The inverter will start to perform over voltage lose speed protection when exceeding this value Over current lose speed gain It can adjust inverter s restrain over current lose speed ability The value of this parameter and the ability is in direct ratio For small inertia load the value should be small otherwise the system dynamic will become slow accordingly For big inertia load the value should be large otherwise it will influence the restrain effect and may cause overOcurrent fault Over current lose speed poi
51. edition ZK 1 Software 000 00 999 99 edition DSP 2 Radiator 0 100 C temperature Terminal input state Terminal output F7 12 i state F8 Group Assistant management parameters Switch coefficient F8 13 0 13 of up in phase Es Switch coefficient F8 14 of down in phase F9 Group Protect function parameters Overload 0 forbid F9 00 protection i 1 permit selection Overload F9 01 protection 0 20 10 00 oaa F9 02 Reserved 50 100 1 Over voltage stall O no over voltage a gain stall 100 F9 03 Over voltage stall F9 04 120 150 1 130 point Over current stall F9 05 0 100 gain Over current stall 100 200 1 150 point Non stop of Instant 0 forbid F9 07 stop function 1 permit F9 08 Decline frequency 0 00HzZ s Max 0 01Hz s 10 00HZ s 54 NICE2000UserManual s sSSSSS SCSCC Functtion Parameter Table User Manual Function Parameter Table Input phase failure O forbid select 1 permit Eero instant stop i Ma EEN failure select 1 permit 0 no error 1 inverse unit protection 2 accelerated over current 3 3 decelerated over current 4 A constant over current 5 accelerated over voltage 6 j decelerated Information of first over yo tage 7 constant a over voltage 8 controller power fault 9 under voltage fault 10 inverter overload 11 motor overload 12 phase failure of input side 13 phase failure of output side 14 module overheated 15
52. ee or at least set grater than FC 04 10 Ea switch FC 01 wiser e ia oms vmu ims Setting range range 0 700ms Used for the up switching point judgment when the switching condition is ready and after this parameter time delay the system shall switch from the convert freq to work freq Ke a switch FC 02 a aii oms minut ime Setting range range 0 700ms 102 NICE2000 User Manual Instruction of function parameter Used for the down switching point judgment when the switching condition is ready and after this parameter time delay the system shall switch from the convert freq to work freq Switch aa FC 03 nan seee oe o imme Setting range range 0 12000 This parameter is read only which is used for check switching point coefficient this switch value should not be too great when the running direction is same and the error range should within 100 myriabit is neglectable Switch coordinate default Min unit Ears This parameter is read only switch the lowest point of sync signal this point parameter must be smaller than FC 00 to assure the smooth switch generally this parameter is set around 280 oe signal FC 05 ace ee oms minut ime Setting range range 0 700ms This parameter is read only switch the sync signal changing cycle generally is about 650ms New switch adjusting method 1 This parameter is only valid in bypass convert f
53. en function code value is 1 suppose elevator runs down 6 2 F1 Group Motor parameter Funcuon Name Default Min unit setting range code F1 01 Rated power PePendon sy 2 2 75 0kW the model Rated current PePend On ooa 0 00 655 00A the model F1 04 fared 50 00Hz 0 01Hz 0 00 99 00Hz frequency Please set according to the motor nameplate parameter It needs exact motor parameter to achieve good performance of NICE2000 parameter automatic distinguish is provided Exact parameters distinguish function needs the right setting of the motor rating parameter n code F1 06 Stator resistance 0 0019 0 001 30 0000 66 NICE2000 User Manual Instruction of function parameter n code EZA model F1 07 Rotor resistance E ooo 0 001 30 0000 E model F1 08 Leakage Dependon OotmH 0 01 300 00mH inductance the model F1 09 uua Dependon fo tmH 0 1 3000 0mH inductance the model F1 10 No load current DPePend on 0 01A 0 01 300 00A the model To ensure the system performance please collocate the machine according to the system standard If the motor power is too much different from standard motor it may lower the performance If the automatic tuning of the motor is completed normally the setting values in F1 F6 to F1 F10 will update automatically If the motor tuning cannot be finalized automatically refer to the congener motor with same parameter and input the data by hand Not
54. energy save running through these two signals Energy save selection valid indicates that the controller is in the automatic running state 13 N O input of left handrail speed 14 N O input of right handrail speed The running speed of the left right armrest strap is separately monitored to avoid the elevator stop running when the armrest appear abnormity and output 73 Instruction of function parameter NICE2000 User Manual alarm 15 N O input of up step loss 16 N O input of down step loss Up down step of the running process is separately monitored to avoid the elevator stop running when the step loss and output alarm 17 N O input of variable frequency speed selection When the elevator needs diverse speed the signal can adjust the speed selection by hand only the quick running state When this signal is valid the quick frequency of NICE2000 is the setting parameter of quick 2 frequency This function is valid both in the bypass variable frequency and complete variable frequency 18 N O input of driving mode selection This signal can select elevator Y A circs running with high PRI when the signal is effective even if FO O1set up to bypass variable frequency or complete variable frequency NICE2000 will come into elevator Y A circs running 19 N O input of fire signal When have fire alarm this signal can cut off lift running signal 20 N O input of fault reset External fault reset terminal signal 21 N O
55. erate without braking resistance Invert frequency work frequency redundancy design NICE2000 elevator control system has complete variable frequency control bypass variable frequency control Y A control etc multi control modes and inside placed abundant elevator control function and utmost satisfy the usage need of different customers reduce fault stop rate also provide more flexible choice to customer Energy saving usage When the elevator is in the state of standby and speedup it uses frequency conversion control while in stable operation it adopts frequency control This kind of intermittent working can surely save energy Professional quality Specialized manufacture platform The manufacturing platform of the NICE2000 adopts specialized streamline It adopts the standardized work specification perfect management system advanced control and strict product examination system in the production line Independent wind channel design three defend processing The internal PCBs of NICE2000 all introduce three defend painting craft and the whole series adopt the independent wind channel design raising the stability of NICE2000 circulate over long term in the elevator automatic sidewalk in different application circumstance Meet EMC standard It has advanced lightning proof design inside which raises the credibility of the NICE2000 User Manual Foreword system consumedly Moreover NICE2000 elevator co
56. erminal i determined by F5 12 parameters Function a J1 28 core terminal special interface card m expansion card Auxiliary j J2 PG card PG card special interface interface ENS Outside bring Outside bring keyboard keyboard parameter copy unit interface 3 I O extend board terminal configuration CM1 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 RX RX CM2 Y9 Y10 Y11 XIXI IXIXIXIXI XIXI XI X X X X X DC D 11 2 3 4 5 6 7 8 9 10 11 12 13 14 C 4 Function instruction of I O expansion board terminal Sort Sign Name Function instruction NICE2000 adopts exterior 24V power Power External connect ae i DC DC usually used as digit input terminal work supply 24V power power 27 Installation and Wiring NICE2000 User Manual Sort Sign Name Function instruction x1 Digit input 1 X2 Digit input 2 X3 Digit input 3 X4 Digit input 4 X5 Digit input 5 Digit X6 Digit input 6 1 Optocoupler isolation low level input is ingui X7 Digit input 7 avail terminal X8 Digit input 8 2 Input impedance 3 3KQ X9 Digit input 9 3 Input voltage range 0 30V X10 Digit input 10 X11 Digit input 11 X12 Digit input 12 X13 Digit input 13 X14 Digit input 14 Y1 CM1 Relay output 1 Y2 CM1 Relay output 2 Y3 CM1 Relay output 3 Y4 CM1 Relay output 4
57. f damageable units of controller The damageable parts include the cooling fan and filtering electrolytic capacitor whose life is highly related with the operating environment and maintenance Table 2 5 Component Lifetime Cooling fan 2 3years Electrolytic capacitor 4 5years User can confirm the replacing period according to the operating state 1 Cooling fan Possible damage causes bearing attrition and blade aging Judging criteria if there is crack on fan blade or abnormal vibration noise at start 2 Electrolytic capacitor Possible damage causes poor quality input electric power high ambient temperature big pulsating current due to frequent load fluctuation electrolyte aging Judging criteria No liquid leak protuberant safety valve and electrostatic capacitance test and insulation resistance test 2 7 3 Storage of controller The following points must be followed in controller storage 1 It is recommended to store the controller in its original packing box 2 Long term storage will cause deterioration of electrolytic capacitor Therefore the controller must be power on at least once within 2 years and for at least 5 hours to restore the capacitors of the controller and the input voltage must be boosted gradually with voltage regulator to the rated value 16 Installation and Wiring Installation and Wiring NICE2000 User Manual Chapter 3 Installation and Wiring Do open the packi
