Home
LPC2 CH1 User Manual
Contents
1. Label description LPC 2 CH1 is the full product name P N 225CH110V01001 is the part number 225 general code for LPC 2 product family CH1 short product name 10 year of code opening V denotes flush frame mounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades D C 10 10 is the date code 01 week and 10 year of production S N CH1 S9 1000000003 is the serial number CH1 short product name S9 user code test procedure e g Smarteh person xxx 10 year last two cyphers 00000003 current stack number previous module would have the stack number 00000002 and the next one 00000004 m Longo programmable controller LPC 2 CH1 special module SMART EH LIVING SYSTEMS 5 TECHNICAL SPECIFICATIONS Table 6 Technical specifications Power supply from MCU Interconnection connector type RJ12 6 6 Power consumption 2W RFID type EM4100 125kHz Manchester 64 read only Max reading distance RFID card inserted into CH1 slot Dimensions W x H x D 75 x 49 x 29 mm Weight 40 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position horizontal Transport and storage temperature 20 to 60 C Protection class IP 20 10 Longo programmable controller LPC 2 CH1 special module SMARTrTEH 3 LIVING SYSTEMS 6 CHANGES
2. SMARTEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 CH1 special module Version 2 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si Longo programmable controller LPC 2 CH1 special module SMARTEH LIVING SYSTEMS Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User Manual Document Version 002 July 1 2012 Longo programmable controller LPC 2 CH1 special module SMARTEH LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized representat
3. SMARTEH INSERT CARD Figure 1 LPC 2 CH1 special module Table 1 Technical data RFID reader RFID card slot Adjustable LED intensity LEDs for showing activated messages amp requests do not disturb room service 2 touch buttons for activating messages amp requests do not disturb room service OK J LED FAULT X LED Power LED Internal fault LED Internal built in buzzer e a Longo programmable controller LPC 2 CH1 special module SMARTEH LIVING SYSTEMS 3 OPERATION Operation of the CH1 module is also dependent on parameters received on RS485 communication channel If RFID card is inserted into slot reader tries to resolve RFID tag code If code is read successfully module activates status ilDNew and sends RFID code in ilDW1 ilDW3 status fields Code is send out until key card is removed from slot While ilDNew status is active and oOK or oFault is activated corresponding LED is turned on LED3 OK or LED4 fault respectively This state is sustained until key card is removed Each press on a TB1 or TB2 toggles status iDNDist or iRServ respectively By activating commands oOkLD oFaultLD oDNDist oRServ corresponding LED is turned on LED3 LED4 LED1 LED2 CH1 module LED s intensity can be adjusted from MCU application also By default their intensity is set to 75 While oEnInts status is active LED s intensity can be adjusted by changing oLdiInts
4. The following table describes all the changes to the document Date V Description 1 1 2012 002 CGP General update 1 10 2010 001 The initial version issued as LPC 2 CH1 module UserManual 11 Longo programmable controller LPC 2 CH1 special module SMARTER LIVING SYSTEMS 7 NOTES
5. 4 2 Mounting frame selection Frame suitable for CH1 module insertion should be modular one at least 3 gang wide Be careful to have corresponding flush mounting box provided on the place where module will be positioned Smarteh has verified following lines to be compatible with LPC 2 CH1 module e Bticino Living Light e Gewiss Playbus System e Vimar Plana Idea e Tem Modul Soft Modul Line e Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before installation verify compatibility of non listed frames Module housing has a fin on each side which can be easily removed with knife cutter or pliers This adaptation enables housing to be build in various frame formats with two different depths With regard to frame used you may remove fin for housing to fit in Ki N D gt N Figure 3 Fin removing lt Longo programmable controller LPC 2 CH1 special module SMARTER LIVING SYSTEMS 4 3 Mounting instructions Figure 4 Housing dimensions ki e Dimensions in millimeters All connections module attachments and assembling must be done while A module is not connected to the main power supply Module should not be mounted outdoors Several RFID panels should not be mounted close to each other Minimum distance to next panel is at least 30 cm This restriction also applies in case of mounting panels on both sides
