Home
instructions
Contents
1. B ON OFF Button l 2 C We recommend that the scale be calibrated before use This wo 4 Press the button to turn on the Gen 6 It will go into a 3 minute warm up cycle Once this is complete the scale will go to zero If desired the warm up cycle can be cancelled by pressing however for best result we recommend that the scale be warmed up before use To turn off the Gen 6 press and hold the ON OFFl button Always turn off the Gen 6 using the ON OFF button first and then unplug the power transformer Calibration should be done without the powder pan on the platform Press the CAL ZERO button to reset the scale to zero Press and hold the CAL ZERO button The LCD will display Cal 50 Place the 50 gram weight onto the platform and press the CAL ZERO button again Press and Release Do Not Hold The LCD will display 0 0 Remove the 50 gram weight The LCD will display 771 6gn or 50 00g Press CAL ZERO one more time to reset zero D l 2 Scale and Dispense Mode The scale and dispenser are now active Place the powder pan onto the platform and press the CAL ZERO button to zero the scale Place the desired smokeless powder black powder or Pyrodex should NEVER be used into the powder reservolr The scale will read in grains default unless changed To select the weighing unit desired press the MODE button to select the appropriate gr
2. Lyman Compact Touch Screen Powder System Visit us at www lymanproducts com 12 12 WARNINGS AND CAUTIONS Static charges can cause drift Like most electronic devices housed in plastic cases it is possible for the scale to pick up a static charge The Gen 6 is built with anti static material however in the unlikely event that a static charge 1s present the scale s display may move or drift in use To correct this condition we recommend wiping the scale down with a paper towel dampened with some window cleaner This should eliminate any static charge in the scale Many scales can be affected by strong electrical signals given off by items such as cell phones cordless phones microwaves etc While this scale has advanced circuitry which is shielded to prevent electronic interference from outside sources we would still recommend that these items not be used close by while the scale is in use When changing powder be sure that ALL powder is removed from the scale before new powder is added In particular carefully remove and check the powder feed tube and powder box for any remaining powder Powder will remain in the feed tube after the last charge is dropped See Cleaning the Gen 6 TM for disassembly instructions If the Gen 6 does not read zero on the display DO NOT DISPENSE POWDER The scale must be zeroed before use If powder is dispensed with a scale that does not read zero the charge wil
3. Then unscrew powder dispensing tube by turning in counter clockwise direction Be careful to catch any remaining powder that may still be in the tube Now with the powder chute closed press in the powder box from the back and release it The box will pop out slightly for easy removal and cleaning Before reassembly BE SURE all powder is removed from the feed tube and the powder box To reassemble the dispenser push the powder box back in until it clicks in slide the powder tube back through the bushings in the powder box and screw it to the motor shaft until finger tight Insert J shaped rod in small hole to assist in aligning the powder feed tube to the coupling threads See Figure B Snap the reservoir base back inside the powder box and lock in with the sliding latch Reinstall the reservoir tube Figure A Figure B Suggestions Tips 1 If exposed to a sudden change in temperature allow the Gen 6 30 minutes to stabilize to the new location before use 2 The removeable dust cover can be lifted off for ease of use If lowered into place during use however it will prevent any air drafts from affecting the accuracy of the scale We recommend storing the Gen 6 with the dust cover on and covering the platform as added protection to prevent anything from hitting the platform and damaging the load cell Gen 6 Load Sheet Cartridge Primer Powder Powder Bullet Comments Number Type Weight Lyman Products Corp 475 Smi
4. ains grams or ounces Key in the desired charge weight using the keypad If you make a mistake press the CAL ZERO button to clear the complete charge weight or press STOP CANCEL to clear the last digit While the desired charge weight is displayed press the ENTER button to dispense powder The dispenser will stop automatically when the selected charge weight is reached We recommend that the first several charges be placed back into the reservoir This allows the Gen 6 TM to fully stabilize and fill the charge tube with powder After a charge is dispensed the LCD will display CT 001 indicating the first charge for 2 seconds This is a count of the number of charges that have been dispensed Press the ENTER button again to dispense another charge at the selected weight in memory Important There are well over a hundred types of smokeless powder currently available The flow rate of each type will vary when dropped from the scale The scale and feed tube are designed to give the fastest drop time while still accurately controlling the charge weight Extensive testing has shown that a few powders may flow too quickly however and trickle past your selected charge weight If this occurs please install the supplied restrictor plug into the end of the powder feed tube This is most likely to occur with several large 5 granule stick type powders such as HS5OBMG and H4831SC The restrictor will slow the flow rate