58. f the rectifying bridge has been exploded please seek technical service c Check if the CHARGE indicator is on If the indicator is off the fault will be in the rectifying bridge or the buffering resistance part If the indicator is on then the fault may be in the switch on off part please seek technical service 2 Air switch trips off after power on a Check if short circuit or grounding phenomenon exists in the input power b Check if the rectifying bridge has been destroyed if it is broken seek professional help 3 Motor s refusal to work after the inverter is running 124 NICE2000 User Manual Fault Diagnosis and Countermeasures a b c 4 a b c Check if there is balanced three phase output between the U V and W If there is the motor wiring has been damaged or the motor is blocked up due to mechanical cause There is output but three phase is not balanced It means that the inverter drive board or the output modules are damaged Please seek help If there is no output the inverter drive board or the output modules are damaged Please seek help Inverter work normally after power on but the air switch jump after running Check if there is short circuit between output modules If there is seek help Check if there is short circuit or grounding between the motor wiring If there is seek help If tripping happens occasionally and the distance between motor and inverte
59. g code unit range After NICE2000 control system has power on host motor pulse step loss pulse handrail pulse should be monitored in order to discover the hidden safety trouble so that ensure the normal running of elevator When NICE2000 control system begins to run every time it will first pass the time defined by FB 00 and then starts to detect relative mainframe speed test step loss armrest speed test If FB 00 0 0 NICE2000 will not monitor the pulse signal Function ama Default wiin Setting code unit range FB 01 Error range of host 30 20 20 99 motor speed test FB 02 Error range of armrest 30 20 20 99 speed step loss These two function codes reflect the error range of host motor speed test and armed speed step loss and respectively work together with FB 03 and FB 04 Suppose FB 01 is set to 30 and FB 03 is 32 the system will alarm if detecting 23 41 pulses per second otherwise it will not give alarm code unit range Host motor rated pulse 0 200 S FB 03 has defined the pulse number per second when the elevator is running in rated rotate speed Via this function code NICE2000 judges if the mainframe is running in normal state It is normal if the output pulse number is within 20 of setting range or it will arouse the alarm If FB 03 0 NICE2000 will not do the mainframe pulse signal test If the machine reaches high speed running in bypass convert frequency mode user can inquire about host moto
60. g under Y A control mode FB 18 defines the required time from Y type toA type code unit range mode 0 Invalid 1 Continue work 2 Short time work If elevator appears over speed reversion or drive chain s disconnection phenomena NICE2000 control system will carry through safety arrester control according to FB 19 User can make selection base to the characteristic of the safety arrester code unit range Safety arrester act ia 4 0 10s keep time If the action electromagnetic iron of safety arrester is working in short time FB 19 will select 2 At this time NICE2000 will export output safety arrester act keep time of FB 20 101 NICE2000 User Manual Instruction of function parameter code unit range Er Comparison table of input and output In the next picture every digital pipe has its own meaning light on input output point is valid detailed information is listed below X2 X3 X4 X5 a a ry a X8 x9 x10 X11 X12 X13 X14 DII Y3 Y4 Y5 Y6 Y7 Y8 9 Y10 LED 1 LED2 LED3 LED4 The input and output state is shown in above picture with specific meaning of every pipe lined out 6 13 FC group Additional function parameters Sync switching default 300 Min unit point setting Setting range 200 2000 it is used to set the convert freq and work freq switching coordinate point the following function code FC 01 and FC 02 are based on FC 00 which is adjusting fr
61. ge among the lines 31 Installation and Wiring NICE2000 User Manual 1 Factors influencing leakage current to earth and solution There are distributed capacitance between lead and earth The more the distributed capacitance is the larger the leakage current will be to minish the distance between the controller and motor will reduce the distributed capacitance The higher the carrier frequency is the larger the leakage current will be we can reduce carrier frequency to reduce leakage current but remember that it will increase the motor noise Adding reactor is also an efficient way to resolve the leakage current 2 Leakage current will be increased with the increase of loop current therefore large motor power will lead to corresponding large leakage current 3 Factors influencing leakage current among the lines and solution There exists distributed capacitance among the controller output lines if the current passing circuitry has high frequency harmonics resonance will occur and then lead to leakage current Using thermal overload relay here will cause malfunction The resolvent is to reduce carrier frequency or to add output reactor It is not suggested that to add thermal overload relay in the front of motor when using the controller use the electro over current protective function of the controller 32 Operation and Test run of controller Operation and Test run of controller NICE2000 User Manual
62. ght is normal or not or survey if signal output terminal have voltage or not 5 Check before high speed On the basis of examine running renew the escalator to normal state and test running circs at hand and auto state separately examine item by item according to the parameter setting 117 Typical application and adjusting of system NICE2000 User Manual 118 Fault Diagnosis and Countermeasures Fault Diagnosis and Countermeasures NICE2000 User Manual Chapter 8 Fault Diagnosis and Countermeasures NICE2000 controller has about 40 pieces of alarm information or protection functions in total The system controller monitors all kinds of input signal run condition exterior feedback information If it abnormity happens the relevant fault protection functions can react with fault code displayed 8 1Fault information and solutions If fault alarm information is shown in the controller the system will deal with the problem based on fault code User can construe fault by suggestive information at this section to find out fault cause and its resolvent Operate Fault f panel oe Fault cause Disposal way 1 description display 1 Main loop output is 1 Obviate exterior problems grounding or short wiring such as connection 2 The connection of traction 2 Add reactor or output filter Inverse unit mats Err01 machine is too long 3 Inspect the wind channel protection ae ir 3 Work conditio
63. he switches such as contactors are connected between the output terminal and the motor make sure to start and stop the controller when the controller Safety and Precautions NICE2000 User Manual has no output otherwise the modules in the controller may be damaged 1 2 7 Usage beyond the range of rated voltage NICE2000 controller shall not be used out of the specified range of operation voltage Otherwise the internal components of the controller may be damaged If needed please use corresponding voltage regulation device to change the voltage 1 2 8 Change three phase input to two phase input Do not change NICE2000 control system three phase to two phase Otherwise there will be malfunction or controller damaged 1 2 9 Lightning proof There are lightning proof devices inside the controller and can protect itself from some inductive thunders but the user should install other lightning protection device at the front of the controller if lightning strike occurs frequently 1 2 10 Altitude and de rating use When the altitude is higher than 1000m the cooling effect is deteriorated because of the rarefaction of air the de rating method must be used Please refer to our company for detailed technical support 1 2 11 Some special usages If customer needs to use other wiring methods beyond the graphs in the manual please contact our company 1 2 12 Disposal of controller The electrolytic capacitors in the main circuits and PC
64. i iiiad 14 2 7 Daily maintenance of controller 0 0 c ccceeeeeeeeeeeeeeeeee 15 Chapter 3 Installation and Wiring s ssusssnssensnnnnnnnnnnnnnnnnnnnnn 18 3 1 Mechanical installation 18 3 2 Electric part installation 1 20 3 3 The solution for EMC problem sieer 30 Chapter 4 Operation and Test run of controller s ss 34 4 1 technical terms of NICE2000 controller eee 34 4 2 Introduction of operation and display panel ee 35 4 3 Function code examine amp operation instruction 36 4 4 Operation mode of shortcut MENU ee eeeeeeeeeeeeeeees 38 4 5 Password Setting aisoissa iii 40 Chapter 5 Function parameter Table csssesssseeeeeees 44 5 1 Instruction of function parameterS ceceeeeeeeeeeeeees 44 5 2 Function parameter table ccccccceeeeeeeeeeceeeeeeeeseaeees 44 Chapter 6 Instruction of function parametel secsseeee 64 6 1 FO Group Basic parameter cne 64 6 2 F1 Group Motor parameter 66 6 3 F2 Group Vector control parameter ee eeeeeeeeeeees 67 6 4 F3 Group Motor control parameter cere 69 Foreword NICE2000 User Manual 6 5 F4Group Input function parameter eeen 71 6 6 F5Group Output function parameter 78 6 7 F6 Group Elevator basic parameters 0 ccceeeee 81 6 8 F7 Group Assistant function parameter eee 84 6 9
