1. ALDF y CALE amp Each setpoint optional can be linked up via 4 alarms by default This can either be inserted at activated alarms ALI Y or deactivated alarms ALNI Y If LOGIC was selected logical links are available in the menu levels 06G and CON 1 Access to these two menu levels is via LOGIC at all other selected functions these two parameters are overleaped Via ON OFF the setpoints can be activated deactivated in this case the output and the setpoint display are set not set on the front of the device The parameters CAL CAL OF and CAL EN can only be used in accordance with the semi automatic calibration Chapter 9 Sensor alignment At CAL the relay switches during sensor calibration at CAL OF during offset calibration and at CAL EN during the calibration of the final value With P the selection is confirmed and the device changes into menu level Logic relay 1 L0G 1 Default OR la g fm mr v nol a And aRind P Here the switching behaviour of the relay is defined via a logic link the following schema describes these functions with inclusion of AL and AL 2 This parameter can only be selected if LOGIC was selected under REL am A1v A2 As soon as a selected alarm is activated the r
2. A Il l I 2 A yy ECP g AdE g SIRA g I extraction With this function the calculated value not the measuring value is shown in the display With NO no calculation is deposited With P the selection is confirmed and the device changes into menu level Sliding average determination AVG Default 1 0 oo S so S p Here the number of the meterings that need to be averaged is preset The time of averaging results of the product of measuring time SEC and the averaged metering AVG With the selection of AVG in the menu level BISPL the result will be shown in the display and evaluated via the alarms Zero point slowdown ZERO Default 00 JHC se At the zero point slowdown a value range around the zero point can be preset so the display shows a zero If e g 10 is set the display would show a zero in the value range from 10 to 10 below continue with 11 and beyond with 11 The maximum adjustable range of value is 99 Definite contstant value CONST Default 0 g Pg egege a El The constant value can be evaluated via the alarms or via the analog output like the current measurand The decimal place cannot be changed for this value and is taken over by the current measurand Like this a setpoint generator can be realised via the analog output by this value Furthermore it can be used for calculating
3. The initial value is adjusted from the smallest to the highest digit with A Y and confirmed digit per digit with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Overflow behaviour 0 FLOU Default EDGE rc a a a Li Agg A MAH a P To recognise and evaluate faulty signals e g by a controller the overflow behaviour of the analog output can be defined As overflow can be seen either EDGE that means the analog output runs on the set limits e g 4 and 20 mA or 70 0FF input value smaller than initial value analog output switches on e g 4 mA TO END higher than final value analog output switches on e g 20 mA If TO MN or TO MAX is set the analog output switches on the smallest or highest possible binary value This means that values of e g 0 mA 0 VDC or values higher than 20 mA or 10 VDC can be reached With P the selection is confirmed and the device changes into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group level 0UT 21 5 Setting up the device 5 4 5 Relay functions Jo P Mue Alarm relay 1 REL I Default AL 7 A A
4. R aS Dimension D physicai unit Version lele Switching points 0 no switching point 2 relay outputs Protection class 1 without keypad operation at the back 7 ip6s plug in terminal Voltage supply 115 VAC 5 230 VAC 6 10 30 VDC Measuring input 4 Jac current AC voltage TRMS Analog output 0 without 0 10 VDC 0 4 20 mA Sensor supply 0 without Please state physical unit by order e g A Contents 1 2 3 4 10 11 Brief descirption Assembly Electrical connection Description of function and operation 4 1 Programming software PM TOOL Setting up the device 5 1 Switching on 5 2 Standard parameterisation flat operation level Value assignment for the triggering of the signal input 5 3 Programming interlock RUN Activation Deactivation of the programming interlock or change into professional or flat operation level 5 4 Extended parametersation professional operation level 5 4 1 Signal input parameters INP Value assignment for the triggering of the signal input incl linearisation 5 4 2 General device parameters FLT Superior device functions like Hold Tara min max permanent setpoint value function nominal value function averaging brightness control as well as the control of the digital input and keyboard layout 5 4 3 Safety parameters COD Assignment of user and master code to lock or to receive access to define
5. the difference At this the constant value is substracted from the current measurand and the difference is evaluated in the alerting or by the analog output Thus regulations can be displayed quite easily Minimum constant value CON M Default 19999 pPegegregregE P The minimum constant value is adjusted from the smallest to the highest digit with the navigation keys A V and confirmed digit per digit with P A minus sign can only be adjusted on the highest digit After the last digit the display changes back into menu level 15 5 Setting up the device Menu level Parameterisation level Maximum constant value CON NA Default 99999 Pgegegelass The maximum constant value is adjusted from the smallest to the highest digit with the navigation keys A Y and confirmed digit per digit with P A minus sign can only be adjusted on the highest digit After the last digit the display changes back into menu level Display DISPL Default ACTUA AceuwA ST Ava o CARGA o Holid AUC conse COFF S P With this function the current measuring value min max value totaliser value or the process controlled hold value can be allocated to t
