E Instruments AQ 200 Manual

image

Contents

1. gt to enter into sub function Manual dataset b Select Manual with A and V Confirm wih OK c Select Name with A and V Confirm wih OK or Dr Enter dataset name with arrow keys lt q gt and V Confirm wih OK d For measurement launching click on OK with the access key The number of points selected and the parameter are displayed e To save your dataset click on Save with the access key actoolsupply com actoolsupply com IV Menus 1 2 Automatic dataset Auto dataset An automatic dataset is composed of measuring points with interval of time a Click on OK or to enter sub function b Select Auto with A and V Confirm wih OK c Select Name with A and V Confirm wih OK or Enter dataset name with the arrow keys gt and A V Confirm wih OK d Enter dataset time and interval of time between 2 measurements by selecting Period with access key Select Duration or Interval with A and V Confirm wih OK Enter minutes and seconds with arrow keys and V from 1 minute to 24 hours for the duration and from 5 seconds to 10 minutes for the interval Confirm with OK e Select Start for dataset launching C TOOL PLY COM 207 1244 2 Launch a planned dataset A planned dataset is composed of several locations For each location the operator can enter a theorical value and a tolerance for the parameter to be controlled Planification must be made via the software a Click on OK or gt
2. to enter into sub function b Select Planned with A and V Confirm wih OK c Choose dataset name with A and V Confirm wih OK d Select the location with A and W Confirm wih OK 3 Preview of tables of points of datasets Dataset summary You can display tables of points of datasets performed on the device a Go to Recording menu b Select Display Click on OK to validate c Select dataset name with arrow keys A et V Click on OK to validate Summary screen of selected dataset is displayed From this screen you can e Select other dataset using arrow keys lt and gt e Display data of other channels using arrow keys A and V d Click on Mesure to display values table of selected dataset Dataset table From this screen you can us ERIT ERC Browse values table of points of the same channel pressing Prev or Next e Change of channel with arrow keys lt and P Back to dataset summary screen pressing Visu 4 Delete all datasets Select Delete with A and V Confirm wih OK actoolsupply com actoolsupply com IV Menus oO C TOOL OM PLY C 207 1244 arameters Se e Language Click on OK or gt to enter and a list of languages available appears Select language with arrow keys A and W and Confirm wih OK e Date time Click on OK or gt to enter into sub function Enter the day with A and W then move to the next digit with Kk Repeat this operatio
3. instruments to guarantee a constant level of quality of your measurements In regards of Quality insurance norms we recommend that the instruments are checked once a year Warranty KIMO Instruments have 1 year guarantee for any manufacturing defect return to our After Sales Service required for appraisal C TOOL PLY COM 207 1244 en P Distributed by actoolsupply com
4. to 80 C 0 4 of reading 0 3 C 0 1 C Air pressure hPa from 800 to 1 100 hPa 3 hPa 1 hPa CO I Temperature i DER eC F from 20 to 80 C 0 4 of reading 0 3 C 0490 CO ppm from 0 to 100 ppm 5 ppm 1 ppm from 101 to 1 000 ppm 3 of reading 5ppm CO Temperature Temp CF from 20 to 80 C 0 4 of reading 0 3 C 01 C M CO ppm from 0 to 5 000 ppm 3 of reading 50 ppm 1 ppm CO Temperature Hygrometry Temp Leo from 20 to 80 C 0 4 of reading 0 3 C 0 1 C MC 00 from 0 to 5 000 ppm 3 of reading 50 ppm 1 ppm Hygro from 5 to 95 RH See Climatic conditions module 0 1 RH Pt100 Smart plus or wireless probes See related datasheet Ke from 50 to 250 C gt lt 0 3 of reading 0 25 C According to model According to model 0 01 C All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with required compensation As per NFX 15 113 and the Charter 2000 2001 HYGROMETERS GAL Guaranteed Accuracy Limit which has been calculated fe a coverage 5 value of 2 is 2 88 RH between 18 and 28 C on the measuring range from 5 to 9596 RH Sensor drift is less than 196 RH year The accuracy is expressed either by a deviation in C or by a percentage of the value concerned Only Cl t i CtOOISUDDpIy com actoolsupply com Il Introduc