65. il mode according to different petrol pump 0 The oil mode is not controlled by the controller and oil cycle time is determined by petro pump itself 1 5 This oil mode adapts to pulse petrol pump only the setting value is pulse interval of pulse pump oil and complete one cycle with parameters set by FB 06 and FB 07 There are three main modes of petrol pump 1 one is petrol pump with persistent electricity whose oil time and cycle time are totally controlled by 97 Instruction of function parameter NICE2000 User Manual itself here FB 15 is set to 0 2 this kind of pump will keep working once has electricity whose oil time and cycle time are controlled by the controller here FB 16 is set to 0 3 the last one can only work with pulse supply whose oil time and cycle time are controlled by the controller For example when the petrol pump is under pulse supply state select FB 15 2 FB 16 60 FB 07 4 It means that after continuous work for 48 hours the elevator will carry through oil output with the mode get electricity gt 1s interval gt 2s get electricity again 1s jinterval 2s thus after the above cycle for 60s it will stop oil finally In this period the pump gets supply for 20 times Function Name Defa Min Senra rane code ult unit g g selection 0 Invalid 1 Quick stop cycle When setting the elevator s energy save mode if there are no passengers after a period of time the elevator will swit
66. il the controller automatically or by hand 13 Fault output It is valid when NICE2000 has error 14 Integrative preparation ready When the controller is well prepared the relay is in N C output state while when the power supply is cut off or error happens the relay is in N O output state 15 Start up contactor When the lift is running the output will start up the connector In the other hand when elevator stops it will cut off the exported 16 Rapido running state output When the elevator is in variable frequency or A running state this signal will be output 17 Slow running state output 79 Instruction of function parameter NICE2000 User Manual When the escalator is accelerating decelerating or slow climbing or in examine this signal is exported code Output mode 65535 1 0 65535 selection Output mode selection is used to set the type of every output point whether N O or N C 0 N C output 1 N O output Assistant brake contactor BitO Unused Bit7 output Bit1 Running contactor output Bit8 a Blakes colada Bit2 Up NET contactor output Bit9 Up direction output Down NET contactor Bit3 Bit10 Down direction output output Bit4 Y type running contactor Bit11 Buzzer output output Bit5 Atype running contactor Bit12 Oil output output Bit6 Brake contactor output Bit13 Fault output F517 Adbias oo ow F5 18 eof meee fe PP we
67. ime limit it will be forced to work frequency Generally speaking this parameter is adjusting free code range Stable speed delayed time for 0 500s 0 001s 0 2 000s synchronous switch When the variable frequency switching to rated stable state factory default is 51 5 Hz and after the time set by this function code considering it has stable speed then judge the switch condition Generally speaking this parameter is code Er Filter times of synchronous card 0 001s analogue sampling This parameter multiplying 2 equals to the filter time unit Ms in order to s77 Instruction of function parameter NICE2000 User Manual enhance the interference proof capacity Generally speaking this parameter is adjusting free 6 6 F5Group Output function parameter code range F500 DO output selection of 1 oom Y1 function selection F506 Ye function selection 6 1 oom F510 _ v10 function selection 9 1 oo DO1 is digit output terminal and the interface is open circuit collector mode Y1 Y12 are relay output terminals and among them Y1 Y11 are relay output terminals of the expand I O control board of NICE2000 and Y12 is main control board relay output These output terminals can select corresponding function code 1 17 Each function is denoted by its code 00 No function To set unused terminal with no function can avoid unintended action 01 Running contactor Used for the contacto
68. it1 aim frequency Bit3 output voltage 84 NICE2000 User Manual Instruction of function parameter Bit4 output current Bit10 pulse number of host motor Bit5 Al1 Bit11 time interval of handrail Bit6 Al2 speed test Bit7 low bit of input state Bit12 time interval of step loss Bit8 high bit of input state Bit13 input output state Bit9 output state NICE2000 uses the shift key to display the above parameters one by one in running process eer lel F7 01 in ose ae Setting range range lia This function can control the display of 8 parameters in stop state and each parameter is controlled by one bit binary code 1 display this parameter 0 don t display this parameter For example if F7 01 is set to 15 the elevator can monitor 4 kinds of parameter state through shift key on operating panel BitO aim frequency Bit5 time interval of handrail speed Bit1 DC bus voltage test Bit2 Al1 Bit6 time interval of step loss Bit3 Al2 Bit7 input output state Bit4 pulse number of host motor eter time eau F7 02 toa Ea Setting range range a 60000 When the accumulated work time exceeds setting value of F7 02 elevator will follow the work mode set by F7 05 If F7 02 parameter is set to 0 this function will be invalid ea faecal F7 03 ea hours Eg Setting range pea 65535 It reflects the elevator s actual running time and this function is read only parameter so that user cannot modify F7 05
69. layed time for 0 2 000 0 001 0 5s in phase switch Filter time for F4 30 in phase analogue 1 5 1 5 sampling F5 Group Output function parameters F5 04 Select function of 0 no function 1 running contactor 2 up motion NET contactor 3 down motion NET contactor 4 Y running contactor 5 A running contactor ps e 50 NICE2000 User Manual Function Parameter Table a Select function of function of HA o F5 16 Select output type 0 65535 F5 18 AO gains 10 00 10 00 0 running frequenc AO output ave sf F5 19 i 1 output voltage selection 2 output current F6 Group Start stop control parameters variable frequency F6 00 to work frequency 0 2 0s switch time Work frequency to F6 01 variable frequency 0 2 0s switch time 51 Function Parameter Table code mame us jida Conversion switch 0 50 0Hz 0 frequenc Quick 1 running frequenc Quick 2 running Fi frequenc Slow F runnin F g F6 06 frequenc Star triangular switch of time extension Examining and repairing F6 09 F6 10 frequency Inching examine and repair 6 6 6 6 accelerate time 6 0 0 0 0 Up frequency switch surplus Down frequency switch surplus F7 Group Running F7 00 parameter display F6 07 Accelerate time 0 0 3000 0s F6 08 Decelerate time 0 0 3000 0s 0 2 3 4 5 Sele
70. mended to increase this parameter vice versa When the torque hoist is set to 0 inverter becomes automatic torque rising With regard to the torque hoist frequency if the setting is within the frequency range the torque is valid while if the setting is beyond the frequency range the torque hoist is invalid 69 Instruction of function parameter NICE2000 User Manual output voltage f fb output frequency V1 hand torque rise voltage Vb max output frequency fi torque rise shut off frequency fb basic running frequency 6 3 Hand ean ae torque cr conpton ee in range range 0 0 200 EEA AVR select Defaut 1 min unit 2 A ronge EA 1 2 EEEN gain setting range EA 00 F3 02 Slip compensation is effective for V F control To set this parameter can compensate the slip load when it is V F controlled minishing the change of motor rotation generated due to the variation of the load generally 100 corresponds to rated slip when the motor with rated load We can adjust slip coefficient referring to following principle when slip compensate coefficient is set up to 100 with rated load the rotation of the inverter motor is basically close to given speed If with lower load this coefficient can be less than 100 and if with lager load this coefficient can also be larger than 100 F3 03 AVR automatic steady voltage function select In the V F control mode when need quick stop but without brake resist
71. monitor the motor running speed When host motor test speed pulse shows abnormity NICE2000 will protect it consequently ensure the elevator safety After this signal receives sensor signal which is transmitted by the motor it will judge the speed of operation 06 N O input of contact conglutination signal Monitor the overall work contactor to avoid the elevator s next running when any of the contactors has conglutination fault 07 N O input of drive chain detect Drive chain s rupture will directly threaten the running safety of the elevator and it is also one of the important conditions of additional safety arrester brake work NICE2000 controller judges drive chain abnormity or not according to this input 08 N O input of brake detection Open or close work arrester brake will directly influence the normal work To avoid motor running with brake the detection is necessary 09 N O input of non reversion detect In order to avoid non operate reverse protection the test can effectively avoid the situation of up process reverse to downgrade but it doesn t need to consider in the state of downgrade 10 N O input of up photo electricity 11 N O input of down photo electricity 12 N O input of energy save selection Energy save switch is used to set the elevator state at hand or automatic At the state of automatic energy save up down photoelectricity detect switch can monitor the passengers NICE2000 dispose automatic