6. widespread detuning of the melt pressure sensors 12 5 Setting up the device Menu level Parameterisation level Setting up the physical unit UNIT Default NO of SosAs e888 ose v m F I One can choose between the above shown physical units It will be displayed on the 5th digit of the display Number of additional setpoints SPCT Default 00 a 30 additional setpoints can be defined to the initial value and final value so linear sensor values are not linearised Only activated setpoint parameters are displayed Display values for setpoints DIS 01 015 30 z o oO m l a I a P a PI gj P aly z P Under this parameter setpoints are defined according to their value At the sensor calibration like at final value offset one is asked at the end if a calibration shall be activated Analog values for setpoints INP 01 INP 30 B p P g P Plas e The setpoints are always preset according to the selected input signal A V The desired analog values can be freely parameterised in ascending order Device undercut DI UND Default 19999 5 2 ge g e 13 5 Setting up the dev
7. with P A minus sign can only be parameterized on the highest value digit After the last digit the display switches back to the menu level If SENS was selected as input option one can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value Setting up the start offset value of the measuring range OFFS Default 0 Bee eee es cee E L Enter the start offset value from the smallest to the highest digit with A Y and confirm each digit with P After the last digit the display switches back to the menu level If SENS was selected as input option one can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value 11 5 Setting up the device Menu level Parameterisation level Setting the decimal point DOT Default 0 mj mirn Ll LIL v m4 nin ra i BEE a ule v WH The decimal point on the display can be moved with A Y and confirmed with P The display then switches back to the menu level again Setting up the display time SEC Default 1 0 CREO COGS e Coo c
8. 0 0 seconds Rio Measuring error 0 1 AAC TRMS 0 5 of final value 0 5 AAC TRMS 0 5 of final value 0 50 VAC TRMS 0 5 of final value 0 10 VAC TRMS 0 5 of final value Digital input lt 2 4 V OFF 10 V ON max 30 VDC R 5 kQ Display time Accuracy Drift of temperature 100 ppm K Measuring time 0 1 10 0 seconds Measuring principle U F conversion Resolution approx 18 bit at 1 second measuring time 30 9 Technical data Analog output 0 4 20 mA burden 350 Ohm 0 10 VDC burden 10 kOhm 16 bit Switching outputs re Relay with change over contact 250 VAC 2 AAC 30 VDC 2 ADC Switching cycles 0 5 x 105 at contact load 0 5 x 10 mechanically Division according to DIN EN 50178 Characteristics according to DIN EN 60255 Power supply 230 VAC 10 50 60 Hz max 10 VA 10 30 VDC galv isolated max 4 VA Memory EEPROM Data life 2 100 years at 25 C Ambient conditions Working temperature 0 50 C Storing temperature 20 80 C Wheatering resistance relative humidity 0 80 on years average without dew EMV EN 61326 CE sign Conformity according to directive 2004 108 EG Safety standard According to low voltage directive 2006 95 EG EN 61010 EN 60664 1 31 10 Safety advices 10 Safety advices Please read the following safety advice and the assembly chapter 2 before installation and keep it for future reference Proper use The M2 14 device is designed for the evaluation and display o
9. 00 seconds Switching off delay TOF Default 000 POPE sa For limit value 1 one can preset a delayed switching off of 0 100 seconds Back to menu group level RET With P the selection is confirmed and the device changes into menu group level ALI The same applies for Ale to ALY 25 5 Setting up the device 5 4 7 Totaliser Volume metering Menu group level A P Mua State of totaliser TOTAL Default OFF OFF SEEAG ERAS P The totaliser realizes measurements on a time base of e g I h at this the scaled input signal is integrated by a time and steadily select STEAD or temporarily select TEMP saved Select the constant storage for consumption measurements and the quick storage for frequently filling processes During the constant storage STEAD the current sum value is saved at each totaliser reset Furthermore it is saved every 30 minutes in the not quick storage of the device If OFF was selected the function is deactivated With P the selection is confirmed and the device changes into menu level Time base T BASE Default SEC SEDA de AG de Under this parameter the time base of the measurement can be preset in seconds minutes o
10. 3 5 Setting up the device Menu level Parameterisation level Alarms for relay 2 COf e Default A 2 a si l Alt a Ae A ieJ jw P The allocation of the alarms to relay 2 happens via this parameter one alarm or a group of alarms can be chosen This parameter can only be selected if LOGIC was selected under REL 2 With P the selection is confirmed and the device changes into menu level Back to menu group level RET With P the selection is confirmed and the device changes into menu group level REL Depedency of alarm 1 ALRN I Default ACTUA Kua old A E EEF P The dependency of alarm 1 can be related to special functions in detail these are the current measurand the min max value the totaliser value sum value the sliding average value the constant value or the difference between the current measurand and the constant value If HOLD was selected the alarm is hold and processed just after deactivation of HOLD EHTER causes the dependency either by pressing the O key on the front of the housing or by an external signal via the digital input With P the selection is confirmed and the device changes into menu level Example By usi
