1. The screen clears after a few seconds 4 or 6 digit code For total set arming the keypad s left light indicator is on during the exit delay For part set arming the keypad s right light indicator is flashing during the entire ay set period DISARMING USING YOUR CODE OR TAG To enable you to get to the keypad without triggering an alarm your installer has programmed an entry delay of 30 seconds Depends on site configuration Se Enter a valid code or present a programmed TAG I oe v The disarming tone is emitted by the keypad and by the panel siren i 2 if set up p 4 or 6 digit code Disarming the system will also stop the sirens if an alarm is triggered Stopping the siren does not interrupt the transmission of the alarm to the ARC Note Depending on the configuration of your keypad this will disarm the total set or the entire system In the latter case the annex set might need to be re armed The system may include 0 to 4 keypads of this type DURESS GODE Ai A duress code can be used if you are forced to disarm your security system under duress Your duress code is 1 to your code 1234 gt 1235 6789 gt 6780 The 2 2 system will disarm as normal however a silent alert signal is transmitted to your Alarm Receiving Centre Code 1 INCORRECT CODE PROTECTION ne If you enter five successive incorrect codes or present five incorrect
2. TAGs the keypad is blocked for 5 minutes SENDING A PANIC SIGNAL even when your system is not armed Press the SOS keys simultaneously v The siren is triggered depending on configuration v The Alarm Receiving Centre is alerted KEYPAD DISPLAY lla Your keypad is equipped with a display to ease access to advanced user functions and rich content Menu functions are only accessible when the system is disarmed The display icons provide a quick view of the system status Unread message Total set armed Part set armed Detector activated Annex set armed Tamper fault System fault p A A Bypassed detector x x H 0 System disarmed Annex set disarmed Receiver 1 ON Receiver 2 ON Radio transmission in progress Blinking replace battery Silent mode Power supply fault se DI State of keypad battery The navigation keys are used to access the menu e Press the arrow keys Gp to enter the main menu navigate and view choices identified by brackets lt gt e Press the key to confirm your choice e Press the Return key to abort your choice and return to the main menu STATUS SCREEN llll ine When the keypad is turned off you can view the current status of the system by pressing OK This will display icons and fault messages if any SETTINGS MENU When the system is disarmed you can access the menu to modify the various se
3. on the keypad will confirm entry To change or set additional key tags e Select and enter an existing or new single digit user ID 0 9 User 1 is always the master e Present the new key TAG YA double beep on the keypad will confirm that the new TAG is programmed and replace the previous TAG if any 10 To adjust beep level e Press the total set arming key e Press the 8 key e Enter beep level from 1 to 7 v A double beep on the keypad will confirm the change To exit programming e Press the off key WARNING The system will automatically exit programming mode after 15 seconds if no keys have been pressed and the red light will turn off If this occurs you must restart this process from the beginning Total set arming CODE or TAG Part set arming CODE or TAG Disarming under duress Enter DURESS CODE CODE 1 Alert ee ae Enter programming O MASTER CODE OR MASTER TAG Change user code User ID 0 enter new CODE enter new CODE again Change user TAG User ID 0 9 present new TAG Change beep level enter beep level 1 7 11 6 How to use the keyfob with 1 LED ARMING Press the Total or Partial arm button v The indicator light on the keyfob comes on briefly when you release the button PS v The arming tone is emitted by the panel siren Total set arming If a door or window equipped with contacts is left open the system cannot be armed t Always make sure that y
4. Domonial User manual Manuel d utilisation Manual de uso Manuale dell utente Benutzerhandbuch Gebruikershandleiding Honeywell EKZ008200B 10 2007 Hi yw Il 2007 Honeywell International Inc iI il one e Congratulations on your purchase of the Honeywell Domonial security system To make the best out of your system we advise you to read this manual carefully This security system is designed to operate on an authorised radio frequency and will in no way endanger the user 1 INTRODUCTION TO THE SECURITY SYSTEM 2 2 INDICATOR LIGHTS 3 3 UNDERSTANDING THE SYSTEM TONES n 4 4 HOW TO USE THE WIRELESS KEYPAD WITH DISPLAY 5 5 HOW TO USE THE WIRELESS KEYPAD WITH PROX READER 9 6 HOW TO USE THE KEYFOB WITH 1 LED oo cesses 12 7 HOW TO USE THE KEYFOB WITH 3 LEDS eee 13 8 HOW TO CONTROL YOUR SYSTEM OVER THE PHONE 15 1 Introduction to the security system The Domonial control panel communicator unit is the brain of your security system It exchanges information with the associated wireless peripherals The control panel centralises the data sent by the detectors records the arming and disarming operations and communicates with the Alarm Receiving Centre The control panel also includes a speaker for alarm signalling and audio verification Your security system may allow up to 3 sets total
