1. damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 gt Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d 0 0 Trg tigrovcev 1 5220 Tolmin Slovenia e Longo programmable controller LPC 2 DL1 module SMARTFEH LIVING SYSTEMS Index Longo programmable controller LPC 2 DL1 module I DESCRIPTION mat 1 2 FEATURES nn da ra 2 OPERATION orar 3 A den
2. a to work simultaneously When select as DSI master device one DSI data channel is supported DSI To select DSI mode of module operation Device Tx Address DL1_1a_oAdd must be set to 255 and Device Tx Data DL1_1a_oDat must be set to 254 To send dim level to DSI device Device Tx Address DL1_1b_oAdd must be set to O and corresponding dim level 0 255 must be send to Device Tx Data DL1_1b_oDat To stop sending dim level to DSI O must be writen to Device Tx Address DL1_1b oAdd Other twelve Device Tx Address DL1_1x_oAdd and Device Tx Data DL1_1x_oDat parameters do not take effect when module is in DSI mode of operation DALI DALI mode of module operation is automatically selected when Device Tx Address DL1_1x_oAdd value is in range O to 254 and Device Tx Data DL1_1x_oDat value is in range 0 to 255 DALI address DL1 1x _oAdd structure DALI address is one byte long YAAAAAAS High bit Low bit DALI short address 0 63 OAAAAAAS DALI group address 0 15 100AAAAS DALI broadcast 11111111S DALI special commands 101CCCCS and 110CCCCS A significant address bit S selector bit S 0 direct arc power level following in data byte DL1_xa_oDat S 1 command following in data byte DL1_xa_oDat C significant address command bit Y short or group address broadcast Y 0 short address Y 1 group address or broadcast DALI data DL1_1x_oDat str
3. dede a 4 3 2 Variables memory linia Ni 4 4 INSTALLATION ostia ip 6 4 1 Connection SNE viii AA AAA A A 6 4 2 MOUNTING INSEMUCHIONS siennes 7 4 3 Module LAD SING revivir ie 8 5 TECHNICAL SPECIFICATIONS scnicri nationales 9 6 CHANGES is 10 INOTES ne E ai diet 11 3 ss o 3 e Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS 1 DESCRIPTION LPC 2 DL1 is a master and power supply DALI Digitally Addressable Lighting Interface or DSI Digital serial Interface module It can control up to 64 slave DALI devices Its main field of application is controlling electronic dimmable ballasts in lighting system Module is powered from internal BUS NOTE For proper system configuration and data allocation please refer to LPC Composer software help menu Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS 2 FEATURES Figure 1 LPC 2 DL1 module Table 1 Technical data Standard DALI DSI master and power supply Small dimensions and standard DIN EN50022 35 rail mounting connection up to 64 slave devices ss e Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS 3 OPERATION LPC 2 ED1 module can be used in different modes of functioning With the parameters commands various control of DALI or DSI devices can be achieved When module is set as DALI master device module is supporting up to eight DALI addresses and DALI dat
4. e 6 SMARTFEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 DL1 module Version 3 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si Longo programmable controller LPC 2 DL1 module SMARTFEH LIVING SYSTEMS Written by SMARTEH d 0 0 Copyright O 2012 SMARTEH d o o User Manual Document Version 003 July 1 2012 O Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized representative Warranty does not include
5. ess 0 255 0 255 DL1_1h_ Dat 8 Device Rx Data 0 255 0 255 Longo programmable controller LPC 2 DL1 module SMARTFEH LIVING SYSTEMS 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme K1 K2 CEA LPC 2 DL1 DALI DSI OUT ENFI Electronic ballast Table 2 OUT OUT 1 Digital serial output in reference to OUT 2 0 18 Pa Q VDC Digital serial output ao Reference Reference to 15 V D Table 3 K1 Internal BUS Data amp DC power supply Connection to I O module Table 4 K2 Internal BUS Data amp DC power supply Connection to I O module 1 Wires connected to the module must have cross sectional area at least 0 75 mm Minimum temperature rating of wire insulation must be 85 C i ss e Longo programmable controller LPC 2 DL1 module SMARTFEH LIVING SYSTEMS 4 2 Mounting instructions Figure 3 Housing dimensions Dimensions in millimeters A Mounting instructions All connections module attachments and assembling must be done while module is not connected to the main power supply 1 Switch OFF main power supply 2 Mount LPC 2 DL1 module to the provided place inside an electrical panel DIN EN50022 35 rail mounting 3 Mount other LPC 2 modules if required Mount each module to the DIN rail first then attach modules together through K1 and K2 connectors Connect dig
6. ital serial output wires according to the connection scheme in Figure 2 Switch ON main power supply Dismount in reverse order For mounting dismounting modules to from DIN rail a free space of at least one module must be left on the DIN rail NOTE LPC 2 main control module should be powered separately from other electrical appliance connected to LPC 2 system Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard e Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS 4 3 Module labeling Figure 5 Labels on housing Label 1 Label 2 LPC 2 DL1 P N 225DL109001001 S N DL1 S9 0900000003 D C 40 09 Label 1 description 1 LPC 2 DL1 is the full product name 2 P N 225DL1080001001 is the part number e 225 general code for LPC 2 product family e DL1 short product name 08001 sequence code e 08 year of code opening e 001 derivation code e 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 08 is the date code e 16 week and e 08 year of production Label 2 description 1 S N DL1 S9 0800000190 is the serial number e DL1 short product name S9 user code test procedure e g Smarteh person xxx 0800000190 year and current stack code e 08 year last two cyphers e 00000190 current stack number previous module would ha