72. n 5MQ 1 2 2 Thermal protection of motor If the rated capacity of the motor selected is not matching that of the controller especially when the rated power of the controller is bigger than that of the motor make sure to adjust the parameters for motor protection inside the controller or to install a thermal relay to the motor to guarantee the protection to the motor 1 2 3 Run above work frequency Please don t use it above work frequency If user sets the frequency above 50Hz running please take the equipment intensity and duration into your account 1 2 4 Motor heat and noise Since the output voltage of the controller is in PWM wave with some harmonics the temperature may raise the noise and vibration may slightly increase compared with the controller running at main frequency 1 2 5 Pressure sensitive device or capacitor at output side Since the controller outputs PWM wave the capacitor used for improving power and pressure sensitive resistor used for lightening proof shouldn t be installed at the output side of the controller otherwise the controller may have transient over current and may be damaged 1 2 6 Switches Used at the Input and Output terminal of the Controller If the contactor is required to be installed between the controller and the power supply it is prohibited to start or stop the controller with this contactor Frequent charge and discharge will shorten the life of capacitor in the controller If t
73. n Defa Min Setting Name code ult unit range entering If NICE2000 control system is running in energy save mode and there are passengers entering into elevator in reversed direction the elevator will accelerate to high speed with buzzer ringing If there are no passengers within the setting time the elevator will run in energy save mode or stop running Reg RA Ea Setting Name Reg el is EET FB 12_ Assistant brake time_ Assistant brake time 0 41 9 95 9 9S _FB 13 _ Brake open detect time Brake open detect time EENET 0 5 9 9S 96 NICE2000 User Manual Instruction of function parameter brake detect point FB 12 and FB 13 are two parameters of NICE2000 to control the brake FB 12 is functionary time of assistant brake output terminal If after system output opening the brake but the brake doesn t release after setting time FB 13 it will export brake fault Fig 6 5 Brake output sequence chart Function Nees Defa Min TE code ult unit g g Examine stop 1 5s 0 1s 0 9 9S delayed time If the elevator drive mode is Y A when in examine running it may cause frequent start stop of examine and motor damage due to stop Increasing FB 14 interval time can solve this problem It should be done to prolong FB 14 time first after every stop then enter the next examine Rea eed a Setting Name ee a aus FB FB 15 Oil mode selection e e This function code is aiming to select o
74. n is too hot and fan 4 The connections inside the 4 Please contact with agent or controller become loose factory 1 Main loop output is i 1 Obviate exterior problems grounding or short wiring Accelerated such as connection Err02 2 If the motor has done over current i 2 Motor parameter tuning parameter tuning of not i 3 Lighten sudden adding load 3 Load is too heavy 1 Main loop output is grounding or short wiring 1 Obviate exterior problems 2 f the motor has done such as connection Decelerated Err03 parameter tuning of not 2 Motor parameter tuning over current 3 Load is too heavy 3 Lighten sudden adding load 4 Decelerate curve is too 4 Adjust the curve parameter steep 1 Main loop output is 1 Obviate exterior problems Constant grounding or short wiring such as connection Err04 speed over i 2 If the motor has done 2 Motor parameter tuning curren parameter tuning of not 3 Lighten sudden adding load 120 NICE2000 User Manual Fault Diagnosis and Countermeasures Operate Fault panel ee Fault cause Disposal way S description display 3 Load is too heavy 4 Select proper encoder and 4 Pulse wheel encoder adopt shielded cable interference is too strong 5 Properly increase F6 02 1 Input voltage is too high a a 1 Adjust input voltage 2 Lift inverse pull is serious 2 Adjust the elevator startup 3 Brake re
75. ng and check the controller before installation Please confirm these information listed below carefully 1 Check that if the model and the rated power is complied with your order Your ordered machine product certification user manual and warranty card will be in the package 2 Check if the machine is broken during the transportation if there is any miss or damage please contact with our company or agent as soon as possible Note Installation and wiring should strictly comply with the criterions in chapter 1 3 1 Mechanical installation 1 Installation environment a Temperature The ambient temperature will bring great affect to the life of controller The allowable extent is 10 C 50 C b Mount the controller on incombustible surface such as metal with enough space to spread heat And use screw to mount it vertically on the bracket c Mount the controller at places with less than 0 6G vibration Never near punch and kindred equipment d Avoid places with direct sunshine or dampness e Avoid place with corrosive flammable explosive gas f Avoid places with oil dirt dust or metal powder 2 Installation position 18 NICE2000 User Manual Installation and Wiring Fig 3 1 installation position Instruction When the controller power is less than 22kw the size of A can be left out of account and when the controller power is more than 22kw A shall be bigger than 50mm Heat dissipation is a
76. nly in high speed running BIT3 0 Alarm only once when having fault 1 Impulse alarm when having fault BIT4 0 Alarm at once when having fault 1 Alarm only when having successive faults Bit 5 0 if the system can not trace the frequency after 15s E41 tracing error reported 1 Err01 Err 07 occur the system will restored and startup with slow car speed after F4 23 s setting time If no such errors there is no frequency tracing anymore and system turn to slow car startup Bit 6 reserved Bit 7 0 reversion judgment through reversion switch 1 reversion judgment through 2 photoelectricity signals A and B WIRING A connected to D15 terminal and B connected to D11 terminal Function selection of D11 F4 15 needs no settings Bit 8 0 up down command need only touching off signal 76 NICE2000 User Manual Instruction of function parameter 1 the up down signal should be valid all along the system will stop running when the key startup signal is invalid Bit 9 0 the original mode 1 the new switching software is start F8 13 14 invalid only related to FC 00 FC 05 BIT 10 0 armrest band lag judgment only 1 select armrest signal to judge over speed and lag code range Max delayed time for 3 0005 0 001s 2 000 10 0 synchronous switch 00s When variable frequency switching to the work frequency record time after F4 29 has made delayed time stable If the proper condition never exists within F4 28 t
77. nning direction is determined by terminal up and down 3 When FB 17 1 running direction is Kyai 1 Quick stop cycle determined by terminal up energy save photoelectricity and down photoelectricity 4 When elevator is in quick and stop state conversion the corresponding state keep time is determined by quick keep time FB 09 1 Elevator is at automatic state 2 When FB 17 0 running direction is determined by terminal up and down 3 When FB 17 1 running direction is determined by terminal up photoelectricity and down Quick slow cycle as Avail 2 photoelectricity but under this mode energy save elevator will not stop so the direction will not change 4 When elevator is in quick and slow state conversion the corresponding state keep time is determined by quick keep time FB 09 and slow keep time FB 10 99 Instruction of function parameter NICE2000 User Manual Energy Energy save save mode Effect Remark terminal FB 16 1 Elevator is at automatic state 2 When FB 17 0 running direction is determined by terminal up and down 3 When FB 17 1 running direction is determined by terminal up Quick slow stop photoelectricity and down Avail 3 cycle energy save photoelectricity 4 When elevator is in quick slow and stop state conversion the corresponding state keep time is determined by quick keep time FB 09 and sl
78. normity i speed test sensor works abnormity abnormal 1 Check if the up step running speed is abnormal or lost Err 36 Up step loss Up step loss i 2 Check if the up step loss sensor works abnormal Down step 1 Check if the down step Err 37 Down step loss f loss running speed is abnormal or 123 Fault Diagnosis and Countermeasures NICE2000 User Manual Operate Fault 3 panel ot Fault cause Disposal way S description display lost 2 Check if the down step loss sensor works abnormal 1 Check if the motor works Mainframe The speed of mainframe is well Err 38 speed test Fault abnormal 2 Check if the mainframe au speed sensor works well 1 Check if reverse will happen Err 39 Anti reverse Prevent down running in up in the up running process rr fault running process 2 Check if anti reverse switch work well When A running switch to Motor speed i i Err 41 variable frequency running Properly reduce F6 02 tracker fault the tracking process intermits 8 2 Common faults and disposal The following faults may occur during the use of the inverter please refer to the methods described below to perform the fault analysis 1 No display after power on a Check if the input power supply of the inverter is consistent with its rated voltage through multimeter If there is something wrong please remove it b Check if three phase rectifying bridge is intact I
