Home
Beverage Keg Cooler OWNER`S MANUAL UBC
Contents
1. Grounded 9 Wiring diagram Evaporator fan Compressor 12 For additional information please call 1 866 995 9965 Canada 1 888 808 9286 USA East 1 866 921 1030 USA West
2. lock that cannot be opened from the inside lock bolt make sure the lock is removed disabled or destroyed before discarding This will make it impossible for children to accidentally lock themselves inside the appliance and suffocate 8 The refrigerator system of this appliance is filled with refrigerant and insulating substances which should be treated and processed separately Call your nearest service agent or specialized servicing center If you are unable to locate one contact your local authorities for proper disposal instructions Be careful not to damage the any of the refrigeration lines of the keg cooler 6 Usage instructions 6 1 Storage and handling Draught Beer should be immediately stored in a refrigerated cabinet Draught Beer products have a shelf life which on average is 30 days after the keg is tapped By keeping the beer keg pressurized with CO2 the shelf life can be extended 60 days 6 2 Beer temperature Optimum temperatures for serving cold beer are 3 5C 36 40F Temperatures too cool or too warm may cause flavor loss off taste and dispensing problems 6 3 CO2 pressure Periodically monitor the pressure regulators to ensure applied operating pressures remain constant 10 12psi lbs 6 4 Tapping keg Do not agitate kegs unnecessarily If excessive agitation occurs during transportation allow keg to settle for 1 2 hours before tapping Prior to tapping the keg ensure the beer faucet is in
3. the off position Completely remove the dust cover identification cap from the beer keg Check that the keg coupler handle is in the up off position Insert the keg coupler into the locking neck of the beer keg and apply a turn clockwise to lock into position Pull keg coupler handle out and downward until it locks into position This activates both the beer and CO2 pressure line The keg is now tapped and ready to draw beer IMPORTANT NOTICE PLEASE DON T DRINK AND DRIVE Keep beer keg refrigerated at all times Never let beer lines empty or allow them to dry out Rinse the beer glass with fresh cold water before pouring Hold glass at a 45 angle hold steady when 2 3 full start to straighten glass and top it off 9 When beer is dispensing through the faucet condensation may form on the outer surface of the faucet This is a normal condition and cannot be avoided This is caused by temperature differentials between cold beer flowing across the warmer ambient surfaces of the inner faucet Always make sure the faucet handle is pushed fully back closed to prevent excess dripping 6 5 Technical service Technical service of the keg cooler has to be conducted by trained licensed technicians who are aware of the local electrical safety rules No special equipment is required for daily service Daily service includes the following conducting visual inspection for physical damages of the keg cooler and the power cord
4. Beverage Keg Cooler KegMaster 2 OWNER S MANUAL UBC Cool Made in Ukraine PLEASE CAREFULLY READ THIS MANUAL This manual is intended for the user It describes the appliance correct installation and operating procedures for safe use Please read and follow all safety rules and operating instructions before first use of this product 1 General information about KegMaster The keg cooler is used to prevent beer in a keg from warming up in temperatures from 10 32 C 50 90F UBC Cool reserves the right to make necessary changes and modifications to the keg cooler 2 Technical parameters Outside temperature 10 32 C 50 90F The keg cooler is intended for use with a standard power line 115V 10 60Hz 15Amp Table 1 Ne Parameter Unit _ Voltage 115 60 Operating current The final temperature of the product beer in TAG 1 C 33 8 F 3 the keg depends on the position of the minimal termostat handle 8 C 46 4 F 4 4 Thermostat max min freezing 2 4 28 4 39 2 kg ft 64 141 1 Max number of beer lines 6 Dimensions without a dispensing tower Width 23 6 Depth inches 30 98 Height 39 17 Dimensions with a dispensing tower 9 7 Width 23 6 Depth inches 30 98 Height 576 Compressor capacity Capacity ofthe compressor at 10 C Wt BTU h 949 Coolant R 134A kg 1b 0 200 70 441 Output Wt 17x2 34 Evaporator fa
5. TION Selecting the proper location will ensure best performance levels of your appliance Choose a location away from heat emitting sources This appliance is designed for indoor and outdoor use This appliance should not be built in recessed unless adequate ventilation is provided to maintain proper cooling 1 Install the dispensing tower onto the top using the fasteners provided Install the faucet facing the door of the keg cooler onto the tower 2 Install manifolds onto the CO2 cylinder 3 Connect CO2 hose to the manifold and secure hose by using snap on clamps use pliers to snap the clamp tight to assure that there are no leaks 4 The length of the CO2 hose should allow reaching the coupler on a keg inside the keg cooler 5 Draw the CO2 hose into the keg cooler through a hole in the back 6 Connect the CO2 hose to the coupler and secure hose by using snap on clamps 7 Connect the beer tube to the coupler and secure hose by using snap on clamps 8 Connect the other end of the beer tube to the dispensing tower and secure hose by using plastic snap on clamps 9 Insert the free end of plastic air hose into the dispensing tower 7 10 Lock the front wheels with brakes 11 Place the keg into the cooler 12 Install the coupler onto the keg 13 Power up the keg cooler by plugging it into a power outlet If beer in the keg is already chilled it can be served at 5C 40F after 30 minutes WARNING Pl