7. t 2 Device Tx Data 0 255 0 255 DL1_1c_oAdd 3 Device Tx Address 0 255 0 255 DL1_1c_oDat 3 Device Tx Data 0 255 0 255 DL1_1d_oAdd 4 Device Tx Address 0 255 0 255 DL1_1d_oDat 4 Device Tx Data 0 255 0 255 DL1_ 1e oAdd 5 Device Tx Address 0 255 0 255 DL1_ 1e oDat 5 Device Tx Data 0 255 0 255 DL1_1f oAdd 6 Device Tx Address 0 255 0 255 DL1_1f oDat 6 Device Tx Data 0 255 0 255 DL1_1g_oAdd 7 Device Tx Address 0 255 0 255 DL1_1g_oDat 7 Device Tx Data 0 255 0 255 DL1_1h_oAdd 8 Device TxAddress 0 255 0 255 DL1_1h_oDat 8 Device Tx Data 0 255 0 255 ss 3 Longo programmable controller LPC 2 DL1 module g SMART EH LIVING SYSTEMS Table 3 Values Memory Variable description Range Values DL1_1a_iAdd 1 Device Rx Address 0 255 0 255 DL1_1a_iDat 1 Device Rx Data 0 255 0 255 DL1_1b_ Add 2 Device Rx Address 0 255 0 255 DL1_1b iDat 2 Device Rx Data 0 255 0 255 DL1_1c_iAdd 3 Device Rx Address 0 255 0 255 DL1_1c_iDat 3 Device Rx Data 0 255 0 255 DL1_1d_ Add 4 Device Rx Address 0 255 0 255 DL1_1d Dat 4 Device Rx Data 0 255 0 255 DL1_ 1e Add 5 Device Rx Address 0 255 0 255 DL1_ 1e Dat 5 Device Rx Data 0 255 0 255 DL1_1f Add 6 Device Rx Address 0 255 0 255 DL1_1f Dat 6 Device Rx Data 0 255 0 255 DL1_1g_iAdd 7 Device Rx Address 0 255 0 255 DL1_1g_iDat 7 Device Rx Data 0 255 0 255 DL1_1h_iAdd 8 Device Rx Addr
8. ter can be status or command or both When parameter is marked as status this means that module is sending information to controller On the other hand command represents request from MCU to module Device Tx address parameter DSI or DALI selection and DALI address data parameter When 255 is written to this parameter DL1_1a_oAdd DSI is selected When 0 254 is written to this parameter DALI address command is sent to DALI device When some DALI channels 1 8 are not used write 255 to corresponding parameters DL1_1a_oAdd DL1_1h_oAdd Device Tx data parameter DSI selection and DALI data parameter When 254 is written to DL1_1a_oDat and 255 is written to DL1 1a oAdd parameters DSI is selected In DALI mode data command for corresponding DALI channel should be written to this parameter When some DALI channels 1 8 are not used write 255 to corresponding parameters DL1_1a_oDat DL1_1h_ oDat Device Rx address value Corresponding DALI device address is echoed to DL1_1x_iAdd value Device Rx data value Corresponding answer from DALI device can be read from DL1_1x_iDat value 3 2 Variables memory list Table 2 Parameters Memory Variable description Range Values DL1_1a_oAdd 1 Device Tx Address 0 255 0 255 DL1_la_oDat 1 Device Tx Data 0 255 0 255 DL1_1b_oAdd 2 Device Tx Address 0 255 0 255 DL1_1b oDa
9. ucture DALI data command is one byte long XXXXXXXX High bit Low bit For example when writing 2 00000010 to DL1_1a_oAdd and 127 01111111 to DL1_1a_oDat light with DALI ballast with short address 1 will lit with 15 127 of relative lighting level When writing 3 00000011 to DL1_1a_oAdd and 127 00000000 to DL1 1a oDat DALI command will be sent and DALI device with short address 1 will switch off Up to eight different DALI address and data parameters can be written to the module at the same time Corresponding answer from DALI device can be read from DL1_1x_iDat value and corresponding DALI device address is echoed to DL1 1x _iAdd value When one or more of DALI addresses and commands channels are not used DL1_1x_oAdd and Device Tx Data DL1_1x_oDat parameters for unused channel must be set to 255 For detail description of DSI Digital Serial Interface please refer to DSI documentation For detail description of DALI Digitally Addressable Lighting Interface please refer to IEC929 Annex E or other documentation Functions and possibilities will be described within parameters description SMARTTEH LIVING SYSTEMS Longo programmable controller LPC 2 DL1 module 3 1 Parameters If parameter is set to logical 1 is considered to be active enabled or set If parameter has logical value 0 is considered to be inactive disabled or cleared Parame
10. ve the stack number 00000189 and the next one 00000191 00 3 Longo programmable controller LPC 2 DL1 module g SMART EH LIVING SYSTEMS 5 TECHNICAL SPECIFICATIONS Table 5 Technical specifications Power supply from internal BUS Power consumption 2 W Number of standard DSI or DALI outputs 1 Connection type screw type connector for stranded wire 0 75 to 2 5 mm Dimensions L x W x H 90 x 18 x 60 mm Weight 509 Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position vertical es ae 20 to 60 C Pollution degree 2 Overvoltage category Electrical equipment Class II double insulation Protection class IP 30 ss 3 Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS 6 CHANGES The following table describes all the changes to the document Date v Description 1 7 2012 003 CGP General update 10 20 2011 002 Updated version and 3 Operation chapter added 29 2 2009 001 The initial version issued as LPC 2 DL1 module UserManual 10 Longo programmable controller LPC 2 DL1 module SMARSFEH LIVING SYSTEMS 7 NOTES