11. C or 230 VAC L 4 Description of function and operation 4 Description of function and operation Operation The operation is divided into three different levels Menu level delivery status This level is designed for the standard settings of the device Only menu items which are sufficent to set the device into operation are displayed To get into the professional level run through the menu level and parameterise PROF under menu item RUN Menu group level complete function volume Suited for complex applications as e g linkage of alarms setpoint treatment totaliser function etc In this level function groups which allow an extended parameterisation of the standard settings are availabe To leave the menu group level run through this level and parameterise ULOC under menu item RUN Parameterisation level Parameters deposited in the menu item can here be parameterised Functions that can be changed or adjusted are always signalised by a flashing of the display Settings that are made in the parameterisation level are confirmed with P and thus saved By pressing the O key zero key it leads to a break off of the value input and to a change into the menu level All adjustments are saved automatically by the device and changes into operating mode if no further key operation is done within the next 10 seconds og re eo Change to parameterisation level and deposited values Menu level Keys for up and down navigation in
12. User manual M2 Alternating voltage Alternating current signal rms value TRMS 0 50 VAC 0 10 VAC 0 1 AAC 0 5 AAC a Technical features e red display of 19999 99999 Digits optional green orange blue e installation depth 70 mm without plug in terminal min max memory e 30 adjustable supporting points display flashing at threshold value exceedance undercut e digital input for triggering of Hold Tara permanent min max value recording e volume metering totaliser e mathematical functions like reciprocal value square roots squaring or rounding e setpoint generator e sliding averaging e brightness control programming interlock via access code e protection class IP65 at the front e pluggable screw terminal e optional galvanic insulated digital input or analog output optional 2 relay outputs accessories PC based configuration kit PM TOOL incl CD and USB adapter for devices without keypad and for a simple adjustment of standard devices M2_14GB pdf update 12 10 2015 96x48 Identification STANDARD TYPES ORDER NUMBER AC current AC voltage M2 1VR5B 0004 570CD Housing size 96x48 mm M2 1VR5B 0004 670CD Options breakdown of order code Basic type M2 Installation depth 89 mm incl plug in terminal Housing size B96xH48xT70 mm Display colour Blue Green Red Yellow Number of digits 5 digit Digit height 14 mm Digital input without one lt Ea B
13. a reset can be carried out to the default values The following procedure should be used e Switch off the power supply e Press P button e Switch on voltage supply and press P button until is shown in the display With reset the default values of the program table are loaded and used for subsequent operation This sets the unit back to the state in which it was supplied Caution All application related data are lost 27 7 Alarms Relays 7 Alarms Relays This device has 4 virtual alarms that can monitor one limit value in regard of an undercut or exceedance Each alarm can be allocated to an optional relay output S1 S2 furthermore alarms can be controlled by events like e g Hold or min max value Function principle of alarms relays deactivated instantaneous value min max value hold value totaliser value sliding average value constant value difference between instantaneous value and constant value or an activation via the digital input Threshold limit value of the change over Broadness of the window between the switching thresholds Operating current quiescent current Alarms Operating current By operating current the alarm S1 S2 is off below the threshold and on on reaching the Threshold threshold On ace ek errs rey on Se e I L HA4 Ag gt S Off Display Hysterisis kt ae Quiescent current By quiescent current the alarm S1 S2 is on below the thres
14. alog output OUTPT Default ACTUA ACE AW allt TARH Alu d IFF A Ho A E FIF a P The analog output signal can refer to different functions in detail these are the current measurand the min max value the totaliser function sum function the constant value or the difference between current measurand and constant value If HOLD was selected the signal of the analog output will be kept It can be continued processing after a deactivation of HOLD With P the selection is confirmed and the device changes into menu level Selection analog output QUT RA Default 4 20 mM mj l mi a LI Fy Ui 2 YI le1G a P Three output signals are available 0 10 VDC 0 20 mA and 4 20 mA Select the desired signal with this function Setting the final value of the analog output QUT EN Default 10000 gP gege gegen The final value is adjusted from the smallest to the highest digit with A Y and confirmed digit per digit with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level 20 5 Setting up the device Menu level Parameterisation level Setting the initial value of the analog output QUT OF Default 00000 g P gege 2 g P