6. checking the beer and CO2 hoses for leaks WARNING Never turn the keg cooler over It might permanently damage the compressor WARNING Pressure of CO2 must not be above 51 psi lbs 7 Emergency situations In case of a short circuit immediately cut the power and turn off the CO2 manifold 8 Spare Parts Ordering spare parts When ordering a spare part please refer to the spare part drawing and look up the specific spare part number Please state carefully the spare part number the specification and quantity wanted before you send your order If though a certain part is not specified in this section do not hesitate to contact us for further information 10 The drawing shows the standard cooler contents 2 B WDE 10 7 6 5 4 Tecumseh KARYER Drip tray Wheels KASTOR Wheels type 3104 C 080 P KASTOR Bracket door Omniatecnica Nylon bushing Lock Omiatecnica Renal Knob ter mostat cod 077B7662 Danfoss Danfoss EBM 7 16 Danube ee o O OPZ sas E amp G te Proteciverng iype22MP01060 Damhose O A Busting UALCO SK 01 7 029 RAU PV 21 Drainhose 8766 049203 001 Rehau Tyco 25 Ki Ti Car Power cod Camp E Condenser Fans ENE TK AK EE A 11 Fan motor 3 Danfoss ETC Power Cord
7. ease keep a CO2 cylinder away from the back side of the beer cooler to prevent heating up on the cylinder 5 1 Cleaning and maintenance Automatic defrosting There is no need to defrost the refrigerator because ice depositing on the evaporator is defrosted automatically Ice build up on the evaporator during compressor operation will when the compressor has cycled off defrost automatically Defrost water collects inside the drain trough and passes through the drain outlet in the rear wall into a drain pan situated above the compressor where it evaporates Cleaning the keg cooler Always disconnect the power cord before cleaning and or servicing the appliance Do not use coarse or aggressive cleaning agents as they can damage painted surfaces Clean the exterior cabinet with warm water and a mild detergent Clean the interior with warm water and mild detergent adding one or two spoonfuls of vinegar After cleaning connect the appliance to power supply SWITCH OFF AND OR DISCONNECT THE APPLIANCE WHEN NOT IN USE If you do not intend to use the appliance for long periods of time unplug the power cord Take out all foods and clean the appliance Leave the door slightly open to reduce mold mildew from accumulating inside the cabinet 5 2 Disposal of the keg cooler When your keg cooler finally wears out dispose of it in a safe and harmless manner If you have bought this appliance to replace an old one equipped with a door
8. facture s instructions f installation or operating of the product in a manner contrary to the instructions of the manufacturer g lightning fluctuations in electrical power or other acts of god This limited warranty also excludes al cost of installation disconnection or dismantling the product parts used in connection with normal maintenance such as air fitters or belts and owner required maintenance Consult the instructions enclosed with the product for information regarding recommended maintenance No one is authorized to change this limited warranty in any respect or to create any other obligation or liability in connection with this product 5 Terms of use transportation and disposal of the keg cooler Description of the keg cooler and usage instructions The keg cooler needs to be equipped with the following accessories and parts for dispensing of beer CO2 cylinder CO2 regulators air lines keg coupler beer line Beer is pushed from the keg to the dispensing tap by CO2 The pressure is set with the regulator Keg cooler assembly The keg cooler s housing is manufactured of powder coated metal and has a stainless steel top and inside surfaces 1 The cooler is installed on four caster wheels with brakes 14 15 The top of the keg cooler has metal railings 6 disoensing tower 12 and a drip tray 13 for spilled beer A cool beer keg is placed into the keg cooler 3 A coupler 4 is put into the keg The coupler ha
9. n Output Wi 17 Note A minimum clearance of 3 on each side and rear of cabinets required for optimum performance Note All specifications subject to change without notice 3 Keg cooler accessories refrigerator 1 drip tray 1 dispensing tower 1 optional owner s manual 1 packaging 1 4 Manufacturer s warranty UBC Cool warrants to the original end user of this product that should it prove defective due to improper workmanship and of material under normal use for a period of one year from the date of installation UBC Cool will repair or replace at its option any defective part without charge for the part Replacement parts are warranted for the remainder of the original warranty period The warranty does not include labor of other cost incurred for servicing repairing removing installing shipping or handling of either defective or replacement parts or complete unit Such cost may be covered by a separate warranty provided by the installing contractor This warranty does not cover damages caused by a accident abuse negligence or misuse b operating the product in a corrosive atmosphere containing chlorine fluorine of any other damaging chemicals c modification alteration poor service practices d improper matching or application of the product or components e failure to provide proper maintenance and service to the product according to manu
10. s beer lines and a CO2 line 5 connected to it A CO2 cylinder with manifolds 9 and a reducer 10 is kept outside of the keg cooler 8 The CO2 line is drawn inside the keg cooler to get connected to the coupler trough a hole in the back of the unit The fan and heat exchanger are located in the refrigeration chamber 10 Temperature inside the keg cooler is set with a thermostat 2 The refrigeration units can be reached for service by removing the covers 11 Safety instructions WARNING Instructions pertaining to the risk of fire electric shock or injury to persons GROUNDING INSTRUCTIONS For your personal safety this appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This appliance is equipped with a power cord having equipment grounding conductor and grounding plug The plug must be plugged into an appropriate wall outlet that is installed and grounded in accordance with all existing local codes and ordinances Consult a qualified electrician or serviceman if the grounding instructions are not clearly understood or if doubt exists as to whether your electrical wall outlets are properly grounded The manufacturer is not responsible for possible damage caused by improper and unsafe usage of the keg cooler Set up instructions Unpack the keg cooler and place it in the selected location LOCA