6. parameter 3 1 Parameters If parameter is set to logical 1 is considered to be active enabled or set If parameter has logical value 0 is considered to be inactive disabled or cleared Parameter can be status or command Parameter as status means that CH1 module is sending information to MCU On the other hand command represents request from MCU to module iComm Normal state is 0 If set there is communication error or no communication established ilDNew When new RFID tag is recognized while inserted into CH1 slot this status is set active till RFID card is not removed from the CH1 slot iDNDist Active status denotes user has requested do not disturb message to be displayed LED1 iRServ Active status denotes user has requested room service message to be displayed LED2 oBuzz While this command is active buzzer is active oOK Command for authorization of RFID code oFault Command for rejecting authorization of RFID code oDNDist Command for activation of do not disturb message do not disturb LED1 is toggled oRServ Command for activation of room service request room service request LED2 is toggled oOkLD While this command is active OK LED4 is set oFaultLD While this command is active fault LED3 is set oEnlnts Enables changing LED s intensity together with oLdints value oLdints Command for setting LED intensity Only valid while oEnInts active ilDW1 Upper most sig
7. a 3 SPAAN tet Renee 3 AINS AE TON a 4 4 1 Connection SCNEME ccceccecccnsccccceeccesceescesccesceeccesceeseecescesceees 4 4 2 Mounting frame selecton ses 6 A NOURENS REENEN 7 AA Module ADCUING E 9 5 TECHNICAL SPECIFICATIONS ES ee en enen ac ce 10 SCANS so a AEE EE E EE 11 NOTES a E ee 12 jii _ Longo programmable controller LPC 2 CH1 special module SMARTrTEH D fh te Oh e e 2 nt Le Se LIVING SYSTEMS 1 DESCRIPTION LPC 2 CH1 RFID reader is intended to be used as presence registering device and key card holder Module also provides touch buttons TB for activating requested messages This messages are convenient to notify personnel e g occupied do not disturb Once a person has entered to the room the key card should be inserted to the CH1 card slot If card ID for correspondent room is valid several actions can be started e g room light and air conditioning switched on CH1 module features two TB with which customer is able to activate notification to the personnel One TB activates DO NOT DISTURB message and the other TB activates ROOM SERVICE request LPC 2 CH1 module can be modified on customer request custom front label push buttons changed LEDs added housing color Please contact manufacturer for more information Longo programmable controller LPC 2 CH1 special module SMARTrTEH LIVING SYSTEMS 2 FEATURES DO NOT ROOM DISTURB SERVICE
8. of the same wall Adequate shielding material and provisions could be used to avoid interference between panels Mounting of RFID panels into conductive metal frames is not allowed _ Longo programmable controller LPC 2 CH1 special module SMARTER LIVING SYSTEMS 1 Set the correct RS485 address S1 switch for LPC 2 CH1 refer to the Table 4 Connect interconnection cable to the connector K1 Max allowed tractive force is 30 N Put the LPC 2 CH1 in mounting frames u Cover LPC 2 CH1 with cover plate LPC 2 CH1 connects to the MCU unit on its RS485 port using interconnection cable When more special modules e g LPC 2 CR1 LPC 2 CH1 LPC 2 DP1 are connected to MCU splitter is also required e g SPL 2 Interconnection cable can be terminated on site considering wiring scheme bellow i Cable AWG26 4C flat i DEE Figure 5 i N 2 2 l mak Interconnection 8 d cable ICM x Rj12 6pin M Rj12 6pin M plastic notch faced pin faced NOTE Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard a DT K N wi oF a 2 nt Ay e a Longo programmable controller LPC 2 CH1 special module SMARTEH LIVING SYSTEMS 4 4 Module labeling Table 5 Labels Label 1 Label 2 LPC 2 CH1 P N 225CH110V01001 S N CH1 S9 1000000003 D C 01 10
9. ive Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired X Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards e EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 e LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia a Longo programmable controller LPC 2 CH1 special module SMARTrTEH LIVING SYSTEMS Index Longo programmable controller LPC 2 CH1 special module DESCRIPTION ee ae 1 RE 2 OPERATION
10. nificant third of RFID code iIDW2 Middle third of RFID code iIDW3 Lower least significant third of RFID code Longo programmable controller LPC 2 CH1 special module SMARTEH LIVING SYSTEMS 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme Future use module DP1 CH1 CR1 S1 _ Longo programmable controller LPC 2 CH1 special module SMARTTEH Table 2 K1 LIVING SYSTEMS K1 1 GND Ground K1 2 10 24 VDC Power supply input K1 3 RS485 A Data receive send line A K1 4 RS485 B Data receive send line B Table 3 LEDs amp Buttons On request active LED1 blue do not disturb bit ne request LED2 blue room service EE Off no request LED3 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED4 green OK J On RFID key standard OK and ID card number valid Off No tag in proximity LED5 red Communication On RS485 communication fault Off RS485 communication OK LED6 green Power supply On power supply OK Off power supply missing or power off TB1 do not disturb each press toggles request on off TB2 room service each press toggles request on off Table 4 S1 Been Switch 1 Switch 2 0 OFF OFF 1 OFF ON 2 ON OFF 3 ON ON e a _ Longo programmable controller LPC 2 CH1 special module SMARTER LIVING SYSTEMS
Download Pdf Manuals
Related Search
Related Contents
Rion 702124 Use and Care Manual User guide Conference phone Konftel 100 マルチ計測韓株式会社 Instructions Manual Bedienungsanleitung - Media Discopiu Rimini Bedienungsanleitung The radio for everyone HGST Travelstar IDK 250GB 5400rpm LETTRE SERVICE AT100 平成19年10月1日号(PDFファイル3.4メガバイト) Copyright © All rights reserved.