79. nput side protect the rectifier x F bridge AC input pat ata 3 Eliminate current unbalance due to reactor controller i input phase unbalance If after DC reactor installed these demands can not be met yet select AC reactor 1 Improve input power factor 2 Eliminate high frequency harmonics in input side NICEZOODconoler A ai nna baran at alot o DC 7 5 30KW ae AC reactor reactor DC reactor F standard DC reactor which has smaller size and do not lower voltage in the loop so it is recommended to select DC reactor Our company adopts this kind of reactor as standard component 21 Installation and Wiring NICE2000 User Manual Name Installation position Function There is always high frequency harmonics at output side of controller When the distance between controller and motor is too far there will be some distributed capacitance in the circuitry Some harmonics may be generate resonance causing influence in two aspects Between output side A of controller and C output 1 Destroy motor insulated capability reactor motor and near and may cause damage to motor controller 2 Generate big leakage current bringing forth controller continual protection If the distance between the controller and the motor is more than 100m it is recommended to install the AC output reactor 3 2 3 Electric connection Make sure to do the wiring operation when the power supply switch is
80. nspect the input and output state of elevator control system NICE2000 elevator control system operating panel has 5 LED display from right to left separately is LED4 LED3 LED2 LED1 LEDO0 light on valid signal Terminal input state F7 11 is defined as follows A Safety l Brake A Up step lost loop signal inspection B P nepa Non reversion B Down step lost signal inspection C Up C Speed sae selection of C Up motion photoelectricit i variable y frequency LEDO De Down LEDit PP LED Didrvng mode photoelectricit motion y selection E Speed test E Energy E Fire reset of mainframe save selection F Contactor F Left conglutinatio handrail F Fault reset n speed R ADe G Right eine handrail G Stop signal chain speed Terminal output state F7 12 is defined as follows 87 Instruction of function parameter NICE2000 User Manual A Running A Safety inspection contactor B Up B Non reversion contactor inspection C Down C Up photoelectricity contactor A D Y D Down a running photoelectricity F B Epo neeo LED m E A E Energy save E G running selection C contactor a F Brake F Left handrail speed D output contactor G Assistant G Right handrail brake speed contactor 6 9 F9 Group Assistant management parameter code unit range
81. nt It can select function protection point of the over current lose speed The inverter will start to perform over current lose speed protection when exceeding this value code aa F9 07 Non stop of Instant 1 0 1 stop function Decline frequency 10 00Hz 0 00Hz s F9 08 rate of non stop of i Is 0 01Hz s Max instant stop frequency s Non stop of Instant stop function This function indicates that the inverter will not stop when power is cut off instantly Under the situation of instant power off or sudden reduced voltage the inverter s output speed will slowdown so that compensate the reduced voltage through load feedback energy It can make inverter continue to run in short time Decline frequency rate of non stop of instant stop It is used to set drop value of the inverter output frequency 90 NICE2000 User Manual Instruction of function parameter If the value as well as the load feedback energy is too small low voltage compensate can t be carried out If the value as well as the load feedback energy is too large over voltage protection cannot be achieved Please lt a this parameter IA according to the load inertia Se range When system selects automatic fault reset it is used to set the time of automatic reset The system will wait for resetting if exceeding this value 0 no automatic reset function ea aad range ES 100 i It is the os time from fault alarm to automatic reset of the
82. nth error bus voltage o F9 37 The tenth error terminal input F9 38 F9 40 The tenth error terminal input 7 a N 0 00Hz 99 0 Hz 0 999 9V 1 1 oso 1 O O o o oa o oO oO oa oa 1 0 01 Hz 0 01A 0 1V Pe ene 0 014 a 92 NICE2000 User Manual Instruction of function parameter cg ee ES p Name mra range kea _ state state2 ooo oar Te tenth error terminal Peeran 065535 65535 E eal oe ee The tenth error fault frequency 0 000 a _Fo 44 The tenth error bus voltage o o 1v o s99 0v_ Fo a5 Reversa Sf tt omz _Fo46 Reversa St tt o2s9 _Fo a7 The last error information o f 1 oso F9 48 The last error terminal input 1 0 65535 state 1 The last error terminal input 1 0 65535 state 2 The last error terminal output 1 0 65535 state 0 01 0 00Hz 99 0 Last error fault frequency 0 000 _Fo 53 Error bus vottage o ov o o 9v Fosa Reversa of 1 om2 Foss Reversa Stott o29 This group parameter can record the latest 11 fault information and fault occurring time Fault information displays fault code As to the detailed type and their significations please refer to chapter 8 6 11 FA Group Communication parameter Refer to NICE2000 Communication Protocol 93 Instruction of function parameter NICE2000 User Manual 6 12 FB Group Elevator special function setting Function Name Default win Settin
83. ntrol system has super strong anti interference ability meet the harsh EMC standard Please read this manual carefully before you use the NICE2000 elevator control system The contents of the manual has already confirm before sending to press But our company is making every effort to the continuously perfection and improvement of the production so we the reserve the rights of modifying product specification function and other contents of this manual If there is any change we won t give prior notice Suzhou Monarch Control Technology Co Ltd provides all directions technical support for the customers If there is any question please contact with Monarch product sale center or the customer service center Thank you for your consistent support to us Foreword NICE2000 User Manual NICE2000 User Manual Foreword Contents ae 0 0 E A T eee l Chapter 1 Safety and Precautions cccsseecssseeeeeseeeeeeeeees 2 1 1 Safety information psan e 2 1 2 Cautions i a E a E E SE 5 Chapter 2 Product Information sssssssssussnnsnunnnnnnnnnnnnnnnnnnnnnnn 10 2 1 Name designation rules cccccceseeeeeeeeeeeeceeeeeeeeeeeeees 10 2 2 Nameplate ne ia e a dh ete eaaa 10 2 3 Controller models rniret a nti t eataa 11 2 4 Technical Specification ccccccccccseececeeeeeeeenteeeeeeeeeeeees 11 2 5 Product appearance and installation holes dimension 12 2 6 Option UNIS aiseid eieie
84. ny short circuit in peripheral circuit and if the wiring is fixed firmly Otherwise the controller may be damaged Every part of the controller had passed the dielectric strength test at factory Please do not do this test again by yourself Otherwise accident may occur Poong Please mount the cover plate properly before power on the controller Otherwise accident may occur All of the wiring should comply with the instructions of the manual and make sure connect the circuitry correctly Otherwise accident may occur 1 1 5 After power on Poara Do not open the cover of the controller after power on Otherwise there will be danger of electric shock Do not touch the controller and its circuit with wet hands Otherwise there will be danger of electric shock Do not touch the controller terminals Otherwise there will be danger of Safety and Precautions NICE2000 User Manual Ponge electric shock At power on the controller will perform the security check of the external heavy current circuit Do not touch U V W terminal or motor connection terminal otherwise there will be danger of electric shock a If parameter identification is required please pay attention to the possible injury that may occur due to the rotating motor Please do not change the factory settings otherwise the equipment may be damaged 1 1 6 When running PBs sencor Do not touch
85. o 13 groups Each group has several function codes The function code uses 3 level menu with the format F X XX which means No XX function code in group X For example F 8 08 means the No 8 function code in group F8 In order to make functional code setting convenient the function group number corresponds to first level menu the function code number corresponds to second level menu and function code parameters correspond to third level menu 2 The contents of function codes Column _1 function code means the serial number for function parameter group and parameter Column 2 name means the complete name of the function parameter Column 3 setting range means the parameter setting range Column 4 minimum unit means the minimum unit of the parameter setting Column 5 factory setting means the original default Column 6 operation means the modification attributes of the parameters whether to enable the modification and the modification requirements Instructions are listed below yw the parameter can be modified while the NICE2000 is running or stopping x the parameter can not be modified while the NICE2000 is running e the parameter cannot be modified for it is actually measured and recorded 3 Factory Default means the numeric value after the function code parameter is refreshed when recovering the default parameter but the actually measured value or recorded value will n