5. HING A fault on the system Battery Supervision Tamper Phone line failure or Radio jamming The indicator remains ON or FLASHING until the condition has been cleared Oz m 09 3 Understanding the system tones SIRENS ci A siren is an effective deterrent due to its power and very irritating tone The system has a siren built in the control panel An optional remote siren can be added In addition the panel built in siren emits an audible confirmation tone when arming and disarming the security system and a fire tone when a smoke detector is triggered The volume levels can be adjusted by the installer SYSTEM TONES i E i Sequence of 3 modulated sounds when arming total set confirms that the TOTAL SET i OTT control panel has received a valid code or ARMING Duration 4 seconds TAG and is preparing to arm total set PART SET Sequence of 2 modulated sounds When arming the part set confirms that ARMING p AAPA the control panel has received a valid ANNEX SET code or TAG and is preparing to arm part ARMING Duration 2 5 seconds set Upon arming Beeps sound at the end of the exit time EXIT DELAY OH al until the system is armed One beep per second Upon entry After you open the entry door the entry time starts You should disarm your ENTR DETAY F d system within this time B
6. INTENANCE 5 SEARCHING TCU NO YES OTHER FUNG TIONS iiiiiia sees ara EEEN E You can deactivate the beeps played on the panel s built in siren by selecting the T SILENT MODE G You can also activate the chime which may be associated to some of the detectors in your installation by accessing the CHIME menu JE Home automation functions are in a dedicated menu REMOTE PLUGS Select the electrical device and turn it on or off On some systems it is possible to trigger the camera on detectors equipped with one 09 BATTERY REPLACEMENT l l l l l l lllll in WARNING H Ro ae There is a risk of explosion The battery indicator O on the keypad display indicates when to replace in case of incorrect the battery Open the battery cover on the back of the keypad and insert a replacementof the battery CR123A 3V battery respecting the polarities Replace only mihi e Dewey ry p 9 p of the same type or an equivalent type which has been recommended by the manufacturer CG This function requires an optional X10 extension with X10 modules 5 How to use the wireless keypad with prox reader The keypad is used to arm and disarm your security system using a valid access code or key TAG To use all his functions you must have the master code chosen during the installation or have the master key TAG ARMING USING YOUR CODE OR TAG Press an arming key on th
7. ct only a part of your premises whilst you are in the other part This function requires an optional X10 extension with X10 modules 12 6 How to use the keyfob with 3 LEDs ARMING i Press the total or part set arming button v The associated LED blinks during communication with the panel and remains lit for 3 seconds to confirm the system is armed If a door or window equipped with contacts is left open the system cannot be armed v The disarm LED lights continuously Total set arming e Close all doors and windows then try again v The arming tone is emitted by the panel siren Part set arming Note that with this keyfob arming is immediate Only arm the system once you are outside the premises DISARMING seierrike EEEN TEAREN L aio Press the disarming button v The associated LED blinks during the communication with the panel and then lights for 3 seconds to confirm the instruction Disarming v The disarming tone is emitted by the panel siren Disarming will also stop the siren but it does not interrupt the transmission to the ARC station ARMING AND DISARMING THE ANNEX SET If the system is configured for annex arming e To arm Press the Total and Control buttons simultaneously Total Contr l e To disarm Press the Disarm and Control buttons simultaneously GJ Disarming Contr l PERSONAL ATTACK R E G En You can send an instant panic alarm if you feel threatened whilst a