15. an excisting limit value monitoring and the current measurement will not be influenced by this If NO is selected the navigation keys are without any function in the operation mode 17 5 Setting up the device Menu level Parameterisation level Special function O key TAST 4 Default NO oe lt gt lt gt P For the operation mode special functions can be deposited on the O key Activate this function by pressing the key With TARA the device is set temporarily on a parameterised value The device acknowledges the correct taring with showing ooooo in the display SET TA adds a defined value on to the currently displayed value Via TOTAL the current value of the totaliser can be displayed for approx 7 seconds after this the device switches back on the parameterised display value If TOT RE was deposited the totaliser can be set back by pressing the navigation keys A Y the device acknowledges this with showing oooo0 in the display EHT RE deletes the min max memory If HOLD has been selected the moment can be hold constant by pressing the O key and is updated by releasing the key Advice HOLD is activated only if HOLD was selected under parameter DISPL ACTUA shows the measuring value for approx 7 seconds after that the device switches back on the para
16. arameters again Master code 4 digit number combination free available A CODE Default 1234 Fee sa All parameters can be unlocked with this code after LOC has been activated under menu item RUN By pressing P for 3 seconds in operation mode the display shows CODE and enables the user to reach all parameters by entering the ACODE Under RUN the parameterisation can be activated permanently by selecting ULOC or PROF thus at an anew pushing of P in operation mode the code needs not to be entered again 5 Setting up the device 5 3 Programming interlock RUN Menu level Parameterisation level Activation deactivation of the programming lock or completion of the standard parameterisation with change into menu group level complete function range RUN Default ULOC poe ir a PoF P LIL L v LIL vy I With the navigation keys A V choose between the deactivated key lock ULOC works setting and the activated key lock LOC or the change into the menu group level PROF Confirm the selection with P After this the display confirms the settings with and auto matically switches to operating mode If LOC was selected the keyboard is locked To get back into the menu level press P for 3 seconds in operating mode Now enter the CODE work
17. ator For calibration problems or 30 seconds holding time I Current measuring range value I eg 0 061 For minimum 1 measuring cycle or with actuator Switch off switch on optional switching MI output e g 7 132 For minimum 1 measuring cycle minimum 1s or maximum per actuator J f Current measuring range value on For calibration problems For minimum 1 measuring cycle or 30 seconds holding minimum 1s or maximum per actuator time gt Optional switch off switching output and display m for minimum 1 measuring cycle or minimum 1s holding time Back to regular operation mode after Back to regular operation mode 1s or 1 measuring cycle 29 9 Technical data 9 Technical data 96x48x70 mm BxHxD 96x48x89 mm BxHxD incl plug in terminal Panel cut out 92 0798 x 45 0796 mm Wall thickness up to 10 mm screw elements PC polycarbonate black UL94V 0 EPDM 65 Shore black standard IP65 front IPOO back side Fixing Material Sealing material Protection class Weight approx 200 g Connection plug in terminal wire cross section up to 2 5 mm Display Digit height 14mm Segment colour red optional green orange or blue Range of display 19999 to 99999 Setpoint one LED per setpoint Overflow Underflow horizontal bars at the top horizontal bars at the bottom 0 1 to 1
18. d parameter such as analog output and alarms etc 5 4 4 Analog parameters QUT Analog outpur functions 5 4 5 Relay functions REL Parameter for setpoint definition 5 4 6 Alarm parameters AL1 ALY Actuator and dependencies of the alarms 5 4 7 Totaliser Volume metering TOT Parameter for calculation of the sum function Reset to factory settings Reset parameters onto the delivery state Alarms Relays Functional principle of the switching outputs Sensor aligment Diagram of functional sequences for sensors with existing adjustable resistor Technical data Safety advices Error elimination N NN OO OO FR WO ND So 11 11 14 19 20 22 24 26 27 28 29 30 32 33 1 Brief description 1 Brief description The panel meter instrument M2 14 is a 5 digit device for AC current AC voltage signals TRMS and a visual threshold value monitoring via the display The configuration happens via four keys at the front or by the optional PC software PM TOOL The integrated programming interlock prevents unrequested changes of parameters and can be unlocked again with an individual code Optional the following functions are available a digital input for triggering of Hold Tara aswall as one analog output for further evaluating in the unit With help of the galvanic isolated setpoints optional free adjustable limit values can be controlled and reported to a superior master display The el
19. e by applying the voltage supply Before check once again that all electrical connections are correct Starting sequence For 1 second during the switching on process the segment test 8 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the starting sequence the device switches to operation display mode 5 2 Standard parameterisation Flat operation level To parameterise the display press the P key in operating mode for 1 second The display then changes to the menu level with the first menu item TYPE Menu level Parameterisation level Selection of the input signal TYPE Default SE SOU a v esou 4 SEDU 4 SESA SEAS P Available as measuring input options are 0 50 VAC 0 10 VAC or 0 5 AAC 0 1 AAC signals as works calibration without application of the sensor signal and SE SOV SEJOV SE SA and SE 1A as sensor calibration with the sensor applied Select with A Y and confirm the selection with P Setting the end value of the measuring range END Default 10000 g P pP gP gePg 7 32 L Set the end value from the smallest to the highest digit with A Y and confirm each digit with P A minus sign can only be parameterized o