86. ork state according to feedback signals to State monitor A ensure the escalator work effectively Switch input 19 switch input terminal input specification 24V 5mA Souu 12 relay output with corresponding function setup l O interface VEe OARRA neatly 2 analogue input terminals 1 analogue output Analogue terminal 5 bit LED display with operating speed and bus Display and Operation panel voltage parameters keypad Computer monitor Monitor the parameters in all states Altitude Lower than 1000m Ambient 10 C 40 C ambient temperature is temperature within40 C 50 C duration is required re 5 environment Humidity Less than 95 RH without condensation Less than 5 9m s 0 6g Storage 20 C 60 C temperature 2 5 Product appearance and installation holes dimension 2 5 1 Serial Product appearance 12 NICE2000 User Manual Product Information up cover plate operate panel down cover plate bar code function input output hole bottom installation hole fan inverter nameplate Fig 2 2 size and installation holes dimension 2 5 2 Installation holes dimension Table 2 3 Gross A B H Ww D aperture a Controller type weight mm mm m mm mm mm kg NICE E A 4013 148 236 246 158 165 95 4 4 NICE E A 4017 NICE E A 4025 150 335 348 223 177 096 5 10 NICE E A 4032 13 Product Information NICE2
87. ot be refreshed 4 The controller provides password protection of function code to protect the parameters effectively detailed in Chapter 4 5 2 Function parameter table 5 2 1 Groups of function parameters Press PRG buttons and then UP DOWN button all of the displays are first level menu which are group of function Details as follows 44 Operation and Test run of controller FO Basic parameter F1 motor parameter F2 vector control parameter F3 VF function parameter F4 input function parameter F5 output function parameter F6 up down control parameter F7 assistant function parameter 5 2 2 Function parameter table NICE2000 User Manual F8 auxiliary parameter F9 protect function parameter FA communication parameter FB elevator function parameter FF factory parameter FP user parameter managing FO Group Basic parameter F0 00 Reserved foz O operating control 1 bypass Elevator drive panel variable frequency 2 full frequency driving 3 Y Adirect startup Frequency power F0 02 interior digit setting setting mode variable Operating panel 0 00Hz F0 04 0 01Hz 0 00Hz frequency FO 04 Max frequency 50 00Hz 99 00Hz 0 01Hz 50 00Hz 0 5 16 0kHz 0 1kHz Panel controlled F0 06 i 0 1 1 reverse running F1 Group Motor parameter eid i F1 01 Carrier frequency Rated power 2 2 75 0kW F1 02
88. ow keep time FB 10 Function Name Default Min Setting code unit range FB 17 Automatic function 1 0 1 selection 0 Half automatic run mode It means that elevator can only run in one direction NICE2000 will decide the running direction of elevator according to input terminal signal This function is valid in energy save mode when FB 16 0 FB 16 energy save selection mode As to detailed information of running direction refer to the next table Up signal Down Running direction of emei signal NICE2000 Avail Invalid Up direction Avail Avail Invalid Stop running Invalid Invalid Invalid Stop running Invalid Avail Down direction 1 Complete automatic run mode It means that elevator can run in both 100 NICE2000 User Manual Instruction of function parameter directions When elevator is in waiting state the photoelectricity signal which acts first will determine the current running direction For example up photoelectricity valid indicates that there are passengers entering from underside so the elevator will come upward On the contrary down photoelectricity valid means that there are passengers entering from downside so the elevator will come downward Under this mode running direction will not be influenced by up down direction however it need up down signal to touch off to start up H keg ge Fe 1s Y A switch time ps tt If NICE2000 is workin
89. r s impulse number every second by the shift key gt gt 94 NICE2000 User Manual Instruction of function parameter Function Defa Min Setting Name code ult unit range FB 04 Handrail speed pulse oda Gis 0 0 99 99s interval NICE2000 is carrying though handrail speed impulse test according to FB 04 If the interval is more than setting time it may arouse the alarm And the corresponding time of FB 04 is the handrail speed impulse interval when elevator is running in rated speed If FB 04 0 NICE2000 will not do the handrail pulse signal test If the machine reaches high speed running in bypass convert frequency mode user can gt about handrail s impulse interval by the shift key gt gt Eg iea E Setting Name E ga E range FB 05_ Step lose pulse interval Step lose pulse interval 0 00s o1s 0 0 99 99s Similar to handrail speed pulse interval NICE2000 is carrying through step loss pulse interval according to FB 05 If the interval is more than setting time it may arouse the alarm And the corresponding time of FB 05 is the step pulse interval when elevator is running in rated speed If FB 05 0 NICE2000 will not do the step loss pulse signal test If the machine reaches high speed running in bypass convert frequency mode user can inquire about step s impulse interval by the shift key gt gt Function Defa Min Setting Name 5 code ult unit range FB 06 nelalng
90. r is quite long consider add output AC reactor 125
91. r of inverter s output side 02 up contactor 03 down contactor During the work frequency running unconverted frequency running up down contactor can control the running direction of the elevator 04 Y running contactor 05 A running contactor When use six level motor Y A contactor is used for motor wiring control A contactor applies to double speed bypass variable frequency system and 78 NICE2000 User Manual Instruction of function parameter standby Y A system While the Y contactor is only suitable for Y A system 06 Brake contactor output Brake output contactor can release the arrester of motor thereby it allows the motor operation 07 Assistant brake contactor This function supplies strong signal of the brake contactor 08 Security brake contactor When the height of escalator is raised H gt 6m additional safety arrester should be outfitted When facing the situation of drive chain rupture or anti reverse switch act the elevator will begin reversion or run exceeding 1 3 times of rated speed then the security arrester act 09 Up direction indicate output 10 Down direction indicate output They are used for direction indicator with it passengers can identify direction when they are hitching escalator 11 Buzzer output In the case of escalator startup fault or having reverse passenger buzzer is playing an important role 12 Oil output Oil output controls lubricate pump and can o
92. rea 5 bit LED display it can display various monitor data and alarm codes such as setting frequency output frequency 3 Instruction of units HZ frequency unit V voltage unit 35 Operation and Test run of controller NICE2000 User Manual percentage A current unit RPM rotation speed unit 4 Instruction of buttons on keyboard Table 4 1 Keyboard function Key Name Function O Enter and exit the first level menu and delete quick PRG Program key parameter i Enter the menu level by level and set parameter ENTER Confirm key conformation A Increase of data and function code V Decrease of data and function code Select the display parameters circularly at stop state and Shift key running state Select the modification bit when modifying parameters Start up the machine in the terms of keyboard operation STOP RES Stop the machine when the controller is in running Reset Stop Reset key ET the machine when in the state of fault alarm R Enter or exit the first level of quick menu Refer to QUICK Quick key QUICK operation instruction Multi function MF K Display and remove error information selection ke 4 3 Function code examine amp operation instruction 4 3 1 Operation flow of 3 level menu NICE2000 adopts 3 level menu to conduct the parameter setting It s convenient to query and modify function code and parameter 3 level menu include function parameter group
93. repair work to the controller since there still exist high voltage at filter capacitor after the power supply is switched off in a short time Wait until the light CHARGR off and the bus voltage is lower than 36V _ Daily check items Check if there is any abnormal noise during the running of the motor Check if there is strong vibration of motor Check if the installation environment of controller changes Check if the cooling fan of controller works normally VV VV Y Check if the controller is over heated 2 Daily cleaning gt Always keep the controller in a clean state gt Clean the dust on the controller and prevent the dust especially the metal powder gt Clean the oil dirt in the cooling fan of the controller 2 7 2 Periodical maintenance It focuses on the places that can be hardly checked during the daily check 1 Periodical maintenance items gt Check the air channels and clean them periodically Check whether the screws are loose Check whether the controller is rusted Check whether the input output terminals have scratch or pulling trace Insulation test in main circuit VVV Vv 15 Product Information NICE2000 User Manual gt Note Insulation test use 500V Mega Ohm Meter should be done separately after disconnecting the input power cables from the controller Dielectric strength test is not necessary since this test had been done at factory 2 Replacement o
