Home
DENVER_ASA-40_-_English
Contents
1. DENVER denver electronics com ASA 40 Pet Immune Wireless Motion Detector Cs Box Content 1 x PIR Pet Immune Motion Detector 1 x Bracket 1 x User Manual The ASA 40 is a high performance wireless pet immune PIR motion detector This motion detector will not trigger the alarm when your pets under 25kg move inside your home even if your alarm system is armed Before Using for the First Time Open the case and remove the battery activation strip to activate the batteries Self testing starts for 30 seconds Installation Fix the bracket on the wall with screws and attach the detector to the bracket Adjust the bracket to change the detection distance and angle It is recommended to mount the detector 2m from the ground Avoid mounting the detector close to windows air conditioner heater refrigerator oven sunshine and places where the temperature changes fast or where the air stream flows frequently If two detectors are installed in the same detection scope adjust the location to avoid interferences and false alarms The detector is more sensitive to cross movements than vertical movements TIOS Top view Side view petccuen scope Mode Setting Testing mode Once the self testing is complete long press the test button The sensor switches to testing mode and scans once every 10 seconds After 3 min utes the LED blinks twice and the sensor switches to working mode Working mode Stand by mode In wo
2. e submitted free of charge at recycling stations and other collection sites or be collected from the households Additional information is available at the technical department of your city Importer DENVER ELECTRONICS A S Stavneagervej 22 DK 8250 Egaa Denmark www facebook com denverelectronics Hereby Inter Sales A S declares that this product HAS 120 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC A copy of the Declaration of conformity may be obtained at Inter Sales A S Stavneagervej 22 DK 8250 Egaa Denmark
3. mper switch Infrared sensor Infrared sensor Detects the infrared rays released by human body motion Do not touch the surface Keep the surface clean Tamper switch When the alarm system is armed the tamper switch will trigger the alarm if the case is opened Jumpers for Zone setup The jumpers enable you to assign the detector to a specific zone Refer to the user manual of your alarm system for more information on zone set up Standards ALL RIGHTS RESERVED COPYRIGHT DENVER ELECTRONICS A S DENVER www denver electronics com CE pie Electric and electronic equipment and included batteries contains materials components and substances that can be hazardous to your health and the environment if the waste material discarded electric and electronic equipment and batteries is not handled correctly Electric and electronic equipment and batteries is marked with the crossed out trash can symbol seen below This symbol signifies that electric and electronic equipment and batteries should not be disposed of with other household waste but should be disposed of separately As the end user it is important that you submit your used batteries to the appropriate and designated facility In this manner you make sure that the batteries are recycled in accordance with legislature and will not harm the environment All cities have established collection points where electric and electronic equipment and batteries can either b
4. rking mode if the sensor is triggered more than twice within 3 minutes it will switch to standby mode to save power If no movement is detected within the next 3 minutes the sensor goes back to working mode Register the detector in the alarm system Switch to Connection Mode on the control panel Press the test button of the sensor twice The control panel beeps once the motion detector is registered If you hear two beeps the detector has already been Test connected _t Button To check if the registration is complete arm i the system and trigger the sensor again If the siren rings out the registration is successful Specifications Power Supply Housing material DC 3V AA 1 5V LR6 x2 ABS plastic Static current Operating conditions lt 90UA Temperature 10 C 55 C Relative Humidity lt 80 non con Transmitting current densing lt 9 5mA Detector dimensions Transmission distance 105 x 52 x35 mm lt 80 m in open area Bracket dimensions Radio frequency 52 x 30 x 26 5 mm 433MHz 75KHz LED indications Blinks continuously Self testing Blinks once An intruder is detected Blinks twice Self testing is complete entering working mode Blinks three times every 3 seconds Under voltage indication the batteries must be replaced the user will be informed by SMS when the batteries are low if the detector is registered in the control panel PCB Layout Jumpers for zone setup a Ta
Download Pdf Manuals
Related Search
DENVER_ASA 40_ _English
Related Contents
Avaya Configuring VRRP Services (308647-14.20 Rev 00) User's Manual User manual Adra Match Accounts 13 Builder`s Tools /Woodworking - General Tools And Instruments Philips 42PF9830 42" LCD HD Ready widescreen flat TV 42" Pearl - White Silver (11092) Montage-Betrieb_Mk5_DE_1115662 OMNILUX_HQI_90V_250W_R7s lamp user manual HP Server tc2110 Installation Guide Untitled Power management. Beautifully simple. Copyright © All rights reserved.
Failed to retrieve file