20. ectrical connection is done via plug in terminals on the back side Selcetable functions like e g the recall of the min max value an averaging of the measuring signals a nominal presetting or setpoint presetting a direct threshold value regulation during operation mode and further measuring setpoints for linearisation complete the modern device concept 2 Assembly 2 Assembly Please read the Safety advices on page 32 before installation and keep this user manual for future reference Z Gap for physical unit W After removing the fixing elements insert the device Check the seal to make sure it fits securely Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to tighten them another half a turn VNS CAUTION The torque should not exceed 0 1 Nm The dimension symbols can be exchanged before installation via a channel on the side 3 Electrical connection 3 Electrical connection Type M2 1VR5B 0004 470CD supply of 115 VAC Type M2 1VR5B 0004 570CD supply of 230 VAC Type M2 1VR5B 0004 670CD supply of 10 30 VDC COMDEOOODAO 0 10 VAC a 1 0 50 VAC S1 S2 Digital input Option N oe B ogogo Relay option ree 0 10 VDC 0 4 20 mA Analog output Option M2 with digital input and external voltage supply source Digital input 10 30 VDC a 10 30 VDC or 115 VA
21. elay operates Equates to operating current principle ma A1vA2 A1A A2 The relay operates only if no selected alarm is active Equates to quiescent current principle And A1 Aa2 The relay operates only if all selected alarms are active m Alin g A1NA2 A1v A2 As soon as a selected alarm is not activated the relay operates With P the selection is confirmed and the device changes into menu level 22 5 Setting up the device Menu level Parameterisation level Alarms for relay 1 C0 1 Default 7 7 i a a amag 4 AI v A Wo 2 JH a P The allocation of the alarms to relay 1 happens via this parameter one alarm or a group of alarms can be chosen This parameter can only be selected if LOGIC was selected under REL 1 With P the selection is confirmed and the device changes into menu level Alerting relay 2 REL 2 Default Al 2 rye lA oo g DF CALEA Each setpoint optional can be linked up via 4 alarms by default This can either be inserted at activated alarms ALI Y or deactivated alarms ALNI Y If LOGIC was selected logical links are available in the menu level L0G 7 and CON 1 Access to these two menu levels is via LOGIC at all other selected functions these two
22. etting up the display time SEC Default 1 0 c ri a The display time is set with A Y The display moves up in increments of 0 1 up to 1 second and in increments of 1 0 up to 10 0 seconds Confirm the selection by pressing the P button The display then switches back to the menu level again Selection of analog output OUT RA Default 4 20 m A mj lA Three output signals are available 0 10 VDC 0 20 mA and 4 20 mA with this function the demanded signal is selected Setting up the final value of the analog output OUT EN Default 10000 p l pa m l ge B g e gege fi Li The final value is adjusted from the smallest digit to the highest digit with A Y and digit by digit confirmed with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Setting up the initial value of the analog output QUT OF Default 00000 my PJ 5 mj l e gy B g e P p P The final value is adjusted from the smallest digit to the highest digit with A VY and digit by digit confirmed with P A minus sign can only be parameterised on the highest digit After the last digit the device changes back into menu level Threshold values limits L 1 Defau
23. f sensor signals Danger Careless use or improper operation can result in personal injury and or cause damage to the equipment Control of the device The panel meters are checked before dispatch and sent out in perfect condition Should there be any visible damage we recommend close examination of the packaging Please inform the supplier immediately of any damage Installation The M2 14 device must be installed by a suitably qualified specialist e g with a qualification in industrial electronics Notes on installation e There must be no magnetic or electric fields in the vicinity of the device e g due to transformers mobile phones or electrostatic discharge e The fuse rating of the supply voltage should not exceed a value of 6A N B fuse e Do not install inductive consumers relays solenoid valves etc near the device and suppress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes e Keep input output and supply lines separate from one another and do not lay them parallel with each other Position go and return lines next to one another Where possible use twisted pair So you receive best measuring results e Screen off and twist sensor lines Do not lay current carrying lines in the vicinity Connect the screening on one side on a suitable potential equaliser normally signal ground e The device is not suitable for installation in areas where there is a risk
24. he display With P the selection is confirmed and the device changes into menu level Brightness control LIGHT Default 10 4 i Se v The brightness of the display can be adjusted in 16 levels from 00 very dark to 15 very bright via this parameter or alternatively via the navigation keys from the outside During the start of the device the level that is deposited under this parameter will always be used even though the brightness has been changed via the navigation keys in the meantime Display flashing FLASH Default NO a v ALi py ALSH LJH ALA A display flashing can be added as additional alarm function either to single or to a combination of off limit condition With NO no flashing is allocated 16 5 Setting up the device Menu level Parameterisation level Assignment deposit of key functions TAST Default NO uf Oo lt lt gt lt j lt gt lt gt lt gt gt gt gt For the operation mode special functions can be deposited on the navigation keys A Y in particular this function is made for device