5. and allow the scale to drop an exact charge with these few types without requiring that the scale be run slower and increase the drop time for the majority of powders used To install the restrictor simply hold on to the powder feed tube with one hand and thread the restrictor into the end of the tube with the other 6 To pause the dispenser while a charge is being dropped press the button Press the button again to resume charging 7 The dispenser will continue to drop the selected weight until it is changed To change the selected weight key in a new weight on the keypad and press the button The dispenser will drop the new selected charge weight 8 Auto Repeat To use the Auto Repeat function press the AUTO REPEAT key once and icon AUTO REPEAT will appear on LCD This icon tells you that you are in the auto repeat mode With the auto repeat mode on you should be able to enter in the desired charge weight and hit the key The scale will then drop the selected charge and beep flash AUTOO1 and then show the charge weight When the pan is emptied and returned to the scale the scale will zero out the pan and drop the same load again If the pan is not fully emptied the scale will show the weight in the pan and the Auto Repeat function will not work The pan must be emptied fully before the scale will drop another load The scale will repeat the same load until you either enter in a new load or exit the auto repeat fun
6. ction To exit the auto repeat function press the AUTO REPEAT key it will exit the auto repeat mode and AUTO REPEAT will disappear from the LCD Cleaning the Gen 6 Caution Do not turn unit upside down and shake as this could harm the load cell The cleaning procedure listed below may seem difficult but after you become familiar with the dispenser it is relatively easy The Gen 6 was designed to be sufficiently disassembled for thorough cleaning The Gen 6 must be cleaned after use or when changing the type of powder It is Strongly recommended that powder NOT be left in the powder dispenser when finished loading or when putting it away as you may forget what kind of powder was used last This is extremely dangerous To begin cleaning the dispenser lower the powder cleaning chute on the powder reservoir Be certain that you have a container under the chute to catch all the powder from the reservoir and powder box Lift the powder shut off door to allow the powder to flow out The cleaning brush can be used to remove any remaining powder When empty remove the reservoir tube and reservoir base by pressing the release button on top of the Dispenser Tilt the reservoir base away from the release button and lift it off the scale Place the rubber cap on the end of powder tube to prevent powder spillage Powder feed tube can be easily removed by inserting J shaped rod in small hole in the motor coupling as shown in Figure A
7. ickly and is accurate to or 0 1 grains It can be used as a complete powder dispensing system or as an electronic scale The compact Gen 6 is fast accurate and works with all types of smokeless powder Customer Driven Innovations With the introduction of the new Gen6 Compact Touch Screen Powder System we have incorporated the features our customers asked for and made this latest generation the best ever in powder systems An electronic interference shield to resist interference from cell phones and computers anti static and anti drift technology advanced touch screen and key pad less warm up time these are just a few of the features you requested and we have delivered in the Gen 6 Touch Screen Powder System A Set Up 1 Select a location for the Gen 6 that is level and stable It is 2 3 recommended that the Gen 6 be located away from a loading bench equipped with a reloading press Most benches are not heavy enough to prevent vibrations being transferred to the scale The scale should also be away from any source of air currents The Gen 6 is sensitive enough to have readings affected by any of these conditions Select the proper plug type and slide it onto the power adapter Plug the power adapter into a wall outlet and connect it to the dispenser Install the powder reservoir tube by pressing it into the top of the unit above the feed tube Remove end cap from powder feed tube
8. l not be correct and could be dangerous Be careful not be get powder between the platform and the scale body This can affect scale readings If powder does drop into this area carefully remove it with the supplied brush Do not attempt to remove the platform The proper power adapter must be used with the scale The power output of the adapter must be 9V DC and 500mA Congratulations on your purchase of the Lyman Gen 6 This is a precision piece of equipment and should be handled with care Before using the Gen 6 Powder Dispenser please read these instructions fully and become familiar with the key pads and other operating features listed in the diagrams If you have read the instructions and you still do not understand some of the operations call us at 1 800 22 LYMAN except AK HI CT and foreign who may call 860 632 2020 This operation manual should be kept with the Gen 6 TM at all times for easy reference Introduction Lyman s Gen 6 combines a Precision 1500 grain Electronic Powder Scale with an advanced Powder Dispenser and state of the art Touch Screen Technology into one easy to use unit The reduced footprint of the Gen 6 uses up to 50 less bench space than other powder systems but has all the accuracy of full sized models The design of the Gen 6 allows easy access for both right and left handed reloaders Its backlit touch screen display is simply to use and easy to read It dispenses powder qu
9. th Street Middletown CT 06457 CE APPROVED
Download Pdf Manuals
Related Search
instructions instructions synonym instructions not included movie instructions for 1040 2024 instructions for form 8962 instructions brp instructions meaning instructions in spanish translation instructions for 1040 instructions unclear meme instructions for form ss-4 instructions for schedule c instructions for form 720 instructions for 1040 2023 instructions for form 941 instructions for form 8949 instructions for box 12 on w2 instructions for form 1040 instructions for submitting certain i-589 instructions in writing adr instructions synonyme instructions to candidates instructions for prednisone dose pack
Related Contents
Xedio Browse User`s Manual OneTouch® UltraEasy® User Guide Austria Belgium Germany True Manufacturing Company TGU-3F User's Manual DRY WALL SANDER Instruction Manual PONCEUSE A BRAS Optoma Technology Panoview DP-MW3084A User's Manual Samsung SPF-85V User Manual Endbericht - Syspect - Carl von Ossietzky Universität Oldenburg FAX-8070P Guía de Configuración Rápida 取扱説明書参照 Copyright © All rights reserved.