94. req 2 Switching method details see Fig 6 7 below ek lt gt lt a Fig 6 7 sync signal cycle 103 Instruction of function parameter NICE2000 User Manual 3 Firstly choosing FC 01 or FC 02 for adjusting on the basis of running direction Starting adjusting from 0 and add 100 each time 0 100 200 300 400 500 600 respectively then select the best one After this done the fine tuning by add or reduce 20 to select the most appropriate parameter 4 Judging the correctness of FC 03 FC 04 FC 05 set the change of FC 03 at the same direction as criteria changing range should smaller than 100 FC 04 should smaller than 300 FC 05 should around 650 5 Please check F4 29 F4 30 F6 12 F6 13 or sync card wiring and sync card condition for FC 03 FC 04 FC 05 abnormal 6 14 FF Group Factory parameter reserved 6 15 FP on User ane Ee Ea __FP 00__ ___User password She Set it as any number except zero so that the password protection function is valid 00000 eliminate the former user s password value and make password protect function invalid When user password is set and become effective NICE2000 will forbid examining the parameter Please fix your 2 If mis setting or a contact with EJ es eS FP Parameter update jews tee one 0 No operation 1 Inverter will resume all the parameters to factory default 2 Inverter will eliminate the latest fault record Eee ey
95. reserved Fault reset 0 1 100 0s interval 55 Function Parameter Table NICE2000 User Manual 16 reserved 17 contactor fault 18 current detection fault 19 motor tuning fault 20 encoder fault 21 data overflow 22 reserved 23 short circuit to ground fault 24 29 reserved 30 safety switch OFF 31 driving chain OFF 32 contact conglutination of contactor 33 brake fault 34 speed abnormal of left handrail 35 speed abnormal of right handrail 36 up step loss 37 down step loss 38 speed test fault 39 non reversion fault 41 track failure of rotation speed 40 42 50 reserved Time of the first F9 14 Reserved 1 error t Information of the F9 15 0 50 1 x second error Time of the second F9 16 Reserved 1 error 56 NICE2000 User Manual code Name oes Ensa Information of the F9 17 0 50 third error 9 19 5 Time of the third F9 18 Reserved error Information of the F 0 50 fourth error The fourth error F9 20 Reserved time Information of the 0 50 fifth error Time of the fifth F9 22 Reserved error Information of the 0 50 sixth error 50 Time of the sixth Reserved error Time of the Reserved seventh error Information of the Information of the 0 seventh error Time of the eighth F9 28 Reserved error Information of the 0 ninth error Terminal input F9 30 state 1 of the ninth 0 65535 error Terminal input F9 31 state
96. signation rules NICE E 1 A 4017 NICE series elevator integrated controller Output current 3 phases 400 v Escalator specialized New structure 2 2 Nameplate MODEL NICE E 1 A 4017 POWER 7 5kW INPUT 3PH AC380V 20 5A 50Hz 60Hz OUTPUT 3PH AC380V 17A ona 20h S N i 10 NICE2000 User Manual Product Information 2 3 Controller models Power Input Output Output NICE2000 model Input voltage capacity current current power KVA A A KW NICE E A 4013 8 9 14 6 13 0 5 5 NICE E A 4017 11 0 20 5 17 0 7 5 NICE E A 4025 17 0 26 0 25 0 11 Three phase380V NICE E A 4032 21 0 35 0 32 0 15 Range 15 20 NICE E A 4037 24 0 38 5 37 0 18 5 NICE E A 4045 30 0 46 5 45 0 22 NICE E A 4060 40 0 62 0 60 0 30 Basic Specification 2 4 Technical Specification specification Max output 90Hz frequency 0 5K 16K Hz carrier frequency can be adjusted Carrier frequency _ automatically according to the load characteristic Speedup down S Curve can be set flexibly curve 40 kinds of protective functions as Electrify short Fault protection circuit survey input output phases loss protection over current protection prevent reversion etc 11 Product Information NICE2000 User Manual specification equipment safety detection like grounding short circuit etc auto check Judge the w
97. sistance is too Accelerated oo time sequence Err05 much or brake unit is over voltage 3 Select proper brake abnormal i resistance 4 Accelerate curve is too 4 Adjust curve parameter steep 1 Input voltage is too high 2 Brake resistance is too 1 Adjust input voltage Er06 Decelerated much or brake unit is 2 Select proper brake rr over voltage abnormal resistance 3 Accelerate curve is too 3 Adjust curve parameter steep 1 Input voltage is too high hatte Constant f 1 Adjust input voltage 2 Brake resistance is too Err07 speed over te 2 Select proper brake much or brake unit is voltage resistance abnormal 1 Input voltage is too high 1 Adjust input voltage Controller Err08 2 Drive control panel is 2 Please contact with agent or power fault abnormal factory 1 Transient power cut exists 1 Obviate exterior problem of Err09 Under 2 Input voltage is too low power rr voltage fault 3 Drive control panel is 2 Please contact with agent or abnormal factory 1 Inspect brake loop and Inverter 1 Brake loop is abnormal Err 10 power supply overload 2 Load is too heavy i 1 Lighten load Mot 1 FC 02 setting is unsuitable 1 Adjust parameter otor Err 11 2 Brake loop is abnormal 2 Inspect brake loop and overload 3 Load is too heavy power supply Err 12 Input side 1 Input power asymmetry 1 Adjust input power rr phase 2 Diver control panel is 2 Please contact with agent or 121
98. sors which are used for measuring usually have the feeble signal around If closed to controller or in the same control panel they are liable to get interference and come into malfunction It is recommended to use following solutions keep away from the interfere power don t make the signal line parallel to the driving line and parallel enlacement together is especially prohibitive the signal line and driving line should adopt shielded cable add linear filter or wireless noise filter in the input and output side of the controller 2 When interfered equipment and controller use the same power the best bet is to add linear filter or wireless noise filter between the controller and power if the interference isn t alleviative by the above solutions 3 Earth the peripheral equipments separately which can eliminate the interference generated by grounding line s leakage current due to earthing together 2 The other one is interference produced by the surrounding equipment The ecumenical reason is that there are large numbers of relays contactors or electromagnetic arresters around the controller When facing with this kind of problem use the following methods 1 Add inrush suppresser in the equipment which produce interfere 2 Add filter at the signal input terminal of the controller 3 3 3 Electric leakage and its disposal There are two forms of electric leakage when using controller 1 leakage current to earth 2 leaka
99. t 1 running frequency FB 08 Startup buzzer keep time F6 04 fast 2 running frequency FB 09 fast running keep time F6 05 Slow running frequency FB 10 Slow running keep time Bose oe Examine aNd repair FB 11 Reverse into running time frequency FB 00 fast 1 sensor detect time FB 13 Brake open detect time FB 03 fast 1 host motor pulse FB 16 Mode of energy save selection FB 06 Automatic oil keep time FB1 Whole automatic function selection User can edit according to actual demand 4 4 1 Add shortcut menu parameters Display in stop Display flash Stop flashing PR a ENTE 50 00 S FO f FO0 00 puy F0 00 p FO0 00 Fig 4 6 setup of quick menu Note When pressing QUICK in second level menu with the displayed contents flashing which prompt the user to save the parameter into the quick menu or not then press ENTER the contents will stop flashing so that the whole operation finished While pressing PRG it will not save the parameter into the quick menu and the displayed parameter stops flashing so that the operation is cancelled 4 4 2 Modify amp retrieve the shortcut menu parameters Example change the parameters FO 00 F1 11 F4 13 and F8 03 Run or display in stop QUIC 50 00 uro o0 HA uri HA ures A ursos fA 7 v v v Fig4 7 retrieve the parameter in quick menu
100. t in the whole highly integrates the elevator control system which come to a compact structure and avoid the tedious process of choosing the logic control part and drive part respectively It accomplishes the difficult task with much lower cost and better match which originally can only achieved by two divided parts NICE2000 not only reduces periphery connection to a large extent but also reinforces the safety and the stability of the elevator Dispense with PLC and elevator control board NICE2000 control system integrates the motor control and elevator control replaces the traditional PLC or the elevator control board inverter control mode It save the PLC or elevator control board so that save the electric costs on the basis of the reliability improvement of control system Adapt to global variable standards Foreword NICE2000 User Manual With many years professional experience in elevator control system NICE2000 has considered the different standards in different countries It meets the requirement of EN115 Europe standard AS1735 Aussie standard A17 1 America standard PUBEE Russia standard K Korea standard Hongkong and Singapore s special requirements Bypass invert frequency Dispense with braking resistance NICE2000 elevator control system has original bypass variable frequency of the integrated control technology taking full advantage of operation and making conversion elevator control op