25. hold and switched off on Threshold reaching the threshold nig amen a ee ee a tier ats activated lt q a yo vale Off Display Hysterisis i input Switching on delay The switching on delay is activated via an 10 alarm and e g switched 10 seconds after Switching threshold reaching the switching threshold a short 0 term exceedance of the switching value Time s 5 does not cause an alarm respectively does not cause a switching operation of the relay The switching off delay operates in the same way keeps the alarm the relay switched longer for the parameterised time Alarm switching on delay 10 s Time s 28 8 Sensor alignment offset final value 8 Sensor alignment offset final value The device is equipped with a semi automatic sensor calibration SE 10 SESOV SEIA SESA A switching output operates the trimming resistor which exists in some sensors An adjustment of offset and final value takes place after which the sensor can be used directly Depending on parameterisation the calibration can be realized via the 4th key or via the digital input It is possible to key during the calibration steps So reference signals can be connected manually However the calibration will be interrupted after 30 seconds Press actuator for minimum 3 seconds pm Activate optional switching output For minimum 1 measuring cycle minimum 1s or maximum per actu
26. ice Menu level Parameterisation level Display overflow DI OUE Default 99999 A P DgegpTn With this function the display overflow can be defined on a definite value Back to menu group level RET With P the selection is confirmed and the device changes into menu group level INP 5 4 2 General device parameters Display time DISEC Default 01 0 a m mj The display is set up with A Y Thereby it switches up to 1 second in increments of 0 1 seconds and up to 10 0 seconds in increments of 1 0 With P the selection is confirmed and the device changes into menu level Rounding of display values ROUND Default 00001 ltl Gooas 00D ME E a LALA LI L v CG This function is for instable display values where the display value is changed in increments of 1 5 10 or 50 This does not affect the resolution of the optional outputs With P the selection is confirmed and the device changes into menu level 14 5 Setting up the device Menu level Parameterisation level Arithmetic ARITH Default NO
27. it has found an error in the 7 segment display configuration memory Perform a reset on the default values and reconfigure the unit according to your application Program numbers for parameterising e Programming lock is activated of the input are not accessible Enter correct code ERRI lights up in the 7 segment display Please contact the manufacturer if errors of this kind occur The device does not react as e If you are not sure that the device has been expected parameterised before then follow the steps as written in chapter 6 and set it back to its delivery status 33 M2_14GB pdf update 12 10 2015
28. lt 2000 J2a052 020 O ge This value defines the threshold that activates deactivates an alarm 5 Setting up the device Menu level Parameterisation level Hysteresis for limit values 44 1 Default 00000 Jegag8peg sa The delayed reaction of the alarm is the difference to the threshold value which is defined by the hysteresis Function for threshold value undercut exceedance FU 1 Default HIGH a ry P A limit value undercut is selected with LOUU for LOW lower limit value a limit value exceedance with HIGH for HIGH higher limit value If e g limit value 1 is on a threshold level of 100 and allocated with function HIGH an alarm is activated by reaching of the threshold level If the threshold value was allocated to LOU an alarm will be activated by undercutting the threshold value as long as the hysteresis is Zero User code 4 digit number combination free available U CODE Default 0000 Ae geese te If this code was set gt 0000 all parameters are locked for the user if LOC has been selected before under menu item RUN By pressing P for 3 seconds in operation mode the display shows CODE The U CODE needs to be entered to get to the reduced number of parameter sets The code has to be entered befor each parametrisation until the A CODE Master code unlocks all p
29. meterised display value The same goes for AVG here the sliding average values will be displayed A sensor calibration is done by triggering the digital input via SE CAL the flow diagram is shown in Chapter 9 The constant value CONST can be recalled via the digital input or changed digit per digit At AL 7 AL 4 an output can be set and therewith e g a setpoint adjustment can be done If NO is selected the O key is without any function in the operation mode aa lt gt lt gt lt gt lt gt Special function digital input DIG IN Default NO EIEE A E oe lt gt lt gt lt lt gt lt gt lt gt moa lt lt gt L lt gt lt gt lt gt In operation mode the above shown parameter can be laid on the optional digital input too Function description see TAST 4 Back to menu group level RET With P the selection is confirmed and the device changes into menu group level FLT 18 5 Setting up the device 5 4 3 Safety parameters Menu group level User code U CODE Default 0000 o B g g e Via this code reduced sets of parameters can be set free A change of the U CODE can be done via the correct input of the A COBE master c