8. e keypad Enter a valid code or present a programmed TAG v A flashing red light on the keypad confirms that the code is valid Teles arming v The arming tone is emitted by the panel siren followed by the exit delay beeps If the system diagnoses a fault on arming the arming tone is followed by a tone indicating a fault ant got arming v Arming is automatically completed at the end of the delay Depends on site configuration 7S Py Always make sure that your arming request is followed by the arming tone TAG 4 or P i 6 digit code If a perimeter fault is signalled on arming please disarm the system before verifying doors and windows equipped with contacts 5 na ha ee DISARMING USING YOUR CODE OR TAG ll ll To enable you to get to the keypad without triggering an alarm your installer has programmed an entry delay of 30 seconds Depends on site configuration SD eS Enter a valid code or present a programmed TAG Y v A green light on the keypad confirms that the code is valid i v The disarming tone is emitted by the panel siren 000 000 Disarming the system will also stop the sirens if an alarm is triggered Stopping 000 the siren does not interrupt the transmission of the alarm to the ARC Note Depending on your keypad s configuration this will disarm the total set or the entire system In the latter case the annex set might need to be re armed The system may include 0 to 4 k
9. eeps sound at One beep every second the end of the entry time COINS beep When Disarming confirms that the DISARMING Om control panel has been successfully Duration 2 5 seconds disarmed 2 times 7 fast beeps FAULT This tone indicates a fault in the system Pope 4 beeps in case of alert ALERT Confirms the transmission of an alert to SSS the Alarm Receiving Centre sent via the keypad 4 How to use the wireless keypad with display The wireless keypad with display offers a complete range of tools to manage your alarm system from normal operation to dedicated user functions The keypad is used to arm and disarm your security system using a valid access code or key TAG The master code or TAG is required to modify other users codes and TAGs ARMING USING YOUR CODE OR TAG If the keypad is not in its base please return it there for Total or Annex set only Press an arming key on the keypad If the system diagnoses a fault on arming a fault message is displayed Press the Total set arming OK key or the arming key to bypass the faults and continue the arming process Enter a valid code or present a programmed TAG Part set arming v The arming tone is emitted by the keypad and by the panel siren if setup v The screen counts down the exit time remaining v Arming is automatically completed at the end of the delay Depends on site configuration The icon confirms the completion of setting
10. eypads of this type On some keypad models presenting the TAG more than 2 seconds will arm the system without pressing the Arm key 9 DURESS CODE a A duress code can be used if you are forced to disarm your security system Code 1 under duress Your duress code is 1 to your code 1234 gt 1235 6789 gt 00 6780 The system will disarm as normal however a silent alert signal is transmitted to 000 your Alarm Receiving Centre INCORRECT CODE PROTECTION in If you enter 5 successive wrong codes the keypad is blocked for 5 minutes PERSONAL ATTACK uao ei You can send an instant personal attack alarm whenever you feel threatened whilst at home even when your system is not armed Press the SOS keys simultaneously v The siren is triggered depending on configuration v The Alarm Receiving Centre is alerted SOS PROGRAMMING YOUR KEYPAD The keypad can have up to 10 users User 1 has the master code or master TAG To enter programming e Press on and off control keys simultaneously Li v The red light will flash slowly e Enter the master code or present the master TAG To change or set additional user codes e Select and enter an existing or new single digit user ID 0 9 e Enter the new code for this user v A double beep on the keypad will confirm entry e Enter the new code again to confirm it v A double beep
11. nd v All the LEDs light several times in succession and then the LED for the current arming status remains lit for 3 seconds CHANGING THE BATTERY ce There is a risk of v When the battery starts to run down instead of remaining fixed explosion if the correct the LEDs will fade out gradually battery is not used 9 P j g Replace only with v Insert a small screwdriver into the space in the back of the casing battery type CR2032 as shown in the illustration Push with the screwdriver whilst levering Panasonic or GP upwards and the front of the casing will release v Use the screwdriver to push the old battery gently out of its housing and slide the new battery into place v To close the casing insert the lower part of the front into the rear casing then slide the upper portion into place and press firmly until it clicks Depending on your needs your installer will advise you on the different options for controlling equipment This function requires an optional X10 extension with X10 modules 7 How to control your system over the phone Control of your system over the phone is only possible from a multi frequency phone tone dialling or from your cellular phone This function must be configured by the installer The Domonial control panel picks up your call after the number of rings configured by the installer or after it has been called twice successively To access your system e Dial the ph