101. ter in accelerate decelerate constant speed process The difference is that when in constant speed power supply of bypass variable frequency is driven by work frequency while complete convert frequency is totally driven by convert frequency Complete variable frequency also can achieve multi speed selection function When input terminal variable frequency speed selection is valid elevator will choose quick 2 frequency as aim frequency so that meet with different user requirement 7 2 1 connection mode System connection A Fa Les iJo o a 112 NICE2000 User Manual Typical application and adjusting of system Fig 7 8 Complete variable frequency main circuit connection Besides terminal connection mode refers to Fig 7 2 and Fig 7 3 7 2 2 Parameter setting To set F0 01 to 2 means that complete variable frequency drive then input the nameplate to group F1 parameter according to actual motor configuration 7 2 3 running curve Sosed VWF Run VWF Run High mO WF Run Photoelectric Low o Times Completet convert freq Slow quick cycle Fig 7 9 Complete variable frequency quick slow cycle energy save curve VVVF Run Photo electric Completet convert freq Slow quick cycle Fig 7 10 Complete variable frequency quick slow stop energy save curve Se High r ee Photo electric Low o Completet
102. ter needs no modification een a coefficient etaut F2 07 ees petaut minune ots setting range range tice 5 00s This function code is the filter time of ASR output torque current current sampling and speed feedback Generally speaking we don t need to adjust the parameter when there is strong interference just add time constant The output of speed regulator refers to the torque current command to the controller The filter time constant of speed loop refers to the filter time of the torque current command 68 NICE2000 User Manual Instruction of function parameter When the constant is big the inverter torque becomes smooth but the response becomes slow Vice versa F2 08 q setting range 0 0 200 0 It can set upper limit of torque of motor 100 corresponds to the rated torque of the motor that matches the system 6 4 F3 Group Motor control parameter rom Pe Torque hoist Defaut 10 min unit 01 F3 00 i 0 0 1 30 0 range F3 01 suey E 0 00 Max freq range In order to compensate the V F control low frequency torque characteristic some lifting compensation of the inverter output current are added If torque hoist is set too large it may cause over heated motor and over current inverter Normally do not set torque lifting over 10 To adjust this parameter effectively can avoid over current at startup of motor As to the situation of over load it is recom
103. the fan and the discharging resistor to check the temperature otherwise you may get burned Do not let unskilled technician check signal in a running controller Otherwise there will be danger of injury or damaging the equipment PB cain Do not leave objects into a running controller otherwise the controller may be damaged Donot start and stop the controller by on off of electric power otherwise the controller may be damaged 1 1 7 When maintenance Eeng Do not repair or maintain the controller with power on otherwise there will be danger of electric shock Please repair or maintain the controller after confirming the charge LED turns off Otherwise there may be human injury caused by the residual charge of the capacitor Only qualified electrical engineer can repair or maintain the controller otherwise there will be danger of human injury or damaging the equipment NICE2000 User Manual Safety and Precautions 1 2 Cautions 1 2 1 Check the insulation of the motor When the motor is used for the first time or reused after storing for a long time or in regular checkup the user must check the insulation of the motor to prevent the poor insulation of the windings of motor from damaging the controller The motor connection must be divided from the controller during the insulation check It is recommended to use a 500V Mega Ohm Meter to check and the insulation resistance shall not be less tha
104. time or 72s 1s 0 999s automatic oil FB 07 Cycie time or 167h th 0 9999h automatic oil With automatic oil function NICE2000 will carry through oil output when accumulative runtime exceeding setting time of FB 07 at this time oil output signal is valid and will disappear after the time of FB 06 This function code defines the holding time of automatic oil and time interval between two automatic oil 95 NICE2000 User Manual Instruction of function parameter Function Defa Min Setting Name code ult unit range FB 08 Holding time of startup 41 99s buzzer NICE2000 will carry through buzzer output when the direction is switching every time and the holding time of the buzzer prompt is determined by parameter of FB 08 ea Ra wea Setting Name ae Ea Ea range FB E Quick run keep time 40s 1s _10 3000s _FB 10 Slow run keeptime 60s 1s _10 3000s NICE2000 control system has energy save function which can make elevator run at quick slow stop conditions refer to FB 16 When condition is switching it can confirm the running time of NICE2000 under any work mode through FB 09 and FB 10 FB 09 is high speed running keep time of elevator control system FB 10 is only valid when quick and slow running is switching circularly when quick running is over and turn to slow running if there are no passengers it will come to stop state finally after the time of FB 10 Functio
105. type of the corresponding terminal 3 Motor tuning Choose the keyboard running mode Before motor tuning please input parameter F1 00 F 1 05 NICE2000 controller match standard based upon this nameplate 4 Check test running After above preparation we can carry through test run and the inspection speed is set by F6 09 default 25Hz 116 NICE2000 User Manual Typical application and adjusting of system 1 Input signal check Check carefully whether the action sequence of the switch signals received is correct or not safety dot input signal examine up down input signal touch conglutination signal pre reversion signal brake opening signal etc 2 Output signal check Check carefully whether the definition of MCB output terminal is corresponding to the relative contactor and whether the signal and the contact controlled by MCB output terminal work well Running contactor brake contactor etc 3 Running direction check Observe whether the actual direction is same with the aim direction direction sign of motor flywheel is significant judgment if not please change two phases of motor randomly 4 Sensor check Main motor test speed sensor left right speed sensor up down step loss sensor are important guarantee for the normal running If the running speed is abnormal after sensor detecting abnormity signal it will automatically cut off the running of the elevator Observe carefully if sensor power li
106. uick aim frequency of the bypass variable frequency is also selected according to this principle but generally in the bypass convert frequency quick aim frequency only have one so at this mode have no use for this function When the elevator running at convert frequency energy save mode with no passenger elevator will enter slow wait running at this moment slow running aim frequency is F6 05 code range F6 06 Star A switch 100Ms 1Ms 0 50Ms delayed time 82 NICE2000 User Manual Instruction of function parameter When the controller is in star A mode after FB 18 startup time the star contactor is released and then after F6 06 switching time export A contactor code range Accelerate time is the time needed from zero speedup to Max frequency Decelerate time is the time needed from Max frequency decelerate to zero tput frequency fx setting frequency time 4 i lt _ setting accelerate time setting decelerate time en actual accelerate time Refer to next fig 6 4 Fig 6 4 Accelerate and decelerate time When set frequency equals to max output frequency actual accelerate decelerate time is the given accelerate decelerate time When set frequency is less than max output frequency actual accelerate time set valuex set frequency max frequency code range Fee Inspection 25 OHz 0 01Hz 0 Max frequ frequency ency Inching examine and repair 20
107. uld be thick and short and we recommend using special yellow green cable above 4 square mm with several copper cores And the grounding resistance shall be less than 5Q Do not share the GE ground electrode and neutral line of main supply 3 2 3 3 Terminal and its wiring 1 Terminal collocation in controller circuit 25 Installation an d Wiring NICE2000 User Manual 10V Al 1 Al 2 DI 1 DI 2 DI 3 DI 4 DI5 COM GND GND AO1 CME COM DO1 FM 24V OP T A T B T C 2 Function instructions of control terminals Table 3 4 Terminal Terminal pA 5 Sort 2 Function instruction sign name 1 Supply 10V electrical power to exterior the most output current 10mA External connect 10V GND 2 Usually work as external 10V power F i potentiometer range of potentiometer resistance 1 5KQ Supply 24V power to exterior generally External connect used for digit input terminal work power Power 24V COM A 24V power and outside sensor power Max output u ee current 200mA 1 Factory default is connecting with 24V Exterior power a 2 When using exterior signal to drive the OP supply input i DI1 DI5 OP and 24V electric terminal terminal should cut off and connect with exterior 24V power Analogue input Range of input voltage DC 0 10V Al1 GND 2 P 9 terminal 1 Input impedance 100KQ Analog 1 Input range

Download Pdf Manuals

image

Related Search

Foreword foreword meaning foreword vs forward foreword reviews foreword in a book foreword vs preface foreword lyrics foreword coffee foreword synonym foreword tyler the creator foreword magazine foreword example foreword crossword clue foreword sample foreword meaning in hindi foreword tyler the creator lyrics foreword by nick santa maria

Related Contents

Trust Football edition - Brasil  ASUS T200TA User's Manual  Manual de instruções do TD-945  Wiley Using the Internet Safely For Seniors For Dummies  Craftsman TS3650 Instruction Manual  As informações e descrições dos equipamentos  FRS Discovery System OCX Control Reference Manual - I-Cube  Jeux littéraires  Web Access User Manual - James M. Wyman Ch. 13 Trustee  Instruction of  