30. n the highest value digit After the last digit the display switches back to the menu level If SENS was selected as input option one can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value Setting the start offset value of the measuring range OFFS Default 0 z R B2g5g595R8 FOF ge Enter the start offset value from the smallest to the highest digit with A Y and confirm each digit with P After the last digit the display switches back to the menu level If SENS was selected as input option one can only select between NOCA and CAL With NOCA only the previously set display value is taken over and with CAL the device takes over both the display value and the analogue input value 5 Setting up the device Menu level Parameterisation level Setting the decimal point DOT Default 0 mi Li mae LIL mj ra mj A HERRAN E ule v v The decimal point on the display can be moved with A Y and confirmed with P The display then switches back to the menu level again S
31. ng the maximum value ALARN I MAX VA in combination with a threshold monitoring FU 1 HIGH an alarm confirmation can be realised Use the navigation keys or the 4th key for confirmation 24 5 Setting up the device Menu level Parameterisation level Threshold values limit values L 7 Default 2000 o P g e g e g P The limit value defines the threshold that activates deactivates an alarm Hysteresis for threshold values 9 1 Default 00000 o e g 2 g g The delayed reaction of the alarm is the difference to the threshold value which is defined by the hysteresis Function for threshold value undercut exceedance FU 1 Default HIGH a a v u v P A limit value undercut is selected with LOUU for LOW lower limit value a limit value exceedance with HIGH for HIGH higher limit value If e g limit value 1 is on a threshold level of 100 and allocated with function HIGH an alarm is activated by reaching of the threshold level If the threshold value was allocated to LOW an alarm will be activated by undercutting the threshold value as long as the hysteresis is zero Switching on delay TQN 1 Default 000 m a FIGS Fe For limit value 1 one can preset a delayed switching on of 0 1
32. ode Master code A CODE Default 1234 qe ee v By entering A CODE the device will be unlocked and all parameters are released Release lock analog output parameter OUT LE Default ALL a F Al v v v Analog output parameter can be locked or released for the user EN OF the initial or final value can be changed in operation mode OUT EO the output signal can be changed from e g 0 20 mA to 4 20 mA or 0 10 VDC ALL analog output parameters are released NO all analog output parameters are locked Release lock alarm parameters AL LEU Default ALL E ALE COR This parameter describes the user release user lock of the alarm a NO fy LIMIT here only the range of value of the threshold values 1 4 can be changed ALRM L here the range of value and the alarm trigger can be changed ALL all alarm parameters are released NO all alarm parameters are locked 5 Setting up the device Menu level Parameterisation level Back to menu group level RET Selection reference of an
33. of explosion e Any electrical connection deviating from the connection diagram can endanger human life and or can destroy the equipment e The terminal area of the devices is part of the service Here electrostatic discharge needs to be avoided Attention High voltages can cause dangerous body currents e Galvanic isolated potentials within one complex need to be placed on an appropriate point normally earth or machines ground So a lower disturbance sensibility against impacted energy can be reached and dangerous potentials that can occur on long lines or due to faulty wiring can be avoided 32 11 Error elimination 11 Error elimination i 1 4 5 Error description Measures S The unit permanently indicates e The input has a very high measurement overflow check the measuring circuit e With a selected input with a low voltage signal it is only connected on one side or the input is open e Not all of the activated setpoints are parameterised Check if the relevant parameters are adjusted correctly The unit permanently shows e The input has a very low measurement check underflow the measuring circuit e With a selected input with a low voltage signal it is only connected on one side or the input is open Not all of the activated setpoints are parameterised Check if the relevant parameters are adjusted correctly The word HELP lights up in the e The un
34. oon 4 e The display time is set with A Y The display moves up in increments of 0 1 up to 1 second and in increments of 1 0 up to 10 0 seconds Confirm the selection by pressing the P button The display then switches back to the menu level again Rescaling the measuring input values ENDA Default 10000 g P g Pg eP oigo With this function rescale the input value of e g 4 9 AAC works setting without applying a measuring signal If sensor calibration has been selected these parameters are not available Rescaling the measuring input values OFFA Default 0 3 gP geg PH TP With this function rescale the input value of e g 0 1 AAC works setting without applying a measuring signal If sensor calibration has been selected these parameters are not available Setting up the tare offset value TARA Default 0 D Pape gegreg 40 The given value is added to the linearized value In this way the characteristic line can be shifted by the selected amount Setting up the balance point ADJ PT Default 08000 goe pegegegp 22 i The balance point for the final value can be chosen from the measuring range by SE OV with 0 10 V or SEIA with 0 1 Ain The preset 80 000 result from the
35. parameters are overleaped Via ON OFF the setpoints can be activated deactivated in this case the output and the setpoint display are set not set on the front of the device The parameters CAL CAL OF and CAL EN can only be used in accordance with the semi automatic calibration Chapter 8 Sensor alignment At CAL the relay switches during sensor calibration at CAL OF during offset calibration and at CAL EN during the calibration of the final value With P the selection is confirmed and the device changes into menu level Logic relay 2 106 2 Default OR or a nor a Ang nAlnid ai Here the switching behavior of the relay is defined via a logic link the following schema describes these functions with inclusion of AL and AL 2 This parameter can only be selected if LOGIC was selected under REL A1v A2 As soon as a selected alarm is activated the relay operates Equates to operating current principle A1v A2 A1AA2 The relay operates only if no selected alarm is active Equates to quiescent current principle A1lAa2 The relay operates only if all selected alarms are active m A14A2 Alv A2 As soon as a selected alarm is not activated the relay operates With P the selection is confirmed and the device changes into menu level 2
36. r hours Totaliser factor FACTO Default E0 TE a ED amp EB a P At this the factor 1E0 1E6 respectively the divisor for the internal calculation of the measuring value is assigned Setting up the decimal point for the totaliser TOT DT Default 0 Li LALI LLI v v mmm la a a vy v The decimal point of the device can be adjusted with the navigation keys A Y With P the selection is confirmed and the device changes into menu level 26 6 Reset to default values Menu level Parameterisation level Totaliser reset TOT RE Default 00000 FeFqg2g2qF8 4a The reset value is adjusted from the smallest to the highest digit with the navigation keys 4 Y and digit per digit confirmed with P After the last digit the display switches back to the menu level The activator for the reset is parameter driven via the 4t key or via the optional digital input Back to menu group level RET With P the selection is confirmed and the device changes into menu group level T0T Programming interlock run Menu group level I lulnl P Description see page 10 menu level RUN fel 6 Reset to default values To return the unit to a defined basic state
37. s setting 123 4 that appears using A V plus P to unlock the keyboard FAIL appears if the input is wrong To parameterise further functions PROF needs to be set The device confirms this setting with and changes automatically in operation mode By pressing P for approx 3 seconds in operation mode the first menu group INP is shown in the display and thus confirms the change into the extended parameterisation It stays activated as long as ULQC or LOC is entered in menu group RUN 10 5 Setting up the device 5 4 Extended parameterisation Professional operation level 5 4 1 Signal input parameters Menu group level ina P P Menu level Parameterisation level Selection of the input signal TYPE Default SE SOU a v ESDU 4 GEODO 4 SESA SEAS f Available as measuring input options are 0 50 VAC 0 10 VAC or 0 5AAC 0 1 AAC signals as works calibration without application of the sensor signal and SE SOV SE7OV SE 5A and SE 1A as sensor calibration with the sensor applied Select with A Y and confirm the selection with Setting the end value of the measuring range END Default 10000 Bee e88508 H e L Set the end value from the smallest to the highest digit with A Y and confirm each digit
38. s in housing size 48x24mm which do not have a 4th key O key If the min max memory is activated with EHTR all measured min max values are saved during operation and can be recalled via the navigation keys The values get lost by restart of the device If the threshold value correction LiJ2 or Li34 is choosen the values of the threshold can be changed during operation without disturbing the operating procedure With TARA the device is tared to zero and saved permanently as offset The device confirms the correct taring by showing ooo00 in the display SET TA switches into the offset value and can be changed via the navigation keys A W Via TOTAL the current value of the totaliser can be displayed after this the device changes back on the parameterised display value If TOT RE was deposited the totaliser can be set back by pressing the navigation keys A Y the device acknowledges this with showing oo0000 in the display The configuration of EXT RE deletes the min max memory Under ACTUA the measurand is shown after this the display returns to the parameterised display value If A8S UA absolute value was selected the display shows the value that has been measured since voltage connection without consideration of a previous taring Via selection L7 7 L1 1 2 LI 1 3 L1 1 4 threshold values can be addressed via the navigation keys they can be changed digit per digit or taken over by pushing the P key The adjustment is taken over directly
39. the menu level Change into operation mode To confirm the changes made at the parameterisation level 4 Description of function and operation Function chart Standard parameterisation Flat operation level Operation mode P 0 run PROF P Menu level TUN ULOL P Input break N E 0 gt 10s IP or i S L Parameter A Y level j Underline P Takeover lO stop lA Value selection iv Value selection 4 1 Parameterisation software PM TOOL Extended parameterisation professional operation level Operation mode Menu group level Lg OJ Input break P N oF gt 10s B Menu level n O P N or P Parameter E Few level ry v Part of the PM TOOL are the software on CD and an USB cable with device adapter The connection happens via a 4 pole micromatch plug on the back side of the device to the PC side the connection happens via an USB plug System requirements PC incl USB interface Software Windows XP Windows VISTA With this tool the device configuration can be generated omitted and saved on the PC The parameters can be changed via the easy to handle program surface whereat the operating mode and the possible selection options can be preset by the program 5 Setting up the device 5 Setting up the device 5 1 Switching on Once the installation is complete start the devic