12. o monitoring of the system peripherals Electrical Transmission e Mains supply with battery backup e Built in telephone transmission e Built in voltage surge protection e Telephone line loss detection e System supply monitoring e Transmission monitoring by periodical tests e Optional GSM transmitter 2 Indicator lights The front cover of the control panel features LED indicators which show the status of your security system f A Bx es 1 LED INDICATOR AC MAINS POWER oon ee eseseesesesseseeseesestensarsecarencersesereneeneseey 4 ON The Control Panel is supplied from the Mains OFF There is a mains power failure The control panel is supplied by its built in battery 2 LED INDICATOR SYSTEM ARMED A ON The system total set is armed OFF The system is disarmed FLASHING The system part or annex set is armed 3 LED INDICATOR DETECTOR ACTIVATED ooo eeesessececseesestenesecseencaneneeeeereneane T FLASHING One of the window or door protected by a magnetic contact is opened It flashes until the window or door has been closed 4 LED INDICATOR ALARM MEMORY iii TX ON An intruder alarm occurred while the system was armed FLASHING An alarm occurred while the part set or annex set was armed The indicator remains ON until the next arming 5 LED INDICATOR TECHNICAL FAULT gt gt ON A fault on a technical channel FLAS
13. one number of your security system v A 2 second beep sounds followed by the Arpeggio invitation tune e Enter a valid code within 30 seconds v A high pitch beep confirms that the code is valid To arm your system e Dial 21 to arm the total set 22 to arm the part set 23 to arm the annex set v Arming is confirmed as soon as you can hear a melody To disarm your system e Dial 31 to disarm the total set 32 to disarm the part set 33 to disarm the annex set To control an electrical device e Dial 101 to 112 based on the number of the equipment programmed in your alarm system v One short beep informs you that your equipment is active v Two beeps inform you that your equipment is not active e Dial 1 to turn on the device 0 to turn it off To listen to the site and talk through the microphone of the control panel if configured e Dial 6 to enter listening in mode You can immediately listen in to your house e Dial 1 to talk and 0 to listen again To terminate the call e Dial then v Your security system ends the call Access your system Call system Enter CODE Total set arming 21 Part set arming 22 Annex set arming 23 Control equipment 101 112 1 ON 0 OFF Audio verification 6 1 TALK 0 LISTEN Terminate the call This function is not available on all product versions and depends on country regulations This function requires an optional X10 exten
14. our arming request is followed by the tone Partial set arming DISARMING To disarm press the disarm button Lo v The indicator light comes on briefly when you release the button g k Disarming v The disarming tone is emitted by the panel siren Disarming will also stop the siren but it does not interrupt the transmission to the Alarm Receiving Centre CALLING FOR ASSISTANCE PERSONAL ATTACK These buttons enable you to call for assistance at any time Press the SOS buttons simultaneously ra ra v The indicator light on the keyfob comes on briefly when you release the button v The siren is triggered depending on the configuration v The Alarm Receiving Centre is alerted The personal assistance function can be used even when your system is not armed f this has been set up by the installer the siren stops automatically after 30 seconds but you can stop it manually by pressing the disarm button SPEGIAL BUTTON ie ea ea ii The action of the special button is dependent on your configuration As an assistance button it enables you to call for assistance In this case press the button pause until the indicator light comes on then press again As a remote control for electrical appliances press the button to turn each appliance on and off successively The system can include 0 4 keyfobs of this type Provided that this function has been programmed by the installer you can choose to prote
15. set part set annex set It may include e A KEYPAD WITH DISPLAY for arming and disarming operations and access to advanced user functions like detector bypass and events log e A KEYPAD WITH PROX READER for all users arming and disarming operations of the different sets e A KEYFOB associated to one or more users for arming and disarming operations e A PIR DETECTOR is a motion detector which reacts to the temperature fluctuations caused by a person in motion e A DOOR CONTACT is a magnetic contact which two parts are fitted one on a door frame and the other on the door itself When the door or window is open the detector is triggered Before leaving the premises always make sure that all openings are properly closed e A GLASS BREAK DETECTOR which analyses the various frequencies emitted by glass being broken e A SMOKE DETECTOR mounted on the ceiling which ensures the coverage of about 50 square metres Refrain from smoking in the vicinity of this detector e A SHOCK DETECTOR mounted on the window door frame which detects the vibrations emitted when a door window is opened or closed Radio Operational e Narrow band frequency modulation e Up to 3 protected sets Total set Part set Annex set e Identification code for each component e Up to 30 detectors no interference between neighbouring systems e Alert functions e Protection against attempted jamming e All components protected against tampering e Radi
16. sion with X10 modules 15 E mr O Z 8 Maintenance and recommendations Check your system regularly once a month or follow your operator s specifications Do not try to open or move the components They are tamper protected and some of them can cause electric shocks Except for the optional external siren the components of your system are suitable for indoor use only Keep them in a clean dry place at ambient temperature Avoid shocks for all the components and especially avoid dropping the keyfob Do not immerse in water Use a dry rag only no detergent to clean the components Dispose of old batteries in containers for this purpose Avoid exposure to prolonged siren emission Do not hide motion detectors behind curtains furniture etc Do not paint or paper over the components 16
17. t home even when your system is not armed Press the SOS buttons buttons 2 and 4 simultaneously 4 a v Depending on the configuration the siren may be triggered v The ARC is alerted The system can include 0 4 keyfobs of this type Provided that this function has been programmed by the installer you can choose to protect only a part of your premises whilst you are in the other part 13 DISARMING AFTER AN ALARM i If there is an alarm in your absence When you press the disarm button all three LEDs blink slowly v The system will not disarm in order to avoid beeps that could attract the attention of an intruder To confirm disarming press the disarm button again v The associated light blinks rapidly during communication with the panel then lights for 3 seconds to confirm disarming REMOTE CONTROL OF APPLIANCES EQUIPMENT i If this has been configured by the installer you can control up to 4 household appliances lights etc However the default is 2 The Control button controls the first appliance v The 3 LEDs blink until the command is registered at the system then remain lit for 3 seconds The Control button and the Partial Arm buttons control the next three appliances J respectively v LEDs 1 and 2 blink until the command is registered at the system then remain lit for 3 seconds CHECKING THE STATUS OF YOUR SYSTEM Press the control button for one seco
18. ttings of your system e The system can have up to 10 users User 1 has the master code or master TAG and is the only user authorised to modify all users CODES and TAGS All codes should be different from one another and from other duress codes 1 to existing codes e It is possible to simplify the arming operation by changing ARM WITH CODE so the system arms without a code or a TAG You can bypass a detector for one set period if you need to leave a room without protection by accessing the MANUAL BYPASS menu and selecting a detector You can customize the arrow keys on your keypad for direct access to functions in the menu by modifying SHORTCUTS TIME AND DATE can be updated by the user on some systems EVENT MENU You can view EVENTS recorded by the system on your keypad screen TEST MENU uui ii To verify the performance of your system you can test SIRENS and LIGHTS You can also initiate a search for mobile keypads out of their base by accessing SEARCHING TCU If your system requires maintenance your alarm company can request remote access to your system enter MAINTENANCE mode to authorize the remote maintenance 1 ANNEX 2 SILENT MODE 3 CHIME 4 MAIL 5 EVENTS 6 SETTINGS 7 TESTS 8 REMOTE PLUGS CODES TAGS MANUAL BYPASS ARM WITH CODE DATE AND TIME SHORTCUTS LANGUAGES NONANI TESTS 1 SIRENS 2 LIGHTS 3 TRANSMISSION 4 MA