5. LY COM actoolsupply com 207 1244 _ aikencolon com sihi TOOL P Air Quality E Instruments AQ200CO IAQ E Instruments AQ200P IAQ gt o ZE actoolsupply com actoolsupply com Table of contents Feat 4 Technical features ARMEN a D DOECITICARIQNS aan ananas aan aan na ana 4 Il Ti gv elef del 5 SCIE D Nell d H 6 IE Cie SVEN 7 Using wire probes and modules nn 8 Use wireless e 8 Pod NAME 8 Bret eC E 9 Thermocouple Te ost H Klee Ui e DEE H SITE CT 11 E e le ee ee a c 11 D te ein 11 IIe Le e lee eec ai 11 tere 11 Downloading data ME 11 V General information NEEN 12 On 12 Maintenance EE 12 el CY E 12 C TOOL PLY COM 207 1244 uk alkencolon com actoolsupply com actoolsupply com Technical specifications O Technical features Sensing elements DIS DIAY M Graphic display 128x128 pixels Dim 50 x 54 mm blue blacklit Display of 6 Air quality probe measurements including 4 simultaneously CO NDIR infrared sensor Non dispersive infrared Housing IP54 ABS shock proof CO Electrochemical sensor Keypad Metal coated 5 keys 1 joystick Temperature Pt100 class A Conformit Elect tical tibilit Hyg
6. eless probe with arrows keys A and W and confirm with OK Functions The following functions are enabled only if at least one probe is connected You can access to the following sub functions Hold Min Max Configuration Delta T Parameters Calculation Recording Measurement display Press 1x in order to select HOLD function measurement holding on display SS Press 2x in order to select Min Max function display of minimum and maximum values Press 3x back to the continuous measurement PLY C OM 207 1244 actoolsupply com actoolsupply com IV Menus o Configuration A If you use thermocouple probes you must enter type into the Configuration sub function C TOOL Configuration sub function allows to e Select thermocouple PLY COM Click on OK or to enter into sub function a list of thermocouple available K J or T type appears 207 1244 Select type with A and W Confirm with OK eer e Select display Click on OK or gt to enter into sub function Select channel required with arrow keys A and W and confirm with OK Select respectively ON or OFF with A and W inorder to enable or disable this function Confirm with OK e Select units Click on OK or to enter into sub function a list of units available appears For each channel select unit required with A and V Confirm with OK Click on Esc to return to previous
7. n for the month year hour and minute Confirm wih OK e Beep This sub function allows to enable or disable the keypad beep Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and V inorder to enable or disable the beep Confirm wih OK e Extinction This sub function allows to enable the automatic shut off and to select the delay in minute Click on OK or gt to enter into the sub function Select with A and V OFF in order to disable the automatic shut off or enter the delay from 15 to 120 minutes Confirm wih OK e RF logging This sub function allows to enable or disable the RF logging Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and V inorder to enable or disable this function Confirm wih OK Downloading data see DataLogger 10 user manual chapter Ill Read device page 6 actoolsupply com actoolsupply com V General information Info menu This menu allows to view the serial number of instrument and firmware version Battery When battery indicator flashes it is recommended to change the batteries 1 Remove the front part at the back of the instrument 2 Remove batteries 3 Insert new batteries AA LR6 1 5V in accordance with proprer polarity drew inside the housing 4 Replace the front Maintenance KIMO performs calibration adjustment and maintenance of all your
8. nication z Wireless probes shall be located near the instrument for initial recognition Connection between AQ200 and wireless probes must be established See submenu Wireless probes p 8 actoolsupply com actoolsupply com Ill Browsing d Power up Enter code 0000 Homepage display ios ee Se Frans Y Probe connection Probes display TED Cm Measurement Measurement display Return to previous screen ym Probe Config eent gh COM Dor TR gt aikencolo Enter key code with directional pad if the locking is activated b ad A V Select a sub menu with access keys or with arrow keys lt gt Select a connection with right and left keys lt gt Connections can be activated or deactivated with A or V Select a sub menu with access keys or with arrow keys lt gt Select a sub menu with access keys or with arrow keys lt gt Communication interrupted Check probes connection actoolsupply com actoolsupply com IV Menus Probe menu 1 Using wire probes and modules Wire probes and modules with Smart plus system are automatically recognized from first connection The Probe menu only appears when probes or module are connected This menu allows to view probe information plugged to C2 Module C1
9. or wireless connections See Connections p 6 for more information about connections Probe display Available information are e Sensor type Serial number Date of last calibration or adjustement Probes Status enabled ou disabled On enabled mode the probe is connected the measurement is carried out and the value is displayed Infos 4 Measure 4 Params On disabled mode the probe is connected the measurement is not carried out and the value is not displayed RF probes display 2 Using wireless communication A Add a wireless probe A1 Go to probe menu by pressing Probe access key A2 With arrow keys and gt goto RF probes display A3 Select with access key RE probestecarchind A4 Power up the probe and press multifunction button until LED blinks Once the probe is recognized information appears Left button allows to return to the wireless probes display and to access all wireless probes already recognized by the instrument With access keys it is possible to delete E a wireless probe RF probes detected B Select a wireless probe already created B1 Power up the wireless probe short press on Multifunction button B2 Go to Probe menu B3 With arrows keys and gt goto RF probes display All the wireless probes already recognized appear B4 Select the suitable wireless probe with A or V B5 Go to probe informations using arrow key P B6 Enable the wir
10. rometry capacitive hygrometry sensor onformity ectromagnetical compatibility NF EN 61326 1 norm Climatic conditions module Power supply 4 alkaline batteries 1 5V LR6 Hygrometry capacitive hygrometry sensor Operating environment Neutral gas Temperature semiconductor temperature sensor Air pressure capacitive sensor Operating temperature from 0 to 50 C Storage temperature from 20 to 80 C Thermocouple probes type K J and T class 1 Auto sbutaft adjustable from 0 to 120 min Pt100 Smart plus probes Pt100 class 1 3 Din Weight 380g AQ200 connection see p 6 Languages English French Measuring units Measuring ranges Accuracy Resolutions CURRENT VOLTAGE V mA from 0 to 2 5 V 2mV 0 001 V from 0 to 10 V 10mV 0 01 V from 0 to 4 20 mA 0 01mA 0 01 mA THERMOCOUPLE See related datasheet G F K from 200 to 1300 C 1 1 C ou 0 4 Reading value 0 1 C T C J from 100 to 750 C 0 8 C ou 0 4 Reading value 0 1 C T from 200 to 400 C 0 5 C ou 0 4 Reading value 0 1 C CLIMATIC CONDITIONS Hygro RH from 5 to 95 RH Accuracy Repeatability linearity 0 1 RH hysteresis 1 8 RH from 15 C to 25 C Factory calibration uncertainty 0 88 RH Temperature dependence 0 04 x T 20 RH if T lt 15 C or T gt 25 C Temp C F from 20
11. screen Delta T When two PT100 probes or 2 thermocouple temperature probes are connected AQ200 can calculate Delta temperature value the temperature difference between C2 and C1 or T2 and T1 or T4 and T3 Select Delta T in order to view the temperature difference If you select Delta T again Delta T function is disabled Alarms Select respectively ON or OFF with A and W in order to enable or disable the alarm Choose your setpoint CO Limit 1 first CO setpoint CO Limit 2 second CO setpoint low temperature setpoint and high temperature setpoint Confirm with OK or gt Select thresholds with OK or to enter CO and temperature setpoints Select or signs with A and V then pass on the first digit with B Low and high thresholds entered confirm with OK Recording Select dataset The Recording menu allows a measurement dataset You can choose between a planned or a continuous dataset Memory capacity of the instrument is up to 8 000 points or 50 datasets 1 Create or launch a continuous dataset A continuous dataset can be carried out using AQ200 and is composed of several dated measuring points The Enter name operator can choose an automatic or a manual dataset with an instant value or an average This datasets can t be set using Datalogger 10 Software 1 1 Manual dataset A manual dataset is composed of measuring points selected by the operator a Click on OK or
12. tion C TOOL FA COM 207 1244 VEER v j AQ 200 actoolsupply com actoolsupply com Il Introduction Connections e Interchangeable measurement modules Interchangeable modules with Smart plus system are automatically recognized when connected to the instrument 1 Current voltage module 2 Thermocouple module It allows current or voltage measurements on V A1 or VA 2 It allows thermocouple temperature measurement on Tc1 channels with current voltage input cables or ammeter clamps Tc2 Tc3 and Tc4 channels with type K J or T with wire thermocouple probes equiped with a miniature male connector 3 Climatic conditions module It allows hygrometry measurement on Hygro channel ambient temperature measurement on Ptx channel and air pressure on PATM channel e Wire probes with Smart plus system Pt100 Temperature Wire probes with Smart plus system are automatically recognized when connected to the instrument Probes are connected on min DIN connectors C1 and or C2 Mini Din C2 Mini Din C1 connector connector Secured Mini Din Connector C TOOL o2 Wireless probe instrument communication PLY COM 207 1244 Wireless communication between probe and instrument with automatic recognition after power up _ aikencolon com e Pt100 probes are displayed on Tri or Tr2 channels